Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹24.8 L
EMD Value
₹25,000
Closing Date
23 Feb 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DE(NH)Gobi
O/o the Divisional Engineer National Highways,Ram nagar, 2ndstreet,VeerapandiVillage,Gobichettipalayam638452
Providing Short term Road safety measures of accident prone areas located at I) Km 74/10, 75/8, 77/2 77/6 from Barliar to Nandagopal bridge (Km 63/2 - 78/0).
2026_MoRTH_895511_1
TNNo15/25-26/DO/Dt.23.1.26
Open Tender
Civil Works
Percentage
90 days
Gudalur
Refer document
3 documents required · 3 mandatory
₹7,080
6000 online payment through bharatkosh webportal
₹25,000
24 Jan 2026
24 Jan 2026
24 Feb 2026
24 Jan 2026
23 Feb 2026
24 Jan 2026
Painting two coats after filling the surface with plastic emulsion paint in all shades on new plastered concrete surfaces
Providing and laying of Hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 250 gms per sqm area, Thickmess of 2.5mm tk is exclusive of surface applied glass beads as per IRC 35.The finished surface to be level uniform and free from streaks and holes etc complete as per MORT & H specification no 803.
Providing and fixing reflective road studs of 'category A' raised pavement markers made out of polycorbonate and ABS /methyl methercrylate/ABS moulded body confirming to ASTM D788 and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values conforming to ASTM D 4280.The reflective raised pavement marker shall also confirm to the MORTH circular No RW/NH/33023/10-97- DO III, dt: 11.06.1997. The height of the marker shall not exceed 15mm, 90mm and 100mm and either minimum reflective area of 13sq.cm on each side and the slope to the base shall preferably be 35+/- 5 degree.Each reflector shall have a CIL not less than values specified in Table 2 of said MORTH circular.The strength of detachment of the integrated cylindrical shanks ( of dia less than 19+/- 2 mm and height not less than 30+/- 2mm ) from the body is to be a minimum value of 600Km. fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer's recommendation as complete as directed by the engineer.The marker shall support a load of 13635kg tested in accordance with ASTM D4280and confirming to IRC 35-2015 guidelines and MORT & H specification No 804 etc complete.
Providing and erecting directional and place identification retro reflectorised sign made out of High Intensity prismatic grade sheeting conforming to type IV standards as per IRC 67 - 2022 and ASTM D 4956-09, Specification and fixed over 2mm thick aluminium sheet fixed over a back supporting frame of 25mm x 25mm x3mm mild steel angle and supported on a mild steel angle 75mmx 75mmmx 6mm with a clear height of not less than 2.10m rom the ground level to the bottom of the sign board and 0.60m below ground level.The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means of proprely designed conveyance of all material, equipment, Machinaery and labour with all leads and lifts, loading chargenecessary for satisfactory completion of the work as directed by the engineer reflection as per Table 6.6 of IRC 67-2022.The retro reflective sheeting shall be covered under 7 year warranty issued for field preformance and a certified copy o f three years outdoor exposure report shall be obtained as per IRC 67-2022(as per MORT&H specification No.801)(Signboard made of retro reflective TYPE IV sheeting ,astm D 4956 specification more than 0.90 sqm))
Providing and erecting of retro- reflectorised hazard marker traffic sign made out of High intensity prismatic grade sheeting conforming to type-IV standards of IRC -67 : 2022 and ASTM D 4956-09,Specification and fixed over 2mm thick aluminium sheet fixed over a back supporting frame of 25mmx25mmx3mm mild steel angle and supported on a mild steel angle post 75mmmx75mmx6mm an d060m below ground level.The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means oof properly designed foundation M15 grade cement concrete 45cmx45cmx60cm size including cost and conveyance of all materials,equipment,machinary and labour with all leads an dlifts, loading charges necessary for satisfactory completion of the work as directed by the engineer in charge. High intensity retro-reflectro sheet shall consist of minimum coefficenet of retro reflection as per table 6.6 of IRC 67-2022.The retro reflective sheeting shall be covered under 7 year warranty issued for field performeance and a certified copy of three years outdoor exposure report shall be obtained as per IRC67:2022(as per MORT & H specification No 801) 30cm x 90cm rectangular
Providing and fixing of rectro refletorized cautionery mantatory sign and informatory sign (without definition board) made out of high intensity prismatic Grade sheeting conforming to IRC 67 - 2022 and ASTM D 4956 - 09, Type IV specification and fixed over 2mm thick aluminium sheet fixed on back supporting frame of 25mm x 25mm x 3mm Mild steel angle and supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm ; 60 cm below ground level etc.., complete The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means of properly desigmed foundation with M15 grade cement concrete 45cm X 45cm X 60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer in charge.High intensity Retro-Reflectro sheet shall consist of minimum coefficient of retro-Reflction as per Table 6.6 of IRC 67-2022.The retro-reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67-2022(as per MORTH specification no 801) (without definiton board) (60cm circular board)
Providing and fixing of rectro refletorized cautionery mantatory sign and informatory sign ( without definition board) made out of high intensity prismatic Grade sheeting conforming to IRC 67 - 2022 and ASTM D 4956 - 09, Type IV specification and fixed over 2mm thick aluminium sheet fixed on back supporting frame of 25mm x 25mm x 3mm Mild steel angle and supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm ; 60 cm below ground level etc.., complete The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means of properly desigmed foundation with M15 grade cement concrete 45cm X 45cm X 60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer in charge.High intensity Retro-Reflectro sheet shall consist of minimum coefficient of retro-Reflction as per Table 6.6 of IRC 67-2022.The retro-reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67-2022(as per MORTH specification no 801) (without definiton board) 90 cm Equilateral Triangle
Providing and fixing of rectro refletorized cautionery mantatory sign and informatory sign ( without definition board) made out of high intensity prismatic Grade sheeting conforming to IRC 67 - 2010 and ASTM D 4956 - 09, Type IV specification and fixed over 2mm thick aluminium sheet fixed on back supporting frame of 25mm x 25mm x 3mm Mild steel angle and supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm ; 60 cm below ground level etc.., complete The sign post should be painted as per IRC 67-2022 and firmly fixed to the ground by means of properly desigmed foundation with M15 grade cement concrete 45cm X 45cm X 60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer in charge.High intensity Retro-Reflectro sheet shall consist of minimum coefficient of retro-Reflction as per Table 6.6 of IRC 67-2022.The retro-reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67-2022(as per MORTH specification no 801) (without definiton board) 60cm x 45cm chevron board
Calculation of SubTotal, GST and Total carried out by system automatically
Sub Total Amount for above all items (excluding GST)
GST 18% for above SubTotal Amount
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
TENDERDOCUMENT.pdf
Tender Documents • 0.19 MB
BOQ_941251.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .