| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 CrAccepted-AOC | ₹12.5 Cr | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹12.9 CrRejected-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA UDYAM DL 06 0048538 | NORTH WEST DELHI | DELHI | 110035 | ₹12.9 Cr | L2 | Rejected-Finance Not being L1 Bidder |
| 3 | L3₹14.6 CrRejected-Finance JODHPUR ROAD UTARLAI BARMER RAJ 344035 | BARMER | RAJASTHAN | 344035 | ₹14.6 Cr | L3 | Rejected-Finance Not being L1 Bidder |
| 4 | L4₹16.3 CrRejected-Finance | ₹16.3 Cr | L4 | Rejected-Finance Not being L1 Bidder |
| 5 | L5₹16.3 CrRejected-Finance 3A RAM MOHAN MULICK GARDEN LANE UNIT NO 6A 3RD FLOOR KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | ₹16.3 Cr | L5 | Rejected-Finance Not being L1 Bidder |
Tender Value
₹14 Cr
EMD Value
₹10.3 L
Closing Date
4 Nov 2024, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
CONSTRUCTION OF ATC TOWER ALONG WITH ALLIED SERVICES AT AF STN KALAIKUNDA UNDER GE (P) (AF) KALAIKUNDA.
2024_MES_666905_2
88860/KKD/E8
Open Tender
Civil Works
700 days
GE (P) (AF) KALAIKUNDA
As per NIT Conditions
8 documents required · 8 mandatory
₹3,000
GE (P) (AF) KALAIKUNDA
₹10.3 L
Yes
4 Dec 2024
6 Sept 2024
11 Nov 2024
6 Sept 2024
4 Nov 2024
21 Oct 2024
Amount
NOTE (Applicable for all parts/items):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
SCHEDULE "A" Part - I (BUILDING / STRUCTURES WORK ) Details of pre priced schedule is given in tender documents
SCHEDULE "A" PART-II (SITE CLEARANCE, EARTH WORK AND EXCAVATION ) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/PATH/CULVERT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-X (LIGHTENING PROTECTION) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART-XI (VERTICAL CABLE DUCT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (SIGNAL SQUARE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (RCC CABLE DUCT) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIV (RAIN WATER HARVESTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XV (FIRE HYDRANT AND FIRE ALARM SYSTEM) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XVI (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' 5 ' signifies this fact only.
Supply only Non-circular synthetic fibre, @0.25% by weight of cement complete all as specified and directed.
M & L Soakage wells for 50 Users, excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified and as directed.
Construction of brick masonry valve pit of internal dimension 120 cm x 120 cm x 90 cm depth with fly ash bricks in CM (1:4) and 10 mm thick plastering in CM (1:4) internally and externally upto 15 cm below GL, 100 mm thick PCC (1:4:8) type D2 (using 40 mm graded broken stone aggregate) as in foundation lean concrete, PCC (1:3:6) type C1 (using 20 mm graded broken stone aggregate) as in bedding and copping, MS frame with 40x40x6 mm angle iron all around fixed by means of 04 Nos holdfast 150 mm long made out of 40x6mm embedded in PCC block 1:2:4 type B-1 (using 20 mm graded aggregate) of size 250 x 200 x 150 mm, 3 mm thick MS sheet cover plate with locking arrangements including 65 mm dia Godrej pad lock, hinges and two coats of synthetic enamel paint over one coat of red oxide primer including preparation of surface, three coats of white wash on plastered surface (exposed to view) including necessary excavation in soft/loose, soil, returning filling in and removal of surplus soil to a distance not exceeding 50 m complete all as specified and directed.
Supply and install testing and commissioning of monoblock pumping Set suitable for 230V, Single phase , 20 mtr head of capacity 1 HP including all connections duly mounted on MS frame on foundation / platform grouted with MS bolts, nuts of required size properly connected with suction and delivery water line, complete all as specified and as directed.
M & L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all directed.
Supply, installation, testing and commissioning of 11 KV of rating 630 Amps RMU unit Indoor extensible type (IP-54) protection duly painted ,SF-6 gas insulated RMU (Ring main unit) Three way comprising of one number SF6 Circuit Breaker as incoming and Two numbers SF6 Circuit Breaker as outgoing inside SF6 gas filled stainless steel (nonferrous and nonmagnetic grade) tank having IP-67 degree of protection with painting as per manufacturer specification and leak rate of SF-6 gas less than 0.1% , gas refillable at site/factory. RMU shall be provided with Copper Bus bar, one number fault passage indicator, mechanism for interlocking arrangements including powered relay (IDMT) complete with all accessories as under RMU type installation Indoor type, arc proof as per IEC: 62271-200 for design, Manufacturing and testing. The RMU shall have the following features/specifications :- (i) Rated Voltage upto -12 KV (ii) Rated power frequency withstand voltage -28KV. (iii) Rated lightning impulse withstand voltage -shall be minimum 75 KVP. (iv) Rated current for ring main feeder -630A.
Item No 16.07 ..... Contd (v) Rated current for VCB feeder- 630A. (vi) Rated short-time current-21 KA/3 Sec. (vii) Rated short making current -52.5 KA. (viii) Ambient temperature- (-1 degree Celsius to +50 degree Celsius), (ix) Degree of protection against accidental contact and ingress of foreign objects shall be assured as under :- (aa) Main electric circuits : IP-67, (ab) Fuse compartment IP3X, (ac) Operating mechanism -IPXC, (ad) Cable connection compartment -IP2XC with site replaceable cable busing. (x) Each Incoming/Outgoing circuit Breaker includes :- (aa) Manual circuit breaker with position ON-OFF manual spring charging mechanism with in- built spring charging handle mechanically latched ON/OFF push buttons. (ab) Manual line disconnector with three position switches ON-OFF-EARTH (ac) Auxiliary switches 6 NO + 6NC with wiring (ad) Numerical relay for Over current and earth fault protection including power pack of suitable capacity with minimum 120 minute backup time (ae) Capacitive Voltage indicator (af) Padlocking facility (ag) Dedicated CTs of ratio 100-50/1-1A (double core including switching contacts) for protection (ah) Mimic diagram at the front facia of RMU (aj) Digital 3 Phase Multifunctional meter
Item No 16.07 and 16.08 Contd ..... (ad) Numerical relay for Over current and earth fault protection including power pack of suitable capacity with minimum 120 minute backup time (ae) Capacitive Voltage indicator (af) Padlocking facility (ag) Dedicated CTs of ratio 100-50/1-1A (double core including switching contacts) for protection (ah) Mimic diagram at the front facia of RMU (aj) Digital 3 Phase Multifunctional meter
Item No 16.07 , 16.08 and 16.09 Contd ..... (xi) 11 KV Indoor type resin cast Potential transformer of ratio 11 KV/rt3/110 V/rt3, Class 1, Burden 50 VA for incoming SF6 Breaker – 01 Set (xii) Operating handle - 1 number, (xiii) Right angled Cable boots - 3x sets, (xiv) Capacitor for voltage indicators (xv) Any Other standard accessories required for efficient operation of RMU as per OEM recommendations. (Note: This item rate includes rates for foundation as per OEM recommendation)
Supply and installation, testing and commissioning indoor type 180 KVAR capacity APFC bank panel, MDXL offered Heavy duty Mixed dielectric type Box capacitor with 7 % Aluminum wound Reactor, units tested in accordance with IS 13340-1993/IS 13341-1992, IEC 60831 part 1 & 2 with thyristor control module with aluminium heat sink with semi-conductor fuses, smooth switching ON and OFF automatically at +/- 10 Volts, compartmental design dust and vermin proof suitable for 3 phase, 4 wire 440 volt, made out of 2mm thick CRCA sheet with built upon rigid frame work, cubical type, heavy duty powder coated RAL 7035 capacity 180 KVAR (2x50, 20x3+10x1+5x2) KVAR capacitor bank having following accessories including control wiring with HR FR/FRLS copper wire complete all as specified and as follows :- (i) To withstand on Non Liner load upto 40% (ii) 2.5 in Over Current with stand. (iii) 10000/year Switching capacity. (iv) 1,60,000 hours life expectancy. (v) Capacitor, MCB/MCCB, Contractors, APFC Relay shall be of same make. (vi) Panel fabrication shall be in-house and at component manufactures own factory. (vii) APFC design with Aluminium bus bar as per global standard current density of 0.8A/Sqmm, (1A/Sq mm in case of copper) (viii) Ambient shall be of 45*C (ix) Ventilation air within cubicle must flow upwards. (x) Extractor fan shall be fitted on top of cubicle. (xi) Bottom air intel shall be as low as possible. (xii) Cross section of top air outlet shall be more than bottom outlet. (xiii) Reactor shall be fitted in separate enclusure of capacitor. (xiv) APFC relay with RS485 communication, Dual setting for EB & DG load , to monitor KVAR de rating, inbuilt programmable alarm for capacitor dating, Harmonic Monitoring 3rd to 19th, Temperature alarm and with Fan control relay. (xv) Compact modular bolted design, removable side and back panels with bottom cable entry.
Supply & Fixing Servo controlled voltage stabilizer (bearing BIS: 9815: Part 1: 1994 reaffirmed 2009) of capacity 630 KVA 3-phase, 50Hz, Naturally Oil Cooled, Indoor/Outdoor, Unbalanced Type, Copper Wound, Digital Display Type, Relay Free Smooth and Silent Operation with 1st filling of Transformer oil (IS335: 1993 re-affirmed 2005) having following specification: (i) Input voltage 300V-480V or as per ground requirements (ii) Output voltage stabilized at any designed/desired voltage 415V ± 1% (Adjustable) (iii) Rated frequency 50 Hz (iv) No distortion in wave form (v) Response time not to exceed 10 mille seconds (vi) Sensitivity (±)1% (vii) Rate of correction 8 Volt/second for single phase and 20 Volt/second for phase to phase (viii) No load losses less than 0.5% (ix) Full load losses less than 2.5% (x) Duty cycle - continuous 24 x 7 (xi) Efficiency more than 95% (xii) Type of load: 3 phase, unbalanced type (xiii) Digital display Voltmeter/Ampmeter With following protections :- (i)Over load/Short circuit protections (ii). High/Low voltage cut off (iii) By pass arrangement in case of emergency (iv) Single phase sequence change protection NOTE- ( i) Pre-dispatch inspection at OEM factory premises shall be carried out by Rep of Accepting officer. (ii) Acceptance test: The testing of Servo voltage stabilizer shall be carried out in accordance with para 11.2 of the BS 9815 (Part-1 ) ( Reaffirmed 2004) The following shall be carried out by SEI /EI at the site after installation of stabilizer . (i) Physical Examination (ii) Insulation resistance (iii) High voltage test (iv) Leakage current test (v) Provision of earthing (vi) Output Voltage (vii) No load Current (viii) Measurement of no load losses (ix) Induced voltage test etc.
Taking out HT/LT cable of any size and rerouting the same by using unbreakable bricks and new and fresh sand at new location as per site requirement all as specified and directed. Note : Excavation and earth work shall be measured separately.
Supply,install,testing & commissioning of factory made indoor cubical type LT feeder piller Box of 2.5 x 1.5 x 0.9m size totally enclosed weather ,dust vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and 2.0mm thick CRCA (cold rolled cold annealed ) MS sheet bend to shape ,front & back side operated double door with proper hinge and locking arrangement and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete including internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley . 1500Amp size of Bus bar shall be insulated with colour code/sleeves /tapes sincluding necessary PCC (1:3:6) type C2 for foundation /Platform above ground level all as specified and directed .LT panel board shall be complied in all respects with and including the following accessories:- (a) Incoming (i) ACB with microprocessor Rlease 1000 Amps, 4 Pole, 415 V, 50 kA MOD Type (ii) Panel mounted digital multifunctional meter in 96X96 Sqmm flush mounted case SP, accuracy class 1.0,0.5, voltage measuring rane 50-520VAC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A, F, PF, kW, kVA, kWh/kVAh. (iii) Indicator Lamp - R - Y - B (Set of three)- 01 No (b) Outgoing (i) ACB with microprocessor Rlease 800 Amps, 3 Pole, 415 V, 50 kA - 01 No (iii) MCCB 125 Amps, 3 Pole, 415 V, 25 kA -02 No ( 1W + 1 Spare) (iii) MCCB 80 Amps, 3 Pole, 415 V, 25 kA-03 No (01 For Lift & 01 for Substation & DG Shed)
Supply,install,testing & commissioning of factory made indoor cubical type LT feeder piller Box of 2.5 x 1.5 x 0.9m size totally enclosed weather ,dust vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and 2.0mm thick CRCA (cold rolled cold annealed ) MS sheet bend to shape ,front & back side operated double door with proper hinge and locking arrangement and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete including internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley . 1200 Amp size of Bus bar shall be insulated with colour code/sleeves /tapes sincluding necessary PCC (1:3:6) type C2 for foundation /Platform above ground level all as specified and directed. LT panel board for Main ATC Bldg shall be complied in all respects with and including the following accessories:- (a) Incoming (i) ACB with microprocessor Rlease 800 Amps, 4 Pole, 415 V, 50 kA MOD Type (ii) Panel mounted digital multifunctional meter in 96X96 Sqmm flush mounted case SP, accuracy class 1.0,0.5, voltage measuring rane 50-520VAC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A, F, PF, kW, kVA, kWh/kVAh. (iii) Indicator Lamp - R - Y - B (Set of three)- 01 No (b) Outgoing (i) MCCB 250 Amps, 3 Pole, 415 V, 36 kA - 03 Nos (iii) MCCB 200 Amps, 3 Pole, 415 V, 36 kA -01 No (iii) MCCB 125 Amps, 3 Pole, 415 V, 25 kA -02 Nos
Supply,install,testing & commissioning of factory made indoor cubical type LT feeder piller Box of 1.5 x 1.2 x 0.9m size totally enclosed weather ,dust vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and 2.0mm thick CRCA (cold rolled cold annealed ) MS sheet bend to shape ,front & back side operated double door with proper hinge and locking arrangement and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete including internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley . 400 Amp size of Bus bar shall be insulated with colour code/sleeves /tapes sincluding necessary PCC (1:3:6) type C2 for foundation /Platform above ground level all as specified and directed. LT panel for First Floor shall be complied in all respects with and including the following accessories:- (a) Incoming (i) MCCB 250 Amp 4 Pole, 415 Volt with thermal magnetic 36 kA. - 01 Nos (ii) Panel mounted digital multifunctional meter in 96X96 Sqmm flush mounted case SP, accuracy class 1.0,0.5, voltage measuring rane 50-520VAC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A, F, PF, kW, kVA, kWh/kVAh. (iii) Indicator Lamp - R - Y - B (Set of three)- 01 No (b) Outgoing (i) MCCB 100 Amps, 3 Pole, 415 V, 25 kA - 01 No (iii) MCCB 63 Amps, 3 Pole, 415 V, 10 kA -01 No (iii) MCCB 40 Amps, 3 Pole, 415 V, 10 kA -02 Nos
Supply,install,testing & commissioning of factory made indoor cubical type LT feeder piller Box of 1.5 x 1.2 x 0.9m size totally enclosed weather ,dust vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and 2.0mm thick CRCA (cold rolled cold annealed ) MS sheet bend to shape ,front & back side operated double door with proper hinge and locking arrangement and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete including internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley . 300 Amp size of Bus bar shall be insulated with colour code/sleeves /tapes sincluding necessary PCC (1:3:6) type C2 for foundation /Platform above ground level all as specified and directed. LT panel for Second Floor shall be complied in all respects with and including the following accessories:- (a) Incoming (i) MCCB 200 Amp 4 Pole, 415 Volt with thermal magnetic 36 kA. - 01 No (ii) Panel mounted digital multifunctional meter in 96X96 Sqmm flush mounted case SP, accuracy class 1.0,0.5, voltage measuring rane 50-520VAC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A, F, PF, kW, kVA, kWh/kVAh. (iii) Indicator Lamp - R - Y - B (Set of three)- 01 No (b) Outgoing (i) MCCB 100 Amps, 3 Pole, 415 V, 25 kA - 01 No (iii) MCCB 63 Amps, 3 Pole, 415 V, 10 kA -01 No (iii) MCCB 40 Amps, 3 Pole, 415 V, 10 kA -02 Nos
Supply,install,testing & commissioning of factory made indoor cubical type LT feeder piller Box of 1.5 x 1.2 x 0.9m size totally enclosed weather ,dust vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and 2.0mm thick CRCA (cold rolled cold annealed ) MS sheet bend to shape ,front & back side operated double door with proper hinge and locking arrangement and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete including internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley . 400 Amp size of Bus bar shall be insulated with colour code/sleeves /tapes sincluding necessary PCC (1:3:6) type C2 for foundation /Platform above ground level all as specified and directed. LT panel for Third Floor shall be complied in all respects with and including the following accessories:- (a) Incoming (i) MCCB 250 Amp 4 Pole, 415 Volt with thermal magnetic 36 kA. - 01 No (ii) Panel mounted digital multifunctional meter in 96X96 Sqmm flush mounted case SP, accuracy class 1.0,0.5, voltage measuring rane 50-520VAC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A, F, PF, kW, kVA, kWh/kVAh. (iii) Indicator Lamp - R - Y - B (Set of three)- 01 No (b) Outgoing (i) MCCB 100 Amps, 3 Pole, 415 V, 25 kA - 02 No (iii) MCCB 63 Amps, 3 Pole, 415 V, 10 kA -01 No (iii) MCCB 40 Amps, 3 Pole, 415 V, 10 kA -02 Nos
S & F for cable route/joint indicator made of RCC slab of size 90 cm x 30 cm x 10 cm embedded in ground on the route of cable duly marked with HT cable / HT cable joint complete all as specified and as directed.
S&F isolation transformer single phase 230 Volts 50 Hz of capacity 2 KVA all as specified and directed.
S & F surge protection device IEC class I/EN type 1 & 2 surge suppresser as per IEC for MDP three phase complete all as specified and directed..
S & F ceiling mounted dimmer controlled spot lighting assembly with 18 watts LED type all as specified and directed.
S & F UPS for 30 min back up single phase AC input 160 to 260 V and output 230V ±1% of capacity 1 KVA complete all as specified and directed.
S & F rubber mat 2m x 1m, 19 mm thick forsubstation complete all as specified and as directed.
S & F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including street light GI pipe bracket of medium grade 40mm dia. ,1.5m long bend to required size and shape including two coat of aluminum paint over a coat of red oxide primer complete in all respect all as specified and directed.
S&F PVC insulated unsheathed multistranded copper conductor 2.5 Sqmm 1100 V grade twin core for street light connection from fitting to junction box all as specified and directed.
S & F MCB SP, 230 volts, 63 Amps, 10 kA rupturing capacity ‘C’ series complete all as specified and directed.
S & F LED step light 3 watt in powder coated die cast aluminium housing in IP 65 protection complete all as specified and directed.
S&F LED light fittings 4 feet, 1 x 20 W, 220 V AC decorative box type with driver including LED tube light, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED light fittings with high output diffuser 2 feet, 1 x 10 W, 220 V AC decorative type with driver including LED lamp, connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F Energy efficient five star rated, 26 to 32 Watts, with three blades ceiling fan 230 volts, single phase AC, 1200 mm sweep, BEE 5 star rated, Brushless Direct Current(BLDC) without remote type with accessories like holding down rod,hanging clamps, blades, fan hook including writing MES number (as per standard practice) including provision of three core flexible copper wire of suitable size from ceiling rose to ceiling fan complete in all respect all as specified and directed.
S&F exhaust fan metallic steel body, single phase, 230 volts, 50 Hzs of size 225/230mm sweep, 900/950 RPM, copper wound, 3 blade, double ball bearing, heavy duty type with suitable metallic louver, blades, frame and flexible three core copper conductor cable of suitable size for connecting with ceiling rose complete all as specified and as directed.
& F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S & F porcelain insulator with nut bolt and washer on wall to fix the strip of copper strip complete all as specified and as directed.
S & F MS cubical shape of enclosure make 3.15 mm thick with front operation door and locking arrangements, fixing screws, duly painted of overall dimension 200 x 100x 75 mm for installation test point complete all as specified and as directed.
S & F integral LED Aviation obstruction light comprising of aluminium housing with polycarbonate enclosure clear thick glass and accessories including fixing materials i.e. MS clamps, Nut & bolts etc complete all as specified and as directed.
S&F Sheet metal enclosure for DBs, single door, single pole and neutral 2 way along with one No MCB SPN 10 Amps all as specified and directed.
M&L for wiring for circuit/ submain wiring alongwith earth wire with the 2x2.5 sq. mm +1x2.5 sq. mm earth wire sizes of FR PVC insulated copper conductor, single core cable drawn in PVC conduit in surface/ recessed as required complete all as specified and directed
Design, supply, install, testing & commissioning goods lift of capacity 500 kg , speed 0.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+04 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) complete all as specified and directed. Note: (i)The lift shall comprise of all safe measures as specified in relevant IS Codes (IS:14665 of 2015: Part-I, IS:14665 of 2009: Part-V, IS:4591 of 2012, IS:15785 of 2007 ) and National Building Code - 2016 as revised from time to time. (ii) the contractor shall done the comprehensive maintenance of electrically operated lift including Repairs/Replacement of defective/ unserviceable parts like LCD display, electromechanical locks, safety devices of lifts and accessories of the lift etc during Defect Liability period of 02 (Two) years from the date of completion of work. The contractor shall borne the expenditure occured during maintenance in Defect Liability Period of two years from the date of completion of work and the amount of same deemed to be including in quotated rate by the contractor. (iii) The contractor shall provide MOU with the OEMs for the provision of the lift and further maintenance. The MOU for the post warranty/ post defect liability period between the contractor and OEM shall be submitted at least six months prior to the issue of completion certtificate of the main contract.
Serial Item No. 16.41 (Contd....) Note: (a) Lift shall be run by electric motor driven mechanism with incline room elevator. Contractor shall providemild steel shaft and connected accessories for running lift from bottom to top including preparation of wall at all angle with smooth finish before fixing shaft and lift accessories into the pit of lift space. (b) Contractor shall arrange adequate resources to measure the lift space, pit size, dimention of car and travel height etc. at site before ordering the product. Drawing of lift with all dimentions recommended by OEM shall be approved by GE prior to the ordering of items. (c) Contractor shall get the drawing of lift desing from GE(P)(AF) Kalaikunda before dispatch the product (d) Contractor shall provide arrangements for factory inspection of GE(P)(AF) Kalaikunda. (e) Intirior, colour and design of car, lighting, ventilation and landing floor finish shall be approved by GE(P)(AF) Kalaikunda before installation of lift. (f) Contractor shall submit original OEM test certificate and CP vouchers before payment. (g) All kind of tools, maintenance and manpower shall be arrangement by the contractor during installation, testing and commissioning. (h) Minor cutting, dressing and drilling or any minor civil work and making good of the disturbed portion shall be borne by the contractor while installation. (j) He shall impart adequate training to the user and MES staff for smooth operation of lift. (k) Microprecessor, lifting mechanism, brakes, speed control governors, all king of wirings, internal electric connections, communication cables from ground floor to top floor shall be done by the contractor. (l) Contractor shall provide arrangement for inserting cable for CCTV cameras in the lift. (m) total stoppage shall be at G+1+2+3+4. (n) Each floor shall have separate door for automatic opening and closing. (o) Car door, car wall and car ceiling shall be of stainless steel material with high durability. (p) Contractor shall provide arrangements, scaffolding structures and misc associated all king of works for installation of lift.
Supply, install, testing and commissioning of factory made indoor cubical type LT feeder piller box of 1.5 x 1.2 x 0.9 m size totally enclosed weather ,dust vermin proof made of angle iron frame 50mm X50mm X 6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and 2mm thick CRCA (cold rolled cold annealed ) MS sheet bend to shape ,front & back side operated double door with proper hinge and locking arrangement and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB, Bus bar cable alley. 200 Amp size of bus bar shall be insulated with colour code/sleeves /tapes sincluding necessary PCC (1:3:6) type C2 for foundation /Platform all as specified and directed. LT panel board for Lift shall be complied in all respects with and including the following accessories:- (a) INCOMING (i) MCCB 100 Amp 4 Pole, 415 Volt with thermal magnetic 25 KA. - 01 Nos (ii) Panel mounted digital multifunctional meter in 96X96 Sqmm flush mounted case SP, accuracy class 1.0,0.5, voltage measuring rane 50-520VAC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A, F, PF, kW, kVA, kWh/kVAh. (iii) Indicator Lamp - R - Y - B (Set of three). ---01 No (b) OUTGOING (i) MCCB 3 Pole, 415 V, 50 Amps with breaking capacity 10 KA. ---01 No (ii) MCCB 3 Pole, 415 V, 40 Amps with breaking capacity 10 KA. ---01 No
Supply, installation, testing and commissioning of Silent Diesel Engine driven generating set 415 Volts, 3 phase 4 wire, engine as per IS : 10001/10002 and alternator as per IS : 13364 complete with relay panel for automatic starting on mains failure, control panel having meters, sound proof canopy and concrete foundation etc. of capacity 650 KVA 4 Stroke, designed to run 1500 RPM complete all as specified and directed comprising of following accessories:- A) Diesel Engine:- (i) Radiator Cooling (ii) Radiator fan with guard (iii) Fly wheel with starter ring (iv) Dry type air cleaner (v) Vacuum indicator (vi) Mechanical Governor (vii) Exhaust Silencer (viii) Fuel filter (ix) Inline Fuel pump (x) Water pump (xi) Lub oil filter (xii) Lub oil pump (xiii) 24 V electric start system complete with starter, battery charging alternator. (xiv) Engine control panel consisting of starting key switch, lub oil pressure gauge ammeter safety shut down system for low Lube oil pressure & High coolant temperature Engine maintenance manual with spare parts list. (xv) Exhaust pipe/ stack up to 6.0 meter from top of shed with insulation, structural steel required for supporting exhaust pipe/stack, fixed, sliding supports etc. (xvi) First fill of lube oil & coolant (xvii) Residential Silencer with cladding & supports
Supply and installation high wall electrically driven single phase split AC unit indoor/outdoor complete with cordless remote control unit and with inbuilt air ioniser and plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of 1.5TR capacity complete all as specified and directed.
Supply, installation and commissioning of water cooler storage type with fully stainless steel, electric driven 230 V 50 Hz single phase supply com PUF insulation, adjustable cold water thermostat, auto cut facility, overload protection, stainless steel front pane, extended plastic egs, eco-friendly version with Refrigerant-134A, reciprocating type compressor and approximate storage capacity of 80 ltrs and nominal cooling capacity of 40 ltrs per hour all as specified and as directed.
Supply, installation and commissioning Table lamp with 6 W LED single Phase 230 Volts 50 Hz complete all as specified and as directed.
S&F Hand dryer 230 Volts single Phase smart flow stainless steel body complete all as specified and as directed.
S&F Medium size Chandelier with colourful lighting complete all as specified and directed.
M&L Wiring for PA system with 0.5 Sqmm copper conductor cable complete all as specified and directed.
S&F electric water heater storage type steel body with stainless steel inner tank and heating element upto 1.5/2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, including PVC connection pipe for hot/ cold water to existing water lines,necessary fixing arrangement by using 50 X 5 mm MS plate and writing MES No and paste the instruction sheet of Do’s and DO NOT complete all as specified and as directed.
S&F for Rigid non-metallic PVC conduit 25 mm external dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed.
Supply and fixing of Network Repeater panel is based on network technology, providing remote control and indication of the fire alarm system : Provide remote display and control of system, Password protected access level; 8x18 characters LCD screen, 15 LEDs to display important information, functional control of network panels, Network-wide operation: Acknowledge, Silence, Reset, Flush-Mount or surface-mount structure. Make : GST/Siemens/Apollo/Morley
Supply,install,testing & commissioning of Automatic Fire Suppression system with all fittings, fixtures and all accessories as given below:- (i) 2c x 1.5 sqmm CU Armoured LT cable 1100 volts - 160 RM (ii) Clean agent storage cylinder, high pressure seamless carbon steel cylinder, test pressure 300 Bar, working pressure 200 Bar and dia 365mm, PESO approved of capacity 100 Ltrs - 02 Nos (iii) Corner Pulleys are used to chane the pipe directions and smooth running of SS wire - 06 Nos (iv) Manual Pull Station along with glass covered box (M.S.) Manual Activation Mechanical - 01 Nos (v) MS Container strap for mountibg and fixing the agent container to the wall - 06 Nos (vi) SS Wire used to pull the manual control head through manual pull station 1.5mm - 12 RM (vii) Wire sleeve ( steel wire runs into the aluminium conduit via a system of pulleys provided at each bend) of Outer dia 10mm & Inner Dia 8mm - 12 RM (viii) End of line for SS wire - 02 Nos (ix) HFC 227ea Gas (1,1,1,2,3,3,3 Hepta fluro propane), zero OPD, Stored pressure - 150 KG (x) Brass Discharge Nozzle are designed to provide the proper flow rate and distribution of agent to total flood a hazard area: 180 deg/360 deg. End connection-female thread type(NPT/BSPT) - 04 Nos (xi) Manifold fabricated from seamless pipe(S) MS Seamless to ASTM A-106, Sch. ( 3 way) - 01 Nos (xii) Valve assembly and arrangement for supervisory switch connection for monitoring cylinder pressure, a pressure guage with a safety burst disc and a safety cap. - 03 Nos (xiii) Electric control head (solenoid actuator) used for releasing the gas, Electrically operated, Voltage range b24V DC, Ambient temp 55 Deg C, IP m65 protection, mounted over the cylinder valve - 01 Nos (xiv) Manual (Mechanically Operated) control head (Brass) to operate the system pulling the mechanical lever with the help of SS wire & manual pull station, mounted over the solenoid actuator - 01 Nos (xv) Manifold check valves are installed at the inlet of discharge manifold in case multiple cylinder arrangement to allow removal of agent cylinder from manifold while still retainung a closed system - 03 Nos
Serial Item No. 16.56 (Contd....) (xvi) Actuation hose used in master and slave cylinder systems to actuate slave cylinders - 02 Nos (xvii) Actuation Adaptor is used to connect the actuation hose to cylinder valve - 04 Nos (xviii) Pressure guage cum switch for monitoring the cylinder pressure 0-60 bar, 38 bar switch point - 03 Nos (xix) Brass pneumatic actuator allow for pneumatic actuation of slave's cylinder valves in case of master and slave, mounter directly on the top of slave cylinder valve - 02 Nos (xx) Flexible discharge hose route the agent from master/ main storage cylinders to the discharge piping by a flexible rubber hose with wire braided reinforements. This hose is connected to the discharge outlet of cylinder valve and terminated at the system piping or discharge manifold for master cylinder - 03 Nos (xxi) conventional, Gas release panel with battery backup and cross zoning facility. (2-Zone) - 01 Nos (xxii) Manual abort switch operates as electrical emergency hold device for gas extinguishing systems - 01 Nos (xxiii) ERW MS pipe heavy duty seamless piping for fire automatic fire supression system. The pipe shall be fixed on wall or suspended from ceiling including necessary specials such as bends, reducers, orifice plates if any tees, flanges, MS tapers etc. as per ASTM A-106 SCH-40. The rate shall be included the cost of consumables for utting and welding and painting with two coats of red oxide and two coat post office red colour for :- (a) 50 mm dia bore - 60 RM , (b) 25 mm dia bore - 30 RM complete all as specified and directed. Note: If any connected item not catered in Item no 28 and is required for smooth functioning/working of automatic fire supression system, the contractor has to provide the same without any extra cost to the department.
Supply and install safety accessories for fire safety as following :- (a) Clean Agent fire extinguisher of 6 kg as per IS 15683 - 02 Nos (b) Light weight squeeze grip type CO2 Extinguisher of capacity 2kg as per IS 15683 - 02 Nos (c) Fire buckets - 02 Nos with stands - 01 Set (d) Fire aid box containing First Aid medicines including First Aid laminated chart (Electric shock treatment duly written in English, Hindi,Bengali) complete all as directed - 02 Nos (e) Hand gloves for 11 KV line testing on 15 KV - 04 Nos (f) Extinguishers bucket acc 24 SWG 9 Ltrs No 1-IC-875- 04 Nos
Supply,install,testing & commissioning of factory made indoor cubical type LT feeder piller Box of 1.5 x 1.2 x 0.9 m size totally enclosed weather ,dust vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and 2mm thick CRCA (cold rolled cold annealed ) MS sheet bend to shape ,front & back side operated double door with proper hinge and locking arrangement and painting panel board complete with two coats of powder coated paint over a coat of re oxide primer with spray painting on internal and external surfaces and shall be complete incld internal wiring using with suitable size of copper conductor cables and aluminium strips for incoming and outgoing connections of all switches/MCB's,/MCCB',Bus bar cable alley. 200 Amp size of bus bar shall be insulated with colour code/sleeves /tapes sincluding necessary PCC (1:3:6)type C2 for foundation /Platform all as specified and directed.LT panel board for Fire fighting bldg shall be comple in all respects with and incld the following accessories:- (a) INCOMING (i) MCCB 125 Amp 4 Pole, 415 Volt with thermal magnetic 25 KA. - 01 Nos Make - Havells ---01 No (ii) Panel mounted digital multifunctional meter in 96X96 Sqmm flush mounted case SP, accuracy class 1.0,0.5, voltage measuring rane 50-520VAC, CT secondary site suitable 1A/5A, programmable CT/PT to measure V,A, F, PF, kW, kVA, kWh/kVAh. (iii) Indicator Lamp - R - Y - B (Set of three). ---01 No (iv) Single phase preventer--01 No (b) OUTGOING (i) MCCB 3 Pole, 415 V, 100 Amps with breaking capacity 25 KA. ---03 No (ii) MCCB 3 Pole, 415 V, 32 Amps with breaking capacity 10 KA. ---02 Nos (iii ) Fully automatic star delta starting arrangement suitable for 20HP Submersible pumping set----01 No
Comprehensive maintainance of 01 No electrically operated lift of capacity 500 kg lift suitable for serving G+4 floors with electric power operated doors, auto electric levelling device complete with ARD facility installed at ATC for a period of one year ( 1st year after expiry of Defect Liability Period). Repairs/Replacement of defective/ unserviceable parts like LCD display, electromechanical locks, safety devices of lifts and accessories of the lift etc and in addition of breakdown maintenance to the monthly, half yearly and yearly maintenance as per mentioned in company catalogues. Contractor shall carry out break down maintenance also. In case of break down, the contractor's mechanic should reach at site within one hour whenever any break down is reported to the contractor OR his reperesentative telephonically/email or any other media of communication. The contractor shall specify their office/residence/ work place phone numbers or mobile numbers for lodging break down complaints round the clock i.e., 24x7 Hrs. Note :- 1. Activities covered in the above schedule are not exhaustive. If any activity required being included later on due to reliability and safety shall be carried out by the contractor without any extra cost. 2. The contractor shall enter into a MOU with the OEMs for the provision of the lift and further maintanance. The MOU for the post warranty/ post defect liability period between the contractor and OEM shall be submitted at least six months prior to the issue of completion certtificate of the main contract. 3. Maintenance of lifts shall be maintained through OEM Only.
All as per Srl item No.16.60 here-in-before but for next 11 Months after completion of 11 Months after Defect Liability Period
All as per Srl item No.16.60 here-in-before but for next 11 Months after completion of 22 Months after Defect Liability Period
S&F MCCB 415V, 4P, 250 Amps, 50 Hz, 36 kA with thermal magnetic release type complete all as specified and directed.
S&F MCCB 415V, 4P, 100 Amps, 50 Hz, 25 kA with thermal magnetic release type complete all as specified and directed.
M & L for boring for bored cast in situ piles 250mm dia of piles 32 mtr in soil and getting out sand disposal of spoil to a distance of 50 mtrs using DMC method complete all as specified and as directed.
S & F 100mm dia CI Pipe of 2 mtr length with CI cowls on top as vent pipe at recharge pit complete all as specified and as directed.
S & F UPVC 200mm dia plain pipe complete all as specified and as directed.
S & F UPVC 200mm dia slotted pipe complete all as specified and as directed.
SCHEDULE "A" PART-XVII (SCHEDULE OF CREDIT) Note :- Amount of Rs. 43850.00 indicated in Tender as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
NIRMAL SALES CORPORATION (BID ID -3151982)
M/s godara infratech and power industries (BID ID -3157005)
BHOWMICK ENTERPRISES INDIA (BID ID -3147117)
NARSINGH DEVELOPERS LLP (BID ID -3151916)
D R STEEL CONSTRUCTION COMPANY PRIVATE LIMITED (BID ID -3151933)
DNS CONSTRUCTION COMPANY (BID ID -3151924)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid