Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹44.5 LAccepted-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L-1 | Accepted-Finance LOWEST TENDERER | |
| 2 | L-2₹47.4 L+₹2.9 L (6.58%)Rejected-Finance BHAIRAVNATH NAGAR AT KUSGAON POST LONAVLA 410 401 DISTT PUNE | PUNE | MAHARASHTRA | 410401 | L-2 | Rejected-Finance GREATER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
17 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Komal Parihar
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
ADDN ALTN IMPROVEMENT TO BLDG NO P 30 P 49 P 47 P 23 P 28 AT AIR FORCE AND ADDN ALTN IMPROVEMENT TO ROOF TOP OF F BLOCK P 217 AND SPL REPAIR TO RESTORATION OF ROOF IN CERTAIN CMA AT INS SHIVAJI LONAVLA
2020_MES_399726_1
GE/LONAVLA/8958/E8
Open Tender
Civil Works
Item Rate
270 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
4 documents required · 4 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹88,000
Yes
21 Dec 2020
1 Dec 2020
19 Dec 2020
1 Dec 2020
17 Dec 2020
5 Dec 2020
2 Dec 2020 - 4 Dec 2020
60 days
Amount
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed..
Taking down cement or cement lime plaster of any description on brick or stone wall and ceiling surface including raking out joints, hacking for key, scrubbing down with water etc and disposing off the rubbish outside MD land complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles etc complete all as specified and directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) etc complete all as specified and directed.
M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specifed and directed.
M & L for ceramic tiles 8 to 10 mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with surface
Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6
M & L for ceramic tiles 8 to 10 mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in Dado/Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with surface.
M&L rendering in CM (1:4) 15mm thick cement plaster as in backing coat of brick/concrete surface with necessary adhesives finished rough to receive wall claddings/ cladding tiles and any finishes
M&L for External Wall tiles area of each tiles not exc 0.18 Sqm and thickness as per manufacturer approved fixed with blended powder polymer modified cement based stone tile adhesives of thickness of approx 3-6 mm thick combed with notched trowel and placed and tapped properly to ensure complete coverage of backside of tiles over adhesives including cleaning/ preparation of newely plastered surfaces to be tiled and making it free from wax, grease, polish,paints etc all as per manufacturers instructions Note :strictly apply the adhesive paste which can be tiled withing 10-15 minutes (Makes: Somany External wall tiles/Johnson tiles Kajaria) off Stone tile adhesives/Dr. Fixit Fevimate TL tile fixing adhesive Note : Item is required to be carried out at height upto 12 m above GL. Rate deemed to include for all necessary scaffolding and protective measures required to work at above height and also for fixing tiles in narrow widths
Complete removal of existing treatment of external surface of wall including removing fungus /algae dirt, oil, grease and loose particles by wire brush,cleaning, washing and removing dust, . Cracks less than 2 mm, should be cleaned free of dust with a vaccum cleaner and apply Dr. Fixit Primeseal (Efflorescence resistant penetrating primer.) let it dry. Then pour Dr. Fixit Raincoat into these cracks and wait for it to dry Apply the first coat of Dr. Fixit Raincoat without any dilution at the rate of 2 sqm per litre and allow it to dry before taking up the second and third coats, the rate of application being the same, Drying time between coats will be 6 to 8 hrs, A total thickness of 1 to 1.2 mm must be achieved when Dr. Fixit Raincoat is dry and including necessary scaffoldings etc , complete all as specified and directed Note:- Application of primer and paint shall be done by the authorised applicator of the manufacturer of the paint and a certificate to this effect shall be produced by the contractor.
M&L for PCC 1:3:6 type C-2 using (40mm graded stone aggregate) 75 mm thick for floor/plinth protection finished even and smooth without using extra cement complete all as specified and directed.
M&L for 18-20mm thick granite(of any type) work table rubbed and polished as in riser of steps, skirting, window cills( on horizontal or vertical surface),dado and pillar laid over cement mortar backing coat jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and including over 10 mm thick Rendering in CM1:4 complete all as specified and as directed.
M&L for powder coated aluminium three track and three shutter (of equal width) sliding type window without sash bars including necessary jointing clips, rubber packing, neoprene rubber gasket, aluminium snap beading, screws, aluminium fittings, handles, locking arrangement (star lock), bearings two No's for each shutter with 4.00mm thick sheet glass for glazing shutters & stainless steel wire cloth of 0.36mm nominal dia of wire & average width of aperture 1.40mm for wire gauge shutters including following powder coated sections as given in 'JINDAL' catalogue complete all as specified and as directed :- (i) Frame (Bottom)-20620. (ii) Frame (Top & Side)-20621. (iii) Shutter vertical (Handle lock)-20846. (iv) Shutter vertical (Int lock)-20845. (v) Shutter (Top)-20844. (vi) Shutter (Bottom)-20847. Note :- (i) The window opening shall be provided with three shutters of equal width. (ii) Two shutters shall be glazed shutters & one shutter shall be with stainless steel wire cloth all as specified hereinbefore. (iii) The shutters shall be placed in such a manner that at a time the entire width of window can be utilized as fully glazed window and at time the same can be utilized as partly glazed and partly gauzed window. (iv) The thickness of powder coating shall not be less than 0.5 micron & the tint shall be as decided by GE. (v) Unit rate quoted shall be deemed to include for sealing the gap of frame with Jamb and Cill (alround) using silicon gel at the rate of 0.05 lit/m for both faces of window.
Disconnecting existing tanks disconnecting existing tank, setting aside (or lowering if required) for repairs, cheaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repainring, etc. measured separately) , not exc 500 litrs tanks complete all as specified.
Disconnecting existing tanks disconnecting existing tank, setting aside (or lowering if required) for repairs, cheaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repainring, etc. measured separately) , exc 500& not exc 1000 litrs tanks complete all as specified.
S&F in repair for Tubes, ‘medium grade’ galvanised, 25 mm bore with all fitting and fixed complete to walls and ceilings or laid in floors etc complete all as specified and as directed.
Removing Completely removing existing water proofing treatment of any descriptions and any type including top layer of plaster / china mosaic wherever occurs over roof and chhajja surfaces and scrubbing the surface with wire brush and cleaning wash down with water to receive new cement plaster / PCC layer and removing the waste material / debris etc , complete all as specified and directed .
M/L for rendering 15 mm thick in cm 1:4 using readi plaster on concrete roof surfaces mixed with water and all as per manufacturer instructions etc, finishing the surface even and smooth without using extra cement etc , complete all as specified and directed Make:- Ultra Tech / Silico / Renaplast/Kaneria
M&L for water proofing treatment to RCC roof slab all as specified below and as directed:- (a) Apply one coat of bituminous primer @ 0.25 Kg/Sqm. (b) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/Sqm of the surface area. (c) Laying APP polymer modified membrane 4mm thick with non woven polyster reniforcement weighing not less than 4.00 Kg/Sqm applied by torch application method. (d) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/Sqm of the surface area. (e) Apply a coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm.
Removing building materials concrete, stone, brick etc., other than spoil to a distance of 10 km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination Note :- One metric tonne shall mean one load .
Taking up or down steel tubing 20 mm and connection, including cleaning for refixing or removal to store complete all as specified.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store (Bore of pipe in mm 25)
S&F CPVC pipes, SDR 11, 20 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all fittings such as Tee, bends, elbows ,unions ,sockets and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed.
S&F CPVC pipes, SDR 11, 25 mm outer dia of pressure rating 6kgf/sqcm conforming to IS-15778 with all fittings such as Tee, bends, elbows ,unions ,sockets and end pieces etc to receive fittings and fixed with solvents fixed to walls / ceiling with all clamps in Shafts/ducts with all necessary scaffolding to fix the pipes and testing the joints under prescribed pressure etc complete all as specified and as directed.
S&F Steel Water Tubing, ‘medium grade’ galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors Bore of tube in 20 mm
S&F Steel Water Tubing, ‘medium grade’ galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors Bore of tube in 25 mm
Demolition of PCC/Padding concrete of any type
M&L for PCC 1:2:4 type B0 (12.5mm graded agg) as in roof kerbs coving over chajjas and similar locations rounded or chamfered on edges.
Supply integral water proofing compound.
Dismantling / taking down PVC/ Cast iron soil /waste pipes 100 mm / 75mm bore including all fitting like bends and fittings etc
S&F 75mm bore PVC (SWR) pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails including all fittings such as couplers, bends, elbows clamps, brackets etc etc complete all as specifed and directed.
S&F PVC 100mm bore PVC pipe single socketed(ISI Marked) any length with rubber ring joints , complete fittings etc fixed to wall fixed with MS clamps8mm dia with two nuts wall nails including all fittings such as couplers, bends, elbows clamps, brackets etc etc complete all as specifed and directed.
Taking down chowkats or frames N.exc 1.5 Sqm with shutter (without taking of shutter from the frame.
S&F factory made PVC double door frame of size 50 mm x 95 mm made out of 5 mm single side prelaminted PVC sheet reinforced with MS Square tube all as specified and as directed .
S&F for 35 mm Factory made Moulded door shutter consisting of solid core single leaf flush door of 30 mm thickness,lipped with 15 mm (5mm x 3) thick x30 mm width on the other stiles & bottom rails & 10mm (5mm x 2) thick x 30 mm width on other stiles & bottom rails , The inner panel laminated with 2 mm thick termite proof, water proof and fire resistant molded PVC sheet with 2,4,6 raised panel designs in different plain and / or prelam colours after routing the Moulded design on one side & 2 mm plain and / or prelam PVC sheet on other side using rubber adhesive on flush door & solvent cement adhesive on the PVC Lipping and manufacturer's specification & drawing etc, complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
Factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
Taking down Chowkats or frames exc 1.5 sq. m but n exc 4 sq. m each but with shutters (without taking off shutters from the frame complete all as specified.
S&F 12 mm thick toughened glass doors of any size and design with suitable stainless steel patch fittings, locking arrangement , floor springs and 02 nos 300 mm long matt finish handles includng necessary acid wash/itching complete all as specified and directed.
S&F Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed in 2nd class hard wood
S&F Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats of 2nd class hardwood 30 mm thick
M & L for Preparation of old painted steel surfaces of any description having width/girth exceeding 10cm and apply one coat of synthetic enamel paint complete all as specified and as directed.
S&F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F 100 mm thick Butt hinges, medium weight, cold rolled mild steel, and fixed
S&F Aluminium bow handles, cast type, anodised 125 mm long
S&F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor 140MM Dia
Supply and fix aluminium alloy anodised Aldrop sliding door bolt with hasp and staple(bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolt of extruded section of size 300 mm fixed at any position all as specified and directed.
M&L for rendering 10mm thick in cement mortar 1:6 on brick work or concrete surfaces and finished even and smooth without using extra cement on walls
M&L for rendering 15mm thick in cement mortar 1:4 on brick work or concrete surfaces and finished even and smooth without using extra cement on walls
M&L for rendering in patches, n.exc 3 sqm each patch, 15 mm thick in cement mortar 1:4 on walls and finished even and smooth without using extra cement including taking down cement plaster on brick/concrete surfaces and raking of joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall applying two coats of Appex over a coat of alkali resistant primer
M&L for preparing newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer over and including 3.00 mm thick wall care putty complete all as specified and as directed. Note :- Application of primer and paint shall be done by the authorised applicator of the manufacturer of the paint and a certificate to this effect shall be produced by the contractor.
Preparing old steel Surfaces of any des-cription, over 10cm in width or grith, not otherwise described and applying two coats of Synthetic enamel paint over a coat of red oxide primer completed all as specified and directed.
M&L for complete removal of existing treatment of old painted wall surfaces and applying two coats of exterior grade weather resistant, antifungal acrylic latex paint on walls over a coat of primer complete all as specified and as directed. Note :- Paint shall be done by the authorised applicator of the manufacturer of the paint and a certificate to this effect shall be produced by the contractor.
M&L for making the grooves 25mm wide and 50mm deep to 'V' section in existing walls/columns over RCC roofs, cleaning out and tacked the polymeric membrane in to the grooves, inserting chajja of PPGI sheet and sealed solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc complete all as specified and directed.
M&L for disconnecting anf refixing of solar water geyser system
S&F in repairs 1000 ltrs Rotational mould polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-I complete all as specified and directed.
Dismantling mangalore pattern roofing tiles single layer including ridge tiles laid, bedded in cm complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed.
Dismantling battens for tiles any size exceeding 15cm in spacing complete all as specified and as directed.
Dismantling timber Scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed.
Dismantling of CGI/PGI sheet roofing any gauge and any thickness including ridge, valley gutter etc complete all as specified and as directed.
Dismantling Wall and ceiling boards of any type or insulation boards/slabs/blankets, any thickness, including cover fillets
Dismantling of MS works of any description such as ,ladders, grating etc, including necessary straightening of bends complete all as specified and directed.
S&F CGI sheeting 0.63 mm thick with two corrugation side lap fixed with L or J type bolts in roof walls etc with grade of zinc coating 275 gm/sqm complete all as specified and as directed.
S&F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with L or J type bolt, grade of zinc coating 275 gm/sqm complete all as specified and as directed.
S/F Tubular sections of size 40 x 25 mm thick as in rafters fixed with self tapping screw of size not less than 75mm and 25 x 25 mm thick for battens fixed on rafter over CGI sheet roof with necessary fittings and welding for supporting mangalore pattern roof tiles complete.
M&L for mangalore pattern roof tiles inter locking at side and joints laid dry complete all as specified and as directed.
All as per item No-70 here-in-before but except tile complete all as specified and directed.
M&L for Ridge or hip tiles to suit Mangalore pattern roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and as directed.
All as per item No-72 here-in-before but except Ridge or hip tile complete all as specified and directed.
M&L for Filleting in any position and to any shape in cement mortar 1:6 sectional area exc 25 but n. exc 50 Sqcm complete all as specified and as directed.
M&L for pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/manglore tile roof drops fixed with self tapping screws complete all as specified and as directed.
S&F Roof trusses (framed), sunshade frames, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410-W(Gde-E-250) all as specified and directed by Eng-in-Charge.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and as directed.
M&L for powder coated aluminium snap grid frame work for false ceiling, with aluminium angle 25mmx25mmx1.5mm fixed to perimeter of wall, Main 'T' runner 38mmx25mmx1.5mm and secondary/cross 'T' runner 25mmx25mmx1.5mm to be interlocked in such a way that the size of grid shall be 605mmx 605mm including 6mm dia GI hangers (upto 1200mm length) adjusting level fixed to roof by means of ceiling cleats made out of GI flat 40x3mm, 60mm long and expansion hold fastners 12.5mm dia, 40mm long complete all as specified and as directed. Note:- The thickness of the powder coating shall not be less than 0.5 micron & the tint shall be as decided by GE.
S&F for Plastic Ceiling tiles decorative surface of 595x595x7mm hot transfer printing and good dimensional stability when the temperature is below 45 degree and suitably fixed in false ceiling aluminium snap grid frame with staples or screws complete all as specified and as directed
M&L for preparation of new surfaces of steel, of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Disconnecting existing tanks disconnecting existing tank, setting aside (or lowering if required) for repairs, cheaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repainring, etc. measured separately) , Exc 1000 & n exc 2000 litrs tanks complete all as specified.
M/L for rendering 12 mm thick in CM 1:6 on brick walls finishing with sagol even and smooth (with out using extra cement)etc complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces in two coats (10 + 5 mm), both coat mixed with integral water proofing compound ISI Marked @ 2% by the weight of cement and finishing the surface even and fair complete all as specified and directed Note - WPC shall be measured and paid separately
M&L for preparation of old painted surfaces including brooming down or steel wire brushing scraping down smoke soot, moulds, moss: efforescent salts and trading oil, greasy spots and applying one coat of oil bound distemper and including wherever necessary filling of nail holes/ inequalities with Putty for smooth finish.etc complete all as specified and directed.
M&L for preparation of newly plastered roof surfaces thoroughly by cleaning, washing and removing dust, dirt, oil, grease and loose particles. Cracks less than 2 mm shall be sealed with "Pidilite URP" manufactured by Dr Fixit or with "Plaster seal" manufactured by STP and cracks more than 2 mm and less than 5 mm shall be sealed with " crack X wooder" manufactured by Dr. Fixit or " Plaster seal" manufactured by STP and applying primer and two coats of water proof decorative elastomeric coating of approved shade/colour complete all as specified and as directed. Note :- (i) Primer shall be " Prime seal "manufactured by Dr. Fixit" or "Plaster seal" manufactured by STP. (ii) Water proof decorative elastomeric coat shall be Rain coat DFT 100 manufactured by Dr Fixit or shalicry 215 manufactured by STP. (iii) The rate of application of primer and waterproofing coat shall be as per manufacturers instructions. (iv) A time gap of eight hours shall be maintained between the application primer and each water proof coat after application of sealant. (v) Unit rate quoted shall be deemed to include for necessary scaffolding for execution of the same. (vi) Application of primer and paint shall be done by the authorised applicator of the manufacturer of the paint and a certificate to this effect shall be produced by the contractor.
seema enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .