Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39,776.53Accepted-Finance GOVT CONTRACTOR TEYLERABAD SRI VIJAYA PURAM PIN 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | ₹39,776.53 | L1 | Accepted-Finance First Lowest |
Tender Value
₹44,743
Closing Date
4 Sept 2026, 10:00 amClosed
Executive Engineer
EE,EandM, Division, APWD, Prothrapur
Construction of Staff Toilet at Veterinary Dispensary Manglutan under EandM Division APWD, Prothrapur SW Providing IEI
2026_APWD_24480_1
DB-WO/EandM/DIV/PP/26-27/2013
Open Tender
Electrical Works
Percentage
20 days
South Andaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
4 Sept 2026
29 Aug 2026
4 Sept 2026
29 Aug 2026
4 Sept 2026
1 Sept 2026
29 Aug 2026 - 1 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
a) Group C | 14 | Point | 1,401 | ₹19,614 |
| 2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 25 | Mtr. | 290 | ₹7,250 |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 12 | Mtr. | 212 | ₹2,544 |
| 4 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. | 8 | Each | 94 | ₹752 |
| 5 | Supplying and fixing brass batten/ angle holder including connection etc. as required. | 6 | Each | 170 | ₹1,020 |
| 6 | Supplying of LED 9W Bulb in the existing Batten Holder similar to Phillips, Cat No. ACE Saver 2 Star or equivalent etc as required | 6 | Each | 173 | ₹1,038 |
| 7 | Supplying, Installation, Testing and Commissioning of 1 x 4' CRCA Housing Box Type luminaries suitable for T8 LED Tube (1 x 18 / 20W) Similar to Bajaj Model No. BLRB-DB 118 or equivalent etc as required | 5 | Each | 737 | ₹3,685 |
| 8 | Supplying of 20W LED Tube Light with Polycarbonate housing designed for high performance similar to Bajaj Model No. BLRB 20W LED or equivalent etc as required | 5 | Each | 944 | ₹4,720 |
| 9 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) Single Pole | 2 | Each | 289 | ₹578 |
| 10 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
a) 40 A | 1 | Each | 491 | ₹491 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.98 MB
TermsandCondition.pdf
Other Documents • 0.40 MB
BOQ_25918.xls
BOQ • 0.34 MB
Instructions-to-bidders.pdf
Additional Documents • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .