Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.1 LAccepted-AOC 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | 1 | Accepted-AOC Lowest tenderer | |
| 2 | 2₹22.8 L+₹61,392.05 (2.76%)Rejected-AOC 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | 2 | Rejected-AOC 2nd | |
| 3 | 3₹27.2 L+₹5.0 L (22.4%)Rejected-AOC | 3 | Rejected-AOC 3rd |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
7 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF TUGHLAKABAD
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
Provn of Certain New Works in Vayusenabad and Technical Area at AF Stn Tughlakabad under GE (AF) Tughlakabad
2021_MES_411291_4
GE/TKD/TOKEN-66/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE AF TUGHLAKABAD
MES contractor enlisted as Class E or above category ai,aii bi having deposited Standing Security of Rs. 50000 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
8 documents required · 8 mandatory
₹500
GE AF TUGHLAKABAD
₹50,000
Yes
27 Aug 2021
24 Jun 2021
9 Jul 2021
24 Jun 2021
7 Jul 2021
24 Jun 2021
60 days
Amount
Supply, Installing, Testing and Commissioning factory made and tested LT Outdoor type, platform mounted, suitable for 415 volts 3 phase and neutral, 4 wire, 50Hz AC Supply system having bus bar chamber with insulated electrolytic aluminium bus bars TPN of Capacity 600 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and vermin proof and made out of 3.15mm thick CRCA mild steel sheet and mild steel & angle iron frame work made out of 50mm x 50mm x 6mm), front opeining type with aprons for cable entry with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 Sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally polyester powder coaing of Siemens grey RAL - 7035 shade. The scope of work also comprising of the following (Location-Pechora Phase II) :- Make of Panel : Universal / Universal Switch Gear Control / L&T
Item No 1.00 (Contd…) INCOMING SUPPLY:- (i) ACB 630 Amps 50KA, 4 Pole with Thermal Fixed Type 415 Volts, 50 Hz - 01 No, Make of ACB : L&T / Siemens / Legrand /Havells (ii) On Load Change Over Switch 630 Amps 4 Pole without enclosure = 1 Set. Make of C/o : L&T / C&S / HAVELLS OUTGOING SUPPLY:- (i) MCCB 250 Amps 25 KA, 4 Pole with Fixed Thermal & Magnetic release 415 Volts, 50 Hz = 02 Nos (ii) MCCB 200 Amps 25 KA, 4 Pole with Fixed Thermal & Magnetic release 415, 50 Hz = 01 Nos (iii) MCCB 160 Amps 25 KA, 4 Pole with Fixed Thermal & magnetic release 415 volts, 50 Hz = 01 No (iv) MCCB 100 Amps 25 KA, 4 Pole with Fixed Thermal & magnetic release 415 Volts, 50Hz = 01 No, Make of MCCB : L&T/Siemens/Legrand / Havells
M&L for earthing complete with electrode shall be 2 Nos copper plate of size 600x600x6mm inter connected with 32x6mm copper strip of length 1.5 mtrs and in centre shall be 50 x 6mm copper strip of 3 mtr with suitable brass nut bolts and brazing for lower resistance. Alternate layers of Soil & Curec + or equivalent (03 Kgs Bag x 2), Make as per IEEE 80 2000. Clause 14.5D, maintenance free earthing system to give earthing resistance value of < 1Ω . The soil shall be mixed with backfill CURENITE (25kgs x 2 bags). Copper electrode's should be solid rod and surrounded with highly conductive and non corrosive nature (pH value certified) and covered with Poly plastic earth pit cover. Further electrodes of GI pipe at least 30mm dia shall be interconnected in paralled fashion in case low ohmage is not achievable, polyplastic pit cover enclosure shall be provided in and including boundary for poly plastic pit cover of size 1.25x1.25x0.3 mtrs of brick work duly plaster and painted as per colour coding. All certificates should be NABL LAB and CPRI certified, complete all as specified and directed by Engineer-in-Charge. Note: The contractor will render a guarantee of 24 years for satisfactory working/effectivness of earthing from the certified date of completion from manufacturer firm/executing agency. The guarantee amount towards effectiveness of earthing equal to 5% of cost of item in BOQ in the form of FDR in favour of GE (AF) Tughlakabad shall be furnished by the contractor.
Supply and fixing 32 x 6 mm Copper strip in short pieces on surface or in recess for all interconnecting, in and including taking out worn out and damaged strip complete all as specified and directed by Engineer-in-Charge.
M&L for 50mm dia heavy duty HDPE pipe PN 10 along with fittings bends, caps etc fixed to walls, underground, ceilings or in floors for protection of copper/aluminium strip of size 36 x 6mm for down conductor complete all as specified and directed by Engr-in-charge. Note: (i) HDPE pipe to be fixed/concealed after cutting on vertical wall of hanger upto 20 metre height. (ii) Necessary GI/Steel clamp required for fixing of PPR pipe on wall with the help of rawl plug and screw are deemed to be included in the quoted rate. (iii) GI/Steel clamp of suitable size to be fixed in every 1 metre gap. (iv) Necessary tool and plant for safety precautions required for fixing of pipe to be provided b the contractor and no extra cost will be paid for this work.
S&F of test point terminal block made of gun metal or phosphorus bronze of size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw fixed inside cubical shape enclosure made out of CRCA sheet 2 mm thick with front detachable cover, anodized screws, cap washers 4 Nos to be mounted on wall with wooden plugs and screws 4 Nos duly painted inside and outside by two coats of aluminium paint over a coat of primer over all dimension of enclosure 200x150x100 mm (depth) complete all as specified and directed by Engr-in-charge.
M&L for cutting the hardstanding or road by manual method upto 1000 mm deep and suitable width as per SSR for pipeline and making good the same after laying the cable with PCC 1:4:8 type-D2 by using 40mm gradded aggregate over filled, rammed earth from the top of the ground minimum 150 mm thick to match the surroundings and making good the disturbed surfaces complete all as specified and directed by Engr-in-charge.
M&L for GI brazing (welding) at site to connect loop GI earthing strip of any size after tighten by nut, bolt, washer, check nuts, complete all as specified and as directed by Engr-in-charge. Note: GI brazing shall be done upto 20 mtr height. Necessary tool/plant and ladder required for working upto 20 mtr height shall be deemed to be included in the rate quoted for above item.
M&L for Taking out the heavy duty MS duct cover of size 1200 mmx700mx8mm thick (approximate weight upto 55 Kg) and reset the same in existing position on duct after lying of cable complete all as specified and directed by Engr-in-charge
Supply, lay or fixing or passing through ducts of XLPE (FRLS) cable of aluminium conductor with heavy duty stranded, 1100 Volts of XLPE insulated PVC sheathing (heavy duty) armoured cable for working pressure up to and including 1100 volts to IS -7098 all as mentioned in SSR (Part-I) complete all as specified and as directed by the Engineer-In-Charge of size 25 Sqmm, 4 Core
Supply, Installing, testing and commissioning factory made and tested LT indoor type, platform mounted, suitable for 415 volts 3 phase and neutral, 4 wire, 50Hz AC Supply system having bus bar chamber with insulated Aluminium Bus Bars of suitable rating installed on DMC insulators with Bus Bar Chamber. The panell shall be dust and vermin proof protection class (IP-54) and Made of 2.00mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 40mm x 40mm x 6mm thick), front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5Sqmm complete. All Steel made works including frame shall be with anti-corrosive coating with seven tank process and finally epoxy polyster powder coating of Siemens grey shade 7035. The scope of work also comprising of the follwing:- Make of Panel - UNILAC / Universal switch Gear Control / SMS Panel. BUS BAR CHAMBER:- (a) 100 Amp TPN, Aluminium conductor with colour coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC Material, interconnection of all incoming & outgoings.
S&F MCCB 125 Amps 4 Pole breaking capacity 25 KA, 415 V, ICS=75 % of ICU Adjustable thermal and fixed magnetic setting type with fastening elements including taking down old unserviceable MCCB complete all as specified and directed by Engr-in-charge. Make: Cat No IHLASDCF0125# OF Havells/Cat No 422056 of Legrand/ISLASF0125 OF Standard
Excavation in trenches not exceeding 1.5 m wide & not exceeding 1.5 m deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m depth & getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cms in soft/ loose soil complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exceeding 50Mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for sand filling in trenches with approved quality dry coarse sand around cable in cushioning for protection of underground cable complete all as specified and as directed. Note: Punned thickness shall be measured and paid.
Supply and laying in trenches well burnt best quality locally available of size 23cm x 11.5cm x 7.5cm ( + 8% tolerance), sub class ‘B’ bricks for protection complete all as specified and as directed
Supply and laying of galvanised water tubing medium grade in trenches / wall / floor with all fittings connection as required at site of size 50mm bore (inner dia) complete all as specified and directed : Make : TATA / JINDAL
All as per srl item No 17.00 but GI pipe 65 mm bore (inner dia) medium grade.
S&F cast iron NRV flanged end of size 65 mm dia with all fitting and accessories complete all as specified and directed by Engr-in-charge.
S&F of gun metal gate valve with iron handle screwed both ends for iron pipe and fixed of size 50 mm bore complete all as specified and directed by Engr-in-charge.
S&F Monoblock pump set suitable for 415V, 3 Phase system having capacity 5HP, Suction Pipe 65mm, Delivery 50mm, 3000 RPM complete all as specified and directed. Make - HAVELLS / KIRLOSKAR MODEL No KDS 538 + Crompton
M&L of cast iron body foot valve, flanged ends, 65 mm bore swing type operations with rubber seat as per IS : 4038 complete all as specified and directed.
Supply & Fixing Cast Iron Strainer Y Type conforming to IS, of Size 65mm dia complete all as specified and directed. Make - ZOLOTO / KIRLOSKAR
M&L for pump set foundation and pipe filling support with PCC 1:2:4 type B1 by using 20 mm graded aggregate of any shape or size as directed including grouting of foundation bolts complete all as specified and as directed by Engr-in-charge. Note : The cost of foundation bolts deemed to be included in this items quoted rate)
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of approved colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including bending of sheet etc complete all as specified and directed by Engr-in-Charge.
M&L for MS angle iron of Size 60 x 60mm x 6 mm, MS Channels of size MC 100 and ensuring the alignment of pump and motor complete with bracing, supports, clamps and back plates fabricated form structural steel sections including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size and bolts and nuts of required size including foundation bolts and applying 2 coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engr-in-charge.
Supply, laying in trenches, duct and testing XLPE insulated (earthed) cable in screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor,1100 Volts Grade, cross sectional area 10 Sqmm 4 core conforming to IS- 7098 (Part-II) 1985 complete all as specified and directed by the Engr-in-charge.
M&L for Earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to but using GI strip 25x4 mm size and galvanised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 3 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work, PCC 1:3:6 type, C-1 by using 20mm gradded aggregate, pit with precast RCC Cover slab 40 mm thick in PCC1:2:4 type B-0 by using 12.5mm graded aggregate reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe complete all as specified in SSR and connected to earthing list point complete all as specified and as directedby Engr-in-charge.
M&L for Excavation by Trench less Boaring Technology method for making 2 mtr deep holes under road, pavement, hard standing using Ultra sound technique and engaging necessary Machine including HDPE pipe duly ISI marked of dia 65 mm suitable for 0.4 MPA working pressure complete all as specified and directed by Engr-in-charge. Note - HDPE pipe and making good the disturbed surface is deemed to be included in rate quoted by the Contractor.
M&L for brick work with sub class `B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
M&L for providing plain cement concrete 1:4:8 type D-2 by using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
M&L for half brick thick wall work with subclass 'B' Bricks straight or curved on plan to any radius built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for filling earth under floor spreading and levelling in layers not exceeding 25cm thick with well ramming including watering and consolidation all as specified and directed.
M&L for hardcore of gauge not exceeding 63mm deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface and dense soil and getting out complete all as specified and as directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in lintels blocks upto 1.5m clear span, cills, steps seismic and other similar bands plinth course lacing course, parapets and railing upto 60cm in height coping kneelers apex stones, bed plates kerbs not provided for water troughs and the like including weathering slightly rounded or chamfered angles and throating etc including necessary form work complete all as specified and directed by Engr-in-charge.
M&L for Damp proof courses to horizontal or vertical surfaces including necessary formwork in cement concrete 1:2:4, type B-0, 40mm thick including incorporating integral liquid water proofing compound in the manner specified by the manufacturers and in the proportions as indicated. Note: Water proofing compound shall be measure and paid for separately
M&L for Providing reinforced cement concrete (design mix) of grade M-25 (20mm graded aggregate) as in chhaja complete as directed.
M&L for Providing reinforced cement concrete (design mix) of grade M-25 (20mm graded aggregate) as in slab supported on wall complete as directed.
M&L for Providing reinforced cement concrete (design mix) of grade M-25 (20mm graded aggregate) as in beams, cantilevers, bressummers, linterls over 1.5m span.
M&L for Form work to chullah hoods, chajjas and similar items including edges for rough finished surface
M&L for Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, n.exc 200mm thick (Horizontal or slopping) for rough finished surfaces.
M&L for Form work to edges of concrete flats and roofs not exceeding 20 cm wide , horizontal or sloping and similar work exceeding 10 cm but not exceeding 20 cm wide for rough finished surfaces.
Mild steel TMT bars 10 mm dia and over, quality conforming to Grade 500D/550D cut to length , bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia.
Mild steel TMT bars 6 mm to 8 mm dia, quality conforming to Grade 500D/550D cut to length , bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia.
Mild steel TMT bars 5 mm dia and over upto and including 10mm dia as in stirrups, spacers and binders quality conforming to Grade 500D/550D cut to length , bent to shape required including cranking , bending and binding with mild steel wire ( annealed ) not less than 0.9mm dia.
M&L for Rendering 5mm thick cement plaster on cement concrete surfaces (ceiling) in cement mortar 1:3, finished even and smooth without using extra cement.
M&L for Rendering 15 mm thick in cement mortar 1:4 mixed with water proofing admixture as per manufacture's instruction on fair faces of brick work or cement concrete surfaces, finished even and smooth without using extra cement.
M&L for Rendering 15 mm thick in cement mortar 1:6, on fair faces of brick work or cement concrete surfaces, finished even and smooth without using extra cement.
M&L for Preparing new undecorated plastered or unplastered surfaces of ceiling and applying three coats of white wash
Preparing new undecorated plastered or unplastered surfaces of walls and applying three coats of white wash.
M&L for Preparing new plastered surfaces of walls and applying two coats of cement base paint over a coat of white wash.
Cement concrete, type C-2, 1:3:6 ( 40mm graded stone aggregate) 75 mm thick laid monolithically as in floors, pavement /path / plinth protection including use and waste of form work/screed strips and to divide the area in panels , finishing concrete topping even and fair ( without using extra cement ) , forming dummy joints etc.
M&L for 25mm thick PCC (1:2:4) type B1 by using 20 mm graded stone aggregate as in flooring including finishing the concrete surface smooth & even without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for 15mm thick Screed bed or bedding layer in cement mortar 1:4, thick for laying floor finishes.
M&L for Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) coloured, area of each tile exceeding 0.18 sqm but not exceeding 0.38 Sqm, of 1st quality conforming to IS-13755 set and jointed in neat cement slurry and pointed in coloured cement to match, laid over screed bed or bedding layer in cement mortar 1:6
All as per the description of item No. 56 but for work on vertical surfaces such as skirting, dados and riser to steps etc to match with the flooring set and jointed in neat cement slurry and pointed in coloured cement to match, including rendering 10 mm thick on fair faces or other than fair faces of brick work in cement mortar 1:4, finished even and fair as in backing layer..
M&L for Roughening surfaces of old concrete/terrazzo floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cemnt slurry 3.0 kg of cement per sqm..
M&L for 10mm thick rendering in cement mortar 1:4 to brick/concrete wall surfaces finished even & smooth (without using extra cement) with water proofing compound at the rate of 3% by weight of cement or as per the manufacturer’s instructions complete all as specified and directed by Engr-in-charge.
M&L for cleaning the roof surface thoroughly with wire brush, washed, dried up and cleaned of all foreign matter and dust to receive primer and apply one coat of approved bitumen primer at the rate of 0.25 to 0.30 ltrs per Sqm on the dried surface, on this primed surface the polymerized modified bituminous water proofing memberance with non woven polyester as reinforcement membrane with white gravel /mineral finished on upper side having weight at the rate of 3 Kg per Sqm & minimum thickness 3mm shall be laid by torch application method. The overlap while torching shall be 100mm on length side & 150 mm on width side of membranes as per manufacture instructions and as directed by Engr-in-charge.
S&F GI tubing 15 mm bore medium grade galvanised with all fitting and fixed to walls & ceilings or laid in floors complete all as specified and directed by Engr-in-charge.
S&F GI tubing 20 mm bore medium grade galvanise with all fitting and fixed to walls & ceilings or laid in floors complete all as specified and directed by Engr-in-charge.
S&F Stop Coke / Angle Valve cast copper alloy, chromium plated, screwed down, high pressure of size 15mm with crutch or butterfly handle, screwed both ends for iron pipe or for uniion of size 15mm bore all as specified and directed by Engr-in-charge.
S&F for Stop valves, cast copper alloy, chromium plated, fancy type, with long shank and cup concealed type of size 15mm with crutch or butterfly handle, screwed both ends for iron pipe or for uniion of size 15mm bore all as specified and directed by Engr-in-charge.
S&F Stop valves, cast copper alloy, chromium plated, fancy type, with long shank and cup concealed type of size 20mm with crutch or butterfly handle, screwed both ends for iron pipe or for uniion of size 20mm bore all as specified and directed by Engr-in-charge.
S&F of bib taps 15mm bore (for iron pipe) cast copper alloy with butter fly handle screwed down complete all as specified and directed by Engr-in-charge.
S&F brass chromium plated shower rose 125 mm of size with arm and with or without swivel joints to steel pipe or union complete all as specified and directed by Engr-in-charge.
S&Fof pillar tap 15mm bore dia cast copper alloy with cap capston chromim plated screwed down high pressure with or without lettered "Hot" or "Cold" with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and directed by Engr-in-charge.
S&F 10 ltrs capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve, float & handle including brackets complete all as specified and directed by Engr-in-charge.
S&F triple layer rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) of approved colour hoisted and jointed in position all as specified in SSR Part-I of 1000 ltr capacity providing all necessary fittings for connecting with pipe line, lockable cover complete all as specified and directed.
S&F 20 mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 20 mm - 210 grams) etc complete all as specified and directed by Engr-in-charge.
S&F vitreous china wash down water closet pan (pedestal pattern), white, 'P' or 'S' type, including 10 Ltrs PVC flushing cistern, low level, white, with inlet, ball valve, float & bracket including flush pipe, PVC tube 32mm dia & including plastic water closet seat, black, closed pattern with flat bottom, cover & MSCP or aluminium hinging device complete.
S&F vitreous China squatting pan of Orissa pattern of approved make of size 580 mm X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe including lime concrete bedding and connection to anti syphonage pipe etc including making good to floor complete all as specified and directed by Engr-in-Charge.
S&F vitreous china wash basin, white, flat back, size 550 mm x 400 mm fixed over and including cast iron cantilever brackets of 32 mm dia brass waste coupling and including fixing of waste fitting and union complete all as specified and directed by Engr-in-charge.
Vitreous China bowl urinal flat back, size 465x355x265 mm ( minimum ) white with grating and union for discharge pipe (including flush pipe and waste pipe ) as in repairs including making good the disturbed surface to match with the existing surface.
S&F Urinal partition slabs or dividing plate size 310 X 700 x 20mm mm vitreous china ware terminating about 40 cm above floor level lline and fixed top wall with steel screw & PVC rawel plug and making good the surface by white cement to match complete all as specified and directed by Engr-in-Charge
S&F 100mm dia cast iron soil waste pipe and vent pipes in any length with or without ears with cement joints laid in trenches or in floors complete all as specified and directed.
S&F 75mm dia cast iron soil waste pipe and vent pipes in any length with or without ears with cement joints laid in trenches or in floors complete all as specified and directed.
S&F PVC connection 15 mm size with PTMT nuts of length 600 mm of approved quality complete all as specified and directed by Engr-in-charge.
M&L for two coats of synthetic enamel paint to steel surfaces over one coat of red oxide primer including necessary preparation of new surfaces of any description over 10cm in width or girth complete all as specified and directed by Engr-in-charge.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing and as directed by Engr-in-Charge
S&F for 30 mm thick factory made solid panel PVC door shutter confirming to criteria of testing as per IS : 4020, consisting of frame made out of MS tube of 19 guage thickness & size 19x19mm for stiles and 15x15mm for top & bottom rails MS frames shall have a coat of red oxide primer of approved make and shall be covered with 5mm thick heat moulded PVC `C' channel of size 30x50mm forming styles and 5mm thick 75mm wide PVC sheets for top rail lock rail and bottom rail on either side and 10mm (5mmx2) thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail panelling of 5 mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rail with 30 mm wide x 5 mm thick PVC sheet beading on either side and joined together with solvent cement, adhesive and an additional 5 mm thick PVC strip of 20 mm width is to be struck on the interior side of 'C' channel using PVC solvent adhesive complete as per manufacturers specifications & drawings as directed by Engr-in-Charge.
S&F Aliminium anodised barrel tower bolts, 150 mm long complete all as specified and directed by Engr-in-charge.
S&F 100 mm mild steel cold rolled butt hinges and fixed complete all as specified and directed by Engr-in-charge.
S&F 125mm size extruded aluminium alloy handles, fabricated type anodized complete all as specified and directed by Engr-in-charge.
S&F pressed steel frames of size 105 X 60 mm for doors with one or more rebates including necessary fixing lugs hinges, locks strike plate etc. 1.25mm thickness of sheet and making good the wall with plaster in cement mortar 1:3 as required including filling the frames with PCC 1:2:4 type B0 by using 12.5 mm gradded aggregate complete all as specified and directed by Engr-in-charge.
S&F 2nd class HW 35mm thick local made panelled shutters with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, the size of rail and style shall be as per IS-1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed by Engr-in-charge.
S&F 150mm long oval type mild steel pressed handles stove enamelled black complete all as specified and directed by Engr-in-charge.
S&F 300 mm mild steel sliding bolt plate type stove enamelled black with bright bolt not less than 16 mm dia with and including a minimum of 6 bolts and nuts four on bolt plate and two on staple plate and fixed complete all as specified and directed by Engr-in-charge.
S&F in repair mild steel pressed handle 125 mm long oval types stove enamelled black complete all as specified and directed by Engr-in-charge.
S&F steel windows/ventilator with side hung shutters including projecting type hinges with steel handle & steel peg stay with glazing bars, dove tailed or welded including taking down the old window complete all as specified and directed by Engr-in-charge.
S&F 3 mm thick sheet glass of ordinary quality and glazing with oil putty in squares not exceeding 0.5 sqm in each pane complete all as specified and directed by Engr-in-charge.
M&L Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil.
M&L Sand filling under floor or in foundations including water and consolidation.
M&L Chequred cement concrete coloured , double layer ,heavy duty tiles conforming to IS : 13801: 2013 of size 20 cm x 20 cm x 25 mm thick, set, jointed and pointed in neat cement slurry with grey cement as in floors / pavements / paths laid over screed bed or bedding layer in cement mortar 1:4, 15 mm thick for laying floor finishes. NOTE : The tiles shall be of approved standard IS approved manufactured
M&L Stone Kerb of Roughly sqaured stones of size 20cm x 30cm x 10cm thick dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 6mm for top and exposed surfaces of sides and 20mm for the rest of surfaces jointed in cement mortar 1:5 and struck flush
M&L for providing plain cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in concrete bed to drain pipes of 150 mm bore including packing under & haunching against the sides of pipe after they are laid and tested complete all as specified and directed by Engineer-in-Charge.
M&L for 150 mm bore salt glazed stone ware drain pipes laid in trenches and jointed complete all as specified and directed.
M&L for providing Precast cement concrete 1:2:4 Type B1 as in cover slabs (for manholes etc) and similar articles with plain faces and set in cm 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for excavating over areas, not exceeding 1.5m deep and getting out hard / dense soil complete all as specified
M&L for excavating over areas, additional 1.5m deep or part thereof in depth beyond the first 1.5m and getting out soft / disintegrated rock
S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0 including dismantling of MS work complete all as specified and directed by Engr-in-Charge.
M&L for Cutting into existing man holes for connecting new drains, making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or ¾ in section) in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) smooth finished surface and reforming benching as required for internal dia of pipe 225 mm complete all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall (160mm bore) including flat iron clamp of size for proper fixing complete all as specified and directed by Engr-in-charge.
PVC (SWR) junction single (single T) equal or unequal provided with access door of 160 mm dia.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall (75mm bore) including flat iron clamp of size for proper fixing complete all as specified and directed by Engr-in-charge.
S&F PVC (SWR) junction single (single T) equal or unequal provided with access door of 75 mm dia.
M&L Dismantling timber scantling of any description, 40 sqcm and over in section, in any position as in framed work.
M&L Demolition of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets.
M&L Taking down chowkats or frames of any description (other than wooden chowkats) with shutters (without taking off shutter from the frames) not exceeding 1.5 Sq.m each.
S&F Transomes or Mullions, 2nd class hard wood straight, for solid frames of any description, wrought, framed , double rebated on the solid, rounded of chambered (including weathering to transome, if required put together with gule, pinned at joints) supplied and fixed
S&F 2nd class, hard wood, (suitable for joiner’s and carpenter’s work, locally available) as in scantling, wrought, timber framed and fixed.
S&F Factory made Flush shutters, solid core construction, 40 mm thick with block board core and ply wood face panels commercial type on both sides.
S&F Mild steel barrel tower bolt, stove enameled black, with bright bolt and fixed of size 200mm
S&F Anodized aluminium , powder coated, snap grid frame work of size 605 x 605 mm for false ceiling including necessary notching and preparing holes supporting hangers comprising of mild steel rod, ‘J’ bolt with necessary washer, bolts and nuts for securing frame work to ceiling and to the snap grid.
S&F Non asbestos cement plain building board, 6mm thick, fixed or laid / inserted to timber / GI/ Aluminium frame work in ceiling frame work as in ceiling.
S&F Plain, galvanised, mild steel sheeting, 0.80mm thick with 270gm/Sq.m of zinc coating, as in ridges, hips, valley gutters, drip and straight flashings fixed with galvanized L-hook or cranked bolts, 8mm dia with bitumen and G.I limpet washers filled with white lead complete.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint on wooden surfaces complete all as specified and directed by Engr-in-Charge.
Notes: The amount of Rs 7240/- against schedule of credit given on Tender Serial Page No 67 shall be deducted from the total amount quoted by the contractor against BOQ while deriving the contract sum for acceptance.
V r traders
M/S S.K.Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .