Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.1 LAccepted-AOC 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | L-1 | Accepted-AOC BEING FIRST LOWEST | |
| 2 | L-2₹24.0 L+₹2.0 L (8.99%)Rejected-Finance NO 45 5TH CROSS MALLAPPA LAYOUT BABUSAPALYA KALYAN NAGAR BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L-2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L-3₹29.2 L+₹7.2 L (32.6%)Rejected-Finance | L-3 | Rejected-Finance BEING NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹51,260
Closing Date
17 Sept 2020, 6:00 pmClosed
GE (AF) MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
SPECIAL REPAIRS TO WIRING, LT PANELS AND DISTRIBUTION BOXES OF P-2 BLDG AT ASTE AND PROVN OF AUTOMITIC METER READING (AMR) SYSTEM IN CERTAIN OMQs AT VISHWA VIHAR CAMP OF ASTE UNDER GE (AF) MARATHAHALLI BANGALORE.
2020_MES_372616_1
GE (AF) MARATHAHALLI / 8853 / E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) MARATHAHALLI
Class E and above with Category b (I)
7 documents required · 7 mandatory
₹500
Yes
GE (AF) MARATHAHALLI
₹51,260
Yes
GE (AF) MARATHAHALLI
15 Dec 2020
27 Aug 2020
19 Sept 2020
27 Aug 2020
17 Sept 2020
31 Aug 2020
27 Aug 2020 - 31 Aug 2020
31 Aug 2020
Amount
Taking down carefully Unserviceable Copper / Aluminium Point Wiring of any type batten or conduit, surface or concelaed (Light, Fan, Socket or power) complete including removing material from site and making good the disturbed surfaces of walls, roofs etc to match the existing Complete all as specified and as directed. (Note: Taking down of Fittings and Fixtures shall be measured under respective Items Separately).
Taking down carefully Unserviceable Sub main wiring of any size and type batten or conduit, surface or concelaed including removing material from site and making good the disturbed surfaces of walls, roofs etc to match the existing Complete all as specified and as directed. (Note: Taking down of Fittings and Fixtures shall be measured under respective Items Separately).
Taking down carefully unserviceable distribution boards/metal enclosures of any type and capacity including wooden board and making good the disturbed surfaces of walls, ceilings etc including two coats of white/colour washing/ distempering etc to match the existing complete all as directed by EIC.
Material and Labour for wiring complete 1.5 sqmm FRLS grade single core PVC insulated, unsheathed, 1100V grade copper multistranded conductor drawn through existing rigid metallic/non metallic pvc conceiled conduit 20 mm dia in walls, roofs floors etc including PVC insulated copper earth continuity conductor 1.5 Sqmm cable connected to common earth dolly including replacing of steel terminal boxes made out of 1.6 mm thick with modular plates suitable for mounting modular switches/sockets concealed in walls for housing the switches, sockets regulators etc all as specified and directed for One light point controlled by one switch.
All as per item No. 4 above but One fan fan point controlled by one switch.
All as per item No. 4 above but One Ex fan point controlled by one, one way switch 05/06 Amps
All as per item No. 4 above but One 5 Amps socket point on independent board.
All as per item No. 4 above but One bell point controlled by one switch.
All as per item No. 4 above but One 5 Amps socket point on same board with other switches
All as per item No. 4 above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board.
Material and Labour for New conceiled condiut point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of 20mm dia size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes to accomodate modular switches including PVC insulated copper earth continuity conductor 1.5 Sqmm cable connected to common earth dolly including steel terminal boxes made out of 1.6mm thick MS sheet concealed in walls for housing the Modular type switches, sockets regulators etcwith modular plates all as specified and directed for one switch/light/bell point controlled by one switch or One 2 / 3 pin, 5 / 6 Amps Socket outlet point on Independent board controlled by one, One way 5 / 6 Amps switch Complete all as specified and as directed.
Material and Labour for New conceiled condiut point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of 20mm dia size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes to accomodate modular switches including PVC insulated copper earth continuity conductor 1.5 Sqmm cable connected to common earth dolly including steel terminal boxes made out of 1.6mm thick MS sheet concealed in walls for housing the Modular type switches, sockets regulators etcwith modular plates all as specified and directed for One 5 amps socket point on the sameboard with other switches. Complete all as specified and as directed.
Material and Labour for New conceiled condiut point wiring with 2.5 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of 20mm dia size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes to accomodate modular switches including PVC insulated copper earth continuity conductor 2.5 Sqmm cable connected to common earth dolly including steel terminal boxes made out of 1.6mm thick MS sheet concealed in walls for housing the Modular type switches, sockets regulators etcwith modular plates all as specified and directed for one switch/light/bell point controlled by one switch or One 3 pin, 15 Amps Socket multipurpose on independent board Complete all as specified and as directed.
Material and Labour for New conceiled condiut point wiring with 4.0 sqmm nominal cross sectional area, single core, 1100 Volts FRLS grade, stranded, PVC insulated, unsheathed copper conductor cable drawn through PVC concealed conduit of 20mm dia size, complete with all PVC conduit accessories/ fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes to accomodate modular switches including PVC insulated copper earth continuity conductor 4.0 Sqmm cable connected to common earth dolly including steel terminal boxes made out of 1.6mm thick MS sheet concealed in walls for housing the Modular type switches, sockets regulators etcwith modular plates all as specified and directed for one switch/light/bell point controlled by one switch or One 3 pin, 15 Amps Industrial socket for AC 1.5/2.0 Ton capacitye on independent board Complete all as specified and as directed.
Supply and Fixing in repairs bell (Ding-Dong) 230 volt, single pole, Complete all as specified and as directed. (Make: Havell`s / Anchor / Legrand)
Supply and Fixing in repairs Ceiling rose, 3 phase / PVC / polycarbonate, isolated body Complete all as specified and as directed. (Make: Havell`s / Anchor / Legrand)
Supply & fixing modular switch 06 Amps 1 module in replacement of old u/s complete all as specified & directed
Supply & fixing bell push modular type 6 Amps 2 Module in replacement of old u/s complete all as specified & directed.
S & F modular socket 06 Amps 2/3 pin combined 2 module in replacement of old u/s complete all as specified & directed.
Supply & fixing modular switch 16 Amps 1 module in replacement of old u/s complete all as specified & directed
S & F modular socket 06/16 Amps 2/3 pin combined 2 module in replacement of old u/s complete all as specified & directed.
S & F electronic fan regulator modular type, 2 module, 120W in replacement of old u/s including complete all as specified and directed.
S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1 No. MCB 20 Amp capacity complete all as specified and as directed
Supply and fix LED Tube light fitting 1 x 22W , Surface mounted , industrial box type luminaire with CRCA body, pre- coated in white & pre- wired for LED tube, bipin holders, connector block etc.,including 20W -1 No LED T8 tubular lamp with in built driver, complete with all accessories and including connecting up with 2 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete including taking down old light fittings all as specified and as directed Make :(i) Cat part No :REGALBATTEN8UPTO 1X22WSSBSWH of Havells for fitting or equivalent Crompton/Philips (ii) Cat part No :CRYSTAL 1213 T8DSTL 20 WLED865SGLASS of Havells for fitting or equivalent Crompton/Philips
Supply and fix LED Tube light fitting 2 x 22W , Surface mounted , industrial box type luminaire with CRCA body, pre- coated in white & pre- wired for LED tube, bipin holders, connector block etc.,including 20W -2 No LED T8 tubular lamp with in built driver, complete with all accessories and including connecting up with 2 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete including taking down old light fittings all as specified and as directed Make :(i) Cat part No :REGALBATTEN8UPTO 2X22WSSBSWH of Havells for fitting or equivalent Crompton/Philips (ii) Cat part No :CRYSTAL 1213 T8DSTL 20 WLED865SGLASS of Havells for fitting or equivalent Crompton/Philips
Supply and fix LED Tube light fitting 1 x 12W , Surface mounted , industrial box type luminaire with CRCA body, pre- coated in white & pre- wired for LED tube 2feet, bipin holders, connector block etc.,including 12W -1 No LED T8 tubular lamp with in built driver, complete with all accessories and including connecting up with 2 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete including taking down old light fittings all as specified and as directed Make :(i) Cat part No :REGALBATTEN8UPTO 1x12 WSSBSWH of Havells for fitting or equivalent Crompton/Philips (ii) Cat part No :CRYSTAL 1213 T8DSTL 13 WLED865SGLASS of Havells for fitting or equivalent Crompton/Philips
Supply and Fix compact & decorative energy efficient round LED 12W surface mounted light fitting with lamp and making all connections including taking down old fittings all as specified and as directed. Make: Cat no- 12 LED 4000K,LHEAAVP61LW012 of Havells or equivalent in Philips/Crompton.
Supply and fixing Flase ceiling fitting 28 W LED Fitting, 2' x 2' recess / Surface LED flat panel with high brightness LED for glare free homogenous illumination including LED driver complete all as specified including Connection with twin core flexible wire of suitable size all as specified and as directed by Engr- In - Charge. Make : Cat No : PLUTONEO2X2PLR28W LED840S of Havellsor equivalent in crompton/ Bajaj/HPL
Supply and fixing Flase ceiling fitting 30 W LED Fitting, (size-1195x 295 x 70 mm)' recess / Surface LED flat panel with high brightness LED for glare free homogenous illumination including LED driver complete all as specified including Connection with twin core flexible wire of suitable size all as specified and as directed by Engr- In - Charge. Make : Cat No : PLUTONEO4X1PLR30W LED840S of Havellsor equivalent in crompton/ Bajaj/HPL
S & F MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. Make : Havells or equivalent in Standard/ Indoasian
S & F MCB SPN 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. Make : Havells or equivalent in Standard/ Indoasian
S & F MCB SPN 40 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. Make :Havells or equivalent in Standard/ Indoasian.
S & F MCB TP 63 Amps, 'C' series, 240 V complete incl making conections all as specified and directed. Make : Havells or equivalent in Standard/ Indoasian.
Taking down Old U/S MCB DB TPN 4 Way, S & F MCB DB TPN 4Way with 200 Amps rated busbar, Double door, 440 volts flush to wall including all cutting etc on wall and making good the disturbed surfaces to match the existing complete all as specified and directed.
All as per ser item no. 30 here-in-before but TPN 8 way, 440 Volts complete all as specified.
Taking down Old Unserviceable MCCB DB TPN, Supply and fixing Powerline Vertical DB, Double door suitable for TP/FP MCCB SKB as incomer, 12Way, 415volts, flush to wall including Removing&Reconnecting existing wires/Cables,gland,lugs,cutting on wall and making good the disturbed surfaces to match the existing complete all as specified and directed. Make : Havells or equivalent in Standard/ Indoasian
Taking down unserviceable MCCB and Supply & Fix MCCB TP 415 Volts 100 Amps rating with breaking capacity of 25 kA,fixed thermal & magnetic setting complete with making all connections as specified and directed.Make : Havells or equivalent in Standard/ Indoasian
M & L for sub main wiring complete with two runs of 6 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories in surface of wall, roofs etc with one run of PVC insulated copper conductor 6 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
Supply and Installation of AMR Enable Single Phase Meter with the following specifications: • AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, basis current 10 A- 60 A, Max continuous current 600% of basis current conforming to IS-13779 and relevant IEC standards with inbuilt Low Power Radio Frequency (LPRF) communication facility in CyanConnode or equivalent Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry. • Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, monthly billing survey for Cumulative Energy and Max Demand, Including taking down old Energy Meters and depositing at MES store yard all as specified and directed by Engr- in - charge. MAKE: Capital, L&T, CyanConnode
Supply and Installation of AMR Enable Three Phase Meter with the following specifications: • AC three Phase four Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, basis current 10 A-60A , Max continuous current 600% of basis current conforming to IS-13779 and relevant IEC standards with inbuilt Low Power Radio Frequency (LPRF) communication facility in CyanConnode or equivalent Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry. • Meter Should support the following data : 30 min instantaneous data for voltage, current, power factor, power, cumulative energy, cumulative apparent energy and frequency, monthly billing survey for Cumulative Energy and Max Demand, Including taking down old Energy Meters and depositing at MES store yard all as specified and directed by Engr- in - charge. MAKE: Capital, L&T, CyanConnode
Supply and Installation of Data Concentrator Units (DCU) with the following specifications: • IP 51 rated Data Concentrator Unit (DCU) compatible for remote Automatic Meter Reading (AMR) solution and capable of communicating with the static energy Meter in the corresponding frequency band and with the data server through GPRS and shall have minimum data transfer rate of 9600 bps, internal memory to store data of 50 modules for 6 month period and shall be based on CyanConnode or equivlent Mesh network. Make: Capital, L&T, CyanConnode
Supply and Installation of Repeater unit with inbuilt Low Power Radio Frequency (LPRF) Communication Facility and capable of communicating within CyanConnode or equivalent Mesh network with inbuilt AC power supply. Make: L&T, Capital, CyanConnode
Hosting and Configuration of the Web based Software with following modules: (i) Meter Data Management Module The meter data management module would be responsible for collecting the data from the concentrator and make the data available to the billing system. The meter data management system would capture and provide the following data: (a) 30 min instantaneous data from all the meters for seven parameters – Cumulative Energy, Cumulative Apparent Energy, Power, Current, Voltage, Power Factor and Frequency (b) Monthly and quarterly billing survey data for cumulative energy and max demand (ii) Billing Module The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data / billing data available to admin and end users. The system would support occupation / vacation and billing reports. the software would be collecting data from DCU. The software would provide excess to staff as well as the occupant for the data. Make: Innologix, Cyantech, L&T
Four year annual maintenance support for the software and GPRS provisioining after one year completion of warranty after project completion
M/S Suresh Raju
SREE VARU ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .