Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.3 LAccepted-AOC | L1 | Accepted-AOC Quoted Lowest Rates | |
| 2 | L2₹20.1 L+₹1.6 L (8.36%)Rejected-Finance 186 B DIAMOND HARBOUR ROAD KOLKATA 700 060 | KOLKATA | WEST BENGAL | 700060 | L2 | Rejected-Finance Quoted Higher Rates | |
| 3 | L3₹20.7 L+₹2.1 L (11.4%)Rejected-Finance 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | L3 | Rejected-Finance Quoted Higher Rates | |
| 4 | L4₹21.1 L+₹2.5 L (13.4%)Rejected-Finance | L4 | Rejected-Finance Quoted Higher Rates | |
| 5 | L5₹21.4 L+₹2.8 L (15.1%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L5 | Rejected-Finance Quoted Higher Rates |
Tender Value
Refer Docs
EMD Value
₹36,400
Closing Date
14 Jan 2021, 6:00 pmClosed
MAJ SWAPNESH KOLI GE I CG P KOLKATA
DAMODAR COMPLEX GARDEN REACH ROAD KOLKATA 23
REPAIR/ REPLACEMENT OF EXTERNAL WATER SUPPLY INCLUDING REPAIRING OF PUMP, MOTORS AND ALLIED WORKS AND MAINTENANCE AND REPAIRS TO OLD UNSERVICEABLE EXTERNAL STREET LIGHT FITTINGS INCLUDING ALLIED E/M WORKS AT NAVY AREA UNDER GE (I) (CGP) KOLKATA
2020_MES_405816_2
8889/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
KOLKATA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE I CG P KOLKATA
₹36,400
Yes
5 Feb 2021
8 Jan 2021
16 Jan 2021
8 Jan 2021
14 Jan 2021
8 Jan 2021
Amount
Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pire holes, etc. n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated soil not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soil complete all as specified and as directed.
Taking up or down 20 mm bore steel water tubing and connections including cleaning for refixing or removal complete all as specified and directed.
S&F 20 mm dia steel water tube medium grade galvanised with all fittings and fixed complete to walls, ceiling, floors, trenches complete all as specified and directed.
Taking up or down 25 mm bore steel water tubing and connections including cleaning for refixing or removal all as specified and directed.
S&F 25 mm dia steel water tube medium grade galvanised with all fittings and fixed complete to walls, ceiling, floors, trenches complete all as specified and directed.
Taking up or down 40 mm bore steel water tubing and connections including cleaning for refixing or removal all as specified and directed.
S&F 40 mm dia steel water tube medium grade galvanised with all fittings and fixed complete to walls, ceiling, floors, trenches complete all as specified and directed.
Taking up or down 50 mm bore steel water tubing and connections including cleaning for refixing or removal all as specified and directed.
S&F 50 mm dia steel water tube medium grade galvanised with all fittings and fixed complete towalls, ceiling, floors, trenches complete all as specified and directed.
Taking up or down 80 mm bore steel water tubing and connections including cleaning for refixing or removal all as specified and directed.
S&F 80 mm dia steel water tube medium grade galvanised with all fittings and fixed complete to walls, ceiling, floors, trenches complete all as specified and directed.
Taking up or down 100 mm bore steel water tubing and connections including cleaning for refixing or removal all as specified and directed.
S&F 100 mm dia steel water tube medium grade galvanised with all fittings and fixed complete to walls, ceiling, floors, trenches complete all as specified and directed.
S&F 20 mm dia gun metal gate valve with iron wheel head screwed both ends for iron pipes and fixed in existing position including taking down old one complete all as specified and as directed.
S&F 25 mm dia gun metal gate valve with iron wheel head screwed both ends for iron pipes and fixed in existing position including taking down old one complete all as specified and as directed.
S&F 40 mm dia gun metal gate valve with iron wheel head screwed both ends for iron pipes and fixed in existing position including taking down old one complete all as specified and as directed.
S&F 50 mm dia gun metal gate valve with iron wheel head screwed both ends for iron pipes and fixed in existing position including taking down old one complete all as specified and as directed.
M&L CI diaphargm valve flanged conforming to IS of size 20 mm bore 10 kgf/cm2, 1.0Mpa class-5 including necessary nuts bolt, washer, rubber/fibre board gasket complete all as specified and directed including taking down old one.
M&L CI diaphargm valve flanged conforming to IS of size 25 mm bore 10 kgf/cm2, 1.0Mpa class-5 including necessary nuts bolt, washer, rubber/fibre board gasket complete all as specified and directed including taking down old one.
M&L CI diaphargm valve flanged conforming to IS of size 50 mm bore 10 kgf/cm2, 1.0Mpa class-5 including necessary nuts bolt, washer, rubber/fibre board gasket complete all as specified and directed including taking down old one.
M&L CI diaphargm valve flanged conforming to IS of size 80 mm bore 10 kgf/cm2, 1.0Mpa class-5 including necessary nuts bolt, washer, rubber/fibre board gasket complete all as specified and directed including taking down old one.
M&L CI diaphargm valve flanged conforming to IS of size 100 mm bore 10 kgf/cm2, 1.0Mpa class-5 including necessary nuts bolt, washer, rubber/fibre board gasket complete all as specified and directed including taking down old one.
M&L UPVC diaphargm valve flanged conforming to IS of size 50 mm bore 10 kgf/cm2, 1.0Mpa class-5 including necessary nuts bolt, washer, rubber/fibre board gasket complete all as specified and directed including taking down old one.
Supply only brass spindle including GM check nut suitable for 80 mm bore sluice valve.
Supply only brass spindle including GM check nut suitable for 100 mm bore sluice valve.
Supply only brass spindle including GM check nut suitable for 150 mm bore sluice valve.
Supply and fix MS column pipe 80 mm bore 3.0 m long with both end threaded with heavy duty 7.0 mm thickness sayonara socket including taking down old one complete all as specified and as directed. (Make - TATA or equivalent)
Supply and fix MS ERW column pipe 80 mm bore 3.0 m long with both end flanged type with heavy duty 7.0 mm thickness with rubber gasket including taking down old one complete all as specified and as directed. (Make - TATA or equivalent)
M&L UPVC butterfly valve both end flanged conforming to IS of size 63 mm bore 10 kgf/cm2, 1.0Mpa class-5 including necessary nuts bolt, washer, rubber/fibre board gasket complete all as specified and directed including taking down old one.
M&L UPVC butterfly valve both end flanged conforming to IS of size 110 mm bore 10 kgf/cm2, 1.0Mpa class-5 including necessary nuts bolt, washer, rubber/fibre board gasket complete all as specified and directed including taking down old one.
M&L UPVC butterfly valve both end flanged conforming to IS of size 160 mm bore 10 kgf/cm2, 1.0Mpa class-5 including necessary nuts bolt, washer, rubber/fibre board gasket complete all as specified and directed including taking down old one.
M&L for run lead joint for CI spigot and socket pipes & fittings 100 mm bore with new lead complete all as specified and as directed including burning out lead joint in position, including removing old lead complete.
M&L for run lead joint for CI spigot and socket pipes & fittings 150 mm bore with new lead complete all as specified and as directed including burning out lead joint in position, including removing old lead complete.
M&L for run lead joint for CI spigot and socket pipes & fittings 80 mm bore with new lead complete all as specified and as directed including burning out lead joint in position, including removing old lead complete.
Cutting CI water mains in position for insertions of new fittings such as Tee, bend collar etc as required complete all as specified and as directed up to 80 mm dia CI pipes.
Cutting CI water mains in position for insertions of new fittings such as Tee, bend collar etc as required complete all as specified and as directed up to 100 mm dia CI pipes.
M&L for cast iron fittings spigot and socketed pipes upto 150 mm bore, such as bend (any type radius and angle) tapers, any type (straight bend increasing decreasing or double socket etc) Tee piece single branch junction 'Y' junction, cross, double branch (all sockets and/or socket and spigot) collars caps and plugs etc complete all as specified and as directed including taking down old one.
Supply and laying in trenches 150 mm bore, cast iron pipe, flanged ends centrifugally cast (spun pipe as per IS 1536 2001), class LA, in any length laid in trenches complete all as specified and directed (Make : Electrosteel Castings Ltd / Keshoram) including taking down old one. ( Note : Jointing and excavation shall be measured and paid separately under respective items in this schedule)
Taking out existing submersible pump set of capacity upto 15 HP along with column pipe from the bore well and lowering the same after repairing the pump set including and reconnection all electric & mechanical connection. (Note (i) One lifting & one lowering shall be measured one job (ii) Repair to pumps & motor and replacement of spare parts shall be measured and paid separately. (iii) Replacement of column pipe if required shall be measured & paid separately as supply only under respective item in this Schedule)
Dismantling carefully submersible pump and taking out and replacement of locknut, impeller key, collar ring, SS coupling nuts, bolts, washer and re-assembling the pump of capacity 7.5 HP and painting the pump set with two coats of synthetic enamel paint over a coat of red oxide primer after scraping out old paint complete all as specified and directed. (Note : (i) Spare parts like Thrust bearing, Impeller, Sand Guard, Bush, Shaft, NRV if required shall be measured and paid separately under respective items in this Schedule as supply only. (ii) Winding of motor if required shall be measured and paid separately under respective item in this Schedule )
Dismantling carefully submersible pump and taking out and replacement of locknut, impeller key, collar ring, SS coupling nuts, bolts, washer and re-assembling the pump of capacity 10/12.5/15 HP and painting the pump set with two coats of synthetic enamel paint over a coat of red oxide primer after scraping out old paint complete all as specified and directed. (Note : (i) Spare parts like Thrust bearing, Impeller, Sand Guard, Bush, Shaft, NRV if required shall be measured and paid separately under respective items in this Schedule as supply only. (ii) Winding of motor if required shall be measured and paid separately under respective item in this Schedule )
M&L for rewinding of electric motor of 10 HP to 15 HP (Submersible motor) with water proof PVC coated insulation copper wire of existing gauge with taking down burnt winding, cleaning of stator and rooter including replacement of bearing etc. including testing & commissioning complete all as specified and directed.
Supply only Thrust bearing for submersible pump of capacity 7.5/10/12.5/15 HP Make Calama, KSB, CRI.
Supply only Gun Metal Impeller for submersible pump of capacity 7.5/10/12.5/15 HP Make Calama, KSB, CRI.
Supply only Sand Guard for submersible pump of capacity 7.5/10/12.5/15 HP Make Calama, KSB, CRI.
Supply only Gun Metal Bush for submersible pump of capacity 7.5/10/12.5/15 HP Make Calama, KSB, CRI.
Supply only Stainless Steel Shaft for submersible pump of capacity 7.5/10/12.5/15 HP Make Calama, KSB, CRI.
Supply only NRV for submersible pump of capacity 7.5/10/12.5/15 HP Make Calama, KSB, CRI.
Material & labour for rewinding of centrifugal pump motor 5/10/12.5/15 HP with water proof PVC coated insulation copper wire of existing gauge with taking down burnt winding,cleanining of stator and rotor including replacement of bush, bearing etc including testing & commissioning complete all as specified and directed.
M&L for rewinding of electric motor of 7.5HP to 10 HP (Submersible motor) with water proof PVC coated insulation copper wire of existing gauge with taking down burnt winding, cleaning of stator and rooter including replacement of bearing etc. including testing & commissioning complete all as specified and directed.
M&L for rewinding of electric motor of 15 HP to 25 HP(Submersible motor) with water proof PVC coated insulation copper wire of existing gauge with taking down burnt winding, cleaning of stator and rooter including replacement of bearing etc. including testing & commissioning complete all as specified and directed.
Lifting of monoblock U/S submersible pumping set of 5 HP to 10 HP capacity form semi under ground sump, open type after disconnection of electrical & mechanical connection and dismantling all the worm out parts, rewinding with water proof PVC coated insulation copper wire of existing gauge with taking down burnt winding, cleaning of stator and rotor including replacement of bearing bush, oil seal etc, re-assembling the same and lowering the pumping set including electrical & mechanical connection & testing commissioning complete all as specified and directed. Note :(i) Cost of pumping out the water from sump while lifting & lowering the pump is inclusive in quoted rate.
S&F AC 3 phase preventer 415 volts model 4SP-2 complete with connection & wiring including taking down old one complete all as directed. Make : Minilac or equivalent
S&F PVC insulated water proof 3 core cable suitable for submersible pump set 1100 volts grade with standard copper conductor cable of size 6 sqmm complete all as specified and directed including taking down old one.
S & F MS clamp (two part), made out of MS flat iron 65mm x 10 mm of suitable length and reqd. size of GI nuts, bolts and washers, suitable for holding 80 mm bore column pipe including one coat of zinc chrome primer and one coat of Bituminous paint complete all as directed including taking out old unserviceable.
M&L for Resilient seated gate valve both end flanged class PN 1.6 cm firming to IS with iron wheel head and brass spindle of size 150 mm bore gate valve including necessary nuts bolt, washer, rubber/fibre board gasket complete all as specified and directed including taking down old one.
M&L for Resilient seated gate valve both end flanged class PN 1.6 cm firming to IS with iron wheel head and brass spindle of size 100 mm bore gate valve including necessary nuts bolt, washer, rubber/fibre board gasket complete all as specified and directed including taking down old one.
M&L for Resilient seated gate valve both end flanged class PN 1.6 cm firming to IS with iron wheel head and brass spindle of size 80 mm bore gate valve including necessary nuts bolt, washer, rubber/fibre board gasket complete all as specified and directed including taking down old one.
M&L for Resilient seated non return valve suitable for 150 mm bore pipe both end flanged and fixed to the existing pipe line including necessary nut bolt, washers, rubber/fibre board gasket etc complete all as specified and directed including taking down old one.
M&L for Resilient seated non return valve suitable for 100 mm bore pipe both end flanged and fixed to the existing pipe line including necessary nut bolt, washers, rubber/fibre board gasket etc complete all as specified and directed including taking down old one.
M&L for water pressure gauge 4" dial 0-14 kgs rating including fixing arrangement with drilling tapping of existing pipe line complete all as specified and directed.
Taking up existing sewage pump set along with column pipe from the semi underground sewage sump of capacity 10 HP, cleaning thoroughly all serviceable spare and overhauling the pump with machine work and repairing by replacing the minor parts of the pump i.e. locknuts, impeller key, collaring etc.with nuts bolts & washer and lowering the same testing & connection complete. (Note: Major spare parts like shaft, Angular contact bearing, bush, Oil seal, holding clamp, Shaft sleeves if required shall be measured and paid separately as supply only under respective items in this Schedule).
Supply and fixing stainless steel shaft for swage pumping set of capacity 10 HP.
Supply and fixing Angular contact bearing for swage pumping set of capacity 10 HP.
Supply and fixing GM bush for upper bearing house for swage pumping set of capacity 10 HP.
Supply and fixing GM bush for line shaft for swage pumping set of capacity 10 HP.
Supply and fixing Oil seal for swage pumping set of capacity 10 HP.
Supply and fixing MS holding clamp 18" long 4" wide with nuts & bolts for swage pumping set of capacity 10 HP.
Supply and fixing Shaft sleeves for swage pumping set of capacity 10 HP.
Supply and fixing GM bush for lower bearing house for swage pumping set of capacity 10 HP.
Opening of first manhole cover from the sump and pumping out all water from sewage sump, blocking sewage line to sump providing jute bag at first manhole & cleaning the sump thoroughly with the help of wire brush after removing the sludge / silt & other foreign materials complete, removing the blockage from the first manhole complete of capacity 25000 gallons, including removing the sludge from pump house premises & depositing away from defence area complete all as specified and directed.
Cleaning of underground / semi under ground/ static tank/ sump of capacity 80000 - 200000 ltrs double chamber by taking out sludge from bottom of tanks, scrapping out scale from bottom & wall with the help of wire brush forming the roof washing out wall & bottom by applying bleaching powder solution, draining out complete materials from tank including writing date of cleaning all as directed.
Cleaning of underground / semi under ground sump of capacity 250000 - 500000 ltrs double chamber by taking out sludge from bottom of tanks, scrapping out scale from bottom & wall with the help of wire brush forming the roof washing out wall & bottom by applying bleaching powder solution, draining out complete materials from tank including writing date of cleaning all as directed.
Cleaning of underground / semi under ground sump of capacity 20000 - 50000 ltrs double chamber by taking out sludge from bottom of tanks, scrapping out scale from bottom & wall with the help of wire brush forming the roof washing out wall & bottom by applying bleaching powder solution, draining out complete materials from tank including writing date of cleaning all as directed.
Cleaning of underground / semi under ground sump/ GRP tank (above the ground) of capacity 50000 gallons double chamber by taking out sludge from bottom of tanks, scrapping out scale from bottom & wall with the help of wire brush forming the roof washing out wall & bottom by applying bleaching powder solution, draining out complete materials from tank including writing date of cleaning all as directed.
Cleaning of PVC tank of capacity 500-2000 ltr by taking out sludge from bottom of tanks, scrapping out scale from bottom & wall with the help of wire brush forming the roof washing out wall & bottom by applying bleaching powder solution, draining out complete materials from tank including writing date of cleaning all as directed.
Cleaning of PVC tank of capacity 10000 ltr by taking out sludge from bottom of tanks, scrapping out scale from bottom & wall with the help of wire brush forming the roof washing out wall & bottom by applying bleaching powder solution, draining out complete materials from tank including writing date of cleaning all as directed.
M&L PCC 1:4:8 type D2 type (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete etc complete all as specified and directed.
S&F PVC tubing cat part no 214531 for decrin dozing pump complete all as specified & directed including taking down old one.
M&L preparing old steel surfaces of any description width and girth and applying one coat of synthetic enamel paint all as specified and directed.
Repair & servicing of decrin dosing pump of capacity 2 ltr/ hours by opening the pump and checking all the spares parts minor defective parts if required and re-assembling and testing complete all as specified & directed. (NOTE:- (i) Cost of new minor spare parts included in the quoted rate.)
Development of existing bore well of any size by using compressor with necessary arrangement to remove the sand/waste materials inside the bore well with pressure of air upto 4.5 kg/sq cm not less than 48 hrs untill obtaining sand free water complete all as directed.
Taking out 63 mm OD UPVC pipe with all fittings refixing and jointing by cutting, welding in each joint and then FRP lining for each joint to make leak proof with new fittings ie. elbow, socket, with threaded, MT socket and GI socket as required and connecting to existing pipe and testing complete all as directed
Taking out 110 mm OD UPVC pipe with all fittings refixing and jointing by cutting, welding in each joint and then FRP lining for each joint to make leak proof with new fittings ie. elbow, socket, with threaded, MT socket and GI socket as required and connecting to existing pipe and testing complete all as directed
Taking out 160 mm OD UPVC pipe with all fittings refixing and jointing by cutting, welding in each joint and then FRP lining for each joint to make leak proof with new fittings ie. elbow, socket, with threaded, MT socket and GI socket as required and connecting to existing pipe and testing complete all as directed
Repair & overhauling the booster pump of capacity 5/7.5/10 HP make KIRLOSKAR by replacing the coupling for pump & motor, bush, gland, packing, nuts bolts all as specified & directed.
Repair & overhauling the booster pump of capacity 1/1.5/2/3 HP make KIRLOSKAR by replacing the coupling for pump & motor, bush, gland, packing, nuts bolts all as specified & directed.
S&F Fully automatic star delta (FASD) Starter in sheet steel enclosure type MN with single phase protection feature, motor rating AC- 3 duty, 415V, 50Hz, 3 phase,relay range 13-21 Amps including taking down old one complete all as specified and as directed. (Make : L&T / Legrand or equivalent ).
Chemical analysis Lab Test : (Turbidity, PH, Total hardness, Iron (Organic & Inorganic Iron), Chlorides, Sulphates, Fluorides, Calcium,Colifrom) of RO Plant Treated water from Dumayune Avanue & INS Netaji Subhash area from Govt Approved Laboratory including collection of water, Sterilized bottle for testing and submission of the test report.
Repairing to Valve Pit chamber with replacement valve pit MS sheet cover of size 600x600x5 mm th. with MS handle, freaming angle along with locking arrangement, PCC work in floor, brick work, plastering and applying two coats synthetic enamel paint to MS sheet complete all as specified and directed.
Repair of Oxidation / Softner/ Iron Removal chamber in IR plant including necessary welding and form works to match shape of dished/vertical portion of vessel (MS plate of thickness 8 mm, MS pipe of suitable dia & connected accesories inclded materials) complete all as directed and specified.
Supply only chlorine test kit with colour ample and OT solution in rexin finish wooden box complete all as specified and directed.
Supply only OT solution for chlorine test bottle(500 ml) complete all as specified and as directed
Supply only PH test kit with colour ample covered phenol red (range 6.8 to 8.4) with necessary fitments and 100 ml testing solution in rexin finish wooden box for testing of water complete all as specified and directed.
Supply only Phenol red solution for PH test bottle(500 ml) complete all as specified and as directed.
S&F GI sheet 6mm thick with suitable size and handle fabricated on it complete all as specified and as directed.
Supply and fixing glow sign board of size 1.0m X0.8mX0.18M depth made out of 0.80mm thick PGI sheet including necessary structural/fabrication work with MS round/rectangular hollow section with necessary bolts, nuts etc and provision of 3 Nos 8 watt LED light pre wired incl PVC cable connector and connecting up with twin core copper conductor ISI marked and providing high resolution vinyl printing at front over white acrylic sheet 5 mm as per design/lettering ( the subject shall be given by the EIC), including mounting arrengement, 30mmx30mmx1mm thick anodised aluminium angle beading all round, including nuts, bolts, fixing arrangements on walls to the installation all as per existing shape and size at site complete all as specified and as directed .
Supply only STEQUA 411 AE REFILL item description: Chlorine tablets contained in plastic cylindercal sealed dispossable sanitiser refill for disinfecion of drinking water with arrangement for controlled replease of disinfectant in water, suitable for operation throughrecommended dosing system. (a) Replacement indication: Visual & weight variation. (b) Water contract orifice desing : Sealed when dry, exposed upon immersion. (c) Operation type : Non Contace, Non inhalatory. (d) Cylinder Dia: 2.5 inches+/- 0.5 inches (Make- Declibac, potter & watts, Brio Zing).
S&F PVC machine history sheet / chart with details engraved of suitable size including taking down old one complete all as specified and as directed .
S&F water supply / electric supply / fire fighting net work diagram chart acrylic PVC sheet 1 mm thick complete all as specified and as directed .
Repair and maintenance of RO water filter of 10 Ltrs capacity and associated accessories by cleaning all filters, replacing RO membrane, sedimental carbon block, sedimental vatridge and micron overhauling of Booster pump, SMPS panel, low oressure switch and solenoid valve as and when required complete all as specified and directed .Note -Price for items to be replaced are deemed included in the item rate
Excavating in trenches n. exc. 1.5 m. wide and exc. 1.5 m. in depth; for L poles . n. exc. 10 sqm on plan and not exc. 1.5 m. in depth and getting out in soft/loose soil complete all as specified and as directed.
Supply and laying well burnt bricks sub class 'B' laid breadth wise along length of cable in trenches after sand cushioning laid for underground cable protection complete all as specified and as directed
Laying only old unsv burnt bricks sub class 'B' laid breadth wise along length of cable in trenches after sand cushioning laid for underground cable protection complete all as specified and as directed
Cutting and clearing the tree branches/bushes around the LT street light poles upto 3 mtr from centre of pole and clear the site and throw away the branches/bushes to a distance all as specified and as directed .
M&L for Steel tubler swaged poles complete with cast iron base plate finial taper plug, bolts, nuts and screws,with two holes for drawing conductor between pole box to street light fitting all as specified type 410 SP-31 of height 9M including painting with two coats of aluminium paint over one coat of primer including Zebra marking with synthetic enamel paint and applying black bituminious paint to the buried surfaces in ground including taking down old one complete. NOTE: Earth work,PCC will be measured and paid separtely under relevent item of this Schedule.(Make-Calcutta poles/ Bansal/ Utkarsh)
Supply and fix MS Bracket made of 50mm dia MS pipe medium grade 1.5mtr long suitable for street light on steel / RCC pole as per site requirement including suitable nut,bolt and clamps complete accesseries all as specified and directed and taking out old one.
M&L preparation of old painted surface above the planting depth and PCC coping of steel tubular LT pole of upto 9.00 metre length including MS clamps ,cable protection pipe bracket fitted with street light fittings etc by scraping with steel wire brush and applying two coats, of aluminium paint to external surface of poles MS cross arms MS clamp, cable protection pipe etc to give even shade including Zebra colour of painting from 2.1 mtr height from the top of caping/ bottom of pole as per site condition and numbering of poles complete all as specified and as directed by Engr-in –charge. Note: Zebra colour will be applied by synthetic enamel paint of black/yellow colour as approved in alternate layer of 30 cm height of each layer.
Supply and Replacement of three pole power contactor, 415 Volts, ML-2, Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1, l Range from 32A AC-3, l Robust and suitable for hostile applications for street light control including electric connection complete including taking down old one. (Make L & T /GE/SCHNEIDER/LEGRAND).
Supply & fix street light timer Timer FM1 / Quartz Daily 240V AC Base/DIN Mounting analogue type suitable for street light control complete all as specified & directed including taking down old one.(Make L & T /GE/SCHNEIDER/LEGRAND).
S&F MCCB 16 Amps, 4 Pole,16 KA breaking capacity, 415V thermal magnetic release. including taking out old one complete all as specified and directed.(Make L & T /GE/SCHNEIDER/LEGRAND).
S&F MCCB 25 Amps, 4 Pole,16 KA breaking capacity, 415V thermal magnetic release.including taking out old one complete all as specified and directed. (Make L & T /GE/SCHNEIDER/LEGRAND).
S&F MCCB 40 Amps, 4 Pole,16 KA breaking capacity, 415V thermal magnetic release. including taking out old one complete all as specified and directed. (Make L & T /GE/SCHNEIDER/LEGRAND).
S&F MCCB 63 Amps, 4 Pole,16 KA breaking capacity, 415V thermal magnetic release. including taking out old one complete all as specified and directed.(Make L & T /GE/SCHNEIDER/LEGRAND).
Supply and fix MCB SP 240V, 6-32 Amps capacity including taking down old one complete all as specified and directed. (Make L & T /GE/SCHNEIDER / LEGRAND).
Supply and fix MCB DP 240V, 6-32 Amps capacity including taking down old one complete all as specified and directed. (Make L & T /GE/SCHNEIDER / LEGRAND).
Supply and fix MCB TPN 240V, 32 Amps capacity including taking down old one complete all as specified and directed. (Make L & T /GE/SCHNEIDER / LEGRAND).
Supply and fix MCB TPN 240V, 63 Amps capacity including taking down old one complete all as specified and directed. (Make L & T /GE/SCHNEIDER / LEGRAND).
Material and labour for PVC cable end terminal boxes outdoor type, 30x20cm, PVC door, sintex box provision for cable incoming and outdoing from bottom, comprising of one MCB SP 6-32 Amps, cable glands suitable and one porcelein connector four way completed fixed on wall/pole with necessary clamps, screw etc all as specified and directed including taking out old one. Make Sintex or equivalent
Taking out old unserviceable LT cables of cross sectional area upto 25 sqmm including bricks or pre-cast concrete cable cover etc of any description from trenches / walls / poles by disconnecting the cable from pole /feeder /panel board etc. and keep serviceable bricks or pre-cast concrete cover, cable, pipe etc. in safe custody for re-use and unserviceable materials removing from site all as specified and as directed. Note : (i) Excavation and earth work shall be measured and paid separately.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 10 Sqmm 2 core complete all as specified and as directed.
Supply and laying in trenches or fixing or passing through pipes or fixed to wall/pole 1100 volts grade PVC/ XLPE insulated armoured heavy duty electric cables (conforming to IS :1554(Part- I) / IS 7098 (Part- I)with aluminium conductor of cross sectional area 16 Sqmm 4 core complete all as specified and as directed.
M&L sub main wiring two single core, PVC insulated, unsheathed, multistranded copper conductor, 2x 2.5 sqmm and 1x 2.5 Sqmm (FRLS) earth wire drawn through and including 20mm dia PVC conduit (medium duty) with all accessories fixed to wall/ poles with saddles and screws including taking down old wiring complete all as specified and directed by Engr-in-Charge. Note: One run of 2.5 sqmm and two run of 2.5 sqmm, copper wire with proper colour coding , viz, phase(Red), neutral (Black) and earthing (Green) should be measured as one unit only).
Supply & fixing 20 mm dia medium grade PVC rigid conduit with all fittings and accessories of PVC RIGID CONDUIT (like Tee, bend etc.) complete all as specified and directed.
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron or steel earth lead wire 4.0 mm dia by means of nuts, bolts, check nuts and washers of galvanised iron or steel, earth wire protected by galvanised iron pipe 35 mm dia (light grade), 7.5 mtr long and connected to main switch board or main control panel as directed and as specified including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 5 cm thick of size as shown reinforced with 8 mm dia TMT / deformed bars 100 mm c/c both ways including one handle made of 12 mm dia MS bars of length 500 mm, funnel, wiremesh 20 mm bore galvanised iron pipe medium grade for watering, charcoal and salt in alternate layers including necessary earth work complete all as shown in elect plate No. 3 of SSR Part I, all as directed including taking down old one .
M&L for LED street light luminaire 200Watt, IP protection 65, class-I, driver intergral (inbuilt 4kV SPD, driver efficiency >90%, system efficacy >90 lm/W, operating voltage range 120V- 270V luminaire operates upto 300V, 50 Hz, PF ≥0.95, CCT 5700K, ANSI, CRI >70, beam angle 60° connection complete including taking down old unserviceable fitting all as specified and directed. (Make : Crompton Greaves /Philips/Havells/ Bajaj.)
M&L for LED street light luminaire 150Watt, IP protection 65, class-I, driver intergral (inbuilt 4kV SPD, driver efficiency >90%, system efficacy >90 lm/W, operating voltage range 120V- 270V luminaire operates upto 300V, 50 Hz, PF ≥0.95, CCT 5700K, ANSI, CRI >70, beam angle 60° connection complete including taking down old unserviceable fitting all as specified and directed.(Make : Crompton Greaves /Philips/Havells/ Bajaj.).
M&L for LED street light luminaire 120Watt, IP protection 65, class-I, driver intergral (inbuilt 4kV SPD, driver efficiency >90%, system efficacy >90 lm/W, operating voltage range 120V- 270V luminaire operates upto 300V, 50 Hz, PF ≥0.95, CCT 5700K, ANSI, CRI >70, beam angle 60° connection complete including taking down old unserviceable fitting all as specified and directed.(Make : Crompton Greaves /Philips/Havells/ Bajaj.)
M&L for LED street light luminaire 90Watt, IP protection 65, class-I, driver intergral (inbuilt 4kV SPD, driver efficiency >90%, system efficacy >90 lm/W, operating voltage range 120V- 270V luminaire operates upto 300V, 50 Hz, PF ≥0.95, CCT 5700K, ANSI, CRI >70, beam angle 60° connection complete including taking down old unserviceable fitting all as specified and directed.(Make : Crompton Greaves /Philips/Havells/ Bajaj.)
M&L for LED street light luminaire 60Watt, IP protection 65, class-I, driver intergral (inbuilt 4kV SPD, driver efficiency >90%, system efficacy >90 lm/W, operating voltage range 120V- 270V luminaire operates upto 300V, 50 Hz, PF ≥0.95, CCT 5700K, ANSI, CRI >70, beam angle 60° connection complete including taking down old unserviceable fitting all as specified and directed.(Make : Crompton Greaves /Philips/Havells/ Bajaj.)
M&L for LED street light luminaire 40Watt, IP protection 65, class-I, driver intergral (inbuilt 4kV SPD, driver efficiency >90%, system efficacy >90 lm/W, operating voltage range 120V- 270V luminaire operates upto 300V, 50 Hz, PF ≥0.95, CCT 5700K, ANSI, CRI >70, beam angle 60° connection complete including taking down old unserviceable fitting all as specified and directed.(Make : Crompton Greaves /Philips/Havells/ Bajaj.)
M&L for LED street light luminaire 20Watt, IP protection 65, class-I, driver intergral (inbuilt 4kV SPD, driver efficiency >90%, system efficacy >90 lm/W, operating voltage range 120V- 270V luminaire operates upto 300V, 50 Hz, PF ≥0.95, CCT 5700K, ANSI, CRI >70, beam angle 60° connection complete including taking down old unserviceable fitting all as specified and directed.(Make : Crompton Greaves /Philips/Havells/ Bajaj.)
M&L for LED flood light luminaire 80Watt, IP protection 65, class-I, driver intergral (inbuilt 4kV SPD, driver efficiency >90%, system efficacy >90 lm/W, operating voltage range 120V- 270V luminaire operates upto 300V, 50 Hz, PF ≥0.95, CCT 5700K, ANSI, CRI >70, beam angle 60° connection complete including taking down old unserviceable fitting all as specified and directed.(Make : Crompton Greaves /Philips/Havells/ Bajaj.)
M&L for LED flood light luminaire 120Watt, IP protection 65, class-I, driver intergral (inbuilt 4kV SPD, driver efficiency >90%, system efficacy >90 lm/W, operating voltage range 120V- 270V luminaire operates upto 300V, 50 Hz, PF ≥0.95, CCT 5700K, ANSI, CRI >70, beam angle 60° connection complete including taking down old unserviceable fitting all as specified and directed.(Make : Crompton Greaves /Philips/Havells/ Bajaj.)
M&L for Decorative post top lantern for 360 degree , 40Watt, indirect light suitable for pipe 50mm dia including connection from connector to switch including taking down old one complete all as specified and as directed. (Make : Crompton Greaves /Philips/Havells/ Bajaj.)
M&L for outdoor type bollard LED luminaries, 10 watt with IP 65 protection,including suitable size of wire from joint box to connector with all necessary acceories such as wire clamps nut bolts and necessary PCC work including including taking down old unserviceable fitting complete all specified and directed.(Make : Crompton Greaves /Philips/Havells/ Bajaj.)
Supply and fixing LED aviation light 6 watt IP-65 luminaires comprising of aluminium housing with polycarbonate enclosure, incl taking down old one complete all as specified and as directed.(Make : Crompton Greaves /Philips/Havells/ Bajaj.)
Supply and fixing LED Spot light 7 watt (warm white) 240 volts 50Hz with all connecting fittings, incl taking down old one complete all as specified and as directed.
Supply and fixing LED Spot light 15 watt (warm white) 240 volts 50Hz with all connecting fittings, incl taking down old one complete all as specified and as directed.
Supply and fixing flexible LED Strip dot light 06 w/mtr power consumption with protection of IP- 65 and with all fittings arrangments incl taking down old one complete all as specified and as directed.
Supply and fixing Electronic driver for LED flood light / street light as per existing capacity including fitting arrangments incl taking down old one complete all as specified and as directed.
M&L fine sand, filling in trench for cable cushioning and gently punned down by manually with hands complete all as specified and directed.
MS JYOTI INDUSTRIES
SINHA ENTERPRISE
DILIP CONSTRUCTION
M A ENTERPRISES
INDIA ELECTRICAL EQUIPMENTS
S B ENTERPRISE
SPECIAL CONCRETE AND CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .