| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC 15 EMERSON ROAD DANAPUR CANTT PATNA 801101 | PATNA | PATNA | BIHAR | 801101 | L1 | Accepted-AOC QUOTED RATES ARE REASONABLE AND ACCEPTED | |
| 2 | L2₹12.3 L+₹1.0 L (9.17%)Rejected-Finance ROOM NO 281 GANESH MARUTI NAGAR CAPTAIN PRAKASH PETHE MARG BACKBAY BUS DEPOT CUFFE PARADE MUMBAI 400005 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance QUOTED RATES ARE REASONABLE AND ACCEPTED | |
| 3 | L3₹14.2 L+₹2.9 L (25.7%)Rejected-Finance KAUSALY KUNJ KORHAR ANANDPUR CAMP BIHTA PATNA 801103 | BIHTA | PATNA | BIHAR | 801103 | L3 | Rejected-Finance QUOTED RATES ARE REASONABLE AND ACCEPTED |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
18 Jul 2024, 6:00 pmClosed
GE AF BIHTA
AIR FORCE STATION BIHTA 801103
REPAIR/MAINT OF DG SET, AMF PANEL, FIRE ALARM SYSTEM, REPLACEMENT OF UNSV UG CABLE AND CONNECTED WORKS AT AF STN BIHTA
2024_MES_661502_1
8424/BHT/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
BIHTA
Class E and above and category b(i)
6 documents required · 6 mandatory
₹500
GE (AF) Bihta
₹30,000
Yes
4 Dec 2024
22 Jun 2024
25 Jul 2024
22 Jun 2024
18 Jul 2024
6 Jul 2024
24 Jun 2024 - 29 Jun 2024
Amount
Inspection, maintenance and servicing including Alternator of connected DG set 75 KVA make Kirloskar excluding AMF panel installed at AF Net site 1 for routine check up of the engine for the smooth functioning and carrying out the complete servicing as per the Manufacturers instructions, all as specified and directed by Engr-in-Charge. A'Check (Item Nos. 1 to 12). (i) Check Engine oil level and topping up as and when required [Engine oil will be measuered paid separately] (ii) Check Engine Coolant oil level if required topping up.[Coolant oil measured and paid separately]. (iii) Check Belts if there is belt slippage adjust or replace. (iv) Check oil bath cleaner oil level. (v) Check Exhaust System for leakage and rectification. (vi) Drain sediment and cleaning from Fuel filter & Fuel Tank. (vii) Check dry type air filter element and clean or replace [ Air filter element shall be measuered paid seperately].
All as per item no. 1 above but DG set of capacity 75 KVA, make Kirloskar installed at AF Net Site 2, complete all as specified and directed by Engr-in-Charge.
All as per item no. 1 above but DG set of capacity 62.5 KVA, make Kirloskar installed at pump house No. 3, complete all as specified and directed by Engr-in-Charge.
All as per item no. 1 above but DG set of capacity 40 KVA, Make Cummins Jakson installed at Pump House No. 2, complete all as specified and directed by Engr-in-Charge.
All as per item no. 1 above but DG set of capacity 40 KVA, Make Sonilika installed at Tropo perimeter Sub Station No. 2, complete all as specified and directed by Engr-in-Charge.
All as per item no. 1 above but DG set of capacity 40 KVA, Make Cummins Jakson installed at ATC sub station (Alt.), complete all as specified and directed by Engr-in-Charge.
All as per item no. 1 above but DG set of capacity 40 KVA, Make Sonilika installed at OTES, compete all as specified and directed by Engr-in-Charge.
All as per item no. 1 above but DG set of capacity 40 KVA, Make Cummins Jakson installed at ATC Sub Station, complete all as specified and directed by Engr-in-Charge.
All as per item no. 1 above but DG set of capacity 25 KVA, Make Cummins Jakson Installed at Main Guard room, complete all as specified and directed by Engr-in-Charge.
All as per item no. 1 above but DG set of capacity 25 KVA, Make Cummins Jakson Installed at Sub Guard room, complete all as specified and directed by Engr-in-Charge.
All as per item no. 1 above but DG set of capacity 15 KVA, Make Cummins Jakson Installed at Sub station No. 2 (Tropo), complete all as specified and directed by Engr-in-Charge.
All as per item no. 1 above but DG set of capacity 15 KVA, Make Cummins Jakson Installed at 10 ASC, complete all as specified and directed by the Engr-in-Charge.
Inspection, maintenance and servicing of DG set 75 KVA, installed at AF Net site-1, including Alternator, excluding AMF panels connected to DG sets for routine check up of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturer's instructions including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., complete all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
All as per item no. 13 above but DG set of capacity 75 KVA installed at AF Net Site-2, complete all as specified and directed by Engr-in-Charge.
All as per item no. 13 above but DG set of capacity 62.5 KVA installed at pump house No. 3, complete all as specified and directed by Engr-in-Charge.
All as per item no. 13 above but DG set of capacity 40 KVA installed at Pump House No. 2, complete all as specified and directed by Engr-in-Charge.
All as per item no. 13 above but DG set of capacity 40 KVA, installed at Tropo perimeter Sub Station No. 2, complete all as specified and directed by Engr-in-Charge.
All as per item no. 13 above but DG set of capacity 40 KVA, installed at ATC sub station (Alt.), complete all as specified and directed by Engr-in-Charge.
All as per item no. 13 above but DG set of capacity 40 KVA, installed at OTES, complete all as specified and directed by Engr-in-Charge.
All as per item no. 13 above but DG set of capacity 40 KVA, installed at ATC Sub Station, complete all as specified and directed by Engr-in-Charge.
All as per item no. 13 above but DG set of capacity 25 KVA, Installed at Main Guard room, complete all as specified and directed by Engr-in-Charge.
All as per item no. 13 above but DG set of capacity 25 KVA, Installed at Sub Guard room, complete all as specified and directed by Engr-in-Charge.
All as per item no. 13 above but DG set of capacity 15 KVA, Installed at Sub station No. 2 (Tropo), complete all as specified and directed by Engr-in-Charge.
All as per item no. 13 above but DG set of capacity 15 KVA, Installed at 10 ASC, complete all as specified and directed by Engr-in-Charge.
Supply and filling engine oil SAE 20W-40W, complete all as specified and directed by Engr-in-Charge.
Supply & filling radiator coolant, complete all as specified and directed by Engr-in-Charge.
Servicing & Maintenance of AMF panels pertains to 75 KVA DG SET, installed at AF Net site 1 for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like cleaning & servicing all contact points etc. complete all as directed by Engr-in-Charge. Note :- Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc., shall be measured & paid separately "UNDER SUPPLY ONLY RATES".
All as per item no. 27 above but DG set of capacity 75 KVA, installed at AF Net Site No.- 2, complete all as specified and directed by Engr-in-Charge.
All as per item no. 27 above but DG set of capacity 62.5 KVA, installed at pump house No. 3, complete all as specified and directed by Engr-in-Charge.
All as per item no. 27 above but DG set of capacity 40 KVA, installed at Pump House No. 2, complete all as specified and directed by Engr-in-Charge.
All as per item no. 27 above but DG set of capacity 40 KVA, installed at Tropo perimeter Sub Station No. 2, complete all as specified and directed by Engr-in-Charge.
All as per item no. 27 above but DG set of capacity 40 KVA, installed at ATC sub station (Alt.), complete all as specified and directed by Engr-in-Charge.
All as per item no. 27 above but DG set of capacity 40 KVA, installed at OTES, complete all as specified and directed by Engr-in-Charge.
All as per item no. 27 above but DG set of capacity 40 KVA, installed at ATC Sub Station, complete all as specified and directed by Engr-in-Charge.
All as per item no. 27 above but DG set of capacity 25 KVA, Installed at Main Guard room, complete all as specified and directed by Engr-in-Charge.
All as per item no. 27 above but DG set of capacity 25 KVA, Installed at Sub Guard room, complete all as specified and directed by Engr-in-Charge.
All as per item no. 27 above but DG set of capacity 15 KVA, Installed at Sub station No. 2 (Tropo), complete all as specified and directed by Engr-in-Charge.
All as per item no. 27 above but DG set of capacity 15 KVA, Installed at 10 ASC, complete all as specified and directed by Engr-in-Charge.
Removing the self starter, 12 Volt DC from the engine of 15 to 75 KVA DG sets and taking to work shop for rewinding of armature / field including replacement of brush and bush and refixing the same to the engine and testing, complete all as specified and directed by Engr-in-Charge.
Supply only 12 V DC stopping solenoid suitable for 15 to 75 KVA DG sets, complete all as specified and directed by Engr-in-Charge.
Supply only Water Temp. gauge with adapter, complete all as specified and directed by Engr-in-Charge.
Supply only Oil Temp. gauge with adapter, complete all as specified and directed by Engr-in-Charge.
Supply only Oil pressure guage with pipe, complete all as specified and directed by Engr-in-Charge.
Supply only AC / DC Timer, complete all as specified and directed by Engr-in-Charge.
Supply only PLA Relay with Base, complete all as specified and directed by Engr-in-Charge.
Supply only Voltmeter DC, complete all as specified and directed by Engr-in-Charge.
Supply only Ammeter DC, complete all as specified and directed by Engr-in-Charge.
Supply and fixing Battery 12 Volts 80 AH complete all as specified and directed.
Supply and fixing Battery 12 Volts 100 AH complete all as specified and directed.
Taking out unserviceable power contactor and Supply and fixing power contactor suitable for AMF panel up 40 to 75 KVA, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs Air filter element as per existing make for 62.5 to 75 KVA DG Set, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs Air filter element as per existing make for 40 KVA DG Set, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in repairs Air filter element as per existing make for 15 to 25 KVA DG Set installed, complete all as specified and directed by Engr-in-Charge.
S&F dynamo fan belt set suitable for DG Set of 62.5 to 75 KVA, complete all as specified and directed by Engr-in-Charge. Make : Kirloskar (2.00 to 2.50 for belts.)
S&F dynamo fan belt set suitable for for DG Set 15-40 KVA, complete all as specified and directed by Engr-in-Charge.
S&F water pump suitable for 62.5 to 75 KVA DG Set, complete all as specified and directed by Engr-in-Charge.
S&F water pump suitable for for DG Set of 40 KVA, complete all as specified and directed by Engr-in-Charge.
S&F water hose pipe set with clamps suitable for 62.5 - 75 KVA DG Set, complete all as specified and directed by Engr-in-Charge.
S&F water hose pipe set with clamps suitable for 40 KVA DG Set, complete all as specified and directed by Engr-in-Charge.
S&F Relay suitable for Kirloskar Make DG Set 62.5 to 75 KVA (existing type & voltage -24/12 Volts) in AMF panel and making connections including testing, complete all as specified and directed by Engr-in-Charge.
S&F Relay suitable for Kirloskar Make DG Set 40 KVA (existing type & voltage -240 Volts AC) in AMF panel and making connections including testing, complete all as specified and directed by Engr-in-Charge. Make: L&T , Siemens or equivalent.
S&F Auxiliary contact suitable for DG Set upto 75 KVA (Existing type) with logic units, complete all as specified and directed by Engr-in-Charge. Make: L&T/Legrand/ Havells/ Siemens.
S&F Main contactors four pole, 220 Volt suitable for upto 75 KVA DG set of existing model, complete all as specified and directed. Make- L&T Havells, legrand etc.
S&F SMPS unit suitable for DG Set 15 to 40 KVA DG Set for battery charging including making connections and testing etc., complete all as specified and directed.
S&F SMPS unit suitable for DG Set 62.5 to 75 KVA DG Set for battery charging including making connections and testing etc. complete all as specified and directed.
Material & Labour and checking for fire alarm system including rectification of loop, smoke detector, hooter, mother board and MCP and if necessary armoured wire of 1.5 sqmm 2 core need to be supplied, complete all as specified and directed.
Supply and fixing of ON load change over switch having current rating 200 Amps, 415 volts, 50 Hz, 4 pole with steel sheet encls conforming to IS :13947(part-3), IEC : 60947-3, complete all as specified and directed.
Dismantling of upper portion of Diesel Engine upto 75 KVA, Water cooled, Turbo charged 1500 RPM vertical type installed at AF station Bihta and Top over hauling and repair / servicing of engine including taking out radiator, fuel pump, hydraulic governors, lub oil pumps, water pump, turbo charger etc., assembling engine after replacement of UNSV defective parts, complete all as specified and directed. Note:-Cost of defective parts included in quoted rate.
M&L for grinding, cutting of cylinder heads including inserting of new valves (Exaust and inlet) valve shafts guide, called valve spring etc., complete all as specified and directed. Note:-Cost of Spares as required shall be deemed included in quoted rate.
Repair, overhauling and calibration of fuel pump complete with replacement of worn out parts such as bearings plunger, impeller and oil seal etc., including calibration of injector and refixing fuel injector pump and injector including testing, complete all as specified and directed by Engr-in-charge.
Supply and fixing on wall 'DO AND DON'T' chart for electric installation and made out of plastic based paper with glass cover and aluminium frame of size 0.80 mtrs x 1.00 mtrs including two numbers clamp for hanging arrangements with instructions written in Hindi or English language, complete all as specified and directed by Engr-in-charge.
Supply and fixing AVR, complete all as specified and directed by Engr -in-Charge.
Supply and fixing, testing AMF panel of capacity 40 KVA to 75 KVA DG set, complete all as specified and directed by Engr -in-Charge.
M&L for servicing of existing unsv solar water heater and collector panel of capacity 100 LPD of any Make with electric back up system after disconnecting the existing water supply / water connection from any height of the building / ground, including stripping out the hot water vessel by taking out, outer cover, insulating materials etc. and continuous brazing / welding of the inner container where required for arresting leakages including replacemnt of defective / worn out spare parts etc. and re-assembling the system connecting the water / electrial connections and testing, complete upto the satisfaction of Engr-in-Charge.
-ditto- All as per Ser item No. 76 above but for solar water heater of capacity 200/300 LPD, complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED luminaries (>120 Lumens/watt) 600 mm x 600 mm, 30 watt (LCTLRNE-30-FO-CDL) suitable for 230 volts, 50 HZ AC supply recessed type with high efficiency PMMA diffuser soft glair free light complete with driver, holder and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size from ceiling rose including taking down old one, complete all as specified and directed by Engr-in-charge.
M&L for maintenance of electrically operated overhead travelling crane (EOT) double girder type of capacity 2.5 ton comprising of electric motor for long travel, hoist motion, creeping micro speed and electrical control panel consisting of MCCBs / main switches, step down transformer, contactors, HRC fuses & mechanical wire rope with drum, brake unit, gear boxes, oil levels, motor bed ends, electrical control cables etc. throughout the time period of the contract comprising of material, labour and T&P for routine, periodical, preventive maintenance or breakdown repair to make EOT crane functional at all time, complete all as specified and directed by the Engr-in-charge.
Note: (i) All lubricants including Gear Oil 80W90, Fine quality Grease and Welding work required for maintenance of cranes is inclusive in this items. The contractor shall check for any malfunctioning of the cranes during preventive maintenance. Preventive maintenance to be performed at least thrice in the period of Contract, the contractor shall also be liable for maintenance and repair jobs as per fault / defect occurrence without any extra cost. (ii) This item includes unlimited call response from contractor. Minor and Major break-down calls shall be attended within 12 hours from the time of intimation and Crane shall be made operational within 24 hours and 72 hours respectively without any extra charge. (iii) The maintenance of crane throughout the contract period shall be responsibility of the contractor and the bidders are advised to visit the site prior to bidding.
All as per item no. 79 above but of capacity 0.5 Ton, complete all as specified and directed by Engr-in-Charge.
Supply and fixing of conventional fire alarm panel of 16 zones which consists of display board and provision of autodials as approved, complete all as specified and directed by Engr-in-charge.
Supply and fixing of battery, 12V 8 AH for fire alarm panel of 16 zones, complete all as specified and directed by Engr-in-charge.
Supply, Laying, connecting and testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade laid in trenches, floors, ducts passing through pipe for road crossing etc., including taking down old UNSV cable of any size, complete all specified and directed of following sizes : - Note:- (excavation, earth work, brick protection sand cushioning and GI pipe etc shall be measured & paid for separately)
Cross sectional area 50 Sqmm, 3 ½ core.
Cross sectional area 70 Sqmm 3 ½ core.
Cross sectional area 95 Sqmm 3 ½ core.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out under ground cable / erection of poles, stays etc., complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick, complete all as specified and as directed.
Removing excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above the starting point, complete all as specifiedand directed.
M&L for laying of bricks sub class ‘B’ old size laid flat perpendicular to the direction of cable for protection of cable, complete all as specified and directed.
M&L for sand cushioning for cable with river washed sand and punning to provide required cover as per SSR Part –I, complete all as specified and directed.
M&L for PCC 1:3:6, type C-2 using 40 mm graded aggregate mechanically crushed stone for mass filling in stay pits and pole foundation, complete all as specified and directed.
Supply & fixing GI tubing of sizes 80 mm light grade on poles, under floors, road crossing etc. all as required at site, complete all as specified and directed by Engr-in-Charge.
ARTI ENTERPRISES (BID ID -3057465)
SANJAY CONSTRUCTION COMPANY (BID ID -3064741)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .