| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.5 LAccepted-AOC PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹49.5 L+₹1.1 L (2.36%)Rejected-Finance VILL MOKHAWA TEHSIL GUDAMALANI DIST BARMER RAJASTHAN 344031 | GUDAMALANI | BARMER | RAJASTHAN | 344031 | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹55.4 L+₹7.0 L (14.6%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹57.2 L+₹8.8 L (18.3%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹61.9 L+₹13.5 L (27.9%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest |
| Sl No | Description | Qty | Unit | SHREE BHAGWATI ENTERPRISES L3 | DIVYA ASSOCIATES L6 | M/S Anil Enterprises L4 | M/s Yash Electrical and Maintenance L1 | tirumala contruction L5 | NAGEL ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down and dismantling defective transformer 11/0.433 KV of capacity 63 KVA from foundation/ pole by using crane and transporting to workshop or factory (authrorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete ,spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting to back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-in-Charge. | 2 | Each Job | 20,000 ₹40,000 | 15,000 ₹30,000 Lowest | 21,000 ₹42,000 | 30,000 ₹60,000 | 45,000 ₹90,000 | 21,000 ₹42,000 |
| 2.00 | Taking down and dismantling defective transformer 11/0.433 KV of capacity 100 KVA to 250 KVA from foundation/ pole by using crane and transporting to workshop or factory (authrorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting to back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-in-Charge. | 2 | Each Job | 25,000 ₹50,000 | 20,000 ₹40,000 Lowest | 26,000 ₹52,000 | 30,000 ₹60,000 | 55,000 ₹1,10,000 | 21,000 ₹42,000 |
| 3.00 | Taking down and dismantling defective transformer 11/0.433 KV of capacity 315 KVA to 630 KVA from foundation/ pole by using crane and transporting to workshop or factory (authrorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor, LV side, LT cable dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES NO with white paint of suitable size letter and transporting to back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-In-Charge. Note for ser item No 1 to 3 :- Spare parts i.e transformer oil, copper winding wire for rewinding will be measured and paid separately under relevant Items. | 2 | Each Job | 35,000 ₹70,000 | 30,000 ₹60,000 | 35,000 ₹70,000 | 35,000 ₹70,000 | 40,000 ₹80,000 | 25,000 ₹50,000 Lowest |
| 4.00 | S&F in repair of synthetic rubberised gaskets 4mm thick for top cover and other joints for transformer capacity 63 KVA to 100 kva ,11/0.433 KV complete all as specified and directed by Engineer-in-Charge. | 2 | Each | 1,500 ₹3,000 | 1,400 ₹2,800 | 1,300 ₹2,600 | 1,000 ₹2,000 Lowest | 2,500 ₹5,000 | 2,000 ₹4,000 |
| 5.00 | S&F in repair of synthetic rubberised gaskets 4mm thick for top cover and other joints for transformer capacity 160 KVA to 630 KVA ,11/0.433 KV complete all as specified and directed by Engineer-in-Charge. | 4 | Each | 2,000 ₹8,000 | 1,600 ₹6,400 | 1,500 ₹6,000 Lowest | 1,500 ₹6,000 Lowest | 3,500 ₹14,000 | 2,000 ₹8,000 |
| 6.00 | M&L for taking out unserviceable core and limb and HV/LV winding of transformer and taking out burnt copper winding wire cleaning carefully an rewinding the same with new superior quality 99.99% pure copper enamelled wire as per existing gauge including insulating material for transformer 25 KVA to 630 KVA complete all as specified and directed by Engineer-in-Charge. | 570 | KG | 900 ₹5,13,000 Lowest | 1,050 ₹5,98,500 | 950 ₹5,41,500 | 950 ₹5,41,500 | 1,500 ₹8,55,000 | 1,000 ₹5,70,000 |
| 7.00 | Dehydration of transformer oil (mounted on poles/platform etc) with the help of filtering and drying plant by mechanical machines of suitable capacity to achieve dielectric strength of 50 KV complete all as specified and directed by Engineer-in-Charge. Note : For any capacity of Transformer | 15,000 | Ltr | 15 ₹2,25,000 | 15 ₹2,25,000 | 11 ₹1,65,000 | 10 ₹1,50,000 | 8 ₹1,20,000 Lowest | 12 ₹1,80,000 |
| 8.00 | Supply only transformer oil for topping up of transformers any capacity all as conforming to IS - 335 at different transformers & different locations complete all as specified and directed by Engineer-in-Charge Note : The dielectric strength of the transformer oil must be 45 KV r.m.s (min). Make : Power oil/HP/BP make as approved by GE. Note : Test certificate in respect of the same to be submitted by the contractor duly signed by the Engineer-in-Charge. | 2,800 | LTR | 150 ₹4,20,000 | 280 ₹7,84,000 | 152 ₹4,25,600 | 130 ₹3,64,000 Lowest | 160 ₹4,48,000 | 180 ₹5,04,000 |
| 9.00 | S&F in repair of unserviceable HT brass stem with nuts, washers of transformer 63 KVA to 630 KVA complete all as specified and directed by Engineer-in-Charge | 12 | Each | 600 ₹7,200 | 800 ₹9,600 | 700 ₹8,400 | 500 ₹6,000 Lowest | 1,500 ₹18,000 | 1,000 ₹12,000 |
| 10.00 | S&F in repair of unserviceable LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 25 KVA to 63 KVA complete all as specified and directed by Engineer-in-Charge | 8 | Each | 400 ₹3,200 Lowest | 600 ₹4,800 | 500 ₹4,000 | 1,500 ₹12,000 | 1,200 ₹9,600 | 1,000 ₹8,000 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
17 Feb 2026, 6:00 pmClosed
CWE (A) Jaisalmer
HQ CWE ARMY JAISALMER 345001 RAJASTHAN
REPAIR/MAINT OF DISTRIBUTION TRANSFORMER, VOLTAGE STABILIZER AND ALLIED WORKS AT JAISALMER STATION UNDER GE (A) JAISALMER
2026_MES_746993_2
84382/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
JAISALMER
AS PER NIT
8 documents required · 8 mandatory
₹500
GE ARMY JAISALMER
₹1 L
Yes
12 Mar 2026
5 Feb 2026
19 Feb 2026
5 Feb 2026
17 Feb 2026
12 Feb 2026
5 Feb 2026 - 7 Feb 2026
Taking down and dismantling defective transformer 11/0.433 KV of capacity 63 KVA from foundation/ pole by using crane and transporting to workshop or factory (authrorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete ,spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting to back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-in-Charge.
Taking down and dismantling defective transformer 11/0.433 KV of capacity 100 KVA to 250 KVA from foundation/ pole by using crane and transporting to workshop or factory (authrorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting to back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-in-Charge.
Taking down and dismantling defective transformer 11/0.433 KV of capacity 315 KVA to 630 KVA from foundation/ pole by using crane and transporting to workshop or factory (authrorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor, LV side, LT cable dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES NO with white paint of suitable size letter and transporting to back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-In-Charge. Note for ser item No 1 to 3 :- Spare parts i.e transformer oil, copper winding wire for rewinding will be measured and paid separately under relevant Items.
S&F in repair of synthetic rubberised gaskets 4mm thick for top cover and other joints for transformer capacity 63 KVA to 100 kva ,11/0.433 KV complete all as specified and directed by Engineer-in-Charge.
S&F in repair of synthetic rubberised gaskets 4mm thick for top cover and other joints for transformer capacity 160 KVA to 630 KVA ,11/0.433 KV complete all as specified and directed by Engineer-in-Charge.
M&L for taking out unserviceable core and limb and HV/LV winding of transformer and taking out burnt copper winding wire cleaning carefully an rewinding the same with new superior quality 99.99% pure copper enamelled wire as per existing gauge including insulating material for transformer 25 KVA to 630 KVA complete all as specified and directed by Engineer-in-Charge.
Dehydration of transformer oil (mounted on poles/platform etc) with the help of filtering and drying plant by mechanical machines of suitable capacity to achieve dielectric strength of 50 KV complete all as specified and directed by Engineer-in-Charge. Note : For any capacity of Transformer
Supply only transformer oil for topping up of transformers any capacity all as conforming to IS - 335 at different transformers & different locations complete all as specified and directed by Engineer-in-Charge Note : The dielectric strength of the transformer oil must be 45 KV r.m.s (min). Make : Power oil/HP/BP make as approved by GE. Note : Test certificate in respect of the same to be submitted by the contractor duly signed by the Engineer-in-Charge.
S&F in repair of unserviceable HT brass stem with nuts, washers of transformer 63 KVA to 630 KVA complete all as specified and directed by Engineer-in-Charge
S&F in repair of unserviceable LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 25 KVA to 63 KVA complete all as specified and directed by Engineer-in-Charge
S&F in repair of unserviceable LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 100KVA to 250 KVA complete all as specified and directed by Engineer-in-Charge
S&F in repair of unserviceable LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 315KVA to 630 KVA complete all as specified and directed by Engineer-in-Charge
S&F in repair of unserviceable breather assembly with new silica gel of transformer 11/0.433 KV of capacity 25 KVA to 100 KVA complete all as specified and directed by Engineer-in-Charge
S&F in repair of unserviceable breather assembly with silica gel of transformer 11/0.433 KV of capacity 160 KVA to 630 KVA complete all as specified and directed by Engineer-in-Charge
S&F in repair of porcelain transformer bushing 11 KV suitable for transformer 63 KVA to 100 KVA complete all as specified and directed by Engineer-in-Charge
S&F in repair of porcelain transformer bushing 11 KV suitable for transformer 160 to 630 KVA complete all as specified and directed by Engineer-in-Charge
S&F in repair of porcelain transformer bushing 433 volts suitable for transformer up to 100 KVA complete all as specified and directed by Engineer-in-Charge
S&F in repair of porcelain transformer bushing 433 volts suitable for transformer 160 KVA upto 630 KVA complete all as specified and directed by Engineer-in-Charge
S&F in repair tap changer suitable for 11/440 KV transformer of capacity 63 to 630 KVA complete all as specified and directed by Engineer-in-Charge.
S&F in repair dimmer suitable for voltage stablizer 50 kva complete all as specified and directed by Engineer-in-Charge. Make :- Digitec
S&F in repair dimmer suitable for voltage stablizer 75 to 100 KVA complete all as specified and directed by Engineer-in-Charge.
S&F in repair servo motor 10 Kg / Sqcm suitable for voltage stablizer 50/75 KVA (3x25) complete all as specified and directed by Engineer-in-Charge
S&F in repair PCB, including carben bush, limit swith, push button etc suitable for voltage stablizer 50/75 KVA (3x25) complete all as specified and directed by Engineer-in-Charge
Supply, Jointing and testing indoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 95 Sqmm 3 core 11 KV under ground XLPE cable complete and including taking down old unserviceable complete all as specified and directed by Engineer-in-Charge.
All as per item No. 24.00 here-in-before above but 120 Sqmm to 185 Sqmm 3 core
Supply, Jointing and testing outdoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 95 Sqmm 3 core 11 KV under ground XLPE cable completeand including taking down old unserviceable complete all as specified and directed by Engineer-in-Charge
All as per item No. 26.00 here-in-before above but 120 Sqmm to 185 Sqmm 3 core.
Supply jointing and testing straight through heat shrinkable joint kit 11 KV unearthed grade suitable for size 95 Sqmm 3 core 11 KV under ground XLPE cable complete and including taking down old unserviceable complete all as specified and directed by Engineer-in-Charge
All as per item No. 28.00 here-in-before above but 120 Sqmm to 185 Sqmm 3 core.
M&L for Re-stringing and re-connection of ACSR of any size duly binded with insulators, jumpers etc.(fixed on 9/11mtr poles) complete all as specified and directed by Engineer-in-Charge Note :- (i) The above work includes cleaning pruning of tree branches falling around the conductors (ii) One length shall be measured for complete span of 3/4/5/6 conductors & GI wire.
M&L for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (12 Insulators Vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old unserviceable switch air break gang operated complete all as specified and directed by Engineer-in-Charge
M&L for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (09 Insulators Vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old unserviceable switch air break gang operated complete all as specified and directed by Engineer-in-Charge.
M&L for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (09 Insulators Horizental type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old unserviceable switch air break gang operated complete all as specified and directed by Engineer-in-Charge. Note :- stack for fixing with poles shall be measure and paid separately
S&F in repair pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed by Engineer-in-Charge
S&F in repair disc type insulator, porcelain, vitreous with hardware, 145mm high and 255mm dia ball and socket type, white, brown or green, single disc assembly for 11000 volts grade complete all as specified and directed by Engineer-in-Charge
Taking down old HT under ground cable of any size and any description etc complete all as specified and as specified and directed by Engineer -in- Charge.
Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 95 sqmm 3 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 120 sqmm 3 core complete all as specified and directed by Engineer-in-Charge
Supply, laying & testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 185 sqmm 3 core complete all as specified and directed by Engineer-in-Charge
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in Soft/disintegrated rock complete all as specified and directed by Engineer-in-Charge
Returning, filling in, including, spreading, levelling, watering and well ramming excavated Soft/Disintegrated rock in layers complete all as specified and directed by Engineer-in-Charge
Removing excavated Soft/Disintegrated rock to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge
Supply and laying DOUBLE WALLED CORRURATED DWC pipe 90 mm bore as per IS-16205 part-24 for cable protection including all fittings as required and also including taking down old unserviceable pipe complete all as specified and as specified and directed by Engineer -in- Charge.
M&L for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified and directed by Engineer-in-Charge.
S&F in repair GI pipe light grade of dia 80 mm laying in road and along with poles for cable protection complete all as specified and directed by Engineer-in-Charge.
M&L for painting tranformer complete by removing existing oil paint by scrapping and applying two coats of approved colour synthetic enamel paint (1st grade quality) over a coat of primer after preparation of surfaces including writing SM / MES numbers and date of oil tested etc. all as directed by Engr-In-Charge and applying one coat of cement base paint on transformer plinth for the following capacity complete all as specified and directed by Engineer-in-Charge. :-
Transformer of capacity 63 KVA, 11 KV/0.433 KV.
Transformer of capacity 100 KVA to 200 KVA, 11 KV/0.433 KV.
Transformer of capacity 250 to 630 KVA, 11 KV/0.433 KV.
Servicing the 11 KV GOD by cleaning the contact, disc/ pin insulator with CTC and applying the petroleum jelly at the contact point/ down rod links for smooth operation including replacing the rusted/ corroded bolts & nuts and defective insulator of GOD as required complete all as specified and directed by Engineer-in-Charge. Note :- Insulator shall be measured and paid under relevant items of this schedule.
S&F Male/ Moving contact (set of 3 Nos) complete all as specified and directed by Engineer-in-Charge.
S&F Female/ Fixed contact (set of 3 Nos) complete all as specified and directed by Engineer-in-Charge.
Dismantling, taking down and removing the old existing unserviceable non-functional/broken hinges of any description and in any postiion of existing feeder piller boxes/panel boards/feeder pillar boxes etc and supplying and fixing new cold rolled 100mm long medium weight mild steel but hines in position with necessary spot welding etc including external part of full panel shall be painted with two coat of synthetic enamled paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. Note : All Hinges fixed in one panel will be considred under one job only.
Cuttting / trimming of tree branches in close proximity to over head lines to maintain a clearance of 1.5 meters from the over head line to nearby trees complete and removing/ throughing the cutting branches to distance not exceeding 50 m or as complete all as specified and directed by Engineer-in-Charge. Note :- Only effected area of over head conductor shall be measured as per running meter.
S&F feeder Piller Box outdoor type single door front openable in two half not less than 1.20mx1.20mx1.00m made out of 3.15 mm thick CRCA sheet podwer coated paint in heat process of sheet, supported on angle iron frame 50x50x6mm having legs 1.2,mtr long grouted in PCC upto 60cm, aluminium bus bar 03 Nos rated capacity 200A (HT) duly insulated 11000 Volt grade for phases supported on HT porcelain/Polymer/Composite insulator , PCC foundation 1:2:4 (using 20mm graded stone aggregate) complete all as specified and directed by Engineer-in-Charge.
M&L for bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron strip 32 x 6 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 (using 20mm graded stone aggregate) with handle and 20mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed by Engineer-in-Charge.
M&L for Shifting of Existing Transformer of capacity 63 KVA to 315 KVA from one sub station to another sub station under E/M-II sub division by using crane after disconnection of LT & HT side connections complete all as specified and directed by Engineer-in-Charge.
S&F cable route indicators made out of hammer dressed stone slab of size 30 cm (L) x x7.5 cm (B) x 90cm (H) and applying two coats of white synthetic enamel paint and marking of voltage and size of cable in RED COLOUR including necessary eatth work, PCC required to fix complete all as specified and directed by Engineer-in-Charge. Note : Earth work, PCC deemed to be included in quoted rate.
M&L for finding cable fault with electronic fault detector in HT UG cable of any size complete including earthwork and jointing cable complete all as specified and directed by Engineer-in-Charge.
Removing grass and bushes including its roots growing at Substation yard/around the platefarm of transformer/ two poe/4 pole structure and keep the sub station yard/ plate farm area neat and clean cable complete all as specified and directed by Engineer-in-Charge.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_841647.xls
BOQ • 0.32 MB
RTENDER_84382.pdf
Tender Documents • 3.47 MB
RNIT.pdf
Additional Documents • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .