Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹47.5 L+₹2.4 L (5.35%)Rejected-Finance GROUND FLOOR SUIT NO 2 SARITA APARTMENT KHARIDA MAIN ROAD KHARAGPUR 721 301 DIST PASCHIM MIDNAPORE WEST BENGAL | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721301 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | Rejected-Technical KHEMASULI P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPUR WEST BENGAL | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | - | Rejected-Technical Rejected, not having c(vi) Category | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected, NO in WLR | |
| 5 | Rejected-Technical 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | - | Rejected-Technical Rejected, not having c(vi) Category |
Tender Value
₹43.7 L
EMD Value
₹87,320
Closing Date
16 May 2025, 6:00 pmClosed
Major MK Yadav, GE
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
PROVN OF CENTRALIZED FIRE ALARM AND SMOKE DETECTION IN REFUELLING AT AIR FORCE STATION KALAIKUNDA
2025_MES_704566_1
C/8113/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN KALAIKUNDA
Class D Category c(vi)
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹87,320
Yes
29 Jul 2025
18 Apr 2025
17 May 2025
18 Apr 2025
16 May 2025
2 May 2025
Amount
Supply and fixing of Microprocessor based multi-loop , true peer-to-peer networkable adressable fire alarm control panel with minimum 80 character LCD display, 4000 event plus alarm log history events, QWERTY keypad for programming . The panel should be equiped with sufficient numbers of loops considering 20% spare capacity in each loop . Each loop shall have a capacity of minimum 300 analog addressable devices . The panel shall work in degrade mode in case of CPU failure. Four access levels , flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition . Designed to meet UL864, 10th edition & FM approved including 8 multicriteria detector , MCP-4 Nos , hooter strobe 4 nos complete all as specified and directed . NOTE :- 24 Volts batteries of suitable capacity shall deemed to be inclusive in the quoted rate.
Supply and fix GSM auto dialer unit for communication purpose suitable for fire alarm panel complete all as specified and directed.
Supply and fix sealed probe type heat detector with PESO approved expulsion proof enclosure 65 degree celsius temperature setting including monitor module complete all as specified and as directed .
Supply and fix addressable manual call point break glass type , flame proof , weather proof suitable class IIA/IIB application , PESO approved including mointor module and all other required mounting accessories complete all as specified and as directed .
Supply and fixing conventional flame proof , weather proof minimum 90DB sounder with strobe suitable for class IIA/IIB lication , PESO approved including monitor module and all other required mounting accessories complete all as specified and as directed .
Supply & fix addressable control/relay module ,Module shall provide supervised NAC output rated at 24V DC , 2A or potential free contact . Device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the devices and adressing shall be with user friendly rotary decimal switches complete all as specified and as directed .
Supply & fix addressable monitor module for sprinklers, panic inputs bars& other third party inputs. The monitor module shall monitor potential free contacts and the device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the devicesand adressing shall be with user friendly rotary decimal switchs complete all as specified and as directed .
Supply and fix Isolators module for isolating short/dewired/loose circuits with automatic resetting arrangement,with provision of isolators base . The device shall be have an LED which shall blinkin normal state & get steady on activation to monitor the health status of the device and module shall be supplied with mounting plate from OEM for ease of Installation and maintenance complete all as specified and as directed .
Supply and fix Flameproof outdoor horizontal double mounting three phase 400/440 V , 2800 RPM 50 Cycle per seconds flame proof motorised siren 3.5 KM range along with control panel complete all as specified and as directed .
Supply and fixing 1.5 Sqmm , 2 core FRLS rated armoured cable including all necessary fixing accessories for the FAS loop cable, red colour complete all as specified and as directed .
Supply and install UPS 1KVA for fire alarm control panel complete all as specified and as directed .
Labour only for connecting ,testing and commissioning all spares of fire alram system including submission of layout plan of fire alram system of entire Refuelling section by deploying One Service Engineer, One Electrician and two helper complete all as specified and as directed . Note : (i) For Item Srl No. 1 to 13 , all items to be executed through OEM or OEM certified agencies as approved by GE and as per OEM recommendation and OEM authorisation certificate to be submited to the dept before commencement of work . (ii) Complete layout plan for installation of fire alarm system is to be submited to the dept as mentioned in Item srl 13 .
Lotas Engineers (BID ID -3298598)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .