Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 CrAccepted-AOC CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹4.8 Cr Quoted ₹5.1 Cr | L1 | Accepted-AOC Being lowest bidder and reasonable bid |
| 2 | L2₹5.4 Cr+₹27.9 L (5.49%)Rejected-Finance NOT SPECIFIED | ₹5.4 Cr+₹27.9 L (5.49%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹5.7 Cr+₹61.6 L (12.1%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | ₹5.7 Cr+₹61.6 L (12.1%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹5.7 Cr+₹65.9 L (13.0%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹5.7 Cr+₹65.9 L (13.0%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹5.9 Cr+₹79.3 L (15.6%)Rejected-Finance 1630 SECTOR 7C CHANDIGARH 160019 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160019 | ₹5.9 Cr+₹79.3 L (15.6%) | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | United Sales Corporation L2 | SATISH AND CO L3 | GEPS PROJECTS L6 | YAUK ENGINEERS L7 | R D Bansal L4 | Shekhar Enterprises L10 | BHARAT ELECTRICAL TRADERS L1 | FIRE ENVO SAFETY ENGINEERS L9 | M/s Khialdas Constructions L8 | SAGGI ELECTRIC COMPANY L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Note: (i) Please refer schedule 'A' notes before quoting the tender. (ii) Amount of Schedule of credit shall be deducted off line by the department. | |||||||||||||
| 2.00 | Dismantling of HT Steel / PCC Pole of 11 Mtr. height etc complete all as specified and directed. | 110 | Each | 100 ₹11,000 Lowest | 1,200 ₹1,32,000 | 900 ₹99,000 | 500 ₹55,000 | 400 ₹44,000 | 500 ₹55,000 | 500 ₹55,000 | 1,500 ₹1,65,000 | 450 ₹49,500 | 760 ₹83,600 |
| 3.00 | Dismantling of cross-arms from pole / structures of M.S. channel or angle sections etc complete all as specified and directed. | 22.7 | Qtl | 100 ₹2,270 Lowest | 500 ₹11,350 | 600 ₹13,620 | 250 ₹5,675 | 200 ₹4,540 | 800 ₹18,160 | 500 ₹11,350 | 1,500 ₹34,050 | 450 ₹10,215 | 1,520 ₹34,504 |
| 4.00 | Dismantling of HT Pin/Shackle insulator any type, any size etc complete all as specified and directed. | 414 | Each | 5 ₹2,070 | 5 ₹2,070 | 10 ₹4,140 | 50 ₹20,700 | 2 ₹828 | 30 ₹12,420 | 1 ₹414 Lowest | 50 ₹20,700 | 9 ₹3,726 | 8 ₹3,312 |
| 5.00 | Dismantling of existing ACSR or AAC Conductor etc complete all as specified and directed. | 48.7 | Qtl | 200 ₹9,740 Lowest | 4,000 ₹1,94,800 | 900 ₹43,830 | 500 ₹24,350 | 300 ₹14,610 | 700 ₹34,090 | 500 ₹24,350 | 3,000 ₹1,46,100 | 540 ₹26,298 | 2,280 ₹1,11,036 |
| 6.00 | Dismantling of Stay Assembly of any type, any size etc complete all as specified and directed. | 7 | Each | 50 ₹350 Lowest | 100 ₹700 | 450 ₹3,150 | 1,000 ₹7,000 | 200 ₹1,400 | 200 ₹1,400 | 200 ₹1,400 | 1,500 ₹10,500 | 180 ₹1,260 | 456 ₹3,192 |
| 7.00 | Dismantling of Earth wire or service feeder or distributor span of any type, any size etc complete all as specified and directed. | 4 | Qtl | 100 ₹400 Lowest | 500 ₹2,000 | 900 ₹3,600 | 500 ₹2,000 | 200 ₹800 | 300 ₹1,200 | 500 ₹2,000 | 1,000 ₹4,000 | 360 ₹1,440 | 1,520 ₹6,080 |
| 8.00 | Dismantling of HT Cable with GI Pipe of any type, any size etc complete all as specified and directed. | 300 | RM | 25 ₹7,500 | 50 ₹15,000 | 90 ₹27,000 | 20 ₹6,000 Lowest | 25 ₹7,500 | 70 ₹21,000 | 50 ₹15,000 | 100 ₹30,000 | 90 ₹27,000 | 152 ₹45,600 |
| 9.00 | Supplying and laying un- reinforced precast concrete cable cover, class HV, type 1, size 300mm x 180mm x 40mm for laying in trenches for cable protection laid adjacent to each other length wise perpendicular to the central axix of cable complete all as specified and directed. | 84,278 | Each | 28 ₹23,59,784 | 40 ₹33,71,120 | 36 ₹30,34,008 | 35 ₹29,49,730 | 27 ₹22,75,506 | 40 ₹33,71,120 | 20 ₹16,85,560 Lowest | 80 ₹67,42,240 | 45 ₹37,92,510 | 29 ₹24,44,062 |
| 10.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC sheathed, armoured HT electric power cables (heavy duty) 11000 Volts (earthed) grade with stranded aluminium conductor of size 120 sq mm 3.0 core confirming to IS 7098 (Part-I) complete all as specified and directed. | 16,870 | RM | 1,100 ₹1,85,57,000 | 1,105 ₹1,86,41,350 | 1,044 ₹1,76,12,280 | 1,150 ₹1,94,00,500 | 1,165 ₹1,96,53,550 | 1,190 ₹2,00,75,300 | 1,070 ₹1,80,50,900 | 600 ₹1,01,22,000 Lowest | 1,170 ₹1,97,37,900 | 1,186 ₹2,00,07,820 |
Tender Value
₹7.4 Cr
EMD Value
₹6.9 L
Closing Date
26 Jun 2025, 6:00 pmClosed
CHIEF ENGR, BHOPAL ZONE
HQ CHIEF ENGR BHOPAL ZONE, MES SI LINE BHOPAL 462001
REPLACEMENT OF OH ELECTRIC CABLE BY UG CABLE AND CONNECTED WORKS AT SI LINES AND DRONACHAL IN BHOPAL PHASE-II OF II PHASES UNDER GE DRONACHAL
2025_MES_711089_1
CEBZ/BPL/TOKEN/01 OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Bhopal
As per NIT document
5 documents required · 5 mandatory
₹3,000
GE Dronachal
₹6.9 L
Bhopal
29 Sept 2025
29 May 2025
28 Jun 2025
29 May 2025
26 Jun 2025
19 Jun 2025
10 Jun 2025
Amount
Note: (i) Please refer schedule 'A' notes before quoting the tender. (ii) Amount of Schedule of credit shall be deducted off line by the department.
Dismantling of HT Steel / PCC Pole of 11 Mtr. height etc complete all as specified and directed.
Dismantling of cross-arms from pole / structures of M.S. channel or angle sections etc complete all as specified and directed.
Dismantling of HT Pin/Shackle insulator any type, any size etc complete all as specified and directed.
Dismantling of existing ACSR or AAC Conductor etc complete all as specified and directed.
Dismantling of Stay Assembly of any type, any size etc complete all as specified and directed.
Dismantling of Earth wire or service feeder or distributor span of any type, any size etc complete all as specified and directed.
Dismantling of HT Cable with GI Pipe of any type, any size etc complete all as specified and directed.
Supplying and laying un- reinforced precast concrete cable cover, class HV, type 1, size 300mm x 180mm x 40mm for laying in trenches for cable protection laid adjacent to each other length wise perpendicular to the central axix of cable complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC sheathed, armoured HT electric power cables (heavy duty) 11000 Volts (earthed) grade with stranded aluminium conductor of size 120 sq mm 3.0 core confirming to IS 7098 (Part-I) complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 120 Sqmm to 185 sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 120 Sqmm to 185 sqmm complete all as specified and directed.
Supply and fixing cable jointing kit for 11 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminium conductor cable of size 120 Sqmm to 185 sqmm complete all as specified and directed.
Supply,installation,testing and commissioning of 11 KV,630A,Extensible Outdoor type (IP54), Thickness of outer cell is 3.15mm RMU (Ring Main Unit) with 1 No. Bus PT Metering 8-way comprising of 02 Nos motorised Spring charging fixed-type load break switch as incomer and out going 06 Nos, motorised charging fixed-type Vaccum Circuit Breaker as Outgoing, inside robotically welded stainless steel 304/441 (NonFerrite Non magnetic grade) tank having min thickness 2.0mm with IP67 Degree of protection. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions ,spring charging handle & complete with all accessories. The RMU shall be type tested for internal arc, IAC AFRL 21 kA for 1 sec for both tank & cable compartment. Suitable battery charger as per no of functions of RMU shall be provided in RMU. The earthing busbar shall be provided inside each cable compartment for solid earthing of cable sheilds. The outer cable door should be as per IP-54 and manufacturers designeded specification for providing fail-safe protection. The unit shall include the following with all necessary standard fitting as required at site. All module should accommodate in one tank to avoid multiple coupling at site complete all as directed and specified.Note:- The PCC foundation work as per manufacturers instruction/design shall be measured and paid separately under relevant item of sch 'A'.The RMU shall be capable of operating normally within the following temperature range: Design ambient air temperature: + 40 ° C (option +50°C with derating) Minimum air temperature: - 5°C (option -25°C) IEC 62271-1 common clauses for MV switchgear standards, IEC 62271-200 2011 MV metal-enclosed switchgear, IEC 62271-103 2011 MV Switches IEC 62271-102 2013 AC disconnectors and earthing switches, IEC 62271-100 2012 MV AC circuit breakers, IEC 62271-105 2012 MV AC switch-fuse combination,
(A) Incomer :- Load break switch SF6 insulated Motorized Breaker module - 02 Nos and each Load break switch comprising of following accessories :- Each feeder with switch consists of :- 1. Motorised 630A load breaker switch with built-in each switch with full making capacity -01Nos 2. Mechanical position indicator switch ON/OFF/EARTHED - 1No. 3. Live Cable Indication - 1No. 4. cable compartment cover interlocked with earth switch - 1No. 5. Cable termination bushings suitable for 1No. 1CX120 sqmm XLPE cable - 1No. 6. Fault Passage Indicator with associated CTs - 1No . 7. Digital Multifunction Meter with RS-485 port (A, V, KW, KVA, KWh, Pf, F,etc ) 1No. 8. NO/NC contact for :- (a) Isolator ON/OFF. (b) Earth switch ON/OFF. (c) Fault Indicator Operated. Command Output for :- (a) isolator close. (b) Isolator Open. (c) FPI reset 1 set. 9. Mechanical interlock between incomers. 10. Resin cast, Ring Core CTs of suitable capacity for protection installed away from bushing to prevent saturation of core. CT ratio to be confirmed during drawing approval - 03No. Bus PT : 03NOs. Potential transformers with HT fuse on primary side and MCB on secondary side for protection and primary voltage :22000:V3v & secondary voltage: 110:V3v with burden winding 50VA, class of winding 1- 1set.
(B) Outgoing :- VCBs, SF6 insulated Motorized Breaker module -06 Nos and each VCBs Breaker comprising of following accessories :- 50 breaking operations (E2) at Rated Short Circuit Current on Circuit Breakers (i) 11KV,630A fixed-type Vaccum Circuit breaker module for making and breaking of fault current alongwith disconnector + Earth switch of Full making capacity. (ii) Short time current 16 to 20 KA/3sec,breaking capacity (iii) Auxillary contacts -1NO + 1NC (iv) Manual/motorized spring-charging,associated closing/tripping coils. (v) Spring- charging operating handle and ON/OFF push buttons mechanically latches to the mechanism. (vi) cable box with cable cover interlock for front termination of the cable suitable upto 2 R x 3 core 120 sqmm (XLPE) for load break switch and upto 1R x 3 core 120 sqmm (XLPE) for VCB feeder. Cable door should be as per IP54 and manufacturer design and specification. (vii) Numerical based self-powered OC+EF protection Relay, Over Current (min,setting 20%), Earth-fault (min.setting :10%) (viii) Resin cast, Ring Core CTs of suitable capacity for protection (Acc.Cl.5P10),installed away from bushing to prevent saturation of core. CT ratio to be confirmed during drawing drawing approval -03Nos. (ix) Cable covers with self interlocking mechanism between doors,earth switch, disconnector & VCB. (x) capacitive voltage indication fixed type system. (xi) Mechanical Indications for breaker ON, OFF,EARTH,spring charged- Discharged.
Ditto All as per above Item No.14.00,14.01 & 14.02 but 7 Way comprising the following for Panel :- Incomer:- Load break switch SF6 insulated Motorized Breaker module - 02 Nos Out going:- VCBs, SF6 insulated Motorized Breaker module -05 Nos
Ditto All as per above Item No.14.00,14.01 & 14.02 but 6 Way comprising the following for Panel :- Incomer:- Load break switch SF6 insulated Motorized Breaker module - 03 Nos Out going:- VCBs, SF6 insulated Motorized Breaker module -03 Nos
Ditto All as per above Item No.14.00,14.01 & 14.02 but 6 Way comprising the following for Panel :- Incomer:- Load break switch SF6 insulated Motorized Breaker module - 02 Nos Out going:- VCBs, SF6 insulated Motorized Breaker module -04 Nos
Ditto All as per above Item No.14.00,14.01 & 14.02 but 5 Way comprising the following for Panel :- Incomer:- Load break switch SF6 insulated Motorized Breaker module - 02 Nos Out going:- VCBs, SF6 insulated Motorized Breaker module -03 Nos
Ditto All as per above Item No.14.00,14.01 & 14.02 but 5 Way comprising the following for Panel :- Incomer:- Load break switch SF6 insulated Motorized Breaker module - 01 Nos Out going:- VCBs, SF6 insulated Motorized Breaker module -04 Nos
Ditto All as per above Item No.14.00,14.01 & 14.02 but 3 Way comprising the following for Panel :- Incomer:- Load break switch SF6 insulated Motorized Breaker module - 02 Nos Out going:- VCBs, SF6 insulated Motorized Breaker module -01 Nos
Ditto All as per above Item No.14.00,14.01 & 14.02 but 3 Way comprising the following for Panel :- Incomer:- Load break switch SF6 insulated Motorized Breaker module - 01 Nos Out going:- VCBs, SF6 insulated Motorized Breaker module -02 Nos
Ditto All as per above Item No.14.00,14.01 & 14.02 but 4 Way comprising the following for Panel :- Incomer:- Load break switch SF6 insulated Motorized Breaker module - 02 Nos Out going:- VCBs, SF6 insulated Motorized Breaker module -02 Nos
Supply and fix Earth continuity conductor GI strip 32 x 6 mm or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing at burried in ground complete all as specified & directed.
Supply and fix Earth continuity conductor Copper strip 32 x 6 mm or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing at burried in ground complete all as specified & directed.
M&L for installing and commissioning Copper coated Chemical Earthing electrode of length 3 mtr, inner dia of 40 mm and outer pipe of dia 76 mm with minimum thickness of 250 micron, after boring 20 metre deep, 150 mm in dia in hard/soft soil with help of boring machine, filling the bore hole with black cotton soil upto 17 mtrs level i.e below the electrode bottom level, filling remaining portion by pouring suitable chemical bentonide compound duly mixed with water and filling earth enhancement material (minimum approx. 30 kg) into the augured hole in slurry form and allowed to set, covering of the composite structure (earth electrode + earth enhancement material), covering remaining portion with backfill soil/ material, welding copper strip with existing head of earth electrode including necessary PCC earth pit work and including all necessary nut, bolts, washers etc complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate 60cmx60cmx6.3 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanised mild steel earthing lead strip 32X6mm by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 3 of MES schedule Part-I connecting to earthing test point and testing on completion with including 15mm bore light grade GI protection pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soil, providing alternate layers of charcoal and common salt, construction of PCC earth chamber in 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover, reinforced with 8mm TMT bars 100mm C/C both ways with life hook made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, complete all as specified and directed. Note:- (i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) The unit rate includes the cost of GI pipe light grade for protection of earth strip and earh strip upto 7.5 M. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself
M&L for precast cable route Indicator made out of cement concrete 1:2:4, type B1, using (20mm graded stone aggregate) having 15cm square shape at top and 30cm square shape at bottom and total height of 100cm casted as per direction and grouted into PCC 1:2:4, type B-1, 50 cm below ground level as per site requirement including embossed with "HT 11KV Cable" and with two coat of synthetic enamel Paint and earth work in any type of soil complete all as specified and directed. NOTE - Earthwork in any type of soil deemed to be included in the quoted rates.
Construction of platform for RMU (Ring main unit) upto 3 way as per drawing provided by manufacturer and approved by GE and foundation depth 200mm including necessary earth work in any type of soil (clear height with additional 150mm Thick PCC 1:3:6 type C-2 foundation below ground level), made out of 23 cm brick masonary in cement mortar 1:6, (One side of platform to be hollowed for cable alley ), with a 100 mm thick re-inforcement cement concrete 1:2:4, type B-2, 8 mm dia MS bar as in floor of platform, plastering in CM 1:4, including stair for platform as per site requirement Complete all as specified and directed.
Construction of platform for RMU (Ring main unit) upto 4 to 5 way as per drawing provided by manufacturer and approved by GE and foundation depth 200mm including necessary earth work in any type of soil (clear height with additional 150mm Thick PCC 1:3:6 type C-2 foundation below ground level), made out of 23 cm brick masonary in cement mortar 1:6, (One side of platform to be hollowed for cable alley ), with a 100 mm thick re-inforcement cement concrete 1:2:4, type B-2, 8 mm dia MS bar as in floor of platform, plastering in CM 1:4, including stair for platform as per site requirement Complete all as specified and directed.
Construction of platform for RMU (Ring main unit) upto 6 to 8 way as per drawing provided by manufacturer and approved by GE and foundation depth 200mm including necessary earth work in any type of soil (clear height with additional 150mm Thick PCC 1:3:6 type C-2 foundation below ground level), made out of 23 cm brick masonary in cement mortar 1:6, (One side of platform to be hollowed for cable alley ), with a 100 mm thick re-inforcement cement concrete 1:2:4, type B-2, 8 mm dia MS bar as in floor of platform, plastering in CM 1:4, including stair for platform as per site requirement Complete all as specified and directed.
Supply & Fixing 100mm bore GI tubing Light grade with all fittings as required for passing through cables under floors, along the wall or along the pole, etc with suitable size M.S.flat iron clamps incl nut,bolt and washer complete all as specified and directed. NOTE - Excavation and Earthwork shall be measured and paid separately under appropriate item of this schedule)
M&L for Cutting of hard standing ,Roads,Path, plinth protections for laying of cable/ protection pipe complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) in foundation filling & mass concrete, complete all as specified & directed.
Boring of holes under road, pavement, hard standing by any mechanical method including GI medium grade pipe of 100mm dia. complete all as specified & directed.
M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan with 1:4 cement mortar for wall, plinth foundation pillar or base of pipe/ cable etc complete all as specified and as directed
S & F of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11.0 metres long) and paint with two coats of black bituminous paint through out internally and externally upto planting depth and two coasts of red and white alternate strips 30 cm each upto 1.2 mtr from the ground level and The remaining external position shall be painted with two coat of aluminium paint including numbering to pole complete all as specified and directed. NOTE - Excavation and Earthwork shall be measured and paid separately under appropriate item of this schedule)
Restringing, tightening of loose/broken ACSR conductor of any size and type, maintaining standard sag including binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia, PG clamp etc on HT over head lines consisting of 3 conductor complete all as specified and as directed.
Supply, fixing and stringing ACSR (aluminium conductor galvanized steel-reinforced) of any size and type in accordance with site requirement and binding on insulator by means of 22 gauge aluminium binding wire to permissible sag complete all as specified and as directed.
M & L for stay assembly of stay rod of diameter 20 mm with all accessories as shown in electrical plate No. 1. (Excavation and PCC work measured separately) complete all as specified and as directed.
M & L for cross arms, bracings, supports, clamps, back plates and stay clamp fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
S & F polymer pin insulator, Type B, Nominal System voltage 11 kV, highest system voltage 12 kV, visible discharge test voltage 9 kV, wet power frequency withstand voltage 35 kV, power frequency puncture withheld voltage 105 kV, impulse withstand voltage 75 kV, minimum total creepage distance 230 mm, minimum failing load 5 kN, of suitable size with galvanised steel insulator pin, nut, washers complete all as specified and as directed.
Supply and fixing triple pole mechanically operated air break isolator (GOD), vertical mounting, rotating type, mounted on insulator and steel frame with operating mechanism worked from ground level complete in all respect such as gun metal moving contacts and spring loaded gun metal fixed jaws, knife copper jumper strip etc, suitable for 11000 Volts grade, 50 Hz, with 9 insulator of rating upto 400 Amps including taking down existing GOD complete all as specified and as directed.
Material and labour for HT outdoor expulsion type lightening arrestor with mountings, accessories complete fixed on cross arms of two pole structure/GI flat strip and connect with same size of ACSR conductor with all fittings connected to earth stripwith nut, bolt, washer transmission class having discharge capacity of 65 kilo Amps and suitable for working pressure 11 KV complete all as specified and directed.
Supply,fixing ,stringing,testing and commissioning of ACSR insulated rabbit conductor 11000v Graded of size 6+1/3.35 mm (as phase wire) binding with insulators including fastners/gripper material and correction of all service connections/exisitng cables complete all as specified and as directed.
Earth work in excavation in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan and nexc 1.5 m in depth including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the Soft / loose soil complete all as specified and directed .
Earth work in excavation in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan and nexc 1.5 m in depth including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the hard dense soil complete all as specified and directed .
Earth work in excavation in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan and nexc 1.5 m in depth including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the Hard rock complete all as specified and directed .
Excavating in post holes (or similar holes) each n.exc 0.5cum, getting out, returning, filling in and remaining earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n.exc 50m and making good surface in soft/loose Soil complete all as specified and directed.
Returning filling in all kind of soil, including spreading, levelling,watering and well ramming in layer not exceeding 25 cm in each layer, complete all as specified & directed.
Removal of Excavated Soil to a distance not exc. 50 Mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed.
M & L For sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8cm below cable & 15cm above cable) complete all as specified and directed. Note: Compacted/punned thickness shall be measured & paid.
M & L For sand filling under floor or in foundation including watering & consolidation as in bedding layers for laying tiles complete all as specified and directed.
Dismantling of stone slabs of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
Demolition of Unreinforced Concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. complete all as specified and directed.
Dismantling of fencing wire mesh, any type complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
M & L Hardcore of broken stones gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface including removal of exiting loose soil complete all as specified and directed.
M & L for 100mm thick P.C.C 1:3:6 type C2 Using 40mm graded stone aggregate as sub base floor complete all as specified and directed.
Material & labour, for machine pressed precast concrete Interlocking paver block finished with grey cement & pigment confirming to IS 15658-2006 of 60mm thickness M-35 Grade & size, shape and pattern as approved by GE, complete all as specified & directed.
Material & labour, for machine pressed precast concrete Interlocking paver block finished with grey cement & pigment confirming to IS 15658-2006 of 80mm thickness M-40 Grade & size, shape and pattern as approved by GE, complete all as specified & directed.
Labour for except tiles, refixing for machine pressed precast concrete Interlocking paver block finished with grey cement & pigment confirming to IS 15658-2006 of 60mm thickness M-35 Grade & size, shape, pattern as approved by GE, complete all as specified & directed.
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating including form work complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) in foundation filling & mass concrete, complete all as specified & directed.
M&L for plain cement concrete (1:3:6) type C-2 , Concrete bed to 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified & directed.
M&L for plain cement concrete (1:3:6) type C-2 , Concrete bed to 450mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified & directed.
Material and labour for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in lintal upto 1.5m span, bands, string course, copings, apex stone, bed plate, kerbs, haunching and the like including weathering, slightly rounded or chamfered angle with and including necessary use and waste of form work complete all as specified & directed.
Material and labour for Pre-cast cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) block masonry with solid blocks, exc. 10cm in width and setting in mortar 1:4 as in walls of manhole, complete all as specified & directed.
M&L providing precast cement concrete type B1 (1:2:4) using 20mm graded aggregate as in landing cover, drain cover, man hole cover water troughs and in similar work and set in CM 1:4 etc complete all as specified and directed.
Material and labour for Cement Concrete 1:4:8 type D-2 (40mm graded crushed stone aggregate) in foundation, filling and mass concrete in foundation etc complete all as specified and directed.
M&L Mild steel TMT bars above but 6 to 8mm dia bar and over cut to length bend to shape as required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia. complete all as specified and directed.
Material and Labour for 150 mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches and jointed in CM (1:1) including testing complete all as specified & directed. Note : Excavation, Returning filling and removal shall be measured and paid seperately.
Material and Labour for 450 mm bore Reinforced concrete pipes, class NP2, laid and jointed complete with collars laid in trenches and jointed in CM (1:1) including testing complete all as specified & directed. Note : Excavation, Returning filling and removal shall be measured and paid seperately.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc
Material and labour for rendering 15mm thick in cement mortar 1:4 on fair surfaces of brick work or concrete surfaces finished even and smooth without using extra cement and with WPC complete all as specified and directed. (WPC Shall Be measured and paid separately)
Material and labour for rendering 10mm thick in cement mortar 1:4 on fair surfaces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Supply only Integral water Proofing compound complete all as specified and directed.
Material and labour for old size Fly Ash Brick work , straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
Supply & fixing Mild steel work of Fe-290 Gde E -165 as in angle iron fencing posts & flat iron drilled and countersunk for boulders running bars,including embedding in concrete and scruing etc,post and struts in fencing including cutting, tops to shape as directed, bent to shape, drilling holes, notching for wire etc,flat iron fillets (for securing wire mesh etc.) Including all necessary drilling,bolting or riveting etc.complete all as specified and shown on drawings. Note:- The element of Fixing of round bars for chain link fencing is included in this item .Nothing shall extra be paid on this account .
Supply & fix Bands, straps, supports or stays for hooks for hanging fans similar conforming to Fe-290 Gde E-165 complete all as required at site complete all as specified and directed.
Supply only Chain link fencing including line wires, any mesh, size and type to any type of standard, rails, straining bolts etc including provision of binding wire complete all as specified and directed.
Fixing only Chain link fencing including line wires, any mesh, size and type to any type of standard, rails, straining bolts etc including provision of binding wire complete all as specified and directed.
M&L mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm in length, dia of neck 11 to 15 mm complete all as specified and directed.
S&F mild steel round bars 10mm dia and over cut to length bent to shape required including cranking, bending, spirally for hooking ends stiffeners confirming to FE-410-W ( Gde E 250) quality-A or Fe 290 (Gde E-165) complete all as specified and directed
M&L for 2 coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description exc 10 cm in width or girth complete all as specified and directed.
M&L for 2 coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description n exc 10 cm in width or girth complete all as specified and directed.
S&F for Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire complete all as specified and directed. NOTE : Each line of barbed wire will be measured separately.
United Sales Corporation (BID ID -3331616)
SATISH AND CO (BID ID -3334897)
R D Bansal (BID ID -3337561)
SAGGI ELECTRIC COMPANY (BID ID -3330642)
GEPS PROJECTS (BID ID -3336297)
YAUK ENGINEERS (BID ID -3337474)
M/s Khialdas Constructions (BID ID -3337633)
FIRE ENVO SAFETY ENGINEERS (BID ID -3337776)
Shekhar Enterprises (BID ID -3337679)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
BOQ_796334.xls
BOQ • 0.32 MB
171781757.pdf
Tender Documents • 0.34 MB
171781762.html
Tender Documents • 0.05 MB
tender.pdf
Tender Documents • 2.95 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .