Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹27.7 L+₹3.1 L (12.4%)Rejected-Finance | L2 | Rejected-Finance Other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
6 Mar 2024, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE(AF)EM CHAKERI KANPUR
REPAIR/ MAINT OF VOLTAGE STABLIZER AND DEVELOPMENT OF BORE WELL AND CONNECTED ALLED WORK AT AFS CHAKERI KANPUR
2024_MES_640562_1
8692/E8
Open Tender
Civil Works
Item Rate
180 days
Area under GE(AF) EM Chakeri
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹500
GE (AF) E/M CHAKERI
₹50,000
Yes
13 Jun 2024
3 Feb 2024
11 Mar 2024
5 Feb 2024
6 Mar 2024
17 Feb 2024
Amount
M&L for pouring of Sodium Meta Hexa Phosphate in the borewell complete all as specified and directed.
M&L for lifting out submersible pumps set from bore well with column pipe steel rope, submersible cable including commissioning testing the same after developing the borewell complete all as specified and directed.
M&L for development of bore well by Air Compressor capable to work at pressure gauge approx 300 to 500 PSI and capacity approx 1000 cfm to clean the slots of the pipe and to explore the possiblity of recouping of well with natural water table including transportation, errection and dismantling of air compressor complete all as specified and directed.
M&L for development of bore well by over pumping for 48 hours to clean the slots of the pipe and to explore the possiblity of recouping of well with natural water table including transportation, errection and dismantling of air compressor complete all as specified and directed.
All as per item No. 4.00 above but for 24 hrs if required on the basis of out put results complete all as specified and directed. Note for item No 3.00, 4.00 & 5.00: Log sheet of compressor machine shall be maintained and signed by Contractor, JE, Engineer-in-Charge and GE.
M&L for testing of yield of well by means of 'V' notch, necessary T&P and equipments complete all as specified and directed.
Running of developed bore for 16 Hrs continous to check the potability of water after and including lowering the pump set of desired capacity complete all as specified and directed.
Supply & filling pea gravel for packing of size 3 to 5 mm to be designed by the contractor of natural shape brought direct from river bed and packing around the casing and slotted pipe in deep borewell all as directed by Engineer in Charge. Note: Qty of Pea gravel as braught by the contractor shall be 1st recorded in MB and after pouring remaining qty of Pea gravel shall be recorded in MB and there after difference in qty of Pea gravel shall be measured for pouring of pea gravel.
S&F discharge head assembly 150 mm dia incl PCC 1:2:4 type B1 using 20 mm graded stone aggregate for and with provn of bolts for foundation etc complete all as specified and directed
S&F in replacement MS nut bolt with washer of any size complete all as specified and directed.
S&F in replacement rubber packing flange 80 mm dia complete all as specified and directed.
S&F in replacement of rubber packing flange 100 mm dia complete all as specified and directed.
S&F in replacement of rubber packing flange 150 mm dia complete all as specified and directed.
M&L for providing water proof joint for submersible cable any size complete all as specified and directed.
S&F in replacement of electric cable submersible type flat 3 core 16 Sqmm stranded copper conductor PVC sheathed complete all as specified and directed.
All as per item No 15.00 above above but size 10 Sqmm 3 core. Note : For Item No 15 & 16 Old cable shall be deposited to MES store and taken on charge.
Supply & lowering in replacement MS column pipe 150mm dia in standard length of 3.00 m, heavy grade as per IS:1239 ERW pipe, duly threaded at ends with provision of MS flange duly drilled and welded, supported with 4 nos welded MS flat strips at each flange of cross section 40 mm x 5 mm thick complete all as specified and directed. Make: JINDAL / TATA / PRAKASH SURYA
All as per item No. 17.00 above but 100 mm dia.
All as per item No. 17.00 above but 80 mm dia.
M&L for clamps and bore covers from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Testing of drinking water (chemical analysis) as per IS : 10500 from authorised / approved lab after taking the sample from Pump houses in steralised container as per guideline of medical authority complete all as specified and directed. Make of Lab - All india institute of hygiene and public health / Govt. Lab Notes: If contractor do not submit the testing report within one week after testing is completed as per norms a penalty of Rs 1000/- per day for delay in submission of report will be levied on the contractor.
S&F in replacement fully automatic star delta starter, suitable for 50 HP motor, for submerssible pump set including connecting all incoming and outgoing copper wire complete all as specified and directed. Make: L&T Cat Part No MU-G 50 L&T / ABB / Legrand / Schneider
S&F in replacement fully automatic star delta starter, suitable for 30 HP motor, for submerssible pump set including connecting all incoming and outgoing copper wire complete all as specified and directed. Make: L&T Cat Part No MU-G 30 / ABB / Legrand / Schneider
Supply, installation, commissioning and testing submersible pump set of capacity 40 HP at up to 105 Rm, 1200-1400LPM, head inside the bore well comprising of SS impellors in CI casing with stainless steel shaft, leaded bronze bearing / bushes stainless steel shaft, sleeve complete all as per IS 8034 of 1989 complete with submersible motor AC 3 phase, 50 Hz, 380 to 440 Volt of 40 HP stainless steel tubing as per IS complete all as specified and directed. Note: Old unserviceable pump set will be deposited by the contractor in E/M store yard and shall be taken on charge.
S&F in replacement pressure gauge size 100 mm dia round, range 0-10 Kg/cm2 complete with air cock for 15 mm dia GI pipe complete all as specified and directed. Make: H guru / Japson / Fiebig
S&F in replacement sluice valves 150 mm dia class PN-1.0, IS-14846 with flanged ends, stainless steel spindle and iron wheel including nut bolts and rubber packing omplete all as specified and directed. Make: Kirloskar / Upadhyay / GDPA / Kartar
Disconnecting AC supply, dismantling, taking down and opening 45 to 100 KVA, three phase, oil cooled Servo Voltage stabilizer and servicing, repair/replacement unserviceable parts such as contact bush, mechanical tap moving system, filtration of oil, topup new oil, servo motor, carbon busher assembly with carbon and repair/maint/replacement of PC board, indicator, transformer, harmonic filter etc and other minor parts found defective during repairing including re-assembling the same after repairing and commissioning, testing complete all as specified and directed.(SM/MES Number of Voltage stablizer considered for repair shall be entered in MB) NOTE:- (i) Replaced parts of voltage stabilizer will be measured and paid separetly under respective items of BOQ. (ii) New oil, filtration of oil will be measured & paid under respective items of BOQ. (ii) Minor parts such as Nuts, Bolts & washers, gasket, insulating material, PVC copper wire with connected items for circuit wiring etc deemed to include in quoted rate in this item.
Supply only following parts required for item No 27 above complete all as specified and directed.:- Push Button Note for item No 28 & 29 to 50: Taking down and fixing charges of the unserviceable items (28 & 29 to 50) is included in the quoted rate of Item No. 27.00 above. Nothing extra wiil be paid on this account.
Auto manual switch
Micro switch
Toggale switch
Indicator of different colour
Digital volt meter
Digital Amp meter with CT
Multifunctional meter
Trigger Transformer
Rotary Switch for R,Y, B phase
Breather with first fill silicagel
Carbon busher assembly with carbon suitable size & type or as per existing
Buckboost transformer of 45 to 100 KVA capacity, Make & type as per existing
PCB (printed circuit board) of suitable size & capacity or as per existing
PCB connector of suitable size & capacity or as per existing
Servo motor 3 Kg torque, Make & type as per existing
Servo motor 10 Kg torque, Make & type as per existing
RC network for 3 Kg Motor
RC network for 10 Kg Motor
Drive assembly upto 100 KVA per phase
Low cut switch suitable size & capacity or as per existing
High cut switch suitable size & capacity or as per existing
Dimmar (variable transformer) of 45 to 100 KVA capacity, Make & type as per existing
S&F in replacement of MCCB, 4 pole, 415 Volt grade, AC 160 amp 16kA microprocessor based complete all as specified and directed. Make: L&T / ABB / LEGRAND / SCHNEIDER
All as per item No 51.00 above but 75/80 Amp.
S&F in replacement of LT bushing complete with spindle, bushing washers, bushing rod (brass), metal part, gasket set, nuts, bolts and washers for 45 to 100 KVA capacity any type of stabilizer at site / in workshop complete all as specified and directed.
Rectifying and arresting the oil leakage of voltage stabilizer of any capacity, disconnection of LV ends, opening the top cover by using tripod, chain & pulley after removing of all fitments, replacing the components of the stabilizer such as gasket 'O' rings etc. rectify the leakes in a variety of areas such as radiator fins, flanges, valves, fastener assemblies, oil leakage through pin hole / crack joint, drain valve, radiator valve, oil leakages through gasket joint etc including repair leakage by 'M' seal Monoplast where ever necessary including welding/Brazing, testing, refixing the top cover and all fitments, LV connection and testing complete all as specified and directed .
Supply & filling of transformer oil in transformer in situ/at site for toping up the level of oil having dielectric strength 40 - 60 KV during filling after initial filtration conforming to IS-335, Transformer oil shall be supplied in sealed container and empty barrel of transformer oil will be deposited by contractor in E/M store yard complete all as specified and directed. Make: HP / BPL / IOC
Dehydration / filtration of transformer oil of existing transformer installed at site with portable plant to improve the dielectric strength 40 to 60 KV during filling after initial filtration including testing of dielectric strength after dihydration at site complete all as specified and directed.
M&L for painting of voltage stabilizer indoor / outdoor of capacity 45 to 100 KVA on plinth / pole / in workshop with one coat of synthetic enamel paint with compressor spray Gun after removing all dust, rust, paint shall confirmed to IS-2032 and writing SM & MES No with letter not less than 50mm with white paint on location complete all as specified and directed.
Cutting of worn out aluminium cable terminal lugs from the LT cable, crimping of new aluminium cable core, lugs suitable size and fixing with stabilizer, terminal stud including cutting/dressing of cable, excavation surface after providing redressing of excavated surface after providing sand cushioning and brick protection complete all as specified and directed.
S&F in replacement of Aviation Light with all necessary connection complete all as specified and directed. Make: Bajaj / Crompton / Philips
S&F in replacement 2.5 sqmm 2 core Copper Flexible Cable with suitable clamps complete all as specified and directed. Make: Havells / Finolex / Polycab / Grandlay
S&F in replacement MCCB TP, 415V, 100 Amps with breaking capacity 10 KA complete all as specified and directed. Make: L&T / Legrand / Siemens / Schneider
S&F in replacement MCCB TP, 415V, 200 Amps with breaking capacity 25 KA complete all as specified and directed. Make: L&T / Legrand / Siemens / Schneider
Supply installation, commissioning & testing (in replacement ) of LT Bus Bar Panel of size 650mmX600mmX300mm, made out by CPRI approved panel manufacturer 415 volts, TPN wall / floor mounted on suitable angle iron frame outdoor type cubical made out of 2 mm thick CRCA sheet weather, dust & vermin proof with rubber gasket with high class powder coating internally & externally fixing in position by provision of nut and bolts & addition / alteration required for fixing existing cables and connecting the all incoming/outgoing cables by suitable size of aluminium lugs stands nuts, bolts & washers including to accommodate properly following control switches complete all as specified and directed:- (a) Aluminium bus bar TPN 200 Amps rating made of high conductivity aluminium strip of suitable length with sleeves - 01 Set
KRISHNA & KAVYANSH BROTHERS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .