Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC 2 JORA BAGAN STREET KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹10.0 L+₹47,612 (5.01%)Rejected-AOC 64 CALLIN STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L2 | Rejected-AOC 2nd Lowest Bidder | |
| 3 | L3₹10.1 L+₹57,358 (6.04%)Rejected-Finance 30 DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L3 | Rejected-Finance 3rd Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
27 Sept 2022, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE-I,WKED,PWD
New Secretariat Building,C Block, 4th floor 1, K.S Roy Road, Kolkata- 700001
Construction of (G plus 2)- storied classroom building at Gokhale Memorial Girls College, Kolkata-Electrical Installation work
2022_WBPWD_408668_1
WBPWD/EE-WKED/NIQ-56/2022-23
Open Tender
ELECTRICAL WORKS ORG
Item Rate
45 days
Gokhale Memorial Girls College
Please refer Tender documents.
5 documents required · 5 mandatory
₹19,000
17 Jan 2023
20 Sept 2022
29 Sept 2022
20 Sept 2022
27 Sept 2022
20 Sept 2022
Amount
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
8 Way Enclosure [Make : Legrand Enclosure (607914) or equivalent model of /L&T/Siemens/ Crabtree as approved by E.I.C] [D-11/15]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection
(a) 125 Amp FP MCCB (Make Legrand/L&T/Crabtree/ Siemens as approved by E.I.C) [D-8/10]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [D-10/14]
4 Way Enclosure [Make: Legrand Enclosure (607715) or equivalent model of Siemens/Crabtree/L&T as approved by E.I.C]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
2+14 way Enclosure [Make: Crabtree Enclosure (DCDKSHODCW16) or equivalent model of Legrand/Siemens/L&T as approved by E.I.C] [D-9, D-10/13]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand /Siemens/ Crabtree/L&T as approved by E.I.C) [D-5/6]
(a) 63Amp FP Isolator
(b) 40 Amp DP Isolator
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection [D-6/7]
(a) 6-32 Amps SP MCB
(b) 32 Amps TP MCB
(b) 63 Amps TP MCB
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA as approved by E.I.C) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. [E-20/2]
a) Avg. Run-8mtr [E-20/2(iii)]
b) Avg. Run-10mtr [E-24/1(e)]
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC,to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA as approved by E.I.C) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish [E-20/3]
a) On board [E-20/3/(i)]
b) Avg. Run-6 mtr [E-20/3/(v)]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene/PVC rigid pipe and by the prelaid GI fish wire and making necy. connection as required [E-9/1]
i)3 x 22/0.3 (1.5 sqmm) [ E-9/1(b)]
ii)2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [ E-9/1(s)]
iii) 2x56/0.3 (4 sqmm) + 2x36/0.3 (2.5 sqmm) as ECC [ E-9/1(v)]
iv) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [ E-9/1(y)]
v) 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC [E-9/1(g1)]
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles [E-3/6(a)]
Cutting Channel of size (45 mm x 45 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles [E-3/7(a)]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works [E-16/7]
a) 20mm size [E-16/7(a)]
b) 25mm size [E-16/7(a)]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [F-9]
i) 2.5sqmm [F-5/9(i)]
ii) 4 sqmm [F-5/9(ii)]
iii) 6 sqmm [F-5/9(iii)]
iv) 10 sqmm [F-5/9(iv)]
v) 16 sqmm [F-5/9(v)]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works. [E-17/1]
2 Row 18 Module [E-17/1(f)]
6 Module [E-17/1(b)]
4 Module [E-17/1(a)]
Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works
2 Module [E-17/2(a)]
Supply & Fixing 240 V 6 A Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC) on existing GI Modular type switch board having top cover plate and making necessaryconnections as required. [E-17/3(a)]
Supply & Fixing 240 V 16 A Modular type switch (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required [E-17/3(b)]
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(a)]
Supply & Fixing 240 V, 6/16 A, 5 pin Modular type plug socket (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(b)]
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket with 16A Modular type switch of grey/brown/other colour as approved by the authority/E.I.C (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC), without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-18/9(b)]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Legrand: Myrius/Arterior or equivalent model of Crabtree/ROMA approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. [E-18/10]
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board [D-13/20(a)]
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length [C-2/17]
Fixing the existing LED batten light fitting complete with all accessories on the existing down rod with checknut as per direction of E.I.C
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. [C-2/16]
Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.
(a) 240 mm x 200 mm x 65 mm
Supply & Fixing bakelite / perspex top cover on existing Inspection board by Brass screws
240 mm x 240 mm x 65 mm [E-5/13(f)]
Laying of cable from 3½ core 35 sqmm and upto 50 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting [F-1/2(c)]
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [F-1/2(a)]
Laying of cable after cutting floor/pavement/wall as per GS for the following Sizes.
2.5 to 35 Sq. mm [ 5(i)/ F- 3 ]
35 to 95 Sq. mm [ 5(ii)/ F- 3 ]
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core [F-1/3(a)]
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trench with shifted soil, levelling up and restoring surface duly rammed [F-2/1(b)]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) Cl hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) [1(a)/G-1]
Extra for treatment of soil by using salt & charcoal or coke for plate electrode [3(b)/G-2]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [G-2/4 (b)]
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
No.-4 SWG [G-2/5(a)(i)]
No.-6 SWG [G-2/5(a)(i)]
No.-10 SWG [G-2/5(a)(iv)]
Supplying and fixing compression type gland and finishing the ends of following XLPE / PVC armoured AL. cable (2/4 / 3.5)Core as per GS. [F-4 & F-5]
i) 4 Core 50 Sq. mm [[7(c)/F4 & 8(b-xvi) /F5]]
i) 3 Core 6 Sq. mm [[7(a)/F4 & 8(b-x) /F5]
Supplying & fixing 50mm medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS [F-6/11(c)]
Supplying and fixing 415V 125A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.. (Make-L&T/Siemens as approved by E.I.C] [D-3/4(a)]
Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. [C-3/18]
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint [H-5/H(5)]
Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure on building as per direction of E.I.C [C-3/20(a)]
Fixing only bulk head ceiling fitting on wall /ceiling by screws etc. [C-2/13]
Supply & fixing of Blank Plate for modular box
Supply of Twin fittings [Philips make Cat No. TMC-501 P2xT-LED 22W P3242 or equivalent model of CG / Bajaj / Wipro/Magic as approved by E.I.C] incl. 2 no. 18W Master LED Tube
Supply of Single fittings [Philips make Cat No. TMC-501 P1xT-LED 22W P3241 or equivalent model of CG / Bajaj / Wipro/Magic as approved by E.I.C] incl. 1 no. 18W Master LED Tube
Supply & fixing 1200 mm ceiling fan complete with all accessories, down-rod etc. (except regulator) [Make: ORIENT Summer Cool/New Breeze or equivalent model of CG/USHA as per approval of EIC/Authority]
Supply of 4/3.5/2 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco / Gloster/KEI/Havells as approved by E.I.C]
(i) 4 Core 50 Sqmm
(i) 3 Core 6 Sqmm
Supply & fixing of Indicator for modular box
S&F Timer Control Unit for single phase Split type AC machine assembled with following accessories: - i)12-way double-door(Metal door) SPNDB Box (L & T cat no.-DBSPN012DD or equivalent model of Legrand/ Siemens as approved by E.I.C)-1 no. ii)25A DP 30mA RCCB (Make: L&T Cat no.-BG202503 or equivalent model of Legrand /Siemens ) - 1 no. iii)Digital 24 hour time switch (Make-L&T Cat no.-67DDT0 or equivalent model of GIC/Siemens) -1no. iv)25A 2-pole power contactor (L&T: Type- MU25 ; Cat no.-CS90118 or equivalent model of Siemens/ABB)-1no. v)Melamine terminal block-2 nos. vi)LED indicating lamp (L&T: SIL R 240V)-1 no. vii) ON/OFF Push ---- 2 nos viii) 6 amp auto mannual toggle switch (Make- L&T or equivalent make as approved by E.I.C) ix) S&F Thermal overload Relay(13-22A) (Make-L&T cat no.-CS90207OODO or equivalent model of Siemens/ABB)- 1no. All control circuit wiring would be made by 1x1.5 sqmm FRLS stranded Cu wire(Brand approved by E.I.C) and the I/C & O/G circuit with 1x4sqmm copper wire of suitable length maintaining colour code incl taping, socketing to complete the work.
Supply & fixing automatic single phase AC starter of 25Amp capacity equipped with Timecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.-OPL-3+ or equivalent model of LT/Legrand as per dierction of E.I.C) to be fixed on wall with all fixing accessories complete as to G.S
Supply of 240V 60 W LED street light luminarie complete with Drivers & all accessories and equipped with IP66 Protection (Philips cat no.- BRP062 LED 68 CW SLC S1 PSU or equivalent model of Crompton Greaves/Wipro/Magic as approved by E.I.C) on roof top mini pole incl making necessary connection
Supply of 240V 250 W LED flood light luminarie complete with Drivers, 10kV SPD, all accessories and equipped with IP66 Protection (Make-CG, cat no.- CFS-506-250-57-60D-SL-GL-NSG or equivalent make/model of Philips/Wipro/Havells/Magic or equivalent make/model as approved by E.I.C) as per direction of E.I.C.
Supply & fixing 400 mm full Matel body pedestal fan complete with all accessories [Make: Orient Stand 35 HS or equivalent model of CG/USHA as per approval of EIC/Authority]
Supply of 10watt LED bulkhead with Pressure Die Cast Al housing complete with all accessories and equipped with IP65 protection, suitable for surface and wall mounting applications (Make-CG, cat no.- LBHE-10-CDL or equivalent make/model of Philips/Wipro/Havells/Magic or equivalent make/model as approved by E.I.C)
Add. G.S.T.@ 18% on total value.
Add. LWC.@ 1% on total value
MONDAL ELECTRIC CO.
S. A. ENTERPRISE
technical_803483.pdf
PDF • 0.05 MB
techsummary_803483.pdf
PDF • 0.34 MB
finance_803483.pdf
PDF • 0.03 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_803483.pdf
PDF • 0.05 MB
WorkOrder-NIQ-56-2022-23.pdf
PDF • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .