Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹92.4 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹1.0 Cr+₹11.0 L (11.9%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹1.1 Cr+₹17.8 L (19.2%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | CIVICTRA ENGINEERING AND CONSTRUCTIONS L1 | A to Z Service Solution L2 | M/s MIR ELECTRICAL L3 |
|---|---|---|---|---|---|---|
| 1.00(A)Design, manufacture, supply, packing & forwarding, transportation, delivery at site of equipments and materials. | ||||||
| 2.00Structures | ||||||
| 3.00 | Fabrication, galvanisation, supply including packing and forwarding, transportation charges of 132 kV & 33 kV structures (each type) | 13 | MT | 1,38,000 ₹17,94,000 | 1,50,155 ₹19,52,015 | 1,15,000 ₹14,95,000 Lowest |
| 4.00 | Galvanised Nuts & Bolts of sizes | 0.75 | MT | 1,38,000 ₹1,03,500 | 1,79,550 ₹1,34,662.5 | 1,25,000 ₹93,750 Lowest |
| 5.00Main Equiupments | ||||||
| 6.00Circuit Breakers | ||||||
| 7.00 | 3 pole,VCB, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (36KV, 1250 Amps of 3 phase, 50 c/s and 25KA for 1 second). | 1 | No | 5,43,000 ₹5,43,000 | 4,94,013 ₹4,94,013 | 4,50,000 ₹4,50,000 Lowest |
| 8.00Isolators | ||||||
| 9.00 | 36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades | 3 | No | 2,21,000 ₹6,63,000 | 1,49,625 ₹4,48,875 Lowest | 1,95,000 ₹5,85,000 |
| 10.00 | 36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Blades | 3 | No | 2,31,000 ₹6,93,000 | 1,59,600 ₹4,78,800 Lowest | 2,12,000 ₹6,36,000 |
Tender Value
₹1.0 Cr
Closing Date
4 Feb 2021, 4:00 pmClosed
Executive Engineer TLMD II Pampore
Executive Engineer TLMD II Pampore
Construction of 33 kV Line bay and upgradation of Conductor of 132 kV Mirbazar I and II Line bays and civil works at Grid Station wanpoh
2020_PDD_112287_1
TLMD-II/29 of 2020
Open Tender
Electrical Works
Item Rate
120 days
Grid Station Wanpoh
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,000
Yes
Executive Engineer TLMD II Pampore
Exempted
22 Feb 2021
24 Dec 2020
5 Feb 2021
24 Dec 2020
4 Feb 2021
24 Dec 2020
Amount
(A)Design, manufacture, supply, packing & forwarding, transportation, delivery at site of equipments and materials.
Structures
Fabrication, galvanisation, supply including packing and forwarding, transportation charges of 132 kV & 33 kV structures (each type)
Galvanised Nuts & Bolts of sizes
Main Equiupments
Circuit Breakers
3 pole,VCB, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (36KV, 1250 Amps of 3 phase, 50 c/s and 25KA for 1 second).
Isolators
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Blades
Surge Arrestors
Single Phase 36KV 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries
Control and Relay Panels
33KV Control and Relay Panel for Line/Feeder completely wired including Substation automation supporting IEDs/numerical relays
Current Transformers
Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 25KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA
Post Insulators
33KV Post Insulators Solid Core Type, Power Frequency Withstand Voltage 95KVP Dry lightning impulse withstand voltage ± 170 (KVP)
Power and Control cables including termination of the cables
1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete as per specification.
2 Core, 2.5 sq mm
5 Core, 2.5 sq mm
8 Core, 2.5 sq mm
10 Core, 2.5 sq mm
16 Core, 2.5 sq mm
2 Core, 6 sq mm
4 Core, 6 sq mm
Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self-supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns.
Cable Glands, ferrules & Lugs for all above cables etc.
ANCILLARY ITEMS
500mm2 ACSR Moose Conductor (a)Aluminium =54/3.53 mm (b) Steel= 7/3.53 mm overall diameter =31.77mm Approx. Wt. =1998 kg/km ultimate strength = 159.60 KN
400mm2 ACSR Zebra Conductor
Single Tension Fittings For Twin 500 mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
Single Tension Fittings For Single 500mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
Single Suspension Fittings For Single 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
Single Suspension Fittings For Twin 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
T Clamps Twin 500mm2 / Twin 500mm2 , made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
T Clamps single 500mm2 / single 500mm2 , made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
PI clamps suitable for twin 500mm sq ACSR shall comply in all respects with IS:5561-1970 (latest edition)
PG clamps suitable for single 500mm sq ACSR
Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected.
Disc Insulators 70 KN,Ball & Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.
Spacers For Twin 500mm2 must be one-piece construction of aluminum alloy of an approved type without any projection, cuts, abrasions etc. or chattering parts and shall conform to IS:10162
Earth Wire 7/3.15mm
Earthwire Tension Clamps comprise of compression type tension clamp with two ‘D’ shackles, jumper terminals, nuts & bolts and washers etc.slip strength shall not be less than 95% of the ultimate strength of the ground wire. Conductivity shall not be less than corresponding length of GSS ground wire
Single Tension Fittings For Single 400mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
Single Suspension Fittings For Single 400mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected.
T Clamps 400mm2 /400mm2, made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
P G Clamps made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition) for 400 sq mm ACSR
Pad clamps suitable for 400 mm2 conductor
CABLE TRAYS/CABLE RACKS/ACCESSORIES
Cable Trays of size 400mm x 3000mm made of M.S angles 40x40x6mm,40x6 Flat.
Cable Trays of size 300mm x 2500mm made of M.S angles 40x40x6mm,40x6 Flat.
Lugs, Ferrules, Welding Material, Cotton Waste etc (132KV,33KV side)
Mandatory spares
Set of spares foras per schedule of spares given in SBD.
(B) HANDLING, STORAGE, PRESERVATION, ERECTION (EXCEPT CIVIL WORKS), DEHYDRATION, TESTING & COMMISSIONING OF EQUIPMENTs AND MATERIAL
Structures
Fabrication, galvanisation, supply including packing and forwarding, transportation charges of 132 kV & 33 kV structures (each type)
Galvanised Nuts & Bolts of sizes
Main Equiupments
Circuit Breakers
3 pole,VCB, out door Circuit Breaker , including all accessories, auxiliaries and marshalling boxes/Kiosks, (36KV, 1250 Amps of 3 phase, 50 c/s and 25KA for 1 second).
Isolators
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators without Earthing Blades
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Blades
Surge Arrestors
Single Phase 36KV 50 c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor including Surge counters/monitors, insulating base all associated accessories, auxiliaries
Control and Relay Panels
33KV Control and Relay Panel for Line/Feeder completely wired including Substation automation supporting IEDs/numerical relays
Current Transformers
Single phase, 50 c/s 36KV Current Transformers (1200-600-300 /1-1-1 A or as per site specifications) , 25KA for one second, rated dynamic current 25KA(peak), Class A insulation, Burden 20 VA
Post Insulators
33KV Post Insulators Solid Core Type, Power Frequency Withstand Voltage 95KVP Dry lightning impulse withstand voltage ± 170 (KVP)
Power and Control cables including termination of the cables
1100 V, PVC insulated, PVC sheathed, FRLS, galvanised steel wire/ strip armoured stranded copper conductor control cable complete as per specification.
2 Core, 2.5 sq mm
5 Core, 2.5 sq mm
8 Core, 2.5 sq mm
10 Core, 2.5 sq mm
16 Core, 2.5 sq mm
2 Core, 6 sq mm
4 Core, 6 sq mm
Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, self-supporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns.
Cable Glands, ferrules & Lugs for all above cables etc.
ANCILLARY ITEMS
500mm2 ACSR Moose Conductor (a)Aluminium =54/3.53 mm (b) Steel= 7/3.53 mm overall diameter =31.77mm Approx. Wt. =1998 kg/km ultimate strength = 159.60 KN
400mm2 ACSR Zebra Conductor
Single Tension Fittings For Twin 500 mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
Single Tension Fittings For Single 500mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
Single Suspension Fittings For Single 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
Single Suspension Fittings For Twin 500mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
T Clamps Twin 500mm2 / Twin 500mm2 , made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
T Clamps single 500mm2 / single 500mm2 , made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
PI clamps suitable for twin 500mm sq ACSR shall comply in all respects with IS:5561-1970 (latest edition)
PG clamps suitable for single 500mm sq ACSR
Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected.
Disc Insulators 70 KN,Ball & Socket type, 145mm height and 255mm dia. Creepage total 430 mm and 260 mm protected.
Spacers For Twin 500mm2 must be one-piece construction of aluminum alloy of an approved type without any projection, cuts, abrasions etc. or chattering parts and shall conform to IS:10162
Earth Wire 7/3.15mm
Earthwire Tension Clamps comprise of compression type tension clamp with two ‘D’ shackles, jumper terminals, nuts & bolts and washers etc.slip strength shall not be less than 95% of the ultimate strength of the ground wire. Conductivity shall not be less than corresponding length of GSS ground wire
Single Tension Fittings For Single 400mm2 ACSR shall have minimum failing load of 100% ultimate strength of Bundle conductors with compressive type Tension clamps having slipping strength 95% of ultimate Strength of conductors. The ball and socket designation must be 20mm. Minimum Ultimate strength (Tensile strength) shall be 70 KN.
Single Suspension Fittings For Single 400mm2 conductor shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 20mm.
Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected.
T Clamps 400mm2 /400mm2, made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition)
P G Clamps made of Alluminium Alloy and shall comply in all respects with IS:5561-1970 (latest edition) for 400 sq mm ACSR
Pad clamps suitable for 400 mm2 conductor
CABLE TRAYS/CABLE RACKS/ACCESSORIES
Cable Trays of size 400mm x 3000mm made of M.S angles 40x40x6mm,40x6 Flat.
Cable Trays of size 300mm x 2500mm made of M.S angles 40x40x6mm,40x6 Flat.
Lugs, Ferrules, Welding Material, Cotton Waste etc (132KV,33KV side)
(D) Civil Works including design, supply, excution and prepration of drawings
Foundations for gantry and foundation structures
Earth work in excavation by mechanical means (Hydraulic excavator) over areas ( exceedind 30 cm in depth 1.5 mtr in width as well as 10 sq.m on plan ) including disposal of excavated earth, lead upto 50 m. & , lift upto 1.50 m disposad earth to be levelled and neatly dressed. a) All kinds of soil
Providing and laying of lean pad 1:4:8 with 40mm crushed stone aggregate
Stub setting for columns foundations including template setting excluding cost of material
Fixing of foundation bolts including alignment
Filling available excavated earth(excluding rock) in trenchs,plinth,sides of foundation etc. layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering lead upto 15 mtr and ift upto 1.5 mtr.
Reinforcement for R.C.C. work including providing, straightning, cutting,bending, placing in position and binding all complete bars (TMT)
Providing & laying in position R.C.C (excluding the cost of centring and shuttering and reinforcement in 1:2:4(1 cement:2 coarse sand:4 graded stone aggregate 20 mm nominal size))
Mechanical carriage of materials from different sources upto dumpying site on an average lead of 20 kms:-
(a) Reinforcement.
(b) Foundation bolts
(c) Sand
(d) Bajri (40mm/20 mm)
(e) Cement
Mannual Carriage of materials from dumpying site upto actual site of work (average lead 100 mtr.) :-
(a) Reinforcement.
(b) Foundation bolts
(C) Sand
(d) Bajri (40 mm/20 mm)
(e) Cement
Clearance of site foundation by removal of grass vegetation and demarcation and alignment,pit marking of complete coulomn foundation.
Mech carriage ofdisposable earth av lead 20 km
Dismentalling of existing R R Masonary wall at Grid station Wanpoh for providing proper space for new line bay
Dismentaling of existing R R Massionery wall 1x90x0.9x1.6 m
Carriage of dismentalled material from dismenatalled site to loading site within 200 mtrs, By manual labours
Loading & unloading of stones( at Grid station) for disposal of same
Carriage of materials from Grid station to the damping site by Mechanical Transport within 5 kms
Construction of outer R C C wall at Grid station Wanpoh for sepeation of staff Quaters
Earth work excavation in bulk in the foundation ,not exceeding 10 sq mtr & 1.5 mt in width with lift of 1.5 mts & disposal of same within 25 mtrs , 20x1mx0.5 m
Disposal of excavated earth out side side grid station in the mechanical transport avg lead of 1 km
Providing & laying of stone soilings, 20mx1x0.2
Providing & laying ofcement (1:4:8 ) 20 m X 1X0.2m
Providing & laying, framing & fixing of reinforcement
Providing & laying of RCC IN 1:2:4 ratio 20mx(1+0.6)/2 X1.2m
form work of the RCC above ground level 2x20mx1m
carriage of line materaials from different sources to the working site by Mech Transport avg lea 20 km
cement
bajari
soiling
Cement
Construction of Control Desk
Providing and fixing of 12mm thick ply board for control desk
Providing and fixing of 6mm thick ply board for control desk
Providing and fixing flat pressed 3 layer particle board 18 mm thick medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames,backing or studding to be paid separately):
Providing Oxidised M. S. hinges finished with nickel plating 50 mm
Providing and fixing 1mm decorative high pressure laminated sheet of plain/wood grain in gloss/matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 TypeS. including cost of adhesive of approved quality
Providing and fixing of drawer channels
Providing and fixing aluminium tower bolts, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 150x10 mm
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete Double strip (horizontal type)
Providing & Fixing chromium plated brass handles with necessary screws etc completes
Providing and fixing special quality bright finished brass cupboard of ward robe locks with four levers including necessary screws etc. complete (40 mm)
Dismantalling of existing wooden control desk
Construction of Cable Trenches
Earthwork in excavation by manual means in trenchs for foundations , drains , pipes , cables etc ( exceeding 1.5 m in width ) and for shafts , wells ,cesspits and the like not exceeding 10 sqm on plan , depth upto 1m from cutting edge ,disposed earth to be levelled and neatly dressed in . All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering. All work upto plinth level in 1:4:8 (1 cement:4 coarse sand:8 graded stone aggregate 40mm nominal size)
Providing & Laying of reinforced cement concrete in M-15 grade incl. curing complete but excl. centring & shuttering (Bed and walls)
Reinforcement for RCC works including straightening, cutting , bending, placing in position and binding all complete. Thermo-mechanically treated bars (12 mm bars)
Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Carriage of materials by mechanical transport
Sand with a lead of avg 30km
Crusher Aggregate with a lead of avg 10 km
Cement
Concreting of 33 kV Lien bay including laying of Gravel
Surface dressing of ground, removal of inequalities, de-vgetation, excavation of earth
Supply and laying of stone soling 100 mm thick
Providing and laying of cement concrete 1:3:6 mix 100 mm thick
Providing and spreading of 40 mm size metal on the concreted portion
Mechanical carriage of material (Avg Distance 20 km)
Stone Aggregate
Cement
Manual carriage of material
Stone Aggregate
Cement
A to Z Service Solution
M/s MIR ELECTRICAL
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.53 MB
SBD2NavG.pdf
Tender Documents • 4.63 MB
MandSNavG.pdf
Tender Documents • 0.35 MB
BOQ_214704.xls
BOQ • 0.38 MB
SBD1NavG.pdf
Tender Documents • 1.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .