Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 CrAccepted-AOC 723 27 SHIVAJINAGAR SUDHARSHAN NIWAS NEAR POLICE GROUND BARSHI SOLAPUR 413 411 | BARSHI | SOLAPUR | MAHARASHTRA | 413411 | ₹42.8 Cr Quoted ₹42.4 Cr | L1 | Accepted-AOC 1st Lowest |
| 2 | Rejected-Technical S NO 23 2 GROUND ANAND VIHAR COLONY SINHAGAD ROAD HINGAHE KHURD PUNE CITY PUNE MAHARASHTRA 411051 INDIA | PUNE | MAHARASHTRA | 411051 | - | - | Rejected-Technical As per report |
| 3 | Rejected-Technical | - | - | Rejected-Technical As per report |
Tender Value
Refer Docs
EMD Value
₹38.4 L
Closing Date
2 Mar 2021, 3:00 pmClosed
Managing Director
Plot No.R-7, MarketYard, Gultekadi, Pune 411037
CW6 Erection of New Facility Centre at Baramati, District Pune
2021_CMTAD_635233_1
MSAMB/ENGG/ADB/MAGNET/CW6
Open Tender
Civil Works - Others
365 days
Baramati, District Pune
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
₹38.4 L
Yes
Maharashtra State Agricultural Marketing Board
24 Sept 2021
12 Jan 2021
2 Mar 2021
12 Jan 2021
2 Mar 2021
4 Feb 2021
12 Jan 2021 - 21 Jan 2021
27 Jan 2021
Civil Work
Road Work
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed. (SSR2019-20, Item no.2.11, Page no.26, Additional specification MORTH 301)
Supplying hard murum/ kankar at the road site, including conveying and stacking complete. (SSR2019-20, Item no.2.29a, Page no.29, Additional specification MORTH 408)
Spreading hard murum/ soft murrum/ gravel or kankar for side width complete . (SSR2019-20, Item no.2.30, Page no.29, Additional specification MORTH 408)
Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete. (SSR2019-20, Item no.2.31, Page no.29, Additional specification MORTH 408)
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc complete. (SSR2019-20, Item no.21.40, Page no.201, Additional specification Bd.A.12 Page No. 264)
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with vibratory roller to the required density. By Mechanical Means - Grading II (Using Screening Type B (11.2 mm) Aggregate) (SSR2019-20, Item no.3.20, Page no.34, Additional specification MORTH 404)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc (SSR 2019-20, Item no.24.01, Page no.226, Additional specification Bd.E.1 Page No. 287)
Providing and laying 125 micron Low Density Polyethylene (LDPE) sheet confirming to IS 3395 : 1997 below concrete pavement including all materials and labour complete. (SSR2019-20, Item no.5.19, Page no.51, Additional specification RD)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (SSR 2019-20, Item no.26.33, Page no.245, Additional specification Bd.F.17, Page No.306)
Providing and laying in situ cement concrete M -30 with tremix treatment for 200 mm thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of4 mm wide and 20 mm deep with necessary refilling with bitumen (excluding reinforcement) with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) etc. complete. (SSR2019-20, Item no.5.19, Page no.51, Additional specification RD)
Conveying materials obtained from road cutting including all lifts, laying in layers of 20cm to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50m to 300m. inclusive from the site of excavation to the site of deposition as directed. (SSR2019-20, Item no.2.25, Page no.28, Additional specification MORTH 305)
Building Work
Dressing of side shoulder / Scrapping the road side shoulder by Mechanical means ( By JCB /DOUZER) including excavation of raised side shoulders upto 15cm depth including remooving /cutting bushes,grass and dressing shoulder to desired camber and disposing of excavated stuff up to road boundary etc complete. as directed by Engineer In Charge. (SSR2019-20, Item no.8.23, Page no.97, Additional specification As directed by engineer incharge)
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.)Bd.A.1 Page No.259
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Bd.A.2 Page No.259
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical Means Bd.A.3 Page No.259
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means (SSR2019-20, Item no.21.14, Page no.198, Additional specification Bd.A.2, Page No.259)
Excavation for foundation in Hard rock by blasting including trimming and leveling the bed by chiseling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum, watering, ramming, etc. complete. (Lift upto 1.5m) By Mechanical Means (SSR2019-20, Item no.21.16, Page no.198, Additional specification Bd.A.5 Page No.259)
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift upto 1.5 m). By Mechanical Means (SSR2019-20, Item no.21.20, Page no.199, Additional specification Bd.A.6 Page No.260)
Providing soling using 80 mm size trap metal in 20 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete
Filling in plinth and floors with approved excavated material in 15cm to 20cm including watering and compacting etc. complete.
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15cm. to 20cm. including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263
Conveying materials obtained from road cutting including all lifts, laying in layers of 20cm to 30cm. breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97%of standard Proctor density for a lead of over 50m. to 300m. inclusive from the site of excavation to the site of depositionas directed. I.No.2.26, Page No.28
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. As Directed by Engineer Incharge
Providing preconstructional antitermite treatment as per I.S. 6313 (PartII) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 0.5 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. ( AS per Item no. 22.43 of schedule of rates of NBO ) As directed by Engineer in charge.
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2019-20, Item no.24.01, Page no.226, Additional specification Bd. E. 1 Page No. 287)
Providing and laying Cast in situ/Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate ( Natural Sand / Crushed sand VSI Grade finely washed etc. ) Spec. No. Bd.E.1 Page No. 287 (SSR 2019-20, Item no.24.04, Page no.226, Additional specification Bd.E.2 Page No. 288 and B.7 Page No 38)
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.E. 3/Page No. 288/I.S. 456 (2000 (S. S. R. I. No. 24.16 & Page No. 221) for first floor
Providing and laying in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC withnSCADA enabled reversible Drum Type mixer/ concrete Batchn mix plant (Pan mixer) etc. complete. With natural sand/V.S.I.quality Artificial Sand (SSR 2019-20, Item no.25.11, Page no.230, Additional specification Bd.F.3 Page No. 298 and B.7, Page No.38)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2019-20, Item no.25.13, Page no.230, Additional specification Bd.C.12 Page No. 275)
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). (SSR 2019-20, Item no.25.15, Page no.231, Additional specification Bd.C.12 Page No. 275)
Providing and laying Cast in situ/Ready Mix cement concrete M- 20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand (SSR 2019-20, Item no.25.31, Page no.232, Additional specification Bd.C.12 Page No. 275)
Providing and laying Cast in situ/Ready Mix cement concrete M- 25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping,compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand (SSR 2019-20, Item no.25.33, Page no.233, Additional specification Bd.Bd.F.5 Page No. 300 and B-7,Page No 38.)
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2019-20, Item no.25.33, Page no.233, Additional specification No. Bd.F.5 Page No. 300 And B7, Page No 38.)
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2019-20, Item no.25.35, Page no.233, Additional specification Bd.E.2 Page No. 288 and B.7 Page No 38) for first floor
Providing and laying Cast in situ/Ready Mix cement concrete M- 20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping,compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand (Compound Wall) (SSR 2019-20, Item no.25.50, Page no.234, Additional specification Bd.F.6 Page No. 300 and B.7, Page No.38)
Providing and laying Cast in situ/Ready Mix cement concrete M- 25 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/pumping,compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand (Weighbridge) (SSR 2019-20, Item no.25.52, Page no.235, Additional specification Bd.F.6 Page No. 300 and B.7, Page No.38)
Providing and laying Cast in situ / Ready Mix cement concrete in M-30 of trap / granite / quartzite / gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2019-20, Item no.25.54, Page no.235, Additional specificationSpec. No. Bd.F.6 Page No. 300 and B.7, Page No.38)
a) Ground Floor
b) First Floor
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap / granite / quartzite / gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.9 Page No. 303 and B.9, Page No.38
a) Ground Floor
b) First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc (SSR 2019-20, Item no.25.72, Page no.236, Additional specification Bd.F.8 Page No.302 and B.7, Page No.38)
a) Ground Floor
b) First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.8 Page No. 302 and B.7, Page No.38
Providing and laying Cast in situ / Ready Mix cement concrete M-25of trap / granite / quartzite / gneiss metal for R.C.C. waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, laying / pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block). (Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With Natural Sand / V.S.I. Quality Artificial Sand. Spec. No. : Bd.F. 13 Page No. 305. /I.S. 456 (2000)
a) Ground Floor
b) First Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete.(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
a) Ground Floor
b) First Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations,slabs, beams columns, canopies, staircase, newels, chajjas,lintels pardis, copings, fins, arches etc. as per detailed designs,drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete
Providing and fixing in position TMT FE 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. a) For TMT Fe 415 steel bars ( If Mild Steel/HYSD steel is to be used prior permission from S.E. should be taken )Bd.F.17, Page No.306 for first floor
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. (SSR 2019-20, Item no.23.01, Page no.223, Additional specification Bd.C.12 Page No. 275)
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc.Bd.G. 1 Page No. 313
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete.Bd.G.5 Page No.315
a) Ground Floor
b) First Floor
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall includingmmild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete.
a) Ground Floor
b) First Floor
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625 X 240 X 230 / 150 mm ) thick in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete. Spec. No. As Directed By Engineer In Charge.(For Weighbridge ) (S. S. R. I. No. 29.05 & Page No. 251)
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear)BD-T-55 Page No.510
Providing and fixing Chicken Mesh Of 22 Gauge, With About 30 Cm. Width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / B.B.masonry and or tying by binding wire etc. complete.As directed by Engineer in Charge:
a) Ground Floor
b) First Floor
Providing internal cement plaster 20mm thick in single coat in cement mortar 1:3 without neeru finish to stone masonry surfaces, in all positions including scaffolding and curing etc. complete. Spec. No. Bd.L.3 Page No. 368 (S. S. R. I. No. 32.08 And Page No. 268) For Below Texture Plaster (Weighbridge)
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Bd. L.2 Page No.368
a) Ground Floor
b) First Floor
Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:4 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete.
a) Ground Floor
b) First Floor
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.
a) Ground Floor
b) First Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. Weighbridge Spec.No. : As Directed By Engineer In Charge. (I. No. 32.34 & Page No. 264)
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.Bd.L.7 Page No. 369
a) Ground Floor
b) First Floor
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. (SSR 2019-20, Item no.32.21, Page no.269, Additional specification As directed by Engineer in charge.)
Providing and applying a base coat comprising of 1 Kg Polydee-MC and 1 Kg fresh cement after wetting the surface followed by drying the surface for 2 days, apply primer coat of TP-40 and after drying, applying Polydee-11 two component (mixing ratio 2 A : 1 B) ) Antibacterial food grade coating inside drinking water tank in two coats with time interval of minimum 8 hrs covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete. (SSR 2019-20, I.No.31.11, P.No.265. Additional Specification As directed by Engineer in charge.)
Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 32.32 And Page No. 263)
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Spec. No. Bd.U.1 Page No. 537 for ground floor
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Spec. No. Bd.U.1 Page No. 537 for first floor
Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean. Applying Asian / Berger / Nerolac / Duuex Paints or equivalent wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. Applying Asian / Berger / Nerolac / Dulex Paints or equivalent Acrylic wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applying Asian / Berger / Nerolac / Dulux Paints or equivalent wall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, Applying Asian / Berger / Nerolac / Dulux Paints or equivalent interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat of Asian / Berger / Nerolac / Dulux Paints or equivalent interior wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) for ground flor
Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean. Applying Asian / Berger / Nerolac / Duuex Paints or equivalent wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. Applying Asian / Berger / Nerolac / Dulex Paints or equivalent Acrylic wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applying Asian / Berger / Nerolac / Dulux Paints or equivalent wall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, Applying Asian / Berger / Nerolac / Dulux Paints or equivalent interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat of Asian / Berger / Nerolac / Dulux Paints or equivalent interior wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) for first floor
Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete. (SSR 2019-20, Item no.35.23, Page no.288, Additional specification As directed by Engineer in charge. ) for watchman cabin
Providing and applying Priming Coat on Concrete / Masonry / Asbestos Cement/ Plastered Surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required.As directed by Engineer in charge. for ground floor
Providing and applying Priming Coat on Concrete / Masonry / Asbestos Cement/ Plastered Surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required.As directed by Engineer in charge. for first floor
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. For panel room
Providing and applying two coats Apex Ultima Puranature Anti- Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the conceforrned company technologist.As directed by Engineer-in-charge for ground floor
Providing and applying two coats Apex Ultima Puranature Anti- Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist.As directed by Engineer-in-charge for first floor
Providing and applying Plastic Emulsion Paint Of Approved Quality, Colour And Shade To New Surface In Three Coats including scaffolding, preparing the surface. (excluding primer coat) etc. complete. Spec. No. Bd.P.6 Page No.414. & Preapproval of Superintending Engineer. Weighbridge (S. S. R. I. No. 36.14 & Page No. 285) for weigh bridge cabin
Providing and applying Two Coats Of Exterior Acraylic Emulsion Paint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. Spec. No. As directed by the engineer in charg. Weighbridge (S. S. R. I. No. 35.25 & Page No. 283) for weigh bridge cabin
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete.Bd.O.5 Page No. 405 for ground floor
Providing and fixing welded mesh of 11 gauge wires having mesh size 50 mm x 25 mm including M.S Angle frame of size 35 mm x 35 mm x5 mm in position with oil painting 3 coats etc. complete As directed by Engineer in charge. For ground floor
Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete.As directed by Engineer in charge for ground floor
Providing and laying in situ cement concrete M30 with tremix treatment for 200mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete. Spec. no. As directed by Engineer in charge (S. S. R. I. No. 33.31 & Page No. 277) for weigh bridge
Providing & applying of a 4 Component, Single Layer Seamless Solvent Free, Moisture Intensive and Epoxy Flooring 3mm thick system of density more than 1950 Kg/Cu.mtr to have a smooth & even matt finish matching below mentioned performance properties: 1- Mixed density more than 1900kg/Cu.mtr. 2- Abrasion resistance class of AR 0.5 as per BS 8204-2. 3- Cleanable to standards of stainless steel. 4- Zero absorption as per CP. BM 2/67/2. 5- Static Modulus of Elasticity of 3.3 X 10^3 MPa and Toughness of 96.7 X 10^3 Mpa as per modified ASTM C469/C469M. 6- Coefficient of thermal expansion of 3.6 X 10^-5 /oC as per ASTM C531. 7- Shore D hardness of 80. 8- Tensile strength of > 7Mpa. 9- Flexural strength of 20Mpa. 10- Adhesion to concrete of more than 2Mpa or until concrete fails. 11- Slip resistance classification 35 as per EN 13036-4. 12- Fire resistance classification of Bfl-S1 as per EN 13501-1:2002. 13- Surface spread of flame of CLASS 2 as per BS476, Part7. 14- Cure time of 12 Hours for foot traffic and 24 hours for vehicular traffic at 30oC. Applied at a thickness of 3mm over a 1mm scartch coat of the same material by an authorised applicator of the manufacturer in accordance to the application guidline as provided by the manufacturer. Spec. No. as Directed by Engineer In Charge. (Non SSR ) for ground floor
Providing and laying in situ cement concrete M20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20mm deep with necessary refilling with bitumen etc. complete.As directed by Engineer in charge (I.N0.33.30 P.N0.277)
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bedof 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring Spec. No. Bd.M.12 Page No. 385. (S. S. R. I. No. 33.40 & Page No. 271) for ground floor
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bedof 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring Spec. No. Bd.M.12 Page No. 385. (S. S. R. I. No. 33.40 & Page No. 271) for first floor
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1: 4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.b) Skirting (S. S. R. I. No. 33.41 & Page No. 271) for first floor
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1: 4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.b) Skirting for ground floor
Providing and fixing machine cut machine polished 18 mm to 20 mmthick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with full moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc complete (Ground Floor)
a) Ground Floor
b) First Floor
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete Spec. No .BDM-22, Page No. 390 (S. S. R. I. No. 33.18 & Page No. 276) - Weighbridge
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish for first floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec. No .As directed by Engineer-In- Charge (S. S. R. I. No. 33.68 & Page No. 275) For Door Frames for first floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec. No .As directed by Engineer-In- Charge (S. S. R. I. No. 33.68 & Page No. 275) For Door Frames for first floor
Providing and preparing kitchen otta up to 75 cm width,made up from 30 mm thick and 75 cm high vertical support for kadppa at 1 m c/c of 25 mm thick both side polished kadappa middle shelf and bottom of 20 mm thick one side polished kadappa with facia patti of 20 x 50 mm kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. for first floor
Providing and laying Polished Kota stone flooring With Hand-Cut Polished Kota Stones 25mm to 30mm thick and required width in plain/diamond pattern on bed of 1:6 Cement mortar including cement float, filling joints with neat cement slurry, curing, cleaning and Mirror Polishing etc. complete Note- Water absorption for kotastone should not exceed 0.05%.( Item to be used with prior permission of Superintending Engineer ) (SSR 2019-20, Item no.33.75, Page no.283, Bd. M-3 page No. 380 for first floor
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. (SSR 2019-20, Item no.33.81, Page no.284, Additional specification As directed by engineer incharge ) (SSR 2019-20, Item no.33.75, Page no.283, Bd. M-3 page No. 380 )for first floor
Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. Spec. No. Bd.M. 12 Page No. 385. (S. S. R. I. No. 33.24 & Page No. 276)
a) Ground Floor
b) First Floor
Providing and laying ceramic tiles having size 30 cm. x 45 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. complete. Spec. No. Bd.M.13 Page No. 386.. (S. S. R. I. No. 33.26 & Page No. 276)
a) Ground Floor
b) First Floor
Providing and fixing machine cut mirror polished 18 mm to 20 mm thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc. complete . Both side polish for ground floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec. No .As directed by Engineer-In- Charge (S. S. R. I. No. 33.68 & Page No. 275) For Door Frames
a) Ground Floor
b) Ground Floor
Providing and laying Polished Kota stone flooring With Hand-Cut Polished Kota Stones 25mm to 30mm thick and required width in plain/diamond pattern on bed of 1:6 Cement mortar including cement float, filling joints with neat cement slurry, curing, cleaning and Mirror Polishing etc. complete Note- Water absorption for kotastone should not exceed 0.05%.( Item to be used with prior permission of Superintending Engineer ) - Panel Room (SSR 2019-20, Item no.33.75, Page no.283, Bd. M-3 page No. 380 )
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. (SSR 2019-20, Item no.33.81, Page no.284, Additional specification As directed by engineer incharge ) - Panel Room
Providing and laying Antiskid Ceramic tiles of approved quality of size 30cmx 30cm and confirming to IS 15622-2006 (Group-BIIA)for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.-Watchman Cabin
Providing and laying ceramic tiles of having size 30cm.x 30cm. and confirming to corresponding I.S. for dado and skirting in required position with ready made adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/colour cement slurry cleaning curing etc. complete. -Watchman Cabin
Providing and preparing kitchen otta up to 75 cm width,made up from 30 mm thick and 75 cm high vertical support for kadppa at 1 m c/c of 25 mm thick both side polished kadappa middle shelf and bottom of 20 mm thick one side polished kadappa with facia patti of 20 x 50 mm kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc.
Providing 25 mm To 30 mm Thick Partition Of Polished Black Kadappa Stone Slab of approved quality including giving required size and shape etc. Fixing in cement mortar 1:3 curing and cement etc. complete. b) Both Side Polish. -Weighbridge Spec. No. Bd.M.35 B /P No.393 ( S. S. R. I. No. 33.33 And Page No. 270)
Providing and fixing heavy duty interlocking concrete Grey paving blocks of 80mm thickness of having a strength of 300kg/Sq.cm. of approved quality and shape on a bed of crushedsand of 25 to 30mm thick including skirting joints and cleaning etc. complete. Spec. No. As directed by engineer incharge.
Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards ,screwed/ fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25x 50mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from under side to give smooth, seamless ceiling. The rate should include necessary additional ceiling section sand inter mediate channels. Additional intermediate channels should be fixed to straphangers for additional support to prevent strapping at every 1200milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cutouts, painting including labour, material, lifts etc. all complete.
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k= 0.052-0.057w/mK, Colour White, Fire Performance UK Class 0/ Class1 (BS 476 pt-6&7) in module size of 600x600x20mm, suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I. channel on XL 2 Clip having a web height of 32mm with 15mm wide T-section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200mm and 600mm Cross Tees with a web height of 32mm and a load carrying capacity of 7.7Kgs/M2 and minimum pull out strength of 100Kgs.. The T Sections have a Galvanizing of 90grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Spec as directed by engineer in charge.
Providing and fixing 900mm high S.S. 304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compoundand laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 31.04 & Page No. 263
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 22.19.1 3 mm thick ( CPWD D.S.R. 2015-16 w.e.f July-2016 I. No. 22.19 & Page No. 385 ) For Terrace
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqm /kg with two coat using approved chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete. (SSR 2019-20, Item no.31.09, Page no.264, Additional specification As directed by engineer incharge)
Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kg. per bag of cement of approved make and manufacturer and curing etc.(Excluding Tiles). complete.As directed by Engineer in charge. (S. S. R. I. No. 31.06 & Page No. 264)
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.As directed by Engineer in charge. (S. S. R. I. No. 31.05 & Page No. 264)
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3 butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) (SSR 2019-20, Item no.31.13, Page no.266, Additional specification Bd.J.2 Page No.355)
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete.Spec. As directed by Engineer in charge. (S. S. R. I. No. 32.21 & Page No. 262) For Water Tanks
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of over all size 0.90mx2.40m with aluminium door frame of powder coated section 101.60x44.75mm, 3.18mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150mmx44.5mmx3.00mm thick top rails 47.62x44.45mmx3.00mm thick, vertical style 47.62x44.45mm,3.00mm thick and for shutter plain glass panes 5mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc., I.S.I. mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer incharge including all materials , labours, and equipment etc. complete Spec as directed by engineer in charge.
Providing and fixing Solid Core Flush Door Shutter In Single/Double Leaf 32 mm Thick Decorative Type Of Exterior Grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Spec. No. BD-T-34 Page No. 499.
Providing and fixing Fiber Glass Reinforced Polyster Door Shutter 30 mm Thick As Per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete. Spec. No. As directed by Engineer in charge. (S. S. R. I. No. 39.58 And Page No. 321 For Toilet Doors
Providing and Fixing of Mineral Fibre Board Acoustical Suspended Ceiling System with ultima (Bevelled Tegular) Edge Tiles of size 15mm Exposed GRID. The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k= 0.052-0.057w/mK, Colour White, Fire Performance UK Class 0/ Class1 (BS 476 pt-6&7) in module size of 600x600x20mm, suitable for Green Building application, with Recycled content of 32%. The tile shall be laid on precoated G.I. channel on XL 2 Clip having a web height of 32mm with 15mm wide T-section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200mm and 600mm Cross Tees with a web height of 32mm and a load carrying capacity of 7.7Kgs/M2 and minimum pull out strength of 100Kgs.. The T Sections have a Galvanizing of 90grams per M2 and need to be installed with Suspension system. The Tile and Grid system used together should carry a 10 year warranty. products approved as per GRIHA and BS 476 etc. complete. Spec as directed by engineer in charge. (I.N.38.45, P.N.309)
Providing and fixing Frame With / Without Ventilator Of Size As Specified With Country Cut Teak Wood For Doors And Windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 39.01 & Page No. 306)
Providing Antitermite Treatment To The Wooden Frames Of Doors / Windows of the existing building as per I.S. 6313 (Part-III) by drilling 6mm dia. holes at four corners on one side and four corners on other side at a downward angle of about 45 degree at the junction of wood work and masonary and injecting 150 ml. of chlorodane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee on bond paper. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 21.26 And Page No. 190)
Fire Door 45mm 1HR FRL (60/60) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. Providing of Tufwud make 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140? C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ('Non Combustible by Nature'). with prior approval of concerned Superitending Engineer. a) Door Frame: Supplying 'Tufwud' brand frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 kg/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 60 mm spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10mm x 4mm affixed in the slit of the Frame for fire and smoke sealing, etc. complete.
Fire Door 45mm 1HR FRL (60/60) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. Providing of Tufwud make 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140? C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ('Non Combustible by Nature'). with prior approval of concerned Superitending Engineer. b)Shutter : Providing of 65mm thick asbestos free composite - 3 criteria - fire, heat and smoke check Accoustic Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2x9mm Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x32 mm with 32mm thick infill of ceramic fiber (density 128Kgs/CMT), vermaculite mix faced with 6mm Fire retardant High Density ply, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of In tumescent paint of minimum 200 micron, and with 1 row of Brush- Type Astroflame? intumescent strip (imported) of size 10mmx4mm concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping.
Vision Panel 1 HR rated E Class clear high stress fire rated glass is pre fabricated strategically inside the shutter structure with 10 mm inside the shutter on all sides with Uglazing. An additional insulated powdercoated 'Z' channel of 16 swg MS sheet to be fixed for reinforcement of the joints. With clear fire resistant glass panes 11mm thick having minimum 120 minutes fire Description
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Spec as directed by engineer in charge.
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box. Spec as directed by engineer in charge. (S. S. R. I. No. 39.43 & Page No. 317)
Providing and fixing 900mm high S.S. 304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding, finishing, buffing to stainless steel pipe etc. complete (S. S. R. I. No. 40.07 & Page No. 339 (for first floor)
a) Ground Floor
b) Ground Floor
Providing and fixing jali fly proof for windows, ventilators etc. as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. For ground floor
Supplying and Erecting Pre Engineering Building (PEB ) Structure as per Detail design and drawing of Primery member such as columns, rafter, monitor roof, gable end columns, crane and secondery member such as roof bracing, columns bracings, purlins, wall girt, cleat clips, eves strut, hanger bracing, sag rod should be confirming to IS CODE - 800 & 875, 1893, AISC, MBMA. All steel supply should be in sound condition. All the fabrication work should be done as per IS-800. All structural member should be weld should be confirm IS-816, welding steel confirming to IS-2062,8500, used welding electrodes confirming to IS-814 and necessery size nut bolt including fabriction work of Canopy and valley gutter as per drawing, cleaning to remove dirt, grease, oil and loose mill, one coat of anticorrosive paint and two coats of synthetic enamle paint shall be confirming to IS-102,104. and all Provisions for elecrical lumineries and fitting fixing with all materials supply, transportation to place of work. Spec. No. As Directed By Engineer In Charge. (NON SSR)
Providing and fixing colour coated Zincalume (R) AZ150 (min150gms/sq.mt. total on each side) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45mm Base Metal Thickness (BMT) (0.5mm TCT), Hi-strength steel with min. 550MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLOR BOND (R) steel quality super durable polyester paint coat (within organic pigment). The paint shall have a total coating thickness of nominal 35um, comprising of nominal 25um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom.950-1050 mm effective cover width and nominal 25-30mm deep ribs with subtles quarefluting in the five panat nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25um Zinc-Tin alloy coated, Hexhead, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) Spec. No. Directed as per engineer incharge (S. S. R. I. No. 38.34 & Page No. 302)
Providing and fixing welded mesh of 11 gauge wires having mesh size 50 mm x 25 mm including M.S Angle frame of size 35 mm x 35 mm x5 mm in position with oil painting 3 coats etc. complete As directed by Engineer in charge. (I.No.39.79, P.No.333) for first floor
Providing and fabricating structural steel work for Spiral Staircase in rolled sections like channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted/ bolted/ welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. all complete as per architectural drawings and the directions of Engineer-in-charge. (including Landing). (Non SSR- Additional reference CPWD Analysisi of Rates for Delhi 2019 Vol-I, Item No 5.9.8)
Painting letters upto 20cm height complete brushes, coir brushers, dusting, cleaning, including cost of paint etc. complete. Spec. No. MORTH801
Providing and fixing during laying in R. C. C. Slab rectangular 2 mm thick M.S. sheet fan hook box of size 180x100 mm with required depth with holes or notches as required, bottom and top sides of 1.6 mm M.S. sheet fixed with 3.5 mm dia. round headed screws together with 12 mm dia. M.S. bar bent to shape with hooked ends for fan hook and painting to exposed surface Spec. No. As Directed By Engineer In Charge.
a) Ground Floor
b) First Floor
Pointing : Providing flush grooved pointing with cement mortar1:3 for stone masonry work including scaffolding and curing etc. complete.
Providing flush grooved pointing with cement mortar1:3 for stone masonry work including scaffolding and curing etc. complete.
Providing & Fixing Bituminous pad 25 mm thick for expansion joint in compound wall
Providing & Arrangemnt of Mid Back, ECOCTS Mechanism, Fixed Armrest, Gas lift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery Spec. No. As Directed By Engineer In Charge. Weighbridge (S. S. R. I. No.51.43 And Page No. 466)
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 22.19.1 3 mm thick ( CPWD D.S.R. 2015-16 w.e.f July-2016 I. No. 22.19 & Page No. 385 ) For Terrace
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge Rain Water Harvesting (S. S. R. I. No. 48.46 & Page No. 405)
RWH - Shallow Percolation Pit providing, constructing 2.0m deep shallow depth percolation pit comprising of 1.0m dia pre-cast RCC rings, 300mm thick side filling around outside of RCC rings (annular space) with 40mm size boulders including filling of percolation pit up to 0.5m depth (from bottom up) with 25-75mm clean washed gravels followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs etc. including arrangement for inlet & outlet pipe, excavation & backfilling as shown in the drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge - Rain Water Harvesting (S. S. R. I. No. 48.46 & Page No. 405)
Boring/drilling bore well of 300mm dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machinery required for the job, all complete as per direction of Engineer in charge, upto 90m depth below ground level.-Rain Water Harvesting
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well-casing pipe of 150mm dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per the
Supplying and erecting submersible pumpset of 2.25 KW/3HP with 415 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable for 85 to 170 LPM discharge at 67 to 27 m head & (max. efficiency at 49 m head & 130 lpm) discharge & delivery pipe of Size-50 mm diameter with a necessary H type clamps as per specification No. WP-SMP
Supplying and erecting submersible pumpset of 3.75 KW/5 HP with 415 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable for 85 to 170 LPM discharge at 110 to 46 m head & (max. efficiency at 83 m head & 130 lpm) discharge & delivery pipe of Size-65 mm diameter with a necessary H type clamps as per specification no. WP-SMP
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.c. Submersible/centrifugal pump set upto 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powdercoated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete.
Aluminium Section
Providing and fixing aluminium work for Entrance Gate with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately)
Façade Items
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with 415 SUB HEAD : 8 - CLADDING WORK aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.
Sanitary Fittings (for ground floor)
Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete. Spec. No. As Directed By Engineer In Charge (S. S. R. I. No. 42.34 And Page No. 355)
Providing and fixing 1st class white glazed earthenware orissa type W. C. pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. Spec. No. As directed by Engineer in Charge. (S. S. R. I. No. 42.33 And Page No. 355)
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420x 590x 195 mm size with pillar cock, C.P. Angular stop cock, long thread of approved make continent alincluding SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black/Colour Granite of 180 mm thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. (S. S. R. I. No. 48.35 And Page No. 402)
Providing and fixing white glazed earthenware lipped flat back / corner type urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. Spec. No. Bd.V. 26 Page No. 564.(S. S. R. I. No. 41.60 And Page No. 347)
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec. No. As directed by Engineer in charge(S. S. R. I. No.42.83 And Page No. 362)
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.82 And Page No. 361)
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.79 And Page No. 361)
Providing and fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.32 And Page No. 355)
Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.80 And Page No. 361)
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.31 And Page No. 355)
Providing and fixing 450 mm x 550 mm size superior type belgium mirror with 16mm dia. nickel plated towel rod etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.20 And Page No. 353)
Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete.
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.51 And Page No. 358)
Providing and fixing 110 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.52 And Page No. 358)
Providing and fixing on walls / ceiling / floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.55 And Page No.358)
Providing and fixing on walls / ceiling / floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.56 And Page No. 358)
Providing and fixing on walls / ceiling / floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.57 And Page No. 359)
Providing and fixing on walls / ceiling / floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.59 And Page No. 359)
Providing and fixing on walls / ceiling / floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.60 And Page No. 359)
Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec. No. Bd.V.43 Page No.574. (S. S. R. I. No. 42.17 & Page No. 353 )
Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cmx 90 cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover medium duty 140 kg. etc complete
Providing and constructing Brick Masonry inspection trap Chamber 60cm x 60cmx 120 cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover medium duty 140 kg. etc complete
Providing and constructing Brick Masonry inspection trap Chamber100cm x 100cmx 120 cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover medium duty 140 kg. etc complete
Providing and fixing Shower Head with shower arm of approved make shower tube hand shower with divertor of spout including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge.
Providing and fixing Hand shower (health faucet) with 8mm dia. 1m long flexible tube having wall hook with approved make including necessary sockets/ unionnutetc. Complete as directed by Engineer in charge.
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. Bd.V.38 Page No.572.
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. Spec. No. Bd.V.46 Page No.576.
Supplying & Laying ( Including Excavation of Suitable width 7 Depth upto 90 cm ) 120 mm outsidr diameter Double wall corrugated pipes of HDPE for enclosing cable below ground to required depth complete. HDPE Pipe 100 mm pipe
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge.
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge.
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compoundand laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 31.04 & Page No. 263
Providing waterproof plaster in W.C. and bath 12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kg. per bag of cement of approved make and manufacturer and curing etc.(Excluding Tiles). complete.As directed by Engineer in charge. (S. S. R. I. No. 31.06 & Page No. 264) for first floor
Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete.As directed by Engineer in charge. (S. S. R. I. No. 31.05 & Page No. 264) for first floor
Providing and laying jointless Polydee-LM, a highly flexibleelastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, after application of TP-42 Primer on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee-LM @ 700 gms/sqm and applying 2nd coat of Polydee-LM @ 700 gms/sqm and finishing the same with sprinkling the AG-10 granules on the wet coating. (After finishing covering the treatment with 25mm cement plaster for protection with fibrillated 6mm Plyplast fibre @ 125 gms/sqm to be paid in separate item.) covering 7 years guarantee on Court Fee Stamp Paper of Rs. 100/- etc. complete for first floor
Providing and fixing Solid Core Flush Door Shutter In Single/Double Leaf 32 mm Thick Decorative Type Of Exterior Grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. Spec. No. BD-T-34 Page No. 499. for first floor
Providing and fixing Fiber Glass Reinforced Polyster Door Shutter 30 mm Thick As Per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc complete. Spec. No. As directed by Engineer in charge. (S. S. R. I. No. 39.58 And Page No. 321 For Toilet Doors (for first floor)
Providing and fixing Frame With / Without Ventilator Of Size As Specified With Country Cut Teak Wood For Doors And Windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 39.01 & Page No. 306) for first floor
Providing Antitermite Treatment To The Wooden Frames Of Doors / Windows of the existing building as per I.S. 6313 (Part-III) by drilling 6mm dia. holes at four corners on one side and four corners on other side at a downward angle of about 45 degree at the junction of wood work and masonary and injecting 150 ml. of chlorodane 5% W.C. and sealing by filling putty etc. complete covering 2 years guarantee on bond paper. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 21.26 And Page No. 190) for first floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Spec as directed by engineer in charge. for first floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating with box. Spec as directed by engineer in charge. (S. S. R. I. No. 39.43 & Page No. 317) for first floor
Providing and fixing jali fly proof for windows, ventilators etc. as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. for first floor
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. Spec. No. Bd.C.2 Page No. 275 (S. S. R. I. No. 23.01 & Page No. 214) For Service Ladder, Main Entrance Door And Canopy for first floor
Providing and fixing colour coated Zincalume (R) AZ150 (min150gms/sq.mt. total on each side) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45mm Base Metal Thickness (BMT) (0.5mm TCT), Hi-strength steel with min. 550MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLOR BOND (R) steel quality super durable polyester paint coat (within organic pigment). The paint shall have a total coating thickness of nominal 35um, comprising of nominal 25um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom.950-1050 mm effective cover width and nominal 25-30mm deep ribs with subtles quarefluting in the five panat nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25um Zinc-Tin alloy coated, Hexhead, self-drilling screw etc. complete. (weight of profile 4.52 kg/sqm) Spec. No. Directed as per engineer incharge (S. S. R. I. No. 38.34 & Page No. 302) for first floor
Providing and fixing 4 to 8mm thick radient thermal insulation sheet fixing with with self drilling screws with necessery tongue and groove jointer, ridge, hip or valley or eaves board & fecia and all trims, gutters and necessery provision to close & protect shet egder, with necessery cutting of windows / dors and opning as per opning schedule, including fixing with approved self tapping screws, nut bolt and EPDM washers and scaffolding etc. Complete. Spec. No. As Directed By Engineer In Charge. ( Non SSR for first floor
Providing and fixing Turbo Ventilators 24" with necessery provision to close & protect sheet egder, with necessery cutting of windows / dors and opning as per opning schedule, including fixing with approved self tapping screws, nut bolt and EPDM washers and scaffolding etc. Complete. Spec. No. As Directed By Engineer In Charge. ( Material No. 42 Page No. 516 ) for first floor
Façade Items
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with 415. for first floor
Sanitary Fittings. ( for first floor )
Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete. Spec. No. As Directed By Engineer In Charge (S. S. R. I. No. 42.34 And Page No. 355)
Providing and fixing 1st class white glazed earthenware orissa type W. C. pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. Spec. No. As directed by Engineer in Charge. (S. S. R. I. No. 42.33 And Page No. 355)
Providing and fixing coloured glazed earthenware wash hand basin of 63 cm x 45 cm Size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. Spec. No. Bd.V.30 Page No.565(S. S. R. I. No. 41.74 And Page No. 359)
Providing and fixing white glazed earthenware lipped flat back / corner type urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. Spec. No. Bd.V. 26 Page No. 564.(S. S. R. I. No. 41.60 And Page No. 347)
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec. No. As directed by Engineer in charge(S. S. R. I. No.42.83 And Page No. 362)
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.82 And Page No. 361)
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.79 And Page No. 361)
Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.80 And Page No. 361)
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.31 And Page No. 355)
Providing and fixing 450 mm x 550 mm size superior type belgium mirror with 16mm dia. nickel plated towel rod etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.20 And Page No. 353)
Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete.(S. S. R. I. No. 42.67 And Page No. 360)
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.51 And Page No. 358)
Providing and fixing 110 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.52 And Page No. 358)
Providing and fixing P.V.C. Rain water pipes of 160 mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming To I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment) Spec. No. As Directed By Engineer In Charge.(S. S. R. I. No. 42.85 And Page No. 362)
Providing and fixing on walls / ceiling / floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.55 And Page No.358)
Providing and fixing on walls / ceiling / floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.56 And Page No. 358)
Providing and fixing on walls / ceiling / floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.57 And Page No. 359)
Providing and fixing on walls / ceiling / floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.59 And Page No. 359)
Providing and fixing on walls / ceiling / floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(S. S. R. I. No. 42.60 And Page No. 359)
Providing and fixing Shower Head with shower arm of approved make shower tube hand shower with divertor of spout including all necessary pipe fittings and connections etc. complete as directed by Engineer in charge. (S. S. R. I. No. 48.33 And Page No. 403)
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.36 And Page No. 355)
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (S. S. R. I. No. 42.37 And Page No. 355)
Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 kg) (SSR 2019-20, Item no.42.68, Page no.360, Additional specification :As directed by Engineer in charge.) UGWT
Supplying and erecting Centrifugal water pump (Monoblock), 230V, Single phase 50 cycles A.C. supply of 1.5 KW/2 HP with discharge 7.16/4.16 Litres per second (LPS) for head of 12/21 m & 50 mm suction/ 50 mm delivery pipe on provided C.C.nfoundation as per specification. UGWT
Supplying and erecting Centrifugal water pump (Monoblock), 230V, Single phase 50 cycles A.C. supply of 1.5 KW/2 HP with discharge 7.16/4.16 Litres per second (LPS) for head of 12/21 m & 50 mm suction/ 50 mm delivery pipe on provided C.C.nfoundation as per specification. UGWT
Supplying and erecting Centrifugal water pump (Monoblock), 415V, three phase 50 cycles A.C. supply of 2.25KW/ 3 HP with discharge 4.9/9.2 Litres per second (LPS) for head of 10/26 m and 65 mm suction/ 50 mm delivery pipe on provided C.C. foundation as per specification UGWT
Supplying and erecting D. O. L. Starter suitable for 250V. Single phase, 50 cycles with overload element with necessary materials and connected to supply upto 3 H.P - UGWT
Supplying and erecting D.O.L. Starter 400V. 3 phase, 50 cycles with no volt coil and overload element with necessary materials and connected to supply upto 7.5 H.P. - UGWT
Supplying and erecting pump protection relay comprising current sensing phase failure and UV+OV relay with dry run and overload protection suitable for 3 phase pumps. UGWT
Supplying & erecting Water lavel controller 230/ 415V AC., Four way for under ground & Over head tank operation. UGWT
Supplying & erecting Water level controller 230/415 V AC., Two way for under ground tank operation only. UGWT
Supplying & erecting PVC coated 5 mm dia Brass Sensor/ electrode duly wired with nut & bolts complete UGWT
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.c. Submersible/centrifugal pump set upto 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powdercoated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc. UGWT
Supplying & erecting Float sensor switch for water level controller working on 250V & rated current 8A, with 2 mtr. wire & High quality of wire & plastic body. UGWT
FURNITURE WORK
Visitor's Chair Description -Supply,installation and placing Dimensions: H 43.5 x W 19 x D 21 with Primary Material: four lages with round s.s. finished tube form with 20 mm dia/18mm dia as support for seat Leather & Stainless Steel ,It has cushioned seat and back,Light weight for moving to one place to another. Brand: wipro/equvalant
High Back Chair (New) Description - supply,installation and placing of High back chair Dimensions: H 43.5 x W 19 x D 21 with Seating Height - Min 17 & Max 21 Primary Material: Fabric Material, Net & Metal , Color: Black Net, Seat Upholstery Material: Net Fabric , Back Upholstery Material: Fabric Net, Base Material: plastic, Arm Material: Plastic,Wheel Material: Nylon, Upholstery Color: Black Net with Seat Lock also back is made up of injection moulded glass filled nylon and upholstered net fabric with high penacity yarn. Brand: Godraj/equvalant
TB1 - Plant Incharge Table Description -Supply,installation and placing of staff table Dimensions: L 3100mm x W 750 mm x H 750 mm with Steel-frame, apron and heavy-guage tubular steel legs & Chemsurf top: 1-1/8" thick and consists of a medium-density fiberboard core surfaced with an acid- and chemical-resistant Chemsurf high-pressure laminate surface. Edges have a urethane-based Sure Edge finish. Brand: Featherlite/equvalant
TB1 - Staff Table Description -Supply,installation and placing of staff table Dimensions: L 7500mm x W 600 mm x H 750 mm with Steel-frame, apron and heavy-guage tubular steel legs & Chemsurf top: 1-1/8" thick and consists of a medium-density fiberboard core surfaced with an acid- and chemical-resistant Chemsurf high-pressure laminate surface. Edges have a urethane-based Sure Edge finish. Brand: Featherlite/equvalant
TB1 -Admin Table Description -Supply,installation and placing of staff table Dimensions: L 2800mm x W 750 mm x H 750 mm with Steel-frame, apron and heavy-guage tubular steel legs & Chemsurf top: 1-1/8" thick and consists of a medium-density fiberboard core surfaced with an acid- and chemical-resistant Chemsurf high-pressure laminate surface. Edges have a urethane-based Sure Edge finish. Brand: Featherlite/equvalant
Single Bed Description - supply,installation and placing of bed Dimensions: 3'0" x 6'6" x 1'6" Primary Material: Mild Steel Made up of M.S.pipe of 1.2 mm thk. Colour: Epoxy powder coating with thk of 50 microns.Black Glossy Finish. Material:18 Gu Metal Frame,Coating: 7 Tank Coating Method,Durable,All joints are fully welded Brand: Furniture kraft /equvalant
Wardrobe (New) Description -supply,installation and placing of Wardrobe Dimensions: W 6'0" X D 2'0" X H 6'9" with Godrej Interio Storwel TH Metal Almirah Color: Graphite Grey, Material: welded constrction ,0.7 thk CRCA for shelf,0.8 mm thk CRCA for back and locker shelf ,0.8 mm thk HSCR for doors,0.9mm thk CRCA for all other components Metal, 2 separate drawers for storing smaller items , with key locker three way locking arrangement with shooting bolt.,Fixed half locker with secret compartment Mirror option available shelfs as hight wise adjustable. Brand: JVM Industries/Godrej Make/equvalant
Side table Description -Supply,installation and placing Dimension- 2'0" X 1'6" X 2'0" MS Sidetable with ventilating louvers on press lock door. Fixed legs on four 5cm stumps. Die Pressed, Seamless, Stainless Steel top with seamless raised edges on three sides. Pretreated and electrostatic powder coated. Brand : Azad Interprise /equvalant
Steel Rack (New) Description -Supply,installation and placing of steel racks Dimension- 3'0"x1'6"x9'9" Steel Rack with 7 shelves and Slotted Angle Rack which has 18 inch fixing rail with frame gauge :14 Machine multiband moulded to with stand load of 75 to 100 kg. per shelves. slotted angles size : 40mmx40mmx2mm thk. sheleves : 900 mmx 380 mmx1.2 mm thk. Brand : IB basics /equvalant
New notice boards (Soft Boards) (New) Description - Supplying notice board of size 4'0"x 3'0" . The board have high density softboard core with high tear resistant velvet cloth & satin-finish Alloy Aluminium Frame with ABS Corners. The cost includes the board with 4 wall mounting clip set.
Wall Paper (New) Description - Providing wallpaper of approved design and applying wallpaper on the wall. The entire cost to include wallpaper cost and labour charges.The entire job will be done completely with all specifications as directed by engineering incharge, keeping the area clean after work.
Semicircular Reception Table- 7'0"x2'0"x2'6" (New) Description - Providing and laying and fixing semicircular shaped table of size 7'0" outer diameter and 2'0" wide.The table shall consist of 19mm thk. marine ply of approved make & 1mm thick laminate of approved make on table vertical and 12mm thick glass table top.Also,providing and fixing of 2 drawers and 1 keyboard drawer using 3 channels for fixing. Also providing and fixing of 2 handles,and 2 locks as per requiremnt.Providing polish for lipping of exposed edges of ply and for internal surfaces of the table.The cost to include all fixtures, Labour etc. complete with all specifications as per detailed drawing as directed by engineering incharge.The work shall be done neat and complete with all necessary fittings & fixture.
Cupboard (New) -Exporter Cabin Description - Providing and fixing of 18mm thk marine ply of approved make for double leaf shutters of the cupboard of size 6'0"x1'6"x7'0" with 6 new heavy duty W hinges 4" for cupboard. Also fixing of new 1mm thk. laminate of approved make on external face of the shutters and applying polish for internal faces. Also 2 shelves will be fixed inside the cupboard using shelf buttons .Providing and fixing 2 nos. of 4" handles for shutters and 2 magnets each for two shutters with 1 towerbolt 8" . Providing and fixing of 2 nos. 4" handle for each shutter. Applying polish for the edges of cupboard and shelves.The cost to include all fixtures,material, labour etc.The entire job will be done completely with all specifications as directed by engineering incharge, keeping the area clean after work.
Cupboard (New) -Plant Incharge Description - Providing and fixing of 18mm thk marine ply of approved make for double leaf shutters of the cupboard of size 8'0"x1'6"x7'0" with 6 new heavy duty W hinges 4" for cupboard. Also fixing of new 1mm thk. laminate of approved make on external face of the shutters and applying polish for internal faces. Also 2 shelves will be fixed inside the cupboard using shelf buttons .Providing and fixing 2 nos. of 4" handles for shutters and 2 magnets each for two shutters with 1 towerbolt 8" . Providing and fixing of 2 nos. 4" handle for each shutter. Applying polish for the edges of cupboard and shelves.The cost to include all fixtures,material, labour etc.The entire job will be done completely with all specifications as directed by engineering incharge, keeping the area clean after work.
Cupboard (New) -BAck Office Description - Providing and fixing of 18mm thk marine ply of approved make for double leaf shutters of the cupboard of size 8'0"x1'6"x7'0" with 6 new heavy duty W hinges 4" for cupboard. Also fixing of new 1mm thk. laminate of approved make on external face of the shutters and applying polish for internal faces. Also 2 shelves will be fixed inside the cupboard using shelf buttons .Providing and fixing 2 nos. of 4" handles for shutters and 2 magnets each for two shutters with 1 towerbolt 8" . Providing and fixing of 2 nos. 4" handle for each shutter. Applying polish for the edges of cupboard and shelves.The cost to include all fixtures,material, labour etc.The entire job will be done completely with all specifications as directed by engineering incharge, keeping the area clean after work.
Conference Table Description - Repairing of U shaped table 2'3" wide table top on three sides and table centre size 17'x6'6"x2'6" and two sides size 12'0" x 2'9"x 2'6" . Providing veneer polish for all the surfaces and veneer polish on lipping. The cost to include all fixtures, material,labour etc. complete with all specifications as per detailed drawing as directed by engineering incharge. The entire job will be done completely, keeping the area clean after work.
Side Storage Cabinet - Description - Providing and fixing of 12mm thk marine ply of approved make for the back board of the side storage cabinet. Providing and fixing of 1mm thk. new laminate of approved make of specified color for the side storage of size 8'0"x1'6"x4'0" on the old laminates using Araldite as a medium for fixing the laminates. Providing and fixing of 12nos. of heavy duty shutter hinges 4" , and also providing and fixing of 3 shutter locks, 6 handles 4" and 3 towerbolt 3". Also providing and applying wooden polish for lipping . Providing and applying wooden polish for internal surfaces of the storage. The cost to include all fixtures, material, labour etc. complete with all specifications as per detailed drawing as directed by engineering incharge. The entire job will be done completely , keeping the area clean after work.
Providing and Placing of Orthomatic Delux Matress with thickness 125mm. 10 years replacement warranty, both side usable with 78 x 36 inches.
Providing and Placing of Pillow L:425mm W:675mm
Providing and Placing of Single Bed sheet with pillow cover
Providing and Placing of SYNTHETIC LEATHER 1 SEATER SOFA with 1200mm (W) x 850mm (D) x 890mm (H), THREAD - Same colour Nylon/ Polyester, PITCH - 22 stiches per inch, normal setting, LEATHER/PVC/FABRIC: - 800 GLM PVC top coat 200, middle coat 500, fabric polyester knitted,Sautex fabric. FRAME MATERIAL- PINE WOOD, MOISTURE CONTENT : - less than 8%. SEAT FOAM: (DENSITY, TYPE) - block foam in multiple of 24 mm. thickness 28- 30 kg./m3. BACK FOAM: (DENSITY, TYPE) - 26-28 d. ARMREST FOAM: (DENSITY, TYPE) - 28-30d. BELT/ WEBBING MATERIAL:- 48mm wide for Backs and 72mm wide for seat, inter woven for better support. LEG MATERIAL: - Mild Steel, Chrome plated 125 mm. High. BONDING SOLUTION: - Sprayable rubber adhesive.
Providing and Placing of SYNTHETIC LEATHER 3 SEATER SOFA with 1820mm (W) x 850mm (D) x 890mm (H), THREAD - Same colour Nylon/ Polyester, PITCH - 22 stiches per inch, normal setting, LEATHER/PVC/FABRIC: - 800 GLM PVC top coat 200, middle coat 500, fabric polyester knitted,Sautex fabric. FRAME MATERIAL- PINE WOOD, MOISTURE CONTENT : - less than 8%. SEAT FOAM: (DENSITY, TYPE) - block foam in multiple of 24 mm.thickness 28- 30 kg./m3. BACK FOAM: (DENSITY, TYPE) - 26-28 d. ARMREST FOAM: (DENSITY, TYPE) - 28-30d. BELT/ WEBBING MATERIAL:- 48mm wide for Backs and 72mm wide for seat, inter woven for better support. LEG MATERIAL: - Mild Steel, Chrome plated 125 mm. High. BONDING SOLUTION: - Sprayable rubber adhesive.
Providing and placing of coffee table with dimension 1100mm (w) x 600mm (d) x 460mm (h). Table legs meterials & size : metal round tube. Table top materials & size : (density / type): oval glass. Color - partial black top with full black bottom shelf. Finishing - black glass top and chrome frame and legs.
Providing & Placing Of Mid Back Chair- Seat / back assembly - the seat is made up of 1.2 +/- 0.1 cm. Thick hot pressed plywood, measured as per qa method described in ocp-qlta - pl40-18. The back is made up of injection moulded glass filled nylon and upholstered net fabric with high penacity yarn. Seat size- large seat depth- (47.0 cm.(W) x 51.5 cm (D). SEAT SIZE- DEPTH (47.0 cm.(W) x 49.5 cm(D). BACK SIZE 45.O (cm) (W) x 65.3 (cm) (H). High resistance polyurethene foam the hr polyurethene foam is moulded with density = 55+/- 2kg/ m3, and hardness 16 +/- 2 kgf, as per is: 7888 for 25% compression. Armrest adjustable- with updown adjustment 8.5 +/- 0.5 cm. Which is provided in armrest structure. Armrest top as an itegrated layer of thermoplastic elastomer, armrest is made of plastic injection moulded nylon with textured top, lumbar support assly. Consists of polypropylene pad with moulded polyurethene foam and covered with polyster fabric. Height of lumbar pad can be adjusted through two projecting knobs provided under rearer side of the pad. Lumbar pad has an adjustment of 8.0+/- 0.5 cm. In height. Front pivote syncro. Mechanism. Adjustable tilting mechanism is designed eith the following features. • 360° revolving type. Single pivote control. Front pivote for tilt with feet resting on ground ensuring more comfort. Tilt tension adjustment. 4 position liking with anti shock feature, seat back tilt ratio 1:2, pneumatic height adjustment has an adjustment stroke of 10.0 +/- 0.3 cm. Pedestal assly. Is injection moulded in black 30% glass filled nylon, and fitted with 5 nos. Twin wheel castors. The pedestal pitch- center dia. Is 66.1 +/- 0.5 cm. (76.1 +/- 1.1 cm. With castors. Twin wheel castors are injection moulded in black nylon.
Providing and placing of Storwel Plain shall have an overall size of 916mm(W)x486mm(D)x1980mm(H) with welded construction. It should have the shelf thickness of 0.7 mm, Back thickness of 0.8mm, Door thickness of 0.8mm (high yield strength) and all other components shall have a thickness of 0.9mm. These components shall be made of CRCA ‘D’ grade high yield strength as per IS:513. The Storwel Plain should have a Mazak handle and Three way locking mechanism with Shooting Bolts. It should have a height wise adjustable shelf mounting which shall have a Uniformly Distributed Load Capacity of max 40 Kg. It should also have a M10 Screw type Leveller with Hex plastic base. The finishing shall include Epoxy powder coated to the thickness of 50 microns (+/- 10). Plenty of colour options and shelving options shall be available.
Providing and fixing locker size of 0.91 L x 0.51 W x 2.00 H with 6/8/9/12/15 compartments made from CRCA steel. All steel components are to be anti-corrosive treatment. All locker doors to be ventilating louvers for air circulation. Locking system with Pad Lock and key etc. complete. As directed by Project Manager / Consultant
STONE VENEER CLADDING
Key Holder (New) Description - 1 KeyHolder, 2 hole plugs, 2 Screws, 1 Instruction Manual Key resting pad to prevent scratches on board. 10 Knobs for hanging all types of keys Made of premium high-grade prelim wood with Natural Wenge Wood Grain Finish. The entire job will be done completely with all specifications as directed by engineering incharge, keeping the area clean after work.
Signages Description - Brand : Signatare Size :2'0''x0'4'' Shape : Rectangle Body material : Stainless steel fine quality techically tested longer life .Providing and fixing of signages with description of department name/room name on it as per requirement. The entire job will be done completely with all specifications as directed by engineering incharge, keeping the area clean after work.
Landscape Work
excavation for foundation in soft strata which does not requied blasting up to 1.5 Mtr. Depth including removing the excavated material up to distance of Mtrs (i.e.about 164')beyond the building area and lift.(PWD-CSR,2016-2017, page no-12, sr no-1)item code lia/1BDA1.
Filling fresh garden soil / silt & manure in excavated area including lead upto a distance of 50 Mtrs.(PWD-CSR,2016-2017,Page no.-16, Sr. No,.-1)&item code10/1BDA11
Mixing garden soil /silt & manure thoroughly well, watering previous night . Planting required plant species , lawn grass as directed etc. complete (1/10 of semiskilled labour)
Supplying and transporting & spreading of good quality Golden sand including the cost of spreading the sand,loading unloading etc complete. Including all taxes without GST As directed by engineer Incharge.
Providing and laying rounded white pabbes from approved quality pebbles being of minimum size 25mm dia. Being free of dust, dirt and other impurities including all other taxes, octri and transportation,etc. complete as specified by Engineer in charge
Providing and Fixing of POP UP SPRAY 4" size (SPRINKLER) of rigid plastic on site. It is manufactured from special grade vergin polymers. Parts resistent to corrosion in treated recycled water containing chlorine and other chemicals. Strong stainless stell spring provides reliable stem retraction and withstands corrosion.Rate is inclusive of all other taxes, transportation, loading, unloading, laying, all reuired labour etc. complete as directed by engineer in charge 1) working pressure:1-4 kg/sqm. 2)Discharge flow:0.15-0.85 cum/Hr. 3)Radius:3 to 5.5 m 4)Inlet size: 1/2" female threaded inlet 5)Rugged ribbing case for maximum strength and durability. 6)part and full circle in one head
Providing and Fixing of POP UP SPRINKLER 9.5" of rigid plastic on site. The Pop sprinkler powerful throw permits maximum spacing and offers superior close in watering and uniform water distribution. Low pressure loss and efficient, staight through flow design conserve energy and are ideal for dirty water application. Non strippable gear drive function. Rate is inclusive of all type of taxes, transportation, loading, unloading, laying, all reuired labour etc.complete as directed by engineer in charge 1) working pressure:2-4 kg/sqm. 2)Discharge flow:0.35-1.86 cum/Hr. 3)Radius:6 to 13 m 4)Inlet size: 1/2" female threaded inlet 5)Rugged ribbing case for maximum strength and durability. 6)part and full circle in one head
Providing and fixing Dripper of 4 liter per hour discharge 75 cm center to center on the LLDPE lateral, Jain make Rate is excluding GST transportation, loading, unloading, laying, all reuired labour and all other taxes etc. as directed by the Engineer In charge.
Providing and Fixing of SAND FILTER (GRAVEL FILTER) with on site. It shoud be vertical with mushroom fitted on plate seperating sand bed and clean water chamber with a sand bed depth of about 500mm. It shoud be installed with vaccum breakers to prevent vaccum inside the filter. The shell should be provided with a drain plig at bottom to drain out fine sediments and aside hand hole to facilate easy removal of sand from the shell whenever the sand needs replacement. The filter housings should be protected by an extra durable epoxy paint from outside and black bituminous paint from onside. Transportation, loading, unloading, laying, all reuired labour etc.and all other taxes, As directed by Engineer incharge.
Providing & fixing on site gun metal gate valve of approved make of 63mm diameter,having wall thickness of 7mm. Pressure rating of 10 bar. The item includes all labour, tools, equipment, transportation, loading & unloading complete with proper fixtures and fasteners, necessary for installation as per drawing and specification attached and as directed by the Engineer In charge of the work.
Providing earth work in embankment with approved materials obtained from departmental land or other sources upto lead of 50m. including all lifts, laying in layers of 20cm. to 30cm.thickness breaking clods, dressing to the required lines, curves,grades & section, watering and compaction with vibratory roller with VSat attachment to achieve not less than 97 % of standard proctor density etc. complete
GARDEN SOIL: Supplying on the site garden soil well sieved 90% to pass through I.S. sieve of 10mm size free from stones rubbish like dried grass roots and other such materials. The soil should be fresh from quarry. The colour of the soil generally be red. The soil will be measured by measuring box. (Farma) (Item includes Royalty charges, Transporting, loading unloading etc.) lead charges for 30 k.m. Is considered
FARM YARD MANURE: Supplying on site well decayed, well dried, well powdered, without clods and free from stones, dried grass and other rubbish material. The colour of the manure generally be black. The manure will be measured by measuring box. (Farma) (Item includes Transporting, loading, unloading etc.) lead charges for 30 k.m. Is considered
Rose plant: - Excavating pit with size 0.3mx0.3mx0.3m . Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil & manure in excavated area in 3:1 proportion to a height of 30 cm. Mixing garden soil & manure thoroughly, well, leveling, watering on previous night. Planting 40 to 50 cms height healthy plant of required rose variety and maintaining till well well established by watering, weeding, stirring, prunning replacing of casualties etc, complete.
Mogra plant: - Excavating pit with size 0.3mx0.3mx0.3m . Removing & conveying unwanted stuff to a required distance as directed. Filling the pit the approved excavated material upto a height of 0.15 m and remaining height of 0.15 mt with fresh garden soil & manure in excavated area in 3:1 proportion. Mixing garden soil & manure thoroughly, well, leveling, watering on previous night. Planting one or two year old healthy plant as per specifications. Maintaining till well well established by watering, weeding, stirring, prunning replacing of casualties etc, complete.
Providing and planting Rooted plants in microbag/polybag for edge/Border plant including excavating the ground to a required depth , removing &conveying unwanted stuff to a required distance as directed by engineer incharge.
Providing and planting rooted plants for hedge in polybag plant including excavating the ground to a required depth, removing &conveying unwanted stuff to a required distance as directed engineer incharge.
Providing and planting Lawn grass Cynadon/Paspallum/American blue including grass Excavating the ground to a required depth, removing &conveying unwanted stuff to a required distance as directed by engineer incharge.
Providing and planting ready to fix lawn turf in slabs or rolls grass including excavating the ground to a required depth , removing & conveying unwanted stuff to a required distance as directed by engineer incharge.
saplings of flowering /shady trees, gulmohar, raintree, peltophorum etc. height minimum to 1mtr.
saplings of flowering /shady trees, gulmohar, raintree, peltophorum etc. height minimum to 2mtr.
sapling of small &medium ornamental flowering plants, thuja.cupresus,palms, ornamental ficus ,mussanda,etc.0.5 mtr.
Providing and planting Well Developed Common Ornamental Shrubs for Shrubbery, 05 Mtr. Height as directed engineer incharge.
ground cover e.g. lantana,syngonium,wedelia, ipomoea,poths,pilea,chlophytum,common ferns etc.
Preparing Lawn (30 cms. Depth) Excavating the ground to a required depth of 30 cms, removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil/silt and manure in excavated area in 3:1 proportion to a height of 30 cms. Mixing garden soil and manure thoroughly, well, levelling, watering on previous night. Planting required variety of lawn grass as directed and maintaining till well established by watering, weeding, clipping, rolling, etc. Complete.
Preparing Instant Lawn: - Excavating the ground to a required depth of 20 cm. Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil & manure in excavated area in 3:1 proportion to a height of 20 cm. Mixing garden soil & manure thoroughly, well, leveling, wth required slope, light watering on previous night, rolling, on surface, fixing readymade lawn truf, rolls or slabs of required variety of lawn grass as directed. Ramming on it for proper fixing and maintaining till well established by watering, weeding, clipping rolling, etc complete. DSR
Preparing Edging or Border: Excavating the ground to a required depth of 20 cms., in the required area, removing and conveying unwanted stuff, rubbish to the required distance as directed. Filling the excavated part with fresh soil and manure in 3:1 proportion to a required height of 20 cms. Mixing, levelling, watering the same. Planting rooted edging/border plants at distance of 20 cms. Apart by watering, weeding, stirring of soil replacing casualties, pruning if necessary etc. Complete.
Planting clipped Hedge: Excavating the ground to a required depth of 30 cms, removing and conveying unwanted stuff to a required distance as directed. Filling fresh garden soil and manure in excavated area in 3:1 proportion to a height of 30 cms. Mixing garden soil and manure thoroughly well, levelling, watering previous night. Planting hedge plants of required species in two rows. Distance between two rows & between two plants will be 25 cms. Maintaining till well established by watering, weeding, stirring the soil and clipping if necessary etc. Complete.
Preparing flower bed: Excavating the ground to the required depth of 30 cms, Removing and conveying unwanted stuff to a required distance as directed, Filling fresh garden soil and manure in excavated area in 3:1 proportion to a required height of 30 cms Mixing garden soil and manure thoroughly well, levelling, watering on previous night. Planting seedlings of required annuals 25 cms. Apart Maintaining till well established by watering, weeding, stirring replacing of casualties etc. Complete.
Preparing canna bed: - Excavating the ground to a required depth of 30 cm. Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil & manure in excavated area in 2:1 proportion to a height of 30 cm. Mixing garden soil & manure thoroughly, well, leveling, watering on previous night. Planting well devoloped canna rhyzomes 40 cms apart. Maintaining till well well established by watering, weeding, stirring replacing of casualties etc, complete.
Preparing shrubbery: Excavating the ground to required depth of 30 cms, removing and conveying unwanted stuff to a required distance as directed. Filling fresh garden soil and Manure in excavated area in 3:1 proportion to a height of 30 cms. Mixing garden soil and manure thoroughly well, levelling, watering on previous night. Planting well developed shrubs plants, 0.50 mtr. Height, 0.45 Mtrs. Apart as directed and maintaining till well established by watering, weeding, stirring, replacing casualties etc. Complete.
Rose plant: - Excavating pit with size 0.3mx0.3mx0.3m . Removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil & manure in excavated area in 3:1 proportion to a height of 30 cm. Mixing garden soil & manure thoroughly, well, leveling, watering on previous night. Planting 40 to 50 cms height healthy plant of required rose variety and maintaining till well well established by watering, weeding, stirring, prunning replacing of casualties etc, complete.
Planting large flowering/shady trees: (Minimum Height to 1 Mtr.) - Digging pit with size 0.9m x 0.9m x Height to 1 Mtr.) - Digging pit with size 0.9m x 0.9m x 0.9m removing and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material upto a height of 0.30 m. and remaining height of 0.60 m. With fresh garden soil and manure in 3:1 proportion. Mixing soil and manure thoroughly well, leveling, as directed, watering previous night, planting one to two year old, minimum 1.0 mtr. Height, healthy tree sapling as per specifications. Maintaining till well established by watering, weeding, stirring of soil, staking, replacing of casualties etc. Complete.
Planting large flowering/shady trees: (Minimum height to 2 Mtr.) - Digging pit with size 0.9m x 0.9m x0.9mremoving and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material upto a height of 0.30 m and remaining height of 0.60 m. With fresh garden soil and manure in 3:1 proportion. Mixing soil and manure thoroughly well, levelling, as directed, watering previous night, planting two or three year old, minimum 2.0 mtr. Height, healthy trees sapling as per specifications. Maintaining till well established by watering, weeding, stirring of soil staking replacing of casualties etc. Complete.
Planting small & medium size Ornamental / Flowering plant: -Digging pit with size 0.6mx0.6mx0.6m. Removing & conveying unwanted stuff to a required distance as directed. Filling the pit with fresh garden soil & farmyard manure up to a height of 0.60 m. in 3:1 proportion. Mixing garden soil & manure thoroughly, well, leveling, watering on previous night. Planting one to two year old healthy tree saplings. Maintaining till well established by watering, weeding, stirring replacing of casualties etc. complete.
Preparing ground covers: Excavating the ground to a required depth of 20 cms. Removing and conveying unwanted stuff, rubbish to the required distance as directed. Filling the Excavated area with fresh garden soil and F.Y. Manure in 3:1 proportion to a height of 20 cms. Mixing, levelling, watering the same on previous night. Planting suitable ground covers as directed in staggering pattern distance between two rows 25 cms., watering & maintaining till well established.
Annual maintenance of garden from the date of completion, in all respect for keeping garden in all good condition such as wedning, sweeping, watering, manuring, cutting (lawn, hedges, trees, shrubs, flower beds etc.) & composting, Preparation of bed and Plantation of trees, shrubs, groundcover, flower bed, lawn etc & maintaining with security as per direction of Chief Garden Superintendant. For one year. (RA) 1000x 12 =15600sq m.
Handicap Toilet Block
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means (SSR 2019-20, I.No.21.02, P.No.197, Additional Specification Bd.A.1 Page No. 259)
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Spec.No. : Means Bd.A.2 Page No.259 (S. S. R. I. No. 21.06& P. No. 197)
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary backfilling with available earth / murum, ramming, watering including shoring and strutting etc. complete (lift upto1.5m ) By Mechanical Means (SSR 2019-20, I.No.21.14, P.No.198, Additional Specification Bd.A.4 Page No. 259)
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete. (SSR 2019-20, I.No.21.36, P.No.201, Additional Specification Bd.A.10 Page No. 262)
Filling in plinth and floors with contractors approved material / murum / stone dust in 15cm. to 20cm. layers including watering and compaction complete. (SSR 2019-20, I.No.21.37, P.No.201, Additional Specification Bd.A.10 Page No. 262)
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete. (SSR 2019-20, I.No.21.38, P.No.201, Additional Specification As directed by Engineer in charge.)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2019-20, I.No.24.01, P.No.225. Additional Specification Bd.E.2 Page No. 288 and B.7 Page No 38)
Providing and laying Cast in situ / Ready Mix cement concrete in M-15 of trap / granite / quartzite / gneis smetal for foundation and bedding including bailing out water, Steel centering, formwork, laying / pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Panmixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2019-20, I.No.24.04, P.No.226. Additional Specification Bd.E.2 Page No. 288 and B.7 Page No 38)
Providing and laying in situ / Ready Mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel ) etc. complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Panmixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2019-20, I.No.25.13, P.No.230. Additional Specification Bd.F.3 Page No. 298 and B.7, Page No.38)
Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying / pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give as mooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel ). with fully automatic microprocessor based PLCw ith SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer ) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2019-20, I.No.25.33, P.No.233. Additional Specification Bd.F.5 Page No. 300 and B-7,Page No 38.)
Providing and casting in situ cement concrete of M25 grade of trap / granite /quartzite /gneiss metal for R.C.C. beams and lintels as per detailed design and drawings or as directed,including steel centering, plywood/steel formwork steel props, compaction, finishing uneven and honeycombed surface with C.M.1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. Including use of plastisizer wherever necessary as directed by Engineer-In-charge (Excluding reinforcement, including cover block). The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (SSR 2019-20, I.No.25.52, P.No.235. Additional Specification Bd.F.5 Page No. 300 and B-7,Page No 38.)
Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, form work, cover blocks, laying / pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2019-20, I.No.26.07, P.No.239. Additional Specification Bd.F.9 Page No. 303 and B.7, Page No.38)
Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for R.C.C. Slabs and landings as per detailed designs and drawings including steel centering, form work, cover blocks, laying / pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel). with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (SSR 2019-20, I.No.25.72, P.No.236. Additional Specification Bd.F.8 Page No. 302 and B.7, Page No.38)
Providing and fixing in position TMT-FE-500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels, pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (SSR 2019-20, I.No.26.33, P.No.245. Additional Specification Bd.F.17, Page No. 306)
Providing second class Burnt Brick masonry with conventional / I.S.type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering complete (SSR 2019-20, I.No.27.03, P.No.254. Additional Specification Bd.G. 1 Page No. 313)
Providing second class Burnt Brick masonry with conventional / I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete (SSR 2019-20, I.No.27.05, P.No.254. Additional Specification Bd.G.5 Page No. 315)
Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:3 without neeru finish to concrete o rbrick surfaces, in all position including scaffolding and curing etc. complete. (SSR 2019-20, I.No.32.05, P.No.268. Additional Specification Bd.L.2 Page No. 368)
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rought or receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (SSR 2019-20, I.No.32.11, P.No.269. Additional Specification Bd.L.7 Page No. 369)
Providing and applying priming coat concrete/masonary/Asbestos cement plaster surfaces including scaffolding preparing the surfaces by throughly cleaning oil, grease, dirt and other foreign matter and sand papering as required. (SSR 2019-20, I.No.35.21, P.No.288. Additional Specification As directed by Engineer in charge.)
Providing and applying washable oil-bound distemper of approved colour and shade to old & new surfaces in three coats including scaffolding preparing the surfaces(excluding the prime coat.) complete. (SSR 2019-20, I.No.36.11, P.No.290. Additional Specification Bd. P.5 Page No. 413)
Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface ,applying primer coat ,scaffolding if necessary, and watering the surface for two days etc complete. NOTE: For Item No. 15 to 18 prior approval of Superintending Engineer will be necessary (SSR 2019-20, I.No.35.26, P.No.289. Additional Specification As directed by Engineer in charge.)
Providing preconstructional anti termite treatment as per I.S. 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper. (SSR 2019-20, I.No.21.22. P.No.199. Additional Specification As directed by Engineer in charge)
Providing preconstructional anti termite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. (SSR 2019-20, I.No.21.24. P.No.199. Additional Specification As directed by Engineer in charge)
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. (SSR 2019-20, I.No.40.01, P.No.338. Additional Specification Bd.U.1 Page No. 537)
Providing and fixing mild steel grill work for windows, ventilators, etc. 15 kg/sqm as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete.
Providing, laying and fixing P.V.C. pipe of 110 mm. dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SSR 2019-20, I.No.42.28, P.No.354. Additional Specification As directed by Engineer in charge.)
Providing waterproofing in W.C. and bath including brickbat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @1kg/per bag of cement laying brickbat coba of required thickness in cm1:5with waterproofing compound1kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound1kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamppaper including curing etc. complete. (S.S.R.2018-19 Item No 31.26 P.No.267, additional spec no. As directed by Engineer in Charge)
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. (S.S.R.2018-19 Item No 32.26 P.No.270, additional spec no. As directed by Engineer in Charge)
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. (SSR 2019-20, I.No.31.04. P.No.263. Additional Specification As directed by Engineer in charge)
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. (SSR 2019-20, I.No.32.34. P.No.272. Additional Specification As directed by Engineer in charge)
Providing and laying Antiskid Ceramic tile sof approved quality of size 30cmx30cma nd confirming toI S15622-2006(Group-BIIA) for antiskid flooring in required positionlaidonabedof1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. complete. (SSR 2019-20, I.No.33.67. P.No.283. Additional Specification Bd. M-12 page No. 385)
Providing and laying chequered tiles of approved qualityof size 30 cm x 30 cm, confirming to corresponding I.S.forflooring in required position laid on a bed of1:4 cement mortar including cement float,filling joint with cement slurry cleaning curing etc. complete. (SSR 2019-20, I.No.33.66. P.No.283. Additional Specification Bd. M-12 page No. 385)
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. (SSR 2019-20, I.No.39.68, P.No.331. Additional Specification As directed by Engineer incharge.)
Providing and laying vitrified mirror/glossy finish tile s having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to10 mm thickness and confirming to IS.15622-2006 (groupBla) of approved make,shade and pattern for dado and skirting inrequired position fixed in 1:4 cement mortar including neat cement float,filling joints,curingandclearing etc. complete. (SSR 2019-20, I.No.33.41, P.No.279. Additional Specification Bd.M. 12 Page No.385)
Providing and fixing green marble of 18 to 20 mm thick for doorframe/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing / moulding the sharp edges wherever necessary, curing, etc. complete. (SSR 2019-20, I.No.33.48, P.No.280. Additional Specification As directed by Engineer incharge.)
Providing and Fixing 30 MM thick BOTH SIDE PRELAMINATED SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S tubes of 19 guage thickness and, size 19 x 19 mm for styles and 15 x15 mm for the top and bottom rails, M.S frame shall have a coat of metel primer of approved make and manufacture. M.S frame shall be covered with heat mouled PVC 'C' channel made from 5 mm (+/0.25) thick prelaminated sheet of density 600 kg/cbm ,of size 30mm thickness 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45? angle on either side forming stiles ? and 5 mm thick ,95 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered in 45 on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be falt and 20 mm shall be tapered on both sides to form lock rail.Top,bottom and lock rail shall be provided either side of the panel. An additional 5 mm (+/0.25) thick PVC strip of 20 mm width is to be stuck on the bottom side of the ' c ' channel prelaminated paneling of 5 mm (+/0.25) thick PVC sheet to be fitted inside the M.S. frame welded/ sealed to the styles and rails with 5 mm (+/0.25) x 30 mm PVC sheet beading on either side and joined together with solvent cement adhesive etc ,10 mm thickness (5 mm (+/0.25) x 2 nos ) 20 mm wide cross PVC sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 nos M.S.powder coated but hinges of size 100 mm x 25MM x 2mm using 32 mm long steel screws drilled suitable to pass through both the walls of the M.S tube. Other hardwares should be fixed with 19 x 6 mm size steel screws including fixture fasting. Complete as per direction of engineer in charge (SSR 2019-20, I.No.39.47, P.No.326. Additional Specification As directed by Engineer incharge.)
Providing and fixing 450mmx550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. (SSR 2019-20, I.No.42.20, P.No.353. Additional Specification As directed by Engineer incharge.)
Grabbars-Providing S S grab bars set for accessible toilets comprising of 4 nos. Grabbars as specified below. (1nos. wing grab bar + 1nos. L shaped grab bar + 2nos. straight grabbars = 1typical set ) 27a) Swing grab bar(1NOS)Providing a S.S.304 SWING HANDICAP GRAB BAR-700 mm and of DIA: 32 MM and thickness 1.5 mm of the roved brand and make. 27b) L Shaped grabbar (1NOS) Providing S.S. 304 L SHAPED DISABLED GRABBAR of IZE-600 MM (H) X 600 MM (D) and 32 MM DIA. and thickness mm of the approved brand and make. 27c) Straight grab bar (2NOS) Providing S. STEEL 304 GRAB RAIL (600MM), 32 MM DIA. and thickness 1.5 mm of the approved brand and make. (SSR 2019-20, I.No.51.89, P.No.488. Additional Specification As directed by Engineer incharge.)
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5 mm thick at top, 40 mm diameter and 1.5mm thick vertical supports spaced at 1.5 M center to center and 8 mm thick toughened glass including fabricating, fixtures, errecting, necessary welding, grinding , finishing, buffing to stainless steel pipe etc. complete. (SSR 2019-20, I.No.40.07, P.No.339. Additional Specification As directed by Engineer incharge.)
Plumbing
Providing and fixing coloured glazed earthenware wash hand basin of 63 cm x 45 cm Size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. Spec. No. Bd.V.30 Page No.565 (SSR 2019-20, (I.No.41.74, P.No.349. Additional Specification Bd.V.30 Page No. 565.)
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No. As Directed By Engineer In Charge. (I.No.42.82, P.No.361. Additional Specification Bd.V.30 Page No. 565.)
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No. As Directed By Engineer In Charge. (I.No.42.79, P.No.361. Additional Specification As directed by engineer incharge. )
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. Spec. No. As directed by Engineer in charge (I.No.42.83, P.No.362. Additional Specification As directed by engineer incharge. )
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery upto destination hoisting and fixing of accessories such as inlet, outlet over flow of all tanks capacity above 1000 to 20,000 litres Spec. No. As directed by engineer incharge. (I.No.42.54, P.No.358. Additional Specification As directed by engineer incharge. )
Providing and fixing on Walls / Ceiling / Floor 25 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (I.No.42.63, P.No.359. Additional Specification As directed by engineer incharge. )
Providing and fixing on Walls / Ceiling / Floor 32 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (I.No.42.64, P.No.360. Additional Specification As directed by engineer incharge. )
Providing and fixing on Walls / Ceiling / Floor 40 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (I.No.42.59, P.No.359. Additional Specification As directed by engineer incharge. )
Providing and fixing on Walls / Ceiling / Floor 50 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (I.No.42.60, P.No.359. Additional Specification As directed by engineer incharge. )
Providing and fixing on Walls / Ceiling / Floor 15 mm Dia. CPVC Pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (I.No.42.55, P.No.358. Additional Specification As directed by engineer incharge. )
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (I.No.42.37, P.No.355. Additional Specification As directed by engineer incharge. )
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No. As Directed By Engineer In Charge. (I.No.42.36, P.No.355. Additional Specification As directed by engineer incharge. )
Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete (I.No.42.86, P.No.362. Additional Specification As directed by engineer incharge. )
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete chanels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75 kg with lid and frame fixed in cement concrete (I.No.42.11, P.No.352. Additional Specification As directed by engineer incharge. )
Solid waste disposal
Dustbin 240 Litre Blue WB-240 Dimensions : 725 x 580 x 1075 mm (107x72x58cm ) Heavy Duty Sunproof Waste Garbage Bins Wheeled Bins Easy to maintain & Use Envirnoment Friendly Long Lasting Capacity : 240 Litre (Non SSR)
Sedimentation tank
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. : Means Bd.A.1 Page No.259(S. S. R. I. No. 21.02 & P. No. 197)
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Spec.No. : Means Bd.A.2 Page No.259 (S. S. R. I. No. 21.06& P. No. 197)
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical Means. Spec.No. : Bd.A.3, Page No. 259. (S. S. R. I. No. 21.10 & P. No. 188)
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Spec.No. : Bd.A.4, Page No. 259.. (S. S. R. I. No. 21.14 & P. No. 188)
Filling in plinth and floors with approved excavated material in 15cm.to 20cm. layers including watering and compacting etc. complete. Spec. No Bd.A.10 Page No. 262 (S. S. R. I. No. 21.36 & P. No. 191)
Disposing of dismantling materials of R.C.C. stone/ brick masonry / derbies, excavated material etc from work site beyond the 5 km Spec. No.:As directed by Engineer in charge etc. complete. (Beed District D.S.R, Page No. 125, Sr. No. 486)
PLAIN CEMENT CONCRETE
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer incharge. (S. S. R. I. No. 21.40 & P. No. 201)
Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversibleDrum Type mixer/concrete Batch mix plant ( Pan mixer ) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) ) Spec. No. Bd. E. 1 Page No287 (S. S. R. I. No. 24.01 & P. No. 217)
REINFORCED CEMENT CONCRETE
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd. F.3 Page No. 298 and B.7, Page No. 38 (S. S. R. I. No. 25.13 & P. No. 222)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.. Spec. No. Bd.F.17 Page No. 306. (S. S. R. I. No. 26.33 & Page No. 236)
GROUND FLOOR
BRICK WORK -
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. Spec. No. Bd.G. 1. Page No. 313.
Providing Internal Cement Plaster 12mm Thick In Single Coat In Cement Mortar 1:4 Without Neeru Finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complet. Spec. No. Bd.L. 2 Page No. 368 (S. S. R. I. No. 32.04 & Page No. 260)
GROUND FLOOR
ELECTRO-MECHANICAL WORK
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-60 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-80 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-100 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-150 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-120 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications , for walls-min175 mm thick PIR panels,Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron)
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-60 mm thick PIR panels, Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside.
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-100 mm thick PIR panels, Density: 40 ±2kg /m3 , 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside. Additional PIR filled hat section of minimum 50 mm thicnkess beyond any metal member of the support should be considered if only metal 'T' is being considered for ceiling panel support.
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-150 mm thick PIR panels, Density: 40 ±2kg /m3 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside.
INSULATED PANEL Supply and Erection as per General Technical Specifications, for ceiling-min 175 mm thick PIR panels, Density: 40 ±2kg /m3 , 0.5 mm thick Precoated G.S. Sheet (min. 180 GSM) on both sides with polyester coating (thickness: 20~25 micron) Ceiling support system including supports for hanging/fixing ceiling structure from the roof/slab level to be included. This structure shall be ensured to be with complete thermal break and should avoid metal connection between inside and outside. Additional PIR filled hat section of minimum 50 mm thicnkess beyond any metal member of the support should be considered if only metal 'T' is being considered for ceiling panel support.
INSULATED FLOOR Supply and Erection as per General Technical Specifications Floor 75 mm XPS , min 30 kg/cu.m density. Rate for floor insulation to include supply and erection of all ancilliaries including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer, bitumin / bituminous cold compound for proper adhesion to surfaces.
INSULATED FLOOR Supply and Erection as per General Technical Specifications Floor 100 mm XPS , min 30 kg/cu.m density. Rate for floor insulation to include supply and erection of all ancilliaries including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer, bitumin / bituminous cold compound for proper adhesion to surfaces.
INSULATED FLOOR Supply and Erection as per General Technical Specifications Floor 150 mm XPS , min 30 kg/cu.m density. Rate for floor insulation to include supply and erection of all ancilliaries including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer, bitumin / bituminous cold compound for proper adhesion to surfaces.
INSULATED FLOOR Supply and Erection as per General Technical Specifications Floor 175 mm XPS , min 30 kg/cu.m density. Rate for floor insulation to include supply and erection of all ancilliaries including polythene vapour barrier & two ply tarfelt as per specifications and bituminous primer, bitumin / bituminous cold compound for proper adhesion to surfaces.
Supply & Fixing of 6~9 mm thick EPDM / Nitrile rubber on RCC slab / brick walls with suitable CPRX compound adhesive over which the insulated panels shall be fixed tightly with Nylon / FRP / Steel reinforced Nylon bolts.The bolt heads on the panels shall be covered with hat runners filled with PUF insulation as per standard practice.
Supply & fixing of of Al foil min. 50 micron on RCC slab / brick walls with suitable CPRX compound adhesive / bitumen
Ancillary Materials and Services - Flashings for Internal and external wall-ceiling joints and wall-wall joints as applicable or as may be required for doors or other openings. The layout showing the chamber dimensions and height is enclosed for ready reference. The flashings should be atleast 50mm x 50 mm or larger sizes with adequate overlap over any given panel-panel joint (Precoated G.S. Sheet, minimum 0.5 mm thick) for wall/ceiling panels: 7964 sqm
Ancillary Materials and Services - Silicon / Polyeurathene sealant for sealing the gaps between panels and the external / internal face of the insulation panels and any other location as may be deemed suitable for proper insulation panel erection system as applicable.for wall/ceiling panels: 7964 sqm
Ancillary Materials and Services - PUF/PIR chemical, adhesives,/ tapes / plastic caps etc reqd for onsite application, as may be necessary for a complete and foolproof insulation job. for wall/ceiling panels: 7964 sqm
Ancillary Materials and Services -SITC of Pressure relief ports suitable for mounting on insulated panels of various thicknesses (60 mm to 100 mm) with internal heaters for room temperatures ranging from 25 deg C to (-) 10 deg C. (Fermond Soupape 2220 -Valve /Equivalent)- 2 no for each cold storage chamber. 1 no for aril cold storage
Ancillary Materials and Services -SITC of Pressure relief ports suitable for mounting on insulated panels of various thicknesses (60 mm to 100 mm) with internal heaters for room temperatures ranging from 25 deg C to (-) 10 deg C. (Fermond Soupape 2230 -Valve /Equivalent)- 2 no for each cold storage chamber. 1 no for aril cold storage
Ancillary Materials and Services - Making & finishing of cut outs for doors, pipes, cables, pressure ports etc as per requirement at site. Finishing would include filling with PUF/PIR & PUF/PIR foam of required density and covering with pre - coated G.I.sheet from both side of the panels to give aesthetically neat joint acceptable to Consultants / Owners. This should also include any additional Silicon sealent or any other material as required.for wall/ceiling panels: 7964 sqm
Precooling Chamber 1,2,3 Staging cold room 1,2,3,4,5,6,7 Manual Sliding type 1500 mm x 2600 mm ht x 100 mm thick PIR , manual type, D1 Providing & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.5 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel wall to be included in the cost. The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing .
Insulated Sliding Doors for Blast Freezer (Manual) With 150 mm thick PIR Insulation , D2 Clear opening Size: 1500mm X 2100mm ht Providing & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel wall to be included in the cost. The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness.Counter frame (if required) shall also be provided at no extra cost. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing and shall have provision of self-regulating heat tracing / low voltage heating system. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
Insulated Sliding Doors for Frozen Food Chambers With 120 mm thick PIR Insulation , D3 Clear opening Size: 1500mm X 2100mm ht Providing & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel wall to be included in the cost. The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness.Counter frame (if required) shall also be provided at no extra cost. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing and shall have provision of self-regulating heat tracing / low voltage heating system. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
Processing area to ante room CS and Ante room to dispatch dock Manual Sliding type 2000 mm x 2600 mm ht x min. 80 mm thick PIR , manual type, D4 Providing & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.5 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel wall to be included in the cost. The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing .
For Entry to mango processing area & exit to ante-room Manual Sliding type 2000 mm x 2100 mm ht x min. 80 mm thick PIR , manual type, D5 Providing & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.5 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel wall to be included in the cost. The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing .
Emergency Exit Fire Doors, D6 Providing & fixing of hollow metal pressed steel FRD Doors made of 18 gauge frames of cross section100X 50& 40mm thk. Flush type door shutters made of 20 gauge sheet with vertical & horizontal channel stiffeners with Min Wool Insulation of suitable density, with2HRS Fire rated As per BS 476 / IS 3614 (With 4 nos. heavy duty SS ball bearing hinges (welded to hinge jams).With first class workmanship & alignment with a Powder coating finish.Accessories to be included are heavy duty door closer Dorma/ eqvt make, SS D Type Handle 600mm long Make Dorma/ eqvt, Dead Lock With Cylinder Make Dorma/eqvt, Vision Panel With Tuff Glass 200 X 300mm, Tower Bolt etc as may be required. Color of the door shall be as approved by owners/ architects. Clear opening Size 1000 mm x 2000 mm ht
For main office lobby to dispatch dock and dispatch/ receiving dock to dock office, LAb, Plant Quarantine, D7 Insulated Doors - Swing type with single leaf 1000 mm x 2000 mm ht x min 44 mm thick PIR /PUF Providing & fixing of Insulated doors (suitable for fitting on panel /civil structure) mounting of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manually operated single leaf swing type with 1.25 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame.Any other material for door frame may be considered on case to case basis. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR/PUF foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).Viewing window shall be provided. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
For Receiving to holding, holding to process area, holding to Aril, process area to aril,aril to aril Ante-room, D8 Insulated Doors -Swing type with double shutter 2000 mm x 2100 mm ht x min 44 mm thick PIR /PUF Providing & fixing of Insulated doors (suitable for fitting on panel / civil structure) mounting of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manually operated double leaf swing type with 1.25 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame.Any other material for door frame may be considered on case to case basis. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR/PUF foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).Viewing window on each door leaf shall be provided. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
For Packing material store, Dry storage, D10 Insulated Doors -Swing type with double shutter 2000 mm x 2100 mm ht x min 44 mm thick PIR /PUF Providing & fixing of Insulated doors (suitable for fitting on panel / civil structure) mounting of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manually operated double leaf swing type with 1.25 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame.Any other material for door frame may be considered on case to case basis. The door leaf shall have 0.6 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR/PUF foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).Viewing window on each door leaf shall be provided. The rate shall include all minor accessories not specifically mentioned in the technical specification, but essential for the completeness of the work.
For Changing Room, Pantry areas, Swing type with Single shutter clean room door 850 mm x 2100 mm ht Supply and Installation of flush doors made of 0.8mm thick 60-80 micron powder coated GI sheets with 30MM frame thickness, 1.2mm thick GPSP powder coated door frames modified to fit within different openings (minimum frame thickness 50MM), with ball bearing hinges, double glazing glass (400MM X 600MM) and hardware like SS D-Handle, concealed tower bolt for the double door, both side operated dead lock and key.The toilet doors shall be fitted with 600mm wide x 300mm high Grill at botom portion in Al powder coated / SS construction in finish acceptable to owners/architect.
Precooling Chamber & Cold Storage for Arils Manual Sliding type 1500 mm x 2100 mm ht x 100 mm thick PIR , manual type, D1 Providing & fixing of Insulated sliding doors (suitable for fitting on panel structure) of clear opening size & insulation thicknesses as mentioned and specifications as per General technical specifications (GTS). The doors shall be manual single leaf sliding with 0.6 mm thick SS-304 sheet or pre-coated extruded Aluminium of required thickness main frame. The door leaf shall have 0.5 mm thick PCGI sheet with min 180 GSM galvanising / S.S sheet cladding on both sides with PIR foam filled In-situ and with a density 40 ± 2 Kg/m3 (insulation thicknesses as mentioned).0.60mm thick PCGI sheet flashing to protect and reinforce the cut out opening in panel wall to be included in the cost. The sliding mechanism should be sturdy and smooth in operation complete with rail, runners, sill on the bottom etc. Rail shall be made of heavy duty aluminium alloy / SS with 45º drop & with polyethylene roller / special grade nylon arrangement runner system. The rail shall be provided with canopy / cover of 1.2 mm thick PCGI / Extruded Aluminium of required thickness. The doors shall have easily replaceable EPDM gaskets to ensure perfect hermetic sealing .
DOCK DOOR & SEAL Dock door shall be vertically moving with motorized movement. The shutter shall have PUF core with aluminum external / internal facing with white paint (RAL9003E/Eqvt). The vertical moving track shall be U shaped made of 2.5 mm G.S. Sheets. Full perimeters doors seal with PUF verticals, Vinyl lintel seal & rubber seal of bottom shall be provided. acceptable makes: Gandhi Automation/ Metaflex/Infraca/Eqvt (a) Dock door motorised type (b) Dock door motorized complete with control control button, manual lock release & cabling. DOCK DOOR: Type:motorised type Door opening Size : 2400 width x 2700 mm height Insulation : 40 mm PUF Door Movement : upwards, then curving into the ceiling Facing : External : Aluminium painted white Internal : Paint for higher impactability Operator : Normal Viewing Window: 1 no DOCK Seal : CUSHION type suitable for heavy duty operations for door opening size as above. Dock seal to have adjustable top vertical member so as to adjust for container height variations. Flexible polyurethane foam, covered with PVC / polyester fabric, supporting the vehicle pressures and perfectly sealing the three sides.
DOCK LEVELER Designed for Hydraulic operation in accordance of EN:1398 in steel construction as per General technical specification ,Acceptable makes: Gandhi Automation/ Metaflex/Infraca/Eqvt Size : 2000mm width and 2500mm deep, lift height min 300 mm from centre level, upwards & downwards., main cylinders-2 nos, All controls, control panels, controllers, power and control cabling,, pair of bumpers etc as required for full operation to be included
Strip Curtains: SITC of strip curtains made of 3 mm thick transparent PVC sheet strips with 40 / 50 mm overlapping and supporting clamps. The strips shall have free swinging motion. The strip material shall be suitable for the specified low temperature application to ensure that it remains soft even at the lowest operating temperature.
Precooling Chamber 1,2,3 Staging cold room 1,2,3,4,5,6,7 Suitable for Clear opening Size: 1500mm X 2600mm ht
Insulated Sliding Doors for Blast Freezer Suitable for Clear opening Size: 1500mm X 2100mm ht
Frozen Food Chambers Suitable for Clear opening Size: 1500mm X 2100mm ht
Processing area to ante room CS and Ante room to dispatch dock Suitable for Clear opening Size 2000 mm x 2600 mm ht
For Entry to mango processing area & exit to ante-room Suitable for Clear opening Size 2000 mm x 2100 mm ht
For main office lobby to dispatch dock and dispatch/ receiving dock to dock office, Lab, Plant Quarantine Suitable for Clear opening Size 1000 mm x 2000 mm ht
For Receiving to holding, holding to process area, holding to Aril, process area to aril,aril to aril Ante-room Suitable for Clear opening Size 2000 mm x 2100 mm ht
For Packing material store, Dry storage Suitable for Clear opening Size 2000 mm x 2100 mm ht
Precooling Chamber & Cold Storage for Arils Suitable for Clear opening Size 1500 mm x 2100 mm ht
AIR COOLED CONDENSING UNITS For Pre-Cooling chamber 1,2,3 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Pre-Cooling chamber 1,2,3 ( 2 nos for each ACU): Capacity: 43 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included There shall be provision to run each condensing unit separately especially in cases where product qty is low. Related controls (PLC if needed), cabling, panel, etc shall be included in the cost. This shoud be possible in Automode as well as manual mode.
AIR COOLING UNITS - Air Cooling Units for Pre-cooling chamber 1,2,3 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Twin coil type,Type of Refrigerant feed: HFO - DX Capacity - kW: 86, Evap. Temp. & TD ‘C’: (-)4 °C / 4 °C Coil / Fin MOC: Cu / Al, Fin spacing -mm: 6 mm Fin type: Plate, Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 92500, External sp. Wg, mm: 25 No of Fans/Unit: 3/4, Fan Motor -kW each: To be Mentioned Air throw -m: 8 m, Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: Electrical Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well. Product Covering Flap - Suitable product covering flap made of PVC sheet / EQVT sturdy material to be mounted on the unit above the fan(s) to ensure proper air flow through the produce. There shall be suitable reinforcement inside the flap as well as at the ends for supporting the Flap. Costing for the same also shall be included. It must be noted that this scheme is considered as a part of a combined pre-cooling system which will have an airtight plenum created between the wall panel and the area around the ACU as defined above. So while the insulated panel will be billed as per the the insulation panel rates, the cutting for the panel, the flashings, etc as needed for the pre-cooling unit arrangement should be considered while quoting the cost of panels.
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) For Pre-Cooling Chambers 1,2,3 The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.
Suction line insulation (General details as per PART – II- REFRIGERATION SYSTEM of GTS) For Pre-Cooling Chambers 1,2,3 Suction line insulation with EPDM/ XLPE/Equivalent insulation, class O with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection. Thickness - 25mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support (if necessary). This is essentially ensuring that the insulation compression at the support is at the minimum.
Drain piping For Pre-Cooling Chambers 1,2,3: with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
Controls and Instruments For Pre-Cooling Chambers 1,2,3 (a) Thermostatic expansion valves for each ACU coils. (b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each room in ante-room area. (e) Digital RH indicator (0 to 100 % range) for A.C. units to be placed outside the each cold rooms in ante-room area.
First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant. For Pre-Cooling Chambers 1,2,3 refrigeration system
Humidification system for pre-cooling chambers complete with Industrial type Ultrasonic Humidifier, U-PVC water piping from the tanks to humidifier unit, fitting ,valves, atomizer nozzles, solenoid valves with strainers and humidity controller with display etc as may be required. to maintain the relative humidity in the design range for Pre-Cooling Chambers. Also consider heavy duty PVC piping for air delivery into the cooling area for a release of humidified air into the main air stream, at atleast 1 m distance from the partition panel inside the cooling chamber area. Humidifier Capacity: 25 Lit/hr. For Pre-Cooling Chambers 1,2,3 refrigeration system
Charges for Installation, Testing and Commissioning For Pre-Cooling Chambers 1,2,3 refrigeration system Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
AIR COOLED CONDENSING UNITS For staging cold room 1 to 7(General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For staging cold room 1 to 7 Capacity: 23.4 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included There shall be provision to run each condensing unit separately especially in cases where product qty is low. Related controls (PLC if needed), cabling, panel, etc shall be included in the cost. This shoud be possible in Automode as well as manual mode.
AIR COOLING UNITS - Air Cooling Units for Staging cold room 1 to 7 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Twin coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 39 Evap. Temp. & TD ‘C’: (-) 4°C / 4 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 6 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 42000 External sp. Wg, mm: 7 No of Fans/Unit: 3/4/5 Fan Motor -kW each: To be Mentioned Air throw -m: 19 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: Electrical Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) staging cold room 1 to 7 refrigeration System The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.
Suction line insulation staging cold room 1 to 7 refrigeration System (General details as per PART – II- REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ XLPE/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection.Liquid line to be also insulated if distance btween indoor & outdor unit is more than 20m. Thickness - 25mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support (if necessary). This is essentially ensuring that the insulation compression at the support is at the minimum.
Drain piping staging cold room 1 to 7 refrigeration System: with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
Controls and Instruments Staging cold room 1 to 7 refrigeration System (a) Thermostatic expansion valves for each ACU coils (b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms in ante-room area. (e) Digital RH indicator (0 to 100 % range) for A.C. units to be placed outside the each cold rooms in ante-room area.
First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant for staging cold room 1 to 7 refrigeration System
Fabrication and Erection of the ducting. All ducts shall be fabricated from galvanized steel sheet . All nut bolts and washers shall be galvanized. Self tapping screw shall not be used.Duct construction shall, generally, conform to IS-655. All flanged joints shall have neoprene gasket. Ducting fabricated from G.S.sheet complete with collars, guide vanes, supports etc. as per approved drawings. 0.8 mm thick (22 gauge)
Charges for Installation, Testing and Commissioning for staging cold room 1 to 7 refrigeration System Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
AIR COOLED CONDENSING UNITS For Ante room (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Vibration eliminator, Base frame for mounting, H.P. / L.P. switches and pressure gauges etc. Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Ante room in front of staging cold rooms Capacity: 20.5 KW DesignTemperature: 5 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included
AIR COOLED CONDENSING UNITS For Ante room (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R513A / R450A or other approved HFO, , Air cooled condenser, Liquid receiver,Vibration eliminator, Base frame for mounting, H.P. / L.P. switches and pressure gauges etc. Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Ante room in front of Pre-cooling Capacity: 12.5 KW DesignTemperature: 5 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included
AIR COOLED CONDENSING UNITS For Dock Area (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R513A / R450A or other approved HFO, , Air cooled condenser, Liquid receiver,Vibration eliminator, Base frame for mounting, H.P. / L.P. switches and pressure gauges etc. Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Dock Area Capacity: 18.5 KW DesignTemperature: 10 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included
AIR COOLING UNITS - Air Cooling Units for Ante room (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 20.5 Evap. Temp. & TD ‘C’: 5 °C / 10 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 4 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 10700 External sp. Wg, mm: 8 No of Fans/Unit: 2/3/4 Fan Motor -kW each: To be Mentioned Air throw -m: 22 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: offcycle Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level to be considered in the costing as well.
AIR COOLING UNITS - Air Cooling Units for Ante room (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 12.5 Evap. Temp. & TD ‘C’: 5 °C / 10 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 4 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 6700 External sp. Wg, mm: 7 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 19 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: offcycle Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level to be considered in the costing as well.
AIR COOLING UNITS - Air Cooling Units for For Dock Area (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 18.5 Evap. Temp. & TD ‘C’: 10 °C / 10 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 4 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 9600 External sp. Wg, mm: 7 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 18 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: offcycle Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level to be considered in the costing as well.
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) For Ante-Room & Dock Area The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.
Suction line insulation For Ante-Room & Dock Area (General details as per PART – II- REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ XLPE/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection. Thickness - 25mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support (if necessary). This is essentially ensuring that the insulation compression at the support is at the minimum.
Drain piping For Ante-Room & Dock Area with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
Controls and Instruments For Ante-Room & Dock Area (a) Thermostatic expansion valves for each ACUs (b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms in ante-room area.
First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant For Ante-Room & Dock Area refrigeration system
Charges for Installation, Testing and Commissioning For Ante-Room & Dock Area refrigeration system Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
AIR COOLED CONDENSING UNITS For Pre-Cooling chamber for Aril (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Pre-Cooling chamber for Arils Capacity: 10.5 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included There shall be provision to run each condensing unit separately especially in cases where product qty is low. Related controls (PLC if needed), cabling, panel, etc shall be included in the cost. This shoud be possible in Automode as well as manual mode.
AIR COOLED CONDENSING UNITS For staging cold room for Arils (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For staging cold room for arils Capacity: 7 KW DesignTemperature: (-)4 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included There shall be provision to run each condensing unit separately especially in cases where product qty is low. Related controls (PLC if needed), cabling, panel, etc shall be included in the cost. This shoud be possible in Automode as well as manual mode.
AIR COOLED CONDENSING UNITS For Ante room for Arils (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R513A / R450A or other approved HFO, , Air cooled condenser, Liquid receiver,Vibration eliminator, Base frame for mounting, H.P. / L.P. switches and pressure gauges etc. Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For Ante room in front of Pre-cooling Capacity: 7.5 KW DesignTemperature: 5 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included
AIR COOLING UNITS - Air Cooling Units for Pre-cooling chamber for Arils (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Twin coil type,Type of Refrigerant feed: HFO - DX Capacity - kW: 21, Evap. Temp. & TD ‘C’: (-)4 °C / 4 °C Coil / Fin MOC: Cu / Al, Fin spacing -mm: 6 mm Fin type: Plate, Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 24500, External sp. Wg, mm: 20 No of Fans/Unit: 2/3, Fan Motor -kW each: To be Mentioned Air throw -m: 6 m, Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: Electrical Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well. Product Covering Flap - Suitable product covering flap made of PVC sheet / EQVT sturdy material to be mounted on the unit above the fan(s) to ensure proper air flow through the produce. There shall be suitable reinforcement inside the flap as well as at the ends for supporting the Flap. Costing for the same also shall be included. It must be noted that this scheme is considered as a part of a combined pre-cooling system which will have an airtight plenum created between the wall panel and the area around the ACU as defined above. So while the insulated panel will be billed as per the the insulation panel rates, the cutting for the panel, the flashings, etc as needed for the pre-cooling unit arrangement should be considered while quoting the cost of panels.
AIR COOLING UNITS - Air Cooling Units for cold room for arils (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 7 Evap. Temp. & TD ‘C’: (-) 4°C / 4 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 6 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 7500 External sp. Wg, mm: 4 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 6 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: Electrical Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
AIR COOLING UNITS - Air Cooling Units for Ante room (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 7.5 Evap. Temp. & TD ‘C’: 5 °C / 10 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 4 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 4300 External sp. Wg, mm: 6 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 15 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: offcycle Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level to be considered in the costing as well.
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) For Refrigeration System for Pre-cooling chamber, cold room and Ante-room for Arils The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.
Suction line insulation For Refrigeration System for Pre-cooling chamber, cold room and Ante-room for Arils(General details as per PART – II- REFRIGERATION SYSTEM of GTS) Suction line insulation with EPDM/ XLPE/Equivalent insulation, class O with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection. Thickness - 25mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support (if necessary). This is essentially ensuring that the insulation compression at the support is at the minimum.
Drain piping For Refrigeration System for Pre-cooling chamber, cold room and Ante-room for Arils with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
Controls and Instruments For Refrigeration System for Pre-cooling chamber, cold room and Ante-room for Arils (a) Thermostatic expansion valves for each ACU coils. (b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each room in ante-room area. (e) Digital RH indicator (0 to 100 % range) for A.C. units to be placed outside the each cold rooms in ante-room area. for pre-cooling & cold room only.
First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant For Refrigeration System for Pre-cooling chamber, cold room and Ante-room for Arils.
Humidification system for pre-cooling chambers complete with Industrial type Ultrasonic Humidifier, U-PVC water piping from the tanks to humidifier unit, fitting ,valves, atomizer nozzles, solenoid valves with strainers and humidity controller with display etc as may be required. to maintain the relative humidity in the design range for Pre-Cooling Chambers. Also consider heavy duty PVC piping for air delivery into the cooling area for a release of humidified air into the main air stream, at atleast 1 m distance from the partition panel inside the cooling chamber area. Humidifier Capacity: 5 Lit/hr.for pre-cooling chmaber for arils
Charges for Installation, Testing and Commissioning For Refrigeration System for Pre-cooling chamber, cold room and Ante-room for Arils Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
Compressor Rack for Blast Freezer (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Compressor rack with multiple compressors (semi-hermetic screw ) fitted on a skid with all necessary accessories. Minimum Compressors shall be 2Nos. No standby required. In case screw compressor offered, economiser (for individual compressors) with required accessories as may be required shall be included. Fully piped economisers with Insulated sub cooled liquid line with isolation valve preferred. Capacity control in terms of multiple compressors and stepless in case of screw compressor.Fully piped oil system complete with safety devices. Fully piped discharge lines to the oil separator High efficiency oil separator with level control, oil heaters, thermostat and sight glasses. Separate plate heat exchanger per compressor. Intelligent motor protection devices, thermal monitoring, phase sequence and restart time delay. Fully piped suction gas header/distributor oversized to give flood back protection.Integrated individual suction gas filters for each compressor. Adequately sized liquid receiver mounted on the frame with liquid level sight glasses, inlet and outlet isolation valves and pressure relief valve, Adequately sized liquid filter drier with filter cores, liquid line sight glass and moisture indicator. HP, LP & OP cutouts with manual override for LP Microprocessor Based control panel inclusive of all necessary electrical components etc. The compressor shall be suitable for the specified capacity as mentioned below,Other standard components as per manufacturers standard required for control logic including interlocks, HP/LP/OP cutouts and any other requirement for safety or as per good engineering practices shall be incorporated. It should be ensured that the microprocessor based controller can be linked up with PC through standard communication protocols.The capacity & other details of the unit shall be as under: Compressor Type: Semi-Hermetic Screw Make: Carrier / Bitzer / Bock / Frascold / RefComp / Eqvt No. of Compressors: 2/3 Refrigerant: R448a / R449a /other HFO. Total Refrigeration Capacity –kW: 105 KW (working) , Condensing Temp. (deg.C): 48 Deg C Evaporating Temp. (deg. C): (-) 36 Deg C, Economiser: to be provided Speed ( RPM ): To be mentioned, Power consumed at shaft (kW) total: To be mentioned, Capacity control (%): Step / Step less, Type of motor offered: High efficiency IE 2, Motor Insulation: Type F, Motor make: Siemens/ABB/Crompton / Eqvt, Economiser: to be provided, Microprocessror based control panel: to be included. The compressor rack shall be manufactured wholly by compressor OEM at their factory whose compressors are being used & preferabably shall be imported.
Air Cooled Condensers for Blast Freezer (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Air Cooled condenser, top discharge flat bed/ V-type/side discharge suitable for working on R448a/R449a/ other HFO refrigerant complete with inlet air precooling system as per specifications given in GTS. The capacity & other details of the unit shall be as under: Make: Alfa Laval / Thermofin / Guntner / Star Coolers & Condensers /Lu-Ve / Equivalent, Type -top discharge flat bed/ V-type/side discharge type as per site conditions Model: to be mentioned, Type - Induced / Forced: induced Heat rejection Capacity kW: 270 kW Condensing temp. (deg.C): 48°C, Ambient Dry bulb temp.(deg. C): 42°C , Ambient Wet bulb temp.(deg. C): 25°C, Total Estimated. Airflow Rate CMH: to be mentioned No. of Fans: to be mentioned, Fan Motor – Kw (each): to be mentioned, MOC of Casing: Powder coated G.S sheet Coil /Fin MOC: Cu/Al Rows Deep: 3/4, Total estimated. Coil surface area -m²: to be mentioned Coil test pressure kg/cm2 (pneumatic): 30, Inlet Air Pre-cooling system: to be provided Condenser to be designed considering ambient dry bulb temp. as air on temperature (coil to be esinged at 8deg C T), whereas the inlet Air Pre-cooling system will help in reducing power consumption.
AIR COOLED CONDENSING UNITS For FFS 1 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make two stage semi hermatic reciprocating compressor/compressors working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For FFS 1 Capacity: 15.5 KW DesignTemperature: (-)26 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included
AIR COOLED CONDENSING UNITS For Pre-processing Area (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semi hermatic reciprocating compressor working on R449A / R448 A or other approved HFO, Air cooled condenser, Liquid receiver,Oil separator with check valve in discharge line, Base frame for mounting, H.P. / L.P.switches, Suction accumulator Vibration eliminator, Oil pr switch and pressure gauges , Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows For Pre-processing Area Capacity: 12 KW DesignTemperature: (-)5 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included
AIR COOLING UNITS - Air Cooling Units for Blast Freezer 1 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Twin coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 105 Evap. Temp. & TD ‘C’: (-)36 °C / 6 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 10 mm/12 mm combination Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 105000 External sp. Wg, mm: 30 No of Fans/Unit: 3/4/5 Fan Motor -kW each: To be Mentioned Air throw -m: 5 m Drain pan insulation: Required Drain pan heating: Required Type of Defrosting: Electrical VFD for Fan motors:Required to be provided Fan peripheral heating: Required Suitable Supporting structure / mounting stand from floor level to be considered in the costing as well. False ceiling with min. 60 mm PIR panel with its support structure also shall be considered.
AIR COOLING UNITS - Air Cooling Units for FFS 1 (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: sinle coil type Type of Refrigerant feed: HFO - DX Capacity - 15.5 kW Evap. Temp. & TD ‘C’: (-)26 °C / 6 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 8 / 10 mm combination Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 13600 External sp. Wg, mm: 6 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 8 m Drain pan insulation: Required Drain pan heating: Required Type of Defrosting: Electrical Fan peripheral heating: Required Suitable Supporting structure from primary support at roof level or mounting stand (if supporting from floor level) to be considered in the costing as well.
AIR COOLING UNITS - Air Cooling Units for Frozen chamber Ante room (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 12 Evap. Temp. & TD ‘C’: (-)5 °C / 10 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 4 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 6450 External sp. Wg, mm: 6 No of Fans/Unit: 2/3 Fan Motor -kW each: To be Mentioned Air throw -m: 13 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: electrical Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level to be considered in the costing as well.
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) for Refrigeration System for Blast Freezer, Frozen Food Chamber & Pre-processing Area The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.
Suction line & Liquid Line insulation for Blast Freezer (General details as per PART – II- REFRIGERATION SYSTEM of GTS) for Refrigeration System for Blast Freezer, Frozen Food Chamber & Pre-processing Area Suction line insulation with EPDM/ XLPE/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with epoxy coating, with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection.Liquid line to be also insulated. Thickness for suction line - 65mm, Thickness for liquid line: 13mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support (if necessary). This is essentially ensuring that the insulation compression at the support is at the minimum.
Suction line & Liquid Line insulation for FFS (General details as per PART – II- REFRIGERATION SYSTEM of GTS) for Refrigeration System for Blast Freezer, Frozen Food Chamber & Pre-processing Area Suction line insulation with EPDM/ XLPE/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with epoxy coating, with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection.Liquid line to be also insulated. Thickness for suction line - 50mm, Thickness for liquid line: 13mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support (if necessary). This is essentially ensuring that the insulation compression at the support is at the minimum.
Suction line insulation for Ante-Room Units (General details as per PART – II- REFRIGERATION SYSTEM of GTS) for Refrigeration System for Blast Freezer, Frozen Food Chamber & Pre-processing Area Suction line insulation with EPDM/ XLPE/Equivalent insulation with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with epoxy coating, with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection. Thickness - 25mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support (if necessary). This is essentially ensuring that the insulation compression at the support is at the minimum.
Drain piping for Refrigeration System for Blast Freezer, Frozen Food Chamber & Pre-processing Area with rigid U-PVC / GI pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 25 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation. Drain line inside the chamber and 1m portion outside the chamber shall be in GI and shall have heat tracing for blast freezer and FFS.
Controls and Instruments for Refrigeration System for Blast Freezer, Frozen Food Chamber & Pre-processing Area (a) Electronic expansion valves for Blast Freezer coils ,DANFOSS (ETS or ETC or eqvt series) / Carel (E2V or E3V or eqvt series) / Eqvt. Make. controller for the same shall be able to integrated with the PLC panel for refrigeration system. along with all necessary cabling & accessories. (b) Thermostatic expansion valves for each ACU coils for FFS & ante-room (c) Digital temperature indicator cum controllers (0 to 50 deg. C range) (d) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (e) Digital temperature indicator (minus 20 to 50 deg. C range), for A.C. units to be placed outside the each cold rooms.
First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant for Refrigeration System for Blast Freezer, Frozen Food Chamber & Pre-processing Area
Charges for Installation, Testing and Commissioning for Refrigeration System for Blast Freezer, Frozen Food Chamber & Pre-processing Area Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
Compressor Rack for Aril Packaging Area Cooling (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Compressor rack with multiple compressors (semi hermatic reciprocating) fitted on a skid with all necessary accessories, microprocessor based control panel. Rack should have one compressor as stand by. Minimum Compressors shall be 3 Nos. The capacity & other details of the unit shall be as under: Compressor Type: Semi-Hermetic reciprocating Make: Carrier / Bitzer / Bock / Frascold / RefComp / Eqvt No. of Compressors: 3 (including 1 no stand by) Refrigerant: R448a /R449a / other HFO Total Refrigeration Capacity –kW: 100 KW (working) + standby Condensing Temp. (deg.C): 48 Deg C Evaporating Temp. (deg. C):5 Deg C Speed ( RPM ): To be mentioned Power consumed at shaft (kW) total: To be mentioned Type of motor offered: High efficiency IE 2 Motor Insulation: Type F Motor make: Siemens/ABB/Crompton / Eqvt Microprocessror based control panel: to be included. Capcity control: in terms of no of cmpressor operating & steps incase of indivudual compressor
Air Cooled Condensers (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Air Cooled condenser, side discharge type suitable for working on R448a/R449a/ other HFO refrigerant complete with inlet air precooling system as per specifications given in GTS. The capacity & other details of the unit shall be as under: Make: Alfa Laval / Thermofin / Guntner / Star Coolers & Condensers /Lu-Ve / Equivalent, Type -top discharge flat bed/ V-type/side discharge type as per site conditions Model: to be mentioned, Type - Induced / Forced: induced Heat rejection Capacity kW: 165 kW Condensing temp. (deg.C): 48°C, Ambient Dry bulb temp.(deg. C): 42°C , Ambient Wet bulb temp.(deg. C): 25°C, Total Estimated. Airflow Rate CMH: to be mentioned No. of Fans: to be mentioned, Fan Motor – Kw (each): to be mentioned, MOC of Casing: Powder coated G.S sheet Coil /Fin MOC: Cu/Al Rows Deep: 3/4, Total estimated. Coil surface area -m²: to be mentioned Coil test pressure kg/cm2 (pneumatic): 30, Inlet Air Pre-cooling system: to be provided Condenser to be designed considering ambient dry bulb temp. as air on temperature (coil to be esinged at 8deg C T), whereas the inlet Air Pre-cooling system will help in reducing power consumption.
AIR COOLED CONDENSING UNITS For TFA Unit (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Complete with Reputed approved make semihermatic compressor working on R513A / R450A or other approved HFO, , Air cooled condenser, Liquid receiver,Vibration eliminator, Base frame for mounting, H.P. / L.P. switches and pressure gauges etc. Sturdy MS Stand with two coats of primer and two coats of oil paint of approved colour etc. as required. Condenser coil to be designed for 10 deg C TD between ambient temperature and condensing temperature. Other Technical specifications as per General Technical specifications as mentioned in the tender. The capacity and other details shall be as follows : For TFA Unit Capacity: 35 KW DesignTemperature: 5 deg. C evap. and +48 deg.C cond. Temp Maximum ambient Temperature: 42 deg C ambient Minimum fin spacing: 2 mm Condensing unit inlet air pre-cooling system: to be included There shall be provision to run each condensing unit separately especially in cases where product qty is low. Related controls (PLC if needed), cabling, panel, etc shall be included in the cost. This shoud be possible in Automode as well as manual mode.
AIR COOLING UNITS - Air Cooling Units for Aril Packing Area Cooling (General details as per PART – II - REFRIGERATION SYSTEM of GTS) Technical specifications as per General Technical Specifications as mentioned in the tender. The capacity and other details shall be as follows : Make: Star coolers / GEA / Alfa Laval / Guentner / LU-VE / Thermofin / Eqvt, Model: To be Mentioned Type of Unit -Single / Twin: Single coil type Type of Refrigerant feed: HFO - DX Capacity - kW: 23 Evap. Temp. & TD ‘C’: 5 °C / 10 °C Coil / Fin MOC: Cu / Al Fin spacing -mm: 4 mm Fin type: Plate Finned coil length -m: To be Mentioned Total fan capacity of each unit– CMH: 12100 External sp. Wg, mm: 8 No of Fans/Unit: 1/2 Fan Motor -kW each: To be Mentioned Fans: Fans shall be low noise type Air throw -m: 16 m Drain pan insulation: Required Drain pan heating: Not required Type of Defrosting: offcycle Fan peripheral heating: Not required Suitable Supporting structure from primary support at roof level to be considered in the costing as well.
TREATED FRESH AIR UNIT Treated Fresh Air Units including blower, inlet and outlet connections. The units shall be powder coated double skinned with 0.6 mm thk inner and outer skin including PUF insulation 50 mm thk between,The unit shall be complete with Pre filter section,Fine filter,section, DX-Cooling coil section, Supply air Fan section, etc. Capacity: 2890 cmh (1700 cfm)
Rigid U-PVC piping for treated fresh air from TFA unit to A.C. units suction complete with necessary fixtures and fitting such as bends, tees, clamps etc.supports & 19 mm EPDM / Eqvt. insulation with factory backed Aluminium foil. 250mm dia pipe
Rigid PVC piping for treated fresh air from TFA unit to A.C. units suction complete with necessary fixtures and fitting such as bends, tees, clamps etc.supports & 25 mm EPDM / Eqvt. insulation with factory backed Aluminium foil. 200mm dia pipe
Rigid PVC piping for treated fresh air from TFA unit to A.C. units suction complete with necessary fixtures and fitting such as bends, tees, clamps etc.supports & 25 mm EPDM / Eqvt. insulation with factory backed Aluminium foil. 150mm dia pipe
Rigid PVC piping for treated fresh air from TFA unit to A.C. units suction complete with necessary fixtures and fitting such as bends, tees, clamps etc.supports & 25 mm EPDM / Eqvt. insulation with factory backed Aluminium foil. 100mm dia pipe
SITC of Ball Valves of 250 NB for fresh air flow control in polypropelene construction for air flow control duly insulated with 25 mm thk EPDM / Nitrile foam with factory backed aluminium foil
SITC of Ball Valves of 100 NB for fresh air flow control in polypropelene construction for air flow control duly insulated with 25 mm thk EPDM / Nitrile foam with factory backed aluminium foil
PART IV- VENTILATION SYSTEM - Refrigeration System for Aril Packaging Area Cooling Factory fabricated Air Ducting for ventilation system (round /spiral) with GI sheets as per IS 655 standard duly painted as per the shade required by the architect and insulated with 19 mm EPDM / Nitrile rubber / XLPE insulation , Class O with factory backed aluminium foil applied using suitable self adhesive from the inside of the duct. Duct shall be made of pre-coated /pre-painted color sheets of color as approved by owners/ architects for good asthetic look. All necessary supports, etc to be included in the rate. 22 gauge (0.8 mm)
PART IV- VENTILATION SYSTEM - Refrigeration System for Aril Packaging Area Cooling Factory fabricated Air Ducting for ventilation system (round /spiral) with GI sheets as per IS 655 standard duly painted as per the shade required by the architect and insulated with 19 mm EPDM / Nitrile rubber / XLPE insulation , Class O with factory backed aluminium foil applied using suitable self adhesive from the inside of the duct. Duct shall be made of pre-coated /pre-painted color sheets of color as approved by owners/ architects for good asthetic look. All necessary supports, etc to be included in the rate. 24 gauge (0.63 mm)
PART IV- VENTILATION SYSTEM - Refrigeration System for Aril Packaging Area Cooling Supply and installation of supply air linear grills in aluminium powder coated construction with with shade as required by architect along with matt finish aluminium dampers for sizes as may be required.
Supply and Erection of Acoustic Insulation for duct-Refrigeration System for Aril Packaging Area Cooling: ducting (including branches) shall have acoustic lining Acoustic lining with 10 mm Armasound or Equivalent material.applied using suitable self adhesive
Refrigeration Piping, Fittings & Valves (General details as per PART – II- REFRIGERATION SYSTEM of GTS) for Refrigeration System for Aril Packaging Area Cooling The piping shall be of refrigeration quality The piping shall be of refrigeration quality seamless copper tubes and the valves shall be brassomatic / Henry or equivalent make. The piping shall be included accessories such as filter, drier, sight glass, heat exchanger, suction lineaccumulator etc. as per P & I diagram approved by Consultant. Adequate number of supports shall be included. The piping shall be supported at distances of maximum 1.5 m from each other with suitably placed GS threaded rods of minimum 6 mm thickness when outside the chamber and piping shall be run on cable trays of size suitable to fit the pipes including insulation. Common cable trays can be considered depending on the suitability at site, however the same shall be acceptable to the consultant / owner. Overall, the piping execution shall ensure proper workmanship and a neat and tidy work is expected with straight horizontal and vertical lines and proper supporting. Under no circumstances shall any additional charges be demanded by the contractor for ensuring the same. The suction and discharge lines shall be designed for a maximum pressure drop corresponding to 1.1 deg. C drop in saturated evaporating and condensing temperatures. The liquid line shall be designed for maximum pressure drop corresponding to a drop 0.5 to 1 deg. C in saturation temperature. The piping shall be designed with proper slope in the direction of Refrigerant flow and to ensure proper oil return to the compressor and should be installed with adequate supports to avoid undue vibration. The piping should be thoroughly cleaned as per standard practice prior to installation. Refrigeration piping,fittings,valves,interconnecting condensing & evaporator unit complete with standard controls & accessories, supports as may be required shall be included in cost.layout drawing showing proposed location of condesing units is atttached for your reference.
Suction line insulation (General details as per PART – II- REFRIGERATION SYSTEM of GTS) For Refrigeration System for Aril Packaging Area Cooling Suction line insulation with EPDM/ XLPE/Equivalent insulation, class O with minimum 28G Aluminium foil Clading in the covered areas and Weatherproof Clading in areas exposed to sunlight and is uncovered ; e.g. Woven glass cloth with epoxy coating or Armacheck GC/equivalent Clading with suitable fittings and Adhesives.Alternatively,Fevicol Weather protect coat applied as per manufacturers recommendation may be used for entire insulton protection. Thickness - 25mm Insulation supports shall be half round or full round heavy duty PVC pipe sections of relevant size which shall be atleast 150 mm in length and shall be placed below every support (if necessary). This is essentially ensuring that the insulation compression at the support is at the minimum.
Drain piping For Refrigeration System for Aril Packaging Area Cooling with rigid U-PVC pipe from A.C. units to to suitable drain point complete with 'U' Traps for each cold room and supports.Drain lines (inside the chambers) to have 10 mm EPDM / Eqvt. insulation with factory backed Aluminium foil.Individiual Drain outlet line from ACU pipe size shall be same as the drain outlet of ACU and further the header shall be at least one size higher than the drain outlet connection size. Further, higher sizes may be considered as per the consultants/owner's recommendation
Controls and Instruments For Refrigeration System for Aril Packaging Area Cooling (a) Thermostatic expansion valves for each ACU coils. (b) Digital temperature indicator cum controllers (0 to 50 deg. C range) (c) Liquid line solenoid valves, DANFOSS / SPORLAN /EQVT make (d) Digital temperature indicator (minus 20 to 50 deg. C range) (e) Digital RH indicator (0 to 100 % range)
First charge refrigeration gas and oil etc. as required upto commissioning and final handling over of plant For Refrigeration System for Aril Packaging Area Cooling
Charges for Installation, Testing and Commissioning For Refrigeration System for Aril Packaging Area Cooling Installation, testing and commissioning of all above equipment / material as per the system requirement. All tools and tackles, welding machines, welding rods and gases etc. required for fabrication, erection, testing and commissioning shall be arranged by the contractor at his cost. The plant shall be erected, tested, commissioned as per Consultant's approved drawings / specifications and instructions to his and Employer's satisfaction. The refrigeration system shall be pressure tested and evacuated as per standard practice before charging the refrigerant. The water lines shall also be pressure tested as per standard practice. The plant shall be run for a period of three days after commoissioning by the contractor, to assess the plant performance. The contractor shall provide 3 hard copies of operation & maintenance for the plant along with as built drawings. The contractor shall also arrange the training of the operating staff for proper operation & maintenance of the plant (included in above rates)
Painting of equipment/piping / piping supports etc. as per standard colour codes with initial coat of red oxide primer and two coats of synthetic enamel paint .for all refrigeration plant
Vibration isolators for condensing units, supporting rods / Frame for A.C. Units with insulation, steel structure for mouting condensing units etc (single storied/ multi storied as per site condition). as may be required For entire project
Minor structural openings in walls / panels etc for piping, cabling etc. and finishing for entire project
1000 lit water tank along with water pump as necessary for lifting water to the tank or lifting water from the tank depending on tank location ,UPVC piping, fittings,valves etc as may be required for condenser inlet air-precooling system. Condenser air pre-cooling system shall have automatic operation with water line sonenoid valves for each individual condensing unit and there shall be an interlock with the conensing unit start/stop as well as the ambiend air temperature wherein the air precooling system starts only after the ambient air temperature crosses 33 deg C and switches off when ambient goes beloe 33 deg C.
SITC of 3 LAYER CONVEYOR SYSTEM for grapes with Top belt for punnet, middle boxes conveyor & bottom empty crates conveyor. estimated length:25 m For Grading Sorting Packing Line for Grapes Acceptable make: Locus systems / Kailash Engg. / Fruit technologies / eqvt apporved The conveyor shall be complete with Side Member [“C” Channel] in S.S. [2mm Thick Sheet] , S.S. 304 [1.2 Mm Thick] Conveyor Top Plate [Below The Belt], Belt Thcknes Is - 3 Mm [Food Grade] 500 Mm Width Make- Ntb /eqvt approved, Motor & Gear Box Are Bonfigulily / eqvt approved make (1hp), All S.S Material used shall be CNC Punching & Bending . VFD Or Drive to be Provided For Conveyor Speed [Delta / eqvt approved Make] Bottom Pvc Rollers For Belt Support – 2 Rollers Per 2mtr [Dia 45 X 550 Mm] Conveyor Bearings Make – Fag Or Ntn or eqvt apporved Make Conveyor Drum, H/W & Its Mouting Brackets to be Plated. 20 Single Sockets Point For Weighing Scale & Its Wiring [with Fire Proof Cables] Darshana / eqvt apporved Make Level Pads For Height Adjustment. Required electrical ocntrol panel in SS construction with related power, control cabling etc shall be included in the cost.
SITC of PVC ROLLER CONVEYOR FOR CRATES estimated length: 20m, For Grading Sorting Packing Line for Grapes Acceptable make: Locus systems / Kailash Engg. / Fruit technologies / eqvt apporved Side Member [“C” Angle] Is In S.S. [2mm Thick Sheet] All SS Material shall be with Punching & Bending & powder coated PVC Pipe with 4 mm Thickness Make Dutron / eqvt apporved Pictch Between Two Roller to be 150 mm Roller Size: 45 Mm X 500 Mm Internal MS Plated Shaft :12 Mm Dia Conveyor Bearings Make – Korean / eqvt apporoved Make Conveyor H/W : MS Plated 304
WEIGHING TABLES (1800mm x 600mm x 800mm ht) For Grading Sorting Packing Line for Grapes SS top plate 1.5 mm thick [SS304] SS square pipe size 30mm x 30 mm x 2mm thk level pads shall be provided
CARTON BOX PACKAGING TABLES (1800x600) For Grading Sorting Packing Line for Grapes SS top plate 1.5 mm thick [SS304] SS square pipe size 30mm x 30 mm x 2mm thk level pads shall be provided
SITC of LABLE APPLICATOR, For Grading Sorting Packing Line for Grapes Acceptable make: Locus systems / eqvt apporved Dispensing speed 230 sticker/min. [depends upon label size] Label height upto 4 inch Servo systems make :DELTA / eqvt approved All head components are made in S.S 304 & stand is made in SS pipe structured. The unit shall have Low maintenance. 4 inch HMI for User Friendliness shall be provided. Automatic speed synchronization by integration using Rotary Encoder.
Weighing balance with pole display of 20 Kg. each digital type,acceptable make: Sansui / Eqvt For Grading Sorting Packing Line for Grapes
GRAVITY ROLLER CONVEYOR Grading, Sorting, washing & packing Line for Banana: Size : - 600 mm (width) x 2000 mm (length) x 900 mm (feed ht) MOC : - SS304, Channel shall be made from sheet in 2.5 mm thk.All frame structure shall be manufactured in square tube having thickness 2 mm. Rollers shall be provided to conveyor for empty basket transport. The rollers shall be made with SS304 Ø 51 mm x 2 mm thickness. Pipe with teflon bush at both end of pipe. 1/2” SS rods with locking arrangement. The remaining base structure shall be made up of Sq. Tube of size 40 x 2 mm thk. It shall stand on leveling studs which provide (+/-50mm) leveling adjustment. All argon arc welding joints shall be ground smooth and polished with 150 grit paper to dairy standard. Material test certificate, Pre inspection certificate shall be provided before dispatch of the material in prescribed format. Acceptable make: Kailash Engg. / Fruit technologies / Locus systems / eqvt apporved
HAND SEPERATOR CUM INSPECTION BELT CONVEYOR WITH CUTTING TABLES for Grading, Sorting, washing & packing Line for Banana Size : - 600 mm (width) x 7000 mm (length) x 900 mm (feed ht) MOC : - SS304, Channels shall be made from sheet in 2.5 mm thk. All frame structure shall be manufactured in square tube having thickness 2 mm. It shall stand on leveling studs which provide (+/-50mm) leveling adjustment. PP Modular plain food grade quality inspection belt with white color.With Square bore id 40 x 40 mm sprockets. Operation/ Maintenance manual shall be submitted. Fabricated welded Joints ground smooth grinded and Polished to 150 matt finishes. Electrical load : 1 HP SEW/Bonfiglioli/ Other Equivalent make gearbox. CUTTING TABLE: 6 nos. Acceptable make: Kailash Engg. / Fruit technologies / Locus systems / eqvt apporved
BELT CONVEYOR FEED TO WASHER for Grading, Sorting, washing & packing Line for Banana Size : - 700 mm (width) x 2500 mm (angular length) x 900 mm (height) MOC : - SS304, Channels shall be made from sheet in 2 mm thk. All frame structure shall be manufactured in square tube having thickness 2 mm. It shall stand on leveling studs which provide (+/-50mm) leveling adjustment. Rollers provide to conveyor for empty basket transport. These rollers construct in round bar, pipe & etc. Electrical load: Gear box 1 HP SEW / Bonfiglioli / Other equivalent make drive. Acceptable make: Kailash Engg. / Fruit technologies / Locus systems / eqvt apporved
BANANA WASHING MACHINE 1 for Grading, Sorting, washing & packing Line for Banana Size: 700 mm (w) x 3600 mm (L) x 900 mm (ht) MOC : - SS304, Assembly of washer tank manufactured in sheet having thickness 2.5 mm. All frame structure shall be manufactured in square tube. Header with nozzles shall be provided to spray water on product.Also, washer with circulation pump for pushing the material towards the discharge elevator shall be provided. In line filter system will be attached in water circulation system required. Line nozzles are given on elevator for fresh water spray. Modular belt is given to take off the material and feed to second washer. Air Blower to be provided for agitation. Fabricated welded Joints ground smooth grinded and Polished to 150 matt finishes. Operation/ Maintenance manual shall be submitted. Material Test certificate, Pre-Inspection certificate shall be provided before dispatch in prescribed format. Electrical load : - Gear box 1 HP SEW / Bonfigloli / Other equivalent make drive. Pump 3 HP for water circulation. Blower 2 HP. Acceptable make: Kailash Engg. / Fruit technologies / Locus systems / eqvt apporved
BANANA WASHING MACHINE 2 for Grading, Sorting, washing & packing Line for Banana Size: 700 mm (w) x 3600 mm (L) x 900 mm (ht) MOC : - SS304, Assembly of washer tank manufacture in sheet having thickness 2.5 mm.All frame structure shall be manufactured in square tube.Header with nozzles to spray water on product shall be provided. also,washer with circulation pump for pushing the material towards the discharge elevator shall be provided. In line filter system will be attached in water circulationn.Line nozzles are given on elevator for fresh water spray. chemical dosing pump required to be provided. Modular belt is to take off the material and feed to dryer. Air Blower to be provided for agitation. Fabricated welded Joints ground smooth grinded and Polished to 150 matt finishes. Operation/ Maintenance manual shall be submitted. Material Test certificate, Pre-Inspection certificate shall be provided before dispatch in prescribed format. Electrical load : - Gear box 1 HP SEW / Bonfigloli / Other equivalent make drive. Pump 3 HP for water circulation.Blower 2 HP. Acceptable make: Kailash Engg. / Fruit technologies / Locus systems / eqvt apporved
BANANA DRYER WITH CONVEYOR for Grading, Sorting, washing & packing Line for Banana Size : - 700 mm (width) x 3000 mm (length) x 950 mm (feed ht) MOC : - SS304., Side channel of roller conveyor having thickness 2.5 mm.All frame structure ihall be manufactured in square tube having thickness 2 mm. It shall stand on leveling studs which provide (+/-50mm) leveling adjustment. Modular belt to be provided to conveyor. Sprockets to be provided at drive & non drive end having size Ø160 mm with square bore id 40 x40 mm. Fan shall be provided on top of the conveyor to dray the product. All structure of fan hold on conveyor in sheet having thickness 1.6 mm. Fabricated welded Joints ground smooth grinded and Polished to 150 matt finishes. Operation/ Maintenance manual shall be submitted. Electrical load : 1 HP SEW/Bonfiglioli / Other equivalent make gearbox. Acceptable make: Kailash Engg. / Fruit technologies / Locus systems / eqvt apporved
BANANA PACKING WITH CONVEYOR for Grading, Sorting, washing & packing Line for Banana Size : - 600 mm (width) x 7000 mm (length) x 900 mm (feed ht) MOC : - SS304 Channel made from sheet in 2.5 mm thk.All frame structure shall be manufactured in square tube having thickness 2 mm.It shall stand on leveling studs which provide (+/-50mm) leveling adjustment. PVC food grade belt provide to the conveyor. Operation/ Maintenance manual shall be submitted. Fabricated welded Joints ground smooth grinded and Polished to150 matt finishes. Electrical load : 1 HP SEW/Bonfiglioli / Other equivalent make gearbox. PACKING TABLE: 4 nos M.O.C.: S.S.304, Table Size: 4’ x 8’ long, VACCUM MACHINE: 3 nos, WEIGHING SCALE: 5 Kg’s machine - 3 nos. Acceptable make: Kailash Engg. / Fruit technologies / Locus systems / eqvt apporved
ELECTRICAL WORK for Grading, Sorting, washing & packing Line for Banana Panel body construct S.S.304 Electrical panel shall contain starter for all other motors with respective H.P. with on/off switch, emergency stop button, Push button & relay, RYB indicators & Emergency stop button. Related power & control cabling, earthing etc shall be included in the cost. SS cable trays/ conduits shall be used.
SORTING TABLE 8'X4'X3' for Grading sorting & Packing Line for Pomogranates M.O.C.: S.S.304 Table top in 2 mm thk with support frame in sq tube 40 x 40 mm and verticle legs having bottom PP bush.Table top shall have drain point at one end with dead plug. Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
INSPECTION BELT CONVEYOR for Grading sorting & Packing Line for Pomogranates M.O.C.: S.S.304. Size: 1000 mm (width) x 7500 mm (length) x 1160 mm (Height). Conveyor shall have divider for easily sort the fruits. Channel made from sheet in 2 mm thickness. S.S structure of square tube. It shall stand on leveling studs which provide (+/- 50 mm) leveling adjustment. PVC food grade quality inspection belt with white colour. Electrical Drive: 2 H.P. Make SEW / Bonfiglioli / eqvt Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
ROPE GRADER for Grading sorting & Packing Line for Pomogranates M.O.C.: S.S.304. Size: 1200 mm (w) x 3000 mm (L) x 800 mm (ht.) Continuous grader in three grading system. 1st section grading size: 45 mm to 60 mm 2nd section grading size: 60 mm to 70 mm 3rd at outlet grading size: more than 70 mm size Infeed material will collect from vibratory feeder. Grading done by PU food graded wire rope Dia. 10 mm mounts on pulley with on specific gap. Wire rope having electrcal drive by gearbox. VFD shall be provided for speed control. Graded material will collect at bottom side. Bottom collection in S.S. construction sheet. Electrical load: 1 HP Make SEW/Bonfiglioli Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
PACKING CONVEYOR for Grading sorting & Packing Line for Pomogranates MOC: SS304 Size: 300 mm (width) x 2500 mm (length) x 1000 mm (feeding ht) Channel made from sheet in 2 mm thk. All frame structure is manufacture in square tube having thickness 2 mm. It shall stand on leveling studs which provide (+/-50mm) leveling adjustment. PVC food grade belt to be provided to the conveyor. Sprockets shall be provided at drive & non drive end having size Ø160 mm with square bore id 40 x40 mm. Electrical load : 1 HP Make SEW/Bonfiglioli /eqvt. Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
ELECTRICAL CONTROL PANEL for Grading sorting & Packing Line for Pomogranates Panel body construct in SS 304. Electrical panel contains V.F.D. for inspection belt conveyor only. Electrical panel shall contain starter for all other motors with respective H.P., emergency stop button, on/off switch, RYB indicator etc. Related power & control cabling, earthing etc shall be included in the cost. SS cable trays/ conduits shall be used.
FRUIT FEEDING BELT CONVEYOR for Pomegranate Aril processing Line MOC- SS 304., Size: 400 mm (w) x 3000 mm (l) x 1000 mm ht, Channel made from sheet on both side of belt with providing 75 mm depth from belt top. PVC food grade quality inspection belt. Outlet chute with Teflon scrapper for belt cleaning shall be provided at the discharge of conveyor. Leg structure made by sq. tube with level adjustment ball fits. Conveyor having feed hopper with minimum possible height to prevent the material spillage during the loading. Electrical load: 1 hp Make SEW/ Bonfiglioli./eqvt approved make Finishing: All parts will be finished to 180 grit Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
FRUIT WASHER for Pomegranate Aril processing Line MOC: SS 304. Size: 700 mm (w) x 3500 mm (L) x 1100 mm (ht). Tank shape to be such that to give easy discharge of water. Necessary inlet and outlet of water with valves and unions shall be provided. Modular perforated belt elevator shall be in built for effective removal of product from the washing tank. Inside the tank, belt having both side S.S. capsule perforated guards to avoide spillage. Capsule size is 6 x 30 mm long with standard triangular pitch. Tank consist of normal water for washing the product. The final spray wash is also provided on the top of the elevator will be RO water washing. Washer have water filtration tank with double screening filtration effect. 1st filtraion sieve hole perforation size will be dia. 3 mm & 2nd will be dia. 1.5 mm hole size. Electrical load: 2 HP & Make SEW / Bonfiglioli, (VFD drive), Pump 3 HP Make Wilo/IPP / eqvt Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
TWO TIER CUTTING BELT CONVEYOR for Pomegranate Aril processing Line MOC: Contact parts in S.S.316 & non-contact parts in SS 304. Size: 600 mm (w) x 5000 mm (L) x 1100 mm (ht).- Bottom belt 300 mm (w) x 5000 mm (L) x 1400 mm (ht) - Top belt Bottom belt carrying the washed fruits and cut head & tail of fruit by manual. Top belt carryig the fruit without head & tail for to feed next marigo belt. Channel made from sheet on both side of belt with providing side cutting pad on both side of conveyor.PVC food grade quality inspection belt. Conveyor both side removable wastage chutes 3 + 3 no's. Conveyor outlet chute with Teflon scrapper for belt cleaning will be provided at the discharge of conveyor. Leg structure made by sq. tube with level adjustment ball fits. Electrical load:1 + 0.5 hp hp Make SEW/ Bonfiglioli/ eqvt Finishing: All parts will be finished to 180 grit. Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
THREE TIER MERIGO ROUND BELT CONVEYOR for Pomegranate Aril processing Line MOC: Contact parts in S.S.316 & non-contact parts in SS 304. Top Belt: Size: 300 mm (width) x 7000 mm (length). Top belt carry only the finish good Ariels to the next process. Middle belt: Size: 300 mm (w) x 7000 mm (l) x 1200 mm (Height) (QTY. 2 NOS). (Merigo round belt) Carrying the fruits towrds the opposite direction of each other. End Transfer Belt conveyors- 2 No's. Size: 300 mm (w) x 1200 mm (L) Inclined trasfer belt conveyor at end both side: - 2 No's Bottom belt: Size: 300 mm (width) x 7000 mm (length) x 400 mm (Height). S.S.structure of square tube & channel made from sheet. Wastage collection chute construct in 1.2 mm thickness. All belts are PVC food grade quality inspection belt. Rigid square tube structure with platform. Platform with aluminium chequered plate for standing on conveyor with both side ladder & safety railing. Electrical load: 1 hp for top belt, 1 + 1 hp for middle belt & 1 hp for All belt having electrical drive of SEW / Bonfiglioli Total electrical load: 1+ 1 + 1 + 1 + 0.5 hp + 0.5 ho = 5 HP. Electrical contol panel construct in S.S.material. Panel consist V.F.D. for middle belt drive, starter for all other motors with respective H.P., on/off switch, emergency stop button,RYB indicator etc. Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
WASTAGE BELT CONVEYOR for Pomegranate Aril processing Line MOC- SS 304. Size: 300 mm (w) x 12000 mm (l) x 1000 mm ht Conveyor carrying waste. Channel made from sheet on both side of belt. PVC food grade quality inspection belt. Outlet chute with Teflon scrapper for belt cleaning will be provided at the discharge of conveyor. Leg structure made by sq. tube with level adjustment ball fits. Electrical load: 2 hp Make SEW/ Bonfiglioli./ eqvt Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
TWO STAGE VIBRATOR FOR MEMBRANE SEPERATOR for Pomegranate Aril processing Line MOC: Contact parts in S.S.316 & non-contact parts in SS 304. Size-600 mm (w) x 1800 mm (L) Rosta make oscilating mounts - 4 nos. are given for suspension and Italvibra make vibrator motors - 2 nos Collection tray is given at the bottom Connected Load 0.5 H.PX 2 no's. Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
AIR DRYING TUNNEL FOR ARIALS WITH NORMAL AIR COOLING FANS for Pomegranate Aril processing Line M.O.C.: Contact parts in S.S.316 & non-contact parts in SS 304. Size: 600 mm (w) x 3000 mm (L) Tunnel having modular belt to convey the product inside the tunnel. Belt wide long width will help to put down the bars easily. Air drying tunnel effective for normal drying by air fans. Height from ground - 925 mm (estimated)Drying by normal speed air fans- 3 QTY. of Dia. 600 mm with static pressure = 5 mmwc. Tunnel structure having stand on square tube structure with level adjustment ball fits. Height adjustable in to leveling ball fits by +/- 50 mm. Electric Load - 1 H.P. For Belt drive Make SEW/Bonfiglioli/eqvt and Axel fans 1 hp 1400rpm - 3 qty. System having electrical control panel. Panel consist of starters for respective hp of drive motors & V.F.D. for tunnel belt drive only, temperature indicator, emergency stop button. Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
FINAL INSPECTION BELT CONVEYOR for Pomegranate Aril processing Line MOC- SS 304. Size: 300 mm (w) x 5000 mm (l) x 1000 mm ht Channel made from sheet on both side of belt. PVC food grade quality inspection belt. Outlet chute with Teflon scrapper for belt cleaning will be provided at the discharge of conveyor. Leg structure made by sq. tube with level adjustment ball fits. Electrical load: 1 hp Make SEW/ Bonfiglioli./eqvt
ELECTRICAL CONTROL PANEL for Pomegranate Aril processing Line Panel body construct in SS 304. Electrical panel contains V.F.D. for washer elevator & inspection belt conveyor only. Electrical panel contains starter for all other motors with respective H.P., emergency stop button, on/off switch, RYB indicator etc. Related power & control cabling, earthing etc shall be included in the cost. SS cable trays/ conduits shall be used.
Miscellaneous Items : for Pomegranate Aril processing Line Weighing balance with pole display of 0 to 5 Kg. ,acceptable make: Sansui / Eqvt
FRUIT FEEDING BELT CONVEYOR for Pomegranate Juice processing Line MOC- SS 304., Size: 400 mm (w) x 3000 mm (l) x 1000 mm ht, Channel made from sheet on both side of belt with providing 75 mm depth from belt top. PVC food grade quality inspection belt. Outlet chute with Teflon scrapper for belt cleaning shall be provided at the discharge of conveyor. Leg structure made by sq. tube with level adjustment ball fits. Conveyor having feed hopper with minimum possible height to prevent the material spillage during the loading. Electrical load: 1 hp Make SEW/ Bonfiglioli./eqvt approved make Finishing: All parts will be finished to 180 grit Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
FRUIT WASHER for Pomegranate Juice processing Line MOC: SS 304. Size: 700 mm (w) x 3500 mm (L) x 1100 mm (ht). Tank shape to be such that to give easy discharge of water. Necessary inlet and outlet of water with valves and unions shall be provided. Modular perforated belt elevator shall be in built for effective removal of product from the washing tank. Inside the tank, belt having both side S.S. capsule perforated guards to avoide spillage. Capsule size is 6 x 30 mm long with standard triangular pitch. Tank consist of normal water for washing the product. The final spray wash is also provided on the top of the elevator will be RO water washing. Washer have water filtration tank with double screening filtration effect. 1st filtraion sieve hole perforation size will be dia. 3 mm & 2nd will be dia. 1.5 mm hole size. Electrical load: 2 HP & Make SEW / Bonfiglioli, (VFD drive), Pump 3 HP Make Wilo/IPP / eqvt Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
TWO TIER CUTTING BELT CONVEYOR for Pomegranate Juice processing Line MOC: Contact parts in S.S.316 & non-contact parts in SS 304. Size: 600 mm (w) x 5000 mm (L) x 1100 mm (ht).- Bottom belt 300 mm (w) x 5000 mm (L) x 1400 mm (ht) - Top belt Bottom belt carrying the washed fruits and cut head & tail of fruit by manual. Top belt carryig the fruit without head & tail for to feed next marigo belt. Channel made from sheet on both side of belt with providing side cutting pad on both side of conveyor.PVC food grade quality inspection belt. Conveyor both side removable wastage chutes 3 + 3 no's. Conveyor outlet chute with Teflon scrapper for belt cleaning will be provided at the discharge of conveyor. Leg structure made by sq. tube with level adjustment ball fits. Electrical load:1 + 0.5 hp hp Make SEW/ Bonfiglioli/ eqvt Finishing: All parts will be finished to 180 grit. Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
SCREW ELEVATOR FOR PEELER for Pomegranate Juice processing Line MOC: SS 304 SIZE: 300 mm (w) x 4000 mm (Inclined length.) Discharge height suitable to Pulper feeding height. U- Trough in 2.5 mm thickness Screw flights in 3 mm thickness. Supporting structure in square tube. Electrical load: 2 hp make SEW/ Bonfiglioli/ eqvt Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
POMOGRANATE PEELING MACHINE for Pomegranate Juice processing Line M.O.C.: S.S.304. Perforated rotary drum with perforation Dia. 14 mm holes in triangular pitch. Perforated shell construct in 2 mm thickness. Collection tray at bottom which construct in 2 mm thickness. Beaters on shaft Dia. 60 mm with paddles also drive shaft have product pusher screw at feeding hopper. Screw flight construct in 2.5 mm thickness. Electric Load 7.5 H.P Main Drive & 1 H.P of Drum Drive Both are SEW / Bonfiglioli/ eqvt Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
SCREW PRESS for Pomegranate Juice processing Line M.O.C.:Contact parts in S.S.316 & non- contact parts in S.S.304. Size: 850 mm (width) x 2300 mm (Length) Shell made from sq bars mounted on rings Shell Dia. 300 mm id x 700 mm (L) Square tube structure Juice will be collected at bottom. Dry material will come at the other end. Housing in EN8 material with two ball bearings, oil seal, Oil Indicator/cap for oil filling Hopper on top side for loading the material A screw press separates liquids from solids. The screw press squeezes the material against a screen or filter and the liquid is collected through the screen for collection and use. The screw pushes the material at discharge end. An adjustable cone is given at the discharge of the press to adjust the pressure. Electrical load: Drive: 15 HP drive make SEW / Bonfiglioli/eqvt Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
CENTRIFUGAL PUMP 2000 LPH for Pomegranate Juice processing Line Centrifugal type pump SS 316 casing and Impeller. Pump 1 h p. Motor. Kirloskar/ wilo/eqvt
HIGH SPEED CENTRIFUGE for Pomegranate Juice processing Line M.O.C.: All contact parts in S.S.316. Capacity: 500 LPH Centrifuge for seperation of particulate from Pomogranate Juice Pulp. Complete with bowl rotating at 15000 rpm generating centrifugal force of 13,200 times than gravity with bowl holding capacity 6 lit. And dirt holding capacity as 3.5 Lit. Electrical drive: 2 HP Finishing: hygienic with all contact part electro polish.
MIXING TANK 500 LIT for Pomegranate Juice processing Line M.O.C.:Contact parts in S.S.316 & non- contact parts in S.S.304. Size: Dia.1000 mm x 1000 mm ( ht. ) Blending tank with stirrer for effective mixing Shell 2.5 mm thk. with conical bottom. Tank with open top and removable Lid. Tank is supported on four legs with base plate Electrical drive: 1 HP 64 RPM Make SEW/ Bonfiglioli./ eqvt
TUBE IN TUBE PASTURISER for Pomegranate Juice processing Line M.O.C.: All contact parts in S.S.316 & non contact parts in S.S.304. Size: 800 mm (Width) x 3000 mm (Length) x 1000 mm (Height). Tube in tube: 8 Module., Tube in Tube module Dia. 76 mm x Dia. 19 mm - 3 mtr length.2 mm thickness for Outer pipe & 1.6 mm thk. For Inner pipes. Inner & outer tubes are corrugated for creating turbulence in liquid flow inside as well as outside of inner tubes as well as these corrugation will help to increase the surface area of tubes and give better performance. Pipes are Heat treated suitable for Heat exchanger. Temperature programmed: Heating: 35 degree to 95 degree. (Heating media hot water circulation through battery) Heat exchanger for mixing steam & water. Heating media- Hot water circulates through the heating section of the machine to heating the product at set temperature within very fine limits in continuous process. System having flow diversion valve this routes the product after heating section. Automatic precision controls to ensure proper preheat up to certain desired set temperature programme in panel. If the product is properly preheated at desired set temperature, it flows forward through the unit. In case the product is not heated to the set heating temperature, it is automatically diverted by the FDV back to the balance tank. Balance Tank 200 lit capacity. It is usually operated by air pressure. If the temperature of heated product falls below set temperature, air pressure is released and the valve snaps shut immediately. When the temperature is regained, air pressure builds up and the valve opens up for the forward flow to occur. System having two PT-100 temperature sensors - one is at product inlet & 2 nd is near at outlet to show the temperature differences. Centrifugal pump for hot water circulation. Process (screw) pump for product circulation. Inbuilt CIP Pump. All motors are flame proof. Steam regulating valve. All system will be skid mounted. System will be with Pressure gauge & Safety valve.Electric control panel with temperature sensor. Iterconnecting piping in SS of various equipments shall be included in the cost of this item. Acceptable make: Kailash Engg. / Fruit technologies / eqvt apporved
TWO HEAD FILLING MACHINE for Pomegranate Juice processing Line M.O.C.:Complete body will be in SS 304 & Contact parts in S.S.316 Manual Paddle operated machine. Specifications: Capacity : 200 ml to 500 ml Speed: 8 to 10 PPM. Volumetric Accuracy: 0.05 % Pouch: As per your sample; System having insulated hopper. Cylinderical hopper on top of machine- 75 LTR capacity. Hopper construct in material 5 mm thikness. Hopper consist of air vent & temperature sensor. With half fixed & half hinged cover for the hopper. Hopper having high level sensor & interlock with feed pump on/off. (Note - Customer has to be confirm infeed pump HP rating.) With half fixed & half hinged cover for the hopper. Number of nozzle 2 Qty, Nozzle system to avoid the spillage and foaming of product at the time of filling. Filling syringe to achieve accuracy in filling volume and drip proof performance. All Pneumatic fitting will be SMC /FESTO Power supply 440Volt / 50 Hz Cold /hot filling upto 85 Deg Cent. System having manual operated control panel. on/off switch, Push button,relay & Emergency stop switch
COOLING TANK 500 LTR for Pomegranate Juice processing Line M.O.C.: S.S.304. Size: 750 mm (width) x 1250 mm (length) x 800 mm (Height). Tank construct in 2 mm thickness. Rectangular tank with all side round corners. Side glass is provided to view the liquid level in the tank. Tank is provided with Lid. Tank is supported on four legs with level adjustment ball fits.
INK JET PRINTING MACHINE Domino / eqvt approved make for Pomegranate Juice processing Line
ELECTRICAL CONTROL PANEL for Pomegranate Juice processing Line Panel body construct in SS 304. Electrical panel contains V.F.D. for washer elevator & inspection belt conveyor only. Electrical panel contains starter for all other motors with respective H.P., emergency stop button, on/off switch, RYB indicator etc. Related power & control cabling, earthing etc shall be included in the cost. SS cable trays/ conduits shall be used.
Fully imported Semi-Automatic Table Top Tray Sealer: The unit shall be designed in confirming to international standards. Made in Stainless Steel and Mould & Aluminium parts are eloxal coated. All the values to be able to monitored numerically and graphically with the touch operator panel and any action can be done easily. The pneumatic system, gas pressure and vacuum values are controlled by sensors on the machine and operator is directed by warning message on display. Machine reads Vacuum which ensure the best MAP results hence highest shelf lifeconformity. The machine shall provide unlimited mould choice and high performance with the easy to replace mould system. Safety shall be provided as per CE standards. It shallautomatically switche to stop while installing the film or replacing the mould, by the help of security sensors. Installed Power : 220 - 400V 50 Hz, 16 A Energy Consumption : 1.2 Kw Vacuum Pump (upto 20 m3) MAP Production Capacity : upto 2 - 3 cycles/minutes Top Sealing Production Capacity : upto 6 cycles/minutes Air Consumption : 3.6 ltr/cycle Air Pressure : 6 bar Maximum Tray Dimensions : 300 mm X 210 mm Maximum Depth of Plate : 100 mm Maximum Film Width : 350 mm Minimum Film Thickness : 40 micron Maximum Film Roll Weight : 12-14 kg Machine Dimension (L x B x H) : 540 mm x 790 mm x 670 mm Acceptable make:Veripack Semi Automatic Table Top Tray Sealer Machine Model TT05 / eqvt approved Voltage Stabilizer(Energy Consumption, 1.2 Kw) shall be included in the cost of machine. Mould supplied along with machine shall accomodate: 1)100gms, 104mm X 140mm X height 30mm 2)for 250gms, 104mm X 140mm X height 40mm tray. The tray Dimensions are tentative and same shall be confirmed from end user before supplying the equipment.
Hand held Gas Analyser for oxygen / CO2/ N2, battery-operated (rechargeable) for analysis of modified atmospheres in food packages (MAP) with 2 spare needles 2 spare filters, set of 100 rubber seals Witt gas India OXYBABY® M+ / Eqvt approved Make
Vacuum Leak Tester for sealed tray sealing integrity testing Witt gas India Model- Leak-Master EASY / Eqvt approved Make
Gas mixer for 2 gases, (95-90% Nitrogen and 5-10% CO2.) specially designed for Modified Atmosphere Packaging and highly fluctuating gas flows. It shall have infinitely variable mixing and flow settings. constant, accurate mixture when large or very small volumes are needed. independent of pressure fluctuations, packing speed and size of packaging monitoring of the gas supply by pressure switch for operation with sufficient buffer volume. Required piping from cylinders to mixer and mixer to MAP machine along with solenoid valves, isolation valves, pressure control valves etc as per the requirment shall be considered in the costing. Witt gas India model: KM100-2 / Eqvt approved Make
VENTILATION SYSTEM FOR PACKHOUSE & OTHER AREAS Single stage air cooling system as per the general technical specifications For Procesing Hall Supply Air -- Single stage Evaporative cooling unit. SITC of single stage evaporative air cooling units with double skin sheet metal construction 25+/-2 mm thick, CFC free PUF injected (Density 40+/-2 Kg/Cum).The unit shall have DIDW forward/backward curved blowers ,VFD compatible IE2 squirrel cage induction motor, heavy duty GSS base, the evaporative cooling pads minimum 100 mm thick (Munters / Eqvt make) designed for max 150 m/min face velocity, FRP/SS water tank with suitable arrangement for maintaining required water level., water circulating pump with associated UPVC piping, fittings, valves etc , air pre-filters Removable cleanable Al / HDP filter suitable for 90% efficiency upto 20 microns., vibration isolation pads,canvass made of heavy cloth with gaskets to join unit outlet wiht supply air duct, volume control damper etc. Units supplied should be dismantle able type from various sections to suit site conditions & installation. Cap. : 35000 cmh of 15 mm wg.exteranl static pressure.
VENTILATION SYSTEM Exhaust Fans For Processing Hall ,for single stage evaporative air cooling system as per the capacity specified below and complete with (a) Fan with direct coupled motor (b) Mounting ring and brackets (c') Gravity louvers (d) Bird screen Cap. : 11000 cmh of 2.5 mm wg.sp.
VENTILATION SYSTEM - Factory fabricated Air Ducting for ventilation system (round /spiral) with GI sheets as per IS 655 standard duly painted as per the shade required by the architect and insulated with 19 mm EPDM / Nitrile rubber / XLPE insulation , Class O with factory backed aluminium foil applied using suitable self adhesive from the inside of the duct. Duct shall be made of pre-coated /pre-painted color sheets of color as approved by owners/ architects for good asthetic look. All necessary supports, etc to be included in the rate. 20 gauge (1.0 mm)
VENTILATION SYSTEM - Factory fabricated Air Ducting for ventilation system (round /spiral) with GI sheets as per IS 655 standard duly painted as per the shade required by the architect and insulated with 19 mm EPDM / Nitrile rubber / XLPE insulation , Class O with factory backed aluminium foil applied using suitable self adhesive from the inside of the duct. Duct shall be made of pre-coated /pre-painted color sheets of color as approved by owners/ architects for good asthetic look. All necessary supports, etc to be included in the rate. 22 gauge (0.8 mm)
VENTILATION SYSTEM - Factory fabricated Air Ducting for ventilation system (round /spiral) with GI sheets as per IS 655 standard duly painted as per the shade required by the architect and insulated with 19 mm EPDM / Nitrile rubber / XLPE insulation , Class O with factory backed aluminium foil applied using suitable self adhesive from the inside of the duct. Duct shall be made of pre-coated /pre-painted color sheets of color as approved by owners/ architects for good asthetic look. All necessary supports, etc to be included in the rate. 24 gauge (0.63 mm)
VENTILATION SYSTEM - Supply and installation of supply air linear grills in aluminium powder coated construction with with shade as required by architect along with matt finish aluminium dampers for sizes as may be required.
Workers Toilet ventilation: SITC of Centrifugal type fan with cabinet suitable for location on exposed wall with forward / backward curved blades and DIDW construction. The capacity shall be as mentioned below. The fan shall be suitable for static pressure of 12 mm.Mounting bracket. stand as may be required shall be incuded in the costing. cost for electrical supply from avaible nearest point shall also be included. For Toilets: 2500 cmh (1470 cfm) :
Workers Toilet ventilation:Supply, erection and testing of air ducting made out of GS sheet of Grade 120 as per latest IS 277 (120 gsm) or higher complete with neoprene gaskets, branch dampers, guide vanes and supports as per standard practice. All ducting joints shall be flange type joints only for exhaust ducting regardless of the size of the duct.
22 Gauge (0.8 mm)
24 Gauge (0.63 mm)
Workers Toilet ventilation:Supply and erection of Exhaust air Grilles in Aluminium construction and with powder coated finish of various sizes to the satisfaction of the owners and architects :
VENTILATION SYSTEM - Toilets - Exhaust Fans - approx 230 mm dia as per the capacity specified below and complete with (a) Fan with direct coupled motor (b) Mounting ring and brackets (c) Gravity louvers (d) Bird screen Necessary electrical cabling etc shall be included in the cost.
VENTILATION SYSTEM - Exhaust Fans- Packing Material Store & crate storage as per the capacity specified below and complete with (a) Fan with direct coupled motor (b) Mounting ring and brackets (c) Gravity louvers (d) Bird screen Cap. : 4500 cmh Necessary electrical cabling etc shall be included in the cost.
PART III - VENTILATION SYSTEM - Air Curtains for Cold Storage-1 to 7 & Pre-cooling 1,2,3 Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: 1500mm X 2600mm ht
Air Curtains for Blast Freezer & Frozen Chamber, Processing area to ante room CS and Ante room to dispatch dock, Pre-cooling & cold room for Arils Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: 1500mm X 2100mm ht
Air Curtains for entry to mango processing area & exit to ante-room, Packing material store & dry Storage Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: 2000mm X 2100mm ht
Air Curtains for ante-room to outside- emergency exit door, main office lobby to dispatch dock and dispatch/ receiving dock to dock office, emergency exit towards aril, LAb, PQ area Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: 1000mm X 2000mm ht
VENTILATION SYSTEM - Air Curtains for receiving to holding, holding to process area, holding to Aril, process area to aril,aril to aril Ante-room Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: 2200mm X 2200mm ht
VENTILATION SYSTEM - Air Curtains for changing room doors Supply & fixing of industrial type air curtains suitable for door clear opening size as mentioned and specifications given below. The Air Curtains shall incorporate centrifugal blowers made of SS / Aluminium with sealed ball bearings. The blowers shall be statistically and dynamically balanced. The motor shall be of standard make suitable for operation on single phase or three phase AC supply. The casing shall have a sturdy construction in SS304 finish. Adjustable louvers shall be provided for streamlining the air delivery.Air velocity to be in the range of 12 to 15 m/s. Proximity sensor with controller switch (limit switch) to be provided to ensure that the air curtain operates only when the door is open. Necessary fixing arrangement including sturdy brackets or base frame to bring the air curtain to the required level for proper air flow shall also be included in the cost. Necessary cabling in casing-capping / conduits as required by architects/owners from the switch points provided near the door shall also be included in the costing. Suitable for Clear opening size: 850mm X 2100mm ht
HVAC SYSTEM FOR OFFICE: Supplying, erecting, testing and commissioning 20 HP, VRF / VRV air conditioning system, outdoor unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and nonstop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete Cooling Capacity 52.75kW [15 TR] minimum
Supply,installation,testing and commissioning of following minimum capacity 4-wayflow VRV/VRF CassetteType Indoor ceiling mounted unit
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 2.0TR ( 618 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominalcooling capacity 1.5TR ( 512 cfm) having EER as per BEE standards and specifications,suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominalcooling capacity 1.0TR ( 441 cfm) having EER as per BEE standards and specifications,suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply air fan: Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline fresh air fan inlet unit having 1000 cfm capacity with maintaining the static pressure minimum 20 mm of Hg complete suitable to operate on 1ph, 230 V, 50Hz, A.C. supply.
SITC of Automatic Duct Flow Controllers (Aldes or equivalent) for supply of controlled air flow as per individual fresh air requirement of the indoor units.
Supplying and erecting an air flow regulating valves / dampers in provided flexible or rigid duct / pipe of 100 mm size with an alteration for existing flexible pvc pipe duct and necessary joints, sealing, couplings complete at position.
Supplying and erecting an air flow regulating valves / dampers in provided flexible or rigid duct / pipe of 80 mm size with an alteration for existing flexible pvc pipe duct and necessary joints, sealing, couplings complete at position.
Supplying and erecting an air flow regulating valves / dampers in provided flexible or rigid duct / pipe of 50 mm size with an alteration for existing flexible pvc pipe duct and necessary joints, sealing, couplings complete at position
SITC of hard PVC pipe for fresh air connection to indoor unit including elbow, bends, coupler etc There shall be insulation on the piping as required to ensure that there will be no condensation on the pipes under any circumstances. Piping shall include elbows, removable and cleanable type air filter and supports from wall / ceiling. The piping shall be insulated with 6mm thick EPDM / Nitrile foam insulation with factory backed Aluminium foil.Bird screen with insect traps to be included. Dia 300 mm
SITC of hard PVC pipe for fresh air connection to indoor unit including elbow, bends, coupler etc There shall be insulation on the piping as required to ensure that there will be no condensation on the pipes under any circumstances. Piping shall include elbows, removable and cleanable type air filter and supports from wall / ceiling. The piping shall be insulated with 6mm thick EPDM / Nitrile foam insulation with factory backed Aluminium foil.Bird screen with insect traps to be included. Dia 200 mm
SITC of hard PVC pipe for fresh air connection to indoor unit including elbow, bends, coupler etc There shall be insulation on the piping as required to ensure that there will be no condensation on the pipes under any circumstances. Piping shall include elbows, removable and cleanable type air filter and supports from wall / ceiling. The piping shall be insulated with 6mm thick EPDM / Nitrile foam insulation with factory backed Aluminium foil.Bird screen with insect traps to be included. Dia 100 mm
Copper piping between Outdoor and Indoor Units FOR HVAC SYSTEM FOR OFFICE
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 41.3 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 34.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages,fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV /VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of,appropriate nominal refrigerant copper pipe of 19.1 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of,appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of,appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of,appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of,appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system
Preinsulated flexible duct for indoor connection-100 mm Dia The last 1m should be preinsulated flexible round ducting of 100mm dia or as per the indoor unit fresh air opening size.
SITC of Drain Piping using heavy duty PVC pipe with 6 mm EPDM / Nitrile foam insulation. The drain shall be led to the nearest toilet or drain point as specified by the department.
Treatment of Exposed Piping with Woven Glass Cloth 125 gsm finished in U/V Treated, pigmented Epoxy for Outdoor Piping, as per relevant code. This may also be done with weather proof coating like Armacheck GC/Eqvt
SITC of control panel FOR HVAC System for office building - The panel shall be floor mounted, totally enclosed compartmentalized, cubicle with rigid construction made from 16 gauge thick MS sheet and stiffened with angle iron frame work. The control panel shall consist of bus bar chambers main incoming and outgoing MCBs for the condensing unit motors etc as may be required and their respective starters, voltmeter, ammeter, indicating lamps, interlocking arrangement, rubber mats, hooter for alarm, etc complete as required. Cenrtalised controller with necessary power & control wiring for common operation with functionality of controlling ON/OFF and temperature setting of all cassette units from single location shall be part of electrical control panel. Electrical control cabling to ensure fully automatic operation and communication between indoor and outdoor units shall be included Incomer cabling including terminations on both sides from main facility MCC to the VRV / VRF system panel with armoured Aluminium cabling shall also be included in the cost
6/16 points for indoor unit power including cabling from electrical panel
Communication cable of between Indoor Unit and Outdoor unit with PVC conduit. Size: Copper Shielded cable - 0.75 Sq.mm X 2 Core
Minor Civil works such as breaking of existing brick wall for holes in walls for refrigerant / drain piping or cable entries, ducting, fresh air fan etc as required and making good including paiting to the satisfaction of the Engineer in-charge.
Commissioning and additional charge of Gas and compressor Oil as required upto commissioning and handing over FOR HVAC System for office building
Miscellaneous Items : For Control Room (1 working + 1 stand by), Lab Supplying, installing, testing and commissioning split type variable speed inverter technology room Airconditioning unit 1 TR having ISEER minimum 4.50 suitable to operate on capacity 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall / floor mounting type complete with refrigerant R410A/R32 and copper condenser at position. specification no. APAC/SAC
Miscellaneous Items : For Dock Office, PQ area Supplying, installing, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity having ISEER minimum 4.50 suitable to operate on250V, 50 cycles, A.C. supply having 1 no of air handling unit hiwall / floor mounting type complete with refrigerant R410 A/R32 and copper condensor at position. specification no.APAC/ SAC
SITC of Centrifugal type fan with cabinet suitable for location on exposed terrace with forward / backward curved blades and DIDW construction. The capacity shall be as mentioned below. The fan shall be suitable for static pressure of 12 mm For Toilets: 2000 cmh (1180 cfm) :
Supply, erection and testing of air ducting made out of GS sheet of Grade 120 as per latest IS 277 (120 gsm) or higher complete with neoprene gaskets, branch dampers, guide vanes and supports as per standard practice. All ducting joints shall be flange type joints only for exhaust ducting regardless of the size of the duct. 22 Gauge (0.8 mm)
Supply, erection and testing of air ducting made out of GS sheet of Grade 120 as per latest IS 277 (120 gsm) or higher complete with neoprene gaskets, branch dampers, guide vanes and supports as per standard practice. All ducting joints shall be flange type joints only for exhaust ducting regardless of the size of the duct. 24 Gauge (0.63 mm)
Supply and erection of Exhaust air Grilles in Aluminium construction and with powder coated finish of various sizes to the satisfaction of the owners and architects for HVAC system for office building
Supply, install, testing & commissioning IP IR 2MP Dome Camera :(CCTV works) - with 1080p Full HD Resolution @25/30fps - with 1/2.8" CMOS Image sensor, - IR with range of 40 m or more for better night vision - Varifocal lens ranges from min 2.7mm– max 13.5mm - Minimum 120dB WDR - Should have Dynamic Noise Reduction to optimise the recording space - IP67 or better weatherproof rating for camera to working in harsh envoirment - Ik10 or better vandalproof rating - Min. Illumination : 0.002 Lux - Operating temperature range -30°C to +60°C - Humidity Up to ≤95% - Video Compression : H.265; H.264; H.264B; MJPEG - Should have white balance in Auto/natural/street lamp/outdoor/manual/regional custom - Should have min 4 areas region of interest - Electronic Shutter Speed : Auto/Manual 1/3 s–1/100000 s - Should have motion detection, Video tempering, network disconnected - Should have dual stream (Main and Sub) - Onboard Memory card slot supporting min 256GB or more for recording at cameras itself. - Should have capability of motion detection, Video tampering, - Electronic Shutter Speed : 1/30s to 1/15000s - Automatic network replenishment feature should be available for seamless recording even in the event of loss of network. - Interoperability of ONVIF Profile S & G Acceptable makes: Bosch/Samsung/ Honeywell/ Dahua / eqvt approved Mounting accessories like saddles, glands(Single compression), nuts-bolts, tags, screws, binding wires etc shall be included in the costing.
Supply, install, testing & commissioning of IP IR 2MP Outdoor Bullet Camera :(CCTV works) - with 1080p Full HD Resolution @25/30fps - with 1/2.8" CMOS Image sensor, - IR with range of 50 m or more for better night vision - Varifocal lens ranges from min 2.7mm– max 13.5mm - Minimum 120dB WDR - Should have Dynamic Noise Reduction to optimise the recording space - IP67 or better weatherproof rating for camera to working in harsh envoirment - Min. Illumination : 0.002 Lux - Operating temperature range -30°C to +60°C - Humidity Up to ≤95% - Video Compression : H.265; H.264; H.264B; MJPEG - Should have white balance in Auto/natural/street lamp/outdoor/manual/regional custom - Should have min 4 areas region of interest - Electronic Shutter Speed : Auto/Manual 1/3 s–1/100000 s - Should have motion detection, Video tempering, network disconnected - Should have dual stream (Main and Sub) - Onboard Memory card slot supporting min 256GB or more for recording at cameras itself. - Should have capability of motion detection, Video tampering, - Electronic Shutter Speed : 1/30s to 1/15000s - Automatic network replenishment feature should be available for seamless recording even in the event of loss of network. - Interoperability of ONVIF Profile S & G - CE, UL, FCC Certified, Acceptable makes: Bosch/Samsung/ Honeywell/ Dahua / eqvt approved Mounting accessories like saddles, glands(Single compression), nuts-bolts, tags, screws, binding wires etc shall be included in the costing.
Supply, install, testing & commissioning 32 ch NVR with storage:(CCTV works) 32 Channel Network video recorder loaded with preloaded channel licences and 8TB HDD used for live viewing and playback, should have quad core processor, linux operating system, Should be CE, UL Certified. Recording of Camera as per below settings : - Recording resolution= 720p, - Recording frame Rate= 15fps, - Retention period= 15days. Acceptable makes: Bosch/Samsung/ Honeywell/ eqvt approved
Supply, install, testing & commissioning 42" monitor with HDMI Cable acceptable makes: Samsung/LG/Dell/eqvt
Supply, install, testing & commissioning 8 Ports POE Switch with 2 SFP ports for cameras (CCTV works)
Supply, install, testing & commissioning SFP module SM (CCTV works)
Supply, install, testing & commissioning Loaded LIU (CCTV works)
Supply, install, testing & commissioning of OFC Patch cord (CCTV works)
Supply, install, testing & commissioning Industrial Media Converter (CCTV works)
Supply, install, testing & commissioning 15U Server Rack With Fans and Spike Gurard Power Sockets, cable Manager and required accessories (CCTV works)
Supply, install, testing & commissioning 6U Wall mount Rack With Fans and Spike Gurard Power Sockets, cable Manager and required accessories (CCTV works)
Supply, install, testing & commissioning 12 Port LIU, Rack Mounted, Fully loaded, Single Mode (CCTV works)
Supply, install, testing & commissioning of Cat 6 Cable (CCTV works)
Supply, install, testing & commissioning of PVC conduit of size 25 mm (CCTV works)
Supply, install, testing & commissioning of FO Cable,6 Core SM,Armoured (CCTV works)
SITC of Standalone Access Card+Pin based reader cum controller :(Access Control System) CPU : 32 Bit RISC Arm Processor Memory : Upto Flash 8 MB Event/transaction : Upto 99,999 No.of Users : Upto 39,999 Operation Mode : Card Only, Card + Pin (On Weigand Card Only) Inbuilt Card Reader Supports : HID iClass Security, HID Prox, EM Cards, Mifare Communication Port : TCP/IP, Wiegand Controller ID : Upto 9,999 LCD Display : 128 x 64 Bicolor COG LCD Keypad : Touchscreen Keypad LED : Tricolor Input/Output : 3(Door status, Egress, Fire)/3(DOTL, Lock,Alarm) Security Feature : Anti-passback, Facility Establishment Code, Time Zone, Duress Card/Fingure for enhancesed security Contry of Origine : India Acceptable make: HID/Honeywell/Smart-i / eqvt approved
SITC of Power Supply for Reader cum Controller Acceptable make: HID/Honeywell/Smart-i / eqvt approved (Access Control System)
Access Cards: Contactless Smart Card, shall operate on 125 kHz , Acceptable make: HID/Honeywell/eqvt approved (Access Control System)
Supply, Installation,Testing & Commissioning of Push button/Request to Exit Switch, acceptable makes: Algtec/BEL/eqvt approved (Access Control System)
Electro Magnetic Lock : 600 lbs, with LED, with required accessories (for single leaf door) (Note : Type of EM lock to be supplied according to the door type and must be confirmed with Consultant/User prior to supply of material) acceptable makes: Algtec/BEL/eqvt approved
Door Position Sensor (DPS ) for door information feed back, acceptable makes: SECMS4/Algatec/ eqvt approved (Access Control System)
Power Supply for Electro Magnetic Lock . (Access Control System)
Cable : 2 Core x 0.5 sq mm, 22AWG, copper, shielded, Un-Armoured Cable (between controller and Exit switch, Magnetic Contact) acceptable makes:Polycab/Finolex/ eqvt approved (Access Control System)
Cable : 2 Core x 0.5 sq mm, 16AWG, copper, shielded, Un-Armoured Cable (between controller and EM LOck), acceptable makes:Polycab/Finolex/ eqvt approved (Access Control System)
Supply,Installation,Testing & Commissioning of Network Controller (PA System) SITC of EN-54 Certified EVAC PA controller with minimum 12 zones in the system and expandable upto 400 zones with 14x 4 Audio matrix with full DSP functionality. 8 audio inputs, 4 audio outputs, 4 channel output matrix. Shall support the following: single line switching or redundant group A/B switching, amplifier redundany, 4 x 100V audio inputs and 12 speaker line outputs. 8000 fault, warning and event conditions log. Built in message manager for 100 emergency/business calls up to 85 minutes. 10 control inputs and 13 control outputs. Impedance measurement and Pilot Tone supervision for speaker line monitoring. Frequency response (ref. 1 kHz) 20 Hz to 20 kHz (-0.5 dB), Signal-to-noise ratio (A-weighted): Line in to line out: 106 dB typical, THD+N < 0.05%, Crosstalk (line level) Line in to line out (0 dB gain): < 100 dB at 1 kHz, Sample rate 48 kHz, DSP processing resolution 24-bit linear A/D and D/A conversion, 48-bit processing. Should be provided with a Configuration and Graphics User Interface Software.Mounting accessories like saddles, glands(Single compression), nuts-bolts, tags, screws, binding wires etc shall be included in the cost. Acceptable makes: Audio Technica/Bosch/LDA/TOA/Bose/eqvt approved
Supply,Installation,Testing & Commissioning of 480W Amplifier (PA System) Supply ,installation and testing of 480 W power amplifier in a 3U high housing with 70 V / 100 V and 8 ohm outputs,Dual inputs with priority switching,100 V input for slave operation on 100 V speaker line,Mains, battery back-up, With Following Features: 1.Output power (rms/maximum) 480 W / 720 W 2.Frequency response 60 Hz to 18 kHz (+1 / -3 dB at -10 dB ref. rated output) 3.Distortion <1% @ rated output power, 1 kHz 4.S/N (flat at max volume) >90 dB 5.Battery power supply:24 VDC +15% / -15% Acceptable makes: Audio Technica/Bosch/LDA/TOA/Bose/eqvt approved Mounting accessories like saddles, glands(Single compression), nuts-bolts, tags, screws, binding wires etc shall be included in the cost.
Supply,Installation,Testing & Commissioning of 6w Ceiling Speaker with back box 6W ceiling mount speaker with excellent speech & music reproduction (PA System) - Max Power: 9W,Rated Power: 6Watts, Power Tapping: 6/3/1.5W - Effective frequency range(-10 dB) : 150 Hz to 15KHz - SPL at rated power (1Khz at 1 m) 108 dB - Opening Angle 1 KHz / 4 KHz:: 180° / 45° Acceptable makes: Audio Technica/Bosch/LDA/TOA/Bose/eqvt approved Mounting accessories like saddles, glands(Single compression), nuts-bolts, tags, screws, binding wires etc shall be included in the cost.
Supply,Installation,Testing & Commissioning of 6w Cabinet Speaker (PA System) - 6W wall mount speaker with excellent speech & music reproduction - Max Power: 9W,Rated Power: 6Watts, Power Tapping: 6/3/1.5W - Effective frequency range(-10 dB) : 200 Hz to 15KHz - SPL at rated power (1Khz at 1 m) 96 dB - Opening Angle 1 KHz / 4 KHz (-6 dB): 150/70 Acceptable makes: Audio Technica/Bosch/LDA/TOA/Bose/eqvt approved Mounting accessories like saddles, glands(Single compression), nuts-bolts, tags, screws, binding wires etc shall be included in the cost.
Supply,Installation,Testing & Commissioning of 15w Elliptical horn Speaker (PA System) - 15W Horn speaker with excellent speech reproduction - Max Power: 22.5 W,Rated Power: 15 Watts - Effective frequency range(-10 dB) :500 Hz to 3500 Hz - SPL at 1W power (1Khz at 1 m) 103 dB - Opening Angle 1 KHz / 4 KHz (-6 dB):110 (H) / 50 (V) -IP rating:- IP 65. Acceptable makes: Audio Technica/Bosch/LDA/TOA/Bose/eqvt approved Mounting accessories like saddles, glands(Single compression), nuts-bolts, tags, screws, binding wires etc shall be included in the cost.
Supply,installation of 2C X 1.5sq.mm cable, Armoured cable (PA System)
Supply of Cat-6 Cable (PA System)
Supply of 15U Network Rack (PA System)
On Grid Roof Top Solar Power Plant under for Design, Engineering, Procurement, Installation, Testing and Commissioning. This also includes necessary permissions from Electrical inspector & MSEDCL / Any other statutory body for NET metering. Solar plant shall be designed with Mono / Polycrystalline PV Modules with String or Micro Inverters. Bidder shall propose any New technology which will enhance energy generation from the plant. Weather station showing real-time weather conditions / parameters shall be part of this installation. Cloud based real-time Power Plant performance monitoring system with fault alarms shall be part of this contract. This Data shall be accessible on PCs / Smart Phones and to any number of persons as owner may desire.Training of end user staff to manage day to day operation shall be given. Load evacuation : 415V, 3 Phase AC, 50 Hz A standalone solar photovoltaic power generator/plant proposed comprises of solar PV modules of given capacity, with battery bank, PCU with necessary control, electronics, panels, interconnecting AC heavy duty armoured cables, DC cables (TUV approved) ,cable trays, module mounting structures to get maximum output in Al/ hot dip galvanised structure, necessary grounding /earthing, earthing pits, complete earthing system & lightning protection system, arragement for access to panels for maintenance considering safety ascpect etc. Bidder’s scope shall also include to store and maintain, handle the equipment / material, including the cleaning and upkeep of the rooftop solar PV modules for a duration of Five (05) years. Free maintenance will be for 2 years. The maintenance will be on comprehensive basis, inclusive of all components & ancillaries etc. Accetpable makes for PV modules: Vikram Solar / Tata Solar / Navitas / Eqvt Approved Tier-I supplier Acceptable makes for inverter: SMA / Fronius / Delta / Kaco / ABB / Eqvt approved Acceptable make for DC cables : Lapp / TOP / Polycab / RR / Eqvt approved
Pallets Dimensions: 1000mm X 1200mm X 150 mm approx. ht Colour: as approved by client Pallet type: four side fork opening Weight carrying capacity: 1500 Kg Suitable to use with all kind of material handling equipments including hand pallet trucks etc. Working Temperature range: (-) 25 deg C to (+) 10 deg C heavy duty type, Top Deck : Perforated MOC Shall be food grade plastic/HDPE and shall have excellent impact strength and high compression resistance. Acceptable makes: Nilkamal/Supreme / Eqvt
Miscellaneous Items : PVC Crates suitables for handling fresh fruits Nikamal make Model - JBC 64160 or eqvt.
Miscellaneous Items : Weighing balance in SS construction of 150 Kg. each digital type, Sansui model no:SPP SS 150 / Eqvt
Miscellaneous Items : Carton Strapping Machine Semi Automatic 800 mm max. size of product may be considered. Make model : Novastrap-Pack NP-306 / Robertseal Corp. EXS-306 / Eqvt
Miscellaneous Items : Insect Killer, “Russell” ‘Carolyn’ Glue Board Insect Killer/ Eqvt, Stainless Steel Body 304 with stainless steel screws and stainless steel grills with glue board, suitable mounting arrangment. Confirming to CGMP & food safety standards.
Hydraulically Operated Hand Pallet Truck Type : Hydraulically operated Hand Pallet Truck Manufacturer : Godrej / Toyota / Linde / Jungheinrich / Nilkamal / Josts / Eqvt. Model No. : to be mentioned Load Capacity in kgs: 1500 kg Fork Length in mm (Suitable for liifting pallet of size of 1000 mm X1200 mm X154 mm ) Wheel MOC : Nylon / Polyurethane Suitable for heavy duty operation and long life,
Battery Operated Hand Pallet Truck Type : Hydraulically operated Hand Pallet Truck Manufacturer : Godrej / Toyota / Linde / Jungheinrich / Nilkamal / Josts / Eqvt. Model No. : Godrej Edge GPPT -1500 Load Capacity in kgs: 1500 kg Fork Length in mm (Suitable for liifting pallet of size of 1000 mm X1200 mm X154 mm ) Wheel MOC : Nylon / Polyurethane battery: Lithium ion battery with charger included Suitable for heavy duty operation and long life
Miscellaneous Items : Weigh bridge suitable for 60 MT capacity complete as per following specification. Make: Standard Indian / Imported. Please indicated the make Type: Electronic load cell based, pitless. Capacity: 60 MT. Least count: 5 Kgs. ,Platform size: 16 M x 3 M. approx. Material of construction of platform: Mild steel structure finished with one coat of Red Oxide primer and Black enamel finish. Top deck : MS Plate with adequate section suitably ribbed to avoid skidding. Load sensors and type of Strain Guage: “P.T.” double-ended shear beam load cell. Foil type strain gauges. Bridge resistance: 700 OHMS. (Nominal). No. of load cells: 16 Nos or as recommended by manufacturer Safe over load capacity: 150 % of rated capacity. Ultimate over load capacity: 300 % of rated capacity. Display: Digital. Resolution: Same as least count. Tare facility: Push button. Weighing method: Static. Calibration: Auto – Calibration facility. Computer interface: In – built RS 232 C Port facility. Power supply required: 230 V, 50 Hz, Single phase. Operating temperature: 10 Deg. C. to 55 Degree C. System Accuracy : +/- 0.05% full scale or as per IS 9821 specification (Part I to IV) The work shall include supply, Installation , Testing and Commissioning of the weigh bridge PC with 19 inch monitor , UPS and printer also shall be supplied and costing for the same also shall be considered.
SITC of RO water plant of capacity 5000 lph complete with raw water pump CRI/kirloskar/ eqvt, sand filter, carbon filter, anti-scaling dosing system, micron cartridge filter (5 micron) ss316 construction, high pressure pump in SS construction, RO product water storge tank, raw water storage TANK, Membranes (imported), solenoid valves, auto flushing system, designed noise less fittings, dosing pump & tank inside cabinet, control panel fro operation, power control cabling, earthing, multi port valve, back wash & service mode MPV, float switch for tank operation, sturdy skid frame in SS construction etc. as may be required. Acceptable make: Thermax/ Eqvt Approoved
Supplying, erecting, testing and commissioning selfcontained water cooler 230/250 V 50 cycles nominal cooling capacity of 80 litres/hr and storage capacity 120 litres with partially stainless steel body complete. specification no. AP-WCR/WCAcceptable make: Blusetar model SDLx8012B / eqvt approved make
Temperature & Relative humidity Environmental Test chamber
Miscellaneous Items : Lab Equipments: Acceptable make: Borosil /eqvt approved pipette- 5ml : 5 nos, pipette- 1ml: 10 nos, Beaker (glass)- 50 ml: 4 nos, Beaker (glass)- 100 ml: 4 nos, Beaker (glass)- 250 ml: 4 nos, Beaker (glass)- 500 ml: 4 nos, beaker (plastic)- 100ml: 4 nos, beaker (plastic)- 1000ml: 4 nos, conical flask- 100 ml: 6 nos, conical flask- 250 ml: 6 nos, M.cylinder (A-class)- 100ml: 2 nos, M.cylinder (B-class)- 250ml: 4 nos, M.cylinder (B-class)- 500ml: 2 nos, M.cylinder (B-class)- 1000ml: 2 nos, vol flask- 100ml: 3 nos, vol flask- 250ml: 3 nos, test tube stand: 4 nos, test tube stand: 4 nos, Durhams tube: 1 no, Mortan and pestle: 1 no, Burret stand with M.S road,clamp with boss head: 1 no, micropipette fully autoclavable (100-100UL): 2 nos, s.s spatulla 8'' : 4 nos,Burette with screw type 50ml: 1 no, Micro Tips(100UL) 100UL: 2 nos, test tube 18*150mm: 100, funnel long stem 100mm: 4 nos, strring rid glass 8'': 5 nos, nichrome loop 50ml: 3 nos, Reagent bottle amber color with screw cap 50ml: 2 nos, Reagent bottle amber color with screw cap 100ml: 2 nos, Reagent bottle amber color with screw cap 250ml: 2 nos, Reagent bottle amber color with screw cap 500ml: 5 nos, Reagent bottle amber color with screw cap 1000ml: 2 nos, Wash bottle 500ml: 2 nos, Pvc M.cylinder 10ml: 2 nos, Pvc M.cylinder with hexagonal base 100ml: 2 nos Pvc M.cylinder 1000ml: 5 nos test tube brush: 5 nos, forcep hevy 6": 2 nos, forcep hevy 8": 2 nos, Burette 50ml 50ml: 2 nos, Burette stand: 2 nos, Pipette 2 ml : 2 nos, Pipette 5 ml 5ml: 3 nos
Horizontal laminar air flow, MOC- Outer MS Powder Coated & Inner SS , size: 1200*600*600, 1 kW, LABLINC / eqvt approved make
Autoclave , MOC- Inner & outer SS body , size: 450*600, 4kW (95 Lts), LABLINC / eqvt approved make
Oven Universal - 18" x 18" x 24 " ( Digital /Fan ),MOC-Outer MS powder coated & inner SS, size: 455*457*610, 2kW, :LABLINC / eqvt approved make
BUD incubator- 4 CFT ,112 LTS,Digital,MOC- Outer MS Powder coated & Innner SS, size: 455*455*455, 4 kW, :LABLINC / eqvt approved make
Bacteriological incubator (memmert type), Size- 18" x 18" x 24 ", MOC-Outer MS powder coated & inner SS, size: 457*457*609, 750 watts, LABLINC / eqvt approved make
Binocular research microscope, size: 17*13*9.5, LABLINC / eqvt approved make
Colony counter Digital, size: 279*254*241, 1000 watts, LABLINC / eqvt approved make
Weighing Balance (0.001 mg to200gm), LABLINC / eqvt approved make
Magnetic stirrer with hot plate, size: 279*203*152, watts, LABLINC / eqvt approved make
Serological Water Bath - Digital, MOC, 381*305*254, 1kW, LABLINC / eqvt approved make
Vernier caliper DIGITAL 150MM, Electronics india / eqvt approved make
Weighing balance 20 kg ,least count: 1gm, Electronics india / eqvt approved make
Weighing balance- 0.001 to 200 gm(REGULAR QUALITY), Electronics india / eqvt approved make
pH meter DIGITAL, Labtronics / eqvt make
TSS meter(Refractometer) Range 0 to 32°, Erma / eqvt make
Rubber cork
Digital hand held TDS meter 0-3000, HM Taiwan / eqvt approved make
Digital multystem Thermometer (pen type) -50 to 300 degree C
Flexible Arm Illuminated Magnifier Lens: Specially designed, distortion controlled high quality lens correctly sized for both eyed (bi-ocular) vision. Lens Size: 170mm x105 mm, with power 3.2D. Provides about 4 times area magnification. Working clearance below lens mount is 250 mm, and field seen can be up to 250 mm. Illumination: 2 x7 watt standard CFLs with independent switches that enable shadow free or directional bright illumination in the work area. Stand: Highly optimized design , spring balance stand with feather-touch movement to place lens in the correct position and orientation. Lens center can reach out 900 mm in front of mount axis with up to 360 degrees swivel Model: Lensel Flexible Arm Illuminated Magnifier Deluxe Model with Movable Base (L104DX+L104B) / Eqvt
Lab Equipments of reputed makes a) Temprature Probes to measure temprature of the fruit - 6 nos b) Refractometer to check the total soluble solids - 2 no. c) Differntial Colour Charts to Check Colour of the fruit - 4 no. d) Penetrometer to measure Pulp pressure - 3 no. e) other related equipments as may be required
Worker Bench with SS304 Top and Structure of MS Sq.pipe. Suitable for 4 persons 400 X 2400 X 400mm
Locker Cabinet -24 Lockers of 300x300mm approx. size:1875mm X1200mmX 400mm
Shoe Rack with 8 shelves and closed Back approx. size:1500mm X1200mmX 300mm
Apron Hanger Stand made of SQ Pipe with Castor wheels and one Oval Rod for hangers approx. size:1500mm X1000mmX 600mm
Twin Sink Hand Wash Unit in SS304, completely enclosed from all sides with front hinged doors. With Tap and Drain Pipe
M7.5-1D+2S (1Drawer+2Shelf Unit) approx size: 900 X 750 X 750 mm
M6-1D+2S (1Drawer+2Shelf Unit) approx size: 900 X 600 X 750 mm
CU-810x810 (Corner Unit with SS304 Sink) approx size: 900 X 810 X 750 mm
Z Black, 18 Thick Granite Top
Filing Cabinet with front hinged door and separator for keeping Box Files/Office Files in upright position. approx size: 1800 X 600 X 500 mm
Office Table with 1 no Side Shelving Unit and 1 no. Drawer Pedestal. With MS Top. Without Chairs. approx size: 780 X 1200 X 600 mm
M9- (Sink Unit with SS304 Sink) approx size: 900 X 900 X 750 mm
M7.5-1D+2S (1Drawer+2Shelf Unit) approx size: 900 X 750 X 750 mm
M5-1D+2S (1Drawer+2Shelf Unit) approx size: 900 X 500 X 750 mm
Computer Table with keyboard drawer approx size: 900 X 750 X 750 mm
Stainless Steel Stools: Design Type: Standard, Diameter: 300 mm, Height: 800 mm, Material: Stainless Steel
Disposable Face Masks suitabe for use in Food Packaging Industry, - Color of Face Mask: White /Blue/Green - Bacterial Filtration Efficiency: 99.7% - Outer Layer: 25 gms
Disposable Stretchable White Caps, Cover Hair for hygiene
Cotton Plain Industrial Aprons, material: cotton, pattern: plain
PE Food Grade Disposable Gloves,full finger coverage, size: 6 inch
Pair of Safety leather shoes of various sizes as approved by end user suitable for use in food industry. Bata / eqvt approved make
Lab coat white color in various sizes as approved by end user
LED dock light to illuminate the full length of truck trailers. Standards:CE Dimensions lamp (LxWxH): 88x133x171 mm Dimensions with swing arm (LxWxH): 1120x133x314 mm Life span: 50.000 hours Power consumption: 16W Number of LEDs: 11 Power connection:220 V AC Connection lamp:C13 connector Protection class:IP65 Acceptable make: Metaflex model: ADL-LED220-SET /eqvt
Supply,fabrication, fixing of bollards, panel protection gaurds, wheel gurads complete with baseplate & its fixing (if required) in MS pipe of various diameters as per requirement and design as approved by consultants.including two coats of synsthetic enamel paint inclusive of red oxide primer coat.
Providing fabricationg and erecting in position Structural Steel (channels, angles etc), for insulated roof/wall panel supports, primary supports at roof level for ACUs etc. as per approved drawings and specifications and instructions including straightning, cutting, drilling, bending, welding, reveting, bolting, splicing and provising and casting in position foundation bolts etc. as may be required and including three coats of synsthetic enamel paint inclusive of red oxide primer coat.
SITC of Electric Traction Passenger Lift with Rated capacity :- 8 Passenger/544Kg Floors :- G+1 floor (2Stops/2 Landings) Travel :- 3 to 4.2 mtrs Location of Lift Machine:- MR/MRL as per site conditions Rated speed :- 1.0mps VS Doors type :- 800mm wide x 2000mm high clear entrance having 1.5mm thick SS 304 grade sheet car door [Two panel] complete with required accessories like door operator mechanism with drive, required Aluminium sill, infrared curtain & necessary wiring with interlocking arrangement etc. complete. Hairline finish for car and all landing doors with SS door architraves/frames Lift car enclosure made from SS 304 grade sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. COP with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with/without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor Clear Car size of 1200 mm wide x 1100mm deep x 2200mm inside ht LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port, control panel duly wired with proper size & strength copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class ARD complete with necessary SMF VRLA batteries Fireman controller having fireman switch at fire Landing,
CCTV surveillance system comprises of 2nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for 60 days with 18" FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. Lift Machine of Gearless PMSM of suitable kW with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work Minor civil work for alteration if any and erection of door frames and accessories, erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails fixing of girders for mounting lift machine etc. complete as per specification no. LFT. Lift shaft available having clear size of 1800 mm wide x 1800mm deep. 1000mm Pit depth, 3000mm Overhead. 1) General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. 2) Warrantee: - Job covers three years onsite warrantee for all the Lift parts with FCAMC as per the maintenance schedule. Acceptable makes: Kone / Otis / Schindler’s Elevators /Thyssenkrupp
SITC of BOILER 600 KG/HR Capacity: 600 Kgs/Hr. Technical specifications: Designed as per IBR, M.O.C.: For Shell/Furnace/End Plate : IS-2002 Gr.1 / II or SA-515/516Gr.60/70, Tubes BS-3059, Type : Horizontal, Smoke Tube, Two /Three-pass, Design, Packaged Steam Boiler.Fuel : Coal /Wood, Working pressure: 10.54 Kg/cm2(g) i.e. 150 psig, Thermal efficiency : 75%, Electrical connection:415V / 50 Hz, 3 phase, 4-wire, AC supply Water Feed Pumps:, No. of feed water pump : 2 Nos. (1 working + 1 standby), Capacity : 720 Litre /hr. Motor H.P.:1.0 H.P.,Pollution Control Equipment (Mechanical Dust Collector) With Slide Gate arrangement , IBR piping between feed water pumps and boiler. All mounting & accessories including stop valves, isolation valves, safety valves etc as per manufacturers standard INSTRUMENTS, CONTROLS AND SAFETIES: - Steam pressure indicator (gauge) for measuring steam pressure,Pressure gauge for measuring water pressure., Steam pressure switch for high pressure cut off, Magnetic type water level controller, Temperature indicator cum controller along with RTD Prewired electrical control panel with contactors, relays and MCCB / MCB for motors, power & control cabling, earthing as may be required. Bottom frame and Boiler support structure
Supply &installation of for MS Self Support Chimney Top DIA 450 MM Bottom 1000 MM Shell Thickness 6, 8, 10 MM, Base Plate & Ring, Foundation bolt, First Laval plate form with Monkey Ladder, Aviation Lamp, Lighting Arrester, GI Strip and Insulator.
2.8KL Feed Water Tank DIA 1200 MM Length 3000MM With Structure, Saddle & Main Hole, Required Nozzle Inlet, Outlet, Drain, Over Flow, Laval Gauge, Etc. Fully Insulated.
Supply & installation for MS Ducting Boiler to APH/MDC to ID fan to Chimney with Insulation
Boiler licening with legal fees with drg.skt and its approval
Supply & installation of Complete PRS (Pressure Reducing Station) with Samsung/Karona Equal make, PRV (Pressure Reducing Valve) including IBR Certificate, from 10.54kg/cm2 to 3 kg/cm2
SITC of Pipeline with material and required fitting and Hardware, insulation for a)All Vent, Drain, Blowdown. Feed water tank to pump & return feed tank b)Steam pipeline Boiler to PRS with TC Approx 12 MTR, Material With IBR PRS to Plant of required size, apporx.50MTR complete with steam traps etc as may be required.
Oil injected air compressor withI inbuilt dryer ,inbuilt VFD & inbuilt suitable size of air receiver. The compressor model is 7.5 kW oil injected screw compressor delivering capacity of 46 cfm at 7 bar pressure and it is mounted on receiver tank of suitable capacity. The compressor shall be with inbuilt highly efficient refrigerant dryer suitable for pressure dew point of 3-5 Deg.C. the filters offered shall be Oil aerosol/wet dust filter (maximum oil carry-over of 0.0009 mg/m³), And High performance oil vapor filters Filter ( Maximum oil carry-over 0.003 mg/m³) Accceptable make: Atlas copco / eqvt approved
SITC of SS 304 pipe of various OD as per the requirement with mirror finish complete with ,fittings
Supply & fabrication of support structure (channels/angles/square pipes) in SS304 mirror finish
Supply & installation of manuaaly operated ball valves, strainers, solenoid valves for compressed air and water lines
Cooling Tower: SITC of cooling tower mechanical forced draught /induced draught in FRP construction complete with FRP Casing and tank, distribution header and honey comb PVC evaporative pad. Water collection tank shall be provided. with suction strainer, suction make up [with float], quick fall and overflow connections.The cooling tower fan shall be low speed axial flow type. The fan unit shall be directly mounted on the shaft of the totally enclosed motor and shall be protected by a guard.access ladder shall be provided. The cooling tower shall be designed for capacity as mentioned below. HR capacity: 175 kW Water Flow: 8 lps Cooling range: 37 to 32 Deg C Ambient wet bulb temp: 25 deg C Acceptable make: Mihir / Advance / Paharpur or equivalent make
Approved make Monoblock pump set complete with TEFC squirrel cage induction motor Capacity as specified all wet parts in SS construction (1 working + 1 stand by) Kirloskar/ Grundfoss / wilo/ eqvt Water Flow: 8 lps at 8m head
Water piping, fittings of Tata ‘B’ class G.I. pipes with necessary fittings & LEADER / INTERVALVE /PAPILLON / ADVANCE or equivalent approved make valves as per specifications shall be provided as per Consultant’s approved drawing. Cost of all the necessary fittings, valves, all required supports for piping etc. to be included.
Supplying and erecting Centrifugal water pump (Monoblock), 230V, Single phase 50 cycles A.C. supply of 0.75 KW/1 HP with discharge 1.6/2.9 Litres per second (LPS) for head of 9/22 m &m 40 mm suction/ 40 mm delivery pipe on provided C.C. foundation as per specification
Supplying and erecting Centrifugal water pump (Monoblock), 230V, Single phase 50 cycles A.C. supply of 1.5 KW/2 HP with discharge 7.16/4.16 Litres per second (LPS) for head of 12/21 m & 50 mm suction/ 50 mm delivery pipe on provided C.C.nfoundation as per specification.
Supplying and erecting Centrifugal water pump (Monoblock), 415V, three phase 50 cycles A.C. supply of 2.25KW/ 3 HP with discharge 4.9/9.2 Litres per second (LPS) for head of 10/26 m and 65 mm suction/ 50 mm delivery pipe on provided C.C. foundation as per specification
Supplying and erecting Centrifugal water pump (Monoblock), 415V, three phase 50 cycles A.C. supply of 3.75 KW/5 HP with discharge 2/4.1 Litres per second (LPS) for head of 36/52 m and 50 mm suction/ 40 mm delivery pipe on provided C.C. foundation as per specification
Supplying and erecting D. O. L. Starter suitable for 250V. Single phase, 50 cycles with overload element with necessary materials and connected to supply upto 3 H.P.
Supplying and erecting D.O.L. Starter 400V. 3 phase, 50 cycles with no volt coil and overload element with necessary materials and connected to supply upto 7.5 H.P.
P/F. CPVC or equivalant approved make Pipes (Supreme or equivalent make) with malleable G.I. 'R' brand specials such as tee, bend, elbow, socket, reducing sockets, union, collers etc. as required including cutting, threading and fixing with necessary plumbers gum, making earthwork excavation and re-filling or making wall grooves and re-doing after testing, providing 2-coats of tar paint for all G.I. specials laid under ground or consealed pipe line etc. complete a)20mm dia.
P/F. CPVC or equivalant approved make Pipes (Supreme or equivalent make) with malleable G.I. 'R' brand specials such as tee, bend, elbow, socket, reducing sockets, union, collers etc. as required including cutting, threading and fixing with necessary plumbers gum, making earthwork excavation and re-filling or making wall grooves and re-doing after testing, providing 2-coats of tar paint for all G.I. specials laid under ground or consealed pipe line etc. complete. b)25mm dia.
P/F. CPVC or equivalant approved make Pipes (Supreme or equivalent make) with malleable G.I. 'R' brand specials such as tee, bend, elbow, socket, reducing sockets, union, collers etc. as required including cutting, threading and fixing with necessary plumbers gum, making earthwork excavation and re-filling or making wall grooves and re-doing after testing, providing 2-coats of tar paint for all G.I. specials laid under ground or consealed pipe line etc. complete. b) 32 mm dia .
P/F. UPVC or equivalant approved make Pipes (Supreme or equivalent make) with malleable G.I. 'R' brand specials such as tee, bend, elbow, socket, reducing sockets, union, collers etc. as required including cutting, threading and fixing with necessary plumbers gum, making earthwork excavation and re-filling or making wall grooves and re-doing after testing, providing 2-coats of tar paint for all G.I. specials laid under ground or consealed pipe line etc. complete a)20mm dia.
P/F. UPVC or equivalant approved make Pipes (Supreme or equivalent make) with malleable G.I. 'R' brand specials such as tee, bend, elbow, socket, reducing sockets, union, collers etc. as required including cutting, threading and fixing with necessary plumbers gum, making earthwork excavation and re-filling or making wall grooves and re-doing after testing, providing 2-coats of tar paint for all G.I. specials laid under ground or consealed pipe line etc. complete. b)25mm dia.
P/F. UPVC or equivalant approved make Pipes (Supreme or equivalent make) with malleable G.I. 'R' brand specials such as tee, bend, elbow, socket, reducing sockets, union, collers etc. as required including cutting, threading and fixing with necessary plumbers gum, making earthwork excavation and re-filling or making wall grooves and re-doing after testing, providing 2-coats of tar paint for all G.I. specials laid under ground or consealed pipe line etc. complete. b) 32 mm dia .
P/F. UPVC or equivalant approved make Pipes (Supreme or equivalent make) with malleable G.I. 'R' brand specials such as tee, bend, elbow, socket, reducing sockets, union, collers etc. as required including cutting, threading and fixing with necessary plumbers gum, making earthwork excavation and re-filling or making wall grooves and re-doing after testing, providing 2-coats of tar paint for all G.I. specials laid under ground or consealed pipe line etc. complete. c) 50 mm dia .
P/F. Approved make, heavy duty gun metal ball/gate/wheel valves, fixing in the water supply lines with threaded joints, 25 mm dia:
P/F. Approved make, heavy duty ball/gate/wheel valves, fixing in the water supply lines with threaded joints, 32 mm dia:
P/F. Approved make, heavy duty gun metal ball/gate/wheel valves, fixing in the water supply lines with threaded joints, 50 mm dia:
P/F. rigid PVC soil pipes of I.S. approved make with gasket joints including cost of specials such as door bends, bends, Y, T, door T, reducers etc. as required, making wall or foundation bores & redoing, earthwork excavation & refilling, water testing etc. complete as per instructions. 75mm dia.
P/F. rigid PVC soil pipes of I.S. approved make with gasket joints including cost of specials such as door bends, bends, Y, T, door T, reducers etc. as required, making wall or foundation bores & redoing, earthwork excavation & refilling, water testing etc. complete as per instructions. 110mm dia pipe.
Supply and fixing of internal PVC coving of minimum size of 50mm X 50mm or higher than this suitable size on all wall to floor joints inside the vault . Corner pieces also shall be considered.There shall be sealant applied on edges of the covings as well. KNACON ENVIRO ENGINEERING MODEL : K-85 C /Eqvt
Supply and Installation of Trolleys for Blast Freezer to be made in complete Stainless Steel (SS304L), structurally sturdy to be able to hold the required amount of produce as per the design oad considerations. The number of trolleys would depend on the final design. The trolley shall have heavy duty and robust wheels for easy movement of trolley with load. Wheel material shall be suitable for working in (-) 30 deg C and ambient on a cyclic basis. The quantity given here is in kg to allow flexibility in design. Typical consideration would be 6 trolleys of 450 kg carrying capacity or 8 trolleys of 350 kg carrying capacity each for one blast freezer
Wheels for Trolleys: heavy duty castor wheels in PU/SS construction complete with bracket and all relevant accessories. Suitable for use in food applications.
Part-II: Electrical installation Works
Supply, Installation, Testing & Commissioning of single circuit 33 KV, 3 phase power line on 11.0 mtrs RSJ pole of 152 X 152 mm with an average span of 40 mtrs using rabbit ACSR conductor in congested areas and comprising of 152 x 152 mm RSJ poles of 11.0 Mtrs long, M.S Channel/Angles/Flats of all required sizes, Single DP structure using 11 Mtrs 152 x 152 mm RSJ poles, cross arms, Top Fittings, Pin Insulators, Disc Insulators, Lightning Arrestor, Paint, Guy sets complete, Stay Set, Rabbit ACSR conductor, Earth Electrode, Anti Climbing device, Danger Board, Sundries and harware and including civil work for the same. Complete job as per applicable standards, rules, norms, guidelines of local authorities, statutory requirements.
Supply, Installation, Testing & Commissioning of 33 KV H.T. metering cubical (Compact Type) approved by MSEDCL/Licensee fabricated with 2mm.(14 SWG) M.S.sheets with supporting angle and channel, painted with powder coating / epoxy paint of required shade copper bus bar size 25x6 mm electronic security lock and heavy duty mechanical lock, with counter meter for measuring no of times the opening of doors, top side cover ( C.T.P.T COVER) interlock with meter doors, epoxy coated 3 nos C.T having required ratio between 5/5A to 25/5A, VA10,Class0.5S, 33000/V3/110/V3 VA 50, class 0.5 epoxy terminal block suitable for provided trivector meter, and provision for incoming and outgoing cables etc complete duly tested by Licensee with necessary Test Certificates and erected on Plinth/ C.C foundation, including civil work for plinth.
Supply, Installation, Testing & Commissioning of Non Extendable Outddor type 33 KV 630A, vacuum circuit breaker. Complete job as per applicable standards, rules, norms, guidelines of local authorities, statutory requirements.
Supplying, installing, testing & commissioning 3 phase, 33/0.433 kV, 50 Hz., 800 kVA with OLTC (On Load Tap Changer), oil immersed and naturally cooled outdoor type, copper wound transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40oC by thermometer in oil and 45oC by the resistance in winding at full load rating, with HV tapping (with on load tap changer) on load +5 to -15 in steps of 2.5%, with standard accessories complete with test certificate with losses below 1225 Watts at 50% load, 3450 Watts at 100% load as per IS:1180 - 2014 energy efficiency level II, with necessary permissions of Electrical Inspector, including civil work for plinth.
Supply, Installation, Testing & Commissioning of 3 C x 95 sq.mm. 33 KV XLPE insulated, round armoured, aluminium conductor cable, through provided RCC pipe.
Supply & Installation of heat shrink type 33 KV H.T. termination kits for 3 C x 95 sq.mm. XLPE ( Indoor type ).
Supply & Installation of heat shrink type 33 KV H.T. termination kits for 3 C x 95 sq.mm. XLPE ( Outdoor type ).
Supply, Installation, Testing & Commissioning of earthing station using pipe in pipe earthing electrode with complete system as per specs. Including boring, civil work, chamber etc. Earthing shall be carried out as described in IS-3043-1960 code. Pipe in pipe earthing electrode system shall be as per enclosed technical specifications. The entire earthing system should be executed as per system supplier’s instructions. The Earthing Chamber with all the necessary material required for earthing shall be in Contractors scope. Testing of the Earthing system shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. 2 meters Length Earthing Electrode
Supply, Installation, Testing & Commissioning of earthing station using pipe in pipe earthing electrode with complete system as per specs. Including boring, civil work, chamber etc. Earthing shall be carried out as described in IS-3043-1960 code. Pipe in pipe earthing electrode system shall be as per enclosed technical specifications. The entire earthing system should be executed as per system supplier’s instructions. The Earthing Chamber with all the necessary material required for earthing shall be in Contractors scope. Testing of the Earthing system shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. 3 meters Length Earthing Electrode
Supply & Installation of 32 x 6 mm Galvanized Iron earthing strip & Conductor shall be of High Conductivity. All Necessary Accessories required for installation of Earthing Strips such as Porcelain Insulators, Clamps, Saddles, Hardware, etc will be included in the rate. The Earthing strips connections shall be used as per the provided earthing schedule.
Supply & Installation of 25 x 3 mm Galvanized Iron earthing strip & Conductor shall be of High Conductivity. All Necessary Accessories required for installation of Earthing Strips such as Porcelain Insulators, Clamps, Saddles, Hardware, etc will be included in the rate. The Earthing strips connections shall be used as per the provided earthing schedule.
Supply & Installation of 6" dia RCC half round pipe for covering HT/LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.
Supply & Installation of 6" dia RCC round pipe for HT/LT XLPE cables laid for Road Crossing. Rate shall be inclusive of excavation, back filling and civil work for chambers.
Supply & Installation of 146/150MM dia round HDPE Pipe for LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.
Supply & Installation of 50MM dia round HDPE Pipe for LT cables. Rate shall be inclusive of excavation, back filling and civil work for chambers.
Supply & Installation of chain link fencing section having size 2450 mm in height from ground level and 1200 mm width with 50x50x5 mm support angles & plinth of 400 mm height above ground, double leaf hinged door each1500mm in width x 1850 mm in height using B class ,GI pipe with angle iron supports, chain link wiremesh (jali) complete supported on channel iron, Civil work, stone metals, complete duly painted with one coat of red oxide and two coats aluminum paint., etc all as per EB specifications.
Supply & installation of canopy, made from tubular M.S. pipe having roof of precoated sheet. Job includes necessary civil work. Design of canopy will be approved by our Architects.
Liaisoning Work with Electricity board & Electrical inspector or any other government authority for sanction of electrical load. Job involves preparation of necessary documents with drawings, as required for load application, submission of document files with necessary officials / departments, follow-up with all concerned departments for getting required load sanctioned with estimate for any external H.T. line work., Transformer, 500 KVA DG sets - 2 Nos, Internal & External Electrical Work, Obtaining work completion report from Electrical inspector & board officials. Successfully charging of entire H.T. installation with transformer. Client (Owner) will make all official payments as per the requirement of Electricity board.
Supply & Installation of printed Danger Board/instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Supplying and erecting wall hook 225mm projection for keeping fire buckets made out of 15 mm dia. M.S. Rod grouted in wall to a depth of minimum 15cms complete.
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete.
Supplying standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 & CPRI tested having 2 mm thickness upto 3.3 kV
Supplying and erecting D.C.P. type fire extinguisher 6 kg capacity cartridge type with gun metal cap 150 gram CO2 gas cartridge, powder and brackets conforming to IS 2171-1985/ IS 15683 and complete erected with necessary clamps made from 50x6 mm M.S. flat with nuts & bolts grouted in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Supply, Installation, Testing & Commissioning of 3.5 C x 300 sq.mm, 1.1 KV grade, Stranded aluminium conductor, XLPE insulated, armoured, PVC outer sheathed cables conforming to IS:7098 ( Part-I ). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Cable Tray. Termination of cables using double compression gland, crimping type lugs, etc. Each termination shall include supply of all necessary components, accessories, including double compression cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.
Same as above but with 3.5 C x 240 sq. mm. Stranded Aluminium Conductor.
Same as above but with 3.5 C x 185 sq. mm. Stranded Aluminium Conductor.
Same as above but with 3.5 C x 150 sq. mm. Stranded Aluminium Conductor.
Same as above but with 3.5 C x 95 sq. mm. Stranded Aluminium Conductor.
Same as above but with 3.5 C x 50 sq. mm. Stranded Aluminium Conductor.
Same as above but with 4.0 C x 25 sq. mm. Copper multi stranded.
Same as above but with 4.0 C x 16 sq. mm. Copper multi stranded.
Same as above but with 4.0 C x 10 sq. mm. Copper multi stranded.
Same as above but with 4.0 C x 6 sq. mm. Copper multi stranded.
Same as above but with 4.0 C x 4 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 6 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.
Same as above but with 2.0 C x 2.5 sq. mm. Copper multi stranded.
Same as above but with 19.0 C x 2.5 sq. mm. Copper multi stranded.
Supply & Installation of 4.0 C x 6 sq. mm 1.1 KV grade, Multi Stranded Copper conductor, PVC insulated, PVC outer sheathed cables conforming to IS:694 (1990). The rates shall be inclusive of laying of cable in provided Trench/Pipe/Conduit/Cable Tray. Testing of the cables shall be as per specification & results shall be submitted to Engineer-in-Charge duly signed by contractor and authorized representative. Before Commissioning of cables Contractor need to check for physical damages & proper connection of all the terminals.
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.
Termination of 4.0 C x 6 sq. mm, LT copper flexible cables using PVC cable gland of IP65, crimping type Copper lugs, etc. Each termination shall include supply of all necessary components, accessories, including PVC cable gland, cable lugs (crimping type) and consumables to make a complete termination in such a way that no live parts of the terminal and connecting lugs are exposed. While making termination, all other protection arrangement shall also be ensured. The cable tagging with proper ferrules shall be supplied & installed by the Contractor as part of cable termination work.
Same as above but with 4.0 C x 4.0 sq. mm. Copper multi stranded.
Same as above but with 3.0 C x 2.5 sq. mm. Copper multi stranded.
Supply & Installation of 300 x 75 mm, Perforated type cable trays made out of 16 G CRCA sheet & Hot Dipped galvanized, with support at every 1.5 mt. interval using M.S. angle of size 40x40x5 mm Or Using Suspension GI rods. M.S. Support shall be painted with two coats of red oxide primer & two coats of silver paint. All necessary accessories required for installation of cable trays such as Cable Tray Supports, Clamps, Flat Strips, Joints, Hardware, etc shall be included in Installation rate.
Same as above but of size 200 x 75 mm.
Supply & Installation of 300 x 20 mm, cable tray cover made out of 18 G CRCA sheet & Hot Dipped galvanized, with all necessary accessories required for installation of cable tray covers such as Clamps, Flat Strips, Joints, Hardware, etc shall be included in Installation rate.
Same as above but of size 200 x 40/50 mm.
Supply, Installation, Testing & Commissioning of conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on 5 meters height, The Lightning protection includes the Lightning counter comprising of digital display in an IP 67 enclosure with the minimum sensitivity of 1500A & maximum capacity of 220 KA counter & it should be tested as per IS/IEC, The Job also includes supporting mast using Galvanized Iron pipe of 3 meter length plus 2 meter pipe of FRP complete with base plate, Guy rope wires, Insulator, Clamps, Fasteners, Fan Hooks, hardware, etc.
Supply, Installation, Testing & Commissioning of Primary light point wiring with 1.5 sq.mm. PVC insulated FRLS multistranded copper conductor wires, through PVC conduit concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch, with concealed/surface box, modular surface plate, ceiling rose/holder etc.
Supply, Installation, Testing & Commissioning of Secondary light point wiring with 1.5 sq.mm. PVC insulated FRLS multistranded copper conductor wires, through PVC conduit concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch, with concealed/surface box, modular surface plate, ceiling rose/holder etc.
Same as above but control shall be two way.
Supply, Installation, Testing & Commissioning of fan point wiring with 1.5 sq.mm. PVC insulated copper conductor FRLS wires, through PVC conduit, concealed or surface mounted on ceiling/wall, point shall be controlled by 6 A modular type switch & step type electronic fan regulator with concealed/surface box, modular surface plate etc.
Same as above but on lighting switch board ( Half Pt.).
Supply, Installation, Testing & Commissioning of 6 Amp. socket point wiring with 2x1.5+1x1.0 sq.mm.PVC insulated copper conductor FRLS wires, through PVC conduit, concealed or surface mounted on the ceiling/wall, with modular type 6 Amp. switch & 5 pin socket, concealed/surface box, modular surface plate etc.
Supply, Installation, Testing & Commissioning of 6 A sockets with modular type switches, concealed/surface box, modular surface plate etc., without any wiring & conduit ( wiring & conduit will be measured in mains ).
Supply, Installation, Testing & Commissioning of 6/16 A socket point wiring with 2x2.5+1x1.5 sq.mm.PVC insulated copper conductor FRLS wires, through PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type 16 Amp. switch & 6/16 A socket, concealed/surface box, modular surface plate etc.
Supply, Installation, Testing & Commissioning of 6/16 A socket point with modular type switches, concealed/surface box, modular surface plate etc., without any wiring & conduit (wiring & conduit will be measured in mains ).
Supply, Installation, Testing & Commissioning of Bell point wiring with 1.5 sq.mm, Bell push button, Bell buzzer all modular typr, PVC insulated copper conductor FRLS wires, through PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type bell push and reset type bell with indicator.
Supply, Installation, Testing & Commissioning of telephone point wiring with 2 pair telephone wire, through provided PVC conduit, concealed/surface mounted on the ceiling/wall with modular type RJ11 telephone socket, concealed/surface box, modular surface box etc. ( Telephone wire & PVC conduit will be measured separately ).
Supply, Installation, Testing & Commissioning of TV point wiring with RG 6 co-axial cable, through provided PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type TV socket, concealed/ surface box, modular surface plate etc. (RG 6 cable & PVC conduit will be measured separately ).
Supply, Installation, Testing & Commissioning of data outlet sockets with CAT 6 UTP cable, through provided PVC conduit, concealed/surface mounted on the ceiling/wall, with modular type RJ 45 data outlet socket, concealed/surface box, modular surface plate and connection at both ends. ( CAT 6 UTP cable & PVC conduit will be measured separately ).
Supply & Installation of 25mm medium duty PVC conduit with standard accessories and to be used for concealed / surface mounted on the ceiling/wall.
Same as above but with 32 mm
Supply & Installation of 25 mm wire reinforced type flexible PVC conduit with PVC glands on both sides to be used for flexible copper wires / cables.
Same as above but with 32 mm
Supply, Installation, Testing & Commissioning of mains / sub-main wiring using FRLS type wires of 2x2.5 sq.mm. + 1x1.5 sq.mm. PVC insulated, multistranded copper conductor through existing PVC conduit. ( Measurement of conduit & wires shall be separate ).
Same as above but with 2x4.0 sq.mm. + 1x2.5 sq.mm.
Same as above but with 6.0 sq.mm
Same as above but with 4.0 sq.mm
Same as above but with 2.5 sq.mm
Supply, Installation, Testing & Commissioning of telephone wires of 2 pair with 0.5 mm dia. through existing PVC conduit.
Supply, Installation, Testing & Commissioning of Jelly filled armoured telephone cable of 10 pair with 0.5mm dia liad through existing HDPE pipes
Supply & Installation of 10 pair krone type telephone junction box.
Supply, Installation, Testing & Commissioning of Co-axial cable low voltage grade RG-11 through existing PVC conduit.
Supply, Installation, Testing & Commissioning of CAT 6 UTP data cable through existing PVC conduit.
Supply & Installation of 100x50 mm PVC plastic trunking with flexible cover, base joint, aluminium clip on partition, end caps, internal angle, clips etc.
Supply & Installation of 'B' grade GI pipe down rod duly painted for fan complete erected with PVC three core flexible cable of 1 sqmm copper PVC wire.
Supply, installation, testing & commissioning of 12 way VTPN MCB DB with double door, comprising of following: Incoming : 125 A 4 pole 36 KA MCCB with with adjustable thermal, fix magnetic release, spreader links, phase barrier etc. 1 No. Outgoing : 32 A 3 pole 10 KA MCB. 12 Nos.
Supply, Installation, Testing & Commissioning of 4 way VTPN MCB DB with double door, comprising of following: Incoming : 63 A 4 pole MCB 10 KA 1 No. Outgoing : 32 A 3 pole MCB. 10 KA. 3 Nos. 16 A 1 pole MCB. 10 KA. 3 Nos.
Supply, Installation, Testing & Commissioning of 8 way PPI MCB DB with double door, comprising of following: Incoming : 32 A 4 pole MCB 10 KA 1 No. 32 A DP RCCB 30 mA Hpi type. 3 Nos. Outgoing : 10 A 1 pole MCB. 10 KA. 18 Nos.
Supply, Installation, Testing & Commissioning of 4 way PPI MCB DB with double door, comprising of following: Incoming : 25 A 4 pole MCB 10 KA 1 No. 25 A DP RCCB 30 mA Hpi type. 3 Nos. Outgoing : 10 A 1 pole MCB. 10 KA. 6 Nos.
Supply, installation, testing & commissioning of 8 way SPN MCB DB with double door, comprising of following: Incoming : 25 A DP RCBO 30 mA Hpi type. 1 No. Outgoing : 10 A 1 pole 10 KA MCB. 4 Nos.
Supply, installation, testing & commissioning of 8 way SPN MCB DB with double door, comprising of 25/32 A FP MCB 10 KA 2 Nos.
Supply, Installation, Testing & Commissioning of MCB & socket boxes of IP 65 annd having 16 Amp. DP MCB 10 KA with 16 Amp. 1 Ph. 3 pin Socket & 32 Amp. FP MCB 10 KA with 32 Amp. 3 Ph. 4 wire with E socket. PVC Box shall be combine for both the sockets.
Supply, Installation, Testing & Commissioning of MCB & socket boxes of IP 65 and having 16 Amp. DP MCB 10 KA with 16 Amp. 1 Ph. 3 pin Socket & 16 Amp. FP MCB 10 KA with 16 Amp. 3 Ph. 4 wire with E socket. PVC Box shall be combine for both the sockets.
Supply, Installation, Testing & Commissioning of 6 to 32 A DP MCB with MS box.
Supply, Installation, Testing & Commissioning of 125 Amp, 4 pole Onload bypass switch with Metal Enclosure box. All necessary components / accessories required for installing & commissioning of UPS bypass switch will be included in installation rate.
Supply, Installation, Testing & Commissioning of On line UPS pure sine wave of 10 kVA capacity complete with standard features, along with necessary SMF batteries for 120 mins battery backup for full load and as per specification, Battery Rack, Interconnecting cables, etc.
Supply, Installation, Testing & Commissioning of IP 65, PVC Junction box with 4way connectors & earthing terminal inside.
Supply, Installation, Testing & Commissioning of IP 65, PVC Junction box with 2way connectors & earthing terminal inside.
Supply, Installation, Testing & Commissioning of 39/40 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy >90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.
Supply, Installation, Testing & Commissioning of 20 Watt LED Capsule type IP 65 protection, suitable for surface mounting. System Efficacy >90, Colour Temp 6500K, CRI Value minimum 80, Operating Temperature is 0 Deg. Driver having voltage range of 120 - 300 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection. Complete with mounting bracket suitable for Surface mounting, wiring etc.
Supply, Installation, Testing & Commissioning of 15W LED Recess mounted Round Downlighter, 6500K, IP20, System Efficacy >90, CRI Value minimum 80, Driver having voltage range of 140 - 280 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection.
Supply, Installation, Testing & Commissioning of 9W LED Surface mounted Round Downlighter, 6500K, IP20, System Efficacy >90, CRI Value minimum 80, Driver having voltage range of 140 - 280 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >=2.5 KV, inbuilt over voltage & under voltage protection.
Supply, Installation, Testing & Commissioning of 7 watt (Colour Temp 5700/6000K)direct fitting LED bulbs.
Supply, Installation, Testing & Commissioning of 7 watt (Colour Temp 4000K)direct fitting LED bulbs.
Supply, Installation, Testing & Commissioning of 7 watt (Red) direct fitting LED bulbs.
Supply, Installation, Testing & Commissioning of 7 watt (Yellow) direct fitting LED bulbs.
Supply, Installation, Testing & Commissioning of 7 watt (Blue) direct fitting LED bulbs.
Supply, Installation, Testing & Commissioning of Pole mounted 90 watt LED Street Light, IP65 protection, luminaire with ADC housing & clear cover, Wall mounting bracket and accessory suitable for outdoor installation. System Efficacy >100, Colour Temp 6500K, CRI Value minimum 80, Driver having voltage range of 110 - 290 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >= 4 KV, inbuilt over voltage & under voltage protection. Mounting height of the fitting will be around 9.0 meters.
Supply, Installation, Testing & Commissioning of Pole mounted 90 watt LED Flood Light, IP65 protection, luminaire with ADC housing & clear cover, Wall mounting bracket and accessory suitable for outdoor installation. System Efficacy >100, Colour Temp 6500K, CRI Value minimum 80, Driver having voltage range of 110 - 290 Volts, THD less than 10%, P.F. greater than 0.95, surge protection >= 4 KV, inbuilt over voltage & under voltage protection. Mounting height of the fitting will be around 9.0 meters.
Supply, Installation, Testing & Commissioning of Integral LED post top 40 watt fitting, complete with wiring etc.
Supply, Installation, Testing & Commissioning of 12.5m (clear height) Fixed type High Mast (Top-110mm, Bottom- 242 mm) with hexagonal/round bracket and foundation bolts suitable for max. 6 nos floodlight fixtures on M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete.
Supply, Installation, Testing & Commissioning of 9 m high (clear height) galvanised octagonal pole with galvanised 1000mm single arm sword type bracket with FRP dome and ballwith foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete.
Supply, Installation, Testing & Commissioning of 1200 mm sweep 5 star rated ceiling fan with double bearing complete with wiring etc.
Supply, Installation, Testing & Commissioning of 225 mm sweep fresh air cum exhaust fan with bird screen.
Supply, Installation, Testing & Commissioning of 375/380 mm sweep heavy duty exhaust fan with bird screen.
Supply, Installation, Testing & Commissioning of 450 mm sweep heavy duty exhaust fan with bird screen.
Supply, Installation, Testing & Commissioning of audio, visual alarm system for cold storage rooms. Job involves solid state Annunciator with hooter & enclosure, 20 mins power backup, installed in occupied area, stay-put type push button station in each cold rooms / pre cooling rooms, cabling from cold rooms / pre cooling rooms to Annunciator. Job involves following items. 16 points Annunciator - 1 No Stay-put type push buttons. - 13 Nos. 2Cx0.75 sq. mm.Copper Flexible multi stranded cable. - 350 Mtrs Medium duty PVC conduit of 25 mm size with standard accessories. - 150 Mtrs
Supply, Installation, Testing & Commissioning of audio, visual alarm system for cold storage rooms. Job involves solid state Annunciator with hooter & enclosure, 20 mins power backup, installed in occupied area, stay-put type push button station in each cold rooms / pre cooling rooms, cabling from cold rooms / pre cooling rooms to Annunciator. Job involves following items. 4 points Annunciator - 1 No Stay-put type push buttons. - 4 Nos. 2Cx0.75 sq. mm.Copper Flexible multi stranded cable. - 100 Mtrs Medium duty PVC conduit of 25 mm size with standard accessories. - 50 Mtrs
Part-III: FIRE FIGHTING, ALARM & DETECTION SYSTEM
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of fire service main multi stage pump, of 2400 LPM at 88 m head centrifugal type, 75 HP (55 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no.FF-MFP/MSC
Supplying, fixing, testing & commissioning of Standby Fire Pump (Diesel driven) with cast iron casing & bronze or phosphor bronze internal parts, complete with coupling guard, foundation,capable of discharging 2250 LPM against 70 metre head against all losses complete with suitable diesel engine, auto start facility with battery, nessesary wiring, fuel tank, exhaust system, guages & wired for automatic start of the water pump on drop of pressure in the wet riser/ hydrant and sprinkler system. The motor starter and pump should confirm to LPA / BSES & and IE Regulations. The pump shall be capable of giving not less than 150% discharge at a head not less than 65% of the rated head. complete.
Supplying installing, testing, commissioning with perfect aligning, proper levelling of Jockey Pump of 240 LPM at 56 m head, 3 ph. 415 A.C.15 HP, (11 kW) or of suitable HP with suitable Stages as per specification No. FF-MFP/JP
Fabrication, supplying, fixing, testing & commissioning of Electrical Control Panel of cubical construction, floor mounted type fabricated out of 2mm Thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after treatment process, cable alley, inter-connection, having switchgears and accessories mounting and internal wiring, earth terminals, numbering etc., complete in all respects suitable for operation on 415 V, 3 phase, 50 Hz. AC supply with enclosure protection class IP 42 as required.
Suuplying, Laying of XLPE insulated, PVC sheathed alluminium conductor 1.1 KV grade armoured Cable of following sizes on surface / in existing cable tray suitably clamped as required with glands.
3 ½ core 70 sq.mm
3 ½ core 25 sq.mm.
Supplying, fixing of 25mm x 5mm GI strip in 40mm dia G.I. pipe from earth electrode as required.
Supplying and installing G.I. pipe above ground of ‘C’ class ERW conforming to IS: 1239, alongwith necessary fittings and M.S. angle iron supports, with one coat of red oxide primer and two coats of Post office fire red enamel paint, duly tested to 1.5 times of working pressure, in an approved manner.
Supplying and erecting G.I.pipe of ‘C’ class ERW of size 200 mm dia with necessary fittings complete as perspecification no.FF-PP
Supplying and erecting G.I.pipe of ‘C’ class ERW of size 150 mm dia with necessary fittings complete as perspecification no.FF-PP
Supplying and erecting G.I.pipe of ‘C’ class ERW of size 100 mm dia with necessary fittings complete as perspecification no.FF-PP
Supplying and erecting G.I.pipe of ‘C’ class ERW of size 80 mm dia with necessary fittings complete as perspecification no.FF-PP
Supplying and erecting G.I.pipe of ‘C’ class ERW of size 65 mm dia with necessary fittings complete as perspecification no.FF-PP
Supplying and erecting G.I.pipe of ‘C’ class ERW of size 50 mm dia with necessary fittings complete as perspecification no.FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system.
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Providing coating of bitumen paint & 4mm thick wrapping for underground 200 mm ring main of fire fighting system.
Excavating Hard Murum/metal road (B.T.)by chiseling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.
Supplying, fixing, testing & commissioning of double flanged metallic expansion joint (expansion bellows) of standard length as per manufacturers specs including provoding necessary rubber gaskets, flanges, nuts, bolts and washers complete as required.
150 mm dia
80 mm dia
Supplying and installing cast iron Butterfly valve with EPDM rubber gasket conforming to IS:5312 (Part-I) PN1.6 with nut bolts, gaskets etc. and tested to1.5 times of working pressure, in an approved manner.
Supplying & erecting cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 75/80 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 65 mm dia. complete as per specification no. FF-VL/BFV
Supplying and installing double flange NRV conforming to IS:5312 (Part-I), ISI marks, PN1.6 having cast iron body and gun metal working parts with nut bolts, gaskets, etc. and tested to 1.5 times of working pressure in an approved manner.
Supplying and erecting cast iron double flange NRV of size 150 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange NRV of size 100 mm dia complete as per specification no. FF-VL/NRV
Supplying and erecting cast iron double flange NRV of size 65 mm dia complete as per specification no. FF-VL/NRV
Supplying and fixing, testing & Commissioning of `Y' strainer with bronze perforated sheet basket including rubber gasket, flanges, nuts, bolts and washers, complete as required.
150 mm dia
65 mm dia
Supplying and installing gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification No. FF-VL/HV
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying, fixing, testing & commissioning of 63 mm dia instantaneous pattern, SS short branch pipe (conforming to SS-304),20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required.
Supplying and erecting fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FBC
Supplying, fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm, in height with air release valve on top and flanged connection to riser, drain arrangement with 25mm dia Gun metal wheel valve, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.
Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FFFFA/ PG
Supplying, Fixing of Weather proof cabinet fabricated from 16 gauge M.S. Sheet with Double glazed door having locking arrangement ,painted "fire Red" with powder coated paint "Fire Hose" written on front including suitable supports to Place 900 mm above ground level ,approximately size 750 x 600 x 250 mm deep ( To house Two lengths of Canvas hose with coupling , branch pipe and nozzle and accessories which includes hammer and set of duplicate keys) for External/Internal Hydrants.
Supplying , fixing of First-Aid-fire Hose reel wall mounting swinging type complete with Standrad fire hose reel with 20 mm dia. High preesure rubber hose 36.5 mtrs. Long with SS nozzle and control valve ,shutoff valve , all mounted on circular hose reel of heavy duty mild steel construction and cast iron brackets. Hose reel shall confirm to IS: 884 -1969 and rubber hose to IS : 5132 . Hose reel shall be connected directly to Wet Riser
Supplying and erecting fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. FFFA/ FBC
Supplying and erecting Fire resistant Mortar(20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings with all kinds of cables, pipes and cable support system in steel and aluminium and plastic profiles ( Except hollow core conductors). The residual openings shall be closed with filler, as per specification No. FF-FRM
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Supplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete.
Providing and fixing Photo Illuminicent 12x6 inch Exit Signages.
Providing Round bottom FIRE Bucket of 9 Litrescapacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated
Supplying, erecting, testing and commissioning of 15 mm (½") dia. NBCM Body chrome finished quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR
Supplying & fixing of Flow Switches.
Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and installing G.I. pipe above ground of ‘C’ class ERW conforming to IS: 1239, alongwith necessary fittings and M.S. angle iron supports, with one coat of red oxide primer and two coats of Post office fire red enamel paint, duly tested to 1.5 times of working pressure, in an approved manner.
Supplying and erecting G.I.pipe of ‘C’ class ERW of size 100 mm dia with necessary fittings complete as perspecification no.FF-PP
Supplying and erecting G.I.pipe of ‘C’ class ERW of size 80 mm dia with necessary fittings complete as perspecification no.FF-PP
Supplying and erecting G.I.pipe of ‘C’ class ERW of size 50 mm dia with necessary fittings complete as perspecification no.FF-PP
Supplying and erecting G.I.pipe of ‘C’ class ERW of size 32 mm dia with necessary fittings complete as perspecification no.FF-PP
Supplying and erecting G.I.pipe of ‘C’ class ERW of size 25 mm dia with necessary fittings complete as perspecification no.FF-PP
Supplying, fixing, testing & commissioning of installation control valve of Cast Iron body and brass / bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser / Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc. of size 100 mm dia as required.
Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF-VL/BFV
Supplying, fixing, testing & commissioning of gun metal gate valves of following sizes;
25 mm dia for air release + test valve.
50 mm dia for drain.
Supplying, fixing, testing & commissioning of 1 loop addressable control panel with loop cards, 230 V ac and sounder circuits with battery back up.
Supplying, fixing, testing & commissioning of Analogue addressable Multisensor detector
Supplying, fixing, testing & commissioning of Analogue addressable Photoelectric Smoke detector
Supplying, fixing, testing & commissioning of Analogue addressable Heat detector with base.
Supplying, fixing, testing & commissioning of Analogue addressable Manual Call Point
Supplying, fixing, testing & commissioning of Analogue addressable Hooter Cum Strobe.
Supplying, fixing, testing & commissioning of Control Module
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CBLT/ CU
Supplying, fixing, testing & commissioning of PVC Conduit pipe / Cassing Capping Patti.
Supplying, fixing, testing & commissioning of SMOKE/FIRE ALARM Siren Range 1.0 km.
LAISIONING CHARGES FOR PROVISIONAL FIRE NOC FROM LOCAL FIRE OFFICE AND GET DRAWINGS APPROVED BEFORE STARTING WORK AND TO OBTAIN FINAL FIRE NOC
Covid-19 Health and safety: Providing and making necessary arrangements of various essential materials and items of recommended quality and make as per guidelines of the health department required for prevention of COVID-19 pandemic in consideration of health and safety management of man power at construction site 1. Hand Sanitizer. 2. Disinfectant. 3. Sodium Hypochlorite. 4. Fogging machine and Liquid for sanitization. 5. 3 Ply Face Mask of good quality. 6. Surgical / Latex Gloves of good quality. 7. Rubber Gloves of good quality. 8. Empty Spray Bottles (Plastic). 9. PPE kits. 10. Temperature Guns. 11. Face shield
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid