Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-Finance 4TH FLOOR VOLTAS HOUSE A BLOCK DR BABASAHEB AMBEDKAR ROAD CHINCHPOKLI MUMBAI MAHARASHTRA 400033 | MUMBAI | MAHARASHTRA | 400033 | ₹1.1 Cr | L1 | Accepted-Finance Being L1 |
| 2 | L2₹1.1 Cr+₹51,655 (0.46%)Rejected-Finance | ₹1.1 Cr+₹51,655 (0.46%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹1.2 Cr+₹4.6 L (4.03%)Rejected-Finance 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | ₹1.2 Cr+₹4.6 L (4.03%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹1.3 Cr+₹12.9 L (11.4%)Rejected-Finance | ₹1.3 Cr+₹12.9 L (11.4%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹1.3 Cr+₹15.0 L (13.3%)Rejected-Finance E3 172 ARERA COLONY NEAR 10 NO MARKET ARERA COLONY BHOPAL MADHYA PRADESH 462016 | BHOPAL | MADHYA PRADESH | 462016 | ₹1.3 Cr+₹15.0 L (13.3%) | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | VOLKS ENERGIE PVT LTD L3 | VOLGA AIR TECHNOLOGIES INDIA L5 | Voltas Limited L1 | UTILITY SERVICES L2 | AIR DESIGN SOLUTIONS L6 | Mvac Engineers L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Consultancy charges for heat load design of HVAC system as per enclosed ambient conditions of existing Terminal building of Ayodhya Airport by specialized agency/consultant using HAP /latest software and applicable tools etc. including visit at site to collect details of building/data , submission of heat load calculation in hard copy as well as in soft copy area wise and as total heat load of building . The heat load of building shall be designed in two parts (i) Total heat load along with effect of sky light (ii) Total heat load without effect of sky light etc. complete as required. | 1 | Job | 75,000 ₹75,000 | 1,20,000 ₹1,20,000 | 63,291 ₹63,291 | 35,428 ₹35,428 Lowest | 50,000 ₹50,000 | 37,500 ₹37,500 |
| 2.00 | VRV/VRF OUT DOOR UNITS
Supply, Installation, testing & commissioning of variable refrigerent volume / flow modulur type Heat Pump (Heating & Cooling type) outdoor unit equiped with highly efficient hermetically sealed rotary /scroll type inverter compressor(s) with 14 HP onwards having multiple compressor, special heat exchanger, y branch unit support, auto check function for connection error, Refrigerant R-410A, with Variable refrigerant temperature, auto gas charging facility for proper gas charging / as per OEM, refrigerant cooled PCB for long life of PCB/as per OEM. The EER at 100% load shall be not be less than 3.73 for 20 HP outdoor unit heat pump suitable to operate from 380-415 volt, 50 Hz,3 phase AC power supply complete with individual controller and fittings with factory wired, tested with all neccessary controls and filled with first charge of refrigerent before delivering at site , connection & termination including complete as per enclosed technical specifications. Outdoors units of the VRV system shall be compact air cooled type.The outdoor units shall be suitable to operate within an ambient temperature range of "-5 Deg C to 52 Deg C" in cooling mode; & "-15 Deg C to 15.5 Deg C" in heating mode.
The VRV/VRF units must be capable so that refrigerent piping between outdoor unit & the indoor units shall be extendable up to 165 Meter with maximum level difference between outdoor unit & indoor units of 90 m and level difference between two indoor units shall be maximum up to 30 Meter .
The compressor should be OEM manufactured/ as per OEM of unit. Including supply and installation of painted suitable size and strength MS frame for outdoor unit etc complete as required.
20 HP Outdoor Unit Heat Pump ( As per OEM higher capacity only up to 10% of mentioned capacity is acceptable without any extra cost ) | 8 | Set | 6,00,000 ₹48,00,000 | 4,95,420 ₹39,63,360 | 3,47,338 ₹27,78,704 Lowest | 3,67,689 ₹29,41,512 | 4,63,395 ₹37,07,160 | 5,18,800 ₹41,50,400 |
| 3.00 | VRV/VRF OUT DOOR UNITS
Supply, Installation, testing & commissioning of of variable refrigerent volume / flow modulur type Heat Pump (Heating & Cooling type) outdoor unit equiped with highly efficient hermetically sealed rotary/scroll type inverter compressor(s) , special heat exchanger, y branch unit support, auto check function for connection error, Refrigerant R-410A, with Variable refrigerant temperature, auto gas charging facility for proper gas charging/ as per OEM, refrigerant cooled PCB for long life of PCB/as per OEM.The EER at 100% load shall be not be less than 4.30 for 10 HP out door unit heat pump suitable to operate from 380-415 volt, 50 Hz,3 phase AC power supply complete with individual controller and fittings with factory wired, tested with all neccessary controls and filled with first charge of refrigerent before delivering at site , connection & termination, including complete as per enclosed technical specifications. Outdoors units of the VRV system shall be compact air cooled type.The outdoor units shall be suitable to operate within an ambient temperature range of "-5 Deg C to 52 Deg C" in cooling mode; & "-15 Deg C to 15.5 Deg C" in heating mode.
The VRV/VRF units must be capable so that refrigerent piping between outdoor unit & the indoor units shall be extendable up to 165 Meter with maximum level difference between outdoor unit & indoor units of 90 m and level difference between two indoor units shall be maximum up to 30 Meter .
The compressor should be OEM manufactured/as per OEM of unit. Including supply and installation of painted suitable size and strength MS frame for outdoor unit etc complete as required.
10 HP Outdoor Unit Heat Pump (As per OEM higher capacity only up to 10% of mentioned capacity is acceptable without any extra cost ) | 1 | Set | 4,00,000 ₹4,00,000 | 3,07,985 ₹3,07,985 | 2,20,946 ₹2,20,946 | 2,06,443 ₹2,06,443 Lowest | 2,53,440 ₹2,53,440 | 2,82,300 ₹2,82,300 |
| 4.00 | VRV/VRF Floor Standing Type Indoor Unit
Supply, Installation, testing & commissioning of VRV/VRF Floor Standing ductable type indoor Unit ( Heating and cooling type) of following capacity including fan with minimum airflow 6072 CFM with external static presure more than or equals to 150 Pa, microprocessor thermostat for cooling and heating , safety devices , standard accessories etc. complete as required suitable to operate from 380 V to 415 V , 50 HZ, 3 phase power supply with corded remote control, fittings etc., noise level less than or equaL to 72 DB, unit shall have control valve to control refrigerent flow rate respond to load variation of the room , have cleanable type filter fixed to an integrally moduled frame etc including supply and installation of painted suitable size and strength MS frame for indoor unit ( If required) etc complete as required as per enclosed technical specifications .
15.9 TR Ducted unit (As per OEM higher capacity only up to 10% of mentioned capacity is acceptable without any extra cost )
Note:- The indoor unit shall be installed in a big hall surrounded by toughned glass from all side . Only refrigerent pipe , electrical and communication cables shall be connected from outdoor unit . The indoor unit shall be suitable to vertically connect to accoustic insulated powder quoated rectangular / square GI duct. The Zet nozzles shall be installed in duct to throw air in diffrent direction . A picture is attached for refrence . | 8 | Set | 2,00,000 ₹16,00,000 | 1,72,177 ₹13,77,416 | 1,31,693 ₹10,53,544 Lowest | 1,49,360 ₹11,94,880 | 1,43,918 ₹11,51,344 | 1,50,900 ₹12,07,200 |
| 5.00 | VRV/VRF Ceiling mounted Indoor Unit
Supply, Installation, testing & commissioning of VRV/VRF ceiling mounted type indoor Unit ( Cooling and heating type) of following capacity including fan section with airflow range from low to high 812 to 1600 CFM ,pre filters, DX coil section, safety devices , sensors for different features ,standard accessories etc. complete as required suitable to operate from 220 V to 240 V , 50 HZ, single phase power supply with corded remote control, fittings etc. , maximum noise level should not be more than 55 DBA . The unit shall have external asthetic panel for supply and return air etc. complete as required. It includes all the MS angle/ channel/GI threaded rod etc. of suitable size and strength , fastner , nut bolts, washers etc. drilling , cutting including all civil works and making same good complete to install the unit from the ceiling.
4.0 TR Four Way Cassette unit | 2 | Set | 50,000 ₹1,00,000 | 49,872 ₹99,744 | 43,032 ₹86,064 | 37,116 ₹74,232 Lowest | 44,985 ₹89,970 | 37,700 ₹75,400 |
| 6.00 | Supply, Installation, testing and commissioning of necessary fittings, Refnet-joints and headers etc. along with all the accessories complete as required . | 6 | Set | 2,500 ₹15,000 | 6,060 ₹36,360 | 3,553 ₹21,318 | 3,344 ₹20,064 | 1,915 ₹11,490 Lowest | 3,000 ₹18,000 |
| 7.00 | Supply and charging /filling of Refrigerant R-410A as per length of copper pipe as per site requirement. | 140 | KGs | 800 ₹1,12,000 Lowest | 1,169 ₹1,63,660 | 996 ₹1,39,440 | 1,028 ₹1,43,920 | 900 ₹1,26,000 | 1,010 ₹1,41,400 |
| 8.00 | Refrigerant Piping
Supply , Installation, testing and commisioning of interconnecting following sizes of one end expanded refrigerant copper pipe work of following outer diameter ( Nominal size/as recommended by OEM, if higher size than mentioned size ( 28.6/15.9 for 20 HP and 22.2/9.5 for 10 HP) is recommended by OEM , same is acceptable ,however, payment shall be made as per mentioned size), insulated with 19/13 mm thick closed cell electrometric EPDM/nitrile rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of alluminum cladding of minimum 1.5 mm. thick of suitable size for all exposed pipes inside and outside the room as per specification. All piping inside and outside of the room shall be propelrly fixed/supported with suitable size of clamp/ M.S. hanger complete as required at site.( Whereever pipes to be laid in cable tray same shall be paid as extra )
28.6 mm dia and 1.00 mm thick with 19 mm thick EPDM/nitrile rubber insulation | 240 | Mtrs | 1,500 ₹3,60,000 Lowest | 2,220 ₹5,32,800 | 2,034 ₹4,88,160 | 2,248 ₹5,39,520 | 1,538 ₹3,69,120 | 2,230 ₹5,35,200 |
| 9.00 | Refrigerant Piping
Supply , Installation, testing and commisioning of interconnecting following sizes of one end expanded refrigerant copper pipe work of following outer diameter ( Nominal size/as recommended by OEM, if higher size than mentioned size ( 28.6/15.9 for 20 HP and 22.2/9.5 for 10 HP) is recommended by OEM , same is acceptable ,however, payment shall be made as per mentioned size), insulated with 19/13 mm thick closed cell electrometric EPDM/nitrile rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of alluminum cladding of minimum 1.5 mm. thick of suitable size for all exposed pipes inside and outside the room as per specification. All piping inside and outside of the room shall be propelrly fixed/supported with suitable size of clamp/ M.S. hanger complete as required at site.( Whereever pipes to be laid in cable tray same shall be paid as extra )
22.2 mm dia and 0.8 mm thick with 19mm thick EPDM/nitrile rubber insulation | 40 | Mtrs | 1,200 ₹48,000 Lowest | 1,445 ₹57,800 | 1,431 ₹57,240 | 1,786 ₹71,440 | 1,223 ₹48,920 | 1,480 ₹59,200 |
| 10.00 | Refrigerant Piping
Supply , Installation, testing and commisioning of interconnecting following sizes of one end expanded refrigerant copper pipe work of following outer diameter ( Nominal size/as recommended by OEM, if higher size than mentioned size ( 28.6/15.9 for 20 HP and 22.2/9.5 for 10 HP) is recommended by OEM , same is acceptable ,however, payment shall be made as per mentioned size), insulated with 19/13 mm thick closed cell electrometric EPDM/nitrile rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of alluminum cladding of minimum 1.5 mm. thick of suitable size for all exposed pipes inside and outside the room as per specification. All piping inside and outside of the room shall be propelrly fixed/supported with suitable size of clamp/ M.S. hanger complete as required at site.( Whereever pipes to be laid in cable tray same shall be paid as extra )
19.1 mm dia 0.8 mm thick with 13mm thick EPDM/nitrile rubber insulation | 20 | Mtrs | 900 ₹18,000 Lowest | 1,132 ₹22,640 | 1,260 ₹25,200 | 1,349 ₹26,980 | 1,055 ₹21,100 | 1,260 ₹25,200 |
Tender Value
₹1.4 Cr
EMD Value
₹4.1 L
Closing Date
1 Apr 2026, 11:00 amClosed
AGM(E-E), AAI
O/o AGM(E-E), AAI, MVI Airport, Ayodhya, UP-224001
SITC of additional VRV Air- Conditioning sytem in Terminal Building at MVI Airport, Ayodhya Dham
2026_AAI_270103_1
AAI/AYO/ENGG-E/VRV-AC/2025-26
Open Tender
Electrical Works
Works
90 days
MVI AIRPORT AYODHYA
As per NIT
3 documents required · 3 mandatory
₹1,180
₹4.1 L
22 Apr 2026
10 Mar 2026
2 Apr 2026
10 Mar 2026
1 Apr 2026
10 Mar 2026
10 Mar 2026 - 17 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Consultancy charges for heat load design of HVAC system as per enclosed ambient conditions of existing Terminal building of Ayodhya Airport by specialized agency/consultant using HAP /latest software and applicable tools etc. including visit at site to collect details of building/data , submission of heat load calculation in hard copy as well as in soft copy area wise and as total heat load of building . The heat load of building shall be designed in two parts (i) Total heat load along with effect of sky light (ii) Total heat load without effect of sky light etc. complete as required. | - | Job | 1.25 | - |
| 2 | VRV/VRF OUT DOOR UNITS
Supply, Installation, testing & commissioning of variable refrigerent volume / flow modulur type Heat Pump (Heating & Cooling type) outdoor unit equiped with highly efficient hermetically sealed rotary /scroll type inverter compressor(s) with 14 HP onwards having multiple compressor, special heat exchanger, y branch unit support, auto check function for connection error, Refrigerant R-410A, with Variable refrigerant temperature, auto gas charging facility for proper gas charging / as per OEM, refrigerant cooled PCB for long life of PCB/as per OEM. The EER at 100% load shall be not be less than 3.73 for 20 HP outdoor unit heat pump suitable to operate from 380-415 volt, 50 Hz,3 phase AC power supply complete with individual controller and fittings with factory wired, tested with all neccessary controls and filled with first charge of refrigerent before delivering at site , connection & termination including complete as per enclosed technical specifications. Outdoors units of the VRV system shall be compact air cooled type.The outdoor units shall be suitable to operate within an ambient temperature range of "-5 Deg C to 52 Deg C" in cooling mode; & "-15 Deg C to 15.5 Deg C" in heating mode.
The VRV/VRF units must be capable so that refrigerent piping between outdoor unit & the indoor units shall be extendable up to 165 Meter with maximum level difference between outdoor unit & indoor units of 90 m and level difference between two indoor units shall be maximum up to 30 Meter .
The compressor should be OEM manufactured/ as per OEM of unit. Including supply and installation of painted suitable size and strength MS frame for outdoor unit etc complete as required.
20 HP Outdoor Unit Heat Pump ( As per OEM higher capacity only up to 10% of mentioned capacity is acceptable without any extra cost ) | - | Set | - | - |
| 3 | VRV/VRF OUT DOOR UNITS
Supply, Installation, testing & commissioning of of variable refrigerent volume / flow modulur type Heat Pump (Heating & Cooling type) outdoor unit equiped with highly efficient hermetically sealed rotary/scroll type inverter compressor(s) , special heat exchanger, y branch unit support, auto check function for connection error, Refrigerant R-410A, with Variable refrigerant temperature, auto gas charging facility for proper gas charging/ as per OEM, refrigerant cooled PCB for long life of PCB/as per OEM.The EER at 100% load shall be not be less than 4.30 for 10 HP out door unit heat pump suitable to operate from 380-415 volt, 50 Hz,3 phase AC power supply complete with individual controller and fittings with factory wired, tested with all neccessary controls and filled with first charge of refrigerent before delivering at site , connection & termination, including complete as per enclosed technical specifications. Outdoors units of the VRV system shall be compact air cooled type.The outdoor units shall be suitable to operate within an ambient temperature range of "-5 Deg C to 52 Deg C" in cooling mode; & "-15 Deg C to 15.5 Deg C" in heating mode.
The VRV/VRF units must be capable so that refrigerent piping between outdoor unit & the indoor units shall be extendable up to 165 Meter with maximum level difference between outdoor unit & indoor units of 90 m and level difference between two indoor units shall be maximum up to 30 Meter .
The compressor should be OEM manufactured/as per OEM of unit. Including supply and installation of painted suitable size and strength MS frame for outdoor unit etc complete as required.
10 HP Outdoor Unit Heat Pump (As per OEM higher capacity only up to 10% of mentioned capacity is acceptable without any extra cost ) | - | Set | 100 | - |
| 4 | VRV/VRF Floor Standing Type Indoor Unit
Supply, Installation, testing & commissioning of VRV/VRF Floor Standing ductable type indoor Unit ( Heating and cooling type) of following capacity including fan with minimum airflow 6072 CFM with external static presure more than or equals to 150 Pa, microprocessor thermostat for cooling and heating , safety devices , standard accessories etc. complete as required suitable to operate from 380 V to 415 V , 50 HZ, 3 phase power supply with corded remote control, fittings etc., noise level less than or equaL to 72 DB, unit shall have control valve to control refrigerent flow rate respond to load variation of the room , have cleanable type filter fixed to an integrally moduled frame etc including supply and installation of painted suitable size and strength MS frame for indoor unit ( If required) etc complete as required as per enclosed technical specifications .
15.9 TR Ducted unit (As per OEM higher capacity only up to 10% of mentioned capacity is acceptable without any extra cost )
Note:- The indoor unit shall be installed in a big hall surrounded by toughned glass from all side . Only refrigerent pipe , electrical and communication cables shall be connected from outdoor unit . The indoor unit shall be suitable to vertically connect to accoustic insulated powder quoated rectangular / square GI duct. The Zet nozzles shall be installed in duct to throw air in diffrent direction . A picture is attached for refrence . | - | Set | 53 | - |
| 5 | VRV/VRF Ceiling mounted Indoor Unit
Supply, Installation, testing & commissioning of VRV/VRF ceiling mounted type indoor Unit ( Cooling and heating type) of following capacity including fan section with airflow range from low to high 812 to 1600 CFM ,pre filters, DX coil section, safety devices , sensors for different features ,standard accessories etc. complete as required suitable to operate from 220 V to 240 V , 50 HZ, single phase power supply with corded remote control, fittings etc. , maximum noise level should not be more than 55 DBA . The unit shall have external asthetic panel for supply and return air etc. complete as required. It includes all the MS angle/ channel/GI threaded rod etc. of suitable size and strength , fastner , nut bolts, washers etc. drilling , cutting including all civil works and making same good complete to install the unit from the ceiling.
4.0 TR Four Way Cassette unit | - | Set | 10 | - |
| 6 | Supply, Installation, testing and commissioning of necessary fittings, Refnet-joints and headers etc. along with all the accessories complete as required . | - | Set | 11 | - |
| 7 | Supply and charging /filling of Refrigerant R-410A as per length of copper pipe as per site requirement. | - | KGs | 10 | - |
| 8 | Refrigerant Piping
Supply , Installation, testing and commisioning of interconnecting following sizes of one end expanded refrigerant copper pipe work of following outer diameter ( Nominal size/as recommended by OEM, if higher size than mentioned size ( 28.6/15.9 for 20 HP and 22.2/9.5 for 10 HP) is recommended by OEM , same is acceptable ,however, payment shall be made as per mentioned size), insulated with 19/13 mm thick closed cell electrometric EPDM/nitrile rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of alluminum cladding of minimum 1.5 mm. thick of suitable size for all exposed pipes inside and outside the room as per specification. All piping inside and outside of the room shall be propelrly fixed/supported with suitable size of clamp/ M.S. hanger complete as required at site.( Whereever pipes to be laid in cable tray same shall be paid as extra )
28.6 mm dia and 1.00 mm thick with 19 mm thick EPDM/nitrile rubber insulation | - | Mtrs | 22 | - |
| 9 | Refrigerant Piping
Supply , Installation, testing and commisioning of interconnecting following sizes of one end expanded refrigerant copper pipe work of following outer diameter ( Nominal size/as recommended by OEM, if higher size than mentioned size ( 28.6/15.9 for 20 HP and 22.2/9.5 for 10 HP) is recommended by OEM , same is acceptable ,however, payment shall be made as per mentioned size), insulated with 19/13 mm thick closed cell electrometric EPDM/nitrile rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of alluminum cladding of minimum 1.5 mm. thick of suitable size for all exposed pipes inside and outside the room as per specification. All piping inside and outside of the room shall be propelrly fixed/supported with suitable size of clamp/ M.S. hanger complete as required at site.( Whereever pipes to be laid in cable tray same shall be paid as extra )
22.2 mm dia and 0.8 mm thick with 19mm thick EPDM/nitrile rubber insulation | - | Mtrs | - | - |
| 10 | Refrigerant Piping
Supply , Installation, testing and commisioning of interconnecting following sizes of one end expanded refrigerant copper pipe work of following outer diameter ( Nominal size/as recommended by OEM, if higher size than mentioned size ( 28.6/15.9 for 20 HP and 22.2/9.5 for 10 HP) is recommended by OEM , same is acceptable ,however, payment shall be made as per mentioned size), insulated with 19/13 mm thick closed cell electrometric EPDM/nitrile rubber tubular insulation between each set of indoor & outdoor units with outer mechanical protection of alluminum cladding of minimum 1.5 mm. thick of suitable size for all exposed pipes inside and outside the room as per specification. All piping inside and outside of the room shall be propelrly fixed/supported with suitable size of clamp/ M.S. hanger complete as required at site.( Whereever pipes to be laid in cable tray same shall be paid as extra )
19.1 mm dia 0.8 mm thick with 13mm thick EPDM/nitrile rubber insulation | - | Mtrs | 1 | - |
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.44 MB
TenderdocVRV.pdf
Tender Documents • 8.67 MB
BOQ_314852.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .