Loading…
Loading…
Tender Value
₹1.8 Cr
EMD Value
₹3.6 L
Closing Date
5 May 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnoverofV/N or 'V' whichever is less; where V= Advertised value of the tenderincrores of Rupees N=Number of years prescribed for completion ofwork forwhich bids have been invited.The average annual contractualturnovershall be calculated as an average of "totalcontractualpayments" in theprevious three financial years, as per theaudited balance sheet. However,in case balance sheet of the previousyear is yet to be prepared/ audited,the audited balance sheet of thefourth previous year shall be consideredfor calculating average annualcontractual turnover. The tenderers shallsubmit requisite informationasper Annexure-VIB, along with copies ofAudited Balance Sheets dulycertified by the Chartered Accountant/Certificate from CharteredAccountant duly supported by Audited BalanceSheet.
Audited Balance sheet as per above description along with informationasper Annexure-VIB (of GCC) to be enclosed.
(a) The tenderer must have successfully completed orsubstantiallycompleted any of the following during last 07 (seven) years,ending lastday of month previous to the one in which tender is invited:Threesimilar works costing not less than the amount equal to30%ofadvertised value of the tender, or Two similar works costing notlessthan the amountequal to 40% of advertised value of the tender, orOnesimilar work costing not less than the amount equal to 60%ofadvertised value of the tender. (b) (i) In case of composite works(e.g.works involving more than one distinct component, such asCivilEngineering works, S&T works, Electrical works, OHE works etc. andinthe case of major bridges substructure, superstructure etc.),tenderermust have successfully completed any of the following duringlast 07(seven) years, ending last day of month previous to the one inwhichtender is invited: Three similar works costing not less than theamountequal to 30% of advertised value of each component of tender, orTwosimilar works costing not less than the amount equal to 40%ofadvertised value of each component of tender, or One similarworkcosting not less than the amount equal to 60%of advertised valueofeach component of tender. Note: Separate completed works ofminimumrequired values shall also be considered for fulfillment oftechnicaleligibility criteria for different components.
The similar nature of the work is defined as: "Any work in connection with signaling installation. The work shall have indoor wiring component also if tendered work involves indoor wiring alteration in the existing system."
17 conditions · 3 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association /Board resolution, failing which tender shall be summarily rejected. Note:- Power of attorney on non-judicial stamp paper as per MP state stamp duty.
The tenderer shall clearly specify whether the tender issubmitted on his own (Proprietary Firm) or on behalf of aPartnership Firm / Company / Joint Venture (JV) / RegisteredSociety / Registered Trust / Hindu Undivided Family (HUF) /Limited Liability Partnership (LLP) etc. The tenderer(s) shallenclose the attested copies of the constitution of their concern,and copy of PAN Card along with their tender. TenderDocuments in such cases are to be signed by such persons asmay be legally competent to sign them on behalf of the firm,company, association, trust or society, as the case may be as follows
(a)Sole Proprietorship Firm: (i)All documents in terms of Para 10of the Tender Form (Second Sheet) of GCC.
The tenderer(s) shall enclose the attested copies of theconstitution of Fim.
(b)HUF: (i)A copy of notarized affidavit on Stamp Paper declaringthat he who is submitting the tender on behalf of HUF is in theposition of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to acton behalf of HUF. (ii)All other documents in terms of Para 10 ofthe Tender Form (Second Sheet).
The tenderer(s) shall theconstitution of Fim.
(c)Partnership Firm: (i)All documents as mentioned in para18 ofthe Tender Form (Second Sheet).
The tenderer(s) shall enclose the A notarized copy of 2.3.1 thePartnership Deed or a copy of the Partnership deed/partnershipfirm agreement registered with the Registrar.
2.3.2 Copy of PAN Card of partnership firm along with their tender.
A notarized or registered copy of Power of Attorney in favour 2.3.3 ofthe individual to tender for the work, sign the agreement etc.and create liability against the firm.
An undertaking by all partners of the partnership firm that theyare not blacklisted or debarred by Railways or any other Ministry/ Department of the Govt. of India from participation in 2.3.4 tenders /contracts as on the date of submission of bids, either in theirindividual capacity or in any firm/LLP in which they were / arepartners/members.
(d)Company registered under Companies Act2013: (i)The copiesof MOA (Memorandum of Association) / AOA (Articles ofAssociation) of the company.
(iii)A copy of Authorization/Power of Attorney issued by theCompany (backed by the resolution of Board of Directors) infavour of the individual to sign the tender on behalf of thecompany and create liability against the company.
(e)LLP (Limited Liability Partnership): (i)A copy of LLP Agreement
(iii)A copy of Power of Attorney/Authorization issued by the LLPin 2.5.2 favour of the individual to sign the tender on behalf of the LLPand create liability against the LLP.
Supply installation testing and commissioning of Signalling material in connection with Interlocking of LC Gates having ATVU above 10000. (3 Nos)
SnT_RTM_26_06_Signal
SnT_RTM_26_06_Signal
Open
Works - General
12 Months
Ratlam, Madhya Pradesh
₹0
₹3.6 L
5 May 2026
10 Apr 2026
21 Apr 2026
110 items across 4 schedules · ₹2,10,91,575.63 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of Remote Terminal Unit (RTU) with 128 digital input &16 analog input as per technical specification IRS: S-99 2006(Amdt-3) or latest. In addition RTU should have dual leased line modem. It should possible to connect RTU up to 12 Kms from main data logger. This includes rack for installation &Battery backup for 06 hrs.(Inspection by RDSO) | Numbers | 3.00 | 1,99,706.33 | 5,99,118.99 |
| 2 | Main Signal Post Tubular 140 mm Dia, 4.6 Mtr Length as per IRS: S-6/81 or Latest & RDSO Drg. No. SA-24625 (Advance). | Numbers | 16.00 | 8,199.23 | 1,31,187.68 |
| 3 | Supply Color Light Signal Accessories. ( Signal Post Tubular 140 mm Dia, 5.6 Mtr Length as per IRS: S-6/81 or Latest ) | Numbers | 14.00 | 10,895.41 | 1,52,535.74 |
| 4 | Non Metallic (FRP) color light signal housing multi-unit type for railway signaling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | Numbers | 16.00 | 28,577.72 | 4,57,243.52 |
| 5 | Non Metallic (FRP) color light signal housing multi-unit type for railway signaling suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol.1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | Numbers | 10.00 | 29,823.91 | 2,98,239.1 |
| 6 | Non Metallic (FRP) color light signal housing multi-unit type for railway signalling suitable for RE area FOUR Aspects. Complete without lenses, lamps and signal transformer as per RDSO Drg.No. SA 23001/A/M Adv. Alt- Sand as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. | Numbers | 4.00 | 33,303.86 | 1,33,215.44 |
| 7 | Miniature, Plug-in Type, DC Neutral Line, Non AC Immunized Relay, Style QN1, 24 V DC, 8F-8B/12F-4BContact, Code ABCDF/ABCDE Spec: BRS: 930; IRS S 34; IRS S 23. | Numbers | 90.00 | 4,284.48 | 3,85,603.2 |
| 8 | Miniature, Plug-in Type, DC Neutral Line AC Immunized Relay, Style QNA1, 24 V DC, 8F-8B/12F-4BContact, Code ABDGH/ABDFH Spec: BRS: 931A; IRS S 34; IRS S 23; IRS S 60-78. | Numbers | 105.00 | 5,576.04 | 5,85,484.2 |
| 9 | Relay, AC Immune, Plug-in-type, style "QNA1K" ACI DC Neutral line, 24V DC 1000 Ohms 6F.6B contacts, front contacts metal to carbon and back contacts metal to carbon. Complete with plug board, retaining clip and connectors confirming to IRS: S34, IRS: S23, BRS931A. As per RDSO Specification No. STS/E/Relays/UEA (PI) Dt.30/05/97. Annexure II. The interlocking pin code CDEKY. | Numbers | 30.00 | 5,525.31 | 1,65,759.3 |
| 10 | Universal AC ECR of Q series, type "QECX61" suitable for AC LED all signal aspect, Front & back contact Metal to Carbon type complete with plug board retaining clip & connectors conforming to Spec STS/E/Relays/AC Lit LED Signal/09/2002, BRS: 941A, IRS: S34 and IRS: S23 (as applicable). | Numbers | 336.00 | 5,613.1 | 18,86,001.6 |
| 11 | Key Lock Relay working on 24V DC, AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer incharge as per requirement. | Numbers | 12.00 | 9,743.97 | 1,16,927.64 |
| 12 | Fail Safe Electronic Flasher device for Railway Signaling operate on 24V DC/110V AC (as per site requirement) with over voltage protection 50-60 flashes per minute and as per RDSO specification No. RDSO/SPN/173/2002 (Amd. 1) or Latest. | Numbers | 3.00 | 10,360 | 31,080 |
| 13 | Relay racks assembly complete with scaffolding bus bars, fuse strips, fuses, resistors, capacitors, insulators, grouting bolts, tripods etc. as per Drg. No. CSTE /6028 .[Scaffolding should include 20% extra (with minimum of 2 relay rack positions) as spare for future expansion]. Relay rack shall be Powder Coated. (Quantity of Resistance, capacitor & Other items as Annexure.) | Numbers | 3.00 | 26,249.42 | 78,748.26 |
| 14 | Cable termination racks as per Drg. no. CSTE 5004, 5005, 5006 complete along with fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated. | Numbers | 3.00 | 24,008.12 | 72,024.36 |
| 15 | Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63 A - 3.0 A. (System, Rapid, Malnad or RBCO make or similar). | Numbers | 180.00 | 18.6 | 3,348 |
| 16 | Indicative type Fuse base/ holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar). | Numbers | 120.00 | 50.99 | 6,118.8 |
| 17 | Cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4 & Spec No IRS S 75/2006 with the latest amendment. The fuse block shall be suitable for round- head type voltage fuses. This also includes the supply of equivalent no of ND type Fuses of 2A capacity as per specification IRS S-78/92. | Numbers | 75.00 | 129.41 | 9,705.75 |
| 18 | Round head type non deteriorating type low voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 2A/4A/6A capacity. | Numbers | 180.00 | 57.21 | 10,297.8 |
| 19 | Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 24 nos. of external Non- Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signaling circuits. The system shall have 6 cards with a monitoring arrangement of 4 fuses in one card. | Each Module | 6.00 | 51,953.78 | 3,11,722.68 |
| 20 | Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply. | Numbers | 900.00 | 58.53 | 52,677 |
| 21 | Supply of End plate 2.5mm/0.091 in thick as per site requirement. | Numbers | 94.00 | 11.07 | 1,040.58 |
| 22 | Supply of End Stopper 10mm/0.0394 in width as per site requirement. | Numbers | 113.00 | 10.86 | 1,227.18 |
| 23 | Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. | Numbers | 30.00 | 113.88 | 3,416.4 |
| 24 | Supply of 4 connection points single potential through screw less terminal block for 6 Sq.mm - 35 Sq.mm , 4 connection points 284-621/624 or superior, suitable for power cable connection. | Numbers | 90.00 | 270.84 | 24,375.6 |
| 25 | Earth Electrode as per Drg. No. CSTE / 6091. | Numbers | 30.00 | 2,798.99 | 83,969.7 |
| 26 | Supply of Fiber/ SMC/FRP/RCC Earth Chamber. | Numbers | 30.00 | 649 | 19,470 |
| 27 | ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA- 23741A Alt.4. | Numbers | 1200.00 | 75 | 90,000 |
| 28 | Apparatus Case Single NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A, fitted with two no.s of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377 Note: This item includes the supply & fixing of 2 No.s E Type Lock fitted on both doors, along with two Keys. | Numbers | 18.00 | 15,611.07 | 2,80,999.26 |
| 29 | Apparatus Case half NE Rly Type as per Drg. No. W. Rly/SW/47/68 Alt-A fitted two no.s E Type lock of (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376/3473 and Key to Drg. No. 3377. Note: This item includes the supply & fixing of 2 No.s E Type Lock fitted on both doors, along with two Keys. | Numbers | 18.00 | 9,893.99 | 1,78,091.82 |
| 30 | IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet : 1000x1000x8 | Numbers | 18.00 | 5,388.67 | 96,996.06 |
| 31 | PPVC insulated Railway Signaling multi- core Indoor Cable 1mm x 24 mm x 1 mm Dia conforming to IRS:76/89(Amd3) or latest. | Kilometre | 0.60 | 1,83,153.7 | 1,09,892.22 |
| 32 | PVC insulated Railway Signaling multi-core Indoor Cable 1 mm x 40 mm x 0.6mm Dia conforming toIRS:76/89(Amd3) or latest. | Kilometre | 1.50 | 92,180.73 | 1,38,271.1 |
| 33 | Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest. | Kilometre | 6.00 | 5,548.54 | 33,291.24 |
| 34 | Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm.( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest. | Kilometre | 0.45 | 33,366.21 | 15,014.79 |
| 35 | Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest. | Kilometre | 0.60 | 1,36,063.55 | 81,638.13 |
| 36 | Flexible cable (Power wire), multi-strand copper conductor's cross section 25 Sq. mm (0.4x196) as per specn. IS 694/2010 with latest amendment, and test parameters as per IRS(S) 76/89. | Kilometre | 0.45 | 1,32,505.12 | 59,627.3 |
| 37 | Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. . One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identifi e d. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer. | Numbers | 18.00 | 1,912.2 | 34,419.6 |
| 38 | Medium Class G.I. Pipes to IS: 1239 (Pt.)- 2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes. | Running Metre | 180.00 | 1,170.28 | 2,10,650.4 |
| 39 | Electrically Operated Lifting Barrier complete set suitable for 110VDC/24V DC supply with hand generator back up & motorized boom locking arrangements as per RDSO Spec. SPN/208/2012 with the latest amendment. One set consisting of 02 No.s of Barriers of length 09.76 Mtr. along with Spares & tool kit mentioned in RDSO Spec. SPN/208/2012 clause 10.1 & 10.2. | Set | 3.00 | 4,69,571.95 | 14,08,715.85 |
| 40 | MS Sliding type mechanical Boom barrier assembly 11 to 12 Meter Long, movement drive mechanism, resetting & supporting stand suitable for Mechanical/ Electrical level crossing gate as an emergency arrangement as per Drg. | Set | 3.00 | 1,44,275.33 | 4,32,825.99 |
| 41 | Road warning Flasher kit for LC gate as per circuit design | Set | 3.00 | 1,665.03 | 4,995.09 |
| 42 | Digital Multimeter of Fluke 287 Industrial, True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 seconds or Superior. | Numbers | 3.00 | 44,774.52 | 1,34,323.56 |
| Schedule total | ₹89,30,290.93 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tenderdocument3lc.pdf
ATTACHMENT
Appendix3lc.pdf
ATTACHMENT
GCC_April-2022_1.pdf
ATTACHMENT
GCCACS.pdf
ATTACHMENT
ACS-2toGCC-2022.pdf
ATTACHMENT
GCCApril2022ACSNo_3_1.pdf
ATTACHMENT
GCCApril2022ACSNo_4.pdf
ATTACHMENT
GCCApril2022ACSNo_5.pdf
ATTACHMENT
GCCApril2022ACSNo_6.pdf
ATTACHMENT
GCCApril2022ACSNo_8.pdf
ATTACHMENT
GCCApril2022ACSNo_9.pdf
ATTACHMENT
GCCApril2022ACSNo_10.pdf
ATTACHMENT
GCCApril2022ACSNo_7.pdf
ATTACHMENT
revisedTANearthingHQletter040725_1.pdf
ATTACHMENT
GCCApril2022ACSNo_11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .