Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.8 LAccepted-AOC 259 4TH CROSS HAL III STAGE BANGALORE 560075 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560075 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹48.5 L+₹3.5 L (7.69%)Rejected-Finance NO 237 7TH MAIN 3 D STAGE PILLANA GARDEN BANGALORE 560045 | BENGALURU URBAN | KARNATAKA | 560045 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹49.1 L+₹4.1 L (9.03%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹49.8 L+₹4.7 L (10.5%)Rejected-Finance 2 FLAT NO 2 B GEETHANJALI CLASSIK APARTMENT 9TH CROSS KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹49.8 L+₹4.8 L (10.6%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
18 Jun 2022, 6:00 pmClosed
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
EXTERNAL INTERNAL WALL FINISHES AT OTM ACCN OF ADMC 22 RAJ RIF PCTC AREA AND REPAIR REPLACEMENT OF INTERNAL WIRING ELECTRICAL FITTINGS FIXTURES AND OTHER CONNECTED WORKS IN R O OTM ACCN UNDER GE N BLR
2022_MES_528398_1
8297
Open Tender
Civil Works
Item Rate
180 days
BLR
Class D Category a(i) b(i)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹90,000
Yes
23 Jul 2022
3 Jun 2022
20 Jun 2022
3 Jun 2022
18 Jun 2022
13 Jun 2022
3 Jun 2022 - 11 Jun 2022
Amount
(B/R PORTION)
M&LPreparation of old surfaces including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts ,treating oil and greasy spots etc on wall surfaces and applying one coat of oil bound distemper white or tinted all as specified & as directed.
Ditto all as per item No-1.001 above but in two coats
M&L for Complete removal of existing treatment on wall and applying two coat of oil bound distemper white or tinted over a coat of alkali resistent primer complete all as specified and directed
M&L for Complete removal of existing treatment on wall and applying two coat of oil bound distemper white or tinted over a coat of alkali resistent primer over 1mm thick putty complete all as specified and directed
Ditto all as per item No 1.001 above but on ceiling surfaces
Ditto all as per item No 1.003 above but on ceiling surfaces
M&L Preparation of old surfaces including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts ,treating oil and greasy spots etc and applying one coat of white wash on internal wall surfaces all as specified & as directed.
Ditto all as per item No 1.007 above but in two coats
Ditto all as per item No 1.007 above but in ceiling surfaces
M&L Preparation of old surfaces including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts ,treating oil and greasy spots etc on wall and applying one coat of cement base paint complete all as specified and directed.(Buildings upto four storey high)
M&L Preparation of old surfaces including brooming down with steel wire brushing scrapping down soot’s, moulds, moss and efflorescence, salts ,treating oil and greasy spots etc on wall and applying two coat of cement base paint all as specified and directed.(Building upto four storey high)
M&L Complete removal of existing treatment on wall surface of any description including brooming down with steel wire brushing scrapping down smoke soot's ,moulds,moss and efflorescence,salts ,trading oil and greasy spots etc and Applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm including filling the cracks etc with crack filling material as per manufacturers instructions complete all as specified and as directed. Note :- Work is being carried out in High rise Building, height exc 15.00 RM N.exc 25.00RM. Necessary safety precautions/Insurance etc of workers to be taken care of by the contractor as per Govt Norms/Labour Acts
M&L Complete removal of existing treatment on wall surface of any description including brooming down with steel wire brushing scrapping down smoke soot's ,moulds,moss and efflorescence,salts ,trading oil and greasy spots etc and Applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives @ 1.43 litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm including filling the cracks etc with crack filling material as per manufacturers instructions complete all as specified and as directed. (Buildings upto four storey high)
M & L for preparation of old painted wooden surfaces of any description exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M & L for preparation of old painted steel surfaces of any description exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for writing letters or figures (Block, Roman, Italic or Indian) n.exc 30cm high
M&L for writing stops, commas, short lines, dashes, hyphens, brackets, etc
M & L 4-5 mm tinted/coloured glass glazing with oil putty in squares n.exc 1.5 Sqm in each pane all as specified and as directed. incl Hacking out old broken glass of any thickness, size, quality or description from metal frame/Alu Sliding/fixed window including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed.
M&L for 4mm thick Sheet glass, ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm in each pane all as specified and as directed. incl Hacking out old broken glass of any thickness, size, quality or description from metal frame including punching or drilling out old glazing pins/spring clips etc complete all as specified and as directed.
Taking down cement plaster of any description hacking for key or raking out joint on old brick work/stone/concrete sfurface
M&L for rendering 15 mm thick on fairfaces of brick work or concrete surfaces in cement mortar 1:6 finished plastered surface even and smooth without using extra cement
M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 with WPC, finished plastered surface even and smooth without using extra cement Note :- WPC will be measured and paid separately
Supply only liquid water proofing compound
M&L for rendering 5 mm thick on ceiling /RCC surfaces in cement mortar 1:3, finished plastered surface even and smooth without using extra cement
M&L Preparation of newly plastered surfaces and applying two coat of oil bound distemper over a coat of alkali resistent primer complete all as specified and directed
M & L preparation of newly plastered surface of wall and applying two coats of cement base paint complete all as specified and as directed.
M & L for preparing newly plastered ceiling surfaces and applying three coat of white wash complete all as specified & as directed.
Material and labour for spraying antiweed / non toxic solution / chemicals containing Glyphosate as per manufacture instructions and removing the weed including the roots after ensuring complete de-germification of palnt/weed and cutting down the plant/trees off from roof/top sides of external walls of bldgs, in chajjas, wall junctions, junctions of GI/CI/AC/PVC pipes and taking out roots entered in wall/slabs, including making good the surface using PCC 1:2:4 type B1 or cement mortar (1:2) or brick work in CM(1:4) plastered with CM(1:4) to match with existing surface and repairing the pipes and joints which was affected by cutting down/taking out process all as specified and as directed for plants / trees located in the buildings upto four storey high, complete all as specified and directed by Engineer-in-charge. NOTE:- Contractor has to execute the work of de-generated plant/weeds as per the prior approval and directions of Engineer-in-charge.
(E/M PORTION)
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, call bell socket or power circuits), without taking out switches, sockets, regulators, light fittings, etc., complete and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Concealed Point Wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concealed in walls incl MS terminal boxes fabricated with 1.6 mm thick MS sheet, covering with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for One light point controlled by one switch / One fan point controlled by one switch/regulator / one bell/buzzer point controlled by bell push
All as per Serial Item No 2.002 here-in-above, but for one light point controlled by two way swtich
All as per Serial Item No 2.002 here-in-above, but for one 3 pin socket outlet 5 Amps on indepenedent board.
All as per Serial Item No 2.002 here-in-above, but for one 3 pin socket outlet 5 Amps on Same Board.
Material and labour for Concealed Point Wiring (For modular type switch & sockets) complete with 1.5 Sq mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiring incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for One light point controlled by one switch / One fan point controlled by one switch/regulator / one bell/buzzer point controlled by bell push
All as per Serial Item No 2.006 here-in-above, but for one light point controlled by 2 way swtich
All as per Serial Item No 2.006 here-in-above, but for one 3 pin socket outlet 5 Amps on indepenedent board.
All as per Serial Item No 2.006 here-in-above, but for one 3 pin socket outlet 5 Amps on Same Board.
Material and labour for Point Wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC Casing & Caping ISI marked incl accessories surface type wiring incl 1.6 mm thick MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for One light point controlled by one switch / One fan point controlled by one switch/regulator / one bell/buzzer point controlled by bell push
All as per Serial Item No 2.010 here-in-above, but for one light point controlled by 2 way swtich
All as per Serial Item No 2.010 here-in-above, but for one 3 pin socket outlet 5 Amps on indepenedent board.
All as per Serial Item No 2.010 here-in-above, but for socket outlet 5 Amps on Same Board.
All as per Serial Item No 2.002 here-in-above, but for concealed wiring drawn through including Conduit, but with 2.5 Sq mm cable and earth continuity conductor of 2.5 Sq mm
All as per Serial Item No 2.014 here-in-above, but with 2.5 Sq mm cable and earth continuity conductor of 2.5 Sq mm Notes for Serial Item Nos 2.002 to 2.015 :- (i) The earth wire for points in the same circuit can be looped from point to point, (ii) Earth wire shall be taken inside the conduit, (iii) Cost of terminal box shall deemed to be included in the item rate quoted for point wiring, (iv) Cost of cable from DB to any switch/ socket board to be included in point wiring. (v) Cutting chases, grooving, etc., required for taking down / providing concealed wiring will be measured and paid for separtely under respective item.
Taking down unserviceable sub main wiring, supply and fixing Sub main wiring using FRLS grade PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable, 2 runs of single core of size 4 Sq mm and one run of earth continuity conductor of size 4 Sq mm to be drawn through and including PVC non metallic rigid conduit complete all as specified and as directed. NOTE: - Two runs of 4 sq.mm cable, one run of 4 sq mm earth wire and PVC conduite shall be measured as one length.
Taking down unserviceable sub main wiring, supply and fixing Sub main wiring using FRLS grade PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable, 2 runs of single core of size 6 Sq mm and one run of earth continuity conductor of size 6 Sq mm to be drawn through and includin PVC non metallic rigid conduit complete all as specified and as directed. NOTE: - Two runs of 6 sq.mm cable, one run of 6 sq mm earth wire and PVC conduite shall be measured as one length.
Taking down unserviceable sub main wiring, supply and fixing Sub main wiring using FRLS grade PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable, 2 runs of single core of size 2.5 Sq mm and one run of earth continuity conductor of size 2.5 Sq mm to be drawn through and includin PVC non metallic rigid conduit complete all as specified and as directed. NOTE: - Two runs of 2.5 sq.mm cable, one run of 2.5 sq mm earth wire and PVC conduite shall be measured as one length.
Supply and fix in repairs, Modular Switch, One module, One way, 6 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular Switch, One module, One way, 16 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular Switch, One module, bell push, 6 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular Switch, One module, two way, 6 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular socket, 6 Amps, 5 pin combined, 2 module, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular socket outlet, 2 Module, 6 pin, 6/16 Amps (multi purpose), complete all as specified and directed.
Supply and fix in repairs, Modular fan Regulator,120 W, electronic stepped type, 230 Volts 2 module, complete all as specified and as directed.
Supply and fix in repairs, piano Switch, flush type, One way, SP, 5 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, piano Switch, flush type, two way, SP, 5 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, flush type, bell push, SP, 5/6 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, switch socket combination 5 pin, 2 in 1, 5 Amps, flush type, 240 Volts all as specified and as directed.
Supply and fix in repairs, switch socket combination 3 pin, 2 in 1, 5 & 15 Amps, flush type, 240 Volts all as specified and as directed.
Supply and fix in repairs, flush type socket outlet, 2 in 1, 3 pin 5 Amps, 240 V, complete all as specified and directed.
Supply and fix in repairs, lamp holder, pin type, pvc/polycarbonate made, complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repairs, fan Regulator, 120 W, electronic stepped type, 230 Volts, complete all as specified and as directed.
Supply and fix in repairs, Ding Dong bell, SP, AC, 230 Volts, complete all as specified and as directed.
Supply and fix in repairs, Ceiling rose surface type, Bakelite, 65 x 50 mm ISI marked with three terminals all as specified and as directed.
Supply and fix in repairs, MCB SP, 240 volts, 6 to 32 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Supply and fix in repairs, MCB TPN, 415 volts, 31 to 63 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Taking down unserviceable sheet metal enclosure/ DB, supply and fix, MCB DB SPN 4 way (Horizontal), double door with Sheet metal enclosure, flush mounted, prewired, 240 V, AC, 50 Hz, Factory made, powder coated, IP-42 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCB/ Isolators will be measured and paid separately as supply and fix under respective items.
All as per Serial Item No 2.040 here-in-above, but SPN 8 ways
All as per Serial Item No 2.040 here-in-above, but TPN 4 ways, 415 V
Supply and fixing in repirs, wall mounted LED batten, energy efficient, 20 Watt, 4 feet, with high lumen output of 2000 lumens and diffuser should be High translucent serrated milky white, environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > =100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH <20%, power factor ≥ 0.90, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80 & integrated electronic driver 20 W fitting prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable complete in all respects all a directed by Engineer-in-charge. Cat Part No 830192 18W CDL of Bajaj or techno commercially equivalent makes specified here-in-after complete all as specified.
All as per Serial Item No 2.043 here-in-above, but of 9/10 W LED tube light fitting 2 feet long and polycarbonate housing. Cat Part No 830206 10W CDL of Bajaj or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply and fix in repairs, bulkhead LED luminaries 10W energy efficient solution for upgrading convertional light fittings, with IP 65 protection, Make: Bajaj, Cat No : BIBWP 10W LED or or techno commercially equivalent makes specified here-in-after complete all as specified.
Supply and fix in repairs, Slim surface mounted round LED down lighter 12W die cast body with premium diffuser to ensure glare free and even distribution of light, Make: Bajaj, Cat No : BGSLO SLEEK SURFACE 12 W WH RD LED or techno commercially equivalent makes specified here-in-after complete all as specified.
Taking down existing security light fitting, Supply and fix 30 W, LED security light fittings with lamp 30 W with high lumen output, environmental friendly, energy efficient LED, with pressure die cast housing with toughened glass and high power LEDs with secondary optics, with lamps and accessories, IP 66 protection, system electrical efficiency > 85%, system efficacy > 110 IP/W, 10 KV SPD, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, integral drivers, connecting to loop boxes electrically, light fitting conforming to Cat No ENXT P 30L WH SY PC SC of Bajaj or techno commercially equivalent approved model complete with all accessories and lamp complete all specified and as directed.
Taking down existing brackets, providing Material and labour, for bracket made of Galvanized iron pipe 25 mm dia, light grade, bend to shape not less than 1.2 mtr with 2 Nos of MS clamps fabricated out of MS Flats of size 25 x 6 mm, bolts , nuts of suitable size for fixing street light fittings, including 2 coats of aluminium paint complete all as specified and as directed.
Supply and fix in repairs, sheet metal enclosure, SPN, with metal plug and socket, 20 Amps, 240 Volts, complete all as specified and as directed.
S&F 2' x 2' Recess mounted LED Luminaire suitable for Gypsum/ grid type false ceiling of capacity 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZRSQL 36W GZI WH / LTCRSLM36WATT2X2 of C & S / HLFPR22-36-CW-R of Halonix
S&F 2 x 2 Recess mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZRSQL 36L GX D WH SD od BAJAJ / LTCRSLM36WATT2X2 of C & S / HLFPR22-36-CW-R of Halonix
S&F 2 x 2 Recess mounted mounted round LED pane fitting of 12 watt al. die cast body with premium diffuser to ensure glare free & even distribution of light.Make & Model No:BPSLR 12W WH of Bajaj or equivallant inHavells / C & C
Demolishing of existing earth pits, and providing Material and labour for, earthing complete with Galvanized Iron earth plate electrode 600 mm x 600 mm x 6 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized earth lead wire of 4 mm dia by means of bolts, nuts, Contd/... 2.052
Condt/...2.051 check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery / equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 40 mm bore light grade GI pipe for watering funnel wire mesh, PCC chamber in CC (1:3:6), type C1, manhole cover with RCC (1:2:4), type B1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover and MS frame etc., complete all as specified and as directed NOTE :- Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Cutting chases, pinning in, where required for concealed conduit wiring, and making good disturbed surfaces to match with adjacent surfaces including pointing in cement mortar 1:3, girth not exceeding 15 cm on brick / PCC block masonry / concrete surfaces, complete all as specified and as directed.
RK Builders
Atom Engineers and Builders
Sreyas Enterprises
J PUSHPALATHA ENGINEER AND CONTRACTOR
MAA ENGINEERING SERVICERS
PRACHANIVA CONSTRUCTIONS
Janatha Trading Corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .