Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹31.4 L
Closing Date
28 Aug 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
BEDASHRUTI DAS
RHQ KOLKATA
The scope of work covered under this Package Control & Protection system up gradation with SAS based CRP and Replacement of 400KV & 220 KV switchyard equipment,Erection hardware,Auxiliary system with provision for new control room building and other up gradation at Malda SS of ER-2 under ADDCAP CTS 19-24 Budget as detailed in Bidding Documents.
ER-II/KOL/CS/I-3156/RFX-5002002271
Open
Services
Works
POWERGRID MALDA SUB-STATION
₹31.4 L
29 Jul 2022
29 Jul 2022
28 Aug 2022
29 Jul 2022
27 Aug 2022
29 Jul 2022
400KV Equipment
3000A, 50kA, Pantograph isolator (3 phase)with one earth switch (Tandem arrangement) along with suitable bus conncetor as per TS.
3000A, 50kA, Pantograph isolator (3 phase) without Earth switch (Tandem arrangement) along with suitable bus conncetor as per TS.
3000A, 50kA DBR isolator (3 phase) with 2 Earth switch along with suitable bus conncetor as per TS.
Supply of standard pipe structure for Pantograph Isolator (3 phase) for 400 KV
Supply of standard pipe structure for DBR Isolator (3 phase) for 400 KV
FOUNDATION BOLT 28 MM DIA
220KV Equipment
1600A,40kA DBR isolator ( 3 phase) with 01 earth switch
1600A, 40kA HCB isolator (3 phase) without earth switch (Tandem arrangement)
1600A, 40kA DBR isolator (3 phase) with 2 earth switch
1600A, 40kA DBR isolator (3 phase) without earth switch (Tandem arrangement)
Supply of BPI suitable for 220 KV.
Supply of 40 MM MS Rod for main earthmat as per requirement
Supply of standard pipe suitable structure for DBR / HCB Isolator ( 3 phase) for 220 KV.
Erection Hardware for 400kV system as per scope of work and TS
Erection Hardware for 220kV system as per scope of work and TS
FOUNDATION BOLT 28 MM DIA
SUBSTATION AUTOMATION SYSTEM (including requirement for substation Auxiliaries)
Complete Substation Automation System for the following 400kV bays as per Technical Specification and Scope of work:
400kV Line bays
400kV Transformer bays
400kV TBC bays
400kV BC bays
400kV non-switchable line reactor bay
Complete Substation Automation System for the following 220kV bays as per Technical Specification and Scope of work:
220kV Line bays
220kV Transformer bays
220kV TBC bays
220kV BC bays
Complete substation automation system for controlling and monitoring of auxiliary system including BCU as per TS
Control & Relay Panels (400 KV) (SAS based)
400kV CB relay panels with A/R (with automation)
400kV CB relay panels without A/R (with automation) as per TS.
400kV Line Protection Panel (with automation)
400kV Transformer protection panel (HV & MV sides) with automation
Low Impedance type distributed Bus bar protection (Duplicated) for complete 400 KV Switchyard with automation
Time synchronisation equipment
33 KV Protection panel for Transformer (with automation)
Control & Relay Panels (220kV) (SAS based)
220kV Circuit Breaker Relay Panel with auto reclose (with automation)
220kV Circuit Breaker Relay Panel without auto reclose (with automation)
220kV line protection panel (with automation)
220kV transformer protection panel (for both HV & MV side)-(with automation)
Low Impedance type distributed Bus bar protection for complete 220 KV Switchyard, single busbar protection with automation
SUBSTATION AUXILIARIES
Split AC, (2 Ton capacity) for newly built SPR.
Lighting system for SPR Room
Lighting system for Control Room as per TS
415 V ACDB AS PER TS, SUITABLE FOR MALDA SWITCHYARD
110 V DCDB AS PER TS SUITABLE FOR MALDA SS
110 V DCDB PANEL EXTENSION FOR MALDA SS
48 V, DCDB AS PER TS SUITABLE FOR MALDA SS
Supply of 48V, 80A/80A Float Cum Boost Battery Charger
Supply of 48V, 800 Ah Battery
Supply of Co-axial cable due to shifting of panels
Fire Detection and Alaram System for SPR
Fire Detection and Alaram System for Control Room Building
Indoor AC Lighting Panel Type ACP1 as per TS
Indoor DC Lighting Panel Type DCP as per TS
Indoor AC Sub Distribution Box Type Sub-DB as per TS
Receptacles Type RO as per TS
SUBSTATION AUXILIARIES
Interfacing of system under present scope with the existing SAS and upgradataion of hardware and software, augmentation of exiting SAS including NTAMC integration
All Prices are in INR
Description
400KV Equipment
Erection of 3000A, 50kA, Pantograph isolator ( 3phase) with one earth switch (Tandem arrangement)
Erection of 3000A, 50kA, Pantograph isolator (3 phase) without Earth switch (Tandem arrangement)
Erection of 3000A, 50kA DBR isolator (3 phase) without 2 Earth switch
Erection of standard pipe structure for Pantograph Isolator (3 phase) for 400 KV
Erection of standard structure for DBR Isolator (3 phase) for 400 KV
FOUNDATION BOLT 28 MM DIA
Erection portion peratining to earthing work related to 40 mm MS Rod main mat
Removal of existing old cables from removed Isolators/CT/CVT/CB to BMK & old CR for Both 400 KV & 220 KV Side:-
Removal of old control cable (5 C X 2.5 sq mm)
Removal of old control cable (7 C X 2.5 sq mm)
Removal of old control cable (10 C X 2.5 sq mm)
Removal of old control cable (14 C X 2.5 sq mm)
Removal of old control cable (19 C X 2.5 sq mm)
Removal of old control cable (27 C X 2.5 sq mm)
Removal of 1.1 KV Grade 3.5 C X 35 sq mm PVC power cable
Removal of 1.1 KV Grade 3.5 C X 70 sq mm PVC power cable
Removal of 1.1 KV Grade 3.5 C X 95 sq mm PVC power cable
Laying & termination of 5C x 2.5 Sq mm Control Cable
Laying & termination of 7C x 2.5 Sq mm Control Cable
Laying & termination of 10C x 2.5 Sq mm Control Cable
Laying & termination of 14C x 2.5 Sq mm Control Cable
Laying & termination of 19C x 2.5 Sq mm Control Cable
Laying & termination of 27C x 2.5 Sq mm Control Cable
Laying & Termination of 1.1 KV Grade, 3.5C X 35 Sq mm (PVC) Power Cable
Laying & Termination of 1.1 KV Grade, 3.5C X 70 Sq mm (PVC) Power Cable
Laying & Termination of 1.1 KV Grade, 3.5C X 95 Sq mm (PVC) Power Cable
Laying & Termination of 1.1 KV Grade, 3.5C X 185 Sq mm (PVC) Power Cable
Laying & Termination of 1.1 KV Grade, 4C X 6 Sq mm (PVC) Power Cable
Laying & Termination of 1.1 KV Grade, 1C X 185 Sq mm (XLPE) Power Cable
Dismantling of existing Centralised Bus Bar with panel and handing over to Malda O&m Store with packing
Fire Detection and Alaram System for SPR
220KV Equipment
1600A,40kA DBR isolator (3 phase) with 01 earth switch
1600A, 40kA HCB isolator (3 phase) without earth switch (Tandem arrangement)
1600A, 50kA DBR isolator (3 phase) with 2 earth switch
1600A, 40kA DBR isolator (3 phase) without earth switch (Tandem arrangement)
BPI suitable for 220 KV.
Complete Substation Automation System for the following 400kV bays as per Technical Specification and Scope of work:
400kV Line bays
400kV Transformer bays
400kV TBC bays
400kV BC bays
400kV non-switchable line reactor bay
Sub - Total 2.1.1
220kV Line bays
220kV Transformer bays
220kV TBC bays
220kV BC bays
Complete substation automation system for controlling and monitoring of auxiliary system including BCU as per TS
Sub - Total 2.1.2
400kV CB relay panels with A/R (with automation)
400kV CB relay panels without A/R (with automation) as per TS.
400kV Line Protection Panel (with automation)
400kV Transformer protection panel (HV & MV sides) with automation
400kV reactor protection panel with automation
Low Impedance type distributed Bus bar protection (Duplicated) for complete 400 KV Switchyard with automation
Time synchronisation equipment
33 KV Protection panel for Transformer (with automation)
220kV Circuit Breaker Relay Panel with auto reclose (with automation)
220kV Circuit Breaker Relay Panel without auto reclose (with automation)
220kV line protection panel (with automation)
220kV transformer protection panel (for both HV & MV side)-(with automation)
Low Impedance type distributed Bus bar protection for complete 220 KV Switchyard, single busbar protection with automation
Sub - Total 3.2
Split AC, (2 Ton capacity) for newly built SPR.
Lighting system for SPR Room
Lighting system for Control Room.
415 V ACDB AS PER TS, SUITABLE FOR MALDA SWITCHYARD
110 V DCDB AS PER TS SUITABLE FOR MALDA SS
110 V DCDB PANEL EXTENSION FOR MALDA SS
48 V, DCDB AS PER TS SUITABLE FOR MALDA SS
Erection of Co-axial cable due to shifting of panels
Sub Total
Shifting Of ACDB/DCDB etc to New CRB
Sub - Total: 5.1
Interfacing of system under present scope with the existing SAS and upgradataion of hardware and software, augmentation of exiting SAS including NTAMC integration
All Prices are in INR
DSR 2021 item no.
First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.
Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.(The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.)
Market Rate
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete
LOA rate
LOA rate
LOA rate
LOA rate
LOA rate
LOA rate
Rate Analysis
LOA rate
LOA rate
LOA rate
LOA rate
LOA rate
LOA rate
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :
LOA rate
LOA rate
LOA rate
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
Providing and fixing on wall face unplasticised - Rigid UPVC/PVC SWR ( sewage, waste and rainwater) pipes confirming to IS 13592 TYPE A including jointing with seal ring confirming to IS 5382 leaving 10mm gap for thermal expansion
150 mm diameter
110 mm diameter
75 mm diameter
Providing and fixing bend of required degree with access door
150 dia uPVC
110 dia uPVC
75 dia uPVC
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Shoe (Plain)
Rate Analysis
Non DSR
Analysed from 11.2
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
CR BUILDING DRAWING.PDF
pdf • 7.35 MB
8-Attachment and Bid Forms Vol.III..xls
xls • 2.47 MB
Malda Tender BOQ_final.xls
xls • 0.13 MB
SFQP_CIVIL_REV-05.pdf
pdf • 1.75 MB
TS_CIVIL_REV-11A.pdf
pdf • 1.99 MB
TS_SWITCHYARD.pdf
pdf • 3.81 MB
CR BUILDING DRAWING_1.pdf
pdf • 4.23 MB
CR BUILDING DRAWING_2.pdf
pdf • 7.35 MB
Malda_SLD.pdf
pdf • 0.34 MB
SAS_CRP_FAT.pdf
pdf • 0.54 MB
7 SCOPE OF WORK.docx
docx • 0.06 MB
TS_AIR_CONDITIONING.pdf
pdf • 0.04 MB
TS_BATTERY_CHARGER.pdf
pdf • 1.05 MB
TS_FIRE_PROTECTION.pdf
pdf • 1.97 MB
TS_GTR.pdf
pdf • 1.09 MB
TS_LIGHTING_SYSTEM.pdf
pdf • 0.91 MB
TS_LT_SWITCHGEAR.pdf
pdf • 0.47 MB
TS_POWER_CABLE.pdf
pdf • 0.26 MB
TS_REQUIREMENT_SEC.pdf
pdf • 0.61 MB
TS_SECTION_CRP.pdf
pdf • 0.37 MB
TS_SECTION_SAS.pdf
pdf • 0.98 MB
TS_STRUCTURE.pdf
pdf • 0.10 MB
TS_SWITCHGEAR.pdf
pdf • 0.11 MB
CABLE TRENCH.pdf
pdf • 0.63 MB
Foundation 400kV.pdf
pdf • 0.10 MB
Layout.jpg
jpg • 4.81 MB
Panel Room (6M).pdf
pdf • 0.60 MB
Panel Room (9M).pdf
pdf • 0.63 MB
SPR_9M.pdf
pdf • 0.58 MB
SPR_CABLE_TRENCH.pdf
pdf • 0.57 MB
~$ IFB VOL I.doc
doc • 0.00 MB
~$ BDS Vol I.doc
doc • 0.00 MB
~$ BDS Vol.I.doc
doc • 0.00 MB
~$ Forms and Procedures Vol I.doc
doc • 0.00 MB
~$SCC Vol.I .doc
doc • 0.00 MB
01 IFB VOL I.doc
doc • 0.33 MB
02 Section-II ITB SSTE SI Rev 5.pdf
pdf • 0.63 MB
03 BDS Vol I_Malda.doc
doc • 0.34 MB
03A Annexure-A(BDS).pdf
pdf • 0.53 MB
03B Annexure-B(BDS).docx
docx • 0.02 MB
03C Annexure-C(BDS).docx
docx • 0.03 MB
04 Section-IV GCC SI Rev 3.pdf
pdf • 1.93 MB
05 SCC Vol I .doc
doc • 0.08 MB
05A-Appendix-3 Insurance (SCC).pdf
pdf • 3.50 MB
06 Forms and Procedures Vol I.doc
doc • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .