RequiredOEM Annual Turnover Bid to RA enabled No Note: 1. OEM Turn Over Criteria: The minimum average annual financial turnover of the OEM of the offered product during the last three years
Requiredending on 31st March of the previous financial year
Requiredshould be as indicated in the bid document. Documentary evidence in the form of certified Audited Balance Sheets of relevant periods or a certificate from the Chartered Accountant/Cost Accountant indicating the turnover details for the relevant period shall be uploaded with the bid. In case the date of constitution/incorporation of the OEM is less than 3 year old
Requiredthe average turnover in respect of the completed financial years after the date of constitution shall be taken into account for this criteria. Fixed Clean Agent Gas Based Fire Suppression System ( 5 pieces ) Technical Specifications * As per GeM Category Specification 1/6 Specification Specification Name Values Bid Requirement (Allowed Values) GENERIC Clean Agent Gas based Fire Suppression System suitable upto 2 metre cube volume Designed to fight fires that occur in the enclosed space of electric panels/closed cabinets/Racks The system's split second detection and activation ensures that the fires are killed in the nascent stage inside the most vulnerable spaces * Types of Electrical or Server Cabinets (Construction) Open Cabinet with natural Airflow * Type of Clean agent with zero ODP(ozone depleting potential) as per NFPA 2001 to be used for fire suppression - * Clean Agent listing UL * CONSTRUCTIONAL Container (Containing the clean agent) BS EN 3-8 * Electrical non conductive Clean Agent Type Yes * Clean agent Capacity of cylinder in Kg 2 * Length of Heat Sensing Tube (HST) made of special modified polymide (PA) in (meter) approved by LPCB/UL LISTED 10 * Internal Diameter of Heat Sensing Tube 4mm * Out side diameter of heat sensing tube 6mm * Prepressurised Tube Heat Sensing Tubing should be pressureized with dry nitrogen gas confirming to IS: 1747 and connected to an extinguishing agent container via a pressure release valve. * Pressure Valve Direct low pressure type with inbuilt * 2/6 pressure gauge
Requiredintegrated ball valve for open/close within the valve body. Reed switch to monitor the valve position using the reed switch relay to indicate valve open/closed position With * Number of outlets to connect the heat sensing tube Two * Valve operation Pneumatic * Monitoring Panel An audio visual monitoring panel Micro controller based design to check the health of the system and the pressure in the tube * Power back up for Monitoring Panel 12V
Required7.2 Ah SMF batteries (2 Nos) * Indication on Monitoring Panel Ac Power ON
Requiredsystem ON
Requiredsystem discharge
Requiredvalve closed/open
RequiredPressure Healthy
RequiredBattery Low indication by LED indicator * Third Party Intigration facility to intigrate with other fire safety device like smoke detection system panel etc Yes * Electric Buzzer 50 dB piezo electric buzzer * Pressure switches to sense the drop in pressure Yes * Option to connect upto 4 systems in one panel Yes * If not connect 4 system in one panel please declare - * Suitable valve for closing & releasing Yes * Straight connectors elbow connectors/T connectors for connecting HST in case wherever required Yes * 3/6 End of line adapter Yes * End of line plug Yes * Conventional electric sounder suitable to operate between temperature -20⁰C to +60⁰C
Requiredwith a sound of minimum 60 decibles with variable tones in Red Colour and IP-66 Rated With * PERFORMANCE Ozone Depleting Potential Zero * HST Tube type multi layer and UV protected * Max Working Pressure 20 Bar * Burst Pressure at 20 ⁰C 108 * Operating Temperature range shall be -20⁰ C to 60⁰ C -20⁰ C to 60⁰ C * System operating pressure 15 bar * CERTIFICATION Complete system testing and certification LPCB Standard LPS 1666:Issue 1.0 LPCB Standard LPS 1666:Issue 1.0 Test report of the Heat sensing tube Yes * Marking of OEM Supplier Name & year of production on the tube Yes * Valve Certification TPED certificate for valve in conformity to EN ISO 10297:2006/Pi/CE Marked * For panel having ventilation or exhaust fan adequate safety factor for clean agent as per LPS 1666 to be provided Yes * System operation and maintenance manual to be submitted along with the supplies Yes * Design lifespan period (Min 5 years) 10 * Test Report No and - * 4/6 Date Name and Address of the Lab - * Test Reports to be furnished to the buyer on demand Yes * Warranty of the complete system (years) 2 2 * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.