| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.3 LAccepted-AOC | L1 | Accepted-AOC DUE TO LI BIDDER | |
| 2 | L2₹51.3 L+₹1.4 L (2.71%)Rejected-Finance | L2 | Rejected-Finance REJECTED DUE TO L2 BIDDER | |
| 3 | L3₹52.9 L+₹3.0 L (5.99%)Rejected-Finance | L3 | Rejected-Finance REJECTED DUE TO L3 BIDDER | |
| 4 | L4₹54.2 L+₹4.2 L (8.42%)Rejected-Finance | L4 | Rejected-Finance REJECTED DUE TO L4 BIDDER | |
| 5 | L5₹54.9 L+₹4.9 L (9.88%)Rejected-Finance | L5 | Rejected-Finance REJECTED DUE TO L5 BIDDER |
| Sl No | Description | Qty | Unit | M/S MURPHEW ENTERPRISES L2 | M/S DK TRADERS L7 | M/S SUNRISE CONSTRUCTION AND CO L5 | M/S SM ANSARI L3 | D.P. Traders L6 | M/S ASHOK CONSTRUCTION L4 | M/S R.N ENTERPRISE L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out in hard / dense soil for laying of cable / errection of poles / stay assembly etc complete all as specified and directed. | 384 | Cum | 770 ₹2,95,680 | 775 ₹2,97,600 | 765 ₹2,93,760 | 785 ₹3,01,440 | 775 ₹2,97,600 | 790 ₹3,03,360 | 750 ₹2,88,000 Lowest |
| 2.00 | Returning filling in trenches including spreading, leveling, watering and well ramming in layers n . Exc 25 cm complete all as specified and directed. | 212.5 | Cum | 285 ₹60,562.5 | 280 ₹59,500 | 270 ₹57,375 Lowest | 290 ₹61,625 | 285 ₹60,562.5 | 300 ₹63,750 | 280 ₹59,500 |
| 3.00 | Removing surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. | 171.5 | Cum | 360 ₹61,740 | 390 ₹66,885 | 370 ₹63,455 | 375 ₹64,312.5 | 360 ₹61,740 | 395 ₹67,742.5 | 350 ₹60,025 Lowest |
| 4.00 | M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all s specified and directed . Note:- The total thickness of sand shall be measured 18 cm after punning Low grade aggregate sand should not be used. | 153 | Cum | 2,920 ₹4,46,760 | 3,400 ₹5,20,200 | 3,340 ₹5,11,020 | 2,950 ₹4,51,350 | 3,200 ₹4,89,600 | 3,000 ₹4,59,000 | 2,900 ₹4,43,700 Lowest |
| 5.00 | Supplying and laying reinforced precast concrete cable cover, Class LV, Type-I, flat, size 250mmx150mm x 40mm all as per SSR Part -I complete all as specified and directed. | 18.5 | Cum | 11,600 ₹2,14,600 | 12,600 ₹2,33,100 | 12,200 ₹2,25,700 | 11,800 ₹2,18,300 | 12,000 ₹2,22,000 | 12,000 ₹2,22,000 | 11,500 ₹2,12,750 Lowest |
| 6.00 | Supply and laying galvanised tube (light grade) ISI marked of size 100 mm dia incl all fittings in trenches/ fix on pole/ wall/ floor or laid in position complete all s specified and directed. | 12 | RM | 1,650 ₹19,800 | 1,800 ₹21,600 | 1,700 ₹20,400 | 1,650 ₹19,800 | 1,700 ₹20,400 | 1,680 ₹20,160 | 1,600 ₹19,200 Lowest |
| 7.00 | Description all as per item No 06 above but size 80 mm dia. | 12 | RM | 1,420 ₹17,040 | 1,720 ₹20,640 | 1,680 ₹20,160 | 1,450 ₹17,400 | 1,500 ₹18,000 | 1,450 ₹17,400 | 1,400 ₹16,800 Lowest |
| 8.00 | Description all as per item No 06 above but size 50 mm dia. | 6 | RM | 840 ₹5,040 | 1,160 ₹6,960 | 1,100 ₹6,600 | 850 ₹5,100 | 1,000 ₹6,000 | 900 ₹5,400 | 800 ₹4,800 Lowest |
| 9.00 | M & L road cutting incl necessary excavation 45 cm wide and 90 cm in depth as in trenches in any type of soils/rock for laying HT/ LT UG cable through pipe after laying/ through the cable trenches will be filliing top with M &L PCC 1:3:6 type C-1 using 20mm gradeds stone aggregates from top over 15 cm thick hard good of brokenboulders, 63mm gauge over 15mm bolders 100mm dia over filled and rammed earth to make good the disburbed surface etc complete all as specified and directed. | 30 | RM | 460 ₹13,800 | 560 ₹16,800 | 520 ₹15,600 | 470 ₹14,100 | 500 ₹15,000 | 500 ₹15,000 | 450 ₹13,500 Lowest |
| 10.00 | M & L for cable route indicator of PCC made of size 750 mm x 300 mm x 60mm with embosing with LT LINE on white in synthetic enmeled paint on red back ground all as specified and directed by Engr In Charge. | 40 | Each | 250 ₹10,000 | 400 ₹16,000 | 310 ₹12,400 | 260 ₹10,400 | 300 ₹12,000 | 280 ₹11,200 | 240 ₹9,600 Lowest |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
18 Sept 2025, 9:00 amClosed
GE TENGA
GE Tenga PIN- 790116 C/O 99 APO
PROVN OF LT FEEDER PANEL, LT CABLE NETWORK WITH CONNECTED ITEMS AND PROVN OF ELECTRICAL POWER AUDIT UNDER POWER SMART ARMY MISSION (PSAM) OF E/M UNDER GE TENGA.
2025_MES_727115_1
8051/E8
Open Tender
Civil Works
Item Rate
180 days
GE TENGA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE TENGA
₹93,000
Yes
16 Oct 2025
21 Aug 2025
19 Sept 2025
21 Aug 2025
18 Sept 2025
11 Sept 2025
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth and getting out in hard / dense soil for laying of cable / errection of poles / stay assembly etc complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers n . Exc 25 cm complete all as specified and directed.
Removing surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all s specified and directed . Note:- The total thickness of sand shall be measured 18 cm after punning Low grade aggregate sand should not be used.
Supplying and laying reinforced precast concrete cable cover, Class LV, Type-I, flat, size 250mmx150mm x 40mm all as per SSR Part -I complete all as specified and directed.
Supply and laying galvanised tube (light grade) ISI marked of size 100 mm dia incl all fittings in trenches/ fix on pole/ wall/ floor or laid in position complete all s specified and directed.
Description all as per item No 06 above but size 80 mm dia.
Description all as per item No 06 above but size 50 mm dia.
M & L road cutting incl necessary excavation 45 cm wide and 90 cm in depth as in trenches in any type of soils/rock for laying HT/ LT UG cable through pipe after laying/ through the cable trenches will be filliing top with M &L PCC 1:3:6 type C-1 using 20mm gradeds stone aggregates from top over 15 cm thick hard good of brokenboulders, 63mm gauge over 15mm bolders 100mm dia over filled and rammed earth to make good the disburbed surface etc complete all as specified and directed.
M & L for cable route indicator of PCC made of size 750 mm x 300 mm x 60mm with embosing with LT LINE on white in synthetic enmeled paint on red back ground all as specified and directed by Engr In Charge.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 185 Sqmm 3.5 core with required aluminium cable lugs all as specified and directed.
Description all as per item No 11 above but capacity 120 Sqmm 3.5 core.
Description all as per item No 11 above but capacity 95 Sqmm 3.5 core.
Description all as per item No 11 above but capacity 70 Sqmm 3.5 core.
Description all as per item No 11 above but capacity 50 Sqmm 3.5 core.
Description all as per item No 11 above but capacity 35 Sqmm 3.5 core.
Description all as per item No 11 above but capacity 25 Sqmm 3.5 core.
Description all as per item No 11 above but capacity 16 Sqmm 4 core.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to GI Strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge.
Carrying out bill analysis of APPD electric bills for a period of past 12 months in respect of one takeover point for receipt of bulk HT 33 KV power supply. Note : The entire work from BQO Srl items No 23 to 39 shall be done under Electrical Engineer cum Certified Energy Auditor having category ‘d (vii)’ and all safety regulations shall be complied with. Note: There take over points located in different places
Preparation of road wise inventory of street lights under each switching point indicating number of each type of street light under the switching point.
Carrying out load survey continuously for 24 hours at each takeover point with a portable power analyzer connected through suitable clamp/flex/split core CTs.
Carrying out random load survey for half an hour at each substation(11KV/415V) of any capacity of transformer with a portable power analyzer connected through suitable clamp/flex/split core CTs.
Carrying out random load survey for 10 minutes at street light switching points. Note for item 4 5,6&7: Load survey shall include data on V, A, PF, KVA, KW & THD. If VTHD is higher than 5% and/or ATHD is higher than 10%, IHD shall also be recorded.
Determination of input wattage of each type of street light based on measurement with a power analyzer/ multi meter in respect of 5 Nos of lights for one minute.
Establishing annual energy baseline from analysis of billing data and recorded data in respect of each takeover point and to sub-allocate energy consumption among all the distribution substations.
Carrying out energy audit of buildings of the category of married accommodation of PBOR in Defence services and equivalent accommodation for civillias having lights, fans’ heaters and other appliances through physical inspection and other activities as outlined below:- (a) Preparing room wise inventory of energy appliances/systems like lights, ventlating fans/ceiling fans, and other user appliances and estimating their power demand based on suitable factors of utilization & diversity. (b) Carrying out random load survey at the main panel for half an hour. (c) Assessment of annual energy baseline from the load and usage data and preparation of service wise energy allocation in respect of services like lights, fans and user appliances. (d) Assessment of performance of lighting by measuring lux levels, area of the lit-up space and assessed power demand. (e) Checking building envelope elements like roof, windows and walls of A/C buildings and suggesting cooling/heating load reduction measures. (f) Assessment of performance of other major appliances as applicable. (g) Suggesting energy saving measures (ESMs) including retrofits and O & M practices along with calculations for savings and payback periods. (h) Submission of energy audit report (3 copies) either separately for each building or for a group of buildings as directed by the GE. Notes: (i) 5 bldgs (Quarters) at different pockets as decided by GE shall be checked as sample and the report shall cover energy audit of all similar buildings of this category. (ii) The drawings/plans and other data shall be provided by the Department. The energy audit shall be carried out by a certified energy auditor with the help of suitable portable instruments as per standard practices.
Submission of energy audit report (5copies) containing introduction, system description, SLD, bill analysis, load survey analysis, street light data/analysis, annual energy baseline, substation wise energy allocation and suggested energy saving measures (ESMs) for electric distribution & street light systems along with calculations of savings and simple payback period (SPP) and suggested action plan in respect of the area covered under each takeover point. Notes: (i) The entire work shall be done under supervision of an Electrical Engineer cum Certified Energy Auditor and all safety regulations shall be complied with. (ii) The action plan shall also contain a proposal for measurement and verification (M&V) of the savings from the ESMs. The cost of M&V systems shall be included in the ESM costs and shall be considered in the SPP calculations also.
Ditto as above but for the category of officers of the rank of Lieutenant to Colonel and equivalent in Navy/ AF and civilian officers and with sample check of one building (quarter) in different block/pocket as decided by GE
Ditto as above but for the category of officers of the rank of Brigadier and above and equivalent in Navy/ AF and civilian officers and with sample check of one building (quarter) in different block/pocket as decided by GE.
Carrying out energy audit of OTM category of buildings with plinth area 2000sq mtrs and above, having lights, fans’ heaters, air conditioners/ air conditioning system and other appliances through physical inspection and other activities as outlined below:- a) Preparing room wise inventory of energy appliances/systems like lights, fans, air conditioners and other user appliances and estimating their power demand based on suitable factors of utilization & diversity. b) Carrying out random load survey at the main panel for half an hour. c) Assessment of annual energy baseline from the load and usage data and preparation of service wise energy allocation in respect of services like lights, fans, air conditioners and user appliances. d) Assessment of performance of lighting by measuring lux levels, area of the lit-up space and assessed power demand. e) Checking building envelope elements like roof, windows and walls of A/C buildings and suggesting cooling/heating load reduction measures.f) Assessment of performance of room air conditioners in terms of KW/TR by measuring parameters like temperatures and power consumption etc. g) Assessment of performance of other major appliances as applicable. h) Suggesting energy saving measures (ESMs) including retrofits and O & M practices along with calculations for savings and payback periods. i) Submission of energy audit report (3 copies) either separately for each building or for a group of buildings as directed by the GE. Notes: i. The energy audit shall be carried out in respect of 20 buildings. List of buildings shall be shown separately. ii. The drawings/plans and other data shall be provided by the Department. The energy audit shall be carried out by a certified energy auditor with the help of suitable portable instruments as per standard practices. iii. Assessment of performance of central/package type A/C systems is not included in the energy audit of buildings as the same is covered separately.
Carrying out energy audit of Main Receiving station at 3 pockets of any capacity including measuring /recording power (KW), Voltage, Amps, PF and checking of disribution system, load balanceing and submission of three copies of the energy audit report containing measured data, analysis, recommended saving measures and their economic analysis in terms of payback period. Note: Nameplate data of all euipments in MRS and historic data of its usage shall be provided by the Department. The energy audit shall be carried out by a certified energy auditor.
Carrying out energy audit of standby DG sets of any capacity including test running of the DG set for 30 minutes at a loading at which the DG set is generally run during most of the time and measuring /recording power (KW), Voltage, Amps, PF and diesel consumed and submission of three copies of the energy audit report containing measured data, analysis, recommended saving measures and their economic analysis in terms of payback period. Note: Nameplate data of the DG sets and historic data of its usage like hours run, KWh generated and diesel consumed shall be provided by the Department. The energy audit shall be carried out by a certified energy auditor.
Carrying out energy audit cum efficiency testing of water pumps/back wash pump of any type and any capacity by measuring and logging flow and power data including assessment of actual system head and determination of hydraulic (wire to water) efficiency and submission of 3 copies of report containing logged data, test results of pump efficiency test, analysis of test results/data, remarks on power quality and suggested energy saving measures (ESMs), savings and payback period etc.
Supply, fixing, and testing of 33 KV HT Feeder as Category “A” Feeder Meter AC, 3 Phase, 4 Wire, CT,PT operated lag plus lead only fully static and AMR compatible Tri-Vector Energy Meters for measurement of different electrical parameters listed elsewhere in the document including Active Energy (KWH/MWH), Reactive Energy (KVARH/MVARH), Apparent Energy (KVAH/MVAH) etc confirming to IS-14697:1999(2004), and IS-15959:2011
Supply and fix LT AC 3 Phase, 4 wire, 50/5 Amps and 100/5 Amps & -/ 5 Amp CT operated fully static AMR compatible TOD tri-vector net energy meter as per catetgory C1 of IS:15959 / 2011 complete
M/S MURPHEW ENTERPRISES (BID ID -3425111)
M/S SM ANSARI (BID ID -3425368)
M/S ASHOK CONSTRUCTION (BID ID -3424511)
M/S SUNRISE CONSTRUCTION AND CO (BID ID -3426713)
D.P. Traders (BID ID -3426646)
M/S DK TRADERS (BID ID -3427531)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .