| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 CrAdmitted-Finance | ₹8.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹8.4 Cr+₹25.1 L (3.09%)Admitted-Finance | ₹8.4 Cr+₹25.1 L (3.09%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MOHD SALEEM L2 | Sanjiv Kumar Sharma L1 |
|---|---|---|---|---|---|
| 1.00 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms , incl. disposal or filling of excavated earth wherever required as per the directions of Engineer-in-charge . | 2,030 | Cum | 150 ₹3,04,500 Lowest | 200 ₹4,06,000 |
| 2.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, incl. all leads and lifts. | 1,010 | Cum | 90 ₹90,900 Lowest | 150 ₹1,51,500 |
| 3.00 | Supplying and filling in plinth with fine sand under floors including, watering,ramming, consolidating and dressing complete | 375 | Cum | 300 ₹1,12,500 | 10 ₹3,750 Lowest |
| 4.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level 1:4:8 (1 cement: 4 fine sand : 8 graded stone aggregate 40mm nominal size) incl. all leads, lifts & carriage of material by MT / H.L. | 175 | Cum | 3,099 ₹5,42,325 | 2,000 ₹3,50,000 Lowest |
| 5.00 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) incl. all leads, lifts & carriage of material by MT/ H.L. | 365 | Cum | 3,999 ₹14,59,635 Lowest | 4,500 ₹16,42,500 |
| 6.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centring & shuttering- All work upto plinth level 1:2:4 (1 cement: 2 coarse sand : 4 graded stone agg. 20mm nominal size) including all leads, lifts & carriage of material by MT / H.L. | 66 | Cum | 4,900 ₹3,23,400 | 2,000 ₹1,32,000 Lowest |
| 7.00 | Providing and laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1cement:2 coarse sand: 4 graded stone agg. 20 mm nominal size) & curing complete incl. all leads, lifts & carriage of material by MT/ H.L. | 1,162 | Sqm | 190 ₹2,20,780 Lowest | 300 ₹3,48,600 |
| 8.00Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. | |||||
| 8.01 | All works upto plinth level | 785 | Cum | 5,999 ₹47,09,215 Lowest | 7,800 ₹61,23,000 |
| 8.02 | All works above plinth level upto floor V level | 1,126 | Cum | 6,299 ₹70,92,674 Lowest | 8,000 ₹90,08,000 |
Tender Value
₹10.2 Cr
EMD Value
₹20.3 L
Closing Date
11 Feb 2022, 4:00 pmClosed
Executive Engineer PWD R and B division Kathua
Executive Engineer PWD R and B division Kathua
Please refers to BOQ
2022_PWDJK_159333_1
e-NIT No. 194 of 2021-22/13155-64/G dt 03-02-2022
Open Tender
Civil Works - Roads
Item Wise
730 days
Kathua
Please refers to NIT and SBD
8 documents required · 8 mandatory
₹6,000
Executive Engineer PWD R and B division Kathua
₹20.3 L
Chief Engineer PW(R and B) Department Jammiu
23 Feb 2022
4 Feb 2022
12 Feb 2022
4 Feb 2022
11 Feb 2022
4 Feb 2022
9 Feb 2022
Amount
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms , incl. disposal or filling of excavated earth wherever required as per the directions of Engineer-in-charge .
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, incl. all leads and lifts.
Supplying and filling in plinth with fine sand under floors including, watering,ramming, consolidating and dressing complete
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering- All work upto plinth level 1:4:8 (1 cement: 4 fine sand : 8 graded stone aggregate 40mm nominal size) incl. all leads, lifts & carriage of material by MT / H.L.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) incl. all leads, lifts & carriage of material by MT/ H.L.
Providing and laying in position cement concrete of specified grade excluding the cost of centring & shuttering- All work upto plinth level 1:2:4 (1 cement: 2 coarse sand : 4 graded stone agg. 20mm nominal size) including all leads, lifts & carriage of material by MT / H.L.
Providing and laying damp-proof Course 40 mm thick with cement concrete 1:2:4 (1cement:2 coarse sand: 4 graded stone agg. 20 mm nominal size) & curing complete incl. all leads, lifts & carriage of material by MT/ H.L.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge.
All works upto plinth level
All works above plinth level upto floor V level
Extra for providing richer mixes at all floor levels. Note:- Excess/ less cement over the specified cement content used is payable/ recoverable separately. Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum)
Centring and shuttering including strutting propping etc and removal of form work
Foundations, footings, bases of columns etc. for mass concrete.
Suspended floors, roofs, landings, balconies and access platforms.
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, pillars, piers, abutments, posts and struts.
Stairs (excluding landings) except spiral staircases
Edges of slabs and breaks in floors and walls under 20 cms wide.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto all level Thermo-Mechanically Treated bars of grade Fe-500D or more incl. all leads, lifts and carriage of material by M.T. / H.L.
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth including all shapes, leads, lifts and carriage of material by MT / H.L. in cement mortar 1:6 ( 1 cement : 6 coarse sand)
Extra for brick work in superstructure above plinth level upto floor V level (By manual means) incl. all leads, lifts & carriage of material by M.T. H.L.
Half brick masonry with bricks of class designation 75 in foundations and plinth in cement mortar 1:4 ( 1 cement :4 coarse sand) incl all leads, lifts & carriage of material by MT / H.L.
Extra for half Brick masonry in superstructure above plinth level upto floor V level incl all leads, lifts and carriage of material by MT / H.L.
Making plinth protection 50 mm thick of cement concrete 1:3 : 6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm bed of dry brick ballast 40 mm nominal size well rammed & consolidated & grouted with fine sand including finishing the top smooth. Crushed aggregate including all leads, lifts and carriage of material by MT/H.L.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete incl.all leads, lifts & carriage of material by MT / H.L.Size of tile 600x600 mm Double Charge.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying 18 mm thick gang saw cut of specified thickness, mirror polished pre- moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in- Charge.
18 mm thick Flooring with marble stone of specified thickness as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4 coarse sand) laid and jointed with grey cement slurry including rubbing, polishing and curing complete with:Agaria White
Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Marble Work
Chequerred precast cement concrete tiles 22mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand) . Medium shade using 50% white cement and 50% ordinary cement.
P/F aluminum work for doors, windows, ventilators & partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required incl. cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)For fixed portion Powder coated aluminum (minimum thickness of powder coated 50 microns)
P/F aluminum work for doors, windows, ventilators & partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required incl. cleat angle, Aluminum snap beading for glazing/panelling, C.P. brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required incl. the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.)Powder coated aluminum (minimum thickness of powder coated 50 microns)
Providing and fixing Anodized aluminum grill (Anodized transparent or dyed to required shade according to IS: 1868 minimum anodic coating of Grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing windows frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved Anodized aluminum standard section around the opening, all complete as epr requirement and direction of Engineer-in-charge. (only weight of grill to be measured for payment)
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in- charge. (Cost of aluminum snap beading shall be paid in basic item.) With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)
Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all completeWith Galvanized M.S. Wire gauge with wire of dia 0.63 mm
Providing and applying White Cement based Putty of average thickness 2 mm of approved brand & manufacture, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and fixing aluminum tower bolts SI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc complete
Providing and fixing aluminium hanging floor door stopper ISI marked anodised(anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Single rubber stopper
Providing and fixing aluminium sliding door bolts 300x16 mm ISI marked anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc complete
Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete :
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Providing wood work in Sal wood frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):
Providing and fixing 35 mm thick panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excl. panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.Second class deodar wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Particle Board 12mm thick Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked
Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws, (Shutter area to be measured).
6 mm thick plaster to ceiling of mix 1 : 3 ( 1 cement : 3 fine sand) incl. all leads, lifts and carriage of material by M.T / H.L.
15mm cement plaster on rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) incl. all leads, lifts & carriage of material by M.T / H.L.
12mm Cement plaster of mix: ( 1 cement : 4 fine sand) incl. all leads, lifts & carriage of material by MT / H.L.
12mm Cement plaster finished with a floating coat of neat cement of mix:1:3 (1 cement : 3 fine sand ) incl. all leads, lifts & carriage of material by MT / H.L.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes reparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing & laying integral cement based water proofing treatment incl.preparation of surfaces as req. for treatment of roofs,balconies, terraces etc consisting of following operations.a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 & approved by Engineer-in-charge over the RCC Slab incl. adjoining walls upto 300mm height incl. cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in- charge to req. slope & treating similarly the adjoining walls upto 300mm height incl. rounding of Junctions of walls & slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 & approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 & approved by Engineer-in-charge incl. laying glass fibre cloth of approved quality in top layer of plaster & finally finishing the surface with trowel with neat cement slurry & making pattern of 300x 300 mm/sq 3mm deep.e) The whole terrace so finished shall be flooded with water for a min. period of two weeks for curing & for final test. All above operations to be done in order & as directed & specified by Engineerin-charge. With avg. thickness of 120mm and min. thickness at khurra as 65 mm
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ liter of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats
Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm
Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete incl. all leads, lifts & carriage of material by MT/ H.L.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone agg. 10 mm and down gauge), incl. finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase.
Supplying and laying including digging, carrying by lorry, filling River Bed Material including watering & consolidation in layers to specified lines, camber, grades and cross sections. Finished work including material , labour all leads , lifts and carriage of material by MT/HL.
Providing and fixing Inaguration stone of granite(size 3'0"x2'0") incl. engraving writing and fixing in wall including Construction of Pedestal Complete Job
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. ( Make - Jaquar CNS - WHT - 453 )
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlleddevice (handle lever), conforming to IS:7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required. W.C. pan with ISI marked white solid plastic seat and lid ( Make - Jaquar CNS - WHT - 555 SNL )
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. ( Make - Jaquar FLS - WHT -5301 )
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, includingpainting of fittings and brackets, cutting and making good the wallswherever required :Kitchen sink without drain board 610x510mm bowl depth 200mm( Make - Jayna SBSD -01 )
Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931(Make - Jaquar CON - 037 KN ).
Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms( Make - Jaquar CON - 107 KN )
Providing & fixing 15mm nominal bore C.P. brass angle valve for basin mixer and gyser points of approved for conforming to IS : 8931
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete ( Make - Jaquar CHT - 083 KN )
Semi rigid pipe 40 mm dia
Semi rigid pipe 40 mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete
Providing and fixing 600x120x5mm glass shelf with edges round off supported on anodized aluminum angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc. complete
Providing and fixing toilet paper holder C.P. brass (Make - Jaquar AKP 35751 P).
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with brackets of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms (Make - Jaquar ACN 1135 N )
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms (.Make - Jaquar ACN1121 N )
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: 600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms. ( Make - Jaquar AQN 7711 B )
Providing and fixing unplastised P.V.C. connection pipe with PTMT Nuts of approved quality,colour[for connection to Mixers & taps from angle valve. ( Make - Jaquar ALD 803 B )15 mm nominal bore with 45cm length.
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet. 150 mm diameter ( Make - Jaquar SHA 477 )
Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931 ( Make - Jaquar CON - 053 KN )
Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. ( Make - Jaquar CON -167 KNB )
Providing and fixing PTMT soap dish holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms ( Make - Jaquar ACN1131 N )
Providing & Fixing C.P brass 32 mm size bottle trap of approved quality & make as approved by engineer - in - charge . ( Make - Jaquar ALD 769 L & ALD 709 )
Providing & Fixing15 mm nominal dia Single lever telephonic wall mixer of approved quality & make as approved by the engineer - in - charge . ( Make - Jaquar HSH 1929 )
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white viterous china flushing cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litre), including seat cover, and cistern fittings, nuts, bolts and gasket etc. complete. ( Make - Jaquar FLS WHT 5951 & CNS WHT 201 C )
Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
Providing and fixing C.P. brass twin coat hooks fixed on toilet door with C.P. brass screws incl. all fittings complete. (Make - Jaquar ACN1161 N )
Providing and fixing health faucet with 1 m PVC tube and swivel hook including all fittings complete. ( Make - Jaquar ALD 563 )
Providing & fixing C.P. brass central hole Sink Mixer Tap with complete accessories as required. ( Make - Jaquar CON 319 KN )
Providing and fixing PVC Floor trap of approved quality.100 mm dia
Providing and fixing PVC Floor trap of approved quality.150 mm dia
Providing and fixing vertical or horizontal storage type hot water heater fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug . ( Make - Venus 15 YVH & 25 YVH )
Geyser 15 liter
Geyser 25 liter
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover & suitable locking arrangement of Finolex, Sintex or Vectus or equivalent make and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank ( Make - Sintex or as per approved local Manufacturer )
Providing and fixing of 25 mm thick duly laminated aluminum foil of mat finish closed cell Nitrile rubber (class“O”) insulation on existing water tank after applying Suitable adhesive for nitrile rubber. The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. ( Make - Kaiflex / Careflex / Armaflex )
Providing and fixing Accoustic Home Technique-PP/Polypropylene piping (PP) piping system with built-in SOCKET pipe in 3 LAYER made of PP-H (Grey)/PP-C (Blue/Ral) outer layer + foam (PP-H)/PPMV middle layer + PP-H white/PP-C (Blue/Ral), push-fit type, food safe, having moderate impact and stiffness, density of pipe not above 1.35 gms/cm3 and not below 0.75gms/cm3, elongation not less than 0.05mm/m⁰K and not more than 0.15mm/m⁰K, chemical resistance as per ISO/TR 10358, the system should be workable from 0 degree to + 90 degree C (short term thermal resistance) with all necessary single molded fittings in grey/blue/ral colour, fitted with factory fitted lip ring including painting for external installation. Connection with mugs and gasket made of EPDM or rubber (EN 681) (supporting standard as per EN 1451) - Noise level equal to or less than 22dBA @ 2lps as per VDI 4100 and 25dBA as per EN14366/DIN 4109 with BISMAT 2000 clamps as per Fraunhofer certification. (Make - Poloplast / Rehau / WOVIN AX )
75 mm dia
110 mm dia
Providing & fixing PVC Waste pipe of 4 kg Pressure of Supreme/Finolex conforming to IS: 13592 Type-A incl. jointing with sealing of approved quality
75 mm dia
110 mm dia
150mm dia
Providing and fixing on wall face un-plasticized - PVC moulded fittings/ accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion
Bend 87.5° 110 mm bend
150mm dia Bend
Providing and fixing Accoustic Home Technique-PP/Polypropylene piping (PP) piping system with built-in SOCKET pipe in 3 LAYER made of PP-H (Grey)/PP-C (Blue/Ral) outer layer + foam (PP-H)/PPMV middle layer + PP-H white/PP-C (Blue/Ral), push-fit type, food safe, having moderate impact and stiffness, density of pipe not above 1.35 gms/cm3 and not below 0.75gms/cm3, elongation not less than 0.05mm/m⁰K and not more than 0.15mm/m⁰K, chemical resistance as per ISO/TR 10358, the system should be workable from 0 degree to + 90 degree C (short term thermal resistance) with all necessary single molded fittings in grey/blue/ral colour, fitted with factory fitted lip ring including painting for external installation. Connection with mugs and gasket made of EPDM or rubber (EN 681) (supporting standard as per EN 1451) - Noise level equal to or less than 22dBA @ 2lps as per VDI 4100 and 25dBA as per EN14366/DIN 4109 with BISMAT 2000 clamps as per Fraunhofer certification. (For Indirect waste/ Wash Basin/Urinal/Sink/Floor Drain ) (Make - Poloplast / Rehau / WOVIN AX)
Providing and fixing uPVC Trap with minimum 50mm water seal with rubber seal on inlet to push fit hopper for indirect waste connections. (Make - Supreme/ finolex/ AKG )110 mm inlet & 110 mm outlet.
Providing and fixing clean out pipe (door piece) for cleaning. (Make - Poloplast / Viega / Mcalpine/ WOVIN AX )110 mm dia.
Providing, fixing, testing and commissioning of pipe inlet fittings fabricated with PoloPlast/uPVC Pipe with maximum 3 inlets 40, 50 & 75 mm OD size poloplast pipe, fixed to 'P' traps including Dripseal/Pipe seal/solvent weld joint/rubber ring joint complete . (Make - Poloplast / Viega / Mcalpine/ WOVIN AX )
Providing and fixing floor drain (FD) with 50mm outlet and 100 mm inlet with SS grating having 19mm seal for indirect floor drain (FD) (Make - Poloplast / Viega / Mcalpine/ WOVIN AX )
Providing and fixing stainless steel grating of approved quality and colour. 100 mm nominal dia.
Providing and Fixing stainless steel grating with rim of approved design including setting in floor with cement mortar. (For Floor Trap/Floor Drain) (Make - Neco / neer )125 mm x 125 mm
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, incl. cutting and making good the walls etc. Internal work-Exposed on wall
15 mm dia. nominal bore medium
20 mm dia. nominal bore medium
25 mm dia. nominal bore medium
32 mm dia. nominal bore medium
40 mm dia. nominal bore medium
50 mm dia. nominal bore medium
65 mm dia. nominal bore medium
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.:Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall:
15 mm dia. nominal bore
20 mm dia. nominal bore
Providing and fixing G.l. pipes complete with G.l. fittings including trenching and refilling etc. (external work) ( Make - Tata / Jindal Hissar / Jindal Ghaziabad )
40 mm dia. nominal bore
50 mm dia. nominal bore
Painting GI Pipes and Fittings with two coats of anticorrosive bitumastic paint of approved quality
40 mm dia. nominal bore
50 mm dia. nominal bore
Making connection of G.l. distribution branch with G.l. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete ( Make - Fabricated at Site )
25 to 40 mm nominal bore
50 to 80 mm nominal bore
Providing & fixing ball valve ( brass) of approved quality,High or low pressure, with plastic floats complete:- ( Make - AIP / ZOLOTO / BELIMO )25 mm dia nominal bore
Providing and fixing ferrul with c.i mouth cover ( Make - Tata / Jindal Hissar / Jindal Ghaziabad )20 mm dia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : ( Make - As per approved local manufacturer )
15 mm diameter pipe
20 mm diameter pipe
25 mm diameter pipe
32 mm diameter pipe
40 mm diameter pipe
50 mm diameter pipe
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work)
25 mm nominal bore
50 mm nominal bore
Providing and fixing Thermoflex or Careflex thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification. ( Make - Kaiflex / Careflex / Armaflex ) 9 mm thick ( Pipes in Chases)
For 15 mm dia Pipe
For 20 mm dia Pipe
For 25 mm dia Pipe
For 32 mm dia Pipe
For 40 mm dia Pipe
Providing and fixing Thermoflex or Careflex thermal insulation tubing, a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification. ( Make - Kaiflex / Careflex / Armaflex )19 mm thick ( Exposed in Shafts & Terrace )
For 20 mm dia Pipe
For 25 mm dia Pipe
For 32 mm dia Pipe
For 40 mm dia Pipe
For 50 mm dia Pipe
For 65 mm dia Pipe
For 80 mm dia Pipe
For 100 mm dia Pipe
Providing and fixing C.I. butterfly valves PN-1.6 complete with bolts, nuts, 1.5 mm thick compressed asbestos gasket and flanges as per Table “E” complete . ( Make – NVR / AIP / Zoloto ) 65 mm dia
Providing, fixing, testing and commissioning of motorised butterfly valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in iverhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 2 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc. (Make: AIP / Zoloto / Belimo )
40 mm dia NB Float Valve
50 mm dia NB Float Valve
Providing and Fixing full way lever operated forged brass ball valve of brass body with forged brass hard chromeplated steel ball tasted to a pressure not less than 15 kg/sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. ( Make – NVR/ AIP / Zoloto )
15 mm dia
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
Providing and fixing M.S. puddle flanges fabricated out of 5 mm thick M.S. plate of size 200 x 200mm plus dia of pipe of 750 mm long pipe pieces to R.C.C. water tanks / R.C.C. walls. The entire fitting shall be hot dipped galvanised. ( Make - Fabricated at site )
25mm dia
50mm dia
65mm dia
80mm dia
100mm dia
150mm dia
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1cement :4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) including necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design. With common burnt clay (non modular) bricks of class designation 7.5
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design: (Make - Fabricated at site ) With F.P.S. bricks crushed
Supply, installation, testing & commissioning of Solar Water Heating System of 1 NOS ISI Marked Solar Flat Plate Collectors of size 2080mm X 1070mm X 100mm,, Laser welded . with necessary Stands, Support etc. with 100 Ltrs capacity SS -304 hot water storage tank of thickness 0.8 mm duly insulated with 50 mm thick PUFF insulation & 24 SWG Aluminium Cladding, with Heat Exchanger of suitable surface area, with necessary makeup tank, with 1 KWH Electrical backup for cloudy / foggy days, with necessary piping with solar panels & solar hot water tank, with one No. temperature Gauge, with 01 Nos. Ball valves, to produced hot water up to 60 degree C on clear sunny days. (MNRE Approved) ( Make - MAK V / Netsol Water Solution / Grey Water Solution )
CIRCUIT CUM POINT WIRING-Primary point controlled by one MCB.
CIRCUIT CUM POINT WIRING -Secondary point. i.e. Points to be looped with Primary point.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4x 1.5 sqmm+ 2x 1.5 sqmm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 10/25 amps modular socket outlet and 10/25amps modular Type MCB, connection etc. as required.
Supplying and fixing 12 way,Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
SITC of 1x12W(Nominal) Surface Mounted LED circular Downlighter(Cat no- Bajaj Lighting BGSLO 12W WH RD or equivalent as specified in the approved list of make.)
SITC of 15W(Nominal)Surface Mounted LED square Downlighter (Cat no- Bajaj Lighting BGSLO Sleek Surface 15 W WH SQ or equivalent as specified in the approved list of make.)
SITC of 15 W (Nominal) Bracket Light (Bajaj make BJLF2 15W RF or equivalent as specified in the approved list of make).
SITC of 1x18W(Nominal) Wall/Surface mouted LED (Cat no- BLRB-DB118 or equivalent as specified in the approved list of make.) Tubelight
SITC of 5W (Nominal) MIRROR LIGHT (Cat no-BCLSB 05 WH or equivalent as specified in the approved list of make.)
SITC of 10 W(Nominal) Bulk head Light (Cat no-BIBWP 10 W LED or equivalent as specified in the approved list of make.)
1200mm sweep 3 blade energy saving Ceiling fan complete with assembling of blades, down rod, shackle insulator, canopy etc.
Exhaust fan with louver and with 3 core flexible wire of GEC/ Newtek make.300 mm dia Domestic Exhaust Fan
Intelligent Addressable Manual call points Double Action Stations suitable for wall/column mounting. (UL, ULC listed & CSFM, MEA, FM approved)
Addressable Hooter cum strobe as per specifications to meet the function as , "Audible notification appliances should be silenced at ACK of alarm while the visible notification appliances are kept activated until the alarm condition is reset. Sounder will be 24 V DC input will give 80 db output at 3m and strobe with 110 candela output. (UL, ULC listed & CSFM, MEA, FM approved)
SITC of CAT 5 cable complete with termination and testing as per requirement.
BRE Global certified 2c x 1.5 sq.mm Fire Survival armoured cable with Class-2 Copper conductor as per BS EN 60228, twisted, with Mineral ceramic glass fire barrier tape covered by an extruded layer of Cross-linkable Low smoke zero halogen (LSZH) insulation as per BS EN 50363 and LSZH inner & outer sheath as per BS:7846. Should retain Circuit integrity as per clause 26.2e of BS: 5839-1. BRE Global & LPCB-FPC certificates to be provided. Outer sheath should be Anti-Rodent.
Supply, fixing, testing & commisssioning of Modular RJ-45 with data outlet socket with grid & cover plate in suitable size of 16 SWG GI box.
Supply, installation, testing and commissioning of 12 port jack panel- Category 6 IDC patch panel prepackaged with wiring block with legs insert labels, label holders, jumper troughs, metal back panel, duct assembly, screws, washers and an instruction sheet for termination of incoming pairs. Quoted price shall include suitable lockable enclosure etc. as required.
Supply & instalation of 6U rack- Rittal/ Comrack/ Dynamic
Supply & instalation of CAT6 UTP patch panel UnLoaded-Copper cables terminating within the floor distributor shall be terminated onto patch panels with RJ45 presentation, by means of an insulation displacement connector. The Patch Panel jacks shall be shuttered to prevent the ingress of dust and other contaminants.
Supply & instalation of Cat6 UTP XL Keystone connector
Supply & instalation of CAT6 UTP PATCH CORD 1M - Rack end- The work area equipment cords shall, at a minimum Comply with ANSI/TIA/EIA-568-C.2 Commercial Building Cabling Standards Transmission Performance Specifications for 4 pair 100 Ohm Category 6 Cabling. Category 6 equipment should be industry standard patch cords: • Shall be round, and consist of eight insulated 24 AWG, stranded copper conductors, arranged in four colour-coded twisted-pairs. • Equipped with modular 8-position modular plugs on both ends, wired straight through with standards compliant wiring. • Should have 50 micro inches of gold plating over nickel contacts. • Modular cords should include a moulded strain relief boot.
Supply & instalation of CAT6 UTP PATCH CORD 2M - User end- The work area equipment cords shall, at a minimum Comply with ANSI/TIA/EIA-568-C.2 Commercial Building Cabling Standards Transmission Performance Specifications for 4 pair 100 Ohm Category 6 Cabling. Category 6 equipment should be industry standard patch cords: • Shall be round, and consist of eight insulated 24 AWG, stranded copper conductors, arranged in four colour-coded twisted-pairs. • Equipped with modular 8-position modular plugs on both ends, wired straight through with standards compliant wiring. • Should have 50 micro inches of gold plating over nickel contacts. • Modular cords should include a moulded strain relief boot.
Supply & instalation of dual Port Face Plate- • Modular Single Gang square (86mm x 86 mm) with 2 ports • Screw hole covers • Should be able to support variety of jacks – UTP, ScTP, FTP etc. • Should facilitate entry for shuttered jacks / information outlets • Two modules or a single module and a blank may be installed in this format. • All outlets shall have facilities for labelling on either the face plate or module. This should be protected by means of clear plastic window.
Supply & instalation of Metal Flush Box - 1/2 module
Supply & instalation of 6 core Indoor/outdoor OM3 Unarmoured Multimode Optical Fiber
Supply, installation, testing and commissioning of 10 pair Tag block krone type tag blocks enclosed in MS enclosure of suitable size with lockable cover.
Supply, laying, testing and commissioning of 10 pair Ar. Cable size of 0.61mm dia copper conductor multi pair telephone cable as per suitable for indoor telephone wiring conforming for ITD S/WS - 113 C and S/WS - 114 (actual qty. may vary as per site) in existing conduit/ trench/ tray.
Supply & instalation of CAT6 UTP patch panel UnLoaded
Supply & instalation of Cat6 UTP XL Keystone connector
Supply & instalation of CAT6 UTP PATCH CORD 1M
Supply & instalation of single corded phone with caller ID & hands free phone with rechargable battery, auto redial with 20 redial memory, 20 one touch & 10 speed dialer, ringer indication, progammable flash time setting, programmable tone & pulse setting, three steps ringer volume & dial lock.
Telephone instruments- Caller ID, 3 display lines, Speaker Phone, Ringer LED,Dedicated Button for (Redial, Mute, Flash), alphanumerical keypad, Redial Memory- 20 redial, Phonebook Entries- 50Nos.(Model- Panasonic Kxts-880 Corded Landline Phone or equivalent as per specified approved list of make.)
Supplying,Receiving, fixing, testing & commissioning of LT PANEL Make-RISHA Control Engineers Pvt. ltd.,Krypton, PSG Electricals Pvt. Ltd.& ADELEC MDB (Lighting & Power panel ) INCOMER - 1 Nos. 200A TPN MCCB,25 kA breaking capacity with thermal release and adjustable setting and with rotary handle. METERING & INDICATION-1 set of R,Y,B phase indicating lamps,1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB,1 No. (0-200A) Ammeter with ASS with 3 nos. 200/5A CT's BUS-BAR-1 Set of 250A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS-2 Nos. 125A TPN MCCB,16 kA breaking capacity with thermal release & adjustable setting & with rotary handle, 1 No. 100A TPN MCCB, 16 kA breaking capacity with thermal release & adjustable setting & with rotary handle,2 Nos. 63A TPN MCCB, 16 kA breaking capacity with thermal release & adjustable setting & with rotary handle,3 Nos. 63A TPN MCB, 3 Nos. 40A TPN MCB
Supplying,Receiving, fixing, testing & commissioning of Lift Panel INCOMER-1 No. 63 A FP MCCB, 16 kA breaking capacity with thermal release and adjustable setting and with rotary handle.METERING & INDICATION-1 set of R,Y,B phase indicating lamps,1 No. (0-500V) Voltmeter with Built-in VSS with 3 nos. 2A SP MCB,1 No. (0-63A) Ammeter with ASS with 3 nos.63/5A CT'sBUS-BAR-1 Set of 100A TPN Aluminium Bus Bar with colour coded PVC Sleeves OUTGOINGS-3 Nos. 40A TPN MCB, 10 KA. C Curve, 1 Nos.63A SPN MCB, 10 KA. C Curve, 1 Nos.40A SPN MCB, 10 KA. C Curve.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with modular switch modular plate suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required. Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class conduit with 2 way modular switch modular plate suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc.as required.
Wiring for light/power plug points with 2 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light / power plug points with 4 x 4 sq.mm. FRLS PVC insulated, Cu. Conductor, single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq.mm. FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required
4x 10 sqmm+ 2x 6 sqmm earth wire
4x 16 sqmm+ 2x 6 sqmm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2x 1.5 sqmm+ 1x 1.5 sqmm earth wire
2x 2.5 sqmm+ 1x 2.5 sqmm earth wire
2x 6 sqmm+ 1x 6 sqmm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
4x 10 sqmm+ 2x 6 sqmm earth wire
4x 16 sqmm+ 2x 6 sqmm earth wire
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required25mm
Supply & fixing of following sizes of medium class PVC conduit along with accessories in surface / recessed including cutting the wall & making good the same in case of recessed conduit as required.
25 mm dia.
32 mm dia.
Supplying and fixing of following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Supplying and fixing of Stepped type 2 module electronic fan regulator on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing of following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
1or 2 module (75mmx 75mm)
3 module (100mmx 75mm)
4 module (125mmx 75mm)
6 module (200mmx 75mm)
Telephone socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 Amp modular socket outlet and 15/16 A modular switch, connection etc. as required.
Supplying & fixing of 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing
Providing and fixing following rating and breaking capacity and pole MCCBwith thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 Amp, 16 KA,TP MCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way, double door
12 way, double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
6 way (4+18),Double door
8 way (4+24),Double door
Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way Double door
Supplying & fixing 5 amps to 32 amps rating 240/415 volts C curve Miniature Circuit Breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Single Pole Neutral
Double Pole
Triple Pole
Supply & fixing of single pole blanking plate in the existing MCB DB complete etc. as required
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing of following rating four pole 415 V isolator in the existing MCB DB complete with connections ,testing and commissioning etc as required.
Supplying & Fixing of following rating double pole (single phase and neutral) 240 volts, Residual Current Circuit Breaker (RCCB), having a sensitivity current upto 300 milli-amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let andcomplete with connections, testing and commissioning etc. as required.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
Earthing with G.I. earth Plate 600mm x 600mm x 6mm thick including accesssories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal or coke and salt ) as required.(For Body earthing of euipments )
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
MOHD SALEEM
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.68 MB
BOQ_361488.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .