Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.7 L+₹98,150 (3.82%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹27.5 L+₹1.8 L (6.94%)Rejected-Finance S 5 POST OFFICE BUILDING BATWARA SRINAGAR | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹27.9 L+₹2.2 L (8.64%)Rejected-Finance DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹28.1 L+₹2.4 L (9.15%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹57,700
Closing Date
25 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS PIN-914133 C/O 56 APO
PROVN OF 01X100 KVA GEN SET FOR SECURITY LIGHT IN SECT D AND 02X62.5 KVA GEN SET FOR SECURITY LIGHT IN SECT E OF BB CANTT SRINAGAR
2021_MES_438720_1
CWEK-11/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 864 EWS
Class D Category b i
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹57,700
Yes
HQ 133 WORKS ENGRS
24 Aug 2021
27 Apr 2021
27 May 2021
27 Apr 2021
25 May 2021
11 May 2021
27 Apr 2021 - 4 May 2021
6 May 2021
60 days
Amount
Supply, Installation, testing and commissioning of silent type Diesel engine driven generating set with Governing class (as per ISO 8528 Part V) -G2 incl sound reducing canopy (sound level not more than 75 db) 14 guage as per guideline issued by Ministry of Environment & forest notification, & Central pollution control board or GSR 54(E) dt 23 Jan 2015, 415 volts, 3 phase, 50 Hz supply complete with panel for automatic starting or main failure control panel suitable for giving an output of 100 KVA (80 KW) after considering derating factor confirming to IS-1601 at 1800 Mtr altitude above mean sea level and capable of operating between temperature range (-20) degree C to 35 degree C (at Srinagar area of J & K) and alternator of suitable capacity and RPM coupled with each other & capable of taking 10% over load for one hours on every 12 hours (As per BS-5514/649) with flexible coupling mounted on common base plate on Antivibration pads on foundationas recommended by manufacture. The DG set shall comprise of Electric starter motor with batteries, Turbocharger, water cooled & comprising all standard fittings, fixtures & all piping etc as below :- (a) Alternator : Directly coupled with Engine and suitable to produce 415 volts, 3 phase 4 wire system, 50 Hz 0.8 PF @1500 RPM of capacity 100 kVA all as per as per IS: 13364 and up to date amendments with H class insulation having efficiency 91% on 100% load at 0.8 PF, self excited, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole faces as per IS-4722 or BS 2613-1970 all as specified and directed
(b) Engine : Water cooled Deisel Engine (CPCB Norms Compliance) developing Min 115 BHP or as recommended by the manufacturer having Self start engine (including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS:10001/ 10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with AI electronic governer suitable to regulate speed of DG set from No load to full load completed with fuel tank of cap as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters cold start kit etc all as specified and directed. (c)Canopy : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Critical processes of punching is done on CNC machines to maintain dimensional accuracy of holes within 0.1 mm. Powder coating is done after seven‐tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE‐RETARDANT foam as acoustic material . Four hinged doors shall be provided to canopy, one door shall have glass window for control panel.
(d) Base Frame : Base frame is fabricated in sheet metal. The base frame will be primer coated and painted. The base frame is rugged n construction and designed for mounting engine and alternator close coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure & control panel on in it. The base frame is having provision of lifting hook for convenient lifting of complete set, i.e. along with canopy, engine and alternator. (e) Generating Panel :- DG set should consist of standard Generating Panel. (f) Exhaust System: The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant / non igniting foam conforming to BIS 7888/BS 4375 to prevent excess heat radiation on the engine and safe for operator. (g) Fuel Tank: Fuel tank shall be fabricated out of 16 SWG CRCA MS Sheet . It is duly painted and fitted with inlet and outlet connections. Float gauge and fuel float switch is provided. Fuel tank shall have guage duly calibrated at every 5 mtrs. daily service fuel tank of suitable capacity as per manufacturer's instruction of having min fuel storing cap of 12 hours for running DG set including fuel oil indicating gauge drain and vent plug etc complete on a common base within the acoustic enclosure.
(h) Control Panel :- Alternator inbuilt control panel 415 Volt ,3 phase, 4 wire, 50 cycle fabricated out of 1.6mm thick MS sheet painted with internally/externally with two coats of synthic enamelled paing over one coat of primer complete with internal copper wiring sutiable for 62.5 KVA DG Set comprising of MCCB 4P,100 Amp 25KA 01 No with spreader link,Multifunctional meter suitable to indicate Volt,power factor,bty voltage,RPM frequency,temp, oil pressure,hours run,Current AMP,KW, KWH etc. Note:-1. Place of installation- Near BB Cantt Srinagar. 2. PCC platform 1:2:4 600 mm thick using 40mm graded stone aggregate to suit base frame size 45 cms below & 15 cms above ground level. Grouting 08 bolts of 600mm x 30mm and fixing the engine and alternator with base frame on the platform. PCC shall be measured & paid separately. 3. Engine and alternator shall be assembled on common steel frame by the manufacturer itself and not by rep / authorised agent / sister concern etc. 4. Engine shall be designed keeping in consideration of de-rating factor for 1800 meters altitute. 5. Canopy and engine shall be of same make. 6. Installation, testing and commissioning of Gen Set shall be done in presence of maufacturer's Engineer and not by any authorised person / rep/sister concern etc 7. DG Set to be tested for 12 Hrs contineously on full load (Rated load) including 1 Hr at 110% load. All testing materials and fuel to be provided by the contractor. 8.complete unit/set shall be equipped with all standard fitting as per manufacture recommendations and mounted on common base frame with following fitting and rates shall be deemed to be inclusive of the same:- (a) Fly wheel with bousing (b) Cooling system : Mounted radioter with fan and belt (c) Cooling water pump : Centrifucal type belt driven (d) Exhaust gas (i) turbo charger type (ii) Exhaust mainfold, Silencer : (i) Residential type,(ii) Bellows (d) Fuel System: Fuel injection system with fuel injectors fuel injection solenoid switch/nozzle/governer electronic type capable for 1% speed/frequency reglation.fuel filters,fuel hoses(e)Lub oil System:(i) Lubricating oil filter (ii) Lubricating pump (f) Air intake System :
8.complete unit/set shall be equipped with all standard fitting as per manufacture recommendations and mounted on common base frame with following fitting and rates shall be deemed to be inclusive of the same:- (a) Fly wheel with bousing (b) Cooling system : Mounted radioter with fan and belt (c) Cooling water pump : Centrifucal type belt driven (d) Exhaust gas (i) turbo charger type (ii) Exhaust mainfold, Silencer : (i) Residential type,(ii) Bellows (d) Fuel System: Fuel injection system with fuel injectors fuel injection solenoid switch/nozzle/governer electronic type capable for 1% speed/frequency reglation.fuel filters,fuel hoses(e)Lub oil System:(i) Lubricating oil filter (ii) Lubricating pump (f) Air intake System (i) Air intake Manifold (ii) Air cleaner dry type (g) Governer : Electronic Governer with actuator (h) Starting System : Electric Self starter with maintenance free batteries including battery charging alternator (j) Batteries : maintenenace free batteries of 12 Volt /24 volt as per manufacturer direction complete with copper conductor multistranded lead of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electronic all as specified. Starter gear ring, start and stop push button , ignition key/switch,(k) Handing and operation : Sailent features of accessories shall be as under :-Radiator with blower fan , Corrosion inhibitor coolent, paper element filter for fuel, lub oil and by pass, Elecronic governer controlled direct fuel injection system, Fly wheel housing and fly wheel (k) Generator Monitoring Panel : Comprising of following:- (i) Microprocessor based genset controller for metering, monitoring,governing and protection (ii) Engine protection for low oil pressure, high coolent temperature (alarm & shutdown) (iii) Alternator protection parameter like under voltage, over current, under frequency, over frequency, (alarm & shutdown) (iv) Relay drivers for remote annuciations (v) Cyclic cranking (vi) Auto/manual strat/stop (vii) Operator within a temperatur ( range (-20 to 60 degree C) and humidity upto 95% (viii) Remote monitoring capacity throught separate interface moudules (m) Genset metering parameters like lube oil pressure, coolent temperature, engine speed (RPM), run hours, DC voltage, intake manifold temperature, 3 phase volts and 3 phase amperes,frequency, KW,KVA, power factor. (n) Safety Controls :- Engine low lube oil pressure, high water temparature and over speeding of engine (o) Coupling arrangement : Flexible coupling, fly wheel to suit flexible coupling fly wheel housing (p) Accessories :- AVM pads builts or separately mounted to manufacture base frames.(q) Base frame : Stardy design made of MS channel with necessary reniforcement and predetermined holes. (r) daily service fuel tank of suitable capacity as per manufacturer's instruction of having min fuel storing cap of 12 hours for running DG set including fuel oil indicating gauge drain and vent plug etc complete on a common base within the acoustic enclosure.
(k) Generator Monitoring Panel : Comprising of following:- (i) Microprocessor based genset controller for metering, monitoring,governing and protection (ii) Engine protection for low oil pressure, high coolent temperature (alarm & shutdown) (iii) Alternator protection parameter like under voltage, over current, under frequency, over frequency, (alarm & shutdown) (iv) Relay drivers for remote annuciations (v) Cyclic cranking (vi) Auto/manual strat/stop (vii) Operator within a temperatur ( range (-20 to 60 degree C) and humidity upto 95% (viii) Remote monitoring capacity throught separate interface moudules (m) Genset metering parameters like lube oil pressure, coolent temperature, engine speed (RPM), run hours, DC voltage, intake manifold temperature, 3 phase volts and 3 phase amperes,frequency, KW,KVA, power factor. (n) Safety Controls :- Engine low lube oil pressure, high water temparature and over speeding of engine (o) Coupling arrangement : Flexible coupling, fly wheel to suit flexible coupling fly wheel housing (p) Accessories :- AVM pads builts or separately mounted to manufacture base frames.(q) Base frame : Stardy design made of MS channel with necessary reniforcement and predetermined holes. (r) daily service fuel tank of suitable capacity as per manufacturer's instruction of having min fuel storing cap of 12 hours for running DG set including fuel oil indicating gauge drain and vent plug etc complete on a common base within the acoustic enclosure.
Supply, Installation, testing and commissioning of silent type Diesel engine driven generating set with Governing class (as per ISO 8528 Part V) -G2 incl sound reducing canopy (sound level not more than 75 db) 14 guage as per guideline issued by Ministry of Environment & forest notification, & Central pollution control board or GSR 54(E) dt 23 Jan 2015, 415 volts, 3 phase, 50 Hz supply complete with panel for automatic starting or main failure control panel suitable for giving an output of 62.5 KVA (61KW) after considering derating factor confirming to IS-1601 at 1800 Mtr altitude above mean sea level and capable of operating between temperature range (-20) degree C to 35 degree C (at Srinagar area of J & K) and alternator of suitable capacity and RPM coupled with each other & capable of taking 10% over load for one hours on every 12 hours (As per BS-5514/649) with flexible coupling mounted on common base plate on Antivibration pads on foundationas recommended by manufacture. The DG set shall comprise of Electric starter motor with batteries, Turbocharger, water cooled & comprising all standard fittings, fixtures & all piping etc as below :- (a) Alternator : Directly coupled with Engine and suitable to produce 415 volts, 3 phase 4 wire system, 50 Hz 0.8 PF @1500 RPM of capacity 62.5 kVA all as per as per IS: 13364 and up to date amendments with H class insulation having efficiency 91% on 100% load at 0.8 PF, self excited, self regulated, screen protected drip proof type with two end shield ball/Roller bearing with damper winding in each pole faces as per IS-4722 or BS 2613-1970 all as specified and directed (b) Engine : Water cooled Deisel Engine (CPCB Norms Compliance) developing Min 61 kW / 83 BHP or as recommended by the manufacturer having Self start engine (including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS:10001/ 10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with AI electronic governer suitable to regulate speed of DG set from No load to full load completed with fuel tank of cap as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters cold start kit etc all as specified and directed.
b) Engine : Water cooled Deisel Engine (CPCB Norms Compliance) developing Min 61 kW / 83 BHP or as recommended by the manufacturer having Self start engine (including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator complete with foundation (foundation design as per OEM), as per IS:10001/ 10002, coupled directly through flexible coupling, multi cylinder four stroke, cold starting, 1500 RPM industrial type as per BS-649 or IS-1601 with AI electronic governer suitable to regulate speed of DG set from No load to full load completed with fuel tank of cap as per manufacturer recommendations, fuel lines, exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continuous operation and standard accessories, sump pre heaters cold start kit etc all as specified and directed. (c)Canopy : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS sheet. The silent canopy shall be of nut bolt type construction. Critical processes of punching is done on CNC machines to maintain dimensional accuracy of holes within 0.1 mm. Powder coating is done after seven‐tank surface preparation process of sheet metal. Canopy panel and doors shall have inside lining of FIRE‐RETARDANT foam as acoustic material . Four hinged doors shall be provided to canopy, one door shall have glass window for control panel.
(d) Base Frame : Base frame is fabricated in sheet metal. The base frame will be primer coated and painted. The base frame is rugged n construction and designed for mounting engine and alternator close coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure & control panel on in it. The base frame is having provision of lifting hook for convenient lifting of complete set, i.e. along with canopy, engine and alternator. (e) Generating Panel :- DG set should consist of standard Generating Panel. (f) Exhaust System: The exhaust system and noise suppressor shall be provided with thermal insulation by using fire retardant / non igniting foam conforming to BIS 7888/BS 4375 to prevent excess heat radiation on the engine and safe for operator. (g) Fuel Tank: Fuel tank shall be fabricated out of 16 SWG CRCA MS Sheet . It is duly painted and fitted with inlet and outlet connections. Float gauge and fuel float switch is provided. Fuel tank shall have guage duly calibrated at every 5 mtrs. daily service fuel tank of suitable capacity as per manufacturer's instruction of having min fuel storing cap of 12 hours for running DG set including fuel oil indicating gauge drain and vent plug etc complete on a common base within the acoustic enclosure. (g) Control Panel :- Alternator inbuilt control panel 415 Volt ,3 phase, 4 wire, 50 cycle fabricated out of 1.6mm thick MS sheet painted with internally/externally with two coats of synthic enamelled paing over one coat of primer complete with internal copper wiring sutiable for 62.5 KVA DG Set comprising of MCCB 4P,100 Amp 25KA 01 No with spreader link,Multifunctional meter suitable to indicate Volt,power factor,bty voltage,RPM frequency,temp, oil pressure,hours run,Current AMP,KW, KWH etc.
(h) Control Panel :- Alternator inbuilt control panel 415 Volt ,3 phase, 4 wire, 50 cycle fabricated out of 1.6mm thick MS sheet painted with internally/externally with two coats of synthic enamelled paing over one coat of primer complete with internal copper wiring sutiable for 62.5 KVA DG Set comprising of MCCB 4P,100 Amp 25KA 01 No with spreader link,Multifunctional meter suitable to indicate Volt,power factor,bty voltage,RPM frequency,temp, oil pressure,hours run,Current AMP,KW, KWH etc. Note:-1. Place of installation- Near BB Cantt Srinagar. 2. PCC platform 1:2:4 600 mm thick using 40mm graded stone aggregate to suit base frame size 45 cms below & 15 cms above ground level. Grouting 08 bolts of 600mm x 30mm and fixing the engine and alternator with base frame on the platform. PCC shall be measured & paid separately. 3. Engine and alternator shall be assembled on common steel frame by the manufacturer itself and not by rep / authorised agent / sister concern etc. 4. Engine shall be designed keeping in consideration of de-rating factor for 1800 meters altitute. 5. Canopy and engine shall be of same make. 6. Installation, testing and commissioning of Gen Set shall be done in presence of maufacturer's Engineer and not by any authorised person / rep/sister concern etc 7. DG Set to be tested for 12 Hrs contineously on full load (Rated load) including 1 Hr at 110% load. All testing materials and fuel to be provided by the contractor. 8.complete unit/set shall be equipped with all standard fitting as per manufacture recommendations and mounted on common base frame with following fitting and rates shall be deemed to be inclusive of the same:- (a) Fly wheel with bousing (b) Cooling system : Mounted radioter with fan and belt (c) Cooling water pump : Centrifucal type belt driven (d) Exhaust gas (i) turbo charger type (ii) Exhaust mainfold, Silencer : (i) Residential type,(ii) Bellows (d) Fuel System: Fuel injection system with fuel injectors fuel injection solenoid switch/nozzle/governer electronic type capable for 1% speed/frequency reglation.fuel filters,fuel hoses(e)Lub oil System:(i) Lubricating oil filter (ii) Lubricating pump (f) Air intake System :
8.complete unit/set shall be equipped with all standard fitting as per manufacture recommendations and mounted on common base frame with following fitting and rates shall be deemed to be inclusive of the same:- (a) Fly wheel with bousing (b) Cooling system : Mounted radioter with fan and belt (c) Cooling water pump : Centrifucal type belt driven (d) Exhaust gas (i) turbo charger type (ii) Exhaust mainfold, Silencer : (i) Residential type,(ii) Bellows (d) Fuel System: Fuel injection system with fuel injectors fuel injection solenoid switch/nozzle/governer electronic type capable for 1% speed/frequency reglation.fuel filters,fuel hoses(e)Lub oil System:(i) Lubricating oil filter (ii) Lubricating pump (f) Air intake System :
(i) Air intake Manifold (ii) Air cleaner dry type (g) Governer : Electronic Governer with actuator (h) Starting System : Electric Self starter with maintenance free batteries including battery charging alternator (j) Batteries : maintenenace free batteries of 12 Volt /24 volt as per manufacturer direction complete with copper conductor multistranded lead of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electronic all as specified. Starter gear ring, start and stop push button , ignition key/switch,(k) Handing and operation : Sailent features of accessories shall be as under :-Radiator with blower fan , Corrosion inhibitor coolent, paper element filter for fuel, lub oil and by pass, Elecronic governer controlled direct fuel injection system, Fly wheel housing and fly wheel (k) Generator Monitoring Panel : Comprising of following:- (i) Microprocessor based genset controller for metering, monitoring,governing and protection (ii) Engine protection for low oil pressure, high coolent temperature (alarm & shutdown) (iii) Alternator protection parameter like under voltage, over current, under frequency, over frequency, (alarm & shutdown) (iv) Relay drivers for remote annuciations (v) Cyclic cranking (vi) Auto/manual strat/stop (vii) Operator within a temperatur ( range (-20 to 60 degree C) and humidity upto 95%
(viii) Remote monitoring capacity throught separate interface moudules (m) Genset metering parameters like lube oil pressure, coolent temperature, engine speed (RPM), run hours, DC voltage, intake manifold temperature, 3 phase volts and 3 phase amperes,frequency, KW,KVA, power factor. (n) Safety Controls :- Engine low lube oil pressure, high water temparature and over speeding of engine (o) Coupling arrangement : Flexible coupling, fly wheel to suit flexible coupling fly wheel housing (p) Accessories :- AVM pads builts or separately mounted to manufacture base frames.(q) Base frame : Stardy design made of MS channel with necessary reniforcement and predetermined holes. (r) daily service fuel tank of suitable capacity as per manufacturer's instruction of having min fuel storing cap of 12 hours for running DG set including fuel oil indicating gauge drain and vent plug etc complete on a common base within the acoustic enclosure.
Supply laying and testing for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 150 Sqmm 3.5 core ISI marked laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note :- Earth work, brick protection and sand cushioning shall be measured and paid for separately
Supply and fixing off LOAD change over switch with fixing arrangements 415V in sheet metal enclosures cubical type 4 pole of capacity 160 Amps with rotary handle complete all speciified and directed .
Supply and fixing Off LOAD change over switch with fixing arrangements 415V in sheet metal enclosures cubical type 4 pole of capacity 100 Amps with rotary handle complete all speciified and directed .
Supply, install, test & commission LT panel outdoor type, dust & Vermin proof self supporting fabricated out of CRCA steel sheet 3 mm thick at outer cover and 1.6 at inner compartment of size 1200 X 2000 X 450 ( l x b x h) mm with base ISMB 100 mm and Angle Iron frame (50x50x5mm) support to mount panel and tightened with 06 Nos 30 mm x 15 mm bolts & nuts with 4 Legs 30 cms below & 30 cms above GL grouted in PCC 1:3:6 Type C2 , cubicle type floor mounting, suitable for 3 phase 4 wire, 415 V, 50 Hz, AC supply, having cable ally on both sides of panel independant bays for incomming & outgoings with openable from front, rear, left & right side . Duly painted with powder coating (10 tank process) and PU gasket . Cable lugs are to be used to terminate cables/wires. Existing incomming connections are to be re-arranged as directed by Engineer-in-Charge. Single core copper cables shall be used for connections from bus bar to MCCBs/MCBs/instuments etc.
M & L for earthing complete with galvanised steel earth plate electrode 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate,with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.5 of MES SSR Part-1 and specified including provision of earth wire protected by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium grade GI pipe,and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc.and testing on completeion complete all as spec ified and directed. NOTE: The quoted rate of earthing shall be deemed to included cost of 7.5m long galvanised earth strip 32x6 mm and protection pipe of 40 mm bore medium grade ISI marked,GI medium grade ISI marked 20mm bore watering pipe.
S & F for Galvanised iron strip 32 x6 mm buried in ground complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5m deep soft/loose soil for laying of underground cable, foundation of poles & stays etc., and getting out, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified
M & L for removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified.
Sub class ‘B brick,well burnt old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
Supply laying and testing for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 70 Sqmm 3.5 core ISI marked laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note :- Earth work, brick protection and sand cushioning shall be measured and paid for separately
M & L for PCC 1:2:4 Type B-2 (using 40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M/S INDERPAL SINGH
ALCO ENGINEERSPVT LTD
M/S ASHRAF CONSTRUCTIONS
M/S Khan Hussain & Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .