| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹14.5 LAccepted-AOC AT OLD B D O OFFICE MAIN ROAD PHUSRO DIST BOKARO JHARKHAND | BOKARO | JHARKHAND | 825102 | L-1 | Accepted-AOC Deposited performance security money | |
| 2 | Rejected-Technical | - | Rejected-Technical Technically disqualified |
| Sl No | Description | Qty | Unit | Balajee Traders L1 |
|---|---|---|---|---|
| 1.00 | Providing of Ferrules,lugs, clips, socket wiring belts for circuit wiring. | 10 | Nos | 2,500 ₹25,000 Lowest |
| 2.00 | Providing of power pack unit/Rectifire unit, 110V AC/DC supply. | 2 | Nos | 10,000 ₹20,000 Lowest |
| 3.00 | Providing of Arc chute in oil tank (OCB) | 3 | Nos | 4,500 ₹13,500 Lowest |
| 4.00 | Providing of P.T fuse moulded type 3Amp. | 8 | Nos | 3,200 ₹25,600 Lowest |
| 5.00 | Providing of main moving contact 400Amp | 1 | Nos | 3,400 ₹3,400 Lowest |
| 6.00 | Providing of main fixed contact 400Amp | 1 | Nos | 5,200 ₹5,200 Lowest |
| 7.00 | Providing of C.T 100/50/5A, moulded type 3.3KV & 11KV, 10VA, STC 13.1 KA for 1 sec. | 5 | Nos | 20,000 ₹1,00,000 Lowest |
| 8.00 | Providing of Rotary switch (mechaincal type) in operating mechanism | 5 | Nos | 4,850 ₹24,250 Lowest |
| 9.00 | Providing of selector switch volt & Amp,16Amp | 12 | Nos | 1,000 ₹12,000 Lowest |
| 10.00 | Providing of spout bushing insulator 3.3KV & 11KV,400A | 2 | Nos | 20,000 ₹40,000 Lowest |
Tender Value
₹13.5 L
EMD Value
₹17,000
Closing Date
26 Mar 2025, 6:55 pmClosed
SO(EnM), BnK
GM Office, BnK Area, Bermo, Bokaro, Jharkhand.
Repair and running maintenance of 7 nos. 3.3KV n 4 nos, 11KV grade, switchgear different make and different location Installed at MBSS, BnK Area.
2025_CCL_332179_2
SO(EnM)/e-tender/24-25/35
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
MRSS
As per NIT
2 documents required · 2 mandatory
₹17,000
12 Sept 2025
11 Mar 2025
28 Mar 2025
11 Mar 2025
26 Mar 2025
12 Mar 2025
11 Mar 2025 - 18 Mar 2025
Amount
Providing of Ferrules,lugs, clips, socket wiring belts for circuit wiring.
Providing of power pack unit/Rectifire unit, 110V AC/DC supply.
Providing of Arc chute in oil tank (OCB)
Providing of P.T fuse moulded type 3Amp.
Providing of main moving contact 400Amp
Providing of main fixed contact 400Amp
Providing of C.T 100/50/5A, moulded type 3.3KV & 11KV, 10VA, STC 13.1 KA for 1 sec.
Providing of Rotary switch (mechaincal type) in operating mechanism
Providing of spout bushing insulator 3.3KV & 11KV,400A
Providing of needle bush shaft in operating mechanism.
Providing of latch lever set in operating mechanism.
Providing of trip bar set in operating mechanism.
Providing Eart leakage relay Flush Mounted Aux Supply-80-300AC/DC, 300-1200mA.
Providing kit- kat type fuse (Bakelite type)6Amp
Providing and fixing of Potential Transformer 160VA/PH, PTR-3.3KV/110V 3Phase,3 LIMB, Fixed, Epoxy casted, 3.3KV
Providing of Am meter, 4"x 4" size digital type, 5Amp oprated, different ratio as 400/200/5, 200/100/5, 300/150/5 etc.
Providing of Test/reset switch NO/NC Auxilary type.
Providing of Volt meter 4"x 4" size, digital type, PTR 3.3KV/110V
Providing of CBCT for Earth leakage relay, 3.3KV & 11KV, 2" Dia, epoxy resin cast
Providing of Auxiliary contactor 110V coil opreated, 4 NO+4NC for controlling circuit of IDMT relay.
Providing of Push switch auxilary NO+NC type, 110V opreated for on/off
Providing & fixing of Complete gasket in oil tank cover, insulator fixing point & other required places, 10 mm thickness
After repairing of switchgear all protective relays testing by secondary injection/relay testing machine as well as testing/ measuring of meters, indicators etc.
Complete body cleaning, Double coat primer and Enamel painting by Spray painting machine including cost of cleaning and painting materils as well as labour cost.
Repairing/setting, overhauling of opreating mechanism cleaning, washing by suitable Oil, Providing of lubricants in all moving joints etc.
Repairing & rectification of control circuit wiring.
Overhauling of bus-bar system with repairing by drilling, cutting, shape making and setting, as well as complete insulation covering.
Repairing/ overhauling and commissioning of switch, such as insulation painting of all insulators, P.T, C.T etc as well as Tightening of all loose connections/point.
Supervision , incidental & overhead expenses
Total impact of GST for the purpose of CTC
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .