| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70 LAccepted-AOC C 109 POCKET C SECTOR 2 DSIIDC INDUSTRIAL AREA BAWANA DELHI DELHI 110039 UDYAM DL 06 0004527 | NORTH DELHI | DELHI | 110039 | ₹70 L | L1 | Accepted-AOC L1 |
| 2 | L2₹70.7 LRejected-Finance | ₹70.7 L | L2 | Rejected-Finance L2 |
| 3 | Rejected-Technical 108 AND 111 COMMERCIAL ROAD 133001 | AMBALA | HARYANA | 133001 | - | - | Rejected-Technical Power of attroney not attached |
| Sl No | Description | Qty | Unit | AAR KEY INDUSTRIES L1 | H S Enterprises L2 |
|---|---|---|---|---|---|
| 1.01 | 1) Supply, Installation, Testing and Commissioning of High frequency IGBT based Emergency Rescue Device having following specifications.
AC Input - 340-460 Volts AC Three PhaseDC Input - 360 Volts DC AC Output - 400 Volts AC Three Phase ,Sine wave
Stability - ±1% Cooling - Forced Air Cooled Frequency - 50 Hz plus -0.5Hz
Total harmonic Distortion - less than 2% on linear load
Overall efficiency - more than 90% Power Factor - 0.8
Manual By Pass - Provided
Input/ Output termination - Provided
Switching Frequency - 10 Khz
KW Rating - Shall be 0.7 times the KVA Rating
IP Rating - IP 20
Overload - The system shall withstand 10% Overload for One minute.
Protection - Over voltage, short circuit and overload at output Terminal,Low battery and high battery Cut off
Indicators - Mains, battery charging,UPS ON,Output Overload, Battery Low and UPS Trip.
Digital Meter shall be provided for:- Input AC Voltage, Output AC Voltage,Current and Frequency, Battery Voltage and charging Current.
Isolation Transformer - Built in Isolation Transformer at invertor output shall be provided.
AC Input MCCB - A suitable rating TP MCCB shall be provided at the
- Mains Input.
DC Circuit Breaker - Suitable rating DC MCCB shall be provided at the Battery Input.
Regenerative Power - ERD shall be equipped to handle Regenerative Power of the lift motor.
The entire assembly shall be housed in a sheet steel enclosure duly powder coated
and mounted on unidirectional castor wheels for easy movement of the Equipment.
Capacity :- 30 KVA
Make : (IECO/Aar Key/Hi-Shine/ABB)
Lead Acid SMF VRLA Battery Bank consisting of 12V,42 AH,30 Nos. Batteries
( Make- EXIDE/Quanta)
Matching cabinet/open rack to house 30 Nos12V,42AH SMF Batteries complete
With battery interlinks for 30KVA ERD.
MCCB 125 Amps Four Pole with enclosure(2Nos) 16 Sq mm ,4 Core Copper wire (Not exceeding 20 Meters) | 8 | Each | 8,75,000 ₹70 L | 8,84,000 ₹70.7 L |
Tender Value
₹64.0 L
EMD Value
₹1.3 L
Closing Date
9 Jan 2026, 5:00 pmClosed
RAVI Ladwal
ED - Rewari
Construction of Govt. Medical College at village Koriyawas, Distt. Mohindergarh (Pdg. Emergency Rescue Device for lifts of Type 2,3,4 and 5 Residences)
2026_HRY_494590_1
20267EE4891D C7CB 4527 8ACF 88FE3ABDBCB7668BAR
Open Tender
Civil Works
90 days
KORIAWAS
2 documents required · 2 mandatory
₹5,000
₹1.3 L
Yes
31 Mar 2026
2 Jan 2026
12 Jan 2026
2 Jan 2026
9 Jan 2026
2 Jan 2026
1) Supply, Installation, Testing and Commissioning of High frequency IGBT based Emergency Rescue Device having following specifications. AC Input - 340-460 Volts AC Three PhaseDC Input - 360 Volts DC AC Output - 400 Volts AC Three Phase ,Sine wave Stability - ±1% Cooling - Forced Air Cooled Frequency - 50 Hz plus -0.5Hz Total harmonic Distortion - less than 2% on linear load Overall efficiency - more than 90% Power Factor - 0.8 Manual By Pass - Provided Input/ Output termination - Provided Switching Frequency - 10 Khz KW Rating - Shall be 0.7 times the KVA Rating IP Rating - IP 20 Overload - The system shall withstand 10% Overload for One minute. Protection - Over voltage, short circuit and overload at output Terminal,Low battery and high battery Cut off Indicators - Mains, battery charging,UPS ON,Output Overload, Battery Low and UPS Trip. Digital Meter shall be provided for:- Input AC Voltage, Output AC Voltage,Current and Frequency, Battery Voltage and charging Current. Isolation Transformer - Built in Isolation Transformer at invertor output shall be provided. AC Input MCCB - A suitable rating TP MCCB shall be provided at the - Mains Input. DC Circuit Breaker - Suitable rating DC MCCB shall be provided at the Battery Input. Regenerative Power - ERD shall be equipped to handle Regenerative Power of the lift motor. The entire assembly shall be housed in a sheet steel enclosure duly powder coated and mounted on unidirectional castor wheels for easy movement of the Equipment. Capacity :- 30 KVA Make : (IECO/Aar Key/Hi-Shine/ABB) Lead Acid SMF VRLA Battery Bank consisting of 12V,42 AH,30 Nos. Batteries ( Make- EXIDE/Quanta) Matching cabinet/open rack to house 30 Nos12V,42AH SMF Batteries complete With battery interlinks for 30KVA ERD. MCCB 125 Amps Four Pole with enclosure(2Nos) 16 Sq mm ,4 Core Copper wire (Not exceeding 20 Meters)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.00 MB
BOQ_573050.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid