Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.9 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹72.7 L+₹97,471 (1.36%)Rejected-AOC 128 CANTT ROAD GARHA JALANDHAR PUNJAB 144001 | JALANDHAR | JALANDHAR | PUNJAB | 144001 | L2 | Rejected-AOC R | |
| 3 | L3₹77.0 L+₹5.2 L (7.31%)Rejected-AOC | L3 | Rejected-AOC R |
Tender Value
₹80.5 L
EMD Value
₹1.5 L
Closing Date
13 May 2023, 6:00 pmClosed
HQ CWE (AF) LEH
HQ CWE (AF) LEH
SPECIAL REPAIR TO OFFICER ACCOMODATION AT AIR FORCE STATION LEH
2023_MES_588515_1
81155/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) LEH
As per Tender Documents
7 documents required · 7 mandatory
₹1,000
GE (AF) LEH
₹1.5 L
Yes
7 Aug 2023
6 Apr 2023
15 May 2023
6 Apr 2023
13 May 2023
28 Apr 2023
Amount
PART-I B/R WORKS Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth and not exceeding 10Sqm on plan and getting out in any type of soil, trimming sides, leveling bottom, watering and well ramming bottom, complete all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in hard/dense soil complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc., complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) of area not exceeding 1.5Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) of area exceeding 1.5Sqm but not exceeding 4.0Sqm each complete all as specified and directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Material and labour, Plain Cement Concrete (1:2:4) type B-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
Material and Labour for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240, complete all as specified and directed.
Material and Labour for Rolled mild steel in Joist, channel, angle, or tee sections,hollow square/rectangular tubes fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe 410-W(Gde-E- 250) quality-A, complete all as specified and directed.
Material and Labour for Rolled mild steel in main and cross beams, hip and jack rafters; purlins hollow square/rectangular tubeswhere connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting platesconforming to Fe 410-W(Gde-E- 250) quality-A, complete all as specified and directed.
Material and Labour for Rolled mild steel in any kind channel, angle, or tee sections,hollow square/rectangular tubes as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc.conforming to Fe 410-W(Gde-E- 250) quality-A, complete all as specified and directed.
Material and Labour for 0.50mm thick Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed.
Material and Labour for 0.50mm thick Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed.
Material and labour, Plain Cement Concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) or flat, rough finished, complete all as specified and directed.
Supply and fix in position, mild steel bars TMT, 10mm dia and over, cut to length, bent to shape required, including cranking, bending for hooping of columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, as in reinforcement, complete all as specified and directed.
Supply and fix in position, mild steel bars TMT, 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Material and labour, reinforced cement concrete M-20 (Nominal mix Mix) using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed. Note : Steel reinforcement bars and use and waste of form work shall be measured and paid separately.
Material and labour, pre-cast cement concrete block masonry with soild blocks type C-1, 1:3:6 (20mm graded stone aggregate), exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
Material and labour, 40mm thick cement concrete (1:2:4) type B-1 using 20 graded crushed stone aggregate as in flooring,finished surface even and fair without using extra cement complete all as specified and directed.
Material and labour, 25mm thick cement concrete (1:2:4) type B-0 using 12.50 graded crushed stone aggregate as in flooring,finished surface even and fair without using extra cement complete all as specified and directed.
Material and labour, 100mm thick cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in subbase of flooring, complete all as specified and directed.
Material and labour, first quality non-skid coloured ceramic tiles 7 - 8mm thick, area of each tile exceeding 0.06Sqm but not exceeding 0.11Sqm, in floors etc. set and jointed in neat cement slurry @ 3kg/sqm over and including 15mm thick screed bed/bedding layer in cement mortar (1:4), and pointed in white cement mixed with pigment or coloured cement to match, complete all as specified and directed.
Material and labour, first quality glazed ceramic designer pattern coloured tiles 350mmx250mm x 7mm/ 450mmx350mm x 7mm thick in vertical surfaces as in dado, set and jointed in neat cement slurry @ 3Kg/Sqm and pointed in white cement mixed with pigment or coloured cement to match the shade of tiles (fixed in pattern of combination of dark and light colour with border), over and including 10mm thick rendering in CM (1:3) as backing coat, finished fair and even to receive tiles, complete all as specified and directed.
Supply & Fix in repair for HDF based laminated wooden flooring of planks of size 1.20mx 0.198x 8mm thick non glue laminated flooring including 0.60mm PE poly moisture foam as in underlay barrier of over lapping 20 cm fix them with adhesive tape,boarding fixing floating manner based tongue and groove interlocking arrangement including taking out old wooden flooring complete all as specified and directed. Note;- Colour and design as approved by GE
Material and labour, 60mm thick PUF panels in wall with 0.5mm thick prepainted (colour approved by GE) galvalums sheet on both face/side including all fixing arrangements such as bottom GI channel for holding panel at base, or screws to hold the panels with frames, 0.50mm thick flashing making a lap of minimum 50mm at all junctions of walls and ceiling and at corners and all doors and windows openings secured with screws and fasteners as per manufacturer's instructions as in replacement of old damaged portion of wall panelling, complete all as specified and directed.
Material and labour, 40mm thick PUF panels in ceiling with 0.5mm thick prepainted (colour approved by GE) galvalums sheet on both face/side including all fixing arrangements such as screws or fasteners to hold the panels with frames, as per manufacturer's instructions as in replacement of old damaged portion of ceiling panel, complete all as specified and directed.
Material and labour, door shutters with and including chowakhts as per manufacturer,s specifications and instructions of 60mm thick PUF panels with 0.5mm thick prepainted (colour approved by GE) MS sheet on both side including 200 mm long aluminium anodised tower bolt-02Nos, aluminium anodised sliding door bolt of 300mm long-01No, built in locking arrangement (mortice lock with handle) and 150mm long aluminium anodised handle-02Nos fixed with 100mm long heavy duty stainless steel butt hinges-03Nos , fixed with necessary fixing arrangements with existing structure by means of fasteners, screws and necessary welded joints as per manufacturer's instructions , complete all as specified and directed.
Material and labour, rendering 15mm thick plaster in cement mortar (1:4), on brick/concrete surfaces of walls, finished even and smooth without using extra cement, complete all as specified and directed.
Material and labour, rendering 15mm thick plaster in cement mortar (1:6), on brick/concrete surfaces of walls, finished even and smooth without using extra cement, complete all as specified and directed.
Material and labour, two coats of cement base cement base paint over a coat of alkali resistant primer including preparation of plastered/ concrete surfaces, complete all as specified and directed.
Material and labour, for two coat of oil emulsion distemper over a coat of primer incl preparation of newly plastered wall surfaces complete all as specified and directed.
Material and labour, preparation of new steel surfaces of any description, not otherwise described, over 10cm width or girth, applying two coats of synthetic enamel paint over and including one coat of red oxide primer, complete all as specified and directed.
Material and labour,Powder coated (colour aproved by GE) Anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
Material and labour,Powder coated (colour aproved by GE) Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1-No.). hinges type B-21100mm long (2-No.) suitable handle (1-No.) complete all as specified and directed. Note:- Contractor quoted rates are inclusive for providing double glass fixing channel in glazed window only wherever directed by GE. Glass and wire gauze shall be measued and paid seperately.
Supply and fixing, 4.8mm Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
Supply and fixing, 4.8mm Sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed.
Supply and fixing, Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staplescomplete all as specified and directed.
Material and labour,3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes 25mm outer dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc.including taking down old steel pipe of 15mm dia complete all as specified and directed.
Supply and fix in repair, Vitreous China wash down water closet pan (pedestal pattern) white(excluding fixing bolts,) incl 10 ltrs capacity, PVC valveless, symphonic type flushing cistern, Iow level, white, with inlet, ball valve, float and handie including brackets and provision of Flush or high density or PVC ,32mm dia for low level cistern pipe of polythene complete all as specified and directed.
Supply and fix in repair, Vitreous china wash basin, white,fiat back, size 550 X 450 mm with pedestal including 15mm bore brass CP mixer for mixing hot and cold water including PVC waste pipe 32 mm dia with waste fitting brass chromium plated with long screwed shanks and fly nuts,complete all as specified and directed.
Supply & fix in repair, PVC connections of PTMT, non corrosive, with nuts & washers on both ends, 450mm long, suitable for 15mm dia bore pipe, complete all as specified and directed.
Supply and fix in repair, bib taps, cast copper alloy, fancy type, chromium plated, screwed down high pressure, screwed for iron pipe or for brass ferrule 15mm dia bore, complete all as specified and directed.
Supply and fix in repair, stop valves, fancy type chromium plated , cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes 15mm bore iron pipe or for brass ferrulee complete all as specified and directed.
Supply and fix in repair, brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges with and including screws complete all as specified and directed.
Supply and fix in repair, Toilet paper holder with flat recessed type, stainless steel complete all as specified and directed.
Supply and fix in repair, Health faucet (ABS body) mild steel chromium plated for 15mm dia bore pipe with 1.25 metres long flexibke tube and ABS wall hook including making connection complete all as specified and directed.
Material and labour, PVC(SWR) pipes 110mm dia, single socked, in any length with rubber ring laid in trenches, including demolition/breaking of old pipe of any nature/dia complete all as specified and directed.
Material and labour, PVC(SWR) pipes 75mm dia, single socked, in any length with rubber ring laid in trenches, including demolition/breaking of old pipe of any nature/dia complete all as specified and directed.
Supply and fix in repair, 75mm dia outlet PVC (SWR) floor trap, plain with grating including jointing to waste pipe with solvent cement , complete all as specified and directed.
Supply and fix in repair, 110mm dia PVC (SWR) bend of any radius, complete all as specified and directed.
Material and labour, RCC pipes 150mm dia, class NP2, laid on concrete bed and jointed in cement sand mortar (1:1), and tested, including demolition/breaking of old pipe of any nature complete all as specified and directed. Note : Concrete bed, haunching etc, shall be measured and paid separately.
Material and labour, concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete (1:3:6) type C-2, size of pipe 150mm dia bore, complete all as specified and directed.
PART-II E/M WORKS Material and labour for point wiring for one light/fan /bell point controlled by one switch one way in and including PVC conduit or cassing capping as per site requirement using FRLS PVC unsheathed multi strand copper conductor cable 1.5sqmm single core for one light/fan point/ bell point controlled by one switch including 3mm thick plastic laminated sheet cover over PVC/wooden box for earth continuity insulated PVC unsheathed (green colour) 1.5sqmm copper earth wire connected to common earth duly using complete all as specified and directed . Note : (a) wiring shall be done by using proper colour coding.
All as per item No 60 here-in-above but for 05 Amp socket outlet on independent board
All as per item No 60 here-in-above but using 2.5 sqmm wire for phase neutral and earth for 15 Amps independent socket outlet
Supply and fix, socket outlet two-in-one, three pin 6 and 16Amp, flush type 230 volts complete all as specified and directed .
Supply and fix, socket outlet two-in-one, three pin 6 Amp, flush type 230 volts complete all as specified and directed .
Supply and fix, LED adore lamp 9/10Watt, B22 base 6500k CDL typecomplete all as specified and directed
Supply and fix, Crystal glass LED tube light of 18W T8 , 2700 k ,4ft. (double side connection with LED driver) with very high efficency suited for installation in existing tubelight G13 lamp holders to give glare free light complete all as specified and directed
Supply and fix, Energy saving new generation Endura Rugby Neo - IP65, 10W LED IP65 bulkhead luminaire with opal diffuser, etc complete with all accessories rewired electrically connected in and including taking down of old unservicable fitting, complete all as specified and direcred.
Supply and fix, Switch piano, flush type 5 Amps, one way 230 volts complete all as specified and direcred.
Supply and fix, ceiling rose Bakelite white/black coloured of size 25x50mm two to three terminals, complete all as specified and as directed.
Supply and fix, Lamp holder insulated bodywith back plate for batten fitting suitable for LED lamp complete all as specified and directed
Supply and fix, Distribution box Double door type , SPN 8 way,with 200 Amps rated bus bar, 240 Volts for MCBs, grouted flush to walls complete with IP 43 and metal double door ,epoxy powder coating and including taking down of old unservicable main switches /Distribution board including fuses MCBs after removing all connection and making good the disturb surfaces complete all as specified and directed
Supply and fix, MCB SPN 32 Amp, 240 volt-10KA complete all as specified and directed
Supply and fix, MCB SP 6 to 32 Amp, 240 volt-10KA complete all as specified and directed
Supply and fixing, bell push ,flush type,single pole 5 amps , complete all as specified and as directed.
Supply and fixing, bell ding-dong type, AC, 230Volt , complete all as specified and as directed.
Supply and fix, Single Pole and Neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed
Material and labour, sub main wiring with two single core 4Sqmm (nominal area) PVC insulated and unsheathed cables with stranded copper conductor FRLS, drawn in and including PVC cassing capping with all standard accessories including one run of continuous PVC insulated stranded copper conductor FRLS cable 4Sqmm (nominal area) for earth continuity, complete all as specified and directed. Note(s) :- 3runs of 4Sqmm main cable and 01 run of cassing capping shall be measured as one unit/one Running Metre.
Supply and fix, Water heater storage type, 25 litres capacity, 5star rating, electric including grouting holding down bolts etc., complete all as specified and directed.
Supply and fix, 250mm sweep exhaust fan made of strudy engineering plastic with louvers shutters, 230volt, 50HZ, 1200 RPM, copper winding complete all as specified and directed.
Supply and fix, wall mounting fan, 400 mm sweep, heavy duty, AC single phase, 230 volts including connection with 0.5 sqmm multistranded copper conductor flexible wire from ceiling rose, necessary fixing arrangement i.e anchor nut, bolt, washer and grouting and making good to disturbed surface complete all as specified and directed.
Supply and fix, 15mm bore Steel water tubing medium grade galvanised ( ISI marked) with all fittings( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc), complete all as specified and directed.
Cutting existing steel tubing 15 mm bore for altertaions or additions ( Each cut measured ) complete all as specified and directed.
Screwing existing steel tubing 15 mm for alterations or addition complete all as specified and directed.
Supply and fix, 40mm bore Steel water tubing medium grade galvanised ( ISI marked) with all fittings( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc), complete all as specified and directed.
Supply and fix, 20mm bore Steel water tubing medium grade galvanised ( ISI marked) with all fittings( such as bends elbows, Tee, short pieces, connectors back nuts, diminishing pieces, caps and plug, unions etc), complete all as specified and directed.
Supply and fix gun metal, gate valves of 20mm dia , with iron wheel head, screwed both ends for GI pipecomplete all as specified and directed.
Supply and fix gun metal, gate valves of 40mm dia , with iron wheel head, screwed both ends for GI pipecomplete all as specified and directed.
Supply and fixing/hoisting, rotational moulded polyethylene (HDPE) water storage tanks (cylindrical vertical with closed top), 500litres capacity ‘triple layered’, white colour with screwable lid, hoisted and fixed in position including inlet, outlet and drain pipe with plug, ball valves high pressure of PTMT (Minimum weight 210gms) with epoxy coated Aluminium rod & high-density plastic ball, screwed for iron pipe 20mm dia bore, complete all as specified and directed.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16Sqmm 2core aluminum conductor 1100volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note(s): Excavation & earth work, sand cushioning and PCC cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 50Sqmm 3.50core aluminum conductor 1100volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note(s): Excavation & earth work, sand cushioning and PCC cover for protection of cable shall be measured and paid separately.
Supply install, testing and commissioning of LT Feeder Pillar / Panel board cubical type outdoor Confirming to IS 8623 Part 1 1993, free floor standing / wall mounting factory fabricated made out of 3.15 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming and Outgoing MCCB, MCB and TPN Aluminum bus bars of rating not less than1.5 times the rated cap of incomer Outgoing MCCB / ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50 x 50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar . The incoming as well as Outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coded sleeves. The cubicle shall have a bottom channel of size as designed by the manufacturer's . A deteachable predrilled gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP65 degree of protection , complete as specified and consisting the following switchgears and accessories;- (a) Bus bar electrolytic grade aluminum strip with heat shrikable sleeves with colour code supported on epoxy resin based insulators, 4 strips of suitable length for current rating 250 amps.(b) Main Incoming MCCB four pole 415 V AC, current rating 100 amps, breaking cap 25 KA at 415 volts-01 No (c) Outgoing MCCB four pole 415 V AC, current rating 63 amps,breaking cap 25 KA at 415 V AC = 02Nos (d) Outgoing MCB DP 415 V AC, current rating 40 amps,breaking cap 25 KA at 415 V AC = 04 Nos (e) LED Multifunction meter flush panel mounting 96x96 mm,having parameters such as V,A,F,PF,KW,KVA,KVAR,KWH,KVAR,neutral currant, (f) LED indicator (R,Y,B) of suitable capacity (g) Complete wiring of the panel board with FRLS PVC insulated multistrand copper conductor cables of suitable current carrying capacity, end terminated with lugs and bolts, nuts and washers of galvanised iron. (h) Current transformer (Bar primary low tension) type CBF-0.6-D1 Ratio 300/5 amps, 15 VA accuracy class - 1 (j) Installing,commissioning ,testing,earth work PCC etc.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.
Material and labour, Earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to G I earth strip of 4mm dia G I wire by means of brass bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1, reinforced XPM of weight not less than 4 kg/ Sq.m and MS frame etc. including taking down of old unserviceable earthing, complete all as specified and as directed by Engineer-in-Charge. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
Note : Schedule of credit for Rs. 287378.00 (Rupees Two lakh eighty seven thousand three hundred and seventy eight only) to be deducted on acceptance of bid.
D S constructions
M/S KOHINOOR METAL
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .