| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAdmitted-Finance MANTON SUPER MARKET STALL NO 16 GROUND FLOOR DIAMOND HARBOUR ROAD BEHALA KOLKATA 700034 | KOLKATA | WEST BENGAL | 700034 | ₹3.0 L | L1 | Admitted-Finance |
| 2 | L2₹3.0 LAdmitted-Finance 0 | ₹3.0 L | L2 | Admitted-Finance |
| 3 | L3₹3.1 LAdmitted-Finance | ₹3.1 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | GOUTAM ENTERPRISE L2 | NEON ENTERPRISE L1 | PRATIM ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.01 | TOTAL | 1 | Nos | 3,04,677.29 ₹3.0 L | 3,00,198.14 ₹3.0 L | 3,07,664.31 ₹3.1 L |
Tender Value
Refer Docs
EMD Value
₹6,000
Closing Date
14 Mar 2026, 5:00 pmClosed
EE(E) LTG HQ
Hudco building 8th floor,15 N. Nellie Sengupta Sarani , Kolkata -700087.
SUPPLY, DELIVERY AND INSTALLATION OF 2 NOS., 2.0 TON SPLIT-TYPE AIRCONDITIONING MACHINES AND OTHER ALLIED ELECTRICAL WORKS AT CHAMBER OF ASSTT. HEALTH MANAGER (ROOM NO.304) AND DIVISION-3C OF PERSONNEL DEPARTMENT, CMO BUILDING, UNDER KMC
2026_KMC_1019005_1
KMC/EE(E)/LTG/CMO/128/25-26
Open Tender
CIVIL WORKS
10 days
CMO BUILDING
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹6,000
23 Mar 2026
6 Mar 2026
16 Mar 2026
6 Mar 2026
14 Mar 2026
6 Mar 2026
TOTAL
Item Rate BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
SUPPLY AND INSTALLATION OF SPLIT TYPE ROOM AIR CONDITIONING MACHINE OF FOLLOWING TONNAGE CAPACITY 3 STAR RATING FITTED WITH ROTARY COMPRESSER AND COOLING CAPACITY MIN. 6000KCAL/HR.,MINIMUM DISCHARGE AIR FLOW 800 CUM MTR,800 EER(W/W) 2.7-2.89. (RATES ARE INCLUSIVE OF EXTRA REFRIGERANT PIPE DRAIN PIPE CONNECTING CABLE) UPTO THE SATISFACTION OF EIC. 2.0 TON (MAKE:HITACHI/VOLTAS/BLUE-STAR/DAIKIN OF 3 STAR NON-INVERTER TYPE. [SCHD:I&W DEPARTMENT,(M&E, DIRECTORATE), GOVT. OF WEST BENGAL, W.E.F. 10TH MAY, 2022, PG-118, ITEM NO.5.3 H.8.0.6].
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire brand(approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire FOR ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch brand(approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish [PVC casingcapping on surface and Switch board concealed] Average run 6 mtr
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand 6-32 A DP
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision FOR two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision FOR earthing attachment 2 Way
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire brand(approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(b)By TATA(Medium GI pipe
SUPPLY,INSTALLATION,TESTING & COMMISSIONING OF SUCTION / DISCHARGE COPPER PIPE LINE IN SPLIT AIR CONDITIONING UNIT 1.0 / 1.5 / 2.0 / 3.0 TON CAPACITY INCLUDING BRAZING , NITRILE RUBBER INSULATION 6/9 MM THICK CLASS 'O', ETC COMPLETE AS REQUIRED, COPPER TUBE-1/4". [SCHD: I & W. DEPARTMENT, (M & E, DIRECTORATE), W.E.F. 10TH MAY,2022, GOVT OF WEST-BENGAL,PG-117,ITEM NO.:5.3 H.4.1].
SUPPLY,INSTALLATION,TESTING & COMMISSIONING OF SUCTION / DISCHARGE COPPER PIPE LINE IN SPLIT AIR CONDITIONING UNIT 1.0 / 1.5 / 2.0 / 3.0 TON CAPACITY INCLUDING BRAZING , NITRILE RUBBER INSULATION 6/9 MM THICK CLASS 'O', ETC COMPLETE AS REQUIRED, COPPER TUBE-5/8". [SCHD: I & W. DEPARTMENT, (M & E, DIRECTORATE), W.E.F. 10TH MAY,2022, GOVT OF WEST-BENGAL,PG-117,ITEM NO.:5.3 H.4.4].
SUPPLY,INSTALLATION,TESTING & COMMISSIONING OF SUCTION / DISCHARGE COPPER PIPE LINE IN SPLIT AIR CONDITIONING UNIT 1.0 / 1.5 / 2.0 / 3.0 TON CAPACITY INCLUDING BRAZING , NITRILE RUBBER INSULATION 6/9 MM THICK CLASS 'O', ETC COMPLETE AS REQUIRED, COPPER TUBE-3/8". [SCHD: I & W. DEPARTMENT, (M & E, DIRECTORATE), W.E.F. 10TH MAY,2022, GOVT OF WEST-BENGAL,PG-117,ITEM NO.:5.3 H.4.2].
GAS CHARGING (R410A/ECO FRIENDLY GREEN GAS) OF WINDOW / SPLIT AIR CONDITIONING UNIT INCLUDING FLUSHING OF COOLING & CONDENSING UNITS WITH NITROGEN GAS & RECTIFICATION OF LEAKAGE, REPLACEMENT OF FILTER, FLAIR NUT ETC OF 2.0 TR. [SCHD : I & W DEPARTMENT, (M & E) DIRECTORATE, W.E.F. 10TH MAY, 2022, GOVT. OF WEST BENGAL, PAGE-117, ITEM NO.-5.3 H.5.3].
PROVIDING & FIXING OF ISI MARKED (IS:15778-2007) RIGID CPVC DRAIN WATER PIPING 6 KG/SQ CM WITH FITTINGS LIKE ELBOW,SOCKET,TEE ETC & SUPPORT WITH MS HANGER ON CEILING OR RECESSED IN WALL WITH CHASING & PLASTERING WITH 6MM THICK CLOSED CELL ELASTOMERIC NITRILE RUBBER INSULATION COMPLETE IN ALL RESPECT, 25 MM DIA. [SCHD: I & W. DEPARTMENT, (M & E, DIRECTORATE), W.E.F. 10TH MAY,2022, GOVT OF WEST-BENGAL,PG-117,ITEM NO.:5.3H.2(B)].
ERECTION AND INSTALLATION OF BOTH COOLING AND CONDENSING UNIT FOR 1.5 TON SAC AT RESPECTIVE LOCATION ON WALL ALONG WITH TERMINATION OF REFRIGERANT LINE AS PER DIRECTION OF EIC MENDING GOOD DAMAGED TO ORIGINAL FINISH
SUPPLY, DELIVERY AND INSTALLATION OF M.S. ANGLE IRON STRUCTURE TO PROVIDE ADEQUATE MECHANICAL SUPPORT FOR ODU AS PER DIRECTION OF EIC MENDING GOOD DAMAGE TO ORIGINAL FINISH
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 3 x 36/0.3 (2.5 sqmm) + 2 x 22/0.3 (1.5 sqmm) ECC
Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter brand(approved by EIC) with 25A Modular switch type DP MCB(c-curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.32 MB
BOQ_2503887.xls
BOQ • 0.37 MB
form.pdf
Tender Documents • 0.58 MB
Download all tender documents and submit your bid