Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.0 L+₹1.0 L (4.68%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹26.9 L
EMD Value
₹53,800
Closing Date
27 Feb 2021, 6:00 pmClosed
GE JAIPUR
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
PROVN OF TOILET AT SSOI, REAR GATE AT 61 CAV AND TWO WHEELER PARKING NEAR BLDG NO 8 AT ZONE-I UNDER JAIPUR MIL STN
2021_MES_418021_1
GE/J-69/2020-21
Open Tender
Civil Works
Item Rate
180 days
JAIPUR
As per NIT
5 documents required · 5 mandatory
₹500
GE JAIPUR
₹53,800
Yes
30 Mar 2021
2 Feb 2021
1 Mar 2021
2 Feb 2021
27 Feb 2021
15 Feb 2021
2 Feb 2021 - 13 Feb 2021
Amount
Surface excavation not exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil.
Excavating in trenches, n.exc 1.5m wide and n exc 1.5m in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10sq m on plan and n.exc 1.5m in depth and getting out in soft/loose soil
M&L returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soft/loose soil
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point.
Earth filling under floors including spreading, leveling, watering and well ramming in layers not exc 30 cm thick.
M&L hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface all as directed.
M&L cement concrete in foundations filling, sub base and mass concrete 1:4:8 type D-2 using 40mm graded aggregates
M&L reinforced cement concrete M-25 (Design mix) using 20mm graded stone aggregate in foundations including rafts, footings, foundation beams, plinth beams, bases for columns, under reamed piles and mass concrete complete all as directed
M&L reinforced cement concrete M-25 (Design mix) using 20mm graded stone aggregate in columns, pillars, piers, posts, struts and the like.
M&L RCC M-25 (Design mix) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and directed.
M&L for use and waste of rough finish formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete.
M&L for use and waste of rough finish formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished flat surfaces of concrete.
M&L for use and waste of rough finish formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for fair finished flat surfaces of concrete.
M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete.
M&L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n.exc 20cm wide for rough finished surfaces all as specified and directed.
M&L for brick work with sub-class 'B' bricks, straight or curved on plan exc 6m mean radius built in In cement mortar 1:6
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4.
M&L Mild steel bars TMT 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed
All as per item No 18 above but 8mm to 10mm dia.
All as per item No 18 here-in before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders all as specified and directed.
M&L rendering 15mm thick on fair faces of brick work or concrete surface in two layers (5mm thick CM 1:4 over 10mm in CM 1:6) finished even and smooth without using extra cement.
M&L rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonary or on concrrete surfaces finished even & smooth without using extra cement complete all as specified.
M&L rendering 10 mm thick on ceiling surfaces in CM 1:3 finished even and smooth without using extra cement.
M&L for Framed work as in doors or gates of angle or other section as chowkhat., tie bar, hold fast, guard bars cooler stand , purline etc complete,incl drilled for fixing complete
M&L 35mm thick factory made plain, framed, paneled door shutters kiln seasoned and chemically pressure treated second class, hardwood (two panels) with lock rail and panel of 9mm thick BWP commercial marine grade ply wood bonded with high quality liquid phenol formal dehyde synthetic resin adhesive confirming to IS-710. The size of rails and style shall be as per IS-1003. The shutter shall be fitted to chowkhats as directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube as per specification and drawing.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. Tubes for top & bottom rails, MS frame shall be covered with heat moulded lain colour PVC Ç'channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading and jointed together with solvent cement, suppling and fixing in the frame at site as per secification & drawing.
S&F 100mm long mild steel butt hinges, medium weight cold rolled.
S&F 300 mm aluminium alloy anodised sliding door bolt with hasp and staple bolt type and fixing clips of sheet cash or extruded sections and hinges bolt and sliding bolts etc.
Aluminium handles cast type, anodised, 150 mm size complete, all as specified .
S&F 200 mm long Aluminium anodised barrel tower bolt of extruded section
Supply and fixing anodised aluminium window and ventilator shutters, side hung typewithout sash, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium fittings such as peg stays 150mm long 1 No, hinges type B-21, 100mm long (2 No) suitable handle 1 No complete
S & F stainless steel wire cloth 0.36 mm nominal dia of wire & average width of aperture 1.40 mm and fixed with stainless steel wire staples
S & F 5.5mm thick plain sheet glass ordinary quality to aluminium door/ window in sqaures not exc 0.5 sqm in each pane complete
M&L preparation of new steel surfaces of any description over exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified.
M&L for Preparing new wooden surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer
M&L 100 mm thick cement conrete 1:4:8 type D2 (using 40mm grade stone aggregate) as in sub base of floors.
M&L 25 mm thick PCC 1:2:4 type B0 under floor tiles
M&L Non skid coloured joint free ceramic tiles 7mm to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm as in floor set and jointed in neat cement slurry and pointed in coloured cement match the shade of tiles over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M & L glazed coloured joint free ceramic tiles 300x450x7 to 8 mm thick, on vertical surfaces of wall such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10mm thick rendering on stone masonry surfaces or surfaces other than fair faces of brick work in CM 1:4 complete.
M&L 50mm thick, plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregates) as in plinth protection finished even and smooth w/o using extra cement with joints 10mm wide and in full depth at corners and @ 3. m c/c filled with mastic mortar complete all as specified and directed.
M&L preparation of newly plastered surface wall and applying two coats of distemper oil emulsion of any tint over a coat of primer complete all as specified and directed.
M&L preparation of newly plastered surfaces of ceiling & applying three coats of white wash complete all as specified and directed.
M&L preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint complete all as specified & as directed.
S&F GI tubing medium grade with all fitting 15 mm bore fixed to wall or concealed or fitted to ceiling or laid under floor complete all as specified and directed.
S&F GI tubing medium grade with all fitting 20 mm bore fixed to wall or concealed or fitted to ceiling or laid under floor
S&F Stop valves cast copper alloy screwed down high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions in 20 mm bore .
S&F 15 mm bore bib cock, two way, cast copper alloy chromium plated, fancy type with capstan head, screwed down, screwed for iron pipe or for brass ferrule as per Jaquar Cat Part No KUB-35014F or equivalent and approved by GE
S&F in repair PVC valveless, syphonic action type, flushing cistern, low level,10 ltr capacity, white, with intel, ball valve, float and handle including brackets,flushing pipe complete all as specified & directed.
S&F cromium plated brass hand shower (health faucet) with 8mm dia 1.00m long flexible tube and wall hook as per Jaquar cat Part No ALD-573 or equivalent and approved by GE
S&F cromium plated brass soap dispenser automatic capacity 0.8L of aluminium/ABS materials crome/black finish complete as per Jaquar Cat part No SDR-BLC-D50160AS or equivalent and approved by GE
S&F Hand dryer stainless steel of stain finish complete as per jaquar Cat part No HDR-SAP-M-99 ACS or equivalent and approved by GE
S&F Toilet paper roll holder with flap Vitreous china with CP brass screw
S& F PVC connections 15mm size with PTMT nuts of length 600mm
S & F 15 mm bore CP Pillar cock 135 mm extension body (Quarter turn).
S&F vitreous china Pedestal pattern EWC s trap white bowl size 775mm x360mm x660 mm including dualflush fitting and cistern and including soft close seat cover as per Jaquar ct part No CNS-WHT- WS-11, CNS- WHT- WCF-1 (Dual Flush Fttings), CHS-WHT-CSO-1 (Cistern), CNS-WHT -WCS-! (Soft close seat cover) or equivalent and approved by GE
S&F vitreous China urinals, bowl type (back or corner wall type) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement, Make - Hindware Cat Part No -96008 or equivalent and approved by GE
S&F Angle stop valve cast copper alloy , chromium plated screwed for iron pipe, 15mm bore.
S & F 1000 Ltrs capacity rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) hoisted and fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc complete all as specified in SSR Part I,
S & F Ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20mm dia (minimum weight 210 gms) complete,
S & F vitreous china wash basin, white flat back size 550 x 400 mm excluding taps, waste chain and plug and porcelain stopper but including brackets, CP coupling , PVC waste pipe complete.
M&L for Granite (of any tpe), 16 to 18mm mm work (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
M&L Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
S&F stainless steel grating doom 100mm dia all as directed.
S&F 100 mm bore Cast iron soil, waste and vent pipe in any length with or without ears, with cement Joints, laid in trenches or but fixed in walls
S&F Bends for 100 mm bore pipe with ducks foot or heel rest for cast iron pipe fitting
S&F cast iron cowls for 100 bore pipe
S&F stack clamps out of 50 mm by 5mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall for 100 mm bore pipe.
S&F 100 mm cast iron sanitary connection socket to fit WC outlet
M&L precast RCC 1:2:4 type B-1, using 20mm graded stone aggregate for manhole cover including placing over manhole all as specified including demolition of old RCC manhole covers. Note :- Reinforcement shall be measured and paid separately.
S&F framed bracket of flat iron around manhole cover of any size, cut to shape welded, riveted etc complete all as specified
Cutting into existing manholes/ septic tank for connecting new drains making good to pipe and rendering , cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 section) in cement concrete 1:2:4, type B-1, smooth finished and reforming benching as required for 200mm bore pipe
M & L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, with grey cement and pigment, laid over and including 25mm thick sand cushion layer complete
M & L PCC blocks or slabs 150 mm thick (1:2:4) mix type B-1 using 20 mm graded aggregated with plain or interlocking joints as directed complete in walls setting in CM (1:6).
S & F brass chromium plated tubular towel rail 20mm dia, D type, 60cm long between flanges
S&F Looking mirror 6mm thick bevelled edge , size 0.75mm x 1.80M fitted with distance pieces( 4Nos ) of stainless steel including making holes in mirror, fixing arrangement as directed
M&L padding in PCC 1:2:4 type B-0 (using 12.5mm size graded stone aggregates) laid to average consolidated thickness of 50mm to a required slope finished even and smooth without using extra cement.
M&L screed bed or bedding layer or mortar 15mm thick over roof finishes in CM 1:6 finished even and smooth w/o using extra cement.
M&L for preparation of new surface of any description over 10cm width or girth and applying one coat of aluminium paint over top of APP menbance
M&L painted cement plastered surfaces with one coat of cold applied bituminous primer @ 0.40 ltr/Sqm conforming to IS-3384 and laying APP based polymeric membrane not less than 3mm thick, weighing not less than 3.5kg/sqm, reinforced with polyester non woven fabric (weighing not less than 150gms/sqm) shall only be used. It shall be laid by torch application. Side over laps shall be 75mm and the end lap shall be 100mm and all over laps and joints shall be sealed by torch application. For parapets, membrane shall be taken to a height of minimum 60cm and then inserted inside the parapet groove. This shall be finished by a membrane flashing.
M&L preparation of new steel surfaces of any description over exc 10cm in width or girth and applying two coats of synthetic enamel paint complete all as specified.
Excavating in post holes (or similar holes) each not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exceeding 50m and making good surface
M&L Cement concrete in foundations, filling and mass-concrete in PCC (1:2:4) type B-2 using 40 mm graded stone aggregate
M&L for MS rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Gde Fe 410 (W) (Gde E-250)
S&F of pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
M&L Pre-cast cement concrete block masonry with solid blocks, exceeding 10 cm in width and setting in mortar complete
M&L reinforced cement concrete (nominal mix) type B1, 1:2:4 (20mm graded aggregate) as in foundation including rafts footin gs, foundation beams plinth beams, bases for columns etc basement slabs, under -reamed piles and mass concrete.
M&L reinforced cement concrete (nominal mix) type B1, 1:2:4 (20mm graded aggregate) as in columns, pillars piers, postes and struts etc
Use and waste formwork to sides of concrete foundation,footings, bases of columns reft and matt beams sides and soffits (if any) of foundations and plinth beams and similar work vertical or to
Use and waste formwork to sides of pillars, posts struts piers, columns and stanrchions for fair finished surface of concrete square.
M&L for Granite (of any tpe), 25mm thick work (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite
M&L rendering 15mm thick on stone other than fair faces of brick surfaces in CM 1:4 surface finished even and smooth without extra cement.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into concealed conduit and terminated for mounting modular cover plate & frame, switches, sockets, fan regulators as required for one light point controlled by one switch.
All as per item No. 92 here-in-before but one fan point controlled by one switch.
All as per item No. 92 here-in-before but one socket outlet 6 amp controlled by one switch on the same board with other switches.
All as per item No. 92 here-in-before but one socket outlet 6 amp controlled by one switch on indepdendent board.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 sqmm (Green) drawn into into existing concealed conduit and terminated in modular metal flush boxes for mounting modular cover plate & frame for one socket point 16 Amps controlled by one switch.
S&F switch modular 1 way 6 Amps, 230 volts, 1 module
S&F modular socket 6 Amps, 2/3 pin combined 2 module AC 230 volts
S&F modular switch 1 way 16 Amps, 230 volts, 1 module.
S&F modular socket 6/16 Amps, 2/3pin combined 2 module AC 230 volts.
S & F modular blanking plate 1 module
S&F modular whiter cover plate with frame 1/2 module.
S&F modular whiter cover plate with frame 3 module.
S&F modular whiter cover plate with frame 4 module.
S&F modular whiter cover plate with frame 6 module.
S&F modular whiter cover plate with frame 8 module.
S&F Modular metal flush box 1/2 module
S&F Modular metal flush box 3 module
S&F Modular metal flush box 4 module
S&F Modular metal flush box 6 module
S&F ceiling rose 3 plates polycarbonate body complete.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43, IK-09 with reversible double door, recess mounted , having insulated 100 Amps tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 volts, 8 ways.
S&F MCBs of 'C' series single pole 6 to 32 Amps having breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs complete. Make : Legrand Cat Ref No. 508587 to 408595 or equivalent in Hager/Schneider as approved
All as per item No. 114 above but double pole 40 to 63 Amps. Make : Legrand Cat Ref No. 408631 to to 408636 or equivalent in Hager/Schneider as approved
S&F LED bulk head fitting 9 watt IP 66 & IK 09 with pressure die cast aluminium housing & polycarbonate diffuser duly pre wired connection with 0.75 Sqmm PVC insulated & sheathed three core flexible multi stranded copper conductor cable all as per Philips Cat Ref No. WT 202W LED 6S PSU S2 PC or equivalent as approved by GE.
S&F LED batten (1.2M) made of CRCA sheet housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 125 lumen per watt and total power consumption not more than 16 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD<10% and PF>0.95 complete. Make : Philips Cat Ref No. Endura Next Batten "BN 308C LED 20S -6500 L 60 PSU WH" , CG/ Bajaj or equivalent as approved by GE
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core.
Sand cushioning to the under ground electric cable complete all as specified considering 19.75 of SSR part -I
S&F steel tubes 40 mm bore light grade ISI marked with medium grade fittings for cable protection as required.
M/L Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified
Supply and fix PVC fresh air fan 200/250 mm sweep with louvers, fan motor and accessories complete including making connections.
M&L for earthing with galvanized steel earth plate electrode 600mmx 600mmx6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with the top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth lead wire 4mm dia by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate No. 03 of SSR Part -I connected to earthing point and including 15mm bore light grade G.I. protection pipe (upto 7.5 mtr from edge of the pit), PCC pit in mix 1:3:6 type C1 with PCC 1:2:4 type B-1, 40mm thick cover, watering arrangement with funnel and wire mesh and 20mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earh work including testing on completion.
S&F LED mirror light 11 watts 6500K having lumen output 1000. Make Philips cat part No. 31167 or equivalent as approved by GE
S&F LED fixture 10 watt having lumen output 100 lumens per watt including connection.
S.R.Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .