Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC | L1 | Accepted-AOC lowest and reasonable | |
| 2 | L2₹46.0 L+₹2.5 L (5.75%)Rejected-Finance 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹47.1 L+₹3.6 L (8.34%)Rejected-Finance | L3 | Rejected-Finance In order but L3 |
Tender Value
Refer Docs
EMD Value
₹94,240
Closing Date
24 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(U)E/M Meerut
Roorkee road Meerut Cantt
PROVN OF CERTAIN REVENUE AND MINOR WORKS UNDER AGE E/M (ES) AT GE (U) E/M MEERUT.
2022_MES_523291_2
8435/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
Yes
GE(U) E/M Meerut
₹94,240
Yes
20 Jul 2022
3 Jun 2022
27 Jun 2022
3 Jun 2022
24 Jun 2022
10 Jun 2022
Amount
Excavation in truches in soft/loose soil n. exc. 1.5 meter wide and n. exc. 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for fixing pole/stay assembly and laying/taking out cables complete all as specified and directed.
Returning, filling trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavated material (soil) to a distance n. exc. 50 Mtr and dispositing where directed at a level n. exc. 1.50 Mtr above the starting point complete as directed.
M & L Sand cushioning to UG cables (8cm deep before laying of cable and 15 cm deep over the cable). Note :- Punned thickness only will be considered for payment.
M & L Burnt Clay fly ash bricks for protection cover to under ground cable (with standard size fly ash bricks) with width equal to length of brick laid dry and flat abutting each other complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed.
S&F PVC insulated wire copper conductor 3 core 2.5 Sqmm for connection junction box to street light complete and as directed by Engr- in- charge.
S&F 20 mm external dia. Rigid non metallic PVC conduit medium grade, exclusive of boxes ( Junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers , lock nuts, saddles, pipe hook, etc. fixed to poles with suitable size of PVC straps at every 50 cm complete all as specified and directed.
Supply installation testing and commissioning of 3 phase 5 KVA, ICMS (Individual Control management System) central LT panel with on off of contractor for collective control, with one input and Two out put MCB, 3 phase panel meter, remote data monitoring, notifications of faults, suitable for surge protection, rotary switch for manual operation, 2mm, MS sheet enclosure with proper earthing arrangements complete all as specified and directed. Note :- The ICMS have to following features :- (i) Input to ICMS shall be 3 phase/1phase grid power input and with 3 phase (Common phase/individual phase control)/1 phase output for load with option to switch on and off the load. (ii) ICMS shall able to measure voltage, current, power factor, Active power, apparent power, metering cumulative active energy, metering cumulative apparent energy. (iii) Time scheduling which could be defined from the GUI running locally in smart device. (iv) Communication-GPRS communication between ICMS and cloud server street lights for futuristic expansion. (v) Wireless local control for field staff to on/off ICMS in case of ICM failure. complete all as specified and directed.
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron / Mild steel base plate, CI finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work in soft/ loose soil , PCC 1:3:6 type C2 in foundation and around poles and PCC 1:2:4 type B1 as in plinth block duly finished even and smooth without using extra cement, disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting exposed surafces steel tubular poles with two coats of aluminium paint over one coat of red oxide primer and and black bituminous paint on steel surafces embedded in concrete and providing 300 mm wide bands (5 bands/ straps with fluorescent synthetic enamel paint in alternate colour of black and white from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
supplying and fixing 40mm nominal bore Galvanised mild steel pipe /tubing, light grade for protection of earth lead / passing cable complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified (Excavation & Earth work , Mild steel clamps, bolts , nuts and washers shall be measured and paid separately)
M&L for auguring of hole suitable for passing 40mm to 100mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line specified and directed coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified. Note: Pipe shall be measured and paid separately under appropriate items and any dahage to existing cables of anytype shall be made good by the Bidder without any extra cost to department.
S&F 40 mm nominal bore GI pipe brackets made out of light grade pipe of required length not less than 1.50 M consisting adapter to suit the opening of street light fitting, mounting brackets made out of 350 mm long or higher mild steel FI 40x6 mm required shape ( two Nos per GI pipe brackets ) duly fitted with 4 nos Mild steel bolts 10mm dia ,50mm long with nut and washers to poles etc. and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer; complete all as specified.
S&F FRP pole mounting type junction box factory made of size 300x200x105mm with front openable hinged door , locking arrangements, with 4 Nos aluminium bus bars 40 Amps rating mounted on porcelain insulator, cable glands and lugs consisting DIN type rails for fixing MCB DP 6/10 Amps, 10 kA, suitable for domestic loading -01 no. including mild steel flat iron clamp made out of 40x4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.(MCB shall not be measured and paid separately and shall deemed included in the unit rate)
S&F and testing of energy saving & environment friendly LED street light 90 Watt of RF based having provision of SLC ( street light Controler)Street light is made up of die cast aluminium body having IP 66 protection secondary option for better distribution of light and must have 4 KV internal and 10 KV external surge protection. Make:- polycab,HPL,Wipro
M & L for Street Light Controller (SLC) It shall have inbuilt IEEE 802.15.4 compliant wireless radio based on 2.4GHz. The SLC enabled streetlights form a mesh network and support two-way communication with the cloud based lighting management server software via a Gateway. It should support 0-10V analog Dimming. Digital input support for connecting sensors. It shall have support of fault detection and energy monitoring at fixture and shall send the notification to Gateway to be reported to the server. It shall have minimum communication range upto 500 meters with near line of sight. It shall support smart mesh topology and should be a self-forming, self-healing network. It shall have data security of 128 bit AES encryption with support of over the air remote firmware and configuration upgrade. It shall support group creation. It shall support rules implementation to support ITTT logic implementation. It shall support time schedules, to be stored locally and executed even if gateway is not installed. It should support astro timer. It should disconnect power to LED driver if the voltage is outside the acceptable range configured. subscription of 5 years make Tata,polycab ,Hagers,L&T Make:- polycab,HPL,Wipro
M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate ot less athn 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia.(7.50 m Long) by means of nuts, bolts and washers, checknuts of GI and protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe medium grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wiremesh, earthing test point etc complete including necessary earth work and excavation in any type of soil , PCC 1:3:6 type C1 earth pit and Precast RCC cover 40 mm thick in plain cement concrete 1:2:4 type B1 duly reinforced with 8mm dia TMT bars @ 150mm c/c with 10mm dia MS round bar as in lifting handles, mild steel angle iron frame for pit cover made out of 40x40x5mm thick duly painted with two coats of ssynthetic enamel paint over a coat of priner , excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate number 03 of SSR Part I
Supply, installing, testing and commissioning, factory made and tested . LT feeder pillar box (KIOSK) , outdoor type, (Size900 x 600x 500mm) platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated aluminum bus bars 250 Amps rating installed with colour code hydrographic insulation tape of capacity minimam 250 Ampson porcelain insulators. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x4mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) stranded lock with 2 keys, internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 10 Sqmm. The following items accomadated this feeder piller incl 2 nos danger notice plate made of 1.6 mm thick mild steel sheet, vitreous enamelled white of size 25 x 20 cm with letter figures and conventional skull bones in signal red colour and fixed nuts, bolts and washers etc with voltage and danger indicated in Hindi and English complete all as specified and directed Engr in Charge.The scope of work includes the following items accomadate the same panel:-
(a) Incoming :-
(i) MCCB TPN 4 pole, 415 Volts 100 Amps rating 25 KA rupturing cap : 1 No (Make Hager No: HHA064Z/ Legrand /SIEMENS)
Indicator lamp LED type (R, Y, B) complete with fuse -01 Set
(b) Outgoing :-
(i) MCCB TPN 4 pole, 415 Volts 63 Amps rating 25 KA rupturing cap : 1 No (Make Hager No: HHA064Z/ Legrand /SIEMENS)
(ii) Space for MCCB - 1
(i) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, brick work in CM 1:6 with sub class `B’, old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 60cm above ground level and below ground level 40cm.
(i) All out going feeders shall be connected by cable through suitable size gland plate / glands.
(ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint
M&L plate earthing for feeder pillar box complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 40 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of LT equipments etc at the other, earth strip encased in and including 50mm bore GI grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 4 mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate and RCC cover complete all specified and shown in electrical plate No 3 of SSR Pt-I.The scope of work also includes necessary excavation and earthwork
Supply, errection, Installation , Commissioning& testing of High Mast lights(As per surya lumineries heigh mast lights detail under mentioned Technical data cart part Specification inclosed) (Make: (SURYA / Philips/ CG/ BAJAJ/ HAVELLS) comprising of the following-
(a) Supply of galvanized Steel mast of 20 mrts height Mast lighting system technical data with the scope of work
(b) Steel mast height 20 Mtr (galvanizing std IS 4759 )( Material construction of high mast sheet will be of BSEN 10025 / lS 5986 Gr Fe 510 or equivatent) cross section of mast 20 sided polygon ;No of parts along length 2 ( Top dia 150 mm (A/F) & bottom dia 460 mm (A/F)
(c ) Part 1: 8301 mm (Bottom) thickness 4mm ; Part 2: 8300 mm thickness 3 mm
(e) Metal Protection - Hot dip galvaizing internally & externally
(d)Tickness of galvanization - avarage coating 86 microns for > 5mm sheet thickness/65 microns for <5mm sheet thickness
(e) Base plate details :- base plate dia : 670 mm, thickness : 25mm
(f) Lightning protection finial - 1.2m Galvanized, single spike
(g) HD bolts dia 24mm/ HD bolts Nos : 8 / HD bolts PCD 445 mm/ HD bolts embedded length as per manufacturer TDS
(h) Material construction : 40 NB ERW class B Sq pipes or circulor pipe with 6 arms
(j) Dia of lantern ring - asper head frame design in two halves
(k) LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. -9 Nos
(l) LED type twin Aviation obs light (cat no ; 108 DD LDR- SEN IP 66) - 01No
(m) Wind 2 drum manual and power operated , Speed 50m/sec; terrain category- 2, Class-A, incl 3 phase 415 volts 1.5 HP power tool)
(n) Stainless Steel wire Rope : grade AISI 316, 7/19 Con , dia 8 mm braking load minium -2500 Kg
(o) service Wiring feeder to flood light FRLSH , IS- 694 copper cable size 4 Sqmm (minuium) x 3 core
(p) M&L plate earthing for feeder pillar box complete with galvanised mild steel plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 40 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate at one end and connected to metallic bodies of LT equipments etc at the other, earth strip encased in and including 50mm bore GI grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25 x 4 mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate and RCC cover complete all specified and shown in electrical plate No 3 of SSR Pt-I.The scope of work also includes necessary excavation and earthwork.- 3 Nos
q) Supply, installing, testing and commissioning, factory made and tested . LT feeder pillar box (KIOSK) , outdoor type, (635x500x230mm) platform mounted, The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm CRCA MS sheet and 40x40x4mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front opening type, with aprons for cable entry, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) stranded lock with 2 keys, internal wiring with PVC insulated, stranded copper conductor, FRLSH cables, IS-694 marked of adequate size but not less than 10 Sqmm. The following items accomadated this feeder piller incl 2 nos danger notice plate made of 1.6 mm thick mild steel sheet, vitreous enamelled white of size 25 x 20 cm with letter figures and conventional skull bones in signal red colour and fixed nuts, bolts and washers etc with voltage and danger indicated in Hindi and English complete all as specified and directed The scope of work includes the following items accomadate the same panel:-
(i) Stag type,4 way terminal(I/P) 63 Amps - 1 No (PCB 150 ACBC)
(ii) MCCB 40Amps 4 pole - 1No (Legrand / L&T/ Siemnes)
(iii) Contactor 3pole 32Amps -1 No (havells/ L&T/ Siemens)
(iv) toggle Switch 6Amps - 1 No (unique)
(v) timer (analogue) with battery backup -1( L&T, IndoAsian)
(vi) Stage type, 4way terminal (O/P) 63A - 1 No (PCB 150 ACBC
(vii) Over load relay 2/3.5A - 1 No ( L&T/ Siemens/ hager )
(viii) F. contactor 9A - 1No (L&T/ Siemens)
(ix) R. contactor 9A - 1No (L&T/ Siemens)
(x) Motor terminal 32Amps -1 No (ACBC)
(xi) Push switch terminal(STD)-1No (Elach)
(xii) Push switch (F/R) STD - 1 No (Airon)
(i) Work to be executed as per standard engineering practices and as per manufacturers instruction
(ii) Before placing the order the design/ drawing of high mast of there manufacturer shall be got approved by GE
(iii) Work to be executed by the manufacturer or there authorized rep and and undertaking of the same from the manufacturer be submitted prior to excution / completion
(iv) Size of RCC foundation Shall be carried out as per manufacturers drawings
(vi) Make : SURYA/BAJAJ/PHILIPS/HAVELLS/CG
(vii) complete all as specified and as directed Engr in Charge
M&L including jointing testing and commissioning XLPE insulated heavy duty electric cable with aluminium conductor 1100 volts cross section area (ISI marked) laid in trenches, ducts, pipe or fixed on pole etc of size 50 Sqmm, 3.5 core cable all as specified and directed.
Supply & laying galvanised steel water tubing 50mm bore , light grade, IS-1239 marked with all fittings (IS marked) and laid in trenches / under roads / in drains / fixed to poles/walls ( with required size flat iron clamp bolts, nuts and washers ) pipes :-
M&L PCC (1:4:8)type D2 with 40 mm graded crushed stone aggregate infoundation(below pole )
M&L cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate for foundation of stay assembly/struts/pole etc. (around the poles in pit)
M&L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate for coping / pedestal of poles including necessary form work, fair finishing to exposed surfaces using extra cement
S&F and testing LED street light fitting 90 Watt 230 volt,50 Hz, AC outdoor type with high pressure die cast aluminium hosting and heat resistant commplete with driver, lamp bracket with impact corrosion resistant including thermal management in multiple optics complete with IP 66 protection @ 4Kv internal 10 Kv external to driver with superior finish with top maintainable driver compartment coomplete all as specified and directed Engr-in-Charge
Supply & fixing Unplasticised PVC pipes of prssure rating 10Kgf/cmSq 25 mm bore and 3mm thick complete fixed on pole using suitable clamps nuts & bolts (not less than 03 Nos) complete all as specified and as directed
S&F one runs of three core 2.5 Sqmm x3 core (nominal area) PVC insulated and PVC sheathed multi stranded unarmed aluminium conductor cable LT 1100 volt grade Confirming to IS : 7098 FRLS(Inner Sheet) drawn through GI pipe for connecting to street light and pole JBs and one run of PVC insulated and all complete as specified and as directed. (MAKE: POLYCAB,FINOLEX, MESCAB, KEI)
Supply ,Laying, jointing & testing XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, of size 95 sq mm, 3 core, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed. (Note;- Rate quotted includes road cutting/ wall cutting/ trench crossing /floor cutting and making good damged portion matching with existing surface with all existing finishes.)
Excavation in trenches in soft/loose soil exc. 1.5 meter wide and exc. 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for fixing pole/stay assembly and laying/taking out cables complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable covers class HV, Type I, flat, size 300mm x 180mm x 40mm, ISI marked complete all as specified and directed.
Supply and errecting steel tubular pole swaged type 11.0 Meter long, type 410 SP-55, IS-2713 marked complete with M&L for mild steel base plate (fillet welded to poles), pole cap/final taper plug, bolts, nuts, washers etc. including necessary excavation and earth work in soft/ loose soil , PCC 1:3:6 type C2 in foundation and around poles and PCC 1:2:4 type B1 as in plinth block duly finished even and smooth without using extra cement, disposal of surplus soil to a distance not exceeding 50 m and depositing where directed. Painting of poles with one coat of red oxide primer and two coat of aluminium paint before fixing and one coat of aluminium paint after fixing on exposed surfaces and embedded portion shall be painted with two coat of black bituminous paint including the portion above coping shall be painted in alternative 05 Nos bands/straps of black & white colour starting with white colour (each band of 30cm wide) by two coat of synthetic enameled paint up to 1.5 m height complete all as specified and directed by Engr-in-Charge.
Supply and fixing cable jointing kit termination outdoor type for HT 11KV grade cable for end termination joint suitable for XLPE armoured aluminium conductor cable of 50 to 95 Sqmm size, 3 core complete with jointing material (Heat shrink type) with accessories and testing after jointing complete all as specified and directed.
Supply & fixing or laying galvanised steel tubing light grade (ISI marked) of100 mm bore for protection of under ground cable on poles/ walls/under road crossing etc including suitable size iron clamps with nuts, bolts & washers for proper fixing of pipe complete all as specified and directed.
M & L for Boring of holes under 1.5 to 2 Mtr below road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure. Any damage to existing cables of any type and road will made good by the tenderer without any extra payment.
Supply & fixing HT PCC cable route indicator of size 175mm x 150mm thick, 75 cm long and upper front side each indicator shall be embracing 4mm deep with words "HT CABLE" and two coats of synthetic enamel yellow and red paint along HT cable trench after every 50Mtr and corner & on any turnning, road crossing etc including planting in ground with PCC (1:3:6) type C-1 complete all as specified and directed by Engineer-in-Charge.
Suuply & Fixing 11000 Volts Danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 25X20cm size including taking down.
Supply and fixing pre-fabricated MS structural steel (IS marked) work consisting of channels / angles / other sections etc of various sizes and shape, cut / weld / drilled holes etc hot / cold in position for cross arms with FI clamps (full, half D and earth clamp etc) incl necessary MS bolts, nuts etc and painting, all as directed and specified.
M&L on load, single air brake tilting type, gang operated switch with drop out fuse assembly ( GO/DO) , tripple pole, out door type, both horizontal and vertical mountining, mechanically operated , mounted on vitreous porcelain post insulators ( 03 Nos on each pole for GO and 01 Nos on each pole for DO), 200 Amps continuos current rating, rated voltage 11000, system voltage 12 KV, 50 Hz, V rating,consisting of ISMC -75 galvalised Base channel, fixed and moving contacts, terminal pad of tinned copper,arcing horns, copper connecting flat, stainless steel springs, GI rocker system, phae coupler rod, Galvanised mild steel 25mm nomonal bore medium grade pipe 5-6m long, fibre glass fuse carried, tinned copper male and female contract for DO, etc. complete having adequate distance between poles, live parts and earth and isolation complete all as specified and directed. All Mild steel parts hot dipped galvanised and copper parts tinned plated conforing to IS-1818,IS-9921 and 9385.
S&F Energy saving & environment friendly LED street light made out of pressure die cast anodised aluminium housing with polycarbonate or flat glass optical cover, system power euqal to less than 70 watt with penut lens to achieve B1 class road illumination as per IS: 1944 and as per national lighting code, Luminous of efficiency of LED >= 135 Lumens/Watt, ,CRI >70, CCT > 5000K to 6500 K with LED life span at 70% of light output >50000 hours (L70) with suitable driver 140V to 270V universal type, with bult in surge protection >5KV, 50 Hz +/- 3% , pf 0.95, THD <10% with system efficiency >85 lumens/ Watt and power efficiency >=90% and overall IP 66 or better , , driver and luminaire shall comply LM-79/IS:16106 complete all as specified and directed complete all as specified and directed by EIC.
Supply, installation,commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage 80 litres and nominal cooling capacity 40 litres per hour complete all as specified and directed.Make Voltas/Blue Star/Godrej
Supply and fix voltage stabiliser for automatic operation , single phase naturaly air cooled indoor type and designed for input variation between 170 to 270 volts with out put voltage stabilised at 230 volts with accuracy +/- 1% , Operating frequency 50 Hz, Response time <3 msecs, Operating Temperature 0-55 Degree C ,Duty of operation Continuous at 100% , Rate of Correction 15 to 40 V / Sec and of capacity 2 KVA complete all as specified and directed.
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of minimum 4000 CFM or higher size per hour (or nearest size).Plastic/PVC Body complete all as pecified and directed.
Material & labour point wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, stranded, PVC insulated, unsheathed (FRLS) copper conductor cable in and including PVC conduit/casing caping of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories/fittings, brass screws, washers etc, Sunk Zinc coated pressed steel terminal boxes including all cutting/chases etc in walls, making good to walls, ceiling etc including two coats of white/colour washing/ distempering etc to the disturbed surfaces to match the existing with 3 mm thick plastic laminated sheet top cover concealed in wall with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, PVC insulated copper stranded conductor cable, unsheathed and connected to common earth and earth dolly complete all as specified and directed for the followings.
(a) One 3 pin socket out let 6 Amp point on independent board
M & L Sub main wiring complete with 2 runs of 2.5 Sqmm single core PVC insulated unsheathed cable 1100 V grade with multistranded copper conductor ISI marked drawn throughn and including PVC rigid conduit and conduit accessories fixed on surface/wall celing etc including provision of 1 run of 2.5 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity.
S&F polycarbonate Switch piano flush type,SP, 6 Amps, one way complete all as specified.
S&F socket out let 3 pin , 6 Amps (2 in 1 Multi purpose) flush type controlled by one switch ISI marked make complete all as specified.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20A capacity
Supply and laying tubes, Galvanised,"medium " grade, with all fittings and laid in trenches., all as specified for size:-15 mm bore pipe
Supply and fixing stop valves, cast copper alloy, secrewed down, high pressure with crutch or butter fly handle, fancy type, screwed both ends for iron pipe or for unions and fixed of size 15mm dia bore
S & F flexible hose pipe 25mm dia for drain of water from water cooler all as specified and direced
Supply and fix PVC Connection 15mm dia 450mm long complete all as specified and directed.
M&L PCC 1:2:4 type B-2 with 40 mm graded crushed stone aggregate for capping of plateform for water cooler complete all as directed.
Jain Traders
D S Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .