Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹48.2 L+₹72,690 (1.53%)Rejected-Finance VILL NYUKMADUNG PO PS DIRANG DIST WEST KAMENG ARUNACHAL PRADESH 790101 | WEST KAMENG | ARUNACHAL PRADESH | 790101 | L2 | Rejected-Finance Bidder rejected due to other than L1 | |
| 3 | L3₹48.5 L+₹1.0 L (2.20%)Rejected-Finance | L3 | Rejected-Finance Bidder rejected due to other than L1 | |
| 4 | L4₹49.1 L+₹1.6 L (3.45%)Rejected-Finance | L4 | Rejected-Finance Bidder rejected due to other than L1 | |
| 5 | L5₹49.5 L+₹2.0 L (4.26%)Rejected-Finance | L5 | Rejected-Finance Bidder rejected due to other than L1 |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
10 Oct 2024, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Birendra Singh
GE 859 EWS, C/o 99 APO, PIN 913859
REPAIR MAINT AND REPLACEMENT OF WATER SUPPLY PIPE LINES, STORAGE TANKS AND STREET LIGHTS, POLES, SWITCHES AND CONNECTED ITEMS AT BAISAKHI OF AGE E/M UNDER GE 859 EWS
2024_MES_675304_1
8854/E8
Open Tender
Civil Works
Item Rate
180 days
Biasakhi
As per Tender Documents and NIT
6 documents required · 6 mandatory
₹0
₹91,000
Yes
26 Dec 2024
19 Sept 2024
11 Oct 2024
19 Sept 2024
10 Oct 2024
3 Oct 2024
Amount
Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles/fencing posts etc and getting out hard & densile soil complete all as specified and as directed by Engr-in-Charge.
Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning.
Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection , laid flat ie length of cable cover shall be laid across the cable, complete casted with PCC 1:2:4 Type B1 using 20mm graded crushed stone aggregateall as specified and directed
M&L for taking up or down PPR and connections of 110 mm dia including cleaning for refixing/replacing complete all as specified and directed.
Description all as per item No 6 of above but of size 75 mm dia all as specified & directed
Description all as per item No 6 of above but of size 63 mm dia all as specified & directed
Description all as per item No 6 of above but of size 50 mm dia all as specified & directed
Description all as per item No 6 of above but of size 40 mm dia all as specified & directed
Description all as per item No 6 of above but of size 25 mm dia all as specified & directed
Description all as per item No 6 of above but of size 20 mm dia all as specified & directed
Re-laying / re-fixing PPR pipe 110 mm bore with and including all fittings provided NEW ( ISI Marked) laid in trenches, under floor or fixed to walls / ceilings complete all as specified and as directed. Note :- Excavation & earth work for relaying will be measured & paid separately
Description all as per item No 13 of above but of size 75 mm dia all as specified & directed
Description all as per item No 13 of above but of size 63 mm dia all as specified & directed
Description all as per item No 13 of above but of size 50 mm dia all as specified & directed
Description all as per item No 13 of above but of size 40 mm dia all as specified & directed
Description all as per item No 13 of above but of size 25 mm dia all as specified & directed
Description all as per item No 13 of above but of size 20 mm dia all as specified & directed
S&F inreplacement of 3 layer 110 mm dia PP-R polypropylene random copolymer pipes SDR 7.4 (PN 16) UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. Make:- KPT pipes/SFMC/ Supreme
Description all as per item No 20 of above but of size 75 mm dia all as specified & directed Make:- KPT pipes/SFMC/ Supreme
Description all as per item No 20 of above but of size 63 mm dia all as specified & directed Make:- KPT pipes/SFMC/ Supreme
Description all as per item No 20 of above but of size 50 mm dia all as specified & directed Make:- KPT pipes/SFMC/ Supreme
Description all as per item No 20 of above but of size 40 mm dia all as specified & directed Make:- KPT pipes/SFMC/ Supreme
Description all as per item No 20 of above but of size 25 mm dia all as specified & directed Make:- KPT pipes/SFMC/ Supreme
Description all as per item No 20 of above but of size 20 mm dia all as specified & directed Make:- KPT pipes/SFMC/ Supreme
Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting existing 63/50 mm PPR pipe and making fusion joint etc.
Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting existing 40-20 mm PPR pipe and making fusion joint etc.
Supply and fix 63 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
Supply and fix 50 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
Supply and fix 40 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
Supply and fix 25 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
Supply and fix 20 mm bore outer dia PPR gave valve brass insert complete all as specified and directed.
S&F Gun metal gate valves of 80 mm bore, (class I), ISI marked with iron wheel head, screwed both ends for iron pipe, ISI marked, including dismantling U/S gate valves complete all as specified and directed . Make :- Zoloto /Jindal/Sant
Ball brass float valves, high pressure, with polythene float and flynut complete of PPR pipe of size 40 mm dia, screwed for iron pipe or brass ferrule and fixed including dismantling complete all as specified and as directed.
M&L for Construction of Valve pit of size 1050cm x 1050cm x 900cm (internal dimensions) with Brick masonry construction including all necessary excavation and earth work in hard/ dense soil,returning,filling,in disposal of surplus soil to a distance not exceeding 50 m and depositing where directed , PCC in foundation of the mix (1:4:8) Type D-2 (using 40 mm graded crushed stone aggregate), PCC Pocing in PCC(1:2:4), type B0 using 12.5m crushed graded aggregate, brick masonry work in cement mortar (1:4) rendering,15 mm thick in cement mortar (1:4) internally,finished even and fair and pointing in CM 1:3 flush pointing externally . Mild steel angle iron 50x50x6mm frame work ,MS sheet cover with 3.15mm thick with handle made of flat iron 30x5 mm thick and locking arrangment including providing pad lock ( Godrej/Link/Horisson ) 50 mm size Brass , and applying two coats of synthetic enamel paint of tint as approved over a coat of red oxide primer to all mild steel surfaces and providing two coats of black bituminous paint to all embedded portion of mild steel work etc. complete all as specified and directed by Engr-in-Charge.
M & L for cleaning of RCC/PS overhead reservoir of 10000-50000 gallon capacity, dewatering, taking out all deposits sludge / mud incl scrubbing/brushing to remove all funges growth inside the entire interior surface of the reservoir and washing thoroughly after clearing with bleaching powder and making ready for use incl writing of date of cleaning with existing colour and paint complete all as specified and directed by Engr-in-Charge. Note : Rate for dewatering UG sump/semi UG sump by using of diesel engine pump set required is deemed to be included in the quoted rate.
M&L labour for painting of PS tank of Capacity from 10000-50000 gallon taking out all sludges, removing and rubbing the outer surfece smoothly & applying two coats of synthetic enamel paint neatly , without any patches and writing capacity , date of cleaning after painting. Note:- cost of paint, necessary tools include in quoted rate.
Supply only Calcium Hypochlorite 65% to 70% chlorine content in packed with 45 Kg each drum (calcium based granular disinfectant for water treatment much more stable than chlorine gas and stronger than bleaching powder & sodium hypochlorite complete all as specified and directed. Make : Aquafit or equivalent as approved by NMPT committee of E-in-C's Branch. Note :-1.The contractor must submit the COC (Certificate of Compliance) in original from manufacturer by All India Authorised MES Distributor for each batch of product delivered indicating and including Chemical Analysis Report by All India Authorised MES Distributor. 2. The contractor must submit the COC (Certificate of Compliance) in original from manufacturer for each batch of product delivered including chemical analysis report. 3. The calcium hypochoride will be issued in sealed containers of capacity 30/45/50 KG, cost of same shall be included in quoted rate.
Supply only chlorine test kit with coloured ample complete with all testing fitments and 100 ml OT solution in rexine finish wooden box all as per sample complete all as specified.
Supply only OT solution in 200 ml bottle complete all as specified.
M&L for lagging to PPR pipe of 50 mm dia used in water supply or plumbing all round with,25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 with 0.01mm aluminium foil wrapping over minaral wool and securing foil with screws/ clamps all as specified & directed.
Description all as per item No 42 here in before but of size 40 mm dia
Description all as per item No 42 here in before but of size 25 mm dia
Description all as per item No 42 here in before but of size 20 mm dia
S&F PVC water storage tanks of 5000 ltrs capacity rotational moulded (3 layered cylindrical vertical with closed top) ISI marked hoisted and fixed in position complete all as specified and directed. Make:- Sintex or equivalent
S&F PVC water storage tanks of 2000 ltrs capacity rotational moulded (3 layered cylindrical vertical with closed top) ISI marked hoisted and fixed in position complete all as specified and directed. Make:- Sintex or equivalent
M&L for PCC 1:3:6 type C-1(20 mm graded aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete.
M & L for 15mm thick rendering on fair faces of brick,stone work/concrete surfaces of wall in CM (1:4), finished surface even and smooth without using extra cement complete all as specified and as directed.
M&L for PCC 1:3:6 Type C2 for foundation of platform, mass concrete with 40 mm gradede coarse agreegete complete all as specified and as directed.
M & L for road cutting incl necessary excavation 45 cm wide and 90 cm in depth as in trenches in any type of soils/rock for laying GI/PPR pipe after laying GI pipe trenches will be filling top with M&L PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm bolders 100 mm dia over filled and rammed earth to make good the disburbed surface etc
Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 16 sqmm 4 core including taking down of old unserviceable UG cable/service wires.Make :- Havells/KEI/Polycab
Description all as per item No 52 above but of size 16 Sqmm 2 core
S&F inreplacement of multistranded copper conductor PVC insulated sheathed of size 2.5 Sqmm 3 core for replacement from junction boc to security light all as specified & directed.
Supply and laying galvanised tube light grade ISI marked of size 40 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed.
S&F in replacement kiosk box for luminaires ,weather proof made out of HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole mounting type comprising of four pole copper connectors of 16 Amps capacitywith 6 Amp MCB single pole , of minimum size 300x200x105mm, fixed on pole with MS, clamps 30 x 5mm with necessary nuts, washer and incl applying two coats of synthetic enamel paint over a red oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box complete all as directed. The quoted rate also includes cost for material & repalcement of 4 sqmm multistranded twincore aluminium cable ISI marked from overhead conductor to junction box length as per required at site. Make- Sintex/Supreme/Hensal
S & F in replacement of GI brackets for fixing LED street light fitting fabricated out of GI tubing 40 mm dia, medium grade, 1.2 mtr long , bend to 120 degree shape by cutting, welding and well finishing including MS clamp of flat iron of size 32 x 4 mm -02 Nos complete for steel poles / PCC pole as per site requirement with nut, bolt & washers for fixing of GI bracket complete all as specified and directed.
M&L for painting of steel tubuler 9/8.5 mtr poles any type complete incl flat iron clamps, D clamps, Stay clamps, bracing, cross arm with two coat aluminium paint including prepration old painted surface initally & applying one coat of red oxide, applying two coat of aluminum paint over the red oxide, marking with alternate white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint and also including numbering of poles with white paint are located on different locations complete all as specified and directed by Engr-in-Charge.
M&L for replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 35/45 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable street light any type/any capacity including replacement of twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from junction box to LED light throgh copper connectos all as specified and directed. Make :- Havells/Bajaj/Philips
Description all as per item No 59 above but of size 60 Watt
Description all as per item No 59 above but of size 90 Watt
M&L for replacement of new generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 70 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable street light any type/any capacity including replacement of twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from junction box to LED light throgh copper connectos all as specified and directed. Make :- Havells/Bajaj/Philips
S&F in replacement of battery 12 volt lead acid suitable for solar street light having capacity 150 AH including all fitting arrangements all as specified & directed. Make:- Exide/Amaron/Luminous
M&L for structural MS frame work half round or other stock section including securing posts and stuts in fencing, frame work for gates of substations, base frame for equipments including securing bolts, posts and sturts in fencing including cutting and makeing shapes as desired, drilling holes, notching for wire cut to size and made to the exisitng shape suitable for fixing MS chequred duct covers / door panels, including nuts, bolts and washers, welding / bracing works, bending cold or hot drilling holes for bolts in any shapeetc flat iron fillets (for securing wire mesh etc) all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 including one coat of primer and two coats of synthetic enamel paint to the entire steel surfaces all as specified and directed.
M&L for chain link MS galvanised fencing including lines wires, dia of chain link n less than 3.5 mm any mesh any size any type to any type strands rails, straining bolts etc.
S&F mild steel screw bolt (mechine made) with hexagonal or square, head, n.exc 5 cm but n.ecx 10 cm dia.
M&L TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as directed.
S&F galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc as directed. Note - Each line of horizontal/vertical/diagonal wire to be measured for purpose of payment.
M&L MS angles as fencing port, struct cutting tops in shape incl all necessary drilling, notching and reveting etc and similar work confirming fe 310-0 pr fe 4120-0 all as specified and directed.
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP-31) 8.5 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with two coats of aluminium paint over one coat of red oxide primer and incl taking down existing old unserviceable poles complete all as specified and directed. (Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.) Note :- Excavation incl earth work and PCC foundation will be measured and paid separately.
Supply & fixing of single phase automatic street light switch using integrated sensor based NATURE SWITCH for automatic switching of street lights based on LUX level of natural light required illuminance for switching on is ‹ 30 Lux and for switching OFF › 10 Lux level. The sensor (nature switch) along with suitable power contactors input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof , termite proof and FR graded SMC junction box conforming of IP 54 degree of ingress single phase 8KW lightning load capacity including mounting bracket , cable glands, front openable doors fitted with hinges & locking arrangment complete all as specified and directed. The contactor MCB and circuit wiring should suitable enough to take load of 8 KW equally distributed over three phase and street light timer should be comprising of following:- (a). Input MCB rating 63 Amps (b).Contactor MCB rating 63 Amps (c).Out put MCB rating 63 Amps (d).Single phase circuit wiring minimum 16 Sqmm multistranded copper wire. (e)Model No :- SWADEEP -02EC 5 KW1P. Make :- Kakatiya Energy Systems Ltd
M&L PCC in mix 1:4:8 type D2 with 40 mm graded aggregate for poles / stays foundation and fitting in mass concrete
M&L for PCC 1:3:6 Type C2 for erection of pole in base with 40 mm gradede coarse agreegete complete all as specified and as directed.
M & L for road cutting incl necessary excavation 45 cm wide and 90 cm in depth as in trenches in any type of soils/rock for laying LT UG cable through pipe after laying /through the cable trenches will be filling top with M&L PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm bolders 100 mm dia over filled and rammed earth to make good the disburbed surface etc complete all as specified and directed.
S&F in replacement of LED street light used in solar street light operated DC 12 volt of capacity 25 Watt including all fitting arrangements all as specified & directed. Make:- Havells/Surya/TATA
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge.
M/S TP ENTERPRISES (BID ID -3134700)
M/s Roltso Enterprises (BID ID -3134707)
M/S MURPHEW ENTERPRISES (BID ID -3134711)
M/S SM ANSARI (BID ID -3134713)
M/S KUNKAPU ENTERPRISES (BID ID -3134712)
M/S R.N ENTERPRISE (BID ID -3134710)
M/S RAM AWADH SINGH (BID ID -3134704)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .