Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
2 Sept 2026, 1:00 pmClosed
VDO PRASHASAK AAO AEN
Gram Panchayat Sandwa
Tubewell samagri kharid nayakon ka mohalla sandwa
2026_PRD_593395_1
G.P Sandwa /2026-27/121-125 DATE25.08.2026
Open Tender
Civil Works
Percentage
Gram Panchayat Sandwa
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Prashasak Gram Panchayat Sandwa
₹12,000
Yes
28 Sept 2026
27 Aug 2026
2 Sept 2026
27 Aug 2026
2 Sept 2026
27 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & Installation of 3 phase ISI marked submersible motor pump
set of five star rating by BEE and as per JS: 8034-2011 (pump) and IS
9283-2013 (motor) or amended up to date of approved make of
following duty condition with required accessories including making
connection suitable for tube well/DCB. The job includes lowering of
motor pump,installation of complete fitting & accessories, jointing of
electrical cables up to switch board, testing of submersible pump set
and interconnection up to water mains, complete in all respect. | 18.75 | kw | 5,688 | ₹1,06,650 |
| 2 | Supply and Fixing of electric control feeder panel comprising of
suitable rating MCCB , fully automatic star-delta starter, over load
relay, ampere meter with CTs, volt meter, phase preventor, suitable
starting capacitors,phase indicators, lighting arrangement etc complete
suitable for threephase pump set. The panel should have space for
energy meter (supplied by DISCOM). All these equipments shall be
housed by panel box made out from 18 guage M.S. Sheet with powder
coating. Panel should be of minimum size 900 x 600 x 450 mm with
Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed
with enclosure box having 4 legs,each leg's length 18" and double door
including in built locking system.The legs should be embedded in M15 cement concrete plat form.The size of CC plateform should be
equal or bigger than the base size of panel having height of at least 200
mm from ground level. The panel should have opening of suitable size
in front of space for energy meter with glass for meter reading. The
operation of panel should be Suitable for on 440 Volt AC Supply | 1 | eack | 35,437.5 | ₹35,437.5 |
| 3 | Supply & Fixing of ISI marked three core PVC flat submersible cable
as per IS 694: 1990 or amended up to date and conductor as per class 5
of IS 8130: 1980 includ ing making connection etc. 3 core 10.0 mm2 | 610 | mtr | 435.6 | ₹2,65,716 |
| 4 | Providing & Lowering in tubewell ISl marked GI Pipe "B" class as per
IS: 1239 or amended up to date threaded and double flanged (welded)
on both ends and two number 25x3mm flat welded on both ends
between pipe & flange, rubber washer & nut bolts etc. complete in all
respect | 300 | mtr | 610.2 | ₹1,83,060 |
| 5 | Providing & Fixing of double flanged, Cl body, ISi marked NR V of
approved make of following sizes | 1 | eack | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.16 MB
1.pdf
Tender Documents • 3.14 MB
BOQ_1053200.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .