Loading…
Loading…
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
7 Sept 2026, 5:00 pm
Executive Engineer MID Shadipora
shadipora
LIS Shalteng Providing and fitting of 30 Cusec Vertical Pumping Unit along with Starters Cables etc.
2026_IFC_322404_2
e NIIT No 9 of 2026-27
Open Tender
Pumps/Motors
Percentage
90 days
shadipora
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Ex. Engineer MID Shadipora
₹80,000
Yes
26 Aug 2026
26 Aug 2026
8 Sept 2026
26 Aug 2026
7 Sept 2026
26 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design, Manufacture, Supply, installation, testing & commissioning of Vertical Turbine pump motor unit of specified duty parameters with specified capacity vertical solid shaft TEFC squirrel cage induction motor of following Specifications:
i) Type Vertical Turbine, Mixed Flow Pump ia) Make: Kirloskar/WILO/Flowmore/WPIL or Equivalent as approved in EOMs List issued by Superintending Engineer Mechanical Circle I&F Dept. Srinagar. ii) Discharge of pump: 30 cusec (3058 m3/hr) iii)Dynamic Head: 7.00 m iv) Rated Speed: Suitable for the guaranteed duty point not exceeding 1000 RPM
v) Pump Efficiency: Not less than 80 % at the guaranteed rated duty point. vi) Fluid to be handled: Raw Water River vii) No. of stages: Single viii) Duty: Continuous
ix) Column pipe size 500mm ND or as required as per discharge and design x) Overall length of Column pipe along with Bell mouth, diffuser and Discharge Bend: 7.86 m
xi) Location of Discharge Elbow: Below Machine Floor Level
Material of construction
Casing: Cast Iron FG260
Impeller: Stainless steel SS410
Bowl & Suction Bell: Cast Iron FG260
Shaft/ Shaft coupling: AISI 410 Stainless Steel
Shaft Sleeve: AISI 410 Stainless Steel
Column Pipe: MS ERW (Min.thickness 8mm)
Base Plate: MS
Suction Strainer: SS
Motor specifications:
i)Rating of motor: Motor rating shall be adequate for the max power absorbed by the pump over the specified operating range and shall not be Less than 110 HP, and the motor shall not overload at any point within the specified operating range .ii)Frequency: 50± Hz iii)Phase Three phase
iv)Voltage: 415±10%
v)Efficiency: Minimum IE2
vi) Insulation Class: F or above
vii) Enclosure: TEFC
VIII) RPM: Not exceeding 1000 The Job includes fabrication and fitting of foundation/ support structure using requisite ISMB beams, channels, chequered plate as per site requiremnets for fixing of sole plate etc including commissioning at site and the testing at full load. The Job shall also include any modifictions required for proper fitting/alignment of the pumping unit with the existing delivery line. | 1 | Job | 35,00,000 | ₹35,00,000 |
| 2 | Providing, installation, testing and commissioning of 120 Sq mm, single core, PVC insulated, un-armoured copper LT power cable confirming to ISI Standards. The cable shall be multi stranded, having sequential marking on outer sheath. Acceptable make shall be Finolex/ L&T/ Havells/ Gloster/KEI/ Polycab or equivalent. | 55 | Mtrs | 3,250 | ₹1,78,750 |
| 3 | Supply, Installation Testing and Commissioning at site 125 HP Cubical and pedestal type Fully automatic Star Delta starter. The starter shall comprise of the following equipment and accessories.
a) Main Contactor Assembly 225 Amp AC3 (01 No).
b) Delta Contactor Assembly 225 Amp AC3 (01 No).
c) Star Contactor Assembly 140 amp AC3 (01 NO)
d) Thermal overload Relay of with 132–220-amp Relay range.
e) Double vacuum timer assembly having time range of 0-60/sec.
f) Single phase preventer.
g) Auxiliary fuse units of suitable Ampere range.
h) Electrolytic Copper bus bar strips of suitable size of duly tinned air insulated mounted on suitable size backlit insulators.
i) 01 no 3 Phase Digital Ampere meter which indicate 0 to 300 Ampere amperage with required attachments.
j) One number 3 Phase Digital voltmeter 0-500 volts.
k) On/Off push button Switch’s.
l) Complete internal wiring of the Control panel for operation of the equipment by using adequate capacity of Single/Multi strand copper wire of standard make. The wiring shall be provided with plastic washers for identification of each wire at various joints. The wiring shall have to complete properly.
m) Main 3 Pole MCCB of Suitable Rating. (01 no)
n) Cubical Panel fabricated out of 1.5/2.0mm CRCA Sheet with angle 40x5 mm
The job further includes P/F of 120 Sq.mm Single core multistrand, PVC insulated copper cable (20mts) with proper thumbing for connecting Starter with the existing electrical circuit/system. | 1 | Job | 3,20,000 | ₹3,20,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.73 MB
BOQ_1080412.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].