Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 CrAccepted-AOC | ₹9.4 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹14.1 Cr+₹4.7 Cr (50.6%)Rejected-Finance C O GUPTA EMPORIUM AR BAZAR HAPPY VALLEY SHILLONG 793 004 | EAST KHASI HILLS | MEGHALAYA | 793004 | ₹14.1 Cr+₹4.7 Cr (50.6%) | L2 | Rejected-Finance Not Being lowest |
| 3 | L3₹17.3 Cr+₹7.9 Cr (83.8%)Rejected-Finance CITY TOWER BUILDING ROOM NO 306 CIRCULAR ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | NAGALAND | 797112 | ₹17.3 Cr+₹7.9 Cr (83.8%) | L3 | Rejected-Finance not Being lowest |
Tender Value
₹10.4 Cr
EMD Value
₹8.5 L
Closing Date
17 Dec 2022, 6:00 pmClosed
CE SHILLONG ZONE
HQ CE SHILLONG ZONE, SPREAD EAGLE FALLS, SHILLONG, MEGHALAYA
PROVISION OF MARRIED OFFICERS ACCOMMODATION AT UMROI MIL STN UNDER GE UMROI
2022_MES_559481_1
CESZ/UMR/ OF 2022-23
Open Tender
Civil Works
Lump-sum
730 days
UMROI
All as per NIT
2 documents required · 2 mandatory
₹3,000
GE UMROI
₹8.5 L
Yes
29 Dec 2022
22 Oct 2022
19 Dec 2022
22 Oct 2022
17 Dec 2022
6 Dec 2022
Amount
NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Lumpsum price workedout by the tenderer for BUILDING & STRUCTURE WORKS as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the bidder/ tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule 'A' Part-II.
Lumpsum price worked out by the bidder/ tenderer for INTERNAL & HOT WATER SUPPLY as listed in Schedule 'A' Part-III.
Lumpsum price worked out by the bidder/ tenderer for INTERNAL ELECTRIFICATION as listed in Schedule 'A' Part-IV.
Lumpsum price worked out by the bidder/ tenderer for ROAD, PATH & CULVERT as listed in Schedule 'A' Part-V.
Lumpsum price work EXTERNAL WATER SUPPLY as listed in Schedule 'A' Part-VI.
Lumpsum price worked out by the bidder/ tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule 'A' Part-VII.
Lumpsum price work SEWAGE DISPOSAL as listed in Schedule 'A' Part-VIII.
Lumpsum price work AREA DRAINAGE as listed in Schedule 'A' Part-IX.
Lumpsum price work RETAINING WALL as listed in Schedule 'A' Part-X.
Sch 'A' Sec-XI (Miscellaneous Items) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Supplying and laying of 32 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches including special fittings like CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor) complete all as specified and directed.
Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches including special fittings like CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor) complete all as specified and directed.
Supplying and laying of 40 mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors/trenches including special fittings like CPVC Brass fittings (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor) complete all as specified and directed.
Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including modular metal flush box and white cover plate with frame of suitable module complete for one light/fan/bell/exhaust point controlled by one way switch.
Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including modular metal flush box and white cover plate with frame of suitable module complete for one socket outlet point 6 Amp on same board.
Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including modular metal flush box and white cover plate with frame of suitable module complete for one socket outlet point 6 Amp on independent board.
Point wiring with 1.5 Sq. mm (nominal cross sectional area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including modular metal flush box and white cover plate with frame of suitable module complete for light point controlled by two 2-way switches.
Point wiring with 2.5 Sq. mm (nominal area) PVC insulated and un-sheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC rigid concealed conduit and conduit accessories alongwith continuous earth wire 2.5 Sq mm PVC insulated and un-sheathed single core FRLSH cable 1100 volts grade with multi-stranded copper conductor and connected to common earth dolly, with and including modular metal flush box and white cover plate with frame of suitable module complete for one16 Amps socket outlet on independent board.
Sub main wiring with four runs of single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable of size 4 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size PVC concealed conduit and accessories (IS-694 marked in PVC conduit) and fittings and one run of 4 Sq mm single core FRLSH multistranded copper conductor cable as earth continuity conductor. NOTES :- (a) Four runs of copper conductor, one run of earth wire and one run of conduit shall be measured as one run length.
Sub main wiring with two runs of single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable of size 4 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size PVC concealed conduit and accessories (IS-694 marked in PVC conduit) and fittings and one run of 4 Sq mm single core FRLSH multistranded copper conductor cable as earth continuity conductor. NOTES :- (a) Two runs of copper conductor, one run of earth wire and one run of conduit shall be measured as one run length.
Supply & fix Sheet metal enclosure, epoxy powder coated Distribution Board vertical TPN 415 Volts 4 Way, 12 module double door type with suitable rated common bus bar for fixing incomer MCCB and outgoing MCB.
Supply and fixing MCCB 4 pole 415Volt, 63 Amps with adjustable thermal and magnetic release 25 KA complete all as specified and directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke dust and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.
Sub main wiring with two runs of single core FRLSH PVC insulated and unsheathed multistranded, copper conductor cable of size 2.5 Sq mm (nominal area), 1100 volts grade drawn through and including adequate size PVC concealed conduit and accessories (IS-694 marked in PVC conduit) and fittings and one run of 2.5 Sq mm single core FRLSH multistranded copper conductor cable as earth continuity conductor. NOTES :- (a) Two runs of copper conductor, one run of earth wire and one run of conduit shall be measured as one run length.
Supply and fix electric water heater, storage type ABS body with porcelain enamel glass lined inner tank of capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, with grouting bolts and nuts, including suitable capacity flexible cable 3 core with 3-pin plug of 16 Amp capacity maximum 2mtr length, PVC connection pipe of size 15mm dia and 450mm length for hot Cold water complete all as specified and as directed.
Material, labour and applying road marking paint(2.5mm thick), retro-reflective type of specified shade / colour using hot thermoplastic material by automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cleaning the road surface and remove all dirt, seals, oil, grease and foreign material etc. complete all as per manufacturer's instructions and as per direction. Complete all as specified and directed.
Supply, laying and jointing of ductile iron pipes of 100mm bore with spigot and socket ends conforming to IS 8329 : 2000, suitable for push on rubber joint centrifugally cast, class (K-7), inner side cement lining and outer side black bitumen coating and any length, laid in trenches or fixed in floors or on walls including push on rubber (EPDM) ring with ISI marked complete all as specified and directed. Note: Ductile iron fitting such as Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs of suitable size shall be measured and paid separately under relevant item.
Supply & Fix 150mm bore sluice valve (operation-cap) both side flanged, ISI marked (IS No 14846-2000 class PN-1.6) having cast iron body, cast iron hand wheel, non rising type with brass spindle, cheek nuts and sliding gate and body width including testing against leakage and supply of nuts & bolts complete all as specified and as directed.
Supply & Fix 100mm bore sluice valve (operation-cap) both side flanged, ISI marked (IS No 14846-2000 class PN-1.6) having cast iron body, cast iron hand wheel, non rising type with brass spindle, cheek nuts and sliding gate and body width including testing against leakage and supply of nuts & bolts complete all as specified and as directed.
M&L for construction of brick masonry valve pit of size 1200 X 1200 X 1200 mm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded aggregate) as in foundation, and 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made of 3mm thick MS sheet/plate, welded including provision of hinges, handle and locking arrangement including 40 X 40 X 6mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, including two coats of anti-corrosive paint over a coat of red oxide zinc Chrome primer and necessary earth work in soft/loose soil complete all as specified & directed.
M&L for construction of brick masonry valve pit of size 900 X 900 X 900 mm (internal dimension) one brick thick wall in CM 1:4 on 100mm thick PCC 1:4:8 type D-2 (40mm graded aggregate) as in foundation, and 15mm thick rendering in cement mortar (1:4) internally, externally up to 15cm below GL, providing valve pit cover made of 3mm thick MS sheet/plate, welded including provision of hinges, handle and locking arrangement including 40 X 40 X 6mm angle iron frame fixed on top of valve pit by means of hold fast 150mm long, embedded in PCC block 1:2:4 type B-1 (20mm graded aggregate) of size 230 X 200 X 100mm, including two coats of anti-corrosive paint over a coat of red oxide zinc Chrome primer and necessary earth work in soft/loose soil complete all as specified & directed.
Supply, install, testing and commissioning of distribution Tranformer out door, step down,copper wound having primary side for HT 11KV & secondary for 3 phase 433 Volts, 4 wire 50 Hz capacity of 160 KVA and Energy efficient Level -3 as per IS 1180 of 2014 Part-I placed on and icluding necessary plinth/PCC foundation of height 2mtr (M-10) using 40mm graded stone aggregate with the following specification :- (i) No load voltage ratio-11/0.433 KV. (ii) Nos of phase-three. (iii) Type of cooling- ONAN. (iv) Frequency 50 Hz. (v) Vector group-DYN 1. (vi) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing. (vii) First fill of oil, oil level gauge indicating oil level minmum and maximum. (viii) Liftinglugs.
Sr Item No. 11.22(Contd/..) (ix) Rating and terminal marking plates. (x) dehydrating breathing divice which would not permit ingress of rain water and insects. (xi) Drain-cum-sampling valve (3/4" nominal size thread) preferably steel with plug. (xii) Thermometer pocket. (xiii) Oil filling hole( 1-1/4" Nominal size thread) with cover. (xiv) Connection-Delta/Star. (xv) Temperature rise in oil-45 deg Centigrade. (xvi) Temperature rise in windings- 55 deg Centigrade. (xvii) Material winding-Copper wound. (xviii) High voltage/low voltage-Bushing with box (xix) Service-Outdoor type. (xx) Neutral- Internally connected with earthing lead and bush. (xxi) Off load tap changing (+ or - 7.5% in step of + or - 2.5% or as per IS relevant) (xxii) Transformer losses as per Energy conservation builiding code(2008) as specified. (xxiii) Fitting Accessories: as per clause No 149.14.1.2 of SSR Part-I
Supply, install test and commissioning of automatic power factor (APFC) panel outdoor type for 30 KVAR 3 Phase, 440 volts 50 HZ with multistage correction (MPP-H capacitor) capacitors operate in 7 steps configration will be (4 x 5 KVAr & 3 x 10 KVAr) Preiwired with suitable size copper conductor cable all suitable for fairly balance load, factory made, front & back openable, CPRI approved fabricated out of 3.15 mm thick CRCA (Cold Rolled Closed Annealed Cell) sheet compartmentalized design including mild steel channel frame of ISMC 50 at the base of panel only for grouting purpose (fabrication shall be done in transpotable sections) and grouted with PCC using 20 mm graded stone aggregate, duly epoxy powder coated. Panel board/box shall be provided with danger notice plate with skull & bone sign, PVC gasket and sealed, making all incoming and out going electrical cable connections with new lugs, glands to be provided at cable entries, entire enclosure shall have a common copper earth bar of size 25mm x 5 mm at the rear with 2 nos earth studs, solid connection from main bus bar to swich gears with required size of al. bus bars and control wiring with minimum 2.5 sq. mm PVC insulated copper conductor single core , cable alleys, cable gland plates in two half etc complete as required and all as specified and as directed. Each panel shall be comprising of following accessories:- (APFC Panel) (a) 100 Amps 16 KA MCCB 4 Pole 415 Volt - 1 Nos (Incomer) (b) CTs shall be provide for mesuring the capacitor corrent at incoming side of the panel
Material & Labour for Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion complete all as per specified and as directed.
Material & Labour for Earthing with Copper Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Copper Strip of size 20 x 3.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion complete all as per specified and as directed.
Material and labour for expulsion fuse assembly single pole vertically mounted on MS channel 11000 volts grade above 25A & upto 50 Amps capacity including making connections with HT cables/GOD with provision of jumper suitable crimped/fixed with appropriate size of lugs/connectors all as specified and as directed.
Material and labour for Lightening arrestor single pole zinc oxide (gap less) surge type heavy duty complete with all fittings, station class, discharge capacity 10 KA for 11 KV, 50 Hz conforming to IEC 99-4/1991 standard complete all as specified.
Supply & Fix nature switch in enclosure made out of UV stabilized, FR grade special moulding compound, rust proof, electric shock proof, vermine proof outdoor pole mountable with mounting bracket made out of FI and nut, bolts, washers including cable glands, openable door with lock comprising with power contactor single phase rating, 25 amps single pole-01 nos, MCB SP 25 Amps-03 Nos for max load 5kw, Ip 66 enclosure complete all as directed.
Supply and fixing for LED street light fitting 45 watt including pressure die cast aluminium housing, heat resistance glass, with IP 65 and testing on completion, complete all as specified and directed.
Supply and fix street light junction box of PVC of size 155 x 210 x 92mm consisting of 01 No MCB 6 Amps, 10 KA capacity (Single phasel) including aluminium strip bus bar for incoming and outgoing cable with necessary connection duly fixed on the pole with suitable size of MS clamp as approved and directed.
Material & Labour for stand alone solar street light 30 Watt LED energy efficient with minimum 120 Lm/watt alongwith suitable monocrystalline solar panel, lithium ferro phosphate battery, silicon encapsulated high efficiency MPPT charge controller and necessary protections against short circuit, battery protection etc. housed in suitable aluminium housing designed for better heat dissipation and to allow natural air for passive circulation within & into housing including mounting bracket and 6 mtr long MS pole duly painted with two coats of aluminium paint over a coat of primer. Including fixing arrangement with excavation, earth work, suitable anchor bolts and PCC as recommended by manufacturer.
Material & Labour for factory made indoor distribution board double door front openable type fabricated out of 2.0 mm thick MS sheet of size not less than 120 cm x 60 cm x 25 cm suitable for fixing one MCCB DB VTPN 4 way and 4 Nos electic energy meter including fixing of transparent glass on the positon infront of energy meters and including all fixing arrangements and glands for cable entry complete all as specified and directed. Note :- MCCB DB VTPN and energy meters will be measured and paid under separate items)
M&L for factory made indoor distribution board double door front openable type fabricated out of 2.0 mm thick MS sheet of size not less than 60 cm x 60 cm x 25 cm suitable for fixing one MCB DB TPN 4 way and 2/1 Nos electic energy meter including fixing of transparent glass on the positon infront of energy meters and including all fixing arrangements and glands for cable entry complete. Note :- MCB DB TPN and energy meters will be measured and paid under seperate items)
Supply & Fix or laying of 2 x 0.5 sq mm, 1.1 KV transparent FR PVC insulated, twin core copper conductor (flexible telephone cable) for connection of meter with parallel home display unit (Note :- PVC conduit and PVC junction box for connecting meter with parallel home display unit will be measured and paid separately)
Supply, install, testing and commissioning outdoor type LT panel of size 1.2 cm X 1.2 cm X 0.45 cm, CPRI approved factory made totally enclosed dust and vermin proof , double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door painted with powder coated paint and aluminium bus bar 400 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board including mounting over angle iron frame of size (50 x 50 x 6mm) 60 cm above the ground level including excavation & earthwork, returning filling in and removal of soil from site to a distance not exceeding 50m complete with the following items:- (Feeder Panel-2).
Sr Item No.11.35 (Contd) (a) MCCB, 4 Pole, 200A, 415 V, 35 kA.-Thermal/Magnetic adjustable type 01 No.(Incomming) (b) Phase indicator lamps (RYB) -set of 3 (c) Aluminium bus bar 4 strip of 400 Amps (d) Internal connection by aluminium strip from MCB/MCCB to busbar and busbar to MCCB/MCB etc (e) LED multifunctional meter with CT Ratio 200/5 (f) MCCB, 4 Pole, 63 A, 415 V, 25 kA, Thermal/Magnetic adjustable type - (Out Going - 03 Nos).(for three blocks having 4 qtrs) (g) MCCB, 4 Pole, 32 A, 415 V 30 kA, Thermal/Magnetic adjustable type - (Out Going -03 Nos) (for remaining three blocks)
Supply, install, testing and commissioning outdoor type LT panel of size (100cmx90cmx45cm) CPRI approved factory made totally enclosed dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, duly fabricated and having proper locking arrangement in both front and rear door painted with powder coated paint and aluminium bus bar 500 amps suitable for 500 volts, 50 Hz , 3 phase 4 wire system and comprising with and including following accesories and mounted on PCC platform all around the panel board including mounting over angle iron frame of size (50 x 50 x 6mm) 60 cm above the ground level including excavation & earthwork, returning filling in and removal of soil from site to a distance not exceeding 50m complete with the following items:- (Feeder Panel-1).
Sr Item No.11.36 (Contd) (a) MCCB, 4 Pole, 250A, 415 V, 25 kA. Thermal/Magnetic adjustable type- 01 No. (Main incomer) (b) MCCB, 4 Pole, 200A, 415 V, 25 kA.-Thermal adjustable type 01 No.(out going) for FP - II (c) MCCB, 4 Pole, 100A, 415 V, 25 kA.-Thermal adjustable type 01 No.(out going) for APFC panel (d) Phase indicator lamps (RYB) -set of 3 (e) LED multifunctional meter with CT Ratio 200/5 (f) Aluminium bus bar 4 strip of 500 Amps (g) Internal connection by aluminium strip from MCB/MCCB to busbar and busbar to MCCB/MCB etc (h) Space for mounting 01 no MCCB 4 pole upto 250 A
M & L for fixing of HDPE septic tank for 100 users design to carry sewage and sludge water including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m, plain cement concrete and Reinforced Cement Concrete M-30 for foundation as per manufactureres instruction as specified and directed.
M & L for soakage well of size 3.6 m dia and 4.5 m effective depth, including excavation in any type of soil earthwork, returning, filling in and removal of soil upto not exceeding 50m and as shown in TD drawing No. CESZ/2020/TD-45, sheet 1/2 & 2/2 complete all as specified and directed.
Supply & Fix Modular TV coaxial socket boxes, 1 module, ISI marked all as specified and directed.
Supply & Fix Ductile Iron Fittings for Spigot Socketed pipes of Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs suitable for 100mm bore pipe complete all as specified and as directed.
Supply, laying and testing of 160 mm nominal diameter High density polyethylene pipes (HDPE) of pressure rating PN4 as per IS : 14333 : 1996 for sewage line in any length, laid in trenches complete all as specified and as directed.
Supply, Installation, testing and commissioning of 03 phase, 4 wire single source direct connected BIS marked IS-16444 digital energy meter, 10-60 AMP 240V accuracy class-1.0 with GPRS/4G module for connectivity with HES and having LCD type display, calibration LED, optical communication port, push button for scroll and having features for load disconnection through internal latching relay complying as per UC1 and data download port for last 200 tamper event and load survey for last 45 days with all standard anti-temper features including sealing facility complete, using communication protocol DLMS and all as specified and directed
M/S UTTAM SAHA
M/S ALLIED CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ_626260.xls
BOQ Document • 0.60 MB
107546448.pdf
Tender Document • 6.41 MB
completetender.pdf
Tender Document • 7.24 MB
MainDRGTD.pdf
Tender Document • 17.23 MB
TDUMR.pdf
Tender Document • 17.84 MB
107546450.html
Tender Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .