Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAccepted-AOC | L1 | Accepted-AOC ok |
Tender Value
₹1.5 L
EMD Value
₹3,040
Closing Date
27 Apr 2021, 3:00 pmClosed
Anil Narwal
EXECUTIVE ENGINEER PROV DIV NO 4 PWD B AND R PGIMS ROHTAK
Reinvited for Dismantling and reconstruction of ATM Kiosk near the wall of Pt Neki Ram College in Admn Block premises in Pt BDS UHS Rohtak
2021_HRY_169301_1
PWD/P4/569
Open Tender
Civil Works
Works
120 days
PGIMS Rohtak
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹3,040
Yes
1 May 2023
19 Apr 2021
27 Apr 2021
19 Apr 2021
27 Apr 2021
19 Apr 2021
Amount
Earth work in excavation in foundations, trenches, etc. in all kinds of soils, not exceeding 2 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil, clear from the edge of excavation and subsequent filling around masonry, in 15 cm layers with compaction, including disposal of all surplus soil, as directed within a lead of 30 meters. (HSR 6.6)
Dismantling Brick Work, Tile Masonry or Tile lining and Tile Terracing. (b) In cement (HSR 8.5 b)
Dismantling Roofing. (h) removing R.C.C. battens from roof.(HSR 8.8)
Removing rolling shutters including top cover, brackets and side guides etc. complete. (HSR 8.24)
Dismantling cement conglomerate /terrazzo floors 25 mm to 50 mm thick including concrete base (HSR 8.25)
Cement concrete 1:8:16 with brick ballast 40 mm Nominal size in foundation and plinth.(HSR 10.26)
Cement concrete 1:1-1/2:3 with stone aggregate 20 mm nominal size for reinforced concrete work in shelves excluding steel reinforcement, but including centering and shuttering ,laid in position ,complete in all respects. (HSR.10.81+10.95,a)
Damp proof course 40 mm thick of cement concrete 1:2:4 using stone aggregate with two coats of bitumen 20/30 penetration at 1.65 Kg. per sqm laid hot and sanded.(HSR 10.114)
First class brick work laid in cement sand mortar 1:6 in foundation and plinth(HSR.11.2)
First class brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level (HSR.11.7)
11.43 cm thick brick wall laid in cement sand mortar 1:4 in superstructure(HSR.11.48 a)
Terracing consisting of tiles 22.86 cm X 11.43 cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25mm mud plaster and another layer of mud mortar for laying the tiles , including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc.(HSR.13.13)
Cement concrete 1:2:4 gola 10cm X 10 cm quadrant along junction of roof with parapet wall finished smooth ,where specially specified.(HSR.13.64)
Providing and fixing PVC rain water pipe 6kg pressure of ISI mark in cement mortar during masonry work.(HSR 13.89)
(a) 100 mm dia PVC pipe 6 kg . Presure
Providing & fixing PVC bend ISI mark(HSR 13.90)
(a) 100 mm dia PVC bend
Providing & fixing tiled false ceiling of approved materials of size 595x595mm in true horizontal level, suspended on inter locng metal grid of hot dipped galvanized steel sections (galvnized @ 120 grams/sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600mm and secondary cross "T" of length 600mm an size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panl to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fitting, fixtures, smoke detectors etc. main "T" runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4mm GI djustable rods with galvanised butterfly level clips of size 85x30x0.8mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights paints, all complete for heights as per specifications, drawings and as directed by Engineer-in-charge.(HSR 13.98)
(a) GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm,and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
Base course of floors consisting of 100 mm thick cement concrete 1:8:16 and 100 mm sand or stone filling(HSR.14.1)
Screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping.(HSR.14.4)
Conglomerate floor 40 mm thick cement concrete topping 1:2:4.(HSR.14.9)
Laying and fixing vitrified/ceramic anti skid tiles of any size of approved make in floor laid in any pattern as specified over a base of 20 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. (Tiles shall be supplied by the Department). (HSR 14.93)
Laying and fixing vitrified/ceramic/glazed tiles of any size of approved make in skirting/dado, pillars, wall facing, laid in any pattern as specified over base of 12 mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles. (Tiles shall be supplied by the Department). (HSR 14.94)
12 mm thick cement plaster 1:4 on walls (HSR 15.5)
15m thick cement plaster 1:4 on the rough side of single or half brick wall ( HSR 15.10).
10 mm thick cement plaster 1:4 under side of ceiling (HSR 15.52)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 16.3) L.R
Applying priming coat with metal primer on new steel or iron work including preparation of surface. (HSR 16.9) L.R
Distempering with washable oil bound distemper (of approved manufacture) two coats excluding priming coat on new work. (HSR 16.57) L.R
Providing two coats of exterior acrylic emulsion paint. ( HSR 16.79) L.R
(b) 1st quality
Providing and applying two coats white cement based putty over plastered surface and grinding the surface smooth with sand paper to get an even and smooth finish including cost and carriage of all material labour charges scaffolding sundries etc. complete (J.K/Birla make)(HSR 16.81)
Cost of aluminium fittings complete for doors and windows, such as tower, bolts, handles, etc. and screws for these fittings (excluding sliding bolt) (HSR 17.72) (a) For single leaf shutter
Supplying and fixing hydraulic door closer ISI mark with necessary screws etc. complete ( HSR 17.82) ( c ) I.S.I designation no.III (size of door 851mm to 1000 mm).
Providing and fixing sliding bolts with nuts and screws, etc., complete (HSR 17.83) (b) Aluminium (ii) Size 250mmx16mm
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to I.S.733 and I.S. 1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fasterners including necessary filling up of gaps at junction, at top, bottom and sides with required neoprene felt etc. aluminium sections shall be smooth, rust free straight mitred and jointed mechanically wherever required including cleat angle. Aluminium snap beading for glazing/panclling C.P. brass/stainless steel screws, all complete.Fixed portion (Anodised aluminium transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15)(HSR 17.95)
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to I.S.733 and I.S. 1285 fixed with rawlplugs and screws or with fixing clips or with expansion hold fasterners including necessary filling up of gaps at junction, at top, bottom and sides with required neoprene felt etc. aluminium sections shall be smooth, rust free straight mitred and jointed mechanically wherever required including cleat angle. Aluminium snap beading for glazing/panclling C.P. brass/stainless steel screws, all complete. Shutters of doors , window & ventillators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required including aluminium fitting(HSR 17.96)
Providing and fixing glazing in aluminium door windows, ventilator shutter and partitions etc. with pvc/neoprene gasket etc. complete (cost of aluminium snap beading shall be paid in basic items). (HSR.17.98) (b) With float glass panes of 5.0mm thickness.
Supplying and fixing rolling shutters of approved make, M.S. Laths, interlocked together through their entire length, and jointed together, at the end, by end locks mounted on specially designed pipe shaft with brackets, side guides, 27.5 cm long wire spring grade no.2 and arrangement for inside and out-side locking, with push and pull operation complete, including top cover 0.80 mm thick (payment is to be made for the exact size of opening where rolling shutter is fixed) : - (b) with 80mm x 1.25mm M.S. Laths (HSR 18.18 b)
Steel reinforcement TMT bars FE-500 EQR / FE-500 D grade or more for RCC work, where no included in the complete rate of RCC including straightening, bending, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. and placing in position complete in all respects for all heights/depths/storeys/basements etc. (HSR 18.22). Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work, excluding overlaps. From the length so measured, the weight of reinforcement shall be calculated in tones on the basis of IS:1732.Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods for binding and placing, shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
N.S ITEM
Dismantling of falses ceiling & cutting of old battens and removing MS patti complete in all respect.(N.S)
N.S Recovery items Civil work
Bidders have to quote rates for recovery items at least or more than reserve price. The rates quoted against recovery items will not be included in the total amount, rather it will be deducted while calculating financial statement of the agency.
Collection of bricks received after dismantling of brick and tiles work (N.S) The reserve price of the dismantled material is as under:- @ Rs. 3.00/- each.
Collection of brick bats received after dismantling of brick and tiles work (N.S) The reserve price of the dismantled material is as under:- @ Rs. 400/- per cum.
Removing of rolling shutter complete.(N.S) The reserve price of the dismantled material is as under:- @ Rs. 500/- each.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .