Loading…
Loading…
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
1 Oct 2026, 6:00 pm
GE (AF) HASIMARA
GE (AF) HASIMARA PO-HASIMARA DIST-ALIPURDUAR PIN-735215
PROVN OF ANTI SUICIDE FAN RODS IN SMQs/OMQs AND ALLIED B/R WORKS SERVICES AT AFS HASI MARA
2026_MES_787361_1
C/8128/2026-27/E8
Open Tender
Civil Works
Item Rate
210 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹80,000
Yes
1 Sept 2026
1 Sept 2026
8 Oct 2026
1 Sept 2026
1 Oct 2026
24 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S&F stainless steel plate rack of size 24" x 30" x 10", made of 0.50mm thick (min) standard quality steel (SS-204) weight not less than 6 kg, fixed with brass screw, complete all as specified and directed. | 150 | Each | - | - |
| 2 | M&L for 4mm thick pre-painted E-fibre board, designer/decorative, fixed with and including GI snap grid frame size 605mm x 605mm work for false ceiling hangers with 3mm to 4mm dia. G.I. (length as required) adjusting level, fixed to roof slabs/truss by means of ceiling cleats made out of G.I. flat 40 x 3mm size 60mm long and expansion hold fasteners, 12.5mm dia, 40mm long including necessary dismentaling of existing unserviceable ceiling boards of any thickness including cover fillets, complete all as specified and directed. | 250 | Sqm | - | - |
| 3 | Taking down cement plaster of any description any thickness incl racking out joints hacking for keys scrubbing down with water etc, including disposal of debris and rubbish off the premises, complete all as specified and directed. | 730 | Sqm | - | - |
| 4 | M&L 15mm thick rendering in CM (1:6) on other than fair faces of brick work or concrete surfaces of wall, finished even and smooth without using extra cement, complete all as specified and directed. | 730 | Sqm | - | - |
| 5 | M&L for preparation of newly plastered wall surfaces and applying two coats of oil bound distemper over and including a coat of 1mm thick wall care putty and rubbing the surfaces with sand paper to obtain smooth finished surfaces, complete all as specified and directed. | 730 | Sqm | - | - |
| 6 | M & L for complete removal of existing treatment of wall surfaces applying 1mm thick wall care putty and rubbing the surfaces with sand paper to obtain smooth finished surfaces including making good any undulations on the surfaces and applying two coats of oil bound distemper over the putty surface, complete all as specified and directed. | 900 | Sqm | - | - |
| 7 | M&L for preparation of old plastered surfaces of wall and applying one coat of oil bound distemper approved tint, complete all as specified and directed. | 1,500 | Sqm | - | - |
| 8 | Supply and installation of Anti Suicide Fan Down Rod (smart fan rod), length 300mm (12"), white MS pipe heavy duty zinc plated and powder coated, 19mm outer dia, 1.8mm (+ 0.05mm) wall thickness including in-built spring set and with a built-in paire FR connector copper wire of suitable cross section, spring set shall be of Grade III carbon steel, zinc plated, MSME tested for performance test and shall be opened at impact load of 22 Kg and more, the spring hidden in the pipe shall be expanded upto 1 meter, including taking down existing fan & down rod and refixing the fan with new smart fan rod, making all electric connections and cleaning of fan after installation and testing, complete as specified and directed. | 2,400 | Each Job | - | - |
| 9 | Supply and installation of Anti Suicide Fan Down Rod (smart fan rod), length 380mm (15"), white MS pipe, zinc plated, and powder coated,19mm outer dia, 1.8mm (+ 0.05mm) wall thickness including in-built spring set and with a built-in paire FR connector copper wire of suitable cross section, spring set shall be of Grade III carbon steel, zinc plated, MSME tested for performance test and shall be opened at impact load of 22 Kg and more, the spring hidden in the pipe shall be expanded upto 1 meter, including taking down existing fan & down rod and refixing the fan with new smart fan rod, making all electric connections and cleaning of fan after installation and testing, complete as specified and directed. | 900 | Each Job | - | - |
| 10 | S&F in replacement twin twisted 2 core flexible copper cable of size 1 Sqmm from ceiling rose to fan etc and connections, complete as specified and directed. | 2,000 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.17 MB
BOQ_882420.xls
BOQ • 0.28 MB
Tender8128.pdf
Tender Documents • 0.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .