Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC | ₹32.6 L Quoted ₹33.3 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹38.9 L+₹5.6 L (16.7%)Rejected-AOC 3838 2ND FLOOR SECTOR 46 C CHANDIGARH UT 160047 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160047 | ₹38.9 L+₹5.6 L (16.7%) | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| 3 | L3₹41.4 L+₹8.0 L (24.1%)Rejected-AOC | ₹41.4 L+₹8.0 L (24.1%) | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| 4 | L4₹43.1 L+₹9.8 L (29.4%)Rejected-AOC | ₹43.1 L+₹9.8 L (29.4%) | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER |
| 5 | L5₹44.9 L+₹11.6 L (34.7%)Rejected-AOC | ₹44.9 L+₹11.6 L (34.7%) | L5 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
26 Jul 2022, 6:00 pmClosed
RAHUL MEENA IDSE EE
MES OFFICE GE KASAULI DISTT SOLAN HP
REPAIRS, RENEWAL, REPLACEMENT OF LT PANELS, LT UG CABLES, SECURITY LIGHT, STREET LIGHTS, JUNCTION BOX, STREET LIGHT TIMER AND CERTAIN OTHER WORKS AT SUBATHU UNDER GE KASAULI
2022_MES_533975_1
GEK-26/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SUBATHU UNDER GE KASAULI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KASAULI
₹88,000
Yes
7 Sept 2022
27 Jun 2022
2 Aug 2022
27 Jun 2022
26 Jul 2022
11 Jul 2022
Amount
Schedule 'A' Section - I
Taking down old UNSV ACSR conductor, any type and size from the poles and supply and fixing new ACSR conductor including stringing on LT poles complete including aluminium binding wires, jumpering, bindings at insulators etc, complete, all as specified and directed.
Dismantling old unsv and S&F Stay assembly complete with accessories as shown in electrical plate No-1 (loop type insulator, stay clamps, excavation and concrete measured separately) with stay rod 16mm dia, MS plate 6mm thick size 230x230mm, complete, all as specified and directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red color and fixed with MS clamps , bolts and nuts of approved size, for LT 20x15mm size.
M&L for anti-climbing device, spikes type fabricated out of MS bars (round,square and flat) including nuts,bolts,washer and welding in two halves made to shape to suit the cross section of the pole.
S&F Loop type insulator, vitreous porcelain white , brown, green small size with overall dimensions 65mm x 90mm clearance of hole 16mm, complete, all as specified and directed.
S&F in replacement of Galvanized stay strand, size 7/4mm, incl taking down the old unserviceable stay wire, complete, all as specified and directed.
Supply & Fixing and replacement Aluminium Thimbles/Lugs in existing panel and DB box in verious sizes 10/16/25/35/50/70/95/120/150/220/240/300/400/630sqmm. NOTE:- “Qty of each size of thimbles will be as directed by Engineer-in-Charge”.
Supply and fix in replacement to existing 1x18 Watt CFL post top light fitting with Decorative LED Post Top Lantern with transparent difuser of cap 30/20 Watt complete all as specified and directed by Engr-in-Charge.
S & Fin replacement LED Building security light 30 watt pressure die cast housing with individuals LEDs & Lens with modular secondary optics and IP65 protection with electronics driver and copper conductor 3 core of 0.7 sqmm from ceiling rose to security light.
S & F LED flood light 60/70 watt Pressure die cast housing with IP 66 protection Efficient high output emitter LED for better distribution incl electronics driver & connection with copper flexible cable 3 core complete all as specified and directed.
S & F in replacement LED type flood lights 200 watt ,Minimum 20000 lumens with IP 66 protection. highly efficient LED flood light with lens made of pressure die cast aluminium housing with anodised Al reflector & enclosed with thoughened glass with electronic driver incl connection with 3 core 1.5 sqmm .copper conductor from junction box.
S &F in replacement of Battery 12 volt 180 AH maintenance free battery all as directed by EIC.
S &F in replacement of Battery 12 volt 40 AH maintenance free battery for solor street light all as directed by EIC.
Supplying & fixing in replacement of clamps made out of 40x6 mm bending to shape, drilling holes for bolts suitable for fixing GI pipe bracket to steel pole, made in two halves, including nuts, bolts, washers and painting with two coats of aluminium paint over a coat of red oxide primer, complete, all as specified and directed.
S&F Steel water tubing, light grade, galvanised (ISI marked), 80 mm bore with all fittings, laid in trenches/ under roads or fixed to poles for passing cables for protection of cables, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 25 Sqmm 3.5 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 25 Sqmm 4 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 16 Sqmm 4 core, complete, all as specified and directed.
Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 10 Sqmm 2 core, complete, all as specified and directed.
Supply, laying, testing and commissioning of cable LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4 core confirming to IS specification including taking out existing unserviceable cable complete all as specified and as directed.
Supply, laying, testing and commissioning of cable LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 sq. Mm 3.5 core confirming to IS specification including taking out existing unserviceable cable complete all as specified and as directed.
Supply, laying, testing and commissioning of cable LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 sq. Mm 3.5 core confirming to IS specification including taking out existing unserviceable cable complete all as specified and as directed.
Streching of loose ACSR conductor including jumpering, binding,etc all as required in LT OH line, complete, all as directed. Note:- Disconnecting the existing security light or cable connection before stringing and reconnecting after stringing is included in the rates quoted.
Supply only transformer oil (ISI marked) tested upto 50 KV.
Supplying & fixing in replacement of GI wire as earth wire of size 4mm dia as required at site complete all specified and directed.
Supplying & fixing in replacement of connection/Junction box made out of 1.6mm thick MS sheet front openable, weather & vermin proof including painting two coats of synthetic enamel paint over a coat of red primer. Connection box shall be suitable for housing & including aluminium bus bar 25 Amps cap - 2 Nos, MCB SP 6 Amps- 01 No and having provision of cable hole in bottom for two to three cables of size 16 Sqmm 4 core armoured cable connection box shall be fitted on street light pole and fixing arrangements i.e. MS clamps etc deemed to be provided by the contractor, size of box - 200 x 150 x 100mm, complete, all as directed.
Supply & fixing in repair junction box from LT electric poles and Supply and fixing Junction box of size 168 x 253 x 115 outdoor type, weather proof, factory made out of PVC sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and out going cable / wire complete comprising with the followings :- (a) Bus bar with two aluminium strips 100Amps capacity insulated with insulators, incl colour coding , including control wiring from bus bar to MCB (b) MCB SP 6Amps - 01 No. (c) clamp made out of 25mm x 3mm flat iron duly welded with nuts & bolts complete all as specified and directed.
Supplying & fixing in replacement of double walled corrugated HDPE duct pipe of 100 mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittinggs for cable protection complete all as specified and direcetd.
Double walled corrugated HDPE duct pipe of 63 mm inner dia confirming to IS:14930 (Part-II) of approved colour with fittings for cable protection complete all as directed.
Supplying & fixing in replacement of non metallic rigid PVC conduit medium grade 20 mm dia ISI marked to be fixed on pole with all fittings including mouth pieces for passing of sub main wiring, complete, all as directed.
M&L Cable PVC insulated PVC unsheathed un-armoured copper conductor (multi stranded) of cross sectional area 2.5 sqmm 2 core all as required for connections to light fittings, complete, all as directed.
M&L for fuse barrel assy upto 25 Amp, ISI marked complete, all as specified and directed.
M&L for Painting of steel tubular pole 9.0 metre long, by applying two coat of aluminium paint after scraping / brushing and cleaning the rust on pole and cross arms. Aluminium painting will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and yellow enameled paint (30 Cms each). Pole Nos will be written on pole by black paint in white circle of 150mm dia, complete, all as specified and directed. Note:- Only one coat will be applied at one time and payment at 50% of coated rate to be applied at the first time of first coat. Second coat is to be done more than 30 days after first coat.
Excavation in trenches in hard / dense soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth, for foundations, laying of pipes etc and not exceeding 10Sqm on plan for manholes etc and not exceeding 1.5 metre in depth and getting out in any type of soil, complete, all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth and getting out in soft disintegrated rock (considered for road cutting)
Returning, filling in including spreading, leveling, watering and well raming excavated soid in layers not exceeding 25 cm thick, filling back in trenches after cables have been laid and tested, poles, stays, struts have been erected and tested complete all as specified.
Removing excavated material (soils) to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5 metre above the starting point, complete, all as specified and directed.
Supply and Laying reiforced precast cable cover class LV Type I flat size 250mmmx 150mm x40 mm for the protection of cable laid flat dry across the cable complete all as specified.
Supply and fixing and replacement power contractor 4 Pole 415 volt AC1 rating 400 Amp incl neseccary electrical connection as per directed by the Engineer-in-charge .
M&L for renewal of Earthling of poles/system with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried vertically in ground not less than 2.25 metres below ground level with top edge of the plate not less than1.5 mtr below ground level, connected to GI strip 32x6mm by means of nuts,bolts and washers and encased in and inclduing 40mm dia GI light grade pipe upto 2.4 mtr height from ground level fixed by MS flat iron clamp 40mmx5mm with nut , bolt and washers. GI strip fixed to base along pole and connected to exisiting system with alternate layers of charcoal dust, salt packed around plate 150mm thick including watering GI pipe, medium grade 20mm dia, 1.5mtr ling fixed to funnel with wire mesh complete with PCC chamber and RCC chamber cover all as Electrical plate No. 3 SSR part I-2009 including excavation and earth work in any type of starta and testing on completion. (Note:- GI strip and GI pipe beyond 7.5M long shall be measured and paid separately)
Supply and fix in replacement of sheet metal enclosure, Triple pole and neutral AC, 415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection including provision of four pole 100 Amp isolator and MCBs of cap 20 to 40 Amps as incomer with metal double door and flush to wall including all cutting etc on wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces complete all as directed by Engineer - in - Charge.
Supply & fix in replacement of Isolator 4 Pole 'C' series 630 amps capacity AC 415 V,10kA complete all as specified and directed.
Supply and fix in replacement of MCCB 4 pole 400 Amps 36 KA capacity AC 415 v complete all as specified and directed.
Supply and fix in replacement of MCCB 4 pole 200 Amps 36 KA capacity AC 415 v complete all as specified and directed. .
Supply and fix in replacement of MCCB 4 pole 160 Amps 36 KA capacity AC 415 v complete all as specified and directed.
Supply and fix in replacement of MCCB 4 pole 100 Amps 25 KA capacity AC 415 v complete all as specified and directed
M&L for MCCB 250 Amp , 4 pole 415 Volts, rupturing capacity 36 KA Adj thermal fixed magnetic MCCB including fixing arrangements complete and taking out old MCCB all as per directed by Eng- in -charge
M&L for MCCB FP,160 A rupturing capacity 36 kA with adjustable Thermal Magnetic Based Release (O/C & S/C Protection) MCCB including fixing arrangements complete and taking out old MCCB all as per directed by Eng- in -charge
M&L for MCCB 100 Amp , 4 pole 415 Volts, rupturing capacity 16 KA Adj thermal fixed magnetic MCCB including fixing arrangements complete and taking out old MCCB all as per directed by Eng- in -charge
M&L for MCCB 63 Amp , 4 pole 415 Volts, rupturing capacity 16 KA Adj thermal fixed magnetic MCCB including fixing arrangements complete and taking out old MCCB all as per directed by Eng- in -charge
Supply and fix in replacement of Renewing tiles in patches, area n exc 5 sq.m. including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles complete complete all as specified and directed.
Supply & fixing PVC 4 line phase separator as per IS standard.
Supply & fixing PVC 3line phase separator as per IS standard.
Supply and fixing and replacement GI pipe, light grade 50 mm bore, ISI Marked for protection to cable along the pole/across road crossing/passing through culvert complete all as specified.
Supply and fixing in repairs straight through (Heat shrinkable) joint kit suitable for 1.1 KV UG XLPE cable of size 70 to 150 Sqmm 3.5 core.
Supply and fixing in repairs straight through (Heat shrinkable) joint kit suitable for 1.1 KV UG XLPE cable of size 185 to 300 Sqmm 3.5 core.
Supply and fixing in repairs straight through (Heat shrinkable) joint kit suitable for 1.1 KV UG XLPE cable of size 400 Sqmm 3.5 core.
Supply and fixing in repairs indoor termination (Heat shrinkable) joint kit suitable for 1.1 KV UG XLPE cable of size 630 Sqmm 3.5 core.
Supply & fixing and replacement Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground
Supply & Laying synthetic rubber mat 2.5mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006 Suitable for electrical shock safety of size 2 mtr x 1 mtr x 2mm thickness ,
Dismantaling exixting old and unserviceable security light brackets and Supply & Fixing Bracket made out of GI light grade pipe of 32 mm dia 1.5 mtr long bend to an angle of 120 degree with 02 Nos MS clamp 25mm x 4mm and 04 sets of nuts,bolts and washers including painting with two coats of synthetic enamel paint over a red oxide primer complete all as specified & directed.
Supply & fixing wiring for circuit/submain wiring alongwith earth wire with the size 2x1.5 sq. mm + 1x1.0 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable from junction box to light fitting.
Taking down old street light fitting and supply & fixing LED type street light fitting 60 watt ,Pressure die cast aluminum housing Heat resistance toughened glass. IP 66 protection with lens & Better optics for uniform distribution with electronic driver incl connection with 3 core 1.5 sqmm .copper conductor from junction box / over head line
Taking out old unsv and S&F LED street light 35/45 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed.
Taking out old unsv and S&F LED street light 90 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade 20mm dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed.
S&F Time switch astro type 110 - 240 VAC 3 Phase - 4W 3 Channel, Base/DIN, 240 volt 16 amp rating with contactor 4 pole 415 Volts 63 Amp 01 No, MCB SP , 240 volts 0.5 Amp 01 No and MCB FP, 415 volts 10 Amp 01 No, fixed in cpri approved sheet metal enclosure 2 mm thick of size 40x40x10 cm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and fixing arrangements by means of 25 mm x 3 mm MS flat clamps, nuts, bolts and washers complete all as specified and directed by Engr-in-charge.
Taking down old unserviceable LED street light fitting of any size/capacity from exsting location i.e from LT pole/Bldg /Store etc and opening up and removing old unserviceable LED Driver /Surge protection device and fixing new driver /SPD and replaceing connection if required to making the street light is serviceable connection and re- fixing the same on existing location (Note:-LED Driver/SPD will be measured and paid seprately)
S&F in repair LED current driver adopter AC 85-265V to DC 24-38 V IP 65 waterproof LED Street light capacity 45 W
S&F in repair LED current driver adopter AC 85-265V to DC 24-38 V IP 65 waterproof LED Street light capacity 60 W
S&F in repair LED current driver adopter AC 85-265V to DC 24-38 V IP 65 waterproof LED Street light capacity 90 W
S&F in repair on existing location including taking out of existing LED Street light surge protection device for additional protectionof following capacity :- 30w,45w,60W,90W
M&L PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation of electric poles, struts PCC blocks and fair finish to exposed surfaces without using extra cement etc complete all as specified.
M&L PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of electric poles, struts PCC blocks and fair finish to exposed surfaces without using extra cement etc complete all as specified.
PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of new pole , including necessary form work complete all as specified and directed
Amount of credit of Rs.74685.40 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
naina devi constructions
Vasudeva Trading Co.
Ayushmat Contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .