| 4 | L4₹17.6 L+₹3.7 L (26.3%)Rejected-AOC PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L4 | Rejected-AOC L4 | |
| 5 | L5₹18.3 L+₹4.4 L (31.7%)Rejected-AOC DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L5 | Rejected-AOC L5 |
Tender Value
₹24.3 L
EMD Value
₹48,500
Closing Date
3 Jul 2023, 6:00 pmClosed
GE (AF) Hakimpet
Secunderabad
REPAIRS AND MAINT OF INTERNAL ELECTRIFICATION OF OTM BUILDINGS AT AFS HAKIMPET UNDER GE (AF) HAKIMPET
2023_MES_601210_1
8534/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hakimpet
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Hakimpet
₹48,500
Yes
11 Jul 2023
5 Jun 2023
5 Jul 2023
5 Jun 2023
3 Jul 2023
19 Jun 2023
Amount
Taking down copper/ aluminum point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, lamp holders, light fittings etc removing materials for taking credit and making good disturbed surfaces of walls, floors etc. including paint touch up to match with the existing surface as per site requirement complete all as specified and directed by Engr-in-Charge.
Taking down existing unserviceable MCCB (any type and capacity) and making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed by the Engineer in charge.
Taking down existing unserviceable distribution board with MCBs, switch fuse unit, enclosureand making good the disturbed surface of walls including paint touchup to match with the existing surfaces complete all as specified and as directed by the Engineer in charge.
Taking down Existing old UNSV submain wiring of any description /type size and removal of UNSV material from site and making good the disturbed surface of walls / ceiling so as to match with the existing finishes all as specified and as directed by the Engineer -in- charge .
M&L for point wiring with 1.5 sq.mm FRLS insulated multistranded copper conductor ,1100 volts grade single core PVC insulated and unsheathed cable drawn through new PVC conduit/casing capping of suitable size but not less than 20 mm dia on surface of stone/concrete wall /roof etc all as per site requirement including FRLS,PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour coding and pressed steel terminal boxes made out of 1.6 mm thick MS sheet with sink into the wall for mounting, 60mm deep covered including laminated sheet cover 3mm thick laminated hylam sheet fixed with cadmium plated screws/PVC gang box fully enclosed type for mounting switches,sockets,fan regulator, etc including making good the disturbed surfaces of walls and paint touch up to match with the existing surfaces as per site requirement complete all as specified and directed by Engineer-in-Charge.
One light point controlled by one switch
One 3 pin 6 Amps socket point controlled by one switch on same board
One 3 pin 6 Amps socket point controlled by one switch on independent board
One ceiling fan point controlled by one switch and regulator
One bell point controlled by one switch and regulator
All as per item No. 5 here-in-before but with 2.5 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with 1.5 sq.mm FRLS insulated multistranded copper conductor ,1100 volts grade single core PVC insulated and unsheathed cable drawn through existing concealed PVC upto 32mm including FRLS, PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour coding and pressed steel terminal boxes made out of 1.6 mm thick MS sheet box, 60mm deep covered with 3mm thick laminated hylam sheet fixed with cadmium plated screws for mounting switches, sockets, fan regulator, etc including making good the disturbed surfaces of walls and paint tuch up to match with the existing surfaces as per site requirement complete all as specified and directed by Engineer-in-Charge.
One light point controlled by one switch
One 3 pin 6 Amps socket point controlled by one switch on same board
One 3 pin 6 Amps socket point controlled by one switch on independent board
One ceiling fan point controlled by one switch and regulator
All as per item No. 7 here-in-before but with 2.5 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of switch piano flush type, single pole one way 6 Amps 240 volts complete all as specified and as directed.
S&F in replacement of bell push,flush type, 6 Amps ,240 Volts ISI marked complete.
S&F in replacement of switch socket combination 2 in 1, 3 pin 6 Amps, flush type, universal ,240 volts complete all as specified and as directed
M & L in replacement of switch socket combination 2 in 1, 3 pin , 6 Amps/16 Amps, flush type,universal,240 volts complete all as specified and as directed
M & L in replacement of Call bell, ding dong, AC 240 Volts
S&F in replacement of stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz 2 module size in 5 steps flush type complete all as specified and directed.
S&F in replacement of stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz single module size in 5 steps flush type complete all as specified and directed.
S & F in replacement of batten/angle holder, PVC/Polycarbonate type with back plate, 240 V , 50 Hz suitable for batten fittings complete all as specified and directed.
S&F in replacement of ceiling rose 6 A, 3 plate,PVC/polycarbonate ,insulated body 240 Volt , 50 Hz complete all as specified and directed.
M&L for submain wiring alongwith earth wire with 3 x 4.0 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through existing PVC Conduit in wall/roof surfaces complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 4.0 Sqmm copper cable shall be measured as one unit length.
All as per item No. 18 here-in-before but with 3 x 6.0 sqmm FRLS PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 6.0 Sqmm copper cable shall be measured as one unit length.
M&L for submain wiring alongwith earth wire with 3 x 4.0 Sqmm FRLS PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC Conduit and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 4.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length.
All as per item No. 20 here-in-before but with 3 x 6.0 sqmm FRLS PVC insulated copper conductor cable complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 6.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length.
M&L for submain wiring alongwith earth wire with 3 x 4.0 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including Steel Conduit and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed by Engineer-in-Charge. Note: Three runs of 4.0 Sqmm copper cable and one run of steel conduit shall be measured as one unit length.
Supply and fix distribution board double door type (for incoming MCCB & outgoing MCBs) TPN 8 way vertical type sheet steel powder painted with bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and directed by Engineer-in-Charge.
All as per item No. 23 above but of TPN 4 way.
Supply and fix MCB distribution board single door type SPN 12 way sheet steel powder painted with bus bar ,neutral link & earth bar etc.with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing circuit complete all as specified and directed by Engineer-in-Charge.
All as per item No. 25 above but of SPN 8 way.
All as per item No. 25 above but of SPN 4 way.
Supply and fix sheet metal powder painted double pole enclosure with a two pin and earth plug and socket flushing in wall including 20 Amps rated double pole MCB 10 KA, "C" curve complete all as specified and directed by Engineer-in-Charge.
Supply and fix sheet metal powder painted triple pole and neutral enclosure with a three pin and earth plug and socket flushing in wall including 32 Amps rated 415 V, three pole MCB 10 KA, "C" curve complete all as specified and directed by Engineer-in-Charge.
S&F MCB Triple pole and Neutral (TPN) of capacity 40-100 Amps 415 volts ,breaking capacity 10 KA,'C' series ,fixed in proper position complete all as directed by the Engineer in charge .
Supply and fix MCB, SPN, 40-63 Amps, 240 Volts
Supply and fix MCB , SP, 6 - 32 Amps, 240 Volts
Supply and fixing MCCB 125 Amp three pole 415 Volt , breaking capacity 16 KA, with fixed thermal & magnetic setting complete all as specified and as directed by the Engineer in charge.
Supply and fixing MCCB 25-100 Amp Three pole 415 Volt , breaking capacity, 16 KA, with fixed thermal & magnetic setting complete all as specified and directed by the Engineer in charge.
Supply & fixing wall mounted LED batten fittings extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 22W LED (4ft) complete with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete including taking down old U/s fittings complete all as specified and directed by Engineer-in-Charge.
Supply & fixing wall mounted new E-Lite LED Triyca batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver 10W LED 6500K (2ft) complete with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete including taking down old U/s fittings complete all as specified and directed by Engineer-in-Charge.
S&F LED light fitting in replacement of ,10 watt bulk head luminaries complete with all accessories and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply & fixing high efficacy recess luminaire in replacement of suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extrured diffuser giving glare free light and good aesthetic appeal 18 W LED 6000K (1ft X 1ft) complete with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge. Make :- Havells Cat No. LHEAAWP7IL1W018 or its equivalent in Philips/CG.
Supply & fixing in replacement of high efficacy recess luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extrured diffuser giving glare free light and good aesthetic appeal 35/36 W LED (2ft X 2ft) complete with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of high efficacy recess luminaire box type suitable for high brightness 18 W LED complete with all accessories including connecting up with three core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
Disconnecting ceiling fans of any sweep and from any height including electrical connections, bringing down, dismantling, opening up, cleaning internally and externally, overhauling by replacing unserviceable items such as split pins, bearings, bushes, copper flexible cord, cotter pins and check nuts etc, lubrication with approved lubricants, reassembling including replacement of worn-out /defective parts and refixing for smooth functioning and connecting cable from ceiling rose to fan including testing complete all as specified and directed by the Engineer-in-charge.
Description all as per Ser item No.41 above here before but exhaust fan /wall mounting fan/Padestal fan of sweep 230/300/375/450 mm complete all as specified and as directed by the Engineer-in charge.
Notes for item No 41 & 42:- Replacement of unserviceable spare part required for servicing/overhaulingand rewinding of fans shall be measured and paid separately under relevent items after testing and commissioning vide relevent Item of this schedule.
Supply only the following parts in replacement of Ceiling/ Exhaust Fans of existing makes and size complete all as specified and directed by the Engineer-in Chargre :-
Capacitor 2.5 mfd capacity 240 volts. Make : CAPCO/TIBCON
Ball bearing of suitable size. Make : NBC/SKF/TATA.
Gun metal bush
Copper flexible cord 3 core of size 23/00076
Fan Clamp with rubber bush
Down rod, 400 mm long
Painting of Fan of any size and make.
Capacitor 4 mfd capacity 240 volts . Make : CAPCO/TIBCON
Ball bearing for exhaust fans of suitable size . Make : NBC/SKF/TATA
Taking out burnt copper winding wire from fan, cleaning the rotor shaft properly and rewinding with new super enamelled copper winding wire as per existing size/ gauge including heating/ varnishing etc complete as per manufacturer's design for the following fans:-
Ceiling fan of 1200/1400 mm sweep
Exhaust fan of 230/300 mm sweep
Exhaust fan of 375/450/305/380 mm sweep
Wall mounting/Padestal fan of 400/450 mm sweep
S & F in replacement of louvers with suitable frame work and fixing arrangements for exhaust fan of any size sweep complete including removing the existing unserviceable one complete all as specified and directed by the Engineer-in-Charge.
S & F in replacement of flap cover with suitable frame work and fixing arrangements for exhaust fan of size 230/300/450 mm sweep complete including removing the existing unserviceable one complete all as specified and directed by the Engineer-in-Charge.
Taking Down water heater (Electric Geyser) storage type of any make of 25 / 50 ltr capacity after disconnecting the existing electrical connection, water pipes and reassembling in all respects after replacing unserviceable parts/components and testing for proper working after repairs and refixing in the original place/position duly connecting up water supply and electric supply etc.complete all as specified and as directed by the Engineer-in-Charge.
Note :- Spare parts replaced shall be measured and paid separately under relevent items below. However labour cost of replacement is deemed to be included in the rate quoted.
Supply only the following parts in replacement of water heater (Electric Geyser) storage type of given make and size complete all as specified and as directed by the Engineer-in Chargre :-
Thermostat suitable for 25/50 litre capacity . Make -sphare hot /bajaj/ditz/picco/usha /racold .
Heating element 1500 watt 240 volts push/thread type circular/ triangular base for any make and type Make - Bajaj / Racold
Heating element 2000 watt push/thread type circular /triangular base suitable for any make and size. Make - Bajaj / Racold
Indicator bulb 240 V suitable for given make, type and model
S & F in replacement of pressure release valve suitable for 25/50 litre capacity geyser including taking out the existing unserviceable one complete all as specified and directed by Engineer-in-Charge. Make -Sphare hot /bajaj/ditz/Picco/usha .
S & F in replacement of gasket rubber suitable for geyser of capacity 25/50 litre including taking out the existing unserviceable one complete all as specified.
S & F in replacement of non return valve gunmetal for 15 mm bore with suitable fittings. Make - Kirloskar / Leader /Kartar .
S & F in replacement of PVC connection 15 mm dia 450 mm long with PTMT nuts on both sides for cold water connection.
S & F in replacement of PVC connection 15 mm dia 450 mm long with PTMT nuts on both sides for hot water connection.
S & F in replacement of PVC insulated and PVS sheathed flexible Copper Cable 3 core x 4.0 Sq mm from Geysers to socket.
S & F in replacement of plug top 3 pin 6 Amps 240 volts. Make : Anchor/Leader/Havells.
S & F in replacement of plug top 3 pin 16 Amps 240 volts. Make : Anchor/Leader/Havells.
Supply and fixing in rplacement of Weather proof flat twin core service cable size 16 Sq mm aluminium conductor PVC insulated and PVS sheathed.
Supply and fixing in rplacement of Weather proof flat twin core service cable size 10 Sq mm aluminium conductor PVC insulated and PVS sheathed.
S & F in replacement of apparatus plate (bottom plate in which element and thermostate are fixed) complete suitable for 25 ltr capacity geyser including taking out existing unserviceable one complete all as specified and directed.
Maintenace of solar water heater of capacity 200/300/500 Ltr Capacity and checking the FPC collector,tank insulation and flanges complete all defective parts to be replace and paid separately.
Supply and fixing in replacement of the following parts of solar water heater storage type of existing make and size complete all as specified and as directed by the Engineer-in Chargre :-
Aluminium dummy gascut
EPDM Hole gascut
Brass Flange
Threaded Flange
S & F in replacement of apparatus plate (bottom plate in which element and thermostat are fixed) complete suitable for 50 ltr capacity geyser including taking out existing unserviceable one complete all as specified and directed.
Repairing/overhauling of TPN/SPN DBs of any size/type fixed on building wall incl cleaning with compressed air, tightening of all electric connection to the bus bar & switch gears , refixing of loosed doors with proper fixing & locking arrangement & necessary welding work as required and replacement of wornout/ burnt/rusted/ loose lugs , door lock, nut bolt,hing, washers,internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire ,repair to plaster work as require at site and including disconnection of all cable/ sub main from the bus bar and insulating the neked portion of Al conductor and re-connect the same after repair of panel and proper connection of main earth wire/lead with panel body using lugs complete all as specified and directed.
S&F in replacement of Flame proof weather proof LED Tube light fitting CMRI certified recommended for gas/ vapor group IIA and IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass suitable for 2 x 16 Watt (4 feet) LED tube lights, including all accessories such as drivers, tub lights, connector etc complete all as specified.
M&L for porcelain vitreous white seperators and fixing screws etc to be refixing alongwith the pole and wall with existing copper strip complete all as directed by Engr in Charge.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried 6cm dept in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing including porcelain vitreous white seperators and fixing screws with brazing at each possible joint etc. as required 32X6mm GI strip complete all as directed by Engr in Charge.
Supply, mix and pouring the magnesium sulphate either through the existing watering pipe of by making holes surrounding the earth pit @ the rate of 05 Kg per pit for charging the earth pit for improving the ER values including measuring and recoding the value to achieve the result less than 01 Ohm.
S&F in replacement of switch Modular type single pole one way 6 Amps 240 volts complete all as specified and directed.
S&F in replacement of switch Modular type single pole one way 16 Amps 240 volts complete all as specified and directed.
S&F in replacement of bell push,modular type, 6 Amps ,240 Volts ISI marked complete.
S&F in replacement of socket 2 in 1, 3 pin 6 Amps, modular type, universal ,240 volts complete all as specified and directed
S&F in replacement of socket 2 in 1, 3 pin 16 Amps, modular type, universal ,240 volts complete all as specified and directed
S&F in replacement of stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz 2 module size in 5 steps modular type complete all as specified and directed.
DWARKA PERSHAD RADHEY RAMANLAL
Haasith constructions
Universal refrigeration and Engineering Company
Mavee Syndicate
MS ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .