| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC MAIRAKATA P O GARBETA DIST PASCHIM MEDINIPUR 721127 | GARBETA | PASCHIM MEDINIPUR | WEST BENGAL | 721127 | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹46.0 L+₹1.2 L (2.65%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹46.2 L+₹1.4 L (3.03%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest | |
| 4 | L4₹46.3 L+₹1.5 L (3.43%)Rejected-Finance GR 8 ADDA BUILDING 1ST FLOOR CITY CENTRE DURGAPUR 16 | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | L4 | Rejected-Finance 4th lowest |
| Sl No | Description | Qty | Unit | RIK ENTERPRISE L2 | RS SYSTEMS AND PROJECTS L3 | R.K.ENTERPRISE L1 | DURGAPUR POWER L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling the existing E.I. work incl existing defective , non functioning Panels , PBDB, LBDB, Main Switch etc by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC. | 1 | Item | 2,554 ₹2,554 Lowest | 2,554 ₹2,554 Lowest | 8,641 ₹8,641 | 5,000 ₹5,000 |
| 2.00 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand/ L&T/ ABB/ Havells/ as per direction of EIC) of the following sizes as to GS. (Normal power- 2nos, DG power-1 no) 8way Enclosure upto 160 Amp | 3 | Each | 11,217 ₹33,651 Lowest | 11,217 ₹33,651 Lowest | 11,217 ₹33,651 Lowest | 13,521 ₹40,563 |
| 3.00 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand/ L&T/ ABB/ Havells/ as per direction of EIC) as to GS. 6 way Enclosure (for DG Power only) | 4 | Each | 3,679 ₹14,716 | 3,679 ₹14,716 | 3,679 ₹14,716 | 2,689 ₹10,756 Lowest |
| 3.01 | 8 way Enclosure (for Normal Power only) | 10 | Each | 4,404 ₹44,040 | 4,404 ₹44,040 | 2,652 ₹26,520 Lowest | 3,569 ₹35,690 |
| 4.00 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand/ L&T/ ABB/ Havells/ as per direction of EIC) as to GS
2+12 way Enclosure | 25 | Each | 2,325 ₹58,125 | 2,325 ₹58,125 | 926 ₹23,150 Lowest | 2,533 ₹63,325 |
| 5.00 | Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment (Make- Legrand/ L&T/ ABB/ Havells/ as per direction of EIC) as to GS.
8 way VTPN | 3 | Each | 1,126 ₹3,378 | 1,126 ₹3,378 | 700 ₹2,100 Lowest | 1,523 ₹4,569 |
| 5.01 | 8 way HTPN | 10 | Each | 878 ₹8,780 | 878 ₹8,780 | 578 ₹5,780 Lowest | 1,235 ₹12,350 |
| 5.02 | 6 way HTPN | 4 | Each | 716 ₹2,864 | 716 ₹2,864 | 421 ₹1,684 Lowest | 895 ₹3,580 |
| 6.00 | Supplying and fixing 415 V four pole MCCB of breaking capacity 25kA/35kA with fixed thermal and fixed magnetic/adjustable thermal and fixed magnetic setting in existing DBs/ enclosure and necessary connection (Make- Legrand/ L&T/ ABB/ Havells/ as per direction of EIC) as to GS.
100 Amp | 1 | Each | 7,500 ₹7,500 | 7,500 ₹7,500 | 7,500 ₹7,500 | 5,890 ₹5,890 Lowest |
| 6.01 | 125 Amp | 2 | Each | 8,546 ₹17,092 Lowest | 8,546 ₹17,092 Lowest | 8,546 ₹17,092 Lowest | 9,564 ₹19,128 |
Tender Value
Refer Docs
EMD Value
₹76,015
Closing Date
5 Mar 2024, 10:55 amClosed
Executive Engineer, PWDte
Bankura
Electrical Repairing and Renovation works at Simla BPHC Khatra.
2024_WBPWD_670993_1
WBPWDTE/EE/BED/NIQ_80/Q of 2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Wise
60 days
Simla BPHC Khatra
Please refer Tender documents.
3 documents required · 3 mandatory
₹76,015
9 Oct 2026
20 Feb 2024
7 Mar 2024
20 Feb 2024
5 Mar 2024
20 Feb 2024
Amount
Dismantling the existing E.I. work incl existing defective , non functioning Panels , PBDB, LBDB, Main Switch etc by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC.
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand/ L&T/ ABB/ Havells/ as per direction of EIC) of the following sizes as to GS. (Normal power- 2nos, DG power-1 no) 8way Enclosure upto 160 Amp
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand/ L&T/ ABB/ Havells/ as per direction of EIC) as to GS. 6 way Enclosure (for DG Power only)
8 way Enclosure (for Normal Power only)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Make- Legrand/ L&T/ ABB/ Havells/ as per direction of EIC) as to GS 2+12 way Enclosure
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment (Make- Legrand/ L&T/ ABB/ Havells/ as per direction of EIC) as to GS. 8 way VTPN
8 way HTPN
6 way HTPN
Supplying and fixing 415 V four pole MCCB of breaking capacity 25kA/35kA with fixed thermal and fixed magnetic/adjustable thermal and fixed magnetic setting in existing DBs/ enclosure and necessary connection (Make- Legrand/ L&T/ ABB/ Havells/ as per direction of EIC) as to GS. 100 Amp
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection (Make- Legrand/ L&T/ ABB/ Havells/ as per direction of EIC), as to GS. 415 V, 63A FP
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Make- Legrand/ L&T/ ABB/ Havells/ as per direction of EIC) as to GS. 6A - 32A SP MCB
63A TP MCB
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Make- R R Kabel/ Havells/ KEI/ Polycab/ as per direction of EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch (Brand approved by EIC) fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar with holes fixed on bakelite/hard rubber insulation over the welded chairs incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65 inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] Average run 9 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FRLS ' PVC insulated & unsheathed copper wire (Make- R R Kabel/ Havells/ KEI/ Polycab/ as per direction of EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FRLS' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box andmending good the damages to original finish On Board
Supply & Fixing 240 V, 2 x 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 200 x 150 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 20A, plug socket with separate 20 APiano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150 x 100 x 65mm MS (16SWG) switch board and bakelite /perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A plug socket with separate 2 nos. 6 A & 2 nos. 20A Piano key type switch, indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x 20 0x 65mm MS (16SWG) switch board and bakelite / perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x 200 x 65 mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required ( Computer / Medical Instrument Board )
Supply and Drawing 1.1 KV single core stranded 'FRLS' PVC insulated & unsheathed copper wire (Make- R R Kabel/ Havells/ KEI/ Polycab/ as per direction of EIC) of following sizes in thick heavy gauge polythene pipe and necy. connection as required incl. cutting channel of (40mmx40mm)/ (43mmx43mm)size on masonary wall by electric operated cutting machine with S&F heavy gauge 19mm/25mm dia 3mm thick polythene pipe by means of iron hooks and mending good damages to building works 2 x 1.5 sqmm + 1 x 1.5sqmm (for Separate Plug) (19mm dia 3 mm thick)
2 x 2.5 sqmm + 1 x 1.5sqmm (for Power plug ) (19mm dia 3 mm thick)
2 x 4 sqmm + 1 x 2.5sqmm (for AC ) (25mm dia 3 mm thick)
2 x 6 sqmm + 1 x 4 sqmm ( from TPN MCB DB to SPN MCB DB s ) (25mm dia 3 mm thick)
4 x 6 sqmm + 2 x 4 sqmm ( for Auto Clave M/C ) (25mm dia 3 mm thick)
Supplying of following sizes Al. armoured PVC/XLPE (Make- R R Kabel/ Havells/ Glostar / as per direction of EIC) 4 core 10 sqmm (For Security Light)
4 core 35sqmm ( from VTPN to MCBPBDB )
4 core 70 sqmm ( from Panel to VTPN & Panel to DG & DG to VTPN )
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc.
Laying of one No. cable of following sizes in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed Upto 35 sq mm
above 35 sq mm upto 185 Sqmm
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 10 sqmm
4 core 35 sqmm
4 core 70 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials 4 core 10 sqmm
4 core 35 sqmm
4 core 70 sqmm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 50 mm dia
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector,6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. With 25x25x3mm angle iron support 200x50x1.25mm (18SWG).
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire Up to 50sqmm
Supply & Delivery of AC 240V 50 Hz 48" sweep (1200 mm) ceiling fan complete with down rod , Canopy, fork incld. safety wire of suitable gauge with out regulator, (Make- Usha Striker plus with safety wire & P2 capacitor/ equivalent model of Crompton Greaves / Orient/ as per direction of EIC).
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting.
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/ perspex top cover by after making housing for regulator by cutting bakelite top cover incl. making necy. connections etc. as per G.S.
S & D 250 V 50 HZ 18" (450 mm) high flo oscillating type metal body Wall Bracket fan operated by pull cord switch with inbuilt regulator (Make- Orient Tornedo 2/ equivalent model of CG/ Usha/ as per direction of EIC)
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S 1.5 sq mm
S&F angular holder (Anchor) on 3" wooden double round block incl. S&F 9 Watt LED lamp (Make- Philips/ CG/ Wipro/ Jaquar/ as per direction of EIC).
Supplying & Delivery 4 feet single commercial LED type fluorescent light fittings complete with all accessories with 1 x 18 Wt.Master LED Tube lamp [ Make -Philips Model No- TMC 502 1xT-LED 22W with 18 W master tube Mas LED Tube 1200mm 18W865 T8 I/ equivalent model of CG/Wipro/ Jaquar/as per direction of EIC)
Supplying & Delivery 4 feet twin commercial LED type fluorescent light fittings complete with all accessories with 2 x 18 Wt.Master LED Tube lamp [ Make -Philips Model No- TMC 502 2xT-LED 22W with 2 nos 18W master tube Mas LED Tube 1200mm 18W865 T8 I/ equivalent model of CG/Wipro/ Jaquar/as per direction of EIC)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm ) flexible copper wire of 1.10 mt. length.
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
Supplying & Fixing 250 V Bulk Head Outdoor Light Fittings (Make- Crompton LBHE-10-CDL/equivalent model of Philips/Wipro/ Jaquar/as per direction of EIC) by Screws on wall/ceiling etc.
S & D of 220V 120 W LED Flood Light as per direction of EIC. Make: Crompton TFS 504-100-57-NL-SL-GL-NSG/ equivalent model of Phillips/Wipro/ Jaquar/as per direction of EIC)
Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required
Supply & Delivery 240 V,50 Hz, Metal body Heavy duty Exhaust fan of following sizes and RPM (Make -- EPC/ equivalent model of CG/ Usha/ Orient/ as per direction of EIC) 12" (30 cm), 920 RPM
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following dia incld. Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 12" (30 cm), 920 RPM
Engraving the deptt. No. for ceiling/exhaust fan upto 10 letters incl. hifen,stroke or stop as to GS
Painting upto 10 letters of the engraved No. with approved black paint/red paint as required as to GS
Extra for additional one letter incl. hifen,stroke or stop as to GS
Extra painting for additional one letter of the engraved No. with hifen,stroke etc. with black paint/red paint as required as to GS
S/F OLP - 30A A.C Starter suitable with G.I box flushed in wall with voltage check, Amp check, Time check incl. all connection. (Brand approved by EIC)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Make- Legrand/ Havells/ L&T/ Gold Medal/ as per direction of EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc as per G.S.
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
Supply & Delivery of 1.5/1.6 TR Hi-Wall Split Air Conditioner having following specification:- 1) Cooling capacity Nominal (BTU/HR): 20301 2) Minimum ISEER rating- 3.5, IS compliance - IS 1391 3) Refrigerant- R410A/R32 4) Compressor- Rotary/Scroll 5) Evaporator & Condensor Coil : Copper 6) Operating Outdoor Temparature = 50°C and above 7) Power Supply- 230 V, 50 HZ (Tolerance as per applicable standard) 8) Min Room Discharge Air Flow Rate- 1300 CMH 9) Cordless Remote Arrangement with all modernized provision of temperature setting, Fan speed option (Low/Medium/High) Auto Swing. (Make- Mitsubishi Electric/ Mitsubishi Heavy/ O-General/ Daikin/ as per direction of EIC )
Installation, Testing & commissioning of 1.5/2.0 Tr. Split type AC both indoor/ outdoor unit incl. S& F of 40 X 40 X 5 mm MS angle iron frame for installation of ODU and sealing of the holes in wall created during the copper pipe connection between IDU & ODU by proper sand-- cement plastering and painting (both inside and outside) to match up with the original finish mending good the damages to complete the instn as per direction of EIC.
S& F laying of - (i) gauge copper pipe 5/8" 0.7 mm thick for suction (ii) copper pipe 1/4" 0.6 mm thick for discharge (OEM make) with 9 mm thick thermal insulation foam both for suction & discharge pipe and mending good the holes & damages as directed by EIC. (extra length for distance of ODU & IDU exceed 3 mtr.)
S& Laying 4 core 2.5 sqmm PVC insulated & unarmoured copper cable (Make- R R Kabel/ Havells/ Glostar / as per direction of EIC) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.)
S & F of flexible PVC/ HDPE high quality water carrying pipe of 32mm size for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC.
S&F Auto clave starter unit of size 16" x 12" x 6" made from heavy gauge CRC sheet metal (16 SWG) with 1 no. Front openable hinged type door fixed in wall on flate iron frame. The interconnection should be made by suitable sizes cu wire. The box should be painted by power coated paint & having following accessories:- a) 4 pole power contactor ML3 40 LT make -1 no. b) Add on aux. contact block 2 no. + 2nc (LT make ) - 1 no. c) 40 A 4 pole MCB Isolator (Legrand)- 1no d) push bottom switch - 2 nos. e) LED indigator lamp (ESBEE)-3nos. f) 200 A capacity 4 way terminal - 1 no
Supply & Delivery of 100 W LED outdoor street light fitting (Make- Crompton LSTP-100-CDL-M/ equivalent model of Philips / Wipro/ Jaquar/ as per direction of EIC)
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex/ Legrand/ as per direction of EIC) of size 8"X10" comprising of 4 way 100 Amp. Capacity brass stud/terminal make- AC /DC.,having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement,comprising of one 250V,15A kit-kat fuse unit,one NL on porcelain insulator etc. conceal in wall as per direction of EIC
Inter connection between loop box to fittings by 1.1KV 3X 1.5sqmm single core strandred 'FRLS' PVC insulated & unsheathed copper wire (Make- R R Kabel/ Havells/ KEI/ Polycab/ as per direction of EIC) laying through PVC rigit Conduit (Make: Precision) incld.neccy. fittings as per direction of EIC.
Providing CC (6:3:1) muffing 600x600x760 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if necessary(without loop box)
Supplying and fixing Timer panel M S Box with hing type front open door and threathed locking arrangement in one side made of 18 SWG CRCA MS Sheet of size 500x300x200 mm. fixed in wallon flate iron frame as per direction EIC.The Box shuld comprising following accessorise. A) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer similar to ( Microrex QT31 ) of quartz driven running reserve Day dial back up by nickle cadmium battery (Make - GEC / Legrand/ as per direction of EIC ) – 1 no B) One no. ML-3 conctractor,(L&T make) with ( 2 NO or 1 NO + 1 NC Aux. Contract ) ( Make - Legrand / L & T/ as per direction of EIC ) – 1 no C) 4 pole 32 Amps MCB ( L & T / Ligrand/ as per direction of EIC ) - 1 no D) Auto / Manual By pass Toggle Switch arrangement – 1 no. E) 250 V , Diode type neon Indicator lamp ( Make - Legrand / L & T/ as per direction of EIC ) – 1 no F) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar , with spring washer ,nuts etc with this box for termination of power to complete arrangement must be wiring by 4 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (for controlling outdoor street light fitting fittings) (Make - Legrand /L & T / as per direction of EIC)
Main LT Panel ( Normal Supply ) Supply & delivery of cubical type L.T. Distribution panel board of required size wall cum floor mounted compartmentalized with maple arrangement having rigid & self supporting structure fabricated from 2 mm thick CRCA sheet steel with M/S angle frame. The panel board consisting of the following switches & the Panel board to be get inspected by EIC -- A) Incoming Arrangement. a) switch disconnect or fuse (panel mounting cubical type) conform to IS : 13947 in open execution three pole & Neutral AC 23A, 50HZ, 415 Volt 400 Amp with 3 nos 400Amp DIN type HBC fuse link , L&T / SIEMENS make . . --1 No B)Bus Section: 415 V 800 A. electrolyte grade tinned copper bus bar with vertical section of required size same in size for Phase RYB, & neutral bars & 20x 5 mm Al. Bar for earth. A bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C C) Outgoing arrangement: a) switch disconnect or fuse (panel mounting cubical type) conform to IS : 13947 in open execution three pole & Neutral AC 23A, 50HZ, 415 Volt 125 Amp with 3 nos 125 Amp DIN type HBC fuse link , (Make- L&T / ABB/ HAVELLS/ SIEMENS/ AS PER DIRECTION OF EIC) . . --2 Nos. b) Switch disconnector fuse (panel mounting cubical type) conform to IS: 13947 in open execution three pole & Neutral AC 23A, 50HZ, 415 Volt 100 Amp with 3 nos 100 Amp DIN type HBC fuse link, (Make- L&T / ABB/ HAVELLS/ SIEMENS/ AS PER DIRECTION OF EIC) . ---- 2 Nos. c) Switch disconnector fuse (panel mounting cubical type) conform to IS: 13947 in open execution three pole & Neutral AC 23A, 50HZ, 415 Volt 63 Amp with 3 nos 63 Amp DIN type HBC fuse link, (Make- L&T / ABB/ HAVELLS/ SIEMENS/ AS PER DIRECTION OF EIC) --- 2 Nos.
Earthing. A separate earth bolts/Bars – 2 Nos will be provided in panel board in both sides as per drawing. Cable Alley: Cable entry arrangement will be provided in the cubical panel in vertical position of size with reqd sizes of AC/DC make connector indicating phase & neutral for each outgoing main switches & gland plate must be placed at the bottom of the panel with detachable type as per direction of E.I.C. Painting. The complete panel board shall be painted by 2 coats of powder coated synthetic enamel Paint over two coats of R.O. primer of Approved make & brand & color as per Direction of E.I.C. Constructural Details: All incoming & outgoing panel mounted cubical Switch disconnector fuse shall be housed in Respective compartment with hinged & gasketted Door at front. All doors shall have Panel lock Arrangement. The panel shall be properly Gasketted to prevent ingress of dust & moisture & Remaining . Busbar will be properly arrange & all Switches shall be fixed by M.S. nuts & bolts On angle /flat iron frame base.as per direction of E.I.C. Installation : The panel should be installed as per site condition & requirement with brick pedistal / foundation etc to comp the installation as per Direction of E.I.C. .
Supplying and fixing 415V, TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc incl S&F cable end box (Make- L&T / ABB/ HAVELLS/ SIEMENS/ AS PER DIRECTION OF EIC) 100 Amp
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T / ABB/ HAVELLS/ SIEMENS/ AS PER DIRECTION OF EIC) 63A
SITC of 30 KVA Silent Diesel Generator Set (Make- JAKSON/ MAHINDRA/Ashok leyland/as per direction of EIC) with microprocessor based genset controller suitable for solo application & alternator both mounted on a common base plate with fuel tank, residential silencer, AVM Pads with its leads, first fill of lube oil & Acoustic Enclosure (dimension as per standerd) subject to observation of Pollution Norms (CPCB-II approved) and confirming to latest BIS code with capacity of 10% over loading for one hour in twelve hours duration having following main items and accessories : A. DIESEL ENGINE (Make- CUMMINS/ MAHINDRA/ASHOK LEYLAND/as per direction of EIC) : Diesel Engine developing 80 BHP (max) at 1500 RPM water cooled, four stock, Electric start, 3 Cylinder, Turbo Charged & after cooled model, confirming to BS 5514 with the following accessories : a. Air intake system -- Air intake manifold, Dry type Air cleaner, and Vacuum indicator. b. Exhaust System -- Turbocharger, Flexible connection, Exhaust manifold, Exhaust Silencer Residential type. c. Coolant System -- Engine Water pump, radiator, coolant additive concentrate, by pass thermostat. d. Lubricating System -- Oil pan, Engine mounted lube oil pump, Full flow lube oil filter, Lub oil by pass filter. e. Fuel System -- PT Fuel Pump with electronic Governor, ESTC injector, 24V DC Solenoid Coil, Replaceable fuel filter. f. Starting System -- 12V DC Electric Starter, 12 V DC battery charging Alternator. g. Safety Controls -- Low lube oil pressure trip, High water temperature trip, Over speed Stop.
Integrated Control System (As per direction of EIC): a. Physical Construction -- LCD alpha-numeric display with 8 membrane key inter face, Non metallic enclosure, LED Display - fault warning and generator set status, Key switch for OFF / RUN / START. b. Governor & Speed / Frequency regulator -- Integrated electronic Governing (adjustable up to 5%). c. Operator Interface -- Manual Stop/Start, Remote Start/Stop Cyclic cranking, Alpha numeric screen, Alternator trim adjustment. d. AC Instruments -- 3-Ph AC Ammeter, 3-Ph AC Voltmeter, KW meter, KVA meter, PF meter, Frequency meter. e. Measurements / Instrumentation -- Lube oil pressure, Coolant Temperature, Engine speed, Hours run, Battery voltage. f. Engine Protection -- High coolant temperature (warning& shutdown), Low lube oil pressure (warning& shutdown), Fail to crank (Shutdown), Over speed (Shutdown), Low / High battery Voltage (Warning), Low Coolant level shutdown. g. AC Protection -- Over Frequency (shutdown), Under Frequency (warning), Over Voltage (Shut down), Over Current (Shut down), Under Voltage (warning). h. Other Accessories -- Operating temperature range 0-60°C, common fault alarm, common shutdown, Date and time stamp for alarm. i. Additional features – Speed bias or raise / lower inputs are provided for paralleling, Remote monitoring capability through separate interface modules, Engineering tool / manufacturing tool compatible with existing tools, 6 configurable discrete Outputs, 2 configurable discrete Inputs, Fault Indication on front panel display using fault LEDs, Smooth transition to rated speed, Programmable fault threshold, Controlled ramping to restricted startup smoke. j. Others -- Vibration damper, Fly wheel with housing.
B. ALTERNATOR (Make: STAMFORD / Greaves Power/ LEROY SOMER/ LEYPOWER/as per direction of EIC): Synchronous Alternator 30 KVA rating, suitable for continuous operation at 1500 RPM, 415Volts, 0.8 P.F (lag), 50 Hz., 3 Ph, 4 Wire system. The Alternator shall be Brushless type, self excited & self regulated through an AVR. The Alternator will be suitable for tropical climate and shall generally Confirm BS 2613/ IS : 4722. The Salient feature of Alternator are : -- a. ± 0.5% Voltage regulation (Max.) in static condition. b. IP : 23 protection with class “H” insulation. c. Permanent lubricating bearing. d. Permissible over load of 10% for one hour in 12 hours of operation. C. AMF CONTROL PANEL (Make: C & S / JAKSON /MAHINDRA/ASHOK LEYLAND/ as per direction of EIC): Inbult AMF Panel including display of all parameter & safety indication D. BASE FRAME (as per direction of EIC) : Engine and Alternator are mounted through AVM pads, on a common Channel iron fabricated Base Frame with pre-drilled holes. E. FUEL TANK (as per direction of EIC): Daily service INBUILT fuel tank of suitable capacity fabricated for 14 SWG CRCA sheet metal completed with drain valve, air vent, inlet out let connection. The fuel tank shall be floor mounted type placed outside the acoustic enclosure. F. BATTERIES (Make: Exide/ Amaron/ As per direction of EIC): 12V, 160 AH suitable make batteries in dry and uncharged condition with it leads. G. ACOUSTIC ENCLOSURE (as per direction of EIC): 1 No. (CPCB II APPROVED) Should have optimum service ability, Air inlet louvers, Powder coated made of stainless steel.
Salient Feature of Acoustic Enclosure (30 KVA) : The Acoustic enclosure is made of 14 / 16 SWG CRCA sheet. The Salient feature of the acoustic enclosure are : - a. The enclosure is of modular construction with the provision to assemble and dismantle easily at site. b. The Sheet metal component are NINE TANK pre treated before powder coating. c. The enclosure is powder coated (inside as well as outside) with special pure polyester base powder. All nut and bolts /external hardware are made from stainless steel. d. The doors are gasketed with high quality EPDM gaskets to prevent leakage of sound. e. The door handle are lockable type. f. The sound proof of the enclosure is done with quality Rock wool / Mineral wool confirming IS : 8183. The rock wool is further covered with fiber glass tissue and perforated sheet. g. Special design attenuators are provided to control sound at air entry and exit points. h. Temperature of enclosure does not exceed beyond 7 - 10°C of ambient temperature. i. There is a provision of emergency shut down from out side the enclosure. j. Noise level is <75 dB (A) at 1 mtr. distance under free field condition, i.e. as per CPCB norms. k. Door hinges are made of anti corrosive special alloy.
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 25 mm dia x 150 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts as per GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as to GS.
Connecting the equipments to earth busbar including S & F No. 7/14 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as to GS.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.
Extra for treatment of soil by using salt & charcoal or coke for plate electrode as to GS.
a) Dismantling all types of plain cement concrete works, stacking serviceable materials at site & removing rubbish as directed by EIC within a lead of 75 Mtr. (upto 150 mm thick)
b) Ordinary cement concrete (mix. 1:2:4) with graded stone chips (20 mm size) excluding shuttering & reinforcement, if any, in ground floor as per relevant IS code (Pakur variety)
c) 125 mm thick brick work with 1st class bricks in cement morter (1:4) in ground floor.
d) Plastering of surface upto 20 mm thick by cement morter (1:4) in ground floor.
e) Neat cement punning about 1.5 mm thick in wall - do - - do - window, sillis, floor, drain etc.
Supply & erection of self supproting special type MS structure made from 50 mm dia Hollow Pipe, 50 x 50 x 8 mm & 40 x 40 x 6 mm MS Angle incl. S&F of Anodised GI Sheet for cover up the DG Set after construction of CC Base for 50 KVA DG Set as per direction of EIC. (drawing & details of structure to be submitted & approved by EIC before taking up the work)
Excavation of soil for installation of Earth Electrode and filling & ramming as to GS. For morrum soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed (:For Morrum Soil ISI-Medium GI pipe as to GS.
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as to GS.
Connecting the equipments to earth busbar including S & F No. 10 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages as to GS.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe as to GS.
i) Supply and fixing of angle iron frame fabricated from 40 mm x 40 mm square four nos hollow bar with cross and radial support including one no 40x40 mm angle iron support in the middle for the Sign board of following size with suitable three nos. crosss angle support welded with 4 nos angle hook in equal space for fixing on the structure with all necessary welding and fabrication. The structure shall rest in both sides with proper welding as per instruction of EIC. ii) S&F LED Sign Board made 3 mm thick ACP Sheet (Alstrong/ Aludecor) finished with approved metallic colour as back ground (blue) after router cutting. The riser structure also shall be covered with ACP Sheet.& appx 6-7 inch depth (Both size ACP sheet) iii) S&F Special type of imported acrylic English letter appx 50 mm thickness flushed on the ACP board made on imported acrylic ACAST sheet. The following letter font shall be in horizontal line as mentioned. iv) S&F SMD LED inside the board and to run for each letter including wiring , soldering etc and fixing the SMPS properly with the specification of the SMD --- 1. LED colour : White/ Red/ Blue (make-samsung /Nichia /Cree/Hisine ) 2.Stright : 2 or 3 nos LED per module 3. Luminous Flux : 140 LUMEN 4. Life : 70000 burning hours 5. Visibility: 100 meter atleast normal eye 6. Power Supply: 1.2 watt to1.6 watt per module 7.Input : 230A.C , Output : 12V DC 8.Shape of LED : recrangle or square 9. Grade : IP - 65
v) S & F LED Power supply 300/ 400W IP65 50/60Hz frequency, 108 to 305 VAC driver power supply other electrical accessories the panel prepared along with its necessary arrangement ( make Hisine/Migion/Cehosa/PWD appvd ) vi) Cost of painting of MS structure with 2 coats of RO primer and one coat of synthetic enamel paint after scrapping with emery paper properly make ICI/Asian paints vii) Cost of erection of scaffolding for fixing the Signage v) S & F LED Power supply 300/ 400W IP65 50/60Hz frequency, 108 to 305 VAC driver power supply other electrical accessories the panel prepared along with its necessary arrangement ( make Hisine/Migion/Cehosa/PWD appvd ) vii) Cost of erection of scaffolding for fixing the Signage viii) Testing and commissioning of the LED board as per following nomenclature ix) cost of carrying the LED sign board from work shop to site
RIK ENTERPRISE
RS SYSTEMS AND PROJECTS
DURGAPUR POWER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .