Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹9.3 L
Closing Date
19 Jun 2024, 11:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Karnataka Power Transmission Corporation Limited
Sushma
Supply, Installation, Wiring, Testing & Commissioning of Data Concentrator Units (DCU) with existing IF point Energy Meters in KPTCL Substations for establishing Automatic Meter Reading (AMR) solutions in Karnataka
KPTCL/2023-24/SS/WORK_INDENT337/CALL-2
KPTCL/2023-24/SS/WORK_INDENT337/CALL-2
Open
Sub-Station
Two Tender Document System(Two Cover)
KPTCL CEE Corporate Office SLDC Bengaluru
13 documents required · 9 mandatory · 4 optional
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
List of Financial Resources with Certificates
The bidder should be Original Manufacturer/Authorized Dealer of the original manufacture of Data Concentrator Units (DCU)/AMR AMI/IOT devices and should have supplied, installed and commissioned minimum 10000Nos. of DCUs/AMR/IOT/AMI devices for Automatic Meter Reading solution (AMR) across any Power utilities/government agency in India and should be successfully working as on the date of bid submission. (Bidder shall upload the PO/Work Award copies and Performance & Working certificate of the same work). In case of bidder is authorized Dealer, such authorized dealers should furnish a letter from their manufacturer certifying that they are the authorized Dealer of the manufacturer. The authorized Dealer of the manufacturer shall furnish a legally enforceable deed of undertaking to guarantee quality, timely supply and performance and warranty obligations as specified in the contract
The Original Manufacturer/Authorized Dealer should have successfully executed at least Two Projects covering the work of: Supply, Installation, Commissioning and Integration with Centralized DCU Monitoring & Management System (or HES), Operations & Maintenance of DCUs/AMR/IOT/AMI devices in Power utilities/ Government Agency in India (Bidder shall upload the PO/Work Award copies)
The Original Manufacturer/Authorized Dealer should have orders for at least Three Software Application related Projects which should be hosted in a Data Centre/Cloud for any Government agency (Bidder shall upload the PO/Work Award copies).
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
The bidder should have Goods and Service Tax (GST), ESI, EPF, PAN/TAN registration and shall upload the necessary supporting document to establish compliance for having the said registration
The bidder must be registered in India under the Companies Act 1956/2013 from past 3 years from the date of this Bid (Bidder shall upload the supporting documents) and The Bidder should possess the following certificates as on the date of the tender (Copies of the certificates shall be uploaded). (a) ISO 9001:2015 QMS (b)ISO 27001:2013 (c)ISO 20000-1:2018 IT service Management system
The Bidder should possess the CMMI Level-5 Development Certification as on the date of bid and shall upload the necessary supporting documents (Refer Clause-45 of ITB)
The Technically Responsive bidder shall arrange for a Presentation and Demonstrate Local & Remote Data Transfer process and Centralized DCU Monitoring & Management Software as per the specification at their own cost at a suitable place indicated by the tendering authority. The responsive bidder shall arrange for Energy Meter, DCU and system for monitoring the DCUs at their own cost for Proof of Concept (PoC). Only such of the bidders successfully demonstrating this capability will be considered for further evaluation
The Financial Capability corresponding to bidders highest Annual Turnover in at least two financial years in the preceding Five(5) Financial Years, shall not be less than 50Crores. The bidder shall upload the audited Annual Financial Turnover Certificate along with the Profit & Loss Statement, Balance sheet for the preceding Five(5) Financial years duly certified by a Chartered Accountant
The bidder shall furnish Type Test Certificate not older than Five years as on the date of bid opening for having conducted successful Type Test in any independent laboratories approved by Government or NABL accredited test house like ERDA/CPRI/NPL/ERTL/ NABL laboratory on the DCU/AMR devices as required for executing the scope of work as per the bid document. In case, KPTCL desires any other type test certificate on the equipment proposed to be used by the bidder, the bidder shall give an undertaking agreeing to conduct all type tests on the 1st Unit at any independent laboratories approved by Government or NABL if order is placed on the firm without affecting the Delivery Schedule and at no extra cost to KPTCL
The Bidder should not have been blacklisted by any State/Central/Generating/Transmission Utility as on the date of bid submission. The bidder shall upload a declaration in this regard and non-furnishing of the declaration will result in rejection of the Bid
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years with KPTCL. A history of awards involving litigations against the bidder or any part or JV may result in rejection of bid. Bidders should furnish the self-declaration stating the above and upload the same along with the other documents in the relevant filed in the e-procurement portal, failing which the offer is liable to be rejected
The Bidder shall upload the Power of Attorney in the prescribed format for(Authorized Signatory) on Rs.500/- stamp paper. Further the original hardcopy shall be posted to The Chief Engineer Electy., SLDC, KPTCL, No.28, Race Course Cross Road, A.R.Circle, Bengaluru-560 009, so as to reach after the last submission date & on or before the date & time of opening Techno commercial Bids
₹5,000
₹9.3 L
14 Mar 2024
14 Mar 2024
21 Jun 2024
20 Mar 2024
21 Mar 2024
Supply, Installation, Wiring, Testing & Commissioning of Data Concentrator Units (DCU) with existing IF point Energy Meters in KPTCL Substations for establishing Automatic Meter Reading (AMR) solutions in Karnataka
Data Concentrator units (DCU) with 4 No of serial Ports, 2 Ethernet ports, Universal power supply range capable of connecting to minimum 20 numbers of DLMS Energy meters
Centralized DCU Monitoring & Management software: Server for monitoring of DCU data at Control Center
Centralized DCU Monitoring & Management software: Software for configuration of DCU at Control Centre
10 Core 0.5Sqmm Armoured Copper Communication Cables (150Mtrs/Station)
Miscellaneous materials (DCU fixing & wiring materials)which includes Din Rail channel, Nuts, Bolts, Lugs, Cable Ties, Terminal Blocks, supply cable (2.5sqmm) with suitable MCB control for the supply ...
Integration charges
AMC for 5years (Amount Per year, per station for 5Yrs)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT_DCU_IF point_(CALL-2).docx
Others - Notification • 0.10 MB
undertaking formats.docx
Others - Undertaking Formats • 0.02 MB
Techno-Commercial Schedules (GTP)_DCU (1).xlsx
Techno-Commercial Worksheet • 0.04 MB
ITB_DCU_IF point_(CALL-2).docx
Instructions to Tenderers • 0.07 MB
POWER OF ATTORNEY format.doc
Others - POA Format • 0.03 MB
IFB_DCU_IF point_(CALL-2).docx
Others - Information to Bidders-IFB • 0.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .