| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC HOUSE NO 164 SHASTRI NAGAR NEAR JAL NIGAM BABINA CANTT DISTT JHANSI UP | BABINA CANTT | JHANSI | UTTAR PRADESH | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹14.7 L+₹2.1 L (16.4%)Rejected-Finance 1442 1 NANADANPURA BABINA CANTT TEHSIL DISTT JHANSI UP | BABINA | JHANSI | UP | L2 | Rejected-Finance Other than
lowest
bidder | |
| 3 | L3₹15.7 L+₹3.0 L (24.1%)Rejected-Finance 640 MAIN ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UP | 284401 | L3 | Rejected-Finance Other than
lowest
bidder | |
| 4 | L4₹15.9 L+₹3.2 L (25.7%)Rejected-Finance NEAR PUMP HOUSE ROAD NEAR RED ROSE SCHOOL BABINA CANTT JHANSI DISTT UP 284401 | JHANSI | UTTAR PRADESH | 284001 | L4 | Rejected-Finance Other than
lowest
bidder | |
| 5 | L5₹16.0 L+₹3.3 L (26.3%)Rejected-Finance C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L5 | Rejected-Finance Other than
lowest
bidder |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
13 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BABINA
GE BABINA CANTT 284401
REPAIR/MAINTENANCE SEWAGE PUMPING INSTALLATIONS AND MBBR BASED SEWAGE TREATEMENT PLANT AT MAP PHASE-II UNDER GE BABINA
2022_MES_562995_1
GE/BAB/TOKEN/55 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
270 days
GE BABINA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BABINA
₹30,000
Yes
14 Jan 2023
14 Nov 2022
15 Dec 2022
14 Nov 2022
13 Dec 2022
29 Nov 2022
Amount
Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr depth for pole / cable / foundation etc including getting out in hard / dense soil complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layer not exc. 25 cm in any type of soil after the pipe are laid & tested complete all as specified and directed.
Removing excavated soil to a distance n. exc. 50 m and depositing where directed at a level not exc 1.50 m above the starting point complete all as specified and directed.
M & L for laying of dry, clean fine sand as in cushion or filling in trenches around underground cable, in ducts, inside sub station complete all as specified and directed.
M&L for PCC cable cover class LV type 1 flat size 250 mm x 150 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified & directed.
M & L for cutting of road up to 0.6 mtr deep suitable for laying underground cables/MS tubes of any 40mm dia.and making good the disturbed area to match with the existing level with cement concrete and removing the surplus spoil to a distance up to 50 mtr complete all as specified and as directed by Engineer in charge
M&L for PVC Insulated, unsheathed multi stranded copper conductor cable, heavy duty, 1100 Volts grade single core 10 Sqmm in replacement for connection from LT panel board to motor starters and from starters to electric motors including necessry cable end termination with copper lugs of suitable size all as directed, confirmong to IS:694drawn through concealled heavy grade PVC conduites of not less than 32 mm nominal dia with necessary fittings such as bends, sockets etc. laid under the floor or fixed to the walls with suitable clamps or saddles including taking down of existing cable all as specified and directed
M&L for PVC Insulated, unsheathed multi stranded copper conductor cable, heavy duty, 1100 Volts grade single core 16 Sqmm in replacement for connection from LT panel board to motor starters and from starters to electric motors including necessry cable end termination with copper lugs of suitable size all as directed, confirmong to IS:694drawn through concealled heavy grade PVC conduites of not less than 32 mm nominal dia with necessary fittings such as bends, sockets etc. laid under the floor or fixed to the walls with suitable clamps or saddles including taking down of existing cable all as specified and directed
Supply and Fix in repair cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cable(heavy duty) 1100V grade with stranded aluminium conductor of Size 35 SqmmX3.5 core including taking out of existing cable all as specified and directed
As per item No 9 above but Cable of size 25 SqmmX3.5 core
S&F in replacement mild steel column pipe 150mm nominal dia, heavy duty with MS flange screw and welded both ends, flanges fabricated from 16mm thick MS plate with 4Nos MS ribs of 10mm thick for each flange complete all as specified and directed.
S&F in replacement mild steel column pipe 100MM nominal dia, heavy duty with MS flange screw and welded both ends, flanges fabricated from 16mm thick MS plate with 4Nos MS ribs of 10mm thick for each flange complete all as specified and directed.
S&F in repalcement butterfly valve of Size 50mm dia all as specified and directed
Taking out old un-serviceable GI pipes, laid in trenches or under floors or fixed to walls including all fittings and disconnecting from branch connections complete all as specified & directed, for sizes 100mm bore
All as per item no 14 but 25mm bore
All as per item no 14 but 20 mm bore
All as per item no 14 but 65 mm bore
S & F in replacement of galvanised steel water tubing medium grade 100 mm bore ISI marked with all fittings such as bends, elbow, socket etc laid under floors/trenches or on walls with fixing arrangments including leakage testing complete all as specified and directed.
All as per item no 18 but 25mm bore
All as per item no 18 but 20 mm bore
All as per item no 18 but 65 mm bore
M&L for earthing complete including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth strip 32x6 mm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 40 mm dia. light grade pipe and watering pipe shall be 20 mm ore medium grade PCC pipt with pre cast RCC cover, charcoal/salt funnel etc. complete all as directed. Note : The conctrete pit shall be PCC 1:3:6 type C1, 40 mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @10 cm C/C on both sides with suitable cast iron handle shall be provided in liew of cast iron cover shown in electrical plate No.5 of MES SSR Part-1 (ii) Item includes the cost of 7.5 m GI pipe for protectio of earth strip. (iii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends , elbows etc. shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length earth strip.
M&L for earthing complete including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire4 mm thick dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 20 mm dia. light grade pipe and watering pipe shall be 20 mm ore medium grade PCC pipt with pre cast RCC cover, charcoal/salt funnel etc. complete all as directed. Note : The conctrete pit shall be PCC 1:3:6 type C1, 40 mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @10 cm C/C on both sides with suitable cast iron handle shall be provided in liew of cast iron cover shown in electrical plate No.5 of MES SSR Part-1 (ii) Item includes the cost of 7.5 m GI pipe for protectio of earth strip. (iii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends , elbows etc. shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length earth strip.
M&L for MS Fabrication work,made out of structural steel sections as in frame work for cable & piping ducts/MS door panels etc at sewage installation ,MS angle /flats/plain sheet of appropriate gauge ,cut to size and made to the existing shape suitable for fixing MS chequred duct cover /door panel including nut and bolts and washers ,welding bracing work bending cold or hot drilling holes for bolts in any shapes or sizes as reqired including one coat of primer and two coat of synthetic enamel paint to the entire steel surface all as specified and directed.
S & F in replacement of cast iron sluice valve of 150 mm bore class PN-1.6 ISI marked (as per IS 14846 of 2000) heavy duty with flanged ends with high tensile SS spindle and gun metal check nut, iron hand wheel and fixing with providing suitable nuts, bolts, washers and rubber gasket for packing etc complete all as specified and directed.Note:- Any damage made to pipe lines, over head reservoir while replacing the sluice valve will be repaired by contractor on his own cost.
Discriptionl as per item No 25 here in before but 100 mm bore
Discriptionl as per item No 25 here in before but 80 mm bore
S&F in replacement cast iron foot valves of 150mm bore PN 1.6 as per IS 14846 to 2000 heavy duty with new rubber packing & nut, bolts complete all as specified and directed.
Discriptionl as per item No 28 here in before but 100 mm bore
Discriptionl as per item No 28 here in before but 80 mm bore
S&F cast iron non return valves 150mm bore swing type both end flanged PN 1.6 as per IS 5312 including necessary items such as nut, bolts, washers, rubber packing complete all as specified and directed.
Discriptionl as per item No 31 here in before but 100 mm bore
Suppling and fixing in replacement of Gun metal gate valve 20 mmbore with all GI fitting as per existing all as specified and directed
Suppling and fixing in replacement of Gun metal gate valve 25 mmbore with all GI fitting as per existing all as specified and directed
Supply installation ,commissioning and testing of LT panel indoor type,floor mounted,weather vermin proof factory made,CPRI approved,facricated out of 3mm thick mild steel sheet mounted ,on frame of mild steel angle iron 40mm X 40mm X 6mm ,45 CM above the ground level duly supported with mild steel angle iron 50mm X 50mm X 6 mm thick in PCC fondation (1:2:4) ,type B-1,Using 20mm graded crushed stone aggregate ,LT panel shall be totally enclosed with front double door and rear opening with IP-54 protection as per IS/8623 duly powder coated for 433 volts,3 phase ,4 wire having TPN Aluminium bus bars suitable for 500 Amp load duly drilled holes for connection ,RYB insulated with ndiffrent colour code and sleeved insulators complted prewired and cable connection with copper conductor wire upto copper bus bars including all incoming and outgoing cable connection with suitable size of copper lugs/gland complete all as specified and directed by Engr-in-Chrge and also comprissing of following:-INCOMING:(i) MCCB 4P,415V ,100 Amps 25KA breaking capacity with termal adjustable setting-01 Nos(ii) Phase indication light & control uses-01 Nos (iii) Aluminium bas bar 3 phase 4 strip suitable for 200 Amp current carring capacity complete with post insulators and heat shrinkable sleeves
OUTGOING (i) MCCB 4P,415V ,63 Amps 25KA breaking capacity with termal adjustable setting-02 Nos (ii) Phase indication light & control uses-01 Nos (iii) Volt meter 0-100Ampswith CTs plush type-02Nos (iv) Voltmeter 0-500 Volts analog type-01No (v) Cosmic star fully automatic star delta starter (ASD) suitable for 12.5HP to 15HP motor including overload relasy and single phase preventer- 01 No (vi) Phase sequence corrector-01 No
Dismantling existing water tank of any size and capcity from various sewage plant complete all as specified and directed
Supply and fixing in replacement of 1000 ltr capacity of rotational moulded polyethylene water storage tank 2 layered construction ISI marked of make as specified cylindrical vertical with closed top hoisted and fixing in position including 20mm GI pipe medieum grade wash out pipe 450 mm long with and 20mm dia GI pipe medium grade over flow pipe 600mm long with fitting including dismantling of existing water tanks of any type and capacity exceeding 1000 tr complete all as directed.
Supply and fix PVC bib tape of size 25 mm bore as per sample
Supply and fix PVC bib tape of size 20 mm bore as per sample
M&L for preperation of old decorated surface of steel and applyng one coat of synthetic enamel paint on exterior surface of steel structure ,panel boards ,machinary exposed valve pit cover PCC foundations ,sluice valve,pump set pipe lines,etc of sewage installations complete all as specified and directed by Engr-in charge.(Note:-Each installation equal to one job)
Dismantling and taking up unserviceable non clogging type centrifugal pump sets any size from foundations after disconnecting electric and water connections and transportation from site to contractor's work shop for carrying out repairs to pump sets / rewinding of motors as required incluidng re- assembling, re-fixing in position, including connecting and testing complete as specified and directed. Notes:- (i) Spare parts for pumps & motors including re-winding of motors shall be measured and paid separately under respective items of this schedule. (ii) Transportation charges of pump sets from MES installations to contractors work shop and back is deemed to be included in the quoted rates. (iii) Pump sets issued for repairs / re-winding shall be returned back / re-installed at site within three days from the date of receipt by the contractor. Any delay boyond 3 days shall be compensated through penal recovery @ Rs. 1000 per day per pump set. (iv) Rates for minor items such as nut bolts, washers, thimbles, lugs, etc are deemed to be included in the quoted rates.
M&L for opening up short circuited electric induction motor, 3 phase AC 440 Volts, 2 HP to 5 HP cutting and removing the short circuited stator winding coils complete and re-winding the same with super enamelled copper conductor wires of appropriate size as per the existing gauge including cleaning of slots, all necessary insulating materials, varnishing, drying and testing on load complete all as specified and directed
M&L for opening up short circuited electric induction motor, 3 phase AC 440 Volts, 7 HP to 12 HP cutting and removing the short circuited stator winding coils complete and re-winding the same with super enamelled copper conductor wires of appropriate size as per the existing gauge including cleaning of slots, all necessary insulating materials, varnishing, drying and testing on load complete all as specified and directed
M&L for opening up short circuited electric induction motor, 3 phase AC 440 Volts, 15 HP to 25 HP cutting and removing the short circuited stator winding coils complete and re-winding the same with super enamelled copper conductor wires of appropriate size as per the existing gauge including cleaning of slots, all necessary insulating materials, varnishing, drying and testing on load complete all as specified and directed
Supply & fix terminal connector for 2 HP to 5 HP motor with high trensile brass bolts & nuts, washers etc complete all as specified and directed.
Supply & fix terminal connector for 7 HP to 12 HP motor with high trensile brass bolts & nuts, washers etc complete all as specified and directed.
Supply & fix terminal connector for 15 HP to 25 HP motor with high trensile brass bolts & nuts, washers etc complete all as specified and directed.
Supply & fix 2 HP to 5 HP capacity PVC fan blade for motors as per the existing size complete all as specified and directed.
Supply & fix 7 HP to 12 HP capacity PVC fan blade for motors as per the existing size complete all as specified and directed.
Supply & fix 15 HP to 25 HP capacity PVC fan blade for motors as per the existing size complete all as specified and directed.
Repairs to rotors of squirrel cage induction motor 2 HP to 5 HP by metal filling, welding / cutting & grinding, polishing to required sizes for motors complete all as specified and directed.
Repairs to rotors of squirrel cage induction motor 7 HP to 12 HP by metal filling, welding / cutting & grinding, polishing to required sizes for motors complete all as specified and directed.
Repairs to rotors of squirrel cage induction motor 15 HP to 25 HP by metal filling, welding / cutting & grinding, polishing to required sizes for motors complete all as specified and directed.
M&L for motor end ball / roller bearing 2 HP to 5 HP with good quality grease suitable of pump sets complete all as specified and directed.
M&L for motor end ball / roller bearing 7 HP to 12 HP with good quality grease suitable of pump sets complete all as specified and directed.
M&L for motor end ball / roller bearing 15 HP to 25 HP with good quality grease suitable of pump sets complete all as specified and directed.
Supply only star rubber bush coupling for motor 2 HP to 5 HP complete all as specified and directed.
Supply only star rubber bush coupling for motor 7 HP to 12 HP complete all as specified and directed.
Supply only star rubber bush coupling for motor 15 HP to 25 HP complete all as specified and directed.
Supply only star coupling key any size as per sample complete all as specified and directed.
M&L for opening up centrifugal pump sets and replacement of unserviceable pump shaft 2 HP to 5 HP complete all as specified and directed.
M&L for opening up centrifugal pump sets and replacement of unserviceable pump shaft 7 HP to 12 HP complete all as specified and directed.
M&L for opening up centrifugal pump sets and replacement of unserviceable pump shaft 15 HP to 25 HP complete all as specified and directed.
M&L for opening up centrifugal pump sets and replacement of unserviceable pump impeller brass 2 HP to 5 HP complete all as specified and directed.
M&L for opening up centrifugal pump sets and replacement of unserviceable pump impeller brass 7 HP to 12 HP complete all as specified and directed.
M&L for opening up centrifugal pump sets and replacement of unserviceable pump impeller brass 15 HP to 25 HP complete all as specified and directed.
S&F in replacement of gun metal bush complete set of two as per sample for 2 HP to 5 HP complete all as specified and directed.
S&F in replacement of gun metal bush complete set of two as per sample for 7 HP to 12 HP complete all as specified and directed.
S&F in replacement of gun metal bush complete set of two as per sample for 15 HP to 25 HP complete all as specified and directed.
S&F in replacement of gun metal sleeves complete set of two Nos for 2 HP to 5 HP complete all as specified and directed.
S&F in replacement of gun metal sleeves complete set of two Nos for 7 HP to 12 HP complete all as specified and directed.
S&F in replacement of gun metal sleeves complete set of two Nos for 15 HP to 25 HP complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in foundations/foot path etc complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness below or above ground level including removal of debris complete all as specified and directed
S & F in replacement of MCCB four Pole 415 Volt AC breaking capacity 25 KA with fixed thermal and fixed magnetic setting of capacity 100 Amp conforming to IS:13947- II complete all as specified and directed.
S & F in replacement of MCCB four Pole 415 Volt AC breaking capacity 25 KA with fixed thermal and fixed magnetic setting of capacity 160 Amp conforming to IS:13947- II complete all as specified and directed.
Supply and fix in repair 50mm bore 3-layer PP-R polypropylene random copolymer pipe SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having terminal stability for hot and cold water supply including all PP-R plain & brass treaded polypropylene random fitting fixed complete to walls,ceiling or infloor including all fitting such as bend tee,nipple etc complete all as specified and directed
Supply and fix in repair PP-R gate valve of size 50mm complete all as specified and directed.
Cutting and removing unwanted grass and wild growth including bushes and shrubs from the roots below ground level at Sewage installations including removing boulders from a depth not more than 25 cms below normal ground level and depositing where directed and levelling / pruning the entire cleaned area to even finish complete all as specified and directed at site.
supply and fix cosmic star automatic star-delta starter for sewage motor capacity up to 12.5 HP complete all as specified and directed .
supply and fix cosmic star automatic star-delta starter for sewage motor capacity from 15 HP to 25 HP complete all as specified and directed .
Disconneting and taking down air compressor with 7.5HP electric motor carefully from foundation manually or mechanically and transporting to workshop for repair and back, installation, refixing, reconnecting to electric, refilling engine oil and piping work the repaired compressor complete all as specified and directed by Engr-in-Charge. Note:- The quoted rate shall be deemed to include the cost of transportation, fixing of spare parts, glandorry,new nut blot washers complete. Spare parts will be measured and paid for as supply only separately.
Supply and fixing non return valve suitable for 7.5 HP compressor
Supply and fixing cylinder liner suitable for 7.5 HP compressor
Supply and fix piston with 'O' ring suitable for 7.5 HP compressor
Supply and fix connecting rod suitable for 7.5 HP compressor
Supply and fix inlet valve suitable for 7.5 HP compressor
Supply and fix outlet valve suitable for 7.5 HP compressor
Supply and fix gasket set suitable for 7.5 HP compressor
Supply and fix piston pin suitable for 7.5 HP compressor
Supply and fix safety valve suitable for 7.5 HP compressor
Supply and fix pressure gauge suitable for 7.5 HP compressor
Supply and fixing in replacement of dosing pump as per existing in 300 KLD treatment plant all as specified and directed
M/L for top up Bio culture in 300 KLD sewage treatment plant complete all as specifide and directed by ENGI-IN-CHARGE
M&L for top up activated carbon media consist of single layer of activated carbon supported by graveles and pabbles at bottom,coconut shell carbon and coal based carbon used ,adsorption capacity up to 90% chlorine ,colour and odour removal 85 to 90% , top up up to 40 cm and maintain media density 500-700 kg/m3 all as specified and directed by Engr-in-charge.
M&L for top up dual media consist of silica sand (16-32 mm mesh) and anthracite( 0.6-1.2mm) provide more area & efficient filteration ,supported by gravels and pebbles at bottom, topup silica sand up to 10 Cm thickness and top up anthracite up to 10 cm thickness to maintain the filteration level up to 40 microns complete all as specified and directed by Eng-in-Charge.
Supply and filling moving bed Biological MBBR biofilm filter media having approx size 25X12mm,cylindrical with external fins,white/black coloured for the treatment of sewage plant of capacity 300KLD including removal of existing MBBR filter media of any size and shape by dewatering the tank and removing all sedimented particles of sludge,mud,sand ,vegetation etc complete all as specified and directed. Make:Biotech india Ltd/Aquatech international/Weldone water system
M&L for servicing of Sewage treatment plant based on moving bed bioreactor Aerobic attached growth technology manufactured by Fontus water pvt Ltd. including servicing ,checking and greacing/lubrication of 02 No Feed pump of Capacity up to 5 HP,Cleaning of one NO equalisation tank,greacing and testing of one Bar screen ,oil & grease trap,Cleaning ,checking of two moving bed bio reactor with media by visual checking of growth of Bio-Film and re-seeding of required quantity of MBBR media for propagate biofilm (bacteria colonies) and submit the report if effectiveness of the tratment plant. Servicing ,checking and greacing/lubrication of 02 Nos Filter feed pump and moter set of capacity 10HP to 15 HP,opening of 01 No dual media filter and 01 No activated carbon media filter and checking the condition of existing media ,cleaning and removing all sediment particles of sludge,mud ,sand,vegetation and refix at original position complete including testing and submit the test report of filtered water as per sewage charactristic for the treated water are followed under:- (i) BOD (PPM) Treated waste water < 30 (ii) COD (PPM) Treated waste water < 250 (iii) TSS (PPM) Treated waste water < 30 (iv) Oil & Grease Treated waste water <1000
Item No 97 (Contd..) Note A : 1. The plant shall be visited twice as directed during contract period by auth service technician/Engineer of Fontus water pvt ltd or equivalent STP manufacturing or authorised service patner company approved by GE and will check all parameter /defects and growth of biofilm on the MBBR media and submit report to Engineer in charge.All necessary repair /servicing will be done by auth service engineer .Cost visiting charges of engineer are deemed to be include in unit rate. 2. All spares/material reuired will be paid and measured separately against relevent items of schedule hereunder. Note B: The unit rate includes the following manadatory works (i) Checking of condition of MBBR media ,dual media and activated carbon media.changing of media shall be measured and paid separately. (ii) Carry out preventive maintenance as per the company recommandations and standard practice in every visit .Lubricating the bearing and motors & fans (iii) Checking the growth of biofilm observed on the MBBR media ,Biochemical Oxygen Demand (BOD) Removal efficiancy,range of F/M Ratio,Chemical Oxygen Demand (COD) Ratio and ensuring healthy condition of the plant. (iv) Taking set of reading and evaluating to ensure satisfactory performance of the plant (v) Checking of functioning of air blower in every visit and set the pressure required to propagete of the bacteria colonies. (vi) Checking the pump moter set of existing size and repair the leakage and greacing/lubrication of moving part. (Vii) Servicing/repairsworks will be carried out whitin 05 days after intimation to contractor on telephone followed in writing.Any delay beyound 05 day shall be penalised through panel recovery @ Rs 4000 per day till rectification/repair starts.
M&L Preparation of old surface by scraping and smoothing the surface with water emery paper and painting with approved colour of synthetic enemelled paint of two coat over a coat of primer red oxide and writing letter/numbers (SM/MES Nos and Date of Cleaning) of sewage treatment plant of capacity 300KLD and cleaning the surrounding area up to three meter outside area of the plant by cutting grasses and surface dressing for Moving Bed Bio Reactor 1 & 2etc complete all as specified and directed
All as per item No: 101 above but dual media filter
All as per item No: 101 above but Activated carbon filter
All as per item No: 101 above but Exposed water pipe lines
All as per item No: 101 above but Filter feed pump 1 & 2
All as per item no 101 abive but Distribution panel board
All as per item No 101 above but Air blower with compressor 1&2
Cleaning of sludge drying beds (04 nos) removing all sludge and de-scaling vegitation on the inside and outside of sludge bed and white washing (Two coat) including cleaning the surrounding area of the sludge drying beds to a distance of 3 meter circumstance including cutting of grass ,digging out roots ,filling holes and levelling around and removing waste material to a distance not exceeding 50 Mtrs complete alll as specified and directed . Note: item Ser No:05 to18 (i) Adequate manpower including necessary T&P and safty precaution to the individual working /carry out job at site is the responsibility of the contractor and the cost include in the quotated rate. (ii) All inlet/outlet pipes/ channels shall be properly sealed at the opening inside the clarifer while carring out cleaning. (iii) The work mentioned in item Ser No 05 to 18 will be carried out within 07 days after intimation to contractor on telephonic followed in writing .Any delay beyound 07 days shall be penalished through panel recovery @ 1200 per day till rectification/repair.
All as per item No 108 but Equilization tank and air grid
All as per item No 108 but Bar screen and pit
All as per item No 108 but oil and grease trap
All as per item No 108 but Tube settler tank
All as per item No 108 but Clean water tank
All as per item No 108 but chlorine contact tank
M&L for cleaning of sludge chamber at W Wing sewage plant having dia up to 4.5mtr and depth up to 7 mtr manually including de-watering and removing all sedimented particles of sludge,mud,sand ,vegetation etc,from the clarifer sump and deposting where directed at a distance not exceeding 50mtr including brushing / scrubbing to remove all scales or any fungus growth from the entire surfaces and cleaning thoroughly with fresh water and applying a coat of lime wash to the entire interior surfaces all as specified. Note:(1) Adequate manpower inxluding necessary T&P, safety precaution to the individual working/carry out job at site is the responsibility of the contractor and the cost include in the quoted rate. (2)All inlet/outlet pipes/ channels shall be properly sealed at the opening inside the clarifer while carring out cleaning. (iii) Cleaning works will be carried out whitin 07 days after intimation to contractor on telephone followed in writing.Any delay beyound 07 day shall be penalised through panel recovery @ 1500 per day till cleaning starts.
All as per item No: 115 but ISF line sewage plant
All as per item No: 115 but Zone 12 sewage plant
All as per item No: 115 but Zone 4 sewage plant
All as per item No: 115 but Zone 8 sewage plant
S & F MS pump motor coupling of 2 HP to 15 HP as per the existing size and shape for pump and motor sets
M/S SHIVA TRADERS
M/s Ravi Traders
M/S Ritu Tandon
SHRI HARI CONSTRUCTION
ROHIT ENTERPRISES
M/S Kharya Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .