Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-Finance 19 RAMESH NAGAR LALIT APARTMENT JAI BHAVANI MATA ROAD VILLAGE TOWN AMBOLI VILLAGE CITY ANDHERI WEST MUMBAI | L1 | Accepted-Finance Tender accepted by competent authority | |
| 2 | L2₹47.2 L+₹2.7 L (6.12%)Accepted-Finance | L2 | Accepted-Finance Tender accepted by competent authority | |
| 3 | L3₹47.7 L+₹3.2 L (7.29%)Accepted-Finance 0 0 0 ABABAKPUR KANPUR NAGAR UTTAR PRADESH 209203 UDYAM UP 43 0068644 | KANPUR NAGAR | UTTAR PRADESH | 209203 | L3 | Accepted-Finance Tender accepted by competent authority | |
| 4 | Rejected-Technical 1 GANESH DARSHAN ADV SURVE MARG SANDHURST ROAD W MUMBAI 9 | MUMBAI | MAHARASHTRA | - | Rejected-Technical Rejected due to tender document not uploaded |
Tender Value
Refer Docs
EMD Value
₹1.0 L
Closing Date
30 Jun 2022, 11:00 amClosed
The Executive Engineer E, BSNL ED Mumbai
The Executive Engineer E BSNL Electrical Division 5 th Floor A Wing BSNL Admin Bldg Juhu Tara Road Santacruz West Mumbai 400054
Operation and Comprehensive Maintenance of EMS at Fountain Telecom Bldg I II CTO Bldg and IQ Byculla Mumbai
2022_BSNL_116724_1
NIT No. 04/EEE/BSNL/ED/MI/2022-23
Open Tender
Electrical Works
Item Rate
730 days
Mumbai
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Accounts Officer (F and A) BSNL
₹1.0 L
2 Aug 2022
23 May 2022
1 Jul 2022
23 May 2022
30 Jun 2022
23 May 2022
Amount
Comprehensive Maintenance of Electro- mechanical services including monitoring, managing round the clock operation of the Electro- mechanical services by deploying suitable automation arrangement/ sufficient no. of staff, etc. to maintain uninterrupted operation of EMS services as per given terms and conditions. The EMS is as per the size of services attached.
A] Operation & comprehensive Maintenance
Fountain I + Fountain II + CTO Bldg/IQ + Byculla IQ
2 x1500 KVA Transformer Sub Station i/c M.V. Panel, Capacitor Panel, L.T. Panel, Bustrunking etc.
2 x 3000 KVA Transformer Sub Station i/c M.V. Panel, Capacitor Panel, L.T. Panel, Bustrunking etc.
2 x 2000 KVA Engine Alternator with AMF panel &PLC logic automation .
L.T.Panels ( As per Size of Services )
Compound Lighting
Electrical Installation & Fittings in : Fountain Bldg -I : 4th Floor & Basement area Fountain Bldg II : 10th & 11th Floor area, Sub-station area & 2000 KVA DG Area CTO Building :- ( As per Size of Services ) Byculla Inspection Qtr and S/Qtrs
Fire Alarm and Fire Detection System and Fire Extinguishers in BSNL area of Fountain I, II and C.T.O.
2 x 5 TR and 3 x3 TR Ductable Split AC units in Data Centre of Fountain-I Bldg.
Water Pump sets at C.T.O. Bldg. ( As per size of Services )
Split /Window AC units i) 2x5 TR & 3x3 TR ductable split AC units ( 4th floor DATA Centre ) ii) 1.5 TR Split AC units : 31 Nos ( IQ Byculla - 15 Nos , CTO and FTB II IQ's - 11 Nos., 10th and 11th Floor WTR Power plant Rooms FTB-II - 5 Nos.) iii) 1.5 TR Window AC :- 05 Nos (At 10th and 11th Floor WTR Power Plant Room FTB-II )
B] For Operation Only
AC Package Plants i) 4x11 TR HPAC ( Data Center) ii) 2x15 TR HPAC ( Data Center) iii) 4x 7 TR HPAC ( FTN II , 11th floor) iv) 6x7 TR HPAC (FTN II , NIB ,11th floor) v) 1x7 TR HPAC (FTN II , 10th floor)
Note: 1. Contractor to take all steps to undertake preventive/special maintenance and testing to keep the system at optimum working condition. 2. In case of non compliances, recoveries shall be applicable as per relevent terms & conditions.
Servicing & Routine maintenance (B check) of 2000 KVA [M/s. Mitsubishi ] capacity of DG set complete with replacement of engine lube oil of 15 W 40 (seal pack of reputed make), replacement of by pass filter element,lube oil filter elements, fuel filter elements, radiator water by adding coolent (20 ltr Inhibitor Corrosion) , Cleaning of radiator fins, drain sediments from water separator, check inlet air restriction, check air piping, belt tensions i/c cleaning & dedusting of alternator, control panel, fuel tank, tightening & maintaining of all hose connections, electrical connections, battery connections etc & actual load testing of DG set after servicing etc as directed. ["B" check once in 12 months. ]
Supplying & fixing of fully charged 12 volt,180AH lead acid Maintenance Free battery for starting of 2000 KVA DG set complete with end sockets etc.as reqd. NOTE- 1) The battery(s) of each DG set shall be replaced once during currency of contract & agency shall consider rebate for old battery while quoting of rates.
VISHAL CONTRACT WORKS
M/s Satyam Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .