Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹17.1 LAccepted-AOC D 55 HAKIKAT RAI RD ADARSH NAGAR DELHI 33 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹20.0 L+₹2.3 L (12.9%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L-2 | Rejected-Finance L-2 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
20 Jun 2023, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
REPAIR/MAINTENANCE OF ACS AND OTHER APPLIANCES, UNDERGROUND PIPE LINES, CENTRIFUGAL PUMP SETS AND VARIOUS ASSETS INSTALLED AT WATER SUPPLY INSTALLATIONS AT AF STN DADRI IN AOR OF GE (AF) FARIDABAD (2ND CALL)
2023_MES_590662_2
GE (FBD)/AF-05/2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DADRI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) FARIDABAD
₹60,000
Yes
2 Aug 2023
6 Jun 2023
22 Jun 2023
6 Jun 2023
20 Jun 2023
6 Jun 2023
Amount
M&L for servicing of Indoor unit & Out door unit of Split type AC of 1.5 tone capacity by taking out the same from existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part and reinstall at the same location and clean water with water pressure gun, greasing of fan , motor , blower etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 01 but split type AC of 2.0 ton complete all as specified and directed by Engineer-in-Charge
M&L for servicing of Window type AC of 1.5 tone capacity by taking out the same from existing location , cleaning of condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution and clean water, greasing of fan , motor , blower etc without damage any part and reinstall at the same location complete all as specified and directed by Engineer-in-Charge
M&L for finding out the leakage the pressure test of the condenser of cooling coil of window type AC/split AC of 1.5 /2.0 ton and dismantling the same for repair the leakage point by brazing/ soldering including charging the gas R-22 and testing the AC to the entire satisfaction of Engineer-in-Charge
M&L for finding out the leakage the pressure test of the condenser of cooling coil of window type AC/split AC of 1.5 /2.0 ton and dismantling the same for repair the leakage point by brazing/ soldering including charging the green R-410/309 etc or equilvent as required on site and testing for satisfactiory working condition complete all as specified and directed by Engineer-in-Charge
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed by Engineer-in-Charge Make :- L&T, ABB, SCHNEIDER, SIEMENS,LEGRAND, HAGER
M&L for Sub main wiring with two single core, 4 Sqmm, PVC insulated PVC unsheathed stranded FR copper conductor cable in and including PVC concealed/ surface conduit of earth wire with 1 x 2.5 Sq mm copper cable fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge Make:- FINOLEX, GRANDLAY, HAVELLS, POLYCAB
M&L in repair for taking out unserviceable sealed unit (compressor) 1.5 ton capacity , single phase, 230 volt of models as existing and replacing the same with new sealed unit (compressor) including necessary modification of the foundation as required to suit the compressor, vacumacation , pressure , testing, leaking, rectification incl gas charging R-22 and testing complete all as specified and directed by Engineer-in-Charge
All as per item No 08 above but 2 TR complete all as specified and directed by Engineer-in-Charge
All as per item No 08 above but suitable for refrigerent R 410a for 1.5 TR complete all as specified and directed by Engineer-in-Charge
All as per item No 08 above but suitable for refrigerent R 410a for 2 TR complete all as specified and directed by Engineer-in-Charge
M&L for Split AC outdoor unit body only of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge
M&L for Removing the split type AC 1.5 ton/ 2 ton capacity working on 230 V single phase /440 Volt 3 phase complete including indoor and out door unit all as directed including making good of all disturbed surfaces complete all as specified and directed by Engineer-in-Charge
M&L for reinstall at any place ( with in the stn ) at height up to 5 mtr from floor level including replacement of refrigerant tubing upto 7.5 mtrs length and provision of drain pipe and pipe insulation, connecting with existing power socket and testing the unit for smooth functioning all as directed including making good of all disturbed surfaces complete all as specified and directed by Engineer-in-Charge
M&L for Split AC Indoor unit of capacity 1.5 TR complete all as specified and directed by Engineer-in-Charge Make:- VOLTAS, HITACHI,DAIKIN,O-GENERAL CARRIER, FEDDERS LLYOD
S & F PCB card suitable of 1.5/2 ton split AC suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engineer-in-Charge including replacement of defective electronic components / IC Circuits
S & F PCB card suitable of 1.5/2 ton Inverter split AC suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engineer-in-Charge including replacement of defective electronic components / IC Circuits
S & F Corded remote controller suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engineer-in-Charge
S & F Air filter suitable for 1.5/2 split type AC suitable of 1.5/2 ton split AC as required on site incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge Make:- MIHIR, DANFOSS,INDFOSS,KLENZOID JOHN FOWLERS
S & F Thermostat suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engr-in-Charge Make :- DANFOSS, HONEY WELL,SIEMENS, JOHNSON, RAPIDCOOL
S & F Single pole contractor for Split type AC 50/60 Hz 240 V complete all as specified and directed by Engineer-in-Charge
S & F Axilary contactor single phase 220 Volts 10 Amps current capacity complete all as specified and directed by Engineer-in-Charge
S & F Start Relay suitable of 1.5/2 ton split AC as required on site complete all as specified and directed by Engr-in-Charge
Supply and replace copper condenser coil assembly complete suitable for 1.5 / 2 ton window/ split type AC incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge
Supply and replace evaporator coil assembly complete suitable for 1.5 / 2 ton Window / Split type AC incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge
S & F Copper pipe 5 /8" complete with insulation of thickness 10 mm incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge Make:- DIAMOND, STAR
S & F Copper pipe 3 /8" complete with insulation of thickness 10 mm incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge Make:- DIAMOND, STAR
S & F Copper pipe 1 /4" complete with insulation of thickness 10 mm incl testing for satisfactry working condition complete all as specified and directed by Engineer-in-Charge Make:- DIAMOND, STAR
S&F condensing fan motor of capacity suitable for Split AC 1.5/2 Ton testing on load for the entire complete all as specified and directed by Engineer-in-Charge Make:- CROMPTOM GREAVES, Khaitan, USHA, Voltas
S&F in repairs running capacitor of capacity ‘45+5’ MFD, 240 volts, 50 Hz complete all as specified and directed by Engineer-in-Charge
All as per item No 30 above but capacity 36 MFD complete all as specified and directed by Engineer-in-Charge
S&F in repairs blower fan motor of capacity 1/30 HP, 3 speed, single phase complete all as specified and directed by Engineer-in-Charge Make:- CROMPTOM GREAVES, Khaitan, USHA, Voltas
S&F in repair condenser fan motor of capacity 1/20 HP, single phase complete all as specified and directed by Engineer-in-Charge Make:- CROMPTOM GREAVES, Khaitan, USHA, Voltas
S&F in repair starting capacitor of capacity 6 MFD, 40 volt, 50 Hz complete all as specified and directed by Engineer-in-Charge
S&F in repairs starting capacitor of capacity 100-120 MFD , 440 volts, 50 Hz complete all as specified and directed by Engineer-in-Charge
S&F in repairs wiring kit for capacity 1.5 ton AC complete all as specified and directed by Engineer-in-Charge
S&F repair & replacement of 1/30 HP fan blower motor of cooling unit of split AC unit with supper enameled copper wire of suitable gauge wire Make: Chetak/ Devi Dayal/ Usha including replacement of the shaft and bushes and testing on load for the enter complete all as specified and directed by Engineer-in-Charge
All as per item No 37 above but 1/20 HP condensing fan motor complete all as specified and directed by Engineer-in-Charge
S&F in repair MCB 25A, ‘C’ curve type complete all as specified and directed by Engineer-in-Charge Make :- L&T, SCHNEIDER, SIEMENS,LEGRAND, HAGER
S&F in repairs of cable 3 core 4 sqmm FRLS PVC copper conductor complete all as specified and directed by Engineer-in-Charge Make:- FINOLEX, HAVELLS, HPL, POLYCAB
M&L for servicing of Refrigerator any size at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location complete all as specified and directed by Engineer-in-Charge
M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of capacity 253 Ltr as existing make including charging of refrigerant gas F-134 and testing on full load complete all as specified and directed by Engineer-in-Charge
All as per item No 42 above but capacity of refrigerator 310 Ltr complete all as specified and directed by Engineer-in-Charge
M&L for servicing of Deep freezer of size 320 Ltr at existing location , cleaning , dusting, brushing, checking and rectify electrical conections, condenser , cooling coil and other components with cooling coil and other components with cooling coil rinse solution without damage any part at the same location complete all as specified and directed by Engineer-in-Charge
M & L for replacement of unserviceable sealed compressor with new hermetic sealed compressor of capacity 320 Ltr as existing make including charging of refrigerant gas F-134 and testing on full load complete all as specified and directed by Engineer-in-Charge
M & L for servicing of Water cooler of any capacity at existing location by cleaning of condenser, cooling coil, and other components with cooling coil Rinse solution & clean water, greasing of fan, motor including cleaning of storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of complete all as specified and directed by Engineer-in-Charge
M & L for taking out unserviceable sealed unit (compressor) of water cooler 150/150 Ltrs capacity single phase 230 volt of as existing model and replacing the same with new sealed unit (Compressor ) including necessary modification of the foundation as required to suit the compressor, vacumisation presser testing, leakage rectification, charging of gas R-134 and testing complete all as specified and directed by Engineer-in-Charge
All as per item No 47 above but compressor as existing model and replacing the same with new sealed unit (Compressor) for water cooler 80/40 Ltr capacity complete all as specified and directed by Engineer-in-Charge
Replacement of wiring kit for water cooler of any make and capacity complete all as specified and directed by Engineer-in-Charge
M & L for replacement of condensing fan motor 1/32 HP of water cooler complete all as specified and directed by Engineer-in-Charge Make:- KIRLOSKAR ELECTRIC CROMPTOM GREAVES, SIEMENS, Khaitan, USHA
All as per item No 50 above but fan motor capacity 1/16 HP complete all as specified and directed by Engineer-in-Charge Make:- KIRLOSKAR ELECTRIC CROMPTOM GREAVES, SIEMENS, Khaitan, USHA
M&L for replacement of float valve ½ dia suitable for water cooler complete all as specified and directed by Engineer-in-Charge Make:- AUDECO, ADVANCE, DEEPAK, ZOLOTO
M & L for servicing of desert cooler of any capacity at existing location by cleaning of all components components with Rinse solution & clean water, greasing of fan, motor including cleaning of water storage tank with treated water after applying the potassium permanganate solution etc without damage any parts incl replacement of small parts like PVC water distributer, flexible pipe, plugs etc as required on site complete all as specified and directed by Engineer-in-Charge
M & L for scraping and removing old paint of desert cooler body (steel surfaces) and preparation of steel surfaces including necessary denting, cutting, welding etc for spray painting with approved smoke gray synthetic enameled paint (Ist quality) over a coat of Zinc chromate primer on outer surface and inner surface i.e. Water tank and body fan mounting blades shall be painted with a coat of anticorrosive black paint over a coat of Zinc chromate primer complete for desert cooler of any size and capacity complete all as specified and directed by Engineer-in-Charge
S & F Desert cooler Pump as per existing capacity complete all as specified and directed by Engineer-in-Charge Make:- CALAMA, KIRLOSKAR, BEACON, KSB, GRANDFOS,CRI
M & L for replacement of desert cooler motor of any make with supper enameled copper wire (Thermal class E) of appropriate size including replacement of gun metal bushed and steel shaft complete all as specified and directed by Engineer-in-Charge Make : Bajaj/ Khaitan/ symphony/Usha
M & L for replacement of cooling fan motor supporting legs and PVC fan blade of 450 mm sweep for desert cooler complete all as specified and directed by Engineer-in-Charge Make:- KIRLOSKAR ,ELECTRIC CROMPTOM GREAVES,/ Bajaj, Khaitan
M & L in replacement of 01 Nos front grill and 3 side loovers suitable for desert cooler duly spray painted with approved paint over a coat of red oxide primer and internal surface of body shall be painted with two coat of bituminous paint over a coat of red oxide primer as required on site complete all as specified and directed by Engineer-in-Charge
M & L for replacement of wood wool pad 25mm thick duly winded with the nylon mesh of standard size for 4000 cum/hr capacity desert coolers complete all as specified and directed by Engineer-in-Charge
M & L for replacement of running cap 4.0 MFD 440 volt complete all as specified and directed by Engineer-in-Charge
M & L for replacement of MS body desert cooler body 660x660x900mm with front grill and three side louver fabricated out of 22 gauge mild steel plan black sheet and bottom water tank (sump) of size 660x660x200mm deep fabricated out of 20 gauge milled steel plan black sheet including taking out and reinstallation complete with standard fitting such as PVC pipe for water electric controls and switch, fan speed regulator rewiring of fan motor and water lifting pump including fixing and connecting existing cooler fan and electric pump with 3 core PVC insulated & PVC sheathed cables (min3 mtr in length). External surface shall be spray painted with approved paint over a coat of red oxide primer and internal surface of body cooler pump and motor shall be painted with two coat of bituminous paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge Make:- SYMPHONY, KHAITAN , KENSTAR, Khaitan
M&L for servicing, repair of Voltage stabilizer of capacity 4/ 5 KVA cleaning , dusting, brushing, checking and rectify electrical conections, and other components complete all as specified and directed by Engineer-in-Charge
S&F in repairs time delay relay suitable for 4/5 KVA voltage stabilizer complete all as specified and directed by Engineer-in-Charge
S&F in repirs diode suitable for voltage stabilizer of capacity 4/ 5 KVA complete all as specified and directed by Engineer-in-Charge
S&F in repairs condenser suitable for voltage stabilizer of capacity 4/5 KVA complete all as specified and directed by Engineer-in-Charge
S&F electronic circuit board with relay suitable for 4/5 KVA voltage stabilizer of any make and testing complete all as directed by Engineer-in-Charge
M&L in repair transformer suitable for voltage stablizer 4/5 KVA as required on site complete all as specified and directed by Engineer-in-Charge
M&L for servicing,Taking down ceiling fan 56"/48" sweep removing cleaning of dust, properly cleaning greasing of bearing including replacing and painting connecting up complete all as specified and directed by Engineer-in-Charge
Supply and fixing capacitor, capacity 2.5 mfd in replacement complete all as specified and directed by Engineer-in-Charge
Supply and fixing capacitor, capacity 3.15 mfd in replacement complete all as specified and directed by Engineer-in-Charge
M&L for rewinding of burnt ceiling fan motor 1200/1400 mm sweep with super enamelled copper winding wire of suitable guage as per details of any make /model complete all as specified and directed by Engineer-in-Charge
Supply and replacement of ball bearing of ceiling fan of any size complete all as specified and directed by Engineer-in-Charge
Supply and fixing and connecting flexible copper twisted twin core of size 23/00076 complete all as specified and directed by Engineer-in-Charge Make:- L&T, FINOLEX, GRANDLAY, HAVELLS, POLYCAB
M & L Painting of Ceiling fan 48" size complete in size with super enameled synthetic paint by spraying including filling cavities and complete removing of old paint etc complete all as specified and directed by Engineer-in-Charge
Supply and replacement of gun metal bush of any type/make/size complete all as specified and directed by Engineer-in-Charge
supply and replacement of rubber real complete all as specified and directed by Engineer-in-Charge
Supply and replacement of U Clamp complete with nuts, bolts, pins. Heavy duty complete all as specified and directed by Engineer-in-Charge
Supply and fixing nuts,bolts, washers and spilt pins for ceiling fan complete all as specified and directed by Engineer-in-Charge
Supply and replace spring washers for fan blades complete all as specified and directed by Engineer-in-Charge
M&L for servicing of wall mounting fan motor 400 mm sweep with super enamelled copper winding wire of suitable guage as per details details of any make /model complete all as specified and directed by Engineer-in-Charge
S&F wall mounting fan motor for 400 mm sweep complete all as specified and directed by Engineer-in-Charge
S&F wall mounting fan blade for 400 mm sweep complete all as specified and directed by Engineer-in-Charge
M&L for servicing of Exhaust fan of any size complete all as specified and directed by Engineer-in-Charge
S&F Exhaust fan 10"/12" sweep complete all as specified and directed by Engineer-in-Charge
S&F PVC Exhaust fan 300MM sweep complete all as specified and directed by Engineer-in-Charge
M&L for Exhaust fan motor for 300 mm sweep complete all as specified and directed by Engineer-in-Charge
M&L for Exhaust fan blade for 300 mm sweep complete all as specified and directed by Engineer-in-Charge
S & F Heating element 3 KW with thermostat for electrical Back up suitable of solar geyser as existing model complete all as specified and directed by Engineer-in-Charge
S & F in Replacement of heating element suitable for geysers any type as site requirement ISI mark complete all as specified and directed by Engineer-in-Charge.(a) 2.00 KW Capacity 230 Volts
All as per item No 89 above but (b) 1.50 KW Capacity 230 Volts complete all as specified and directed by Engineer-in-Charge
S & F in replacement thermostat switch any type suitable for geyser of any size/model complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exc 1.5m wide and not exc 1.5M depth for laying of GI/CI pipe lines etc getting out including forming bottom surface to required level and gradient in Soft Loose soil complete all as specified and directed by Engineer-in-Charge
Returning and filling in excavated soil including spreading leveling, watering, well ramming in layers not exc 25 Cm thick complete all as specified and directed by Engineer-in-Charge
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge
Supply and lay steel water tubing GI medium grade ISI marked with all fittings laid in trenches or fixed to wall etc complete for 20 mm dia bore sizes complete all as specified and directed by Engineer-in-Charge:-
All as per item No 95 but 25mm dia bore complete all as specified and directed by Engineer-in-Charge
All as per item No 95 but 50mm dia bore complete all as specified and directed by Engineer-in-Charge
All as per item No 95 but 80mm dia bore complete all as specified and directed by Engineer-in-Charge
Supply and fix connected Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves:- 20 mm dia bore complete all as specified and directed by Engineer-in-Charge
All as per item No 99 but 25mm dia bore complete all as specified and directed by Engineer-in-Charge
All as per item No 99 but 50mm dia bore complete all as specified and directed by Engineer-in-Charge
Taking out/burning out of leaking and damaged lead joints of the existing CI mains from the position including removing the old lead carefully with out damaging to the pipe complete for the following bore of pipes complete all as specified and directed by Engineer-in-Charge (Note :- Excavation and earth work will be measured and paid separately ):- 80 mm bore
All as per item No 102 but 100 mm bore complete all as specified and directed by Engineer-in-Charge
All as per item No 102 but 150 mm bore complete all as specified and directed by Engineer-in-Charge
M&L for DI Pipe fitting (Tee,bends any type,radius and angle) tapers any type ( straight,bend,increasing, decreasing or double sockets etc.) junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of all size dia DI pipe complete all as specified and directed by Engineer-in-Charge
Supply and lay pipe ductile Iron , S/S including specials, Class “K-7” ,150 mm (6”) dia bore ISI marked with all fittings laid in trenches or fixed to wall etc complete all as specified and directed by Engineer-in-Charge Make : ELECTO-STEEL/LANCO,SRIKALAHASTHI,JINDAL,KESORAM,ELECTROTHERM,TATA METALIKS, TATA KUBOTA
Supply and lay pipe ductile Iron , S/S including specials, Class “K-7” ,200 mm (8”) dia bore ISI marked with all fittings laid in trenches or fixed to wall etc complete all as specified and directed by Engineer-in-Charge Make : ELECTO-STEEL/LANCO,SRIKALAHASTHI,JINDAL,KESORAM,ELECTROTHERM,TATA METALIKS, TATA KUBOTA
M & L for replacement of Submersible cable flat PVC insulated Sheathed copper Conductor 10 sqmm 3 Core complete all as specified and directed by Engineer-in-Charge
M&L for Cutting the CI / DI pipes and reducing the required length before laying for inserting of new CI specials such as Tees/Reducers/Tail pieces/collers/sluice valve/Air release valve etc complete for the following complete all as specified and directed by Engineer-in-Charge (Note :- CI specials and earth work will be measured and paid seperately) 80 mm dia
All as per item No 109 but 100 mm dia complete all as specified and directed by Engineer-in-Charge
All as per item No 109 but 150 mm dia complete all as specified and directed by Engineer-in-Charge
Material and labour for run lead joints including jointing materials such as spun yarn etc complete for the sizes 80 mm bore complete all as specified and directed by Engineer-in-Charge
All as per item No 112 but 100 mm bore complete all as specified and directed by Engineer-in-Charge
All as per item No 112 but 150 mm bore complete all as specified and directed by Engineer-in-Charge
Material and labour for joints for 80 mm bore with fibre board or rubber gasket including jointing materials such bolts, nuts washers and white lead or mineral oil etc complete all as specified and directed by Engineer-in-Charge
All as per item No 115 but 100 mm bore complete all as specified and directed by Engineer-in-Charge
All as per item No 115 but 150 mm bore complete all as specified and directed by Engineer-in-Charge
Material and labour for CI specials such as bends, tees, collars, tail pieces flanges etc complete suitable for CI mains of sizes upto 150mm complete all as specified and directed by Engineer-in-Charge
M&L for Repairs to sluice valves for 80 mm bore such as replacement of unsv/warnout gland on stuffing box, rubber gasket of suitable size, filling or grinding to gate, cleaning inside gate valve properly and remove sand and other waste materials, replacement of warned out nut/bolts with washers, CI gland cover with nut bolts including testing of leakage complete all as specified and directed by Engineer-in-Charge
All as per item No 119 but 100 mm bore complete all as specified and directed by Engineer-in-Charge
All as per item No 119 but 150 mm bore complete all as specified and directed by Engineer-in-Charge
M&L for Disconnection and removing the unsv/broken spindle from the sluice valve after opening the nut and bolts and replace the same with new spindle made with brass of same size and length and turns including with necessary fixing arrangements, testing and commissioning complete for 80 mm bore sizes complete all as specified and directed by Engineer-in-Charge
All as per item No 122 but 100 mm bore complete all as specified and directed by Engineer-in-Charge
All as per item No 122 but 150 mm bore complete all as specified and directed by Engineer-in-Charge
M&L for replacement of dosing pump complete all as specified and directed by Engineer-in-Charge
M&L for Preparation of surface and painting to sluice valves of any size incl hand wheel in position complete with black synthetic enamel paint one coat complete all as specified and directed by Engineer-in-Charge
S&F cast iron sluice valve with flanged ends, confirming to IS-780 type PN-1.6 cast iron body with CI wheel brass spindle, joints with rubber gaskets including bolts nuts and washers complete with ISI mark size 150 mm CI line in position, complete all as specified and directed by Engineer-in-Charge
All as per item item No 127 but 100 mm dia complete all as specified and directed by Engineer-in-Charge
All as per item item No 127 but 80 mm dia complete all as specified and directed by Engineer-in-Charge
Supply only calcium Hypo Chlorite 65% to 70% chlorine content in Granular and tablet form for Chlorination of water complete all as specified and directed by Engineer-in-Charge Make :- "Puri Chlor"
S&F Water level Indicator for over head tank, water level display wired sensor security system with alaram system having power input 230V, 50 Hz, including electrical cable complete all as specified and directed by Engineer-in-Charge
S&F Foot valve of size 80mm suction pipe complete all as specified and directed by Engineer-in-Charge
Material and labour for painting of Surfaces plain or moulded, n exc 10cm width or girth when unconnected with other painting or when painted in a different tintCI pipes up to 150 mm dia & its accessories in installation/over head tanks complete all as specified and directed by Engineer-in-Charge
Material and labour for Distempering walls with distemper dry, white or tinted with distemper oilemulsion complete all as specified and directed by Engineer-in-Charge
Material and labour for Distempering walls with distemper dry, white or tinted with cement paint complete all as specified and directed by Engineer-in-Charge
M & L for Dismantling and strip opening of burnt Booster pump motor of capacity upto 12.5 HP including cuttting removing burnt winding wire from stator assembly and preparing slots , rewinding the same with super enamled water proof copper winding wire of suitable gauge with necessary insulation materials varnising etc and reassembling stator rotor assembly with pump testing, commmisioning complete all as specified and directed by Engineer in Charge
Material and labour for lifting /Lowering of Submersible Pump Set of any capacity for repair/ Overhauling /rewinding etc with man power/Chain Pulley arrangement including shifting to local workshop for repair and to bring back after repair at site including testing for smooth functioning of complete all as specified and directed by Engineer in Charge.
M & L for Dismantling and strip opening of burnt submersible pump of capacity 10 HP to 15 HP including cuttting removing burnt winding wire from stator assembly and preparing slots , rewinding the same with super enamled water proof copper winding wire of suitable gauge with necessary insulation materials varnising etc and reassembling stator rotor assembly with pump testing for smooth functioning of rated dilivery with Bearing Bush gun metal -04 Nos (ii) Rotor Sleeve stainless steel -01 Nos (iii) Water seal -02 Nos (iv) housing CI -02 Nos(v) Thrust bearing block -02 Nos (vi) Thrust Plate- 02 Nos parts complete all as specified and directed by Engineer in Charge
Supply and fixing of in replacement of DOL starter 5 HP 3 phase 415 volts for submersible pumps all as specified and directed by Engineer-in-charge. Make:- SIEMENS, L&T, ABB, LEGRAND
S & F submersible pump controller fully automatic star delta starter with sheet metal enclosure Type suitable for motor rating 15 HP 415 V 3 Ph relay range 28 -42 Amps complete all as specified and directed by Engineer-in-Charge Make:- SIEMENS, L&T, ABB, LEGRAND
Supply and fixing of in replacement of cosmic star delta motor starter 12.5 HP 3 phase 415 volts for Booster pumps complete all as specified and directed by Engineer-in-Charge Make:- SIEMENS, L&T, ABB, LEGRAND
Supply and fixing of in replacement of contactor set complete for Submersible pump 15 HP acomplete all as specified and directed by Engineer-in-Charge Make:- SIEMENS, L&T, ABB, LEGRAND
Supply and fixing of in replacement of contactor coil for Submersible pump 15 HP complete all as specified and directed by Engineer-in-Charge Make:- SIEMENS, L&T, ABB, LEGRAND
Supply and fixing of in replacement of Protection relay for Submersible pump 15 HPcomplete all as specified and directed by Engineer-in-Charge Make:- SIEMENS, L&T, ABB, LEGRAND
M&L for replacement of unservicable CI non return valve type IS 5312 flanged ends 100 mm dia complete all as specified and directed by Engineer-in-Charge
M&L for replacement of unservicable CI non return valve type IS 5312 flanged ends 150 mm dia complete all as specified and directed by Engineer-in-Charge
M&L for chemical and bacteriological analysis of Raw water collected from all the pump house situated in AF stn Dadri complete all as specified and directed by Engineer-in-Charge
M&L for chemical and bacteriological analysis of chlorinated water collected from distribution line PH NO 1 situated in AF stn Dadri complete all as specified and directed by Engineer-in-Charge
M&L for dismantling and taking down mono block booster pumps/Non clogging sewage pump up to 5HP motor for repair/overhauling including disconnecting, transporting to local workshop for repair/reassembling the same after replacing following work out spares including alignment and replacement of foundation bolts and necy civil works like plastering brick work, PCC for foundation:(i) Replacement of pump bearing (as per sample)-02 nos (ii) repair /straighteing of Pump shaft. (iii) Replacement of glands/nuts/bolts -01nos. (iv) replacement of shaft key -01 nos.( v) repalcemnt of Pump Impeller complete all as specified and directed by Engineer-in-Charge
M/S Anand Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .