Directorate of Municipal Administration
Providing Electrification work to MRF unit at Kalkunike in Hunsur CMC Limit
DMA/2025-26/EL/WORK_INDENT48848
DMA/2025-26/EL/WORK_INDENT48848
Open
Electrical
Electronic Documents, First(One Cover)
DMA City Municipal Council Hunasuru
₹500
₹37,500
4 Sept 2025
4 Sept 2025
20 Sept 2025
Providing Electrification work to MRF unit at Kalkunike in Hunsur CMC Limit
RCC Pole - 9 Mtr Long, 145 Kg WL (Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as per IS-785 (Page 3, Item No. 1.01 of ESCOM SR)
11 kV, Horizontal Cross Arm - Mild Steel (MS) (Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018) (Page 3, Item No. 2.01 of ESCOM SR)
11 kV, Special 3 Pin Cross Arm - MS (Dwg No. BESCOM/GM/QS&S/03 Dtd 24.11.2018) (Page 3, Item No. 2.03 of ESCOM SR)
LT 2 Pin Cross Arm - MS (Dwg No. BESCOM/GM/ QS&S/32 Dtd 24.11.2018) (Page 4, Item No. 2.06 of ESCOM SR)
Anticlimbing Device. GI Barbed wire (12 Mtr/Kg) (Page 4, Item No. 4.02 of ESCOM SR)
RCC Pole Clamp - MS (Dwg No. BESCOM/GM/QS&S/30 Dtd 24.11.2018) (Page 4, Item No. 5.01 of ESCOM SR)
Guy Clamp - MS (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018) (Page 5, Item No. 5.09 of ESCOM SR)
Turn Buckle (GI) (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018) (Page 5, Item No. 5.11 of ESCOM SR)
Anchor Rod using 12 mm rounds/Guy Rod - MS (Dwg No. BESCOM/GM/QS&S/07 Dtd 24.11.2018) (Page 5, Item No. 5.12 of ESCOM SR)
MS Fish Plate . (Page 5, Item No. 5.14 of ESCOM SR)
Insulator as per IS-1445 for Ceremic, IS 7935 for GI Pin, IEC-61109 for Polymeric. 1.1 kV Polymeric Pin Insulator. (Page 5, Item No. 6.05 of ESCOM SR)
Insulator as per IS-1445 for Ceremic, IS 7935 for GI Pin, IEC-61109 for Polymeric. 11 kV, 5 kN Composite/Polymeric Pin Insulator (24 mm dia FRP Rod) . (Page 5, Item No. 6.06 of ESCOM SR)
Insulator as per IS-1445 for Ceremic, IS 7935 for GI Pin, IEC-61109 for Polymeric. No. 15 Strain Insulator. (Page 5, Item No. 6.08 of ESCOM SR)
Insulator as per IS-1445 for Ceremic, IS 7935 for GI Pin, IEC-61109 for Polymeric. DISC Insulator 45 kN Porcelain. (Page 5, Item No. 6.09 of ESCOM SR)
ACSR Conductor as per IS-398 (Part - 2/1996) Rabbit ACSR
(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM. (Page 5, Item No. 7.02 of ESCOM SR)
Guy Wire & GI Wire as per IS-2141: 7/10 SWG Guy Wire
(7/3.251 mm Dia), Std Wt: 680 Kg/KM. (Page 5, Item No. 8.01 of ESCOM SR)
PG Clamp: Rabbit to Rabbit. (Page 6, Item No. 9.02 of ESCOM SR)
PG Clamp Rabbit to Insulated Wire: 95 Sqmm (Dwg No. BESCOM/GM/QS&S/43 Dtd 24.11.2018). (Page 6, Item No. 10.01 of ESCOM SR)
Supplying of Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014. 63 kVA, Aluminum Wdg, Star 2 (5 Star). OPEN BUSHING TYPE. (Page 7, Item No. 12....
1.1 KV Class HR (Heat Resistant) PVC Insulated & UnSheathed Aluminium Wires Multistrand Single Core Lead wires as per IS 694: 2010 PVC Wire - 95 Sqmm Al Wt: 25 Kg, Total Wt: 36 Kg/100 Mtr Coil(Page 2...
Supply of LT Protection Kit (Dwg No. BESCOM/GM/ QS&S/10 Dtd 24.11.2018) (Page 9, Item No. 17.01 of ESCOM SR)
Supply of LT Distribution Box as per IS-13947 Part 1&2: LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) (Dwg No. BESCOM/GM/QS&S/58 Dtd 24.11.2018) (Page 9, Item No. 18.01 of ESCOM SR)
Supply of Lightning Arrester as per IEC-60099-4: 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR (Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007)(Page 9, Item No. 19.01 of ES...
Supply of HG Fuse Unit as per IS-5350 Part-2:11 kV, HG Fuse Unit with Solid Core Insulator (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018) (Page 9, Item No. 20.01 of ESCOM SR)
Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long: For 25/63/100 kVA 4/5 Star Rated Transformer on RCC Pole - 9 Mtr Long, 145 Kg WL - GI. (Page 9, Item No. 20.03 of ESCOM SR)
GOS as per IS-9921, IS-1977: 11 kV, 200 Amps Single Break GOS
(Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018) (Page 11, Item No. 24.01 of ESCOM SR)
Supply of H - Frame Set for fixing 11 kV, 200 Amps Single Break GOS - (For DP structure for providing New GOS for sectionalisation) - MS(Page 11, Item No. 24.06 of ESCOM SR)
Supply of Fixed and Moving contacts with B&N for 11 kV, 200 Amps GOS (1 Fixed & 1 Moving contacts each) (Page 11, Item No. 24.08 of ESCOM SR)
Supply of Insulated GOS Operating Rods (Page 12, Item No. 24.10 of ESCOM SR)
Supply of DOLO Cutout as per IS-9385, Part-1 to 3:11 kV, DOLO Cutout Conventional to Erstwhile KEB Specification. (Page 12, Item No. 25.01 of ESCOM SR)
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975: 70 Sqmm...
1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975: 25 Sqmm...
Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573, Epoxy Type, 25 Sqmm, 4 Core. (Page 14, Item No. 34.06 of ESCOM SR)
Suppy of 1.1 kV Class HR (Heat Resistant) PVC Insulated & Sheathed Aluminium Single Core Lead wires as per IS-694: 2010. PVC Wire - 6 Sqmm Weight per 100 Mtr Coil: 3.5 Kg (Page 11, Item No. 48.03 of ...
Rod Earthing: Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected ...
Rod Earthing: Bentonite clay slurry for earthing in 50 Kg Bag. (Page 23, Item No. 51.05 of ESCOM SR)
CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 Port UNIDIRACTIONAL (Used for HT Installation, LT Metering Cubicle (50-150 KW)) (Page 23, Ite...
Meter Protection/Tamper Proof Box . Meter Protection/Tamper Proof box with busbar for LT 3 Ph with CT Ratio 50/5A, 1.0 Accuracy Class. (Page 25, Item No. 55.01 of ESCOM SR)
Sheet Metal/Deep Drawn Street Lighting Metering Box with Automatic Control Swith, Contactors with Single Phase 5-30 Amps meter & 50/5A CT (Page 25, Item No. 55.09 of ESCOM SR)
Heavy Duty Copper Terminal Long Barrel. 25 Sqmm Copper Terminal, Apprx Wt: 11 Gm. (Page 26, Item No. 59.01 of ESCOM SR)
Heavy Duty Copper Terminal Long Barrel. 70 Sqmm Copper Terminal, Apprx Wt: 26 Gm. (Page 26, Item No. 59.04 of ESCOM SR)
Heavy Duty Copper Terminal Long Barrel. 95 Sqmm Copper Terminal, Apprx Wt: 26 Gm. (Page 26, Item No. 59.05 of ESCOM SR)
Heavy Duty Copper Terminal Long Barrel. 120 Sqmm Copper Terminal, Apprx Wt: 26 Gm. (Page 26, Item No. 59.06 of ESCOM SR)
For Distribution Transformer Centre (DTC) MS Box for housing the ETV Meter 3 Phase 4 Wire 5 Amps, with associated LT CT 0.5
Accuracy Class, ring type, with wiring Clamps, B&N and all other accessorie...
SMC metering box as above . With CT Ratio 100/5 for 50/63 kVA DTC. (Page 29, Item No. 64.07 of ESCOM SR)
GPRS Modem with Accessories. (Page 24, Item No. 53.13 of ESCOM SR)
Spiral Earth Electrode . (Page 4, Item No. 2.16 of ESCOM SR)
Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/ PSCC supports as per approved Drawing.Ordinary Soil. (Page 43, Item No. 1.1.1 of ESCOM SR)
Digging of Pit for GUY SET.Ordinary Soil. (Page 44, Item No. 1.7.1 of ESCOM SR)
Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth . (Page 44, Item No. 2.02 of ESCOM SR)
Providing Spiral Earth Electrode type earthing (without charcoal, salt etc.,). (Page 44, Item No. 2.08 of ESCOM SR)
Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transform...
Fixing of 2 Pin cross arm with Insulator and Braces fixing. (Page 45, Item No. 5.01 of ESCOM SR)
Fixing of Fixing of 4 Pin cross arm with Insulator and Braces fixing. (Page 45, Item No. 5.02 of ESCOM SR)
Fixing of V-Shape/Horizontal cross arm including Single Top Support Brace and Insulator fixing. (Page 45, Item No. 5.03 of ESCOM SR)
Fixing of HT/LT Single Top Support. (Page 45, Item No. 5.06 of ESCOM SR)
Fixing of . GI Barbed Wire (12 Mtr) (Page 45, Item No. 5.06 of ESCOM SR)
Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT). (Pag...
Stringing of Rabbit ACSR, binding of conductor on each insulator and dead ending on strain or disc/strain insulator by means of clamps.. (Page 46, Item No. 6.02 of ESCOM SR)
Erection of 25 to 63 kVA Transformer on Transformer Structure. (Page 46, Item No. 8.01 of ESCOM SR)
Providing GI Pipe Earthing for Lightning Arrester, Transformer Neutral and Transformer Metal parts (Excluding digging of pits). (Page 46, Item No. 8.01 of ESCOM SR)
Fixing Metering Box for housing the ETV Meter 3 Phase 4 Wire along with CT's, Meter & wiring for DTC. 25/63 kVA TC. (Page 47, Item No. 11.01 of ESCOM SR)
Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring. (Page 48, Item No. 13.01 of ESCOM SR)
Fixing of GOS including wiring (11 kV Single Break 200 Amps). (Page 48, Item No. 13.02 of ESCOM SR)
Fixing of 3 Nos Lightning Arrestor including wiring. (Page 48, Item No. 13.06 of ESCOM SR)
Fixing of GPRS Modems with Accessories. (Page 49, Item No. 14.04 of ESCOM SR)
Fixing of Sheet Metal/Deep Drawn Street Lighting Metering Box with Automatic Control Swith, Contactors with Single Phase 5-30 Amps Meter & 50/5A CT including wiring. (Page 49, Item No. 15.01 of ESCOM...
Fixing of LT Metering Box with clamping arrangement for mounting on the Transformer structure with necessary terminal strip and CT mounting arrangement for housing the ETV Meters and connecting to the...
Fixing of LT Protection Kit. (Page 49, Item No. 15.03 of ESCOM SR)
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. LT Cable, 35 to 95 Sqmm. (Page 52, Item No. 21.06 of ESCOM SR)
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. LT Cable, 2.5 to 25 Sqmm. (Page 52, Item No. 21.05 of ESCOM SR)
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capa...
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage curr...
Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board. (Page 18, Item No. 5.22 of PWD Elec SR Part-3)
Supplying, fixing and wiring 0 to 1500A CT operated AC analog type Ammeter without CT (Page 18, Item No. 5.26 of PWD Elec SR Part-3)
Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. (Page 19, Item No. 5.34 of PWD Elec SR Part-3)
Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power...
Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator wh...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5 Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wir...
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire...
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire...
Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using...
Supplying heavy gauge PVC conduit pipe ....... dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive pasteetc , and fixing using inverted wood plugs in case of...
Supplying heavy gauge PVC conduit pipe ....... dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive pasteetc , and fixing using inverted wood plugs in case of...
Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/N...
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing m...
Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greaterthan 80. Power Input: 220-240V@ 5...
Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing,with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degre...
Supply of LED Streetlight luminaire with pressure die cast aluminium housing ody for optimal thermal dissipation. Lamp compartment comprising of anti lare clear diffuser with Injection moulded polycar...
Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / ...
Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. (P.No.56, I.No:13.5 PWD Elec SR Pa...
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. ...
Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped...
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capa...
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capa...
Supplying of Switch disconnector fuse unit (TPN) HRC type (but
without HRC fuses). With AC-23A duty and as per IS- 13947. 63 A.
(I.No.5.8.1, P.No.15, PWD Elec SR Part-3)
Supplying and fixing HRC fuse units base on existing switch /panel board. 32 to 63 A . (I.No.5.9.2, P.No.15, PWD Elec SR Part-3)
Supplying and fixing HRC fuse link on existing switch fuse base with W loss as per IS-13703.upto 63 A. (I.No.5.10.1, P.No.15, PWD Elec SR Part-3)
Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 100 A. (I.No.5.12.2, P.No.15, PWD Elec SR Part-3)
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of O...
Supplying and fixing of Shunt trip suitable for MCCB.CBCT (I.No.5.16, P.No. 17, PWD Elec SR Part-3)
Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 12" x 12" x 3" ...
Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, s...
GI/Copper strips for grounding connections, using necessary fixing
materials as required. 50 x 6 mm GI strip. (I.No. 12.58.5, P.No.55, PWD Elec SR Part-3)
Supplying and fixing of metal clad industrial plugs and sockets. 3pole+earth 440V PLUG, 32A. (I.No. 3.13.4, P.No. 9, PWD Elec SR Part-3)
Supplying and fixing of metal clad industrial plugs and sockets. 3pole+earth 440V SOCKET, 32A. (I.No. 3.13.8, P.No. 10, PWD Elec SR Part-3)
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .