Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹40.0 L+₹4.2 L (11.8%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹41.5 L+₹5.8 L (16.1%)Rejected-AOC | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹41.7 L+₹5.9 L (16.5%)Rejected-AOC 275 2 AJIT NAGAR UPPER GADIGARH AIRPORT ROAD JAMMU 181101 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181101 | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | L5₹41.7 L+₹6.0 L (16.6%)Rejected-AOC | L5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹48.3 L
EMD Value
₹96,650
Closing Date
17 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Tanuj Bagla, IDSE, EE
GE kaluchak Pin-900673 C/O 56 APO
SPL REPAIR TO BLDG NO SPL REP TO BLDG NO P-426-1 TO P-426-6 (OR MD ACCN) OF SIKH LI AND PROVN OF DRAIN BEHIND (COOK HOUSE) BD BARI AND PROVN OF DRAINAGE ARMD BDE AND PROVN OF MT GARAGE B VEH OF ARMD BDE PRO UNIT AT MIL STN RATNUCHAK UNDER GE KALUCHAK
2024_MES_675360_1
GE/KC-56/2024-25
Open Tender
Civil Works
Item Rate
120 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE kaluchak
₹96,650
Yes
14 Jan 2025
19 Sept 2024
19 Oct 2024
19 Sept 2024
17 Oct 2024
3 Oct 2024
19 Sept 2024 - 26 Sept 2024
Amount
Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition and breaking up drain pipes of any size (salt glazed stoneware, AC or reinforced concrete) set in cement mortar complete all as specified and directed.
Dismantling of any size cast iron or reinforced concrete drain pipe, jointed in cement mortar, fixed withj wall and taking out of trenches, if required complete all as specified and directed.
Excavation over areas not exc. 1.50 m deep and getting out in any type soil complete all as specified and directed.
Excavation over areas exc. 1.50 m but not exc. 3.00 m deep and getting out in any type soil complete all as specified and directed.
Surface dressing n exc 15 cm deep in any type soil complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type soil complete all as specified and directed.
M&L for earth filling under floor ,spreading and levelling in layers n exc. 25 cm thick well ramming including watering as requiredcomplete all as specified and directed.
M & L for loose filling of broken brick bats of gauge 80 to 150 mm as in soakage pits, soakage wells complete all as specified and directed.
M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed
Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
M & L for providing pre-cast cement concrete in door or window cills, lintel, bressumers, bed plat, apex stone, pintle blocks, bonders (For stone masonry) and similar items with plain faces including chamfers, weathering, throating etc. in cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate and setting in cement mortar 1:6 complete all as specified and directed.
M & L for providing 50 mm thick pre-cast cement concrete louvers or RCC Jali made out of cement concrete 1:2:4 type B-0, using 12.5 mm graded stone aggregate and set in cement mortar 1:4 including all mouldings etc. complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for providing plain cement concrete, type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in sunken, filling and mass concrete complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate as in surface channel or drain complete all as specified and directed.
M & L for providing plain cement concrete type B-1, 1:2:4, (using 20 mm graded stone aggregate), as in benching,water throughts etc and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for providing pre-cast cement concrete landing, cover slabs, chullah hoods, chajjas, shelves and similar items with plain faces in cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate and setting in cement mortar 1:4 complete all as specified and directed.
M & L for providing plain cement concrete type B-0, 1:3:6, (using 12.50 mm graded stone aggregate), as in filling of pressed steel door frames/chowkats complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), as Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix),as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed.
M & L for providing reinforced cement concrete M-25 (Design Mix), using 20 mm graded stone aggregate, as in columns, pillars, piers, posts, struts and the like complete all as specified and directed.
M & L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks, straight or curved on plan and any radius in one and half brick thick honeycomb wall built in cement mortar 1:6 complete all as specified and directed.
M & L for brick work with sub class ‘B’ old size bricks in one brick thick honeycomb wall built in cement mortar 1:4 complete all as specified and directed.
M & L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in fair finished surface of concrete complete all as specified and directed.
M & L for form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed..
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in fair finished surface of concrete complete all as specified and directed.
M & L form work to sides of pillars, posts, struts, piers, columns and stanchions in fair finished surface of concrete complete all as specified and directed.
M & L for Formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
S & F of solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet as per specification and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
S & F of 35mm thick 2nd class hard wood (Sal/Hollock), glazed and skeleton shutters (factory made), open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., size of members of shutters as specified in clause 8.24 (a) of SSR Part-I, complete all as specified and directed.
S & F of 35mm thick factory made 2nd class hard wood (Sal/ Hollock) plain, framed, panelled shutters (two panels) with lock rail and panels of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial face veneers on both sides.The size of rail and style as per IS–1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified & directed.
S & F of factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles) with particle board core an 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
S & F of 300 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy complete all as specified and directed.
S & F of 100 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S & F of 30 mm wide flap when open, mild steel bright finish or electro galvanised continuous (Piano) hinge complete all as specified and directed.
S & F of 150 mm long anodised aluminium handle, cast type complete all as specified and directed.
S & F of 150 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S & F of Galvanised mild steel wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staplescomplete all as specified and directed.
S & F of 300 mm mild steel ordinary rat tail, rod pattern springs including roller and roller plate complete all as specified and directed.
S & F of 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and directed.
S & F of 100 mm size aluminium anodised Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
S & F of 140 mm size (Overall length of cover plate) floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F of Factory made box type steel windows comprised of tubular frame and shutters made out of 1.25mm thick MS sheet tube with double side shutters (Wire Gauged shutter and Glazed Shutter), side hung shutters with MS handles and MS stays dovetailed or welded including 02 nos MS Tower Bolt 150mm long for each leaf, 8 mm square guard bars at spacing as shown in drawings, MS flat iron frame work, MS hinges, tarred hold fast, PCC 1:2:4 type B1 as in bed of hold fast, 01 No. per leaf of stopper of 100mm size, one coat of red oxide zinc chrome primer etc, complete all as specified and shown as drawing No. CEPZ/TD-354/09 sheet 1/3 to 3/3. NOTE : a). Wire cloth and Sheet glass shall be measured and paid seprately under respective items. b). Rate of both type of shutters is inclusive in the quoted rate.
S & F steel ventilator with top hung shutter including hinges, steel peg stay, complete including one shop coat of red oxide zinc crome primer, complete all as specified & directed. complete all as specified and directed .
S & F of mild steel framed work such as gate grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
S & F of pressed steel frames of size 125mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate., complete all as specified & directed. NOTE : PCC for filling of hollow portion shall be measured and paid for separately.
S & F of pressed steel frames of size 105 mmx60mm made of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate., complete all as specified & directed. NOTE : PCC for filling of hollow portion shall be measured and paid for separately.
S&F of Magnetic catcher, heavy duty, brass body and striking plate, fixed in cupboard shutters, complete all as specified & directed.
M & L for 15 – 18 mm thick Machine cut kota stone slab, as per sample kept in GEs office as in vertical surfaces such as skirting/dado etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing, laid over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-1, using 20 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm thick joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by weight) complete all as specified and directed.
M & L for 25 mm thick cement concrete 1:2:4 type B-2, using 20 mm graded stone aggregate as laid in alternate bays finished the surface even and fair without using extra cement complete all as specified and directed.
M & L for 100 mm thick cement concrete 1:4:8 type D-2, using 40 mm graded stone aggregate as in sub base cement complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, and brushing neat cement slurry with 3.0Kg of cement per square metre, complete all as specifed & directed.
Excavation over areas exc 3 m but n.exc 4.50 m deep and getting out in any type of soil complete all as specified and directed.
M & L for providing 150 mm thick cement concrete 1:2:4 type B-1 (using 20 mm thick graded stone aggregate) as in floor laid in alternate bays, finishing top surface even and smooth with using extra cement and making spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified and directed .
M & L for 15 to 18 mm thick granite (of any type and shade) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including necessary cutting, grinding, rubbing, polishing rounding to exposed edges and laid over20 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed.
M & L Non - skid joint free Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - SCREED SHALL BE MEASURED AND PAID SEPARATELY.
M & L for Glazed ceramic coloured tiles in vertical surface 450x300X 7mm thick ,on ventical surface as in skriting , dado set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - RENDERING SHALL BE MEASURED AND PAID SEPARATELY.
M & L Non - skid joint free ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - SCREED SHALL BE MEASURED AND PAID SEPARATELY.
M & L Non - skid Ceramic joint free coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. NOTE: - RENDERING SHALL BE MEASURED AND PAID SEPARATELY.
Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and smooth (without using extra cement)complete all as specified and directed.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth (without using extra cement)complete all as specified and directed.
M & L for 5 mm thick rendering on fair faces of brick work or concrete surfaces of ceiling with cement mortar 1:3 finished even and smooth (without using extra cement)complete all as specified and directed.
M & L for 15 mm thick rendering on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and smooth without using extra cement using integral water proofing compound as per manufacturer,s instructions , complete all as specified & directed. NOTE:- Integral water proofing compound shall be measured & paid seprately.
Supply only water proofing compound ( (Liquid) complete all as specified.
M & L for washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified complete all as specified and directed.
M & L for 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes finished even and rough complete all as specified and directed.
M & L for 10 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4 on vertical surfaces of wall finished even and rough suitable for laying wall tiles complete all as specified and directed.
S & F of 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
S & F of 3 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane with oil putty or fixed with beads complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparation of old decorated plastered or unplastered surfaces of ceiling, cornices etc by brooming down or steel wire brushing down scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, and applying one coats of white wash complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of walls, cornices etc by brooming down or steel wire brushing down scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, and applying one coats of cement base paint complete all as specified and directed. NOTE:-The work will be carried out upto triple storey buildings and the cost of scaffolding is also included in this items
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coat of oil bound distemper over a coat of 1 mm thick birla wall care putty complete all as specified and directed. NOTE:-The work will be carried out upto triple storey buildings and the cost of scaffolding is also included in this items.
M & L for complete removal of old finishes from wall by scrapping, rubbing down, with sand paper to have even and smooth surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparation of old decorated plastered or unplastered surfaces of wall, cornices etc by brooming down or steel wire brushing down scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots, and applying one coats of weather proof paint complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces. and applying two coats of ‘Apex’ of Asian paint or ‘Weather coat’ of Berger Paints over one coat of primer complete all as specified and directed. NOTE:-The work will be carried out upto triple storey buildings and the cost of scaffolding is also included in this items
M & L for preparation of new or previously untreated wooden surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparation of steel surfaces over n.exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M & L for 40 mm dia high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches complete all as specified and directed.
M & L for cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in bed to drain pipes of 150 mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
S & F of 150 mm bore reinforced concrete pipe class NP-2 laid, jointed with collar in neat cement slurry complete all as specified and directed.
Taking up or down 15 mm bore steel water tubing and connection, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing and connection, including cleaning for refixing or removal to store complete all as specified and directed.
Cutting existing steel tubing for alterations or additions (Each cut measured) complete all as specified and directed.
Screwing existing steel tubing for alterations or additions (or lengthening screw on pipe to form connector)
S&F 15mm nominal bore of pipe in walls, and ceiling or laid in floors, jointing and testing galvanised mild steel water tubing “medium grade” with and including all fitting (such as bends, elbows, tees, short pieces connectors, back nuts, diminishing pieces, capas, plugs and union etc) complete all as specified and directed.
S&F 20 mm nominal bore of pipe in walls, and ceiling or laid in floors, jointing and testing galvanised mild steel water tubing “medium grade” with and including all fitting (such as bends, elbows, tees, short pieces connectors, back nuts, diminishing pieces, capas, plugs and union etc) complete all as specified and directed.
S & F in repair 15 mm bore chromium plated,fancy type bib tap, cast copper alloy with capstan heads, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F of 15 mm bore fancy type, chromium plated stop valve, with long shank and cup (Concealed Type) cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repair fancy type stop cock with flange, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, externally threaded, screwed both ends for iron pipe or for unions of 20 mm bore complete all as specified and directed.
S&F stop cock (valves), cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, externally threaded, having weight @ 0.40 Kg/Each, ISI certification marked with IS : 881, screwed both ends for iron pipe or for unions of 15mm bore complete all as specified and directed.
S & F in repairs 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
S & F of 125 mm dia grating doom with waste hole of PTMT (minimum weight 40 gram) complete all as specified and directed.
S & F of chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union size 125 mm complete all as specified and directed.
S & F in repair 20 mm dia aluminium anodised tubular curtain rail , including one pair of fixing brackets complete all as specified and directed.
S & F in repair 20 mm dia brass chromium plated tubular towel rail 'D' type 60 cm long between flanges, including one pair of fixing brackets complete all as specified and directed.
S&F 15 mm bore angle stop valve cast copper alloy,CP with capstan heads, fancy type any colour high pressure screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S & F in repairs water closet vitreous china squatting pan ‘Orrisa’ pattern size 580 X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe, anti-syphonic pipe etc. with and including setting the trap and pan in lime concrete bedding (one lime, two sand or surkhi and 5 aggregate) minimum 150 mm thick alround and finished just below level of rim of pan to receive the floor finishes complete including making good floor complete all as specified and directed.
S & F in repair polymer white (polypropylene Delrin and ABS) low level flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, flush pipe, brass screws, handle etc complete having BIS description mark with IS: 7231 with and including 32 mm bore PVC flush pipe of suitable length complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to wall /floor complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) junction single, (Single ‘T’) equal or unequal complete all as specified and directed
S & F of 110 mm bore PVC (SWR) Slotted vent cowl complete all as specified and directed
S & F of 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to wall complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) junction single, (Single ‘T’) equal or unequal complete all as specified and directed
S & F of 75 mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
S & F of 75 mm dia PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed.
M&L for water proofing treatment to sunken portion with 15mm thick rendering in cement mortar 1:3 using integral water prooofing compound both on floor and walls including preparation of surface by making free from all loose particles, surface cured and allowed to dry, apply a coat of Moisture Cured High Tensile Elastomeric Modified Poly Urethane based liquid membrance coating as per manufacturers instructions both on floor as well on walls, sunken slab shall be laid to a slope of 1:40 outwards with 25mm dia PVC pipe spout projecting at least 45mm beyond out face of wall, complete all as specified & directed. Notes : a) PVC spout 25mm dia, PCC 1:4:8 type D2 and WC / EWC shall be measured and paid for separately under respective items. b) Ponding shall be done in sunken portion area by filling water which shall be kept there for one week. In case a slightest indication of seepage /leakage is noticed, the same shall be rectifird by grounting the effected area at no extra cost. Thereafter, ponding shall be repeated till there is no indication of seepage/leakage. The arrangements of ponding to be included in quoted rates and nothing shall be admissible on this account.
Material & Labour for RCC chajja/fascia/parapet repair by using following steps :- (a) Removal of existing concrete along with loose damaged and cracked concrete/cover concrete from chajjas etc, exposing corroded steel reinforcements upto a depth of 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting to chipped concrete and reinforcement all as directed by Engineer-in-charge. Hard concrete shall not be removed. However if the rebar is corroded, concrete around it shall be removed. (b) Cleaning the surface of reinforcement bars from dust by using wire brushes and dry cloth and applying FOSROC Rebakleens RR- Rust Remover or equivalent using small brush and allow to react it for 16-24 hrs. (c) Providing and applying two coats of Fosroc Nitozinc Primer - two component, zinc rich epoxy, anti-corrosive protective coating or equivalent by brushes to the exposed and cleaned rebars with an interval of 45minutes to 1 hour @ 40microns DFT / coat and allowed to completely dry for 24 hours all as directed by Engr-in-Charge.
(d) Cleaning the concrete surface thoroughly once again using wire brush and applying one liberal coat of Fosroc Nitobond EP- two component Epoxy bonding agent or equivalent to the parent concrete with brush. (e) Providing and applying 50 mm thick Renderoc SP 40 - or equivalent Polymer modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar after mixing of Renderoc SP 40 or equivalent with recommended qty. of water using slow speed drill fitted with mixing paddle and then applying the same to prepared surface and finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface all as directed by Engr-in-Charge. Note : Item rate is inclusive of all materials, labour, tools and plants, scaffolding and transportation etc. complete as per specifications and as directed by Engr-in-Charge
M&L for preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b) Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm. (d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding material with blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm. (f) Applying a coat of bitumious based aluminium
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed.
Taking down carefully existing sub main wiring complete of any size and capacity complete all as specified and directed.
Taking down carefully unserviceable main switches, DBs including MCBs etc. complete of any size and capacity complete all as specified and directed.
Taking down electronic / electric meter single phas any size or type from the existing site and refixing the same at same place after carrying out necessary repair work and making the surface good to match with existing surface with proper concealed connections on the same and testing after complete of reading complete all as specified and directed
M&L for point wiring one light / fan/ bell/Exhaust fan point controlled by one way switch(concealed type) complete with multi stranded copper conductor flame retardant low smoke (FRLS) 1.5 Sqmm size PVC insulated unsheathed cable 1100 volts grade drawn through with and incl medium grade duty concealed PVC conduit ISI marked not less than 20mm dia including conduit fittings and accessories such as socket,elbow,junction box, bell mouth,bend, reducer etc complete incl cutting chases in existing walls of any description built in cement mortar and making good the disturbed surfaces in cement mortar (1:4) and finishing the surfaces to match with existing surfaces and finish with using sunken type pressed steel terminal boxes of required sizes of not less than 1.6 mm thick factory made and factory painted with top cover of 3 mm thick plastic laminated sheet fixed with brass screws washers with all accessories including single core multi stranded copper conductor 1.5 Sqmm size PVC insulated unsheathed cable green in colour as earth wire to common earth and connected to earth dolly drawn in same conduit complete all as specified . NOTE :-Wire/Cable colour coding Shall be maintained properly as per IE rule.
All as per item No 132 but for one 3/5 pin socket outlet 5 Amps on the same board with other switches.
All as per item No 132 but for one 3/5 pin 5 Amp socket outlet on independent board.
All as per item No 132 above here in before but with 4.0 Sqmm (nominal area) cable PVC insulated but unsheathed for the 15 Amp 3/5 pin socket power point including 2.5 Sqmm copper conductor green in colour for earth continuity on independent board complete all as specified and directed.
S&F switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type complete all as specified and directed.
S&F Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed.
S&F bell push flush type 5 Amps complete all as specified and directed.
S&F Ding Dong musical AC. 230 volts,single pole complete all as specified and directed.
S&F Ceiling rose three teminal /PVC/ polycarbonate, insulated body complete all as specified and directed.
S&F electronic fan regulator, 100 watt, (5 stepped type), 240 Volt for 1200/1400 sweep AC ceiling fan complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including one LED retrofit Lamp of B-22 holders base warm white Code No LHLDRUEML8X005 of make Havells or equivalent make of Phillips/Crompton etc complete all as specified and directed.
Supply and fixing factory made epoxy powder coated distribution board, SPN, 12 ways with metal door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for one SPN/DP MCB as incomer and SP MCB outgoing, complete all as specified & directed .
Supply and fixing factory made epoxy powder coated distribution board, VTPN, 4 ways with metal door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for one one SPN/DP-MCB as incomer and SP MCB outgoing, complete all as specified & directed .
Supply and fixing factory made epoxy powder coated distribution board, VTPN, 4 ways with metal door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 200 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for one one FP- MCCB 160/250 Amp as incomer and SP MCB outgoing, complete all as specified & directed .
Supply and fixing factory made epoxy powder coated distribution board, SPN, 2 ways with metal door (IP-43 protection), confirming to IS : 8623 fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall, suitable for universal mounting including 100 Amp copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts, suitable for one SPN/DP MCB as incomer and SPN/DP- MCB outgoing, complete all as specified & directed .
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 63 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified & directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified & directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified & directed.
S&F in replacement of MCCB 63 Amps four pole 415 volts thermal magnetic release ICU=100% ICS having breaking capacity 16 KA including connection terminal strip complete all as specified & directed.
M&L for sub main wiring with 2 Single core PVC insulated unsheathed FRLScable 1100 Volts grade heavy duty copper conductor multistranded of size6.0 Sqmm (nominal area) drawing in and including 25 mm dia or higher medium duty PVC concealed conduit and conduit accessories and fittings. including one single core green colour PVC Insulated unsheathed FRLS cable copper conductor multistranded of size 4.0 Sq mm as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
M&L for PVC insulated weather prof flat twin core aluminium cable of size 1.50 sqmm single core including with PVC conduit of all necessary suitable iron clamps (03 Nos) nut and bolts of approprite size from juncation box to street light complete all as specified & directed
Supply, hanging and testing of BEE 5 Star rated energy efficient brushless direct current motor (BLDC) ceiling fan, 1200mm (48 inch) sweep, having 3 blades made of aluminium alloy, down rod, canopies, shackles, 240 volt, single phase suitable for input voltage range 140-285 volts, AC, 50Hz, power factor not less than 0.99, service value minimum 8 cubic metre / min/ watt or higher, air delivery minimum 230 cu metre/ min or more, power consumption maximum 28 watt or lower, top speed minimum 340 RPM or higher, THD not more than 10% including 5 step electronic regulator marked on rotating knob, two module, 100W, 240 volts with 3 years on site warranty for speed control, copper winding, complete as per IS:374-1979 or latest IE rule & site requirement, colour white complete and taking down old unserviceable fan of any type/ size from existing location and depositing in MES storeyard, complete all as specified & directed.
Supply & fixing metallic exhaust fan, 300mm (12") sweep, single phase, 230 volts, 50 Hz AC, 1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings, complete with louvers and shutters, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable including cutting holes in existing brick walls for making opening for fixing of exhaust fan of 300mm sweep including grounting bolts/nuts ,MS Jali made of 3 mm dia MS wire 50 mm apreature fixed with and including proper wooden frame at outer surface of wall and making good disturbed surface of walls using cement sand mortar 1:4, complete all as specified & directed.
Supply, installation and testing of water heater storage type (Geyser) single phase, 230V, 50Hz, 5 star energy saving, high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 25 Litre capacity, 2000 Watt rated power, incoloy 800 glass coated heating element, tank coating of ferro glass dry powder tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up fixed to walls by drilling of holes, grouting of bolts of suitable size with nuts etc and making good disturbed surface, complete all as specified & directed.
Supply and laying XLPE insulated, armoured, heavy duty electric cable, with stranded aluminum conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and overall PVC sheathed 1100 Volts grade, nominal cross sectional area 6 Sqmm 2 core laid in trenches, ducts, drawn through pipes across the road/path/along poles/wall/ floors/ equipment etc including jointing and testing complete all as specified and directed.
Supply and laying XLPE insulated, armoured, heavy duty electric cable, with stranded aluminum conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or tape and overall PVC sheathed 1100 Volts grade, nominal cross sectional area 35 Sqmm 3.5 core laid in trenches, ducts, drawn through pipes across the road/path/along poles/wall/ floors/ equipment etc including jointing and testing complete all as specified and directed.
M&L for well burnt brick with sub class ‘B’ old size bricks for protection of cable complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for laying of cable etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
M&L for dry sand cushioning for UG cable in trenches including spreading levelling and hand paning and consolidating complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level exc. 250 m not exc. 500 m above the starting point complete all as specified and directed.
M&L for laying Galvanised iron tube 40 mm bore light grade (ISI marked) for cable protection to poles/under floor/under roads/alongwith walls complete including MS clamps of flat iron 25x3mm duly painted, GI nuts, bolts and washers & sealing of pipe ends with approved sealing compound, complete all as specified and directed..
Cutting/ boring of road/hard standing to a size of 30cm in width and not exc 60 cm in depth for laying of protection pipe / water line/ cable including returning, filling in, spreading, romoval of surplus soil and providing 100mm thick PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate on top, complete all as specified & directed. Note : Due care shall be taken while deciding cable route for excavation. However any damage to Signal, BSNL, MES cable water/sewage pipe or any other service while excavation will be made good by the contractor and cost of the same for jointing material & labour is deemed to be included the cost of excavation.
S&F of Intergral LED security light luminaire 90 W LED, 230 volts made up of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, luminaire, mounted on & including GI bracket made out of 50mm bore medium grade pipe of 1.70m length, bent to required shape, fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer, making connection with PVC copper conductor cable of 1.5 sqmm and taking down old unserviceable light fitting of any type/size, complete all as specified & directed.
S&F of Intergral LED security light luminaire 25 W LED, 230 volts made up of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, luminaire, mounted on & including GI bracket made out of 50mm bore medium grade pipe of 1.70m length, bent to required shape, fixed on PCC/Steel pole with 02 Nos. clamps of flat iron (40 x 6mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer, making connection with PVC copper conductor cable of 1.5 sqmm and taking down old unserviceable light fitting of any type/size, complete all as specified & directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interior dimensions in PCC 1:2:4 type B-1 RCC cover with GI frame, charcoal and common salt 15cm in layers all round the earth plate, 15mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified as per electric plate No 3 of SSR 2009 including testing after completion complete all as specified and directed.
M/S VED PAUL MAHAJAN (BID ID -3135157)
M/S SUDAGAR MAL (BID ID -3142290)
GENESIS INDIA (BID ID -3141488)
M/s ATHARAV ELETCTRICALS (BID ID -3134555)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .