Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 1027 SECTOR 21B CHANDIGARH 160022 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160022 | ₹1.1 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹1.1 Cr+₹2.2 L (1.98%)Rejected-AOC 96 SECTOR 16 A CHANDIGARH 160015 | CHANDIGARH | CHANDIGARH | 160015 | ₹1.1 Cr+₹2.2 L (1.98%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.3 Cr+₹15.0 L (13.4%)Rejected-AOC | ₹1.3 Cr+₹15.0 L (13.4%) | L3 | Rejected-AOC L3 |
| 4 | L4₹1.6 Cr+₹45.9 L (40.9%)Rejected-AOC | ₹1.6 Cr+₹45.9 L (40.9%) | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
13 Nov 2021, 6:00 pmClosed
CWE(AF) Tughlakabad
HQ CWE(AF) Tughlakabad
IMPROVEMENT TO INFRASTRUCTURE AT MECHINE SHOP IN ENGINE DIVISION AT 3BRD, AF (PHASE-I) UNDER GE (AF) MC CHANDIGARH
2021_MES_473578_2
CA NO. CWE/TKD/CHD/TOKEN-32/2021-22
Open Tender
Civil Works
Works
270 days
GE (AF) MC CHANDIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE (AF) MC CHANDIGARH
₹2.0 L
Yes
16 Dec 2021
23 Oct 2021
15 Nov 2021
23 Oct 2021
13 Nov 2021
30 Oct 2021
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
M & L for PCC 1:4:8 type D-2 using 40mm graded aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in coping etc including necessary form work, weathering slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:4 on stone masonry external surfaces finished fair and even without using extra cement complete all as specified and directed.
M & L for preparation of newly plastrered surfaces of walls & applying two coats of cement base paint incl alkali resistant priming paint, complete all as specified and directed.
M&L for reinforced cement concrete 1:1.5:3, type B1 using 20 mm graded stone aggregate as in slabs, coloumns, beams, lintel beam etc supported on walls/beams and shelves columns etc.complete all as specified and directed.
M&L for formwork to sides of concrete slab, foundations, footings, bases of columns, raft and beams, sides and soffits (if any) of foundation and plinth beams , and similar work, vertical or to batter, flat surfaces of concrete , surface is required to be fair finished complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads breaks in floors windows cills concrete railing opening in concrete walls floor etc surface is required to be fair finished complete all as specified and directed.
M&L for 10 mm dia and over mild steel TMT bars as in reinforcement , cut to length, bent to shape required, incl cranking and binding with MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for 6 to 8 mm dia mild steel TMT bars as in reinforcement , cut to length, bent to shape required, incl cranking and binding with MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for powder coated aluminum frame /shutter of any type for doors,windows,ventilators,partitions with one or more rebates including joining cleat for fixing complete all as specified and directed.
S&F pre-laminated water proof particle board 12mm thick, interior grade, pre laminated both side decorative as approved ,fixed in frames complete all as specified and directed.
S&F sheet glass, 5.00 mm thick ordinary and glazing with aluminum beadings/ oil putty etc as required at site exc 0.5 sqm in each pane complete all as specified and directed.
S&F 125mm size aluminum anodized butt hinges complete all as specified and directed.
S&F 150mm size extruded aluminum alloy handles, fabricated type , anodized complete all as specified and directed.
S&F aluminum anodized barrel bolt of extruded section 300 mm long complete all as specified and directed.
S&F mild steel Mortice lock verticle type 100mm size, 6 lever fixed in aluminium shutter complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut Kota stone slab flooring 18-20mm thick , size of stone not less than 550 x 550 mm over & incl. 15mm thick screed bed or bedding layer in cement mortar 1:6 as in floor laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab incl. rubbing with mirror polish complete all as specified and directed.
M&L for kota stone slab 18- 20mm thick as in riser of steps, skirting, dado, riser of stair cases and pillar laid over 10mm cement rendering in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing & incl necessary bull nosing complete all as specified and as directed.
S&F for steel rolling shutters, thickness of laths 1.25mm with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated complete with gear operated type with bevel gear box and crank handle complete all as specified and directed.
S&F mild steel work as in roof trusses(frame), trussed, purlins, crane, gantries, rail, cleat framing (beam ,tee, angle,channel,flat section including welding etc.conforming to Fe-410-W (gde-E-250) quality A complete all as specified and directed.
M&L for preparation of old plastered surfaces by complete removal of existing treatment and applying two coats oil bound distemper, white or tinted over a coat of alkaline resistent primer over and including a layer of 2 mm thick wall care putty on the existing surface, at any height including necessary scaffolding etc complete all as specified and as directed
Supply, installing, testing and commissioning of Indoor type step down transformer of capacity 11000/433 volts (at no load), AC, 3 phase 50 Hz capacity 250 KVA core type copper wound, oil immersed, naturally cooled, oil nature, air nature (ONAN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector symbol DYN – 11 (vector Group) with neutral brought out on secondary side (LV side ) and having tapping at + 5% HV side to be changed by means of hand operated off load tap changer gear as per IS 1180:2014. The maximum temperature rise should not exceed 45 degree Celsius in oil and 55 degree Celsius in HV/LV winding when measured by resistance method (Necessary test certificate carried out at factory site to be produced) after continuous full load run on an ambient temp of 40 degree Celsius. The transformer shall be IS 2026 marked and shall comprise of the following :- '(a) 3 Nos porcelain bushing with arcing horn on HV side suitable for 11 KV complete with bushing, copper rods, nut and washers (b) One cable box both side on HT/LT side (primary of secondary side) consisting of 03 Nos, 04 Nos of porcelain insulator simultaneously. (c ) Oil conservator with filter type drain valve and oil level gauge. (d) De-hydrating breather with first fills dehydrating agent (silica gel) (e) Explosive vent. (f) Thermometer pocket on tank cover (g) One No 100 mm dia, dial type thermometer, vapour pressure type having range 0-120 degree Celsius with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer (h) Two earthing terminal on tank cover to facilitate fixing of 32 x 6 mm galvanized iron earth strip for earthing of neutral and body. (j) Including first fill of new and unused transformer oil of dielectric strength 52 KV confirming to relevant IS. (k) Shut off valve between the conservator and bucholz relay. (l) Rating and diagram plate. (m) Lifting hooks. Note : The oil temperature and winding temperature gauges shall be on a MS Box made out of 16 gauge MS sheet. The MS Box made hinged door and having glass 3 mm thick front of the box provision for entry of cable and compression glands.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth and getting out in soft/ loose soil for laying GI pipe of dia 20 mm complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm in any type of soil complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Supply and filling dry clean sand in trenches for cushioning of underground cable including punning down complete all as specified and directed.
M & L Unreinforced precast concrete cable cover , class HVP, type 1 with peak size 300mmX180mmX40mm complete all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty with aluminuim conductor 11000 volts grade, cross area sectional 95 sqmm 3 core complete all as specified and directed.
S&F cable joint kit for 11 KV grade cable for indoor end termination Cold shrink type joint suitable for 3 core XLPE armoured aluminium cable of size 95 sqmm complete all as specified and directed.
S&F bricks using sub class B bricks ( old size) for Cable protection laid flat and dry in trenches over cable perpendicular to direction of cable complete all as specified and directed.
M&L for boring of hole under road, pavement, hard standing by trench less technology using ultrasound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
M&L for GI tubing 80 mm bore light grade for cable protection with all fittings complete all as specified and directed.
Supply and laying 240 Sqmm 3.5 core XLPE cable insulated armoured heavy duty electric cable with alumunium conductor 1100 volt grade complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode of 60 cmx60cm x 6 mm thick 2.25 deep below in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below ground level connected to GI strips of 32 x 6 mm thick by means of nuts bolt ( 4 Nos ) check nut, riveting washer including exacavation, PCC 1:3:6 type C-1 chamber with RCC cover (1:2:4) type BO, 40mm thick reinforced with 6mm dia bar, 3 Nos both bay, 32mm dia light grade GI protection pipe, funnel with wire mess, watering pipe of size 20mm dia medium grade lugs, main earthing lead upto 7.5 Mtr including , charcoal dust, salt etc all as shown in electrical plate No 3 of SSR Part-I
Supply, installation, testing and commissioning of 100 Kvar Company make Automatic power factor improvement system of 3-phase 415V, 50Hz, floor mounted, modular design structure, Non- compartmentalized, dust and vermin proof, made out of 3.15mm M.S Sheet and M.S Angle Iron 40 x 40 x 6mm frame, duly powder coated, front & back open able with locking arrangement to facilitate easy maintenance, heavy Cable entry gland provision, hooks on top for mounting panel in Platform. Complete Capacitor and Reactor Filter assembly should be mounted on the rack through nut & bolts so that it can be taken out from the panel, during the maintenance / replacement. Necessary internal connection with proper copper wire rating & lugs. Proper control wiring with protection to Relay, fans and Thyristor module comprises of following:-
MAKE: ABB/ L&T / NEPTUNE / EPCOS AXIAL FLOW FAN with thermostat on the Top with MCB Protection BUS-BARS - 200 amps TP Copper bus bars SMPS POWER SUPPLY: 24 V, 9A SMPS power Supply for TSM Firing with protection on incoming & Outgoing INCOMER : 200 Amp TP,MCCB, Thermal magnetic, adjustable with O/L & S/C protection, 100% Ics =Icu, 36 KA MAKE - L&T/GE/Legrand/ABB OUTGOING ( BANK PROTECTION) HRC Fuse sets for backup of Group - I - 3 Nos of 12A HRC Fuse Link in 32A Fuse base Group - II - 3 Nos of 25A HRC Fuse Links in 32A Fuse Base Group - III – 3 Nos of 25A HRC Fuse Links in 63A Fuse Base Group - IV –3 Nos of 32A HRC Fuse Links in 63A Fuse Base MAKE - L&T / GE / SIEMENS / ABB Glass fuse links 2A, with base for Thyrister module Protection MAKE – Connect well / FTC / Phoenix THYRISTOR MODULE – Electronic Thyristor Switching Module( Not SSR- solid state relay) should be capable of Voltage peak withstand capacity of upto 2200 V PIV. They should be installed in separate enclosure with heat sink , firing card and axial fan for its cooling operation Group - I - 2 Nos of 5Kvar Group - II - 1 Nos of 15Kvar Group - III – 1 Nos of 25 Kvar Group - IV –1 Nos of 50 Kvar
MAKE - L&T /GE / Neptune / Epcos CAPACITORS: Capacitor should be Super Heavy Duty( MDXL) with 525V, 50Hz capable of withstanding current up to 4xIn and temperature withstanding up to 70 deg C temperature on its surface without any detoriation in its lifespan Group - I - 2 Nos of 5Kvar Group - II - 1 Nos of 15Kvar Group - III – 1 Nos of 25 Kvar Group - IV –1 Nos of 50 Kvar MAKE - L&T /GE / Neptune-Ducati / Epcos
Supply, installation, testing and commissioning of air cooled standard floor standing inverter package air conditioners of 11TR capacity with ECO friendly refrigrent R-410a fitted with hermetically sealed inverter scroll compressor complete with stepless capacity control,all fittings , inbuilt electric control panel & microprocessor controls including lifting,shifting,nitrogen pressure testing & gas charging the indoors should be designed to deliver atleast 4400 CFM complete all as specified and directed. Make-Bluestar/Carrier/Daikin
Supply, installation, testing and commissioning of copper piping complete with all fittings such as bends, tees, elbows etc. including insulation as required of approved make complete all as specified and directed for the followings. 'Make-Totaline/Mandev/Mettube
Discharge Line 1 1/8 inch
Liquid Line 7/8 inch
Supply and installation of strip heaters arranged in banks of Cap (3x3KW) for each unit complete with control wiring, gyser stat, Humidistat and Heating thermostat for monsoon re Heating and Winter heating complete all as specified and directed for the followings. Make:- DASPASS
Supply, installation, testing and commissioning of drain water piping 25mm with PVC heavy duty pipes complete with all fittings such as bends, tees, elbows, flanges, pipe hangers, supports, anti-vibration hangersand insulation complete all as specified and directed for the followings. Make-Plasto/Supreme)
Supply, installation, testing and commissioning of GI ducting material as per technical specifications and drawings complete with all fitting, accessories, dampers, vanes, take offs, canvas connections transformation.The mouth piece of duct shall be made with 22G only. The rate shall include suspension and supporting arrangement with angle iron and dash fasteners of reqd size complete all as specified and directed for the followings.. (Make-TATA/SAIL) Note:- Drawing will be produced by the contractor before execution of work.
Supply, installation, testing and commissioning of Aluminium extruded powder coated grilles & diffusers with aluminium volume control dampers as per design complete all as specified and directed. Make : Dynamic/Ravi Star/Carryaire)
Supply, installation, testing and commissioning of fire retardant non porous double layer flexible connection between each indoor unit and duct complete all as specified and directed.
Supply, installation, testing and commissioning of acoustic lining rigid board Twiga 300 of duct work with 12 mm thick fiber glass(density 48kg/cum) stick using shalikote primer hot bitumen and mechanically fastened, covered with RP tissue and 30G aluminum perforated sheet complete all as specified and directed. Make : Armacell/K-Flex/Arma Flex .
Supply, installation, testing and commissioning of duct thermal insulation with 13 mm thick Nitrile rubber with black BOPP tape 75 mm wide complete all as specified and directed. Make : Armacell/K-Flex/Arma Flex.
M&L for MS frames with vibration pads for Indoor & Oudoor unit complete all as specified and directed.
S&F control wiring with copper conductor, PVC insulated, unsheathed multi stranded 1.5 sqmm 2 core drawn in and including PVC conduit medium duty copper cable for interlocking between IDU & ODU(considering main supply & TPN/MCCB with double earth Shall be provided by electrical contactor near each outdoor unit) complete all as specified and directed. Make-Havells/Polycab/Finolex
S&F control wiring with copper conductor, PVC insulated, unsheathed multi stranded six core of size 1.5 sqmm copper drawn in and including PVC conduit medium duty of suitable size for interlocking arrangement as per standard practice for thermostat, humidistat, heater bank etc required for satisfactory completion of the job complete all as specified and directed. Make-Havells/Polycab/Finolex
Supply,installation, testing and commissioning of copper cable 4Core × 10Sqmm armoured type for each package unit complete all as specified and directed. Make-Havells/Polycab/Finolex
M&L for earthing complete with galvanized steel earth plate electrode of 60 cmx60cm x 6 mm thick 2.25 deep below in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of plate not less than 1.5 m below ground level connected to GI strips of 32 x 6 mm thick by means of nuts bolt ( 4 Nos ) check nut, riveting washer including exacavation, PCC 1:3:6 type C-1 chamber with RCC cover (1:2:4) type BO, 40mm thick reinforced with 6mm dia bar, 3 Nos both bay, 32mm dia light grade GI protection pipe, funnel with wire mess, watering pipe of size 20mm dia medium grade lugs, main earthing lead upto 7.5 Mtr including , charcoal dust, salt etc all as shown in electrical plate No 3 of SSR Part-I complete all as specified and directed.
S&F 32mmX6mm GI strip on surface or in recess for connections etc. as required complete all as specified and directed.
Anil Kumar Gupta
shree balaji builders
ELECTRA ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .