Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC | ₹2.3 Cr | L1 | Accepted-AOC LOWEST BID VALUE |
| 2 | L2₹2.5 Cr+₹24.3 L (10.8%)Rejected-Finance HATIA ROAD DANGALPARA DISTT DUMKA JHARKHAND PIN 814101 | DUMKA | DUMKA | JHARKHAND | 814101 | ₹2.5 Cr+₹24.3 L (10.8%) | L2 | Rejected-Finance HIGHER BID VALUE |
| 3 | L3₹3.2 Cr+₹91.5 L (40.4%)Rejected-Finance | ₹3.2 Cr+₹91.5 L (40.4%) | L3 | Rejected-Finance HIGHER BID VALUE |
| 4 | L4₹3.3 Cr+₹1.0 Cr (45.4%)Rejected-Finance KHEMASULI P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPUR WEST BENGAL | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | ₹3.3 Cr+₹1.0 Cr (45.4%) | L4 | Rejected-Finance HIGHER BID VALUE |
Tender Value
Refer Docs
EMD Value
₹2.6 L
Closing Date
8 Sept 2021, 6:55 pmClosed
CWE AF KALAIKUNDA
CWE AF KALAIKUNDA , KALAIKUNDA AIRFIELD POST, DIST WEST MEDINIPORE,721303
COMPLETION OF INCOMPLETE WORK FOR PROVISION OF DEFICIENT LIVING IN ACCN FOR TRAINEE OFFICERS
2021_MES_464339_1
8411/RC/KKD(P)/05/E8
Open Tender
Civil Works
Lump-sum
390 days
AT AF STN KALAIKUNDA
Class B, Category a(I)
2 documents required · 2 mandatory
₹1,000
Yes
GE (P) AF KALAIKUNDA
₹2.6 L
Yes
23 Oct 2021
31 Jul 2021
10 Sept 2021
31 Jul 2021
8 Sept 2021
21 Aug 2021
1 Aug 2021 - 12 Aug 2021
Amount
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of double storied 12 No. single officers Accn (Flt Lt & Flg Offr) including garage with permanent specification complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of double storied servant quarter with permanent specification complete all as specified and shown in drawing.
Sch 'A' Sec -I (Building work) Note:- This schedule is not pre-priced by MES and the pre-priced rate as "Rs. 0.00" indicated under Col.5. signifies this fact only Construction of Sub station building with permanent specification complete all as specified and shown in drawing.
Total amount of Sch 'A' Part-II (Site clearance and earthwork) Prepriced amount B/F from Sl page No. 23
Total amount of Sch 'A' Part-III (Internal Electrification) Prepriced amount B/F from Sl page No. 26
Total amount of Sch 'A' Part-IV (Internal water supply) Prepriced amount B/F from Sl page No. 27
Total amount of Sch 'A' Part-V (Road ) Prepriced amount B/F from Sl page No. 29
Total amount of Sch 'A' Part-VI (Path) Prepriced amount B/F from Sl page No. 30
Total amount of Sch 'A' Part-VII (External water supply) Prepriced amount B/F from Sl page No. 32
Total amount of Sch 'A' Part-VIII (External electric supply) Prepriced amount B/F from Sl page No. 35®
Total amount of Sch 'A' Part-IX (Light Conductor) Prepriced amount B/F from Sl page No. 36
Sch 'A' Part-X (Misc Items) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.5 signifies this fact only.
S & F water jet spray for EWC compete all as specified and as directed
Supply & fixing double door MCB DB SPN horizontal type for single phase outgoing made of steel sheet phosphatised powder painted,240 Volt with busbar rated 200 Amp, neutral link, Earth bar and Din Rail and having IP 42 Protection for size 6 Way. compete all as specified and as directed
Supply & fixing double door MCB DB TPN , VTPN, MCCBs as incomer type and single phase outgoing made of steel sheet phosphatised powder painted,440 Volt with busbar rated 200 Amp, neutral link, Earth bar and Din Rail and having IP 42 Protection for size 4 Way, Incomer is 3 pole V-Tec MCCB of 100Amp rating 25kA breaking capacity. MCCB is pre fitted at factory & included in price list all as specified and directed by Engr-in-Charge complete as specified and as directed by Engr-in-Charge
Supply and fixing MCB single pole 6 to 32 Amp with rupturing capacity 10 KA, C series complete all as specified and directed by Engineer in Charge.
Supply and fixing MCB single pole 40 Amp with rupturing capacity 10 KA, C series complete as specified and as directed by Engr-in-Charge
S/F MCB single pole and Neutral 6 to 32 Amp with rupturing capacity 10 KA , C series complete all as specified and as directed by Engineer in Charge.
S/F MCB single pole and Neutral 40 Amp with rupturing capacity 10 KA , C series complete all as specified and as directed by Engineer in Charge.
S/F MCB triple pole and Neutral 63 Amp with rupturing capacity 10 KA , C series complete all as specified and as directed by Engineer in Charge.
S/F MCB triple pole 40 Amp with rupturing capacity 10 KA , C series complete all as specified and as directed by Engineer in Charge.
S&F LED tube light fitting 20 watt capacity including OEM T/L surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarboate diffuser & integrated electronic driver Fixture size in mm 1200x108x62 complete all as specified and as directed by Engr-in-Charge.
Supply and fixing as building security light 25watt Energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistance of IK07 complete all as specified and as directed by Engr-in-Charge.
M&L for street light bracket (suitable for LED fittings upto 1.5 RM make out of GI pipe of medium grade 40mm dia proper shaped, bended, threaded and drilling holes for wire entry and MS clamp of suitable size in proper shape complete and all as directed and specified by Engineer-in-Charge.
S&F ceiling fan of 1200 mm sweep, 240 volts, 50Hz, high speed with BEE rated 5 star and connecting up including provision of cable from ceiling rose or connector to fan with flexible copper cable of suitable size complete all as specified and as directed by Engr-in-Charge.
S&F ceiling fan of 1400 mm sweep, 240 volts, 50Hz, high speed and connecting up including provision of cable from ceiling rose or connector to fan with flexible copper cable of suitable size complete all as specified and as directed by Engr-in-Charge.
S&F heavy duty metallic exhaust fan 230 mm sweep, 240 Volts, 1400 RPM with louver and connecting up including provision of cable from celing rose or connector to fan complete all as specified and as directed by Engr-in-Charge.
S&F Sleek 1x5 Watt Linnet sleek LED mirror lihgt provider with high output diffuser including accessories complete as specified and as directed by Engr-in-Charge
Supply and fixing LED Lamp 7watt complete all as specified & directed
S&F LED Bulkhead luminaries 10 Watt , 230 Volts, IP-65, fixing on wall including connection complete all as specified and as directed by Engr-in-Charge.
Supply and fixing wall mounted bedside/reading lamp 3 watt, lamp size 13.4cm X 12.4 cm X 8.2 cm made of metal and synthetic, white colour, 240volts complete all as specified and as directed by Engr-in-Charge.
M&L sub main wiring (concealed type) in & including PVC Rigid conduit of 32mm dia with four single core FRLS PVC insulated unsheathed cable, 1100 volts, grade having multi stranded copper conductor of 16 sqmm nominal cross sectional area each drawn into and all accessories including two Nos single core 16 sqmm copper conductor for earth continuity conductor connected to earth dolly complete all as specified & as directed by Engr-in-Charge. (Note - Four run single core cable, Two run of earth conductor and one run on PVC conduit shall be measured as a unit length.)
M&L sub main wiring (concealed type) in & including PVC Rigid conduit of 25mm dia with four single core FRLS PVC insulated unsheathed cable, 1100 volts, grade having multi stranded copper conductor of 10 sqmm nominal cross sectional area each drawn into and all accessories including two Nos single core 10 sqmm copper conductor for earth continuity conductor connected to earth dolly complete all as specified & as directed by Engr-in-Charge. (Note - Four run single core cable, Two run of earth conductor and one run on PVC conduit shall be measured as a unit length.)
M&L sub main wiring (concealed type) in & including PVC Rigid conduit of 20mm dia with two single core FRLS PVC insulated unsheathed cable, 1100 volts, grade having multi stranded copper conductor of 6 sqmm nominal cross sectional area each drawn into and all accessories including one No single core 6 sqmm copper conductor for earth continuity conductor connected to earth dolly complete all as specified & as directed by Engr-in-Charge. (Note - Two run single core cable, One run of earth conductor and one run on PVC conduit shall be measured as a unit length.)
M&L sub main wiring (concealed type) in & including PVC Rigid conduit of 20mm dia with two single core FRLS PVC insulated unsheathed cable, 1100 volts, grade having multi stranded copper conductor of 4 sqmm nominal cross sectional area each drawn into and all accessories including one No single core 4 sqmm copper conductor for earth continuity conductor connected to earth dolly complete all as specified & as directed by Engr-in-Charge. (Note - Two run single core cable, One run of earth conductor and one run on PVC conduit shall be measured as a unit length.)
Supply, installing, testing and commissionning indoor type LT Panel board wall mounted, semi concealed type, factory made, totally enclosed, dust and vermin proof, made of 2mm thick (14 gauge) thick CRCA sheet and having dimention of 800mm x 500mm x 300mm duly fabricated and painted with two coats of 1st quality synthetic enamel paint (shade : Ivory) over a coat of red oxide metal primar duly sprayed over the surfaces and suitable for AC 415 Volts, 50 C/S, 3 Phase, 4 wire system all as shown on drawing and comprising of the following:- INCOMING MCCB 415 Volts, 3 Phase, 50 C/S, 4pole, 160 Amps with breaking capacity 36KA with adjustable type thermal and magnetic setting - 01 No (Make : Legrand (Type - DPX 160, Cat No - 420087) BUSBAR Bus bars shall be made of tinned copper strip of size 40mm x 6mm ( 700mm long) rigidly mounted on bakellite busbar insulator of suitable size and busbars shall be covered with PVC sleevings of standard colour code - 4 Nos OUTGOINGS MCCB 415 Volts, 3 Phase, 50 C/S, 4pole, with breaking capacity 16 KA with adjustable type thermal and magnetic setting of following ratings :- (a) 63 Amps - 2 Nos (Make : Legrand DPX 160 , Cat No 420003) (b) (a) 40 Amps - 1 Nos (Make : Legrand DPX 160, Cat No 420002)
M&L of 150mm SGSW pipe laying in trenches in including excavation on soft/loose soil,average depth 1.5m packing under and hunching with cement concrete 1:2:4 type B-1, hunching 3/4 section complete all as directed by the Engr-in-Charge at site.
M&L RCC pre-cast manhole cover of cement concrete 1:2:4 type B-1 using 8mm MS bar and with MS angles for fixed in position etc complete all as specified and directed.
Cutting into existing manholes for connecting drains making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B1 smooth finished and reforming benching of size 150mm dia etc complete all as specified and directed.
S/F Test point terminal enclosure polycarbonate size 200mmx200mmx98mm etc complete all as specified and directed.
Supply, fixing, jointing and testing for 80mm dia cast iron sluice valve, class 1.0 PN with iron wheel and gun metal spindle (confirming to IS- 14846 upto new revision) Flanged end including necessary nut, bolt, washer, gasket complete all as specified and as directed
M&L for construction of brick masonry valve pit of size 90cm x 90 cm x 90cm (internal dimension) with one brick thick P.C.C 1:4:8 type D-2 (using 20mm graded crashed stone aggregate) as in foundation concrete incl PCC (1:3:6) type CI (using 20mm graded crashed stone aggregate) as in bedding and coping 10mm thick cement plaster in Cement mortar (1:4) internally & externally upto 15 cm below ground level providing valve pit 50x50x6mm angle iron frame all round the fixed point by means of 4 Nos hold fast 150mm long made out of flat iron 40 x 6 mm embedded in PCC block (1:2:4) type B-I (using 20mm graded crashed stone aggregate) of size 230 x200 x100mm. incl provn of hing welded with angle iron frame and Mild Steel cover 3 mm thick, Mild steel handle of suitable and size welded with Mild Steel cover & suitable locking arrangement & applying two coats of synthetic enamel paint over a coat of red-oxide primer incl necessary excavation work in soft/ loss soil complete all as specified & directed
M & L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick directly in ground(Earth plate do not less than 2.25M in deep below groundlevel) with top edge of the plate not less than1.5m below normal ground level connected to GI wire 4mm dia by means of bolts, nuts, check nuts and washers of brass/copper or all as shown in electrical Plate No 3 and connected to earthing test point all as specified and directed including necessary earth work in any type of starta and PCC 1:3:6 type B1 for chamber and RCC chamber cover 50mm thick lieu of CI cover and GI wire protected by 15mm GI pipe med grade complete and 50mm internal dia GI pipe med grade 20 mm bore for watering pipe and GI funnel with wire mesh complete all as specified and as directed.
M&L for Earthing complete with copper earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to copper strip of size 32 x 6mm earth lead by means brazing after fixing of nuts, bolts, check nuts, washers of copper, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of with locking arrangement , reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion complete all complete as specified and directed. (Copper strip upto 7.5 Rm will be included in this item rate and copper strip beyond 7.5 Rm will be measured sepriately. Note: (Fresh soil will be laid below 60cm from ground level and connected to test point through plinth protection necessary cost of repair to plinth protection and brazing and welding deemed to be included in item and connected through double nut bolt and brazing of joints.)
M&L for Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15mm thick buried directly in ground with earth pit not less than 3.25 meter deep below ground level with top edge of plate not less than 2.60 meter below normal ground level connected to copper strip of size 20 x 3mm earth lead by means brazing after fixing of nuts, bolts, check nuts, washers of copper, protected by galvanized iron pipe 32mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of with locking arrangement , reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion complete all complete as specified and directed. (Copper strip upto 7.5 Rm will be included in this item rate and copper strip beyond 7.5 Rm will be measured sepriately. Note: (Fresh soil will be laid below 60cm from ground level and connected to test point through plinth protection necessary cost of repair to plinth protection and brazing and welding deemed to be included in item and connected through double nut bolt and brazing of joints.)
Supply, installation, testing and commissioning of Power transformer, capacity 100 KVA step down indoor type floor mounting, double copper wound core type 3 phase 50 c/s AC supply of , oil immersed with ONAN type cooling with external cooling tubes/radiators having no load voltage ratio 11KV/0.433 KV ( corresponding to principal tapping) delta connected on primary side (HV incoming) and star connected on seconery side (secondary out going) corresponding to vector group Dyn 11confirming to IS-2026-1977 or latest IS, and having, off load tap changer in the steps of 2.5% on HV side to take care of voltage from +/- 7.5, +/- 5, +/- 2.5 volt, to give output on 433V secondary side and including initial oil filling of transformer oil upto appropriate level and complete with standard fittings all as specified in particular specifications:- (a) Conservator with oil gauge, filling hole with plug and drain hole with plug. (b) 01 No of prismatic oil level guage mounted on conservator wall with first fill of charge upto maximum level. (c) Silica gel dehydrating breather with oil seal and with first fill of charges. (d) Pressure release valve with automatic reseting arrangement after release of pressure- 01 set (e) Adequate No of thermometer pocket incuding one thermometer.
Item No 46 Cont........ (f) Top oil filter valve. (g) Bottom oil filter cum drain valve. (h) Rating diagram and terminal marking plate. (j) Earthing terminal - 02 Nos (k) Lifting lugs for transformer - Two (l) Jacking pads- 01 set (m) Under carriage with 4 Nos of plain rollers. (n) Air release plug on main transeformer tank. (o) Adequate Nos of cooling radiators. (p) 150 mm dial type oil temperature indicator with maximum read pointer and resetting device. (q)150 mm dial type winding temperature indicator with maximum read pointer and resetting device (r) Air insulated cables box on HV and LV side. NOTE - Pre- commissioning test of the transformer shall be done by SEI . All arrangement for testing shall be made by the contactor without any extra cost to the Govt complete all as specified and directed by Engineer-in-Charge on site.
M&L for Boring hole under the road below 1.5 mtr from the road/hard surfaces suitable for inserting HDPE pipe of 80mm to 100mm dia by trenchless technology using necessary equipment including necessary machine without damaging the existing road and getting out in any type of soil and disposal of soil a distance n exc 50 mtr from the site of work complete all as specified and directed.
Supply & laying old size Fly ash bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-charge
M&L for precast RCC (1:1.5:3) type A1 (using 20mm graded stone agg) cover slabs of size 300 mm wide and 600mm hieght and 100 thick oval shape on top. The precast slab shall be embeded 300mm below GL in PCC (1:3:6) of size 310mm x 150mm x 300mm including engraved the words in capital letters of size 5 cm height and 2cm width HT 11 KV Cable/cabel joint including necessary surface finish with plastering 10 mm thick in CM (1:3) and two coats of synthetic enamel paint over a coat of primer including necessary excavation of size 310mm x 150mm x 300mm and removing complete all as specified and as directed.
S&F Steel tubular swaged poles for street light fitting complete with 1.5mtr long bend shape 40mm dia light grade GI pipe, bracket with MS clamp of suitable size, cast iron base plate, finial taper plug, bolts, nuts & screws including one coat primer and two coats of aluminium paint as specified type 410 SP-22 (8.50 metres long) complete all as specified and as directed.
S&F junction box polycarbonate type with terminals etc complete all as specified and as directed.
Supply and fixing 65 watt LED ,5200 lumens new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light source and exclusively designed polycorbonate cover alongwith electronic driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed
Supply and laying synthetic insulating mat ISI marked synthetic elastomer confirming IS- 15652-2006 category -III tested by CPRI etc suitable for 11KV volts grade of size 2mx1mx2.5mm complete all as specified and as directed by Engr-in - charge.
Supply and fixed lightning arresters HT 11KV for 2 pole structure of rating 9KV normal discharge current 10 KA complete all as specified and directed.
M/S KUMAR AVINASH
M/S. GHOSH CONSTRUCTION
Guru Charan Mahata
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .