| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr Quoted ₹1.5 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹1.5 Cr+₹6.6 L (4.53%)Rejected-Finance | ₹1.5 Cr+₹6.6 L (4.53%) | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 3 | L3₹1.5 Cr+₹6.7 L (4.59%)Rejected-Finance | ₹1.5 Cr+₹6.7 L (4.59%) | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 4 | L4₹1.5 Cr+₹7.0 L (4.80%)Rejected-Finance 15 MOULYA NMH LAYOUT 1ST STAGE CHIKKA BANAVARA POST BENGALURU 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹1.5 Cr+₹7.0 L (4.80%) | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| 5 | L5₹1.5 Cr+₹8.1 L (5.53%)Rejected-Finance NO 650 3RD CROSS MATHIKERE BANGALORE 560 054 | BENGALURU URBAN | KARNATAKA | 560054 | ₹1.5 Cr+₹8.1 L (5.53%) | L5 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
| Sl No | Description | Qty | Unit | A.GOVINDARAJ L1 | RAMESH BABU CO L3 | Moulya Builders L4 | devan enterprises L7 | M/S SRI BALAJI ENTERPRISES L6 | Maruthi constructions L5 | RMK PROJECTS L9 | K T ASSOCIATES L8 | SREE BUILDERS L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down defective centrifugal pump set 25 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed.
Note :- (a) The spares shall be measured and paid seperately in the relevent items given below.
(b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate.
(c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week.
(d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor.
(e) Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract.
(f) The decision of the Accepting Officer in this regard shall be final and binding. | 1 | Each Job | 4,950 ₹4,950 | 6,000 ₹6,000 | 5,850 ₹5,850 | 5,850 ₹5,850 | 5,500 ₹5,500 | 4,800 ₹4,800 Lowest | 5,885 ₹5,885 | 8,350 ₹8,350 | 5,250 ₹5,250 |
| 2.00 | Supply only Ball bearing suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC | 1 | Each | 2,050 ₹2,050 Lowest | 2,800 ₹2,800 | 2,500 ₹2,500 | 2,700 ₹2,700 | 2,350 ₹2,350 | 2,300 ₹2,300 | 2,530 ₹2,530 | 2,700 ₹2,700 | 2,250 ₹2,250 |
| 3.00 | Supply only coupling Rubber Bush suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed. | 2 | Each | 360 ₹720 Lowest | 500 ₹1,000 | 450 ₹900 | 600 ₹1,200 | 520 ₹1,040 | 400 ₹800 | 495 ₹990 | 450 ₹900 | 535 ₹1,070 |
| 4.00 | Supply only coupling bolt with nuts suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed. | 2 | Each | 320 ₹640 Lowest | 500 ₹1,000 | 420 ₹840 | 520 ₹1,040 | 470 ₹940 | 350 ₹700 | 462 ₹924 | 450 ₹900 | 485 ₹970 |
| 5.00 | Supply only shaft sleeves suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed. | 1 | Each | 640 ₹640 Lowest | 780 ₹780 | 700 ₹700 | 800 ₹800 | 800 ₹800 | 700 ₹700 | 825 ₹825 | 780 ₹780 | 780 ₹780 |
| 6.00 | Supply only Air cock grease nipple suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed. | 1 | Each | 340 ₹340 Lowest | 670 ₹670 | 600 ₹600 | 650 ₹650 | 580 ₹580 | 400 ₹400 | 523 ₹523 | 650 ₹650 | 550 ₹550 |
| 7.00 | Supply only split casing gaskets suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed. | 1 | Each | 460 ₹460 Lowest | 625 ₹625 | 580 ₹580 | 600 ₹600 | 600 ₹600 | 480 ₹480 | 605 ₹605 | 580 ₹580 | 580 ₹580 |
| 8.00 | Supply only water seal suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed. | 1 | Each | 450 ₹450 Lowest | 700 ₹700 | 650 ₹650 | 700 ₹700 | 750 ₹750 | 500 ₹500 | 770 ₹770 | 650 ₹650 | 700 ₹700 |
| 9.00 | Supply only bronze impeller suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed. | 1 | Each | 4,900 ₹4,900 | 5,800 ₹5,800 | 5,800 ₹5,800 | 6,100 ₹6,100 | 5,950 ₹5,950 | 5,500 ₹5,500 | 660 ₹660 Lowest | 5,750 ₹5,750 | 6,100 ₹6,100 |
| 10.00 | Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed. | 1 | Each | 1,300 ₹1,300 | 1,200 ₹1,200 Lowest | 1,300 ₹1,300 | 1,350 ₹1,350 | 1,250 ₹1,250 | 1,300 ₹1,300 | 1,485 ₹1,485 | 1,300 ₹1,300 | 1,350 ₹1,350 |
Tender Value
Refer Docs
EMD Value
₹2.3 L
Closing Date
18 Sept 2025, 6:00 pmClosed
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
REPAIR MAINT OF WATER SUPPLY DISTRIBUTION SYSTEM PUMP MOTOR DOZING SYSTEM UPKEEP MAINT OF ELECTRICAL SUPPLY INSTALLATION SUB STATION AND CERTAIN MISC E M WORKS AT AFTC 2 DC AREA CQAE WE AND AFS EAST WEST JALAHALLI
2025_MES_727129_1
8192/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Garrison Engineer M AF Jalahalli
₹2.3 L
11 Oct 2025
21 Aug 2025
25 Sept 2025
21 Aug 2025
18 Sept 2025
11 Sept 2025
21 Aug 2025 - 28 Aug 2025
Amount
Taking down defective centrifugal pump set 25 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling Rubber Bush suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 25 HP motor pump as per manufacturer's design complete all as specified and as directed.
M&L for suitable size of gland packing for 25 HP pump set as per manufacturer's design complete all as specified and as directed.
M&L for rewinding of induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 25 HP motor capacity.
Taking down defective centrifugal pump set 20 HP by disconnecting the pump from motor after unscrewing nuts/ bolts of coupling, foundation, suction pipe delivery pipes and shifting of pump to workshop for repair/ servicing, comprising strip opening of pump, replacement of any defective parts, carrying out necessary lathe work, re-assembling and shifting from workshop to site, re-installation at location as directed by Engr-in-Charge, testing on full load capacity at least for 8 hrs, complete all as specified and as directed. Note :- (a) The spares shall be measured and paid seperately in the relevent items given below. (b) Cost of labour for replacement of spares and transportation are deemed to be incl in the quoted rate. (c) The pumpset shall be spared for one week for repair from the date of complaint given by AGE/ JE E/M regarding breakdown. The Contractor is responsible for making alternate arrangement of pump set in case of time required more than one week. (d) In case services affected due to delay in repair of pump set, a penalty of Rs 500 per day will be levied from the contractor. (e) Please note that this penalty is exclusively other then the condition 67 of IAFW-2249 and shall be treated as interim condition of the contract. (f) The decision of the Accepting Officer in this regard shall be final and binding.
Supply only Ball bearing suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed. Make : Tata/SKF/NBC
Supply only coupling Rubber Bush suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only coupling bolt with nuts suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only shaft sleeves suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only Air cock grease nipple suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only split casing gaskets suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only water seal suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Supply only bronze impeller suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
Remetaling of shaft, turning, grinding as per the required size and polishing including provision of neck rings of impellers suitable for 20 HP motor pump as per manufacturer's design complete all as specified and as directed.
M&L for suitable size of gland packing for 20 HP pump set as per manufacturer's design complete all as specified and as directed.
M & L for servicing of starter by checking and servicing the contactor coil , over load relay coil and any other parts and replacement the burnt out wiring including any modification to pump starter panel by welding,cutting , grinding ,drilling testing the panel complete all as specified and directed for the 25/20 HP capacity pump sets Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire are deemed to be included in quoted rate.
Supply & fix in replacement of 3 Pole power contactor AC 415 V AC3 ( inductive load ) type with add on aux contact 2 NO + 2 NC 50 Hz Model No. as per existing frame suitable for 25/20 HP Pump set complete all as specified and as directed. Make : L & T / Indo Asian /Schnider
Supply and Fixing as in replacement MCCB, 4 poles 415 Volts, 100 Amps, 16 KA, 50 Hz, AC, adjustable thermal and magnetic type in the existing pump starter panel including connecting up incoming/out going cable with suitable lugs and testing complete all as specified and as directed. Make : Legrand/Indo asian/L&T
Supply & fix in replacement adjustable CT/Direct operated thermal over load relay suitable for 25/ 20 HP motor 3 phase 415v , 3 pole , with single phase protection including CTs complete all as specified and as directed. Make : L & T / Indo Asian /Schnider
S & F as in replacement ON load change over switch 4 pole 125 Amps in sheet metal enclosure complete all as specified and as directed by Engineer-in-Charge. make :- Havells /L&T/Indo Asian
Supply & fix in replacement Single phase preventer for motor in the existing panel board with new one at water supply installations complete all as specified and as directed.
Supply & fix in replacement Star Delta timer 0-30/60 sec complete all as specified and as directed.
Supply and fixing in repair of 3 phase star delta pump starter suitable for 20 HP centrifugal pump with over load relay of suitable current rating,Timer relay ,single phase preventor fixing in existing enclosure including all connected accessories complete all as specified and directed Make : L&T/Indoasian/Schenider/Havells
M&L for rewinding of induction electrical motor , 3 phase, 415 volts with suitable size of copper enameled winding wire and insulating materials incl disconnecting all electrical connections ,decoupling from pump,taking down the motor from foundation , cleaning and varnishing the stator & rotor winding, heating and drying, replacement of burnt terminals, greasing to bearings, re-assembling the motor and refixing of motor on the foundation by using new nut, bolts and washers, coupling with pump,checking alignment connecting all electrical connections,checking the vibrations, RPM and testing on full load all as directed and specified for the 20 HP motor capacity.
Taking down and relaying of existing DI water pipe lines of size 150 mm bore of any type including all fittings after removal of scading, cleaning and flushing etc complete all as specified and directed. Note: Excavation & earthwork shall be measured & paid seperately
M&L as in replacement for Ductile Iron Pipe (DI Pipes), ISI marked, Class K-7, 150 mm dia laid in trenches including jointing material such as EPDM Rubber Gasket and suitable type of grease etc complete all as specified and directed. Note :- DI fitting/special will be measured and paid separately. Note: Excavation & earthwork shall be measured & paid seperately
M & L for DI specials and fittings as per IS for spigot and socketed pipes or flanged pipe for water mains branches lines such as bends (any type radious and angle ) tapers any type (straight, bend,increasing,decresing,or double socket etc) tee piece,single branch,Y juntion, double branch, cross, including connecting pieces one end flanged and other socket or spigot and bell mouth piece suitable for rubber joint,tyton joint up to 150 mm bore and conforming to IS-9523: 2000 complete all as specified and directed
Supply and fixing in replacement Sluice valve of size 150 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed
Material and Labour for dismantling the brass splindle from 150mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Material and Labour for gland packing in leaking Sluice Valves of 150 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed .
Material & Labour as in repair for Construction of Valve pit (chamber) having inner dimensions 1200 mm x 1200 mm x 1200 mm with foundation PCC 1:4:8 type D2 using 40mm graded stone aggregate, brick work with sub class B old size built in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick rendering plaster in CM 1:4 inluding MS cover with locking arrangement all as specified and as directed. Note :- Chamber cover shall be measured and paid seperately under relevant item of Sch 'A'.
Material and Labour for Cutting DI pipes in position for insertion of new tees and socket of size 150 mm dia Complete all as specified and as directed.
Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size upto 150 mm dia, by dewatering the leakage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding,including all accessories such as tee,elbow,collar etc , and ensure no leakage with pressure test complete all as specified and as directed. Note : Pipes and mechanical collar shall be measured and paid seperately
M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of 12 mm thick complete with mechanical/detachable type arrangement as per site requirement with MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 150 mm bore complete all as specified and as directed.
Supply and fixing in replacement Sluice valve of size 100 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed
Material and Labour for dismantling the brass splindle from 100mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Material and Labour for gland packing in leaking Sluice Valves of 100 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed .
Supply and fixing in replacement butterfly valve of size 100 mm dia Cl body, both ends flanged duly drilled, ISI marked with IS-14846-2000, PN-1.6 having Stainless Steel spindle and check nut including operating wheel, fixing with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed
Cutting the existing broken / cracked CI/DI/GI/Asbestos Cement Pipe line of size upto 100 mm dia, by dewatering the leakage water from site and removing the old pipe line and addition / alteration to pipe by providing new pipe,welding,bending,grinding,including all accessories such as tee,elbow,collar etc , and ensure no leakage with pressure test complete all as specified and as directed. Note : Pipes and mechanical collar shall be measured and paid seperately
M&L for specials fittings suitable for Cast iron / ductile iron /Asbestos cement pipe made out of MS Plate of 12 mm thick complete with mechanical/detachable type arrangement as per site requirement with MS bolts and nuts of suitable size and MS sheet fabricated to required dia of pipe for prepration of collar/flange, on any pipe leak or cracks of pipe for arresting the leakage complete including rubber ring, packing rubber sheet,set of two collar rings of size 100 mm bore complete all as specified and as directed.
Material & Labour as in repair for Construction of Valve (pit chamber) having inner dimensions 900 mm x 900 mm x 900 mm with foundation PCC 1:4:8 type D2 using 40mm grade stone aggregate, brick work with sub class B old size build in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick rendering plaster in CM 1:4 inluding MS cover with locking arrangement all as specified and as directed. Note :- Chamber Covers shall be measured and paid separately under relevant item of this schedule.
Demolition of Brickwork or precast concrete block walling including wall quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and concrete articles built in cement mortar complete all as specified or directed.
M&L for Pre-cast cement concrete block masonry, type C1 (1:3:6), (using 20mm graded crushed stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:6), complete all as specified and as directed.
Material and Labour for Plain Cement Concrete (1:2:4), type B1 (using 20 mm graded stone aggregate) as in Coping, bands, benching etc including finishing the concrete surfaces even and smooth without using extra cement including necessary form work etc Complete all as specified and directed.
Material and Labour for Cutting existing DI pipes of size 80 to 100 mm dia in position for insertion of new tees and socket of size 20/25 mm dia Complete all as specified and as directed.
Material and labour for removing the submersible pump set of capacity up to 15 HP including pipes and submersible cables complete from the exisiting bore well of depth up to 200 mtr by any suitable method i.e either manual or vehicle mounted motorized system and disconnecting the pump motor to locate the faults in presence of Engr-in-Charge, transporting's to Wksp and carry out repairs, reassembling, lowering to bore well after repairs, testing and commissioning complete all as specified and directed
Material and labour for repair/overhauling of submersible pump set up to 15 HP capacity of, and any stage by replacing bushes, impeller thrust bearings, strainer, nuts and bolts, washers, pump shaft remetalling, grinding, polishing complete reassembling the pump winding the motor and testing, including painting with two coats of synthetic enamel paint after preparing the surface complete all as directed.complete all as specified and directed.
M&L flat three core PVC Insulated & PVC Sheathed Industrial Cable for Submersible Pump Motors 1100 Volt, conforming to IS 694, 6 .0 Sq mm nominal area including taking out old unserviceable cable complete all as specified and directed. Make :- Havells/Polycab/Finolex
Supply and fixing in replacement Non return valve (NRV) of size 80 mm ISI marked, gun metal body suitable for 80mm dia pipe line complete all specified and directed
Material and Labour for dismantling the brass splindle from 80mm dia bore sluice valves in various locations and reconditioning the sluice valve by replacing SS spindle, spindle nuts with brass ring, gland nuts complete all as specified and as directed.
Material and Labour for gland packing in leaking Sluice Valves of 80 mm dia size Complete including replacing/tightening the existing bolts and nuts etc. complete all as directed .
S&F in replacement foot valve cast iron of size 100 mm bore including rubber insertion, packing material, nuts, bolts, and washer with suitable new one all as specified and directed.
Supply and fix replacement of U/S leather packing suitable for foot valve 80 to 100 mm dia, suction pipe flanged connected to pumpsets including replacement of U/S nuts and bolts etc all as specified and directed
Supply and fixing in replacement Non return valve (NRV) of size 65 mm (ISI marked), gun metal body suitable for 65 mm dia pipe line complete all specified and directed
Material and labour Cleaning of valve pit chamber for sluice/gate valve of 50/80/100/150 size by removing mud/ grass/ sludge/ other waste materials from the chamber and from surroundings upto 1mtr distance, carryout petty cement repairs with cement mortar 1:4, apply one coat of white wash on plastered surfaces and one coat of synthetic paint on steel surfaces complete to make it operator friendly valve chamber complete as specified and directed. Note :- Periodicity and locations of valve chambers shall be given as per requirement by the Engineer-in-Charge.
Supply and fixing in replacement of air release valve of size 40 mm dia Cl body, ISI marked of IS 14845 of 1.6 PN including with fixing arrangement of existing 150 mm dia DI pipe line with new nuts, bolts, washers and rubber insertion/packing complete all specified and directed.
Material & Labour as in repair for Construction of Valve chamber having inner dimensions 600 mm x 600mm x 600 mm with foundation PCC 1:4:8 type D2 using 40mm grade stone aggregate, brick work with sub class B old size build in Cement mortar 1:6, PCC 1:2:4 type B1 using 20mm stone aggregate for Coping, 15 mm thick rendering in CM 1:4 inluding MS cover with locking arrangement all as specified and as directed. Note :- Chamber Covers shall be measured and paid separately under relevant item of this schedule.
Material and labour for Fabricate valve chamber covers made out of suitable size MS angle/MS plate/flat/rod, hinges, locking arrangement including painting with two coats of synthetic enamel paint over one coat of red oxide primer including removing existing unserviceable rusted cover all as directed by Engineer-in-Charge.
Material and labour for Painting with two coats of synthetic enamel paint over a coat of zink chrome on surfaces of any description, over 10cm in width or girth,not otherwise described complete all as specified and directed.
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with new GI fittings where ever replaced and required at site of site of size 50 mm bore complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with new GI fittings where ever replaced and required at site of site of size 25 mm borecomplete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with new GI fittings where ever replaced and required at site of site of size 20 mm borecomplete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
Taking down and relaying of existing serviceable GI tubing / connection in new or old positions including cleaning, cutting, threading all as directed, along with new GI fittings where ever replaced and required at site of site of size 15 mm borecomplete all as specified directed.
Supply & Fix as in replacement of GI tubing medium grade of size 100 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply & Fix as in replacement of GI tubing medium grade of size 80 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply & Fix as in replacement of GI tubing medium grade of size 50 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
Supply & Fix as in replacement of GI tubing medium grade of size 40 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
Note :- (a) In case of laying of CI/GI/DI pipe line is to be executed in civil area, it will be the responsibility of the contractor to obtain necessary permission for cutting of road & berm from BWSSB.
(b) For this purpose any charges/ amount to be paid online to BWSSB, shall deemed to be included in unit quoted rate by the bidder and nothing extra shall be admissible on this account.
(c) The T&P like JCB, Drill Machine, Moveable Generator etc required for cutting of road shall be arranged by the contractor & no extra cost shall be paid by MES for the same.
(d) After execution of work, the contractor shall make good disturbed portion of road with bitumen or PCC complete as directed by Engineer-in-Charge. Cost of the same is deemed to be included in unit quoted rate.
Material and labour for Making arrangement to flush out the existing pipe line of any type of size 63 to 150 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Material and labour for Making arrangement to flush out the existing pipe line of any type upto 50 mm bore and upto 100m length, applying 4.5 N/sqmm pressure kg/sq cm pressure to remove scalings/ sludges/ other blocking materials to make smooth flow of water including testing all as specified and directed.
Note for item 80 & 81 :- (i) The Contractor is deemed to arrange necessary tools and equipments, removing or alteration of fittings from existing pipe lines, arragement of plugging devices, etc to build up specified pressure required to wash out the pipes. This shall be inclusive in quoted rate. (ii) Excavation and earth work required shall be measured and paid seperately. (iii) The flushing out shall be carried out with fresh filled water of well only duly chlorinated with specified sodium hypochlorite solution to disinfect the pipe lines from all pathogens and Coliform organisms.This shall be inclusive in quoted rate.
S&F in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 50mm complete all as specified and directed.
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 40 mm complete all as specified and directed
Material and labour for Attending day to day water supply service related complaints like choking of rising main pipes of buildings, blockage in control valves/ float valves/ pipe fittings, etc, applying necessary engineering efforts like dismantle of pipes and fittings to clean and remove blocking objects, descaling of pipes, re-fixing of pipes on wall, etc to restore the proper flow of water to service tanks all as specified and directed by Engineer-in-Charge.
Note :- (a) The contractor has to attend above mentioned job in any location of entire CQAE (WE) Area
(b) The service tanks are positioned on roof top of multi storied buildings upto three storey. Contractor is responsible to ensure that the labour employed should be equipped with safety items like industrial helmet, safety belt, extensible ladder of 40 feet length, plumbing and cuttings tools, etc.
(c) The cost of rethreading of GI pipes of 25mm dia and adding of new GI nipple of suitable length after rethreading is deemed to be included in the quoted rate.
(d) Due to shortage of water in the station, the repair work and testing required under this item need to be carried out during water supply distribution hours i.e. 5:30 AM to 7:30 AM. Nothing extra shall be permitted in this regard.
(e) The cost of repair to the damages of cemented surfaces/ external finishes/ metal clamps of rising pipes are also deemed to be included in the quoted rate.
(f) In case of any delay in attending the complaint more than 6 hrs after handing over routine/urgent complaints, the contractor shall be liable to pay the penalty as described in penalty clause given here as under.
(g) If the delay is more then 06 hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs 100/- per job shall be deducted from the dues of the contractor. Please note that this penalty is exclusively other then the condition 67 of IAFW - 2249 and shall be treated as interim condition of the contract and shall be enforce above as and when delay in individual job is noticed and no claim whatsoever on this account shall be entertained by the Deptt.
(h) The decision of the Accepting Officer in this regard shall be final and binding.
Supply and fixing in repair 20 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair 25 mm dia Chlorinated PVC (CPVC) Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair Chlorinated PVC Gate Valve of size 20 mm dia, ISI marked complete all as specified and as directed.
Supply and fixing in repair Chlorinated PVC Gate Valve of size 25 mm dia, ISI marked complete all as specified and as directed.
Supply and fix of PVC water tank 500 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I ,complete all as directed incl disconnecting existing old tank of any description and any capacity complete all as specified and directed
Supply and fix in replacements lids for polythylene water storage tanks, threaded or hinged type as per existing incl PTMT nuts/binding wire complete all as specified and directed suitable for upto 500 Ltrs cap of tanks.
Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 20 mm complete all as specified and directed
M&L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in cement mortor 1 : 4, complete, in walls all as specified and directed by Engr-in-Charge.
Supply and fixing Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, hinges and handles etc. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and directed.
Supply and fix of PVC water tank 1000 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I ,complete all as directed incl disconnecting existing old tank of any description and any capacity complete all as specified and directed
Supply and fix in replacement lids for polythylene water storage tanks, threaded or hinged type as per existing incl PTMT nuts/binding wire complete all as specified and directed by Engineer-in-Charge suitable for 1000 Ltrs cap of tanks.
Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 25 mm complete all as specified and directed
Supply and fix PVC water tank 2000 Ltrs Capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as directed incl disconnecting existing old tank of any description and capacity complete all as specified and directed
Supply and fix in replacement PVC Ball valve ISI marked high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 40mm complete all as specified and directed
Supply & Fix as in replacement of GI tubing medium grade of size 25 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm complete all as specified and directed.
Supply & Fix as in replacement of GI tubing medium grade of size 20 mm bore with all fittings on wall/ trenches complete including cutting and threading all as required at site complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 20 mm complete all as specified and directed.
Supply & Fix as in replacement of GI tubing medium grade of size 15 mm bore with all fittings on wall/ trenches complete including cutting and thereading all as required at site complete all as specified directed. Note: Excavation & earthwork shall be measured & paid seperately
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of size 15 mm complete all as specified and directed.
S & F in replacement Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe fixed of size 15 mm for brass ferrule chromium plated fency type and fixed complete all as specified and directed.
Cleaning of service tanks of the capacity as mentioned below on roof top of bldgs upto three storey after disconnection from inlet and outlet pipe, removing of float valve of service tank and keep aside safely for reuse drain out water through drain plug, cleaning thoroughly to remove all scales and dirt by brushing internal surface, cleaning properly inside with soda wash, flushing out with fresh water, re-positioning of tank at same place, re-connecting inlet and outlet pipes, closing of drain plug, re-installation of float valve duly cleaned, writing/ labelling the record of cleaning carried out with white bold letter such as "TANK CLEANED ON"--------- (month and year), including removing creepers, vegitation and roots of plants, trees branches on or surrounding of service tank complete all as directed. Note:-(i) Unit rate quoted is deemed to be included for testing of water supply in tank both inlet and outlet flow during next supply hours early in the morning or late in evening. (ii) Contractor shall maintain a pucca bound register for cleaning carried out with date and obtain users signature and remarks if any and this register to be submitted alongwith RAR. (iii) Contractor is liable to rectify any damages to the external finishes of the bldg occured during the cleaning process, i.e. scrubbing and touch up with external paints as existing specifications. Unit rate quoted is deemed too be included the cost of the same. (iv) All sort of petty T&P items such as ladder, safety equipment, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
(a) For PVC tank exceeding 200 litters and not exceeding 500 ltrs
(b) For PVC tank exceeding 501 litters and not exceeding 1000 ltrs
(c) For PVC tank exceeding 1001 litters and not exceeding 2000 ltrs
Supply and fix Nipple suitable for HDPE water tank of size 20 mm complete all as specified and as directed.
Supply and fix Nipple suitable for HDPE water tank of size 25 mm complete all as specified and as directed.
Supply and fix Nipple suitable for HDPE water tank of size 40 mm complete all as specified and as directed.
Supply, install, testing and commissioning of Chemical Dosing system having top dia 540mm x bottom dia 480mm x height 575 mm, net capacity 95 - 100 Ltr consisting of (i) water inlet line (ii) Dosing pump inlet arrangement (iii) Drain (iv) Overflow (v) Level Gauge (vi) inspection port (vii) Agitator 120 watt 800 - 900 RPM Single Phase flange mounted motor with plastic shaft and impeller (ix) provision of mounting Pump on Lid/wall along with dosing Injector of the following specification. Adjustble dosing pump max pressure 5kg/cm square & max flow rate 0 - 50 ltr / hr including all accessories such as Lead tubing, Connecting Ferrules, check valves, non return valve all as directed. Power input 230V, 50 Hz, 40 SPM 1/30 fractional Horsepower, etc complete all as specified and directed. Make: - Model No. VST 1011 of Ravi Enterprise or equivalent as per E-in-Cs approved make. Note: Unit quote rate shall be inclusive of taking down of old unserviceable plant and depositing same to MES store yard .
Supply Only Chlorine test kit with coloured sample Complete with all testing fitments and OT - solution in Rexene finished box Complete all as specified and as directed
Supply of calcium based high strength chlorination chemical for water in granular form chlorine concentration level having 65%-70% chlorine content packed in 45 Kg capacity in factory sealed HDPE Container superior quality suitable for treatment of drinking water complete all as specified and directed. Note:The material should be delivered at watersupply installation as per direction of AGE E/M on required basis during the contract period.
Chemical and physical analysis of water confirming to IS3025 - 58 (2006) second revision of various locations at CQAE from any lab authorised by central/state govt for chemical analysis. The following test should be carried out :- (a) Bacteriological Quality of water (ref Table 6, Clause 4.1.1, IS 105000 : 2012 second revision) (b) General Parameters Concerning Substances of water (ref Table 2, Clause 4.0, IS 10500 : 2012 second revision) (c) Organoleptic and Physical Parameters of water (ref Table 1, Clause 4.0, IS 10500 : 2012 second revision) Note : Contractor shall collect the water samples and submit the test results to Engr-in-Charge all as specified and directed.
Supply ,Install, testing and commissioning in replacement of Smart control panel for dosing system with 3phase input supply and output capacity of minimum 6A and upgradable to 16A, Equipped with 20x4 Character LCD to display real time phase wise voltage. 5 mm LED Indication for fault detection including Under Voltage (380 Vac), Over load (440 Vac), Phase failure, Over Load. Weather proof IP54 enclosure indoor type complete all as specified and directed.
M&L for dewatering & Cleaning of RCC Over Head Tanks of the following capacities by involving of the followings 09 (NINE) stage of cleaning process complete all as specified and directed (i) De-watering by high pressure submersible pump complete (ii) Removal of sludge from RCC Over Head Tanks (iii) Cleaning of walls, floors, ceiling etc by high pressure jet pump 80-180 bar pressure l complete (iv) Removing dirt and sludge by vacuum pump (v) Anti- Bacterial Treatment to inside of tank which effective against all pathogens all complete. (vi) Sterilization of the tank atomosphere by UV radiation inside of the tank. (vii) Applying one coat of white wash to internal surfaces. (viii) Replace nylon net for vent pipes & man hole covers (ix) Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc
Note for item No 127 :- The Bidder shall take into consideration for following points while quoting his rate for this item and the unit rate is deemed to be included for :- (i) The contractor shall provide dewatering pump of suitable capacity and mobile generator for operation of dewatering by high pressure submersible pump (or) Diesel driven high pressure pump and the rate quoted is inclusive of rent/hiring charge complete. (ii) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (iii) Material removed from the tank shall be disposed off at out side MD land. (iv) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job within the given period only. or otherwise penalty shall be imposed @ Rs 500/- per day. (v) All safety with gadgets like safety Belts, special safety ladder, Helmets, Heavy Duty Gum Boots, Gloves, Safety Goggles, Masks, Aprons, etc. for complete security the safe operations. Storage and Cleaning equipment’s like Scrubbers/Wipers, Storage drums, Sludge Collectors and Cisterns, etc. must be integral part of system.
(a) water tank of capacity 228000 Ltr of approx 32 Mtr Height
M&L for dewatering & Cleaning of RCC UG sumps of the following capacities by involving of the followings 09 (Nine) stage of cleaning process complete all as specified and directed (i) De-watering by high pressure submersible pump complete (ii) Removal of sludge from sump (iii) Cleaning of walls, floors, ceiling etc by high pressure jet pump 80-180 bar pressure complete (iv) Removing dirt and sludge by vaccum pump. (v) Anti- Bacterial Treatment to inside of tank which is effective against all pathogens complete. (vi) Sterilization of the tank atomosphere by UV radiation inside of the tank. (vii) Applying one coat of white wash internal surfaces. (viii) Replace nylon net for vent pipes & man hole cover (ix) Writing letter in bold with white paint on black colour back ground such as sump number, capacity, cleaned on Date & Due on Date etc
Note for item No 130 :- The Bidder shall take into consideration for following points while quoting his rate for this item and the unit rate is deemed to be included for :- (i) The contractor shall be provide dewatering pump of suitable capacity and mobile generator for operation of dewatering by high pressure submersible pump (or) Diesel driven high pressure pump and the rate quoted is inclusive of rent/hiring charge complete. (ii) Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level. Useful material shall be stacked. (iii) Material removed from the tank shall be disposed off at out side MD land. (iv) Tank shall be made available for cleaning for a period of 8 hours only and contractor has to arrange sufficient labour/ T&P to complete the job within the given period only. or otherwise penality shall be imposed @ Rs 500/- per day. (v) All safety with gadgets like safety Belts, special safety ladder, Helmets, Heavy Duty Gum Boots, Gloves, Safety Goggles, Masks, Aprons, etc. for complete security the safe operations. Storage and Cleaning equipment’s like Scrubbers/Wipers, Storage drums, Sludge Collectors and Cisterns, etc. must be integral part of system.
(a) Underground sump of 15000 gallon capacity.
(b) Underground sump of 10000 gallon capacity.
(c) SWT sump of 15000 gallon capacity.
(d) SWT sump of 10000 gallon capacity.
M/L for Fixing in repairs Water Level Indicator for UG sump consisting of float ball, nylon rope, Scale for water level indication made out of MS frame with pulley and indicating pointer all as specified and directed by Engr-in-Charge.
Supply and fixing in repair 25 mm dia Unplasticiced PVC Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair 20 mm dia Unplasticiced PVC Pipes of pressure rating 10kgf/cm2 including fittings like socket / union / Tee / Reducer / Nipple etc complete fixed to wall/ceilings/ in floors etc, complete all as specified and directed.
Supply and fixing in repair UPVC Gate Valve of size 25 mm dia , ISI marked complete all as specified and as directed.
Supply and fixing in repair UPVC Gate Valve of size 20 mm dia, ISI marked complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level and laying of pipelines etc in soft/loose soil, complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified and directed.
Removing surplus excavated material (soil) not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point, complete all as specified and directed.
Material and labour for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983, complete all as specified and directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc. as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is then gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness shall be considered for payment.
Material and labour for well burnt bricks ‘B’ class as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench, complete all as specified and directed.
Material and labour for Cutting existing road/PCC/Drain for laying of GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, 800 mm wide including making good existing surface with 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate, complete all as specified and directed. Note :- The tenderer shall take into consideration for following points while quoting rate for this item and the unit rate is deemed to be inclusive for :- (i) Earth work and excavation in any type of soil (ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick ,complete all as specified and as directed. (iii) Removing excavated material out side MD land. (iv) Laying of any type/any bore of pipe in trenches including taking down existing unserviceable pipe. Supply of pipe shall be measured and paid separately (v) 150 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in road to make good existing disturbed surfaces.
Supply only of GI pipe light grade for cable protection of size 50mm bore with fittings, complete all as specified and directed.
Material and labour for Boring of holes under road, pavement hard standings by trenchless technology using ultra sound technique and necessary machine including supply of HDPE pipes upto 100 mm dia suitable for 0.4 Mpa working pressure, complete all as specified and directed.
Material and labour in repair for 3 ½ core 95 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for 3 ½ core 70 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 3.50 core 70 Sqmm to 95 Sqmm, complete all as specified and directed.
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be minimum 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF > 0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggreate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed and comprising of the following :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 01 No(O/G). (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 01 No(O/G). (d) MCB SPN of 415 V of capacity 40 Amps 10 KA - 02 Nos (O/G) (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (g) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thermoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be above 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF > 0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 300 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggreate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 25 KA - 01 No. (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (f) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Taking down and errecting steel swaged tubular pole 8.5/9 mtr long, bracket for fixing street light and refixing the same including necessary PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) in foundation size of 50 x 50 x 45 cm and coping with 1:2:4, type B1 (using 20 mm graded stone aggregate) complete all as specified and directed.
Material and labour for applying one coat of cement base paint to RCC pole 7/9.0 metre long after scraping / brushing and cleaning the pole and street light bracket to be painted with one coat of Aluminium paint. Cement base paint shall be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white with synthetic enamel paint (30 Cms Each) Pole Nos shall be written on pole with black paint in yellow circle of 150mm dia, complete, all as specified and directed.
Material and labour for Painting of steel tubular pole 7/9.0 metre long, by applying one coat of aluminium paint after scraping / brushing and cleaning the rust on pole and street light bracket. Aluminium painting will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white with synthetic enamel paint (30 Cms Each). Pole Nos shall be written on pole with black paint in yellow circle of 150mm dia, complete all as specified and directed.
M &L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in copping to pole including necessary form work slightly rounding or squaring, complete all as specified and as directed.
M & L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass concrete for poles etc, complete all as specified and as directed
Supply & Erecting Mild steel tubular swaged pole 9 meter long 410, SP-31 complete with cast iron base plate, bracket, finial taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer and painting with black up to 1.5 meter from top of PCC 1:3:6 using 20 mm graded stone aggregate coping white colour paint as in strips of equal width with marking pole numbers by using one coat of synthetic enamel paint including necessary PCC 1:4:8 with 40 mm graded stone aggregate as in foundation and coping as per TD drawing including dismantling of old damaged pole complete all as specified and as directed.Note (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer. The rate for above items shall be deemed to be inclusive in the quoted rate.
Supply and fix in repair bracket for street light fitting made out of 40 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers and fixing to the pole etc complete all as specified and directed.
Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 300x200x100mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified and directed.
Supply and fixing in repair new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of 60 to 72 watt complete all as specified and directed. Make:Halonix/Philips/CG/Bajaj
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 4 Sqmm with multistrand aluminium conductor including taking down of old one complete all as specified and directed. Make: Plaza/Polycab/ Finolex/Havells
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 20 KW 3 phase 64 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor etc complete with following:- (i) Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. (ii) Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. (iii) The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1using 20 mm graded aggregate for grouting of base including taking down old unserviceable panel etc complete. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity. The panel should have three operation mode :- 1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switched as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The GSM controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS, complete all as specified and directed including the following subcomponent, supply and fixing features :-
(a) TPN MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No. (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, C&S Havells) (b) Supply Resign cast CT'S - set of 3 (c) GSM based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 32 Amps -02 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 06 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 Amp rating with brass contacts for INPUT/ and 63 Amp for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 Sqmm & power wiring 10 Sqmm flexible. Make- Tricolite/ Kewintech/HPL
Supplying, errecting and fixing as in repair GI tubular swaged welded pole of over all height 6.0 m long for all in one solar light complete with cast iron base plate, finial tapper plug cap, bolt, nut and washer etc., complete all as specified and directed . Note (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole copping shall be painted with 2 coats of black and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular shall be painted with 2 coats of aluminium paint over a coat of red oxide primer the rate for above items shall be deemed to be inclusive in the quoted rate.
Supply and fix in repair weather proof PVC junction box approved by CPRI for street light control box made out of not less than 2mm thick and size 250mm x 200 mm x 105mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No. panel mounted connector 4 pole 32A-1 No, MCB SP 6A 10KA-01No, including connecting up with the electrical connections and fixing with clamps etc complete and all as specified and directed.
Supply and fixing in repair new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device of 90 watt complete all as specified and directed. Make:Halonix/Philips/CG/Bajaj
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/Havells
Supply and fixing in repair Round spherical garden lighting, post top lantern having B22 holder suitable for LED bulb 10 watt, 220 volt,50HZ,IP65 including suitable of GI tubing ,length as per site requirement on gate pillars/ garden lights for fixing the lamp, wiring with 1.5 Sqmm PVC insulated stranded copper conductor including PCC work for fixing, of light fitting complete all as specified and directed.Make: Philips/ Havells/Bajaj/CG.
Suply and fix in repairs LED decorative post top lantern fitting 40W, 230V AC with IP 65 protection and resistant to impact and corrosion with necessary electrical connection complete all as specified as directed. Make: Bajaj / Philips/Halonix/ CG
S & F aluminum lugs suitable for aluminum cable of size 10 to 35 Sqmm complete all as specified and directed
S & F aluminum lugs suitable for aluminum cable of size 50 to 95 Sqmm complete all as specified and directed
S & F aluminum lugs suitable for aluminum cable of size 120 to 185 Sqmm complete all as specified and directed
S & F copper lugs suitable for copper cable of size 240 to 300 Sqmm complete all as specified and directed
Material and labour in repair for 3 ½ core 35 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for 3 ½ core 25 Sqmm XLPE insulated heavy duty electric cable with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheathed laying in trenches/cable ducts, fixed to wall/pole, complete all as specified and directed. Make : Havells, Polycab, RPG Asian
Material and labour in repair for making straight through joint with suitable jointing kit consisting of water proof adhesives for UG cable of size 3.50 core 25 Sqmm to 35 Sqmm, complete all as specified and directed.
Supply and fix in repair LED flood light fitting 200 W integral type light fixture, cast aluminum body, reflector, drivers, LEDs and accessories with system wattage 200W etc complete all as specified and directed. Make : Bajaj/Philips/CG/Halonix.
Supply and fixing in repair LED flood light 150 watt made up of die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection and system efficiency ≥ 125 LPW with option for 3000K 10 KV SPD corrosion resistant complete with driver and lamp Protection including street light fitting bracket nuts, bolts, washers complete, all as specified and directed. Make:Halonix/Philips/CG/Bajaj
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 10 Sqmm with multistrand aluminium conductor including taking down of old one complete all as directed and specified. Make: Plaza/Polycab/ Finolex/ Havells
Supply, installation, testing and commissioning of smart street light control system using GSM/Lux based technology having 12 KW 3 phase 32 Amp load capacity per phase and can be operated by IVRS/SMS/lux based infrared sensor. Nature switch operation should be based on natural light lux level. Require illuminnance level for switching on is ≤ 60 lux and for switching off ≥ 10 lux. The smart unit should have 4 timers that can be set via SMS. Surge protection device (SPD) should provide protection agaist indirect lightning & switching surges. It should conform to IEC61643-11 and should have 40 KA capacity. The sensor & SPD along with suitable power contactors and incoming-outgoing MCCB/MCBs should be enclosed in a enclosure made of rust proof, electric shock proof , metal weather proof conforming to IP65 with angle iron frame of suitable size 04 Nos legs 600 mm long , PCC 1:2:4 type B1 for grouting of base including taking down unserviceable panel etc complete. The scope of work also comprising the following :- The GPRS shall have seven segment display to show voltage, current, network and street light status , it should also have indicator for showing supply status , timer , overload or high low voltage. It should also able to measure voltage, current and automatic set street light overload current. Unit have facility to call back to registered number for power on/off and if any fault occurs at site.in SMS it should also monitor power/on/off time light on off time, Ampere, voltage, unit mode, network percentage date and mobile number who called device number. The device should also have battery backup with minimum 24 hours backup capacity.The panel should have three operation mode :-1. GSM mode -in this mode light should be switched as per GSM controller's preset time by user by sms , 4 clock base timer facility should be availble 2. Nature switch based-in this mode light will be switches as per nature light lux level 3. Bypass mode -in this mode light will switched on directly for testing purpose and emeregncy switching .In GSM controller there should be facility to register 4 user by sms/call and alerts will be sent on all registered number and also call back on power on/off and faults on first registered number.The Gsm controller should also compatible for cloud based data transmission for interfacing with web for future use, Password protection for Accessing the control of device via SMS/IVRS complete all as specified and directed.
(a) MCCB 100 Amps capacity, 10 KA, 415 Volts -01 No (Incoming) with separate SPD of 40 KA capacity. (Make of MCCB- L & T, BCH, Havells) (b) Supply Resign cast CT'S - set of 3 (c) Gsm based smart street light controller. (d) Lux based sensor to operate external as per light intensity. (e) Line Contactor, AC 3 duty, 3 phase, 415 volts. 50 Hz , 25 Amps -03 Nos (make - L & T, BCH, Havells) (f) MCB SP 32 Amps- 03 Nos (make -L & T, BCH, Havells) (g) Terminal block suitable for 100 A rating with brass contacts for INPUT/ and 63 A for OUTPUT termination. (h) GSM/Timer/Bypass Mode switch. (j) Panel wiring for control circuit with copper flexible 1.5 sqmm & power wiring 10 sqmm flexible. Make- Tricolite/ Kewintech/HPL
Point wiring with 1.5 Sqmm (nominal area) PVC insulated and unsheathed single core FRLSH cable 1100 volts grade with stranded copper conductor in and including rigid steel ERW concealed conduit and conduit accessories in wall, floors and ceiling including PTFE(Teailon) type sealing of joint along with continuous earth wire 1.5 Sqmm PVC insulated and unsheathed single core FRLSH cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including suitable standard accessories complete for one No. flame proof light point/ one fan point /one exhaust fan controlled by one way flame proof switch all as specified and directed. Make of Cable : Plaza/ Polycab/ Havells
Supply and fix Switch flame proof rotary type with termination box in LM6,16 A, single pole 250V all as specified and directed.Make : Sudhir/Bajaj/Baliga
Material and labour for Flame proof junction box in LM6 upto 1" and upto 4 way complete all as specified and directed.Make- Sudhir/ Shyam Switchgear/Baliga
Supply and fixing flame proof exhaust fan of sweep size 300 mm,single phase,230V including louvers and blades complete all as specified and directed. Make- Sudhir/ Shyam Switchgear/Baliga
S & F LED tube light fitting flameproof type suitable for single tube 20 W LED integral built in control box made of aluminium alloy LM6 , IP65 with all accessories, complete all as specified and as directed. Make- Sudhir/ Shyam Switchgear/Baliga
S&F fix flame proof cast iron enclosure distribution board 415 volts, 6 way, SPN and MCB suitable for explosive atmosphere with explosive including necessary panel board for required connection from busbar to different outgoing and including making good to the disturbed surfaces of walls, floors etc, complete with following incoming and outgoing controls all as specified and directed:- (i) Incoming:- MCB, 2 Pole 32 Amp -01 Nos. (ii) Outgoing:- MCB Single Pole 6-32 Amp - 04 Nos. with complete internal bus bar & wiring up to terminals Make:- Shyaam Switch Gear Product Cat No SSPL/MCDB/186 or equivalent in Baliga / Sudhir
Dismantling structural steel work incl doors, gates but excluding framed trusses etc complete all as specified and directed.
S&F in framed work as in doors or gates of angle,tubes or other section with gusset plates, rails, Plain sheet braces,guard bar etc., complete, to be prepared for hanging or sliding with and including hinges or steel hanging door fittings (exclusive of steel sheeting or other covering) and hanging; also fastening and fixing Fe 410 -W (Gde- E- 250) quality-A complete all as specified.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws & included dismantling of any type of sheets in roof coverings complete all as specified & directed
S & F MS Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.11611979 grade St.-240 complete all as specified & directed
M & L for 100 mm thick PCC 1:2:4 type B-2 (using 40 mm graded crushed stone agg) as in PCC in Hard standing etc. with , spike rolling ,or making impression of expanded metal, while the concrete is green complete all as specified including Demolition of Concrete (un reinforced) of any description and in any position not otherwise specifically provided.
Forming Construction joints 30 mm deep x 10 mm wide filled with epoxy sealing compound grade 'A' all as specified and directed.
M&L for Cement concrete 1:3:6 type C2 (using 40 mm graded stone agg) as in foundation filling and for mass concrete and all as specified and directed including Demolition of Concrete (un reinforced) of any description and in any position not otherwise specifically provided. .
M&L Pre-Cast cement concrete block masonry PCC 1:3:6 type C1 (20 mm graded agg) with solid blocks exc. 10cm in width and set in cement mortar 1:6 including demolition of brick work / stone masonry/PCC block built in cement mortar of any description as specified and directed.
M & L rendering 15 mm thick CM 1:4 on brick surfaces finished even and smooth with out using extra cement as specified and directed.
M&L Preparation of newly plastered surfaces of walls and applying two coats cement base paint on walls over a coat of alkali resistant primer all as specified and directed.
M&L for cement plaster rendering 15mm thick on fair faces of brick/concrete surfaces with two coats i.e. (10mm thick backing coat in CM 1:6 and 5mm thick finishing coat in CM 1:4) and mixed with WPC, finished even and smooth without using extra cement (WPC to be measured and paid separately) and including taking down old cement plaster on brick or stone walls, or concrete walls etc., hacking for key, scrubbing down with water, etc., including removal of rubbish off the premises complete all as per specified and directed.
Supply only water proofing Liquid of approved make ISI marked all as specified and directed.
M&L for machine pressed pre polished pre-cast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over sand cushion with grey cement and no pigment and side kerb concrete, incl removal debris and necessary demolition all as specified and directed by Engr-in-Charge.
M & L for Sand filling under floors or in foundations including watering and consolidation and all as specified and directed.
Dismantling posts or struts (wood, steel, or RCC) any section, any length not exc 5m including taking out embedded portion in concrete, brick work, masonry etc and all as specified and directed and incl necessary excavation and earthwork for new post holes all as specified and directed.
M&L for Cement concrete 1:3:6 type C2 (using 40 mm graded stone agg) as in foundation filling and for mass concrete complete all as specified and directed
S & F MS angle iron hand rails, fencing posts, flat iron including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F in repairs MS round bars 10 mm dia and over Fe 290 (Gde - E-165) cut to length bent to shape required including cranking, bending spirally, hooping for columns, hooking ends all as specified and directed.
S &F in repairs Mild steel screw bolts (machine made) dia of neck 16 to 20mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long all as specified and directed.
Supply only of chain link fencing MS galvanised sqaure wire mesh of any size, dia of wire 4mm including line wires, to any type of standard rails, straining bolts, etc all as specified and directed.
Fixing only in repairs chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc inlcuding provision of binding wire and dismantling fencing wire mesh of any type etc all as specified and directed.
S&F in repair galvanised two strand steel barbed wire 2.24 mm dia barbed wire with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised MS wire staples or steel pins etc , complete all as specified and directed. (each line wire to be measured)
Restraining and resecuring barbed wire including making good staples etc (each line wire to be measured), complete all as specified and directed.
M & L mild steel TMT bar 10mm dia and over cut to length bent to shape as required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S complete all as specified and as directed.
Demolition of stone boulder masonry, built in cement mortar or cement lime mortar incl all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L in walling of random rubble, uncoursed, Bangalore type masonry, well bonded bedded and solidly hearted, built in CM 1:6, extra over stone walling for hammer dressing (40mm) to face stones and dressing of face beds and joints as specified, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4, complete all as specified and directed.
Fixing only(except stone) of random rubble, uncoursed, Bangalore type masonry well bonded, bedded, solidly hearted built in CM 1:6, extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4 complete all as specified and directed. (Note:- stone demolished under above item shall be re-used)
Material and labour for keyed pointing in cement mortar 1:4 to random or polygonal rubble masonry including racking out joints / points in cement mortar to squared rubble masonary coursed or un coursed etc complete, all as specified and directed.
M&L for broken stone boulders hard core of guage n.exc 63mm deposited spread and level laid in layers n.exc 15cm thick, watered and rammed to a true surface in repairs complete all as specified and directed.
M&L in repairs 300x300x25mm thick prepolished cement concrete chequered tiles jointed in neat cement slurry and pointed in white or coloured cement to match the floor and including 20mm thick screed bed in CM 1:4 and incl removal of old debris and including necessary demolition etc complete all as specified and directed
M&L PCC (1:4:8) type D2 using 40mm graded aggregate 75mm thick as in sub base of floor finished even and rough to receive top layer and all as specified and directed including Demolition of Concrete (un reinforced) of any description and in any position not otherwise specifically provided.
M & L for precast reinforced cement concrete (1:2:4) type B1 (using 20mm graded stone aggregate) setting in CM 1:6 work for landings, cover slabs, manholes, chajjas, water troughs, manger shleves and similar articles with plain faces and demolition of old reinforced cement concrete of any description and in any position and complete all as specified and directed.
M&L Cleaning and Removing silt, grit , mud and other materials from covered drain in foul condition including removing materials from the site to outside MD land including necessary removing cover slabs and replacing after cleaning area including making good any damages complete all as specified and as directed.
Note for item No 224 :- The unit rate is deemed to be included for Removing of accumulated earth at sides of drain of any width and depth up to 30 cm. cleaning/cutting the grass around 1 m from drain (both sides) and removing the grass waste to outside MD land. Cutting and filling shall be cleared of shrubs, vegetation, grass bush, weed, trees and sapling not exceeding 30 cm in girth, measured at a height of two metre above ground level . Cutting the grass/felling of trees shall include digging out roots up to 60 cm below the ground level or 14 cm below the formation level, whichever is lower. All holes and hollows formed in the ground digging out of roots shall be carefully filled up with moorum/red bajri well rammed and levelled.
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenches bore of pipe 75 mm with PVC clamps and saddles including taking down existing pipes and Dismantling of old unserviceable cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed
S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenches bore of pipe 110 mm with PVC clamps and saddles including taking down existing pipes and Dismantling of old unserviceablecast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed
S & F in repairs PVC (SWR) bends of any radius with access door bore of pipe 75 mm complete all as specified and as directed.
S & F in repairs PVC (SWR) bends of any radius with access door bore of pipe 110 mm complete all as specified and as directed.
S&F in repairs Stop Valve standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-90gms) complete all as specified and as directed.
S & F in repair bib tap standard of PTMT any colour screwed for iron pipe and fixed,15 mm bore (minimum weight 90gms) complete all as specified and as directed.
S & F in repairs PVC low level flushing cistern 10 Lit capacity including necessary brackets incl connecting flush pipe etc and making good the disturbed surfaces complete all as specified and as directed.
S&F in repairs Wash basin vitreous china (flat back or angle back type) size 580x400mm including taps waste chain and plug and porceline stopper but brackets including cutting for and pinning in ends of brackets or erecting stand with waste pipe, complete all as specified and directed.
S & F in repair waste coupling 32 mm dia of PTMT (half or full threaded) minimum weight 45 gram complete all as specified and as directed.
S & F in repairs PVC connection pipe 15 mm dia, 600 mm long with check nut and bolt with washer complete all as specified and as directed.
S&F in repairs PVC waste pipe 32/40mm bore for WHB, Urinal & Sink complete all as specified and as directed.
S&F in repairs grating doom 125mm dia with waste hole of Chromium plated (Min wt 40 gms) complete all as specified and as directed.
S & F in repair vitreous china squatting pan 'Orissa pattern ' size 580 x 440mm white with integral foot rests incl connecting to 'P' or 'S' trap and to flush pipe anti syphonage pipe etc compete including provn of lime concerte bedding and making good to floor complete all as specified and as directed.
S&F in repairs pillar tap standard of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-110gms) complete all as specified and directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises & M&L for ceramic coloured tiles of size 350mmx250mm/ 300mm X 450mmx7 to 8 mm thick, on vertical surfaces, set and jointed in neat cement slurry and pointed in coloured / white cement to match the tiles inc rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces as in backing coat to receive wall tiles etc complete all as specified and directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises & M&L for joint free non skid coloured ceramic tiles 7 to 8 mm thick area of each tile not exc 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15 mm thick screed bed in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
Taking down chowkhat or frame (wooden/steel/aluminium) not exceeding 1.5 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
S&F Steel windows with side hung shutters including projecting type hinges, frame with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F 4 mm thick sheet glass ordinary quality and glazing complete in square n exc 0.50sqm in each pane complete all as specified and directed.
S&F frosted glass 4.0mm thick, pin head type n exc 0.5 Sq.m in each pane and fixed. complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube complete all as specified and directed.
S&F Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified and directed.
S&F Butt hinges 75 mm long medium weight cold rolled stainless steel complete all as specified and as directed.
Supply and fixing 150 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed.
Supply and fixing aluminium handles cast type anodized 150 mm long complete all as specified and as directed.
S&F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed.
M&L for Preparation of old painted wooden surface of any description and applying one coat of synthetic enamel paint, not otherwise described over 10 cm width or girth, complete all as specified and directed.
Supply and fixing Anodized aluminium size 605 x 605 mm snap grid frame work for false ceiling as per manufacturer instructions, with suitable size GI wire Hangers (up to 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long and 6mm thick Non asbestos fibre cement building boards, fixed to sheet suitably placed in false ceiling grid made of Aluminium/G.I./ M.S.as per specification and drawing and including dismantling old unservicable ceiling board & frame of any type and description, complete all as specified and directed.
Taking down chowkhat or frame (wooden/steel) exceeding 1.50 Sqm not exceeding 4.0 Sqm each with shutter (with out taking off shutters from the frame) all as specified and as directed.
Taking down shutters of any description exc 1.0 Sq.m and n.exc 2.0 Sq.m each complete all as specified and directed.
M&L Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S&F 2nd class hard wood 35mm thick Factory made plain framed panelled shutter any number of panels with lock rail and panel of 9mm BWP commercial ply or 12mm veneered partical board with commercial veneering on both faces. The size of rail and stile as per IS 1003 (Part-I), kiln seasoned and chemically pressure treated complete all as specified and directed.
Preparation of new wood or wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
Supply and fixing 100mm long Butt hinges medium weight cold rolled stainless steel, and fixed complete all as specified and as directed.
Supply and fixing 200 mm long aluminium anodized barrel tower bolt extruded section complete all as specified and as directed.
S&F aluminium handles cast type anodised 200 mm long complete all as specified and as directed.
S&F 250mm aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extrudud sections or cast aluminium alloy and fixed complete all as specified and as directed.
S&F in repair looking mirror of size 600mm x 450mm on commerical ply wood 6mm thick with PVC/ wooden moulding beading fixed to wooden plugs with chromium plated brass, screws and cup, washers, aluminium frame and fixed complete all as specified and directed.
Taking down and refixing MS window shutters n. exe 1.5 sqm through cutting of existing any type of hinges, handle and tower bolt and fixing new box type hinges, MS handle and MS tower bolt the same window by necessary welding. The quoted rates shall be included the following aspect:- (a) Cutting of existing piano hinges, handle and tower bolt from window frame and shutter. (b) Fixing of removed shutter in the same frame on MS box type hinges 100mm, MS handle 100mm and MS tower bolt 100mm by welding. (c) Easing and adjusting the shutter before re-fixing if required. (d) Finishing the window frame and shutter with two coat of synthetic enamel paint. (e) Necessary scaffolding material to be included as the building height is more than 10mtr. Note : Box type hinges, handle and tower bolt shall be measured separately as supply only and labour element is deemed to be included in this item.
Supply only MS Box type hinges 50mm.
Supply only MS Handle 100mm.
Supply only MS tower bolt 75mm
Supply and fixing in repair steel window peg stay all as specified and directed.
M&L Machine cut kota stone slab 20-25 mm thick as in flooring, laid over and incl 20 mm thick screed bed in CM 1:3 set and jointed in neat cement slurry and pointed with cement and pigment to match the shade of the slab incl rubbing and polishing including demolition of existing cement concrete and disposal of demolished material upto MD land complete all as specified and directed.
M&L Plain cement concrete (1:3:6) type C1 (20 mm graded stone aggregate), 75mm thick, as in plinth protection courses/footpath, top surface of concrete finished even and smooth with out using extra cement, including expansion joint 10mm thick filled with mastic filling comprising of 01 part of heated blown beitumen and 3 parts of sand including demolition existing cement concrete including disposal of demolition material upto MD land complete all as specified and directed by Engineer- In - charge
Taking down existing manually/machine operated steel rolling shutters area not exc 30Sqm each and erecting in same position, after easening, applying of greasing of all parts in rolling shutters uncluding changing of anchor rod, springs, steel rolling strips, locking plate, ball bearings. locks and vertical channels all as directed. Spare parts shall be measured and paid separately, after replacement of following unserviceable parts as required for smooth functioning of rolling shutter and refixing properly including bracket complete all as specified and directed.
(a) Shaft 50mm mild steel pipe all as directed.
(b) Helical spring 600mm long all as specified and directed.
(e) Ball bearing for 50mm dia pipe all as directed.
(c) Gear box set all as specified and directed.
(d) Lath patty (strips) of 75mm wide & 1.20 mm thick MS all as directed.
(f) Crancked wheel of any size all as directed.
S & F in repairs Steel rolling shutters, in any size and any position with ball bearing, as specified including top cover, anchoring rod, shaft, lath patty,crank wheel, side cover, hood cover, locking plate, hasp and staple and one shop coat of primer; erected in position as indicated, complete manual or gear operated type. Thickness of laths in 1.25mm complete all as specified and directed.
M&L for Preparation of old painted surfaces of steel and applying one coat of synthetic enamel paint over 10 cm width or girth, not other wise described complete all as specified and as directed.
M&L for preparation of new/old any type of surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of floor guard paint over a coat of red oxide primer complete all as specified and directed.
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying one coat of cement based paint complete all as specified and as directed.
M&L for preparation of old plastered surfaces of wall by using pressure washer, removal all dirt and dust and applying one coat of exterior emulsion (APEX) weather proof paint complete all as specified and as directed.
Material and labour for Preparation of old decorated plastered or unplastered surface of wall, chajja, balcony, facia etc., brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent, trading, oil, greasy spots and applying one coat of white wash complete all as specified and directed.
Renewing cement concrete tiles in patches, area n exc 5 sqm including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles complete all as directed. Note : The rate included for cutting out broken tiles, removing and cleaning loose tiles, preparing bed removing rubbish, removing and replaing old with new tiles to match, complete with all cuttings etc, that may be required. New tiles required is deemed to be included all as directed. The unit rate is also including necessary beding in cement mortor/Sand filling.
Supply and fix new fabricatated high intensity standing HIP reflective sign board made from 2 mm thick hardened plastic aluminium combined sheet and two sheets placed back to back fixed with aluminum pop rivited to stainless steel square pipe of size 40 x 40 mm of 16 guage and frame of size 1300 x 840 mm for E/M installations. The frame support shall be of 25 mm and 50 mm round GI Pipe 2.7 mtr length welded to frame. Top end of legs placed with decorative stainless steel dome . All stainless steel parts polished , HIP blue reflective sheet shall be pasted on both side on plastic aluminium combined sheet and pasted with weather proof white fluorescent computer cut tape of required height and width on sign board and border of white HIP sheet shall be pasted and fixed in PCC foundation complete all as directed (Note : Matter for printing shall be provided by the Engr -in - charge)
Supply and fix informative sign board for E/M machineries, plants and Schematic diagrams made up of weather proof 3 mm thick rigid PVC sheet of dark blue back ground pasted on one side with white weather proof computer aided cut tape of required height pasted on sign board incl fixing arrangements by screw/ nut, bolt / riveting of the board in wall/panels/platform/doors/any description complete all as directed. (Note : Matter for printing shall be provided by the Engineer-in-Charge)
Material and labour as in repair for Earth pit indicator for existing earthing pit made out of 16 mm dia and 60 cm long MS Squre Bar embeded in PCC (1:3:6) type C-1 using 20 mm graded stone aggregate in PCC block of size 30 X30 X30 cm including CI/MS plate of size 250X300X 3 mm thick fixed on side of earth pit cover complete painting and writing over the plate ie. Type , Result, Date of measurement and pit number with Black back ground with white and complete all as specified and as directed by Engineer-in -charge.
Surface dressing in hard / dense soil not exceeding 15 cm deep and clearing all the grass weeds etc in the sub station yards after removing stone aggregate aside all as directed at site including setting / spreading back the aggregate complete all as specified and directed at site.
M & L for laying of graded coarse aggregate (broken stone or boulders) of size 40 mm in sub - station yard complete all as directed and specified.
M & L for Rubbered mat of size 2.0x 1.0m and thickness 2mm with ISI marked Complete all as Specified and as directed by Engineer-in-charge.
Supply and Fixing of cable route indicator made up of Cast iron disc 6 inch dia duly engraved as "HT Cable" duly fixed with 450 mm long MS Flat of 40 x 6 mm as support and painted with red in colour on both side duly grouted the MS leg in PCC foundation of 200 mm x 200 mm x 300 mm depth below gound level including necessary required excavation and earth work for foundation complete all as specified and as directed.
Supply and Fixing of cable route indicator made up of Cast iron disc 4 inch dia duly engraved as "LT Cable" duly fixed with 450 mm long MS Flat of 40 x 6 mm as support and painted with silver in colour on both side duly grouted the MS leg in PCC foundation of 200 mm x 200 mm x 300 mm depth below gound level including necessary required excavation and earth work for foundation complete all as specified and as directed
Taking down aluminium/copper point wiring & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to match the existing surface, complete all as specified and directed.
M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn through and including surface PVC conduit/existing concealed conduit/PVC casing-caping ets as per site requirement on walls / roofs / floors / ceiling etc and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly with all fitting and fixing accessories including sunk in cast iron / pressed steel terminal boxes (duly painted with two coats of anti corrosive paint out side and two coats of aluminium paint inside ) with 3.0 mm thick hylum brand laminated white bakelite sheet cover for mounting switches, sockets, fans regulators etc complete for the following :- Make of wire: Polycab/Plaza/Havells Note: (a) Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).
All as per item No. 294 here in before but for One light point/fan point controlled by one way 5 Amp switch.
All as per item No. 294 here in before but for One light point controlled by two way 5 Amp switch.
All as per item No. 294 here in before but for one bell point controlled by one way bel push.
All as per item No.294 here in before but for One 3 pin socket out let 5 Amp on the same board
All as per item No. 294 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per item No. 294 here in before but for Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed.
All as per item No. 294 here in before but for Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed.
Supply and Fix switch piano flush type 5 Amps 240 volts single pole one way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 5 Amps 240 volts single pole two way, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix switch piano flush type 5 Amps 240 volts bell push, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered switch socket outlet 3 pin 5 Amps, flush type, complete all as specified and directed. Make : Anchor/Havells/L&T/Indoasian
Supply and Fix shuttered switch socket outlet 2 in 1, 3 pin, 5 and15 Amps, complete all as specified and directed.Make : Anchor/Havells/L&T/Indoasian
S & F 2.5 mfd condensor for ceiling fan, complete all as specified and directed. Make : Epcos/ Asian/ Tyton
S & F ceiling rose surface bakelight two to three terminal complete all as specified and directed Make : Anchor/Havells/L&T
S & F electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/Havells/L&T
S & F fan regulator 120W, for ceiling fan complete all as specified and directed Make : Anchor/Havells/L&T
S&F in replacement factory made powder coated distribution board SPN 12 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F in repair and replacement TPN, MCB 40 to 63 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC casing caping/ PVC Conduit and all accessories fixed to wall/floors along with 6 Sqmm surface PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one length Make:- Havells/ Polycab/ Plaza.
Supply and Fixing in repairs of 4 feet surface mounted batten type luminaire , lumen output of 2000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . The luminaire and driver shall be BIS approved, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.
S&F in repair of new PVC conduit medium grade of size 25 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make : Supreme/Diplast/Avon plast
S&F in repair of new PVC conduit medium grade of size 20 mm on wall /roof with help of screw and GI shaddle including fixing of existing serviceable copper /alluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make : Supreme/Diplast/Avon plast
S&F in replacement factory made powder coated distribution board VTPN, 4 way double door MCCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB complete all as directed Make : Indoasian/ Havells/ Legrand.
S&F in replacement distribution board MCCB four pole, 160 Amp ultimate breaking capacity 25 KA conforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian
Supply and Fix in repair and replacement of surface mounted Square/Round for LED 18W Watt downlights made of extruded Aluminium housing and high power LED light source with Driver clear diffuser with separate electronic driver with complete accessories all as specified and directed.Make : Philips/ Bajaj / CG/Havells.
M&L for cutting of hole through brick wall with the help of Core cutting machine including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.
M&L for in repair louver made of steel suitable for 300 mm size exhaust fan, fixed on wall including necessary fixing arrengement up to height 11 mtr complete all as specified and directed. Note : All safety measures shall be the responsible of the contractor.
Supply and fixing Exhaust fan 300 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed.Make : Havells/ Bajaj/ Orient/USHA. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard without any extra cost to the deptt.
M & L for Point wiring with PVC insulated FRLS 1.5 sq mm multi stranded copper conductor cable 1100 Volts grade drawn into and including concealed rigid non mettalic PVC conduit/casing caping medium grade not less than 19/20 mm ( ISI marked ) with all fitting and fixing accessories including sunk in pressed steel chromium plated terminal boxes, concealed in wall/surface/roofs/floor/ceiling etc as per site requirement and making & maching the existing surface ) white bakelite sheet cover for mounting switches, Sockets, Fan regulators etc or modular cover plate with frame including sunken boxes suitable to fix modular cover plate with frame , concealed in wall or 1.5 sq mm multi stranded copper conductor cable as continuous earth wire drawn with wiring and connected to common earth dolly complete all as specified and directed for the following :- Make of wire: Polycab/Plaza/Havells Note: Blanking plate,Modular cover plate ,Switches, sockets outlets, Light fittngs, fans, bells & regulators shall be measured and paid for separetely).
All as per item No. 324 here in before but for one light point/fan/bell point controlled by one way switch.
All as per item No. 324 here in before but for one light point controlled by two way switch.
All as per item No. 324 here in before but for one bell point controlled by one bell push.
All as per item No. 324 here in before but for one 3 pin socket out 5 Amp on the same board
All as per item No. 324 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 324 above but Wiring with 2.5 Sqmm copper multistranded unsheathed cable and 2.5 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed.
All as per Sl No 324 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently etc complete all as specified and directed.
Supply and Fix modular switch 1 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular switch 2 way 6 Amp.1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian
Supply and Fix modular switch bell push .1 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor /Indoasian
Supply and Fix modular Socket, 6A - 2/3 pin combined 2 module, complete all as specified and directed.Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and Fix modular switch 1 way 16 Amp.1 module, complete all as specified and directed. Make :Legrand/ Crabtree/ Anchor /Indoasian
Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module, complete all as specified and directed. Make : Legrand/ Crabtree/ Anchor/Indoasian
Supply and fix White cover plate with frame,2/3 module
Supply and fix White cover plate with frame,4 module
Supply and fix White cover plate with frame,8 module
Supply and fix White cover plate with frame,6 module
Supply and fix White cover plate with frame,12 module
S & F Modular fan regulator 120W, 2 Module for ceiling fan complete all as specified and directed Make : Legrand/ Crabtree/ Anchor
Supply and Fixing in repairs of 2 feet surface mounted batten type luminaire , lumen output of 1000 lumens, high efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle not less than 120° to ensure better uniformity with an operating voltage range from 140V-270V. The luminaire shall have a white extrusion housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than 22 mm. The luminaire shall have a CRI >80, Color temperature 6500K, THD <10% and PF >0.95,SDCM<5, IP20, IK02, Operating Temperature: -10 TO + 45 DEG.C; Input Supply Voltage Range:140-270 V, Frequency :50-55 HZ. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature.Driver Safety requirement stds: IS 15885-2-13. The luminaire shall be EMI/ EMC compliant and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability . The luminaire and driver shall be BIS approved, complete all as specified and directed. Make : Philips/ Bajaj / CG/Havells.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size PVC casing caping/ PVC Conduit and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length. Make:- Havells/ Polycab/ Plaza.
S&F in replacement factory made powder coated distribution board VTPN, 6 way double door MCCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB complete all as directed Make : Indoasian/ Havells/ Legrand.
S&F in replacement distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA conforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S&F in replacement factory made powder coated distribution board SPN 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F in repair and replacement TP, MCB 40 to 63 Amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996, all as specified Make : Legrand/ L&T/ Indo Asian
S & F in repair and replacement of MCB single pole 240 volts 6 to 40 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian
S&F as in repair PVC casing capping medium grade of size 32 mm on wall /roof with help of screw including serviceable copper /aluminium conductor and all fitting fixture such as Tee, Elbow and lapping, complete all as specified and as directed. Make: Polycab/ Modi/ Presto Plast
Supply & fix in repair decorative surface mounted ultra slim Square/Round profile 18 W LED(WW/WH) lighting fixture Square shape with extruded polycarbonate, environmental friendly, energy efficient ready to use pack of 18 Watt and including cosidering material & labour for fixing ceiling hight upto 7.5 Mtr, complete all as per site requirement and directed Make : Philips/ Bajaj / CG/Havells.
S & F in replacement 9 watt LED lamp, complete all as specified and directed. Make : Philips/ Bajaj/ Crompton
M&L for cutting of hole through stone wall with the help of Core cutting machine including providing, fixing and removing shoring,cleaning,internal plastering and removing surplus hard core,rubbish not exceeding 50 mtrs including fixing of exhaust fan of size 250-450 mm all as specified and as directed.
Supply and fixing Exhaust fan 250 mm sweep 230/ 240 volt AC single phase PVC body 1400 RPM including necessary nut, bolts / screws including taking down existing one writing MES No with synthetic enamel paint all specified and directed. Make : Havells/ Bajaj/ Orient/USHA. Note:- Old Unserviceable Exhaust fan shall be deposited to MES store yard.
M&L in repair for stainless steel wire cloth 0.63 mm dia of wire and average width of aperture 1:40 mm for covering of exhaust fan hole in wall of size 450 mm X450 mm with PVC/wooden beading fixed on wall including necessary fixing arrangement up to height 11 mtr complete all as specified and directed. Note : All safety measures shall be the responsibility of the contractor
Refixing existing serviceable LED light fitting fixture any capacity and of any type complete with all accessories internally pre-wired and including connecting up to ceiling rose with twin core twisted flexible copper conductor cable with suitable size after cleaning all dust etc. complete all as specified and as directed .
S&F in repairs LED bed side light /wall light/study light environmentel friendly energy effcient of capacity 3 W warm white etc,inbuilt driver complete with all accessories internally pre-wired swing type and including connecting up to with twin core twisted flexible copper conductor cable with suitable size complete all as directed . Make : Bajaj / Philips / Wipro/CG
Supply & Fixing in replacement of electronic LED driver 2/3 W suitable for bed side light fitting as per site requirement complete all as specified and directed .
Supply and Fixing in repairs of wall focus track light 18 watt WW an operating voltage range from 140V-270V complete all as specified and directed. Make :- Phillips/ Lukar /Bajaj/CG
Supply and Fixing in repairs of channel 2 Mtr length for focus track light complete all as specified and directed.
S&F in replacement factory made powder coated distribution board SPN 6 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S & F MCB in repair and replacement of SPN 240 volts 16 to 40 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian
S & F in repair and replacement of MCB single pole 240 volts 63 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian
S&F in replacement factory made powder coated distribution board SPN 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB all as specified and conforming to IS: 8623, all as specified and directed. Make : Legrand/ L&T/ Indo Asian
S&F in replacement factory made powder coated distribution board VTPN, 8 way double door MCCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB complete all as directed Make : Indoasian/ Havells/ Legrand.
S&F in replacement distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA conforming to IEC -61439-1, complete all as specified and directed. Make : Legrand/ L&T/ Indo Asian
Supply & Fixing in replacement of electronic LED driver 18/20 W suitable for round ceiling light indoor fitting of make Philips/ crompton/ Bajaj, complete all as specified and directed .
Supply and fixing in repair building security/ LED street light fitting 36 Watt, 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal, management in multiple optics complete, with IP 65/66 protection complete all as specified and directed. Make: Philips/Bajaj/CG
Supply and fix GI pipe 32 mm dia, medium grade for mounting bracket, bent to shape 1.5 meter length and fixing arrangement with two Nos of clamps set, nut, bolts, washers, and incl taking down old unserviceable GI pipe complete all as specified and directed
S&F in replacement factory made powder coated distribution board TPN, 4 way double door MCB DB including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down unserviceable DB complete all as directed Make : Indoasian/ Havells/ Legrand.
S & F MCB in repair and replacement of SPN 240 volts 63 Amps complete including taking down unserviceable fitting complete all as specified and as directed .Make : Legrand/ L&T/ Indo Asian
Comprehensive maintenance /repair of Effluent treatment plant capacity of 25 KLD, the plant comprising of the following :- Bar screen,Oil Grease Trap chamber, Equalisation tank, Raw effluent Pumps-0.5 Hp, 3 Phase-02 Nos, Anoxic Tank, Floculation and coagualtion tank with stirrer, coarse Bubble Diffusers, MBBR tank, secondary settling tank, Filter feed pump -1 HP, 3 Phase-02 Nos, Air Blower- 5 HP, 50 m3/Hr -02 Nos, pressure sand filter, activated carbon filter, Filter feed tank,Final treated water tank 2000 ltr Capacity,Sludge drying Bed,hypo chloride dozing system - 02 Nos Fine Pore Diffusers and other civil structures/ chambers, connected equipments, panels, cables etc.
(I) The parameters of input and output shall be maintained as under :-
(a) Inlet parameters :- (i) BOD - 350 mg/ltr (ii) COD - 600 mg/ltr (iii) TSS - 500 mg/ltr (iv) PH - 6.5 to 8.5 (v) Ammoniacal Nitrogen - 100 mg/ltr (vi) Total Nitrogen - 50 mg/ltr (v) Faecal Coliform - < 310 MPN/100 ml
(b) Parameters for treated sewage effluent required are as :- (i) BOD - Less than or equal to 10 mg/ ltr (ii) COD - Less than or equal to 50 mg/ ltr (iii) TSS - < 10 mg/ltr (iv) PH - 6.5 to 8.5 (v) Ammoniacal Nitrogen- <5 mg/ltr (vi) Total Ammoniacal Nitrogen < 10 mg/ltr (vii) Faecal Coliform - <100 MPN/100 ml in biological system to be maintained)
(II) The following daily maintenance to be carried out :- (a) Bar screen chamber should be cleaned every day to ensure that it’s not choked. (b) Cleaning of Oil & Grease trap. (c) Once in every two hours pumps should be changed between working and standby i.e, Sewage feed pump, blower and Filter feed pump. (d) Maintain disinfection liquid in chlorine dozing tank. (e) MGF and AGF back wash & rinse – Once in every 8 hours simultaneously. (f) Settling tank – Sludge should be disposed from settling tank to sludge drying bed. Once every 8 hours based on MLSS growth. (g) Monitoring and maintenance of log books periodically. (h) Treated water tank – chlorine content should be analysed to ensure that chlorine % is below 0.2 ppm. (j) MLSS growth – to be checked in aeration tank and equalization .
(III) The following weekly maintenance to be carried out :- A NGP ETP system is inspected weekly and the following points attended to :- i) Inspect Equalisation Tank/ Entry to system for blockages, plastics etc and remove. ii) Inspect Aerator and note biomass growth, recirculation and any malodour. iii) Inspect Secondary clarifier (Humus, Tank) and note visual appearance of final effluent and absence (or otherwise) of sludge build up. iv) Check the outlet of the system for blockage etc. v) Check grease trap empty and if required top up with clean cold water. vi) Grease the bearings
(IV) The following monthly maintenance to be carried out :- Refer the following below mentioned instructions for weekly maintenance schedule. i) Check motor for overheating (by touch) and remove dust etc. from air fins. ii) Grease all bearings through nipples. iii) Grease all chain couplings through casing nipples. iv) Check oil level in gearbox and top up if necessary. v) Check sludge return system from Humus Tank for function. vi) Apply light lubricating oil in small quantities to locks and hinges. vii) Empty and clean out grease trap and fill with clean cold water
(V) The following items for routine maintenance shall be provided in plant :- (a) Liquid chlorine - 25 ltrs per month (b) Urea - 20 kg per month (c) DAB - 12 kg per month (d) Bio culture - 6 kg per month (e) Cow dung - 10 kg per month (f) Deforming chemical - 2.5 ltr per month (g) INDI foam 3000 - 4 ltr per month (h) Sercon 203 - 2.5 ltr per month
(VI) The following items shall be replaced as and when required or as directed by the Engr-in-Charge :- (a) Gaskets, Gland Packing. (b) O rings. (c) Drive belts for air blower and clarifier. (d) Minor electrical accessories viz Indication lamps, fuses etc. (e) Blades (f) Pasting materials (g) Consumables like gloves, safety jackets, helmets, respirators etc (h) Cleaning Chemicals, reagents, Lubricants etc.
(VII) The following tests shall be carried out and maintain the record of treated sewage as per frequency mentioned below :- Ser No Description of parameters Periodicity 1. PH Monthly 2. TSS Monthly 3. BOD Monthly 4. COD Monthly 5 Coliform Monthly 6 Residual chlorine Monthly 7 Dissolved oxygen Monthly
Note for item No 373 :- Provide the following technical services and the quoted rate deemed to be inclusive of the following :- (a) The contractor shall visit the site/ plant before quoting the tender. The existing ETP plant is MBBR type and Original Equipment Manufacture is M/s V A Exergy Technologies Pvt Ltd.
(b) For technical support in comprehensive maintenance of ETP, the contractor shall enter into MOU with the OEMs. No additional payment on this account shall be made to the contractor by the department.
(c) The comprehensive maintenance of ETP plant of MBBR will be carried out through the OEM's personnel under the supervision of contractor and the Engineer-in-Charge. The OEM shall be responsible for all technical support for comprehensive maintenance and shall also be responsible for performance of the plant in terms of outlet parameters mentioned here-in-before.
(d) OEM or their authorised service centre shall employ technician having sound knowledge in ETP Plant to operate the plant, carryout water analysis checks through approved Laboratory and monitor the performance of the plant on a regular basis, interpret the results and suggest remedial measures in case of major deviations and one person for daily maintenance and cleaning of the plant.
(e) Visits of service Engineer of OEM at least once in every month and during break down or when urgently required for the Inspection, servicing repair, rectification of problem and submission of report.
(f) The maintenance supervisor shall be fully responsible for maintaining the ETP in operational condition in consultation with the Engineer-in-Charge.
(g) The cost of supply and replacement of worn out/ defective equipments, each and every type of repair, renewals, regular servicing for efficient and smooth functioning of ETP and connected equipment/ items shall be deemed to be included in the unit quoted rates of BOQ.
(h) Repair/ replacement of any equipment/ machinery or part thereof provided under this contract shall be got done only from the manufacturer's authorised dealer/ OEM.
(j) The contractor has to provide all consumable spares, oil & lubricants for greasing of various equipments, chemicals, consumables for electrical and mechanical plant & machinery.
(k) One month's consumables and required spares shall always be kept at site in advance.
(l) Major repairs/ overhauling etc. shall be notified to the GE immediately on occurrence. The cost of each part/ equipment replaced shall be deemed to be included in the unit rates quoted by the contractor. The rates quoted in BOQ shall be deemed to be included for all materials and labour reqd for comprehensive maintenance including repair/ replacement of all the component equipment for keeping the ETP in operational condition.
(m) The entire treated water will be reutilised for arboriculture purpose. The quality of treated water shall meet all the criteria given here in before.
(n) The contractor shall carry out various tests on treated effluent as per frequency mentioned here-in-before and record the same in registers. The tests shall be carried out from any Govt approved laboratories. Contractor shall also be at liberty to establish his own laboratories at site for same after prior approval of GE, however, GE can ask the contractor to get independent tests from any Govt lab/ Govt Engineering colleges/NABL lab.
(o) The Installation shall be frequently visited by the MES/ Air Force officers. It shall be contractor responsibility for proper upkeep of the area in a presentable state all the time. Surrounding area upto the fencing/ boundary of ETP shall be kept clean and cleared of bushes/ shrubs and grass all the time to give a neat and clean appearance of the area.
p) Repair to system in case of break down (due to normal wear & tear) shall be rectified by the contractor within 24 hrs. In case of failure noticed more than 24 hrs, recovery shall be effected @ Rs. 500/- per hour beyond 24 hrs.
(q) Disposal of all sludge at suitable frequency outside the defence land. Contractor is deemed to have identify the area suitable for disposal for sludge. The cost of disposal of all sludge shall deemed to have been included in the unit quoted rates.
M&L for repair/maint of Pressue Sand Filter of Effluent treatment plant capacity of 25 KLD, opening top cover of sand filter tank for taking out all filter media i.e. sand, gravels, strainer with complete connection of pipes & valves and repairing the same including re-filling of existing filter media /chemicals after washing and topping up of filter media/chemicals as required and testing complete all as specified and as directed. Notes:- The fwg points is deemed to be inclusive in unit quoted rate :- (i) Keeping leak proof of whole Pressue Sand Filter assembly including all types of valves, replacement of rubber hose, clamps, etc. (ii) Topping up of all filter media to Pressue Sand Filter like gravels, sand, strainer etc. (iii) Disconnect & interconnect pipes of any sizes, valves, gauges, and all accessories etc., including reassembling the whole DMF by welding/ jointing etc. (iv) Cost of labour elements towards removing of unserviceable items & refixing of serviceable items for below mentioned supply only items will be deemed to be included in unit quoted rates.
Supply only Fine Sand
Supply only Coarse Sand
Supply only 1"X3/4" Pebbles
Supply only 3/4"X1/2" Pebbles
Supply only 1/2"X1/4" Pebbles
Supply only 1/4"X1/10" mm gravels
Supply only MBBR Media in the Bio culture tank of ETP Plant of make as approved by GE complete all as specified and directed.
Chemical testing of treated Effulent water of sample taken from various ETP locations at SMC AFS Jalahalli East through a Central/ State Govt/ NABL approved lab. The following test should be carried out :- (a) PH (b) TSS (c) COD (d) BOD (e) Coliform (f) Residual chlorine (g) Dissolved oxygen
Cleaning of UG sumps with bypass arrangement of following capacities by involving the following cleaning process complete all as specified and as directed :- (a) De-watering by high pressure submersible pump (b) Removal of sludge from sump. (c) Cleaning of walls, floors, ceiling etc by high pressure jet pump 80 - 100 bar pressure all complete. (d) Removing dirt and sludge by vaccum pump.
Bar Screen Chamber of 132 ltr capacity at SMC ETP
Oil Grease trap of 470 ltr capacity at SMC ETP
Equalisation tank of 1000 ltr capacity at SMC ETP
Anoxic tank of 7200 ltr capacity at SMC ETP
Flash Mixer tank of 312 ltr capacity at SMC ETP
Flocculator of 65 ltr capacity at SMC ETP
Primary settling Tank of 2500 ltr capacity at SMC ETP
MBBR Tank of 15000 ltr capacity at SMC ETP
Secondary settling Tank of 5000 ltr capacity at SMC ETP
Filter feed tank 500 ltr capacity at SMC ETP
Final treated tank of 2000 ltr capacity at SMC ETP
M& L for preparation to external surface of complete ETP plant ie pipes of various size, valves, various size of tanks and filter etc and completely removal of existing paint by scraping or chemical and surface painted with synthetic enamal paint/ weather proof paint with one coat of primer with help of brush complete all as specified and as directed by Engineer-in-Charge. Note :- Colour of paint as recommended by Engr-in-Charge.
M&L for repair/maint of Activated Carbon filter of 25 KLD Effluent Treatment Plant, opening top cover of Activated Carbon filter tank for taking out all filter media i.e. Activated Carbon ,sand, gravels, strainer with complete connection of pipes & valves and repairing the same including re-filling of existing filter media /chemicals after washing and topping up of filter media/chemicals as required and testing complete all as specified and as directed. Notes:- The fwg points is deemed to be inclusive in unit quoted rate :- (i) Keeping leak proof of whole activated carbon filter assembly including all types of valves, replacement of rubber hose, clamps, etc. (ii) Topping up of all filter media to Filter Assembly like gravels, sand, strainer etc. (iii) Disconnect & interconnect pipes of any sizes, valves, gauges, and all accessories etc., including reassembling the whole Filter Assembly by welding/ jointing etc. (iv) Cost of labour elements towards removing of unserviceable items & refixing of serviceable items for below mentioned supply only items will be deemed to be included in unit quoted rates.
Supply only activated carbon with 600 IV Grade : 4X8 Coconut shell carbon
Taking out of solid dry effluent waste from sludge drying bed of size 1.5 X1X 1 meter and disposal of same outside the Defence land.
M&L for servicing of ETP pump electrical panel which operates maximum twelve pumps by checking and servicing the contactor coil, over load relay coil and any other parts and replacement of the burnt out wiring including any modification to fire pump panel by welding,cutting ,grinding ,drilling and rewiring with proper colour coding and testing the panel in auto/ manual mode complete all as specified and directed. Notes :- (i) Minor spare parts such as nuts,bolts ,washers ,indicator lamps , start,stop push button and suitable size of copper wire for internal wiring of panel are deemed to be include in quoted rate.
Supply and fixing of 1100 volts grade heavy duty cable of size 2.5 Sqmm PVC insulated 3 core , served with inner sheathing of PVC tape and overall PVC sheathed incl taking out old unsv complete all as specified and directed
Supply and laying in repair of GI pipe light grade for cable protection of size 80mm bore with fittings, complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, class EHV, type 2 with flat, size 450mm x 180mmx 40mm, all as specified and as directed.
Supply, lay, test and commissioning of XLPE insulated screened PVC bedded, galvanised steel strip or wire, armoured, heavy duty electric power cable (HTUG), 11000 volts grade with stranded aluminium conductor of size 3 core 120 Sqmm ( Earthed) including takingout existing unserviceable cable complete all as specified and as directed. Make :- Havells, Polycab, RPG Asian Note - Earthwork and bricks to be paid separately in respective items.
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for outdoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95-120 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed. Make : Densons/ M-Seal/ 3M
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for out door straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95-120 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed. Make : Densons/ M-Seal/ 3M
Material and labour for cable jointing kit for 11KV (Earthed) grade cable for indoor end termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95-120 Sqmm and testing after jointing including taking out unserviceable joint kit complete all as specified and as directed. Make : Densons/ M-Seal/ 3M
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. including excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 Sqmm 3 core complete all as specified and as directed. Notes : (i) The contractor shall bring the fault locating equipment at site with in 02 hours of instructions received from Engineer -in- charge and he shall ensure that the fault is rectified with in 8 hours of receipt of intimation through telephone from Engineer-in-charge failing which recovery of Rs. 10000.00 per hour shall be recovered from the contractors dues w.e.f the time immediately after the expiry of 24 hours duration. (ii) For the purpose of payment one unit of “Each job” shall comprise of detection of faults in a particular stretch of cable which are identified in that particular stretch, irrespective of number of defects / faults in that particular stretch which are detected during fault detection and the contractors unit rate quoted shall be deemed to include for the same and all such defects / faults which are detected in that particular stretch shall be considered as one unit. (iii.) Joints, jointing materials and cable required shall be measured and paid for separately
Material and labour as in repair for fixing aerial fuse wire of suitable for HT 11 KV drop out fuse carrier up to 20 A rating complete all as specified and as directed.
Material and labour as in repair for fixing aerial fuse wire of suitable for HT 11 KV drop out fuse carrier up to 30 A rating complete all as specified and as directed.
Material and labour for fixing aerial fuse wire of suitable for HT 11 KV drop out fuse carrier up to 40 A rating complete all as specified and as directed.
Supply and fixing as in repair HT tape roll 35mm width Appx 5 mtr length (ISI marked) all as specified and directed
M&L for leak testing with pressure testing of SF6 gas of RMU units and rectifying the leakage by gas welding / brazing , complete pressure testing and SF6 gas charging in the RMU unit , testing and commissioning complete all as specified and as directed. Make of RMU : ABB/Siemens Note :- (a) SF6 Gas shall be paid and measured separately. (b) The work shall be executed all as per OEM recommendations.
Supply only SF6 Gas in manufacturer's sealed cylinder complete all as specified and as directed.
Supply and fix in repair MCCB of capacity 400 Amps 415 Volts 4 pole with breaking capacity 36 KA in LT panel boards / feeder pillar boxes including disconnecting existing from electric connection including necessary connecting fastners, burnt cables, accessories like spreader ,cages etc all as per site requirement/existing make/model, complete all as specified and directed. Make : Indo Asian/L&T/Havells
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No. of 16 A 3 Pole IP65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board all as directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 250 Amps, 36 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amps, 25 KA - 01No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amps,10 KA - 02 Nos. (d) MCB SPN of 240 V of capacity 40 Amps, 10 KA - 02 Nos. (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (g) Space for spare feeder - 01 No. Note :- (i) The Contractor Shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Supply, installation, testing & commissioning of maintenance free chemical earthing system comprising of 17mm dia copper bonded rod 3 mtr long horizontally pre welded T-terminal rod with provision for connection size of 50 x 150mm long, 6mm thickness with equal space either side, with 12mm dia hole of 02 numbers each on either side of the terminal clamp with 250 microns (average) coating thickness, tested and certified by CPRI India alongwith 50 Kg earth energizer compound and 10 litres earth resistance reducing liquid. The earthing energizer compound and resistance reducing earthing liquid shall be tested as per IEC-62561-7 read with ASTM G57-06, CI 3.4 A by any NABL accredited lab. The above mentioned rod shall be installed in 4-6 inch bore, 12 feet depth with a distance of minimum 3 meters between each installation including taking down existing one, complete all as specified and directed.. Make : Model HTSP 317 of safeTrode or equivalent in Snaga/ Cubes 6 Global
The quoted rate shall also deemed to be included the following :- (i) Prior to installation of maintenance free chemical earthing, soil resistivity test to be carried out at the location where earthing work to be done in presence of Engr-in- Charge/JE (E/M),user and the report has to submit to Garrison Engineer with recommendation of manufacturer, if required additional interconnection of earthing (not more than 08 number of earthing) to achive earth result less then 1 Ohms. The arrangement done for soil resistivity testing and submission of report with recommendation deemed to be included in the quoted rate.
(ii) The description/ size/ qty of items mentioned in above are for indicating only however qty/ size may vary at site condition to maintain the earth resistance 1 ohm. The contractor shall quote rate by considering all factors.
(iii) Rate of earth energizer compound of 25 Kg of 02 bags and earth resistance reducing liquid 10 litre per cane for each pit deemed to be included in the quoted rate.
(iv) Resistivity of earth energizer compound and resistance reducing earthing liquid shall be certified by any NABL accredited lab carried out as per IEC-62561-7 read with ASTMG57-06, CI-3.4A and the certificate of same shall be submitted by the contractor along with the sample approval
(v) Earth enhancing material should not leach into the adjacent soil or underground water channels and its PH value should be in neutral range complete all as specified and as directed. It should solidify when mixed with water and set like concrete.
(vi) Copper strip of size 20 x 3 mm shall be fixed on proper post insulator at the instrument end (copper strip upto 7.5 RM shall be considered in unit quoted rate and extra will be measured and paid separately).
(vii) Testing of earth shall be carried out in presence of departmental and user representative and report shall be submitted to Garrison Engineer duly signed by all concerned.
(viii) Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(ix) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. After testing if the desired earth resistance of less than 1 Ohm is not obtained, the earthing will be redone at no extra cost to Govt. till desired result is obtained.
(x) The contractor shall give a written guarantee of minimum three years for maintaining the earth resistance less than 1 Ohm after certified date of completion.
(xi) No further maintenance or periodic watering or recharge shall be required in earthing during its guarantee period of over 03 years in all type of soil including soft/ disintegrated or hard rock.
(xii) During the guarantee period, if earth resistance is not maintained less than 1 ohm the contractor has to redo or rectify at no extra cost to Govt till desired result is maintained.
(xiii) A security deposit of value equal to 2.5 % of the rate quoted for chemical earthing for each earthing shall be retained from payment due to the contractor from final bill for the guarantee period.
(xiv) The electrode shall carry manufacturer's name .
(xv) The connection clamp shall be permanentlly welded to the copper bounded rod to avoid any kind of connectivity loss,.The pre-welded copper bounded rod shall not need any additional clamp for termination.
(xvi) The acceptable earth resistance at earth busbar/ test point shall not be more than 0.1 ohm.
(xvii) Earth work such as auguring and making good the surrounding area shall carried out in any type of soil.
(xviii) The contractor shall submit CPRI India certified document for copper bounded rod to ensure genuineness of material.
(xix) Sign board of mild steel sheet 2 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide Zinc chrome primer showing result of earthing shall be fixed near the earth pit after completion as directed by engr -in- charge.
Material and labour for Earth pit cover made of heavy duty poly plastic of high grade polypropylene tested and certified by any NABL accredited lab for load bearing capacity not less than 7.2 tonnes with top dia not less than 250mm, bottom dia not less than 330 mm and height not less than 260 mm for each electrode pit complete including taking down old one complete all as specified and directed. Make : Model SEPC 250 of SAFE TRODE or equivalent in Snaga/ Cubes 6 Global
S&F in repair copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc including taking down existing old unserviceable copper strip etc, complete all as specified and directed. Note : - All Joints should be joined by Exothermic Welding or Brazing.
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panel, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be minimum 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel shall be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32Amp 5P IP 65 industrial socket. 3 Phase and neutral 250 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board complete all as specified and all as directed and comprising of the following:-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 125 Amp, 36 KA - 01 No (Incomer). (b) On Load change over front operated of capacity 160 Amp, 4 Pole, 415 V- 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10KA - 04 Nos. (d) MCB SPN of 240 V of capacity 40 Amps, 10 KA - 03 Nos. (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No (d) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (e) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (vi) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Supply, installation, commissioning and testing of factory assembled, floor mounted, free standing type tested LT Feeder pillar panels, with canopy, as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycarbonate, should be weather/vermin proof, anti -acid, anti-corrossive, UV resistance in accordance with IEC 61439-1, fire retardant and self extingushing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties, RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thromoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosure should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with one No. polycarbonate IP 65, 9 W LED translucent bulk head luminaire color lamp not less than 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with one No of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 600 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate for bedding upto a height of 45 CM above ground level, including dismanting and taking out unserviceable old LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 400 Amp, 36 KA - 02 Nos (Incomer). (b) On Load Change over front operated of capacity 400 Amp, 4 Pole, 415 V - 01 No. (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA - 01 No. (d) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (e) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set. (f) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as mentioned in list of makes (PS).
Note :- An amount of Rs 2,33,707.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
SREE BUILDERS (BID ID -3427580)
RAMESH BABU CO (BID ID -3426973)
Moulya Builders (BID ID -3427237)
Maruthi constructions (BID ID -3428955)
M/S SRI BALAJI ENTERPRISES (BID ID -3428618)
devan enterprises (BID ID -3427912)
K T ASSOCIATES (BID ID -3429163)
RMK PROJECTS (BID ID -3429115)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .