CWA W S III
Okhla Sewage Treatment Plant, Mathura Road, Delhi 110020
NIT No. 07 2022 23 Item No.1
2022_DJB_227676_1
NIT No. 07 2022 23
Open Tender
Miscellaneous Goods
Works
45 days
Okhla Sewage Treatment Plant, Mathura Road
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Indian Bank
₹30,500
8 Sept 2022
12 Aug 2022
29 Aug 2022
12 Aug 2022
29 Aug 2022
12 Aug 2022
Specifications for BOD Incubator with PLC/microprocessor controlled and RFID magnetic lock Temperature Range: · BOD Incubator shall have temperature range of 20 to 40 degree C variable with increment of .1 degree C. · BOD Incubator shall have auto cuff off on heating and cooling temperature Material of construction: · BOD Incubator should have outer body Bacteria-resistant power coating and inner chamber with SS 304 mat finish, with double door facility. · Door should be 3, Dual-pane glass kit heater to avoid moisture. · Minimum of 60mm-80mm non- CFC foamed urethane insulation Design: · BOD Incubator shall have minimum 4 sleeves with anti-inclination function to avoid falling off when shelve is pulled out. Shelves should be made of Acrylic with high quality mesh to support bottles /tubes for routine day to day work. And can accommodate 18 to 20 bottles in a rack of 300-400ml bottles per shelve. · BOD Incubator shall have four caster wheels with two brakes /lock in front wheels. · BOD Incubator should triple door facility with RFID assisted magnetic lock system. · BOD Incubator shall have high, low and door alarm · BOD Incubator shall have large impeller fans, fast temperature rise and fall stable temperature control with good temperature uniformity. Battery Backup: · BOD Incubator shall have display battery back up for temperature display at the time of power failure. Capacity: · BOD Incubator shall have capacity 400 liters. Cooling Gas: · BOD Incubator should be CFC free Uniformity. Display and software: · BOD Incubator shall be PLC based controlled based system with touchscreen input and display. BOD Incubator shall be Microprocessor controlled operate · BOD Incubator shall have touch screen 7.4” to display real time display of parameters temperature, Time, Date, Password protected, Alarm on/off, USB / RS232 port for data transfer. · BOD Incubator have High/Low Alarm Door opening Alarm, Condenser heat alarm, compressor heat alarm, sensor failure alarm, Process complete alarm, power failure alarm. · BOD Incubator should have Temperature Graph in display. · BOD Incubator should have Min-Max feature enabling users to view the minimum and maximum-recorded temperatures on the home screen. This makes it easier to document the minimum and maximum temperatures important at the time of storage any item. · On unlocking/Opening of the incubator it shall record the name of official unlocked/opened the door. · Log of all data and record shall be recorded and can be downloaded. Data Log/ Memory: · Memory storage capacity should be up to 50000 logs with USB transfer in pdf and excel/csv format. Locking Mechanism: · Locking/unlocking through RFID card or by password with touchscreen display. Includes USB port for data retrieval. Warranty: · 3 years Certification: Manufacturer should be USFDA/IEC/150 certified Make : Krish, HV Biomedical, Helmer and Viomatra.
Beyond
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .