GE (U) Elect Supply
GE U ELECTRIC SUPPLY DELHI CANTT
MANNING AND OPERATION OF 11 KV MAIN DISTRIBUTION SUB STATION AT BI LINE ARJAN VIHARSHOPING CENTRE SUB STN REPAIR REPLACEMENT OF OLD UNSV LT PANELS MCCBS CONNECTED ITEMS IN ARJAN VIHAR NEW PRATAP CHOWK PRATAP CHOWK MANDIR MARG ARMY HQ PROVOST UNI
2021_MES_421723_2
GE ELECT/D-104/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE U ELECTRIC SUPPLY DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE U ELECTRIC SUPPLY
₹70,000
Yes
26 Apr 2021
9 Mar 2021
22 Mar 2021
10 Mar 2021
20 Mar 2021
15 Mar 2021
Amount
Manning and Operation in Receiving-cum-Distribution Stn 11 KV round the clock by deployment of electrician in three shifts as specified, including Sunday and holidays under the concerned area under GE (U) E/S Delhi Cantt as per the schedule below :- BI Line Receiving cum distribution Sub Station (11KV) : (a) 1st shift from 0800 hrs to 1600 hrs. One Electrician. (b) 2nd shift from 1600 hrs to 0000 hrs. One Electrician. (c) 3rd shift from 0000 hrs to 0800 hrs. One Electrician. Arjan Vihar/Shoping Centre /New Pratap Chowk & Mandir Marg S/S (11KV) :- (a) 1st shift from 0800 hrs to 1600 hrs. One Electrician. (b) 2nd shift from 1600 hrs to 0000 hrs. One Electrician. (c) 3rd shift from 0000 hrs to 0800 hrs. One Electrician.
Note : (i) The contracotor will ensure suitable repalcement of electrician while on leave/weekly holidays and Wages for the same deemed to be included in the quoted rate. (ii ) The contractor shall ensure that electricians/ operator always be present in each shift. In case of absence of any worker the penalty @ Rs 100.00 per hours per electricians/ operator shall be imposed on the contractor. (iii) The contractor shall be responsible for maintaining the complete area (i.e. inside boundary wall ) such as building , hard standing , foothpath etc in neat and clean position . All necessary T&P for cutting /cleaning of grass and vegitation will be arranged by contractor without any extra cost. (iv) The contractor shall provide uniform , raincoat, protective clothing such as hand gloves ,helmet, safety belt , first aid box and shoes etc to all persons on duty and the cost of the same is deemed to be included in quoted rate. (v) Person employed should be working experience of working on HT and LT Installation. (vi) The contractor shall provide log sheet and maintain the the same on daily basis and the cost of the same is deemed to be included in quoted rate.
Worker's wage per person per day (inclusive of GST as applicable)
Employees Provident Fund as per existing rules (Prescribed Rate of EPF as applicable on (minimum wages without GST ) + GST Rate as applicable on Prescribed Rate of EPF as applicable on (minimum wages without GST )
Employees state insurance as per existing rules. (Prescribed Rate of ESI as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of ESI as applicable on (minimum wages without GST )
Contribution of Bonus as per existing rules. (Prescribed Rate of BONUS as applicable on (minimum wages without GST) + GST Rate as applicable on Prescribed Rate of BONUS as applicable on (minimum wages without GST)
Over head & profit on total of srl No 1.02 to 1.05 as applicable.
LWC as per existing rules on total of srl no 1.02 to 1.06. The bidder should note that the minmum wages including all statutory provisions as mentioned in item no 1.02 to 1.06 are exclusive of GST for calculating of labour cess.
NOTE For Item 1 and sub items :- (a) The quoted rate against EPF, ESIC and Bonus shall be considered for payment on actual basis. Contribution towards EPF, ESIC and Bonus is payable only after submission of valid and authentic document in support of having paid the requisite amount of bonus to the workmen, ie proof of payment. (b)The rate quoted shall not be less than minimum wages as notified by Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc as applicable and also not less than applicable rates for contribution of employer towards EPF,ESIC, BONUS and LWC under respective heading /subitems. In case the rates quoted are less than the minimum wages as notified by the Government of India / State Government / Local body whichever is higher including all statutory provisions such as EPF,ESIC,Bonus,taxes etc on the last due date of bid submission. his tender will be treated as non bonafide and will not be considered for acceptance.In such case,the lowest bidder shall be determined from amongst the valid/bonafide bids only. (c) 'NIL' or 'Zero' quoting against OH & Profit will be treated as 'Non-bonafide'.
(d) Contractor is required to quote upto two digits after decimal place or otherwise it will be consdered by rounding off to two digits after decimal place in accordance with Rules for Rounding off of Numerical Values in accordance with IS:02 OF 1960(Revised 2016) of BIS. (e) Any variation in minimum wage, liability of EPF/ESIC/Bonus/LWC/GST shall be adjusted for reimbursement/recovery as under:- (i) Variation in minimum wage including other related statutory provisions shall be adjusted in terms of Condition 63 of GCC (IAFW-2249). (ii)Variation in percentage/rate of GST and LWC shall be adjusted as per instructions in Annexure XVI of MES Manual on Contracts which deals with ‘Reimbursement/Refund on Variation in Taxes Directly Related to Contract Value’
(b) Outgoing (i) MCCB 4 pole , 160 Amps,50 Hz,415 Volts, 25 KA with thermal & magnetic release - 01 Nos (ii) MCCB 4 pole , 125 Amps,50 Hz,415 Volts, 25 KA with thermal & magnetic release - 01 Nos (iii) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 16 KA with thermal & magnetic release - 02Nos (iv) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 16 KA with thermal & magnetic release - 02 Nos (c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Note :- (i) All out going feeder shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint. (iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer
S&F in replacement of UNSV /Burnt MCCBs of capacity 630 Amps, TP, 50 KA, 415 Volts 50 Hz, AC, with thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed.
All as per srl item No 06 here in before but rating of MCCB 400 Amp, 36 KA
All as per srl item No 06 here in before but rating of MCCB 250 Amp, 25 KA
All as per srl item No 06 here in before but rating of MCCB 200 Amp, 25KA
All as per srl item No 06 here in before but capacity MCCB 125 Amp, 16KA
All as per srl item No 06 here in before but capacity MCCB 160 Amp, 16 KA
All as per srl item No 06 here in before but capacity MCCB 100 Amp, 16 KA
S&F in replacement of UNSV /Burnt MCCBs of capacity 630 Amps TPN , FP, 50 KA, 415 Volts 50 Hz, AC, with thermal and magnetic release fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable MCCB from panels etc complete all as specified and directed.
All as per srl item No 13 here in before but rating of MCCB 400 Amp, FP, 36 KA.
All as per srl item No 13 here in before but rating of MCCB 320 Amp, FP, 36 KA.
All as per srl item No 13 here in before but rating of MCCB 250 Amp,FP, 25 KA.
All as per srl item No 13 here in before above but rating of MCCB 200 Amp,FP, 25 KA.
All as per srl item No 13 here in before but rating of MCCB 160 Amp,FP, 16 KA.
All as per srl item No 13 here in before but rating of MCCB 100 Amp,FP, 16 KA.
All as per srl item No 13 here in before but rating of MCCB 63 Amp,FP, 16 KA.
S&F in renewal on load change over switch open execution of capacity 400 Amps , 4 pole , 415 volt , 50 Hz fixed in any type of existing LT panel/Feeder piller including taking out old existing unserviceable changeover from panels etc complete all as specified and directed.
S&F on load change over switchopen execution of capacity 250 Amps , 4 pole , 415 volt , 50 Hz mounted on wall with fastener and suitable size of nut and bolts after taking down old existing unserviceable MCCB/SDFU etc complete all as specified and directed.
S&F on load change over switch with SS enclosure of capacity 200 Amps , 4 pole , 415 volt , 50 Hz mounted on wall with fastner and suitable size of nut and bolts after taking down old existing unserviceable MCCB/SDFU etc complete all as specified and directed..
Supply and fixing in renewal of 3 pole power contactor ML-6 Cat No SS90921 mounted on any type/description LT panel/feeder pillar/wall after taking down old existing unserviceable contactor etc complete all as specified and directed.
Supply and fixing in renewal of 3 pole power contactor MNX-110 Cat No CS94137 mounted on any type/description LT panel/feeder pillar/wall after taking down old existing unserviceable contactor complete all as specified and directed.
Supply and fixing in renewal of Analog Time switch Cat No J648B1, 240 Volt AC , 50 Hz , mounted on any type/description LT panel/feeder pillar/wall after taking down old existing unserviceable time switch complete all as specified and directed.
Material and labour in replacement of Voltmeter 0-500 V digital type as per existing size complete all as per specified and directed.
Material and labour in replacement of Ammeter 0-400 Amp digital type per existing size complete all as per specified and directed
Supply and fixing in replacement of indicator lamp for RYB phases complete all as specified and directed.
Supply and fixing in replacement of cable gland for LT panel/feeder pilar for 70 sqmm cable to 240 Sqmm cable complete all as specified and directed.
Supply and fixing in replacement of cable gland for LT panel for 300 sqmm cable to 400 Sqmm cable complete all as specified and directed.
Note : (i)contractor should provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge.
Rajindera Enterprises
MV Engineers And Contractors
somyaenterprises
mayur enterprises
Vijay Electricals
M/s Adhikari construction co.
Ridhi engineers and builders
S S CONSTRUCTION
Microsys Controls India
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .