Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.4 LAccepted-AOC 5 45 10A PALACE ENCLAVE ARAMANE BAGILU ROAD NEAR VENKATRAMANA TEMPLE DAKSHINA KANNADA KARNATAKA 574227 INDIA | DAKSHINA KANNADA | KARNATAKA | 574227 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹26.1 L+₹40,619.50 (1.58%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST |
Tender Value
₹30.9 L
EMD Value
₹61,800
Closing Date
6 Mar 2024, 6:00 pmClosed
Col AK Tripathi CWE
HQ CWE ARMY BANGALORE 101 Dickenson Road Bangalore 560042
SPECIAL REPAIRS TO PASSENGER LIFT NO. 1 AND 4 INSTALLED AT FMCC UNDER GE (SOUTH) BANGALORE
2024_MES_640326_1
86237/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HQ CWE ARMY BANGALORE
AS PER TENDER
9 documents required · 9 mandatory
₹500
Yes
GE (SOUTH) BANGALORE
₹61,800
Yes
8 Apr 2024
2 Feb 2024
13 Mar 2024
2 Feb 2024
6 Mar 2024
16 Feb 2024
2 Feb 2024 - 9 Feb 2024
Amount
Supply ,Fixing,testing and commissining in replacement of Control panel with Automatic Rescue Device(ARD) of 7.5 HP ,controllers consisting of motherboard PCB, interface PCB, AC to DC supply conversion PCB, transformers,etc suitable for 8 passenger lift (544 kg capacity) , G+5 = 06 landings installed at Block No.1 & 4 at FMCC complete including UPS, batteries ,etc all as specified and directed .
Material & labour required for replacement of Main Machine motor unit of 5.5KW/7.5HP suitable for 8 passenger capacity lift complete including replacement of old unserviceable nut and bolts, including placing of safety cover to machine unit pully and movable parts etc. all as specified and directed. Make Montanari or as recommended by OEM
Material & labour required for replacement of door motor unit suitable for 8 passenger capacity lift for smooth operation for closing the door which is coupled with door drive complete all as specified and directed. Make as recommended by OEM
Supply & Fixing in replacement of Door drive of suitable capacity for 8 passenger lift (544 kg capacity) , G+5 = 06 landings installed at Block No.1 & 4 at FMCC complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Supply & Fixing in replacement of Full Height Infra Red Door Beam sensor of suitable capacity for 8 passenger lift (544 kg capacity) , G+5 = 06 landings installed at Block No.1 & 4 at FMCC complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Supply & Fixing in replacement of Car Operating Panel (COP) PCB for the operation of Lift Car call button inside the lift cabin as suitable for controller system suitable for 8 passenger lift (544 kg capacity) , G+5= 06 landings installed at Block No.1 & 4 at FMCC complete including UPS, batteries ,etc all as specified and directed by Engr-in-charge.Make as recommended by OEM
Supply & Fixing in replacement of Landing Operating Panel (LOP) PCB for the operation of Lift landing call button as suitable for controller system suitable for 8 passenger lift (544 kg capacity) , G+5- 06 landings installed at Block No.1 & 4 at FMCC complete including UPS, batteries ,etc all as specified and directed by Engr-in-charge.Make as recommended by OEM
Supply, fixing and testing in replacement of Pit Buffer spring complete all as specified & directed by Engr-in-charge. Make as recommended by OEM
Supply & Fixing in replacement of Pit Ladder for inspection of bottom of the lift cabin complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Supply, fixing and testing in replacement of pit switches to control the lift complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Supply, fixing, and testing in replacement of Read Switches for the floor levelling operation of the lift – Read switches NC switches, 24 V complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Supply, fixing and testing in replacement of Car & Counter weight guide shoe complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Supply, fixing and testing in replacement of door rollers & door shoes, complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Supply and installation of floor announcement system complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Supply & Fixing in replacement of Overload sensor of suitable capacity and suitable for 8 passenger lift (544 kg capacity) , G+5 = 06 landings installed at Block No.1 & 4 at FMCC complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Taking down unserviceable steel wire rope and supply and fix new main steel wire rope of 13 mm dia ungalvanised 8/19 construction including necessary connection complete all as specified & directed by Engr-in-charge. Make Usha Martin or as recommended by OEM
Supply, fixing and testing in replacement of LED cabin lights complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Supply, fixing and testing in replacement of emergency light inverter & alarm assembly system complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Supply, fixing and testing in replacement of TOCI/Inspection box and junction boxes as suitable for controller system conforming to IS standard complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Supply, fixing and testing in replacement of Limit Switches for top final switch and bottom slowing limit switch – Limit Switches: NC switches, 110V Top 3 numbers, Bottom 3 numbers complete all as specified and directed by Engineer-in-charge.Make as recommended by OEM
Supply and fixing in replacement of Magnets and Magnet brackets for the sensing operation of reed switches and floor levelling of the lift complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Supply & Fixing of intercom facility at the ground floor and the control buttons should be provided in COP complete including wiring of OFC communication cable all as directed by Engr-in-Charge. Make as recommended by OEM
Supply & Fixing in replacement of Travelling cable of size 0.70 sqmm 12/16 core, 4 runs suitable for 8 passenger lift (544 kg capacity) , G+5 = 06 landings installed at Block No.1 & 4 at FMCC complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Material and labour required for PVC copper 3 core 1.0 Sqmm cablefor wiring of LOPs, gate lock switch, intercom, alarm switch, fireman switch, display, pit stop switch, top final limit switches and bottom slowing limit switch including all necessary connection works 4 complete all as specified & directed by Engr-in-charge.Make as recommended by OEM
Dismantling and taking out unserviceable cabin fan and supply & fixing of new cabin fan of suitable capacity as directed by Engineer-in-chage.Make as recommended by OEM
Supply & fixing in replacement of over speed governor(OSG) complete all as directed by Engineer-in-charge.Make as recommended by OEM
Taking down unserviceable OSG rope and supply and fix new OSG steel wire rope of 8 mm dia ungalvanised 8/19 construction including necessary connection complete all as specified & directed by Engr-in-charge. Make Usha Martin or as recommended by OEM
Supply & Fixing of OTIS safety Standards (OSS) materials which include motor guarding, rope cleaning kit, car top barricade, pit pulley guarding, pit ladder, log out tag out (LOTO) complete all as manufacturers specification.
Material & Labour required for complete buffing of Lift Cabin, Car Door & Landing door to remove complete dirt,dust, rust by completely scrapping the surfaces for good finish of lift
Material & labour required for load testing of lift and obtaining test certificate for elevator running license from authorised service engineer complete all as specified & directed by Engr-in-charge.
Supply & Fixing in repair RCCB 40 amps for earth leakage protection complete all as specified and directed. Make Larsen & Tubro / Legrand / ABB
S&F in repair MCB SP 40 Amps, 240 Volts, complete all as specified and as directed. Make Larsen & Tubro / Legrand / ABB
S&F in repair MCB SP 5 to 32 Amps, 240 Volts complete all as specified and as directed. Make Larsen & Tubro / Legrand / ABB
M & L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all shown in electrical plate No 3 of SSR Pt I including PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways including earth work like excavation, returning filling back disposal etc complete all as specified and as directed.
Supply, laying, testing and commissioning of LT XLPE , insulated armoured, heavy duty, elelctric cable, size 50 Sqmm 3.5 Core with stranded aluminium conductor, 1100 Volts grade conforming to IS -7098 (Part-I) 1988 laid in walls/floors /ducts etc fixed with saddle and clamps or passing through pipes complete with cable ends connection with proper thimbles nut bolts washer all as directed . Make Plaza / Finolex/Polycab / RPG
Material & labour for PCC 1:2:4 type B2 (using 40mm graded stone aggregate ) as in foundation, mass concrete for lift machine foundation etc. complete all as specified and directed.
Demolition of cement concrete any description and in any position not otherwise specially provided for and removing debries out side the MD land complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding and removing debries out side the MD land complete all as specified and directed.
M&L 100 mm thick plain cement concrete 1:4:8 type D-2 as in sub base etc complete all as specified & directed
S&F coloured non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement or coloured cement to match and including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for 20mm thick Granite (of any type ) work (table rubbed and polished) in steps, jambs,pillars,window cills, cooking platform and like laid over and including 20 mm thick screed bed in cement mortar (1:6) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed
M&L for 20mm thick Granite (of any type ) work (table rubbed and polished) for wall lining (veneering to wall) over 12 mm thick backing coat in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed
Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key scrubbing down with water, etc complete all as specified and directed.
M&L rendering 15mm thick in Cm 1:6 on bricksurfaces finished even and smooth without using extra cement all as specified and directed.
M&L rendering 5mm thick in Cm 1:3 on concrete surfaces of ceiling finished even and smooth without using extra cement all as specified and directed.
M&L for preparation ol new plastered surfaces of walls Finishing walls with Acrylic Smooth exterior paint of required shade for new work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
M & L for preparing newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified.
Taking down chowkat or frames with shutter (without taking off shutters from the frame) exc 1.5 sqm but n.exc 4 Sqm etc complete upto 5th floor of bldgs all as specified and directed.
S&F 2nd class hardwood plain, solid, straight chowkats and frames, wrought frame rebated on the solid, rounded or chamfered put together with glue pinned at joints upto 5th floor of bldgs.
S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides upto 5th floor of bldgs .
S&F 150 mm size extruded aluminium alloy handles fabricated type anodized complete upto 5th floor of bldgs all as specified.
S&F stainless steel 100 mm butt hinges for doors complete upto 5th floor of bldgs all as specified.
S&F Aluminium anoidsed barrel tower bolts of extruded section 150mm long.
S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheets cast or extruded sections or cast aluminium alloy complete upto 5th floor of bldgs all as specified.
M&L preparation of old painted surfaces of wood work and joinery exceeding 10 cm width or girth and applying one coat synthetic enamel paint all as specified
M&L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white washing including cleaning of splashes of white wash on floor/objects etc all as specified and directed.
M&L for preparation of old distempered surfaces of walls and applying two coat of Oil bound distemper including stopping of nail holes, filling of cracks, etc and cleaning all window panes from splashes / droppings, upto 5th floor of bldgs all as specified and directed.
S&F in repairs sheet glass ordinary quality 4mm thick in square not exc 0.50 Sqm each pane glazing with oil putty, clip in metal frame and wooden beading in wooden frame complete all as specified.
Carrying out servicing/repairing of electrically operated EOT crane 1 Ton capacity installed at 5 to 8 mtr height form the floor to keep crane serviceable , checking , three monthly by mechanic or at any time if crane gone defective, all electrical control and mechanical mechanism like Gear box motor , plumber block , wheels for LT & CT motion , control panel & resistance box , brake system , limit switch etc. Including servicing /maintainance /repairing with replacement of defective parts with and including , minor parts , tightning of all nut bolts , setting /adjusting of any disbalanced mechanical mechanism , checking electrical connctions/ control swithcs /relays/contactors and wiring , tightning looe connection , calibration of electric controls including testing all mechanism/motors and electricals controls , resistance box etc complete all as directed . Note :- (i) Contractor will get the crane repaired within minimum time after receining complaint either telephonically or in person except for major repair. (ii) Unit rate quoated includes checking , repairing , replacemnt of parts calibration , cost of minor parts , labour charges , transporttion charges and testing except dismantling of mechanical mechanism overhauling . (iii) All spare other than minor will be paid seperately as supply only.
Load testing of following EOT cranes , within in the period of completion by state Govt Authority competent person authorised by Inspector of Factories and furnishing test certificate in accordance with the factories Act of capacity 1 Ton complete all as directed Note :- Load and other reuired items for load test to be arranged by contractor including liason with state authority cost of same is deemed to be included in quoted rate.
Load testing of following HOT cranes, within the period of completion by state Govt Authority competent person authorised by Inspector of Factories and furnishing test certificate in accordance with the factories Act of capacity 1.5 to 5 Ton complete all as directed Note :- Load and other reuired items for load test to be arranged by contractor including liason with state authority cost of same is deemed to be included in quoted rate.
Carrying out servicing/repairing of electrically operated HOT crane 1.5 to 5 Ton capacity having 15 mtr lift installed at 5 to 8 mtr height form the floor to keep crane serviceable , checking , three monthly by mechanic or at any time if crane gone defective, all electrical control and mechanical mechanism like Gear box motor , plumber block , wheels for LT & CT motion , control panel & resistance box , brake system , limit switch etc. Including servicing /maintainance /repairing with replacement of defective parts with and including , minor parts , tightning of all nut bolts , setting /adjusting of any disbalanced mechanical mechanism , checking electrical connctions/ control swithcs /relays/contactors and wiring , tightning looe connection , calibration of electric controls including testing all mechanism/motors and electricals controls , resistance box etc complete all as directed . Note :- (i) Contractor will get the crane repaired within minimum time after receining complaint either telephonically or in person except for major repair. (ii) Unit rate quoated includes checking , repairing , replacemnt of parts calibration , cost of minor parts , labour charges , transporttion charges and testing except dismantling of mechanical mechanism overhauling . (iii) All spare other than minor will be paid seperately as supply only.
Rewinding of 3 phase 415 Volts electric motor of main hoist, creep hoist, long traverse and cross traverse of following capacity with super enamelled copper conductor of gauge as per the existing for the following:-
Electric motor above 1 HP but upto and including 3 HP.
Electric motor Above 3 HP but upto and including 5 HP.
M&L for opening gear box refixing serviceable items and refitting with serviceable items and replacement of defective parts (New parts shall be servicebale items and replacement of defective parts ( New parts shall be measured and paid seperately) including greasing , oiling , testing after refitting etc.
Supply only following items as required for item No.6 above for gear box
Gear Box shaft
Ball Bearings
O rings
Worm qear
Pinion
Supply and fixing in repair Magnetic clutch coil (Big size) for EOT crane matching with existing
Supply and fixing in repair Magnetic clutch coil (small size) for EOT crane matching with existing
Supply and fixing in repair Break shoes for crane movements matching with existing
Supply and fixing in repair Brass wheel /pulley brush for trolly mounted power sources for EOT crane matching with existing
Supply and fixing in repair heavy duty limit switch with 1 NO+2NC auxilary contacts complete all as specified and directed matching with existing
Supply and fixing in repair power conactors , 3 pole , AC -3 current rating 18Amps and with auxilary contacts 1 NO+1NC , with coil volateg 110/220/415 volts conforiming to IS /IEC 60947-4-1 & IEC 60947-4-1 complete all as specified and directed .
Supply and fixing in repair Power Contactors 4 pole 25 Amps, 3Ph, 415V (Make: Schnider Electric/ L&T/ BCH)
Supply and fixing in repair Contactors 4 pole 32 Amps, 3Ph, 415V,. (Make: Schnider Electric/ L&T/ BCH)
Supply and fixing in repair Aux contact block for ML Series 1 NO + 1 NC. (Make: Schnider Electric/ L&T/ BCH)
Supply and fixing in repair Illumanated push button switch LED type with accessories. (Make Schnider Electric)
Supply and fixing in repair Cable PVC insulated sheathed with copper conductor of size 4Core 2.5Sqmm with metal hose covered
Supply and fixing in repair Cable PVC insulated sheathed with copper conductor of size 4Core 1.5Sqmm with metal hose covered
Supply and fixing in repair Ball bearing of Size 6208/6209. Make : SKF
Topping up of Gear box oil 90 Grade Servo in sealed containers. (MAKE:- SERVO/CASTROL)
Supply and fixing in repair Steel wire rope of size 10/12 mm dia construction 6x19 Fibre core suitable for EOT/HOT cranes . Make: Usha Martin / Black Nuts / South India wire ropes.
KAALIKA ELEVATORS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .